Location via proxy:   [ UP ]  
[Report a bug]   [Manage cookies]                

Omnigrad TST410: RTD Thermometer

Download as pdf or txt
Download as pdf or txt
You are on page 1of 4

Technical Information

TI066T/02/en
RTD Thermometer
No. 58004732
omnigrad TST410
Medium duty - Mignon head
Ø 3 mm M.I. probe
requiring compression fitting

foto

Description Application
TST410 RTD thermometer assembly Typical applications for TST410 sensor
includes a single Pt100 probe in mineral are pressure-less systems such as air
insulated cable, 3 or 4 wire connections, ducts, flues and pipelines.
with 3 mm stem diameter, a mignon Special care should be given to the
terminal head and an optional maximum allowed temperature
compression fitting. surrounding the terminal head, which
must be lower than 80°C.
omnigrad TST410

Technical data
Probe Sensing element: Platinum resistance, 1 Pt100 Ω at 0°C, standard version
Tolerances: class A or class B to IEC 751
Wiring: 3 or 4 wire connections
Insulation resistance: ≥ 100 MΩ , test voltage 250 V at ambient temperature
Electrical connections: terminal block
Stem: mineral insulated cable (MgO)
Sheath: AISI 316L/W.1.4404
Standard diameter: 3 mm
Operating temperature: -50 ... +400 °C
Response time values: according to IEC751, in moving water at 0.4 m/s
T50 = 3 s; T90 = 6 s
Process connection: optional TA50 threaded compression fitting

TA20L terminal head Dimension: Mignon type


Protection grade: IP 67
Max. temperature: 80°C
Material: light alloy dye casting with rubber gasket under the cover
Cable connection: PG9
Thermowell entry: M10 x 1 mm
Body colour: blue according to RAL5012 - epoxy coated
Cap colour: grey according to RAL7015 - epoxy coated
Weight: 75 g

Mounting accessories TA50 Threaded


Compression Fitting: d = 3 mm ; D = G 1/4"
Sealing ring Teflon: Tmax 200°C; Pmax 10 bar (at 20°C)
Sealing ring in W.1.4404: Tmax 400°C; Pmax 40 bar (at 20°C)

Intallation - The allowed bending radius R for mineral insulated cables is ≥ 15 mm for 3 mm diameters
Bending radius (DIN 43721). The not bendable length is ~30 mm.

2 Endress+Hauser
omnigrad TST410

Order key
• For a correct temperature TST410- RTD THERMOMETER - Medium duty - Mignon head
measurement the thermometer Ø 3mm M.I. probe - Requiring separate compression fitting
immersion length must be 20 times
the probe diameter in order to Insertion length L (50-5000mm)
eliminate thermal drift due to A 50 mm insertion length L
process connection heat
dissipation. Shorther immersion B 100 mm insertion length L
length can be supplied but the C 200 mm insertion length L
thermometer requires an external D 300 mm insertion length L
(process connection and E 400 mm insertion length L
connection head) thermal F 500 mm insertion length L
insulation. X mm insertion length to spec.
Y mm special insertion length
Price for 100 mm length L
55 2 3mm=D inset
9 To specification
Installation
AA Compression fitting not included
FB Compr. fitting TA50 with SS316 sleeve
55

FP Compr. fitting TA50 with PTFE sleeve


YY To specification
Class and type of inset
1B3 1 Pt100 class B, 3 wire
1B4 1 Pt100 class B, 4 wire
1A3 1 Pt100 class A, 3 wire
1A4 1 Pt100 class A, 4 wire
9Y9 RTD class and type to specification
L

TST410- Complete Order Code

Ø3

Endress+Hauser 3
Supplementary • Technical Information TA20 terminal heads (TI 072T/02/en)
Documentation • Technical Information TA fittings (TI 091T/02/en)

Endress+Hauser
Gmbh+Co.
Instruments International
P.O. Box 2222
D-79574 Weil am Rhein
Germany

Tel. (07621) 975-02


Tx 773926
Fax (07621) 975 345
http://www.endress.com
info@ii.endress.com

TI 066T/02/en/04.01
FM+SGML 6.0

You might also like