Spreader Bar Calculation Instr
Spreader Bar Calculation Instr
Spreader Bar Calculation Instr
Description: Date:
Endcap Deduction Length: 12,00 in Sling Type: 1-Part Mechanical Spliced IWRC (EIPS,
6X19)
Link Plate & Endcap Weight: 125,00 Lbf Sling Configuration: Vertical Basket
Pipe Wall Thickness: 0,465 in Weight Per Linear Foot: 43,40 Lbf/ft
Pipe Axial Stress: 3,51 ksi < 7,40 ksi Allowed Axial Stress
Pipe Bending Stress: 2,02 ksi < 11,67 ksi Allowed Bending Stress
1
SMART Rigger Software LLC
Combined Stress (ASME-BTH-1, Eq 3.33): 47,4 % Limit (d/t) Ratio Axial Compress: 91.14
Top Sling Loading: 43,25 Ton Top Shackle Load: 43,25 Ton
Top Sling Capacity: NaN Ton Top Shackle Capacity: 60,61 Ton
Top Sling Percent Capacity: NaN % Top Shackle Percent Capacity: 71,36 %
Sling Bending (D/d) Efficiency: 100,00 % Bottom Shackle Load: 37,52 Ton
Vertical Height from Centerline of Pipe to Hook: 22,65 ft Sling Angle: 61,11 Deg
998,2 Lbf
Spreader Bar Pipe Weight:
Total Top Shackle Weight: 136,0 Lbf
2
SMART Rigger Software LLC
22,65 ft
55 X Wide Body
SWL: 60,61 Ton
Tension: 43,25 Ton
Percent Capacity: 71,36 %
61,11 Deg
25,00 ft
Note:
RED Text Indicates Failure
General Representative Layout: Picture is not Geometric Scale, Slings
and Shackles are Representative Only, See Selection and Descriptions
All reported sling capacities must be verified by sling manufacture for the specific lift configuration. Endcap and Link plate capacities are not
calculated and must be confirmed sufficient for use per ASME-BTH-1 lifting code by a qualified person. Spreader Bar calculations are based on
inline compression force with center line of pipe, without any other external forces applied or considered. Pipe is considered straight without
holes and defect free. Results and the application there of must be confirmed for use by a qualified person.