South Pacific Lighting Plot
South Pacific Lighting Plot
South Pacific Lighting Plot
THTR
High End SolaSpot 1000 12
1000
Elation Artiste Picasso 2
0 0
CHAUVET R2 WASH 22
CL
Venue
LS # Trim Deck D' to PL Description
ETC S4-26° LED Lustr•S2 32
46 0'-0" 38'-9 1/2"
45 0'-0" 38'-1 1/2"
ETC S4-36° LED Lustr•S2 16
1 44
43
0'-0"
0'-0"
37'-5 1/2"
36'-9 1/2" FULL STAGE BLACK 1
BOUNCE 42 0'-0" 36'-1 1/2" WHITE BOUNCE ETC S4-50 LED Lustr•S2 16
41 0'-0" 35'-5 1/2"
MIRROR
MIRROR
14 13 12 11 10 9 8 7 6 5 4 3 2 1 33 28'-0" 27'-5 1/2" #5 ELECTRIC
ETC ColorSource PAR-MR 38
2 32 0'-0" 26'-1 1/2"
2
31 0'-0" 25'-5 1/2" ETC ColorSource PAR-WO• 4
530 531 532 SAND DUNE
16 17 18 19 20 30 0'-0" 24'-9 1/2"
509 510 511 512 24 0'-0" 18'-9 1/2" [ORCH SHELL #2 - NOT USED]
NOTE : PIPE NEEDS
527 528 529
1000
11 12
1000
13
1000
14 15
1000
TO BREAST US 1'-4"
#3 ELEC 28 27 26 25 24 23 22 21 20 19 18 17 16 15 14 13 12 11 10 9 8 7 6 5 4 3 2 1 #3 ELEC 23 29'-0" 17'-5 1/2" #2
#3BLACK
ELECTRIC
LEGS
GENERAL NOTES
334 27 28 29 47 48 49 338
592 22 0'-0" 16'-9 1/2"
NOTE : FIXTURE 324 111 112 113 114 115 328 NOTE : FIXTURE - Please have ample R119, R132, and blackwrap
3 TAILS DOWN FROM
ELECTRIC 2'-0"
ACT 2 MAP
TAILS DOWN FROM
ELECTRIC 2'-0"
21
20
0'-0"
0'-0"
16'-1 1/2"
15'-5 1/2" MAP [ACT 2]
3 available at focus call.
TEMP
LS = Line Set TEMPLATE
GP = Ground Plan
4 501
1 521 2
502
3 522
504
4 523 5
503 #2 BLIND PORTAL 8
7
0'-0"
0'-0"
5'-5 1/2"
4'-9 1/2"
#2 PORTAL / BLINDS
4 LX = Electric
TD = Tech. Direct.
UNIT # U#
1000 1000 1000 1000
LD = Lighting Dsgnr
#1 ELEC 22 21 20 19 18 17 16 15 14 13 12 11 10 9 8 7 6 5 4 3 2 1 #1 ELEC 6 29'-0" 4'-1 1/2" #1 ELECTRIC
332 21 22 23 41 42 43 336 CHANNEL #
5 0'-0" 3'-5 1/2"
NOTE : FIXTURE 322 326 NOTE : FIXTURE
TAILS DOWN FROM SHOW DROP #2 TAILS DOWN FROM 4 0'-0" 1'-1 1/2" #2 SHOW DROP
ELECTRIC 2'-0" SHOW DROP #1 ELECTRIC 2'-0" 3 0'-0" 2'-1 1/2" #1 SHOW DROP
2 0'-0" 1'-1 1/2" MAIN CURTAIN
#1 BLIND PORTAL
PL PL
1 0'-0" 0'-9 1/2" HOUSE VALENCE + #1 PORTAL
321 325
CL
5 5
http://www.mikewoodld.com
mike@mikewoodld.com
813-716-1909 Cell / 646-694-8656 Studio
3161 Broadway #2C - New York, NY 10027
HS LADDER - R HS LADDER - L This drawing contains a visual concept and construction suggestions.
The lighting designer and design assistants/associates are not qualified
to determine or guarantee the structural integrity or appropriateness of
any construction or rigging methods, and assume no liability or
responsibility for the improper engineering, construction, or use of any
and all designs contained on this document and elsewhere throughout
the production. Always consult a licensed structural engineer before any
rigging or construction takes place. All applicable local and national fire
and life safety codes must be follwed at all times.
REVISION HISTORY
NO. REVISION DATE BY
A01 Document Prep 31 JAN 19 JLC
A02 Rough Submit 13 FEB 19 JLC
B01 Final Submit 19 FEB 19 JLC
6 6
SOUTH PACIFIC
PRODUCTION STAFF
DIRECTOR . . . . . . . . . . . . . . . . . . . . . . BAAYORK LEE
LIGHTING DESIGNER . . . . . . . . . . . . . . .MIKE WOOD
ASSOC LIGHTING DSGNRS . . . .DALTON HAMILTON
ABBY MAY
DWG NUMBER
SCALE 1/4" = 1'0"
1
UNLESS OTHERWISE NOTED
PG SIZE ARCH D
OF 5
LIGHT PLOT
A B C D E F G H I J OVERHEADS
A B C PL D E F G PL H I J KEY TO INSTRUMENTATION
THTR
APRON PIPE 2 1 APRON PIPE
321 325
1000
Elation Artiste Picasso 2
0 0
CHAUVET R2 WASH 22
HS LADDER - R HS LADDER - L
ETC Source-4 10° 6
GENERAL NOTES
BOX 2R - HI BOX 2R - LOW BOX 2L - LOW BOX 2L - HI - Please have ample R119, R132, and blackwrap
3 3 available at focus call.
TEMP
#1 FOH DS #1 FOH DS LS = Line Set TEMPLATE
GP = Ground Plan
4 4 LX = Electric
TD = Tech. Direct.
UNIT # U#
LD = Lighting Dsgnr
BOX 3L - LOW BOX 3L - HI
BOX 3R - HI BOX 3R - LOW CHANNEL #
CL
5 5
http://www.mikewoodld.com
mike@mikewoodld.com
813-716-1909 Cell / 646-694-8656 Studio
3161 Broadway #2C - New York, NY 10027
#2 FOH 11 9 7 6 5 3 1 #2 FOH This drawing contains a visual concept and construction suggestions.
10 8 4 2 The lighting designer and design assistants/associates are not qualified
to determine or guarantee the structural integrity or appropriateness of
THTR THTR THTR any construction or rigging methods, and assume no liability or
THTR THTR THTR responsibility for the improper engineering, construction, or use of any
101 554 102 555 103 104 556 105 and all designs contained on this document and elsewhere throughout
551 552 553 the production. Always consult a licensed structural engineer before any
rigging or construction takes place. All applicable local and national fire
and life safety codes must be follwed at all times.
REVISION HISTORY
NO. REVISION DATE BY
A01 Document Prep 31 JAN 19 JLC
A02 Rough Submit 13 FEB 19 JLC
B01 Final Submit 19 FEB 19 JLC
6 6
8 1
7 2
561 6 3 563
351
711
5
711
4
712
712
352 SOUTH PACIFIC
PRODUCTION STAFF
DIRECTOR . . . . . . . . . . . . . . . . . . . . . . BAAYORK LEE
FOLLOWSPOT #1 FOLLOWSPOT #2 LIGHTING DESIGNER . . . . . . . . . . . . . . .MIKE WOOD
ASSOC LIGHTING DSGNRS . . . .DALTON HAMILTON
ABBY MAY
DWG NUMBER
SCALE 1/4" = 1'0"
2
UNLESS OTHERWISE NOTED
FOLLOWSPOTS
FOLLOWSPOTS PG SIZE ARCH D
NOTE: NOT DRAWN IN ACTUAL LOCATION. OF 5
PLEASE SEE SECTION FOR MORE INFORMATION.
FOLLOWSPOTS ARE ROBERT JULIAT SUPER KORRIGAN 1200W HMI UNITS.
LIGHT PLOT
A B C D E F G H I J FRONT OF HOUSE
A B C D E F G H I J KEY TO INSTRUMENTATION
THTR
High End SolaSpot 1000 12
1000
TBD TBD TBD TBD TBD TBD TBD
7 6 5 4 3 2 1 #5 BOOM SR #5 BOOM SL 7 6 5 4 3 2 1 Elation Artiste Picasso 2
0 261 271 262 272 263 273 264
28'-0" FROM C/L 28'-0" FROM C/L
TBD 268 TBD 276 TBD 267 TBD 275 TBD 266 TBD 274 TBD 265 0
34'-6" FROM P/L 34'-6" FROM P/L CHAUVET R2 WASH 22
2 4 6 8 8 6 4 2
ETC S4 Fresnel Lustr•S2 8
R09 R09 R09 #3 LADDER SR #3 LADDER SL
N/C
N/C
N/C 544 9 9 548 N/C R132 R132 R132
1 3 5 7 26'-0" FROM C/L 26'-0" FROM C/L
7 5 3 1 Ovation E260 WW 14° 6
229 228 227 205 18'-0" FROM P/L 18'-0" FROM P/L
N/C 211 L161 239 L161 238 L161 237
9'-3" DECK TO BOTTOM RUNG 9'-3" DECK TO BOTTOM RUNG Ovation E260 36° 8
N/C
9 547 N/C R132 R132 R132
1 3 5 7 26'-0" FROM C/L
7 5 3 1 GENERAL NOTES
26'-0" FROM C/L
226 225 224 203 9'-0" FROM P/L 9'-0" FROM P/L
N/C 209 L161 236 L161 235 L161 234 - Please have ample R119, R132, and blackwrap
3 9'-3" DECK TO BOTTOM RUNG 9'-3" DECK TO BOTTOM RUNG 3 available at focus call.
TEMP
LS = Line Set TEMPLATE
GP = Ground Plan
4 4 LX = Electric
TD = Tech. Direct.
UNIT # U#
N/C 542 9
N/C
9 546 N/C R132 R132 R132
1 3 5 7 26'-0" FROM C/L 26'-0" FROM C/L
7 5 3 1
223 222 221 201 3'-0" FROM P/L 3'-0" FROM P/L
N/C 207 L161 233 L161 232 L161 231
9'-3" DECK TO BOTTOM RUNG 9'-3" DECK TO BOTTOM RUNG
N/C R132
5 1 2 #1 BOOM SR #1 BOOM SL 2 1 5
CL
241 251 R132 255 N/C 245 http://www.mikewoodld.com
23'-6" FROM C/L 23'-6" FROM C/L mike@mikewoodld.com
813-716-1909 Cell / 646-694-8656 Studio
-12" FROM P/L -12" FROM P/L 3161 Broadway #2C - New York, NY 10027
PL PL
This drawing contains a visual concept and construction suggestions.
The lighting designer and design assistants/associates are not qualified
to determine or guarantee the structural integrity or appropriateness of
any construction or rigging methods, and assume no liability or
responsibility for the improper engineering, construction, or use of any
and all designs contained on this document and elsewhere throughout
the production. Always consult a licensed structural engineer before any
rigging or construction takes place. All applicable local and national fire
and life safety codes must be follwed at all times.
REVISION HISTORY
NO. REVISION DATE BY
PROSCENIUM PROSCENIUM
A01 Document Prep 31 JAN 19 JLC
A02 Rough Submit 13 FEB 19 JLC
B01 Final Submit 19 FEB 19 JLC
US
US
6 6
3
UNLESS OTHERWISE NOTED
DS
DS
PG SIZE ARCH D
OF 5
LIGHT PLOT
A B C D E F G H I J BOOM + LADDER BUILD
A B C D E
L F G H I J KEY TO INSTRUMENTATION
THTR
BOUNCE
7 6 5 4 3 2 1 GROUND ROW
High End SolaSpot 1000 12
1000
311 312 313 314 315 316 317
#5 BOOM SR #5 BOOM SL
Elation Artiste Picasso 2
0 ACT 1 TRANSLUCENCY--BALI HAI
0
CHAUVET R2 WASH 22
ACT 2 TRANSLUCENCY--STORM
ETC Source-4 10° 6
BLACK SCRIM
ETC S4-19°LED Lustr•S2 18
#5 BLIND BORDER
GROUND ROW ETC S4-26° LED Lustr•S2 32
MIRROR
MIRROR
ETC S4-36° LED Lustr•S2 16
1 1
ETC S4-50 LED Lustr•S2 16
#2 LADDER SR #2 LADDER SL
DS BLINDS LEGEND
ABBREVIATIONS: FOCUS FOC
R = Rosco COLOR CLR
G = GAM
A = Apollo LENSº
#2 BOOM SR #2 BOOM SL
TEMP
LS = Line Set
HANGING LAMP [S?]
TEMPLATE
GP = Ground Plan
4 Production reports there are [2] hanging #2 BLIND PORTAL 4 LX = Electric
TD = Tech. Direct.
UNIT # U#
#1 BLIND PORTAL
PL PL
#1 BOOM SR #1 BOOM SL
5 5
http://www.mikewoodld.com
mike@mikewoodld.com
813-716-1909 Cell / 646-694-8656 Studio
CL
3161 Broadway #2C - New York, NY 10027
SOUTH PACIFIC
PRODUCTION STAFF
FOOTLIGHTS 5 1
FOOTLIGHTS DIRECTOR . . . . . . . . . . . . . . . . . . . . . . BAAYORK LEE
LIGHTING DESIGNER . . . . . . . . . . . . . . .MIKE WOOD
701 704 ASSOC LIGHTING DSGNRS . . . .DALTON HAMILTON
ABBY MAY
DWG NUMBER
702 703 SCALE 1/4" = 1'0"
3/8"
4
UNLESS OTHERWISE NOTED
PG SIZE ARCH D
OF 5
LIGHT PLOT
A B C D E F G H I J DECK LAYOUT + SET ELECTRICS
A B C D E F G H I J KEY TO INSTRUMENTATION
THTR
High End SolaSpot 1000 12
1000
Elation Artiste Picasso 2
0 0
CHAUVET R2 WASH 22
xx
ETC S4-PAR (MFL) 16
Stormy Strobe 2
#2 FOH
HOUSE VALENCE + #1 PORTAL
[ORCH SHELL #3 - NOT USED]
FOLLOWSPOTS
#4 PORTALS / BLINDS
#3 PORTAL / BLINDS
#2 PORTAL / BLINDS
FULL STAGE BLACK
DUBEQUE FACADE
#5 BLIND BORDER
HANGING BLINDS
DS BLINDS #2, #4
DS BLINDS #1, #5
WHITE BOUNCE
LEGS
#2 SHOW DROP
#1 SHOW DROP
STORM [ACT 2]
MAIN CURTAIN
BLACK SCRIM
DS BLINDS #3
#6 ELECTRIC
#5 ELECTRIC
#4 ELECTRIC
ELECTRIC
#2 ELECTRIC
#1 ELECTRIC
MAP [ACT 2]
MAP [ACT 1]
Description
Plaster Line
FOLIAGE
GENERAL NOTES
#1 FOH
#3BLACK
33'-5 1/2"
32'-9 1/2"
30'-9 1/2"
29'-5 1/2"
28'-9 1/2"
28'-1 1/2"
27'-5 1/2"
26'-1 1/2"
25'-5 1/2"
24'-9 1/2"
24'-1 1/2"
23'-5 1/2"
22'-9 1/2"
22'-1 1/2"
20'-9 1/2"
18'-9 1/2"
17'-5 1/2"
16'-9 1/2"
16'-1 1/2"
15'-5 1/2"
14'-9 1/2"
14'-1 1/2"
13'-5 1/2"
12'-1 1/2"
11'-5 1/2"
10'-9 1/2"
10'-1 1/2"
D' to PL
9'-5 1/2"
8'-9 1/2"
8'-1 1/2"
6'-9 1/2"
5'-5 1/2"
4'-9 1/2"
4'-1 1/2"
3'-5 1/2"
1'-1 1/2"
2'-1 1/2"
1'-1 1/2"
0'-9 1/2"
0"
framed and loaded prior to focus. See Channel
Hookup and Instrument Schedule for details.
Venue
Deck
28'-0"
29'-0"
29'-0"
29'-0"
29'-0"
0'-0"
0'-0"
0'-0"
0'-0"
0'-0"
0'-0"
0'-0"
0'-0"
0'-0"
0'-0"
0'-0"
0'-0"
0'-0"
0'-0"
0'-0"
0'-0"
0'-0"
0'-0"
0'-0"
0'-0"
0'-0"
0'-0"
0'-0"
0'-0"
0'-0"
0'-0"
0'-0"
0'-0"
0'-0"
0'-0"
0'-0"
0'-0"
0'-0"
0'-0"
0'-0"
0'-0"
0'-0"
0'-0"
0'-0"
0'-0"
N/A
N/A
46
45
44
43
42
41
40
39
38
37
36
35
34
33
32
31
30
29
28
27
26
25
24
23
22
21
20
19
18
17
16
15
14
13
12
10
11
8
7
6
5
4
3
2
1
noted herein.
LEGEND
ABBREVIATIONS: FOCUS FOC
R = Rosco COLOR CLR
G = GAM
A = Apollo LENSº
TEMP
#6 ELEC
#5 ELEC
#4 ELEC
#3 ELEC
#2 ELEC
#1 ELEC
CHANNEL #
BOX 3L - HI
BOX 2L - HI
BOX 1L - HI
#3 LADDER SL
#2 LADDER SL
#1 LADDER SL
5 5
#5 BOOM SL
BALC RAIL
BOX 3L - LOW
http://www.mikewoodld.com
mike@mikewoodld.com
813-716-1909 Cell / 646-694-8656 Studio
BOX 2L - LOW
3161 Broadway #2C - New York, NY 10027
This drawing contains a visual concept and construction suggestions.
The lighting designer and design assistants/associates are not qualified
to determine or guarantee the structural integrity or appropriateness of
BOX 1L - LOW
#3 BOOM SL
#2 BOOM SL
#1 BOOM SL
REVISION HISTORY
NO. REVISION DATE BY
A01 Document Prep 31 JAN 19 JLC
A02 Rough Submit 13 FEB 19 JLC
B01 Final Submit 19 FEB 19 JLC
6 6
OPEN
SOUTH PACIFIC
PRODUCTION STAFF
DIRECTOR . . . . . . . . . . . . . . . . . . . . . . BAAYORK LEE
LIGHTING DESIGNER . . . . . . . . . . . . . . .MIKE WOOD
ASSOC LIGHTING DSGNRS . . . .DALTON HAMILTON
ABBY MAY
DWG NUMBER
SCALE 3/16"
1/4" = 1'0"
5
UNLESS OTHERWISE NOTED
PG SIZE ARCH D
OF 5
LIGHT PLOT
A B C D E F G H I J SECTION