Home Work 01 & 02
Home Work 01 & 02
Home Work 01 & 02
to 174,000 in 2000. Estimate the 2009 population by (a) Arithmetic and (b) Geometric progression.
Home Work # 1
Data
Providence ,RI
ti= 1990 Yj= 161000
tj= 2000 Yj= 174000
tm= 2009 Ym= ?
Arithmetic Population
Ym = Yj+(tm-tj)[(yj-yi)/(tj-ti)]
tm-tj 9.25
Yj-yi 13000
ti-tj 10
Ym= 186025
Geometeric Population
log(Ym) = log(Yj)+(tm-tj)[(log(Yj)-log(Yi))/(tj-ti)]
log(Yi) = 5.206826
log(Yj) = 5.240549
log(Ym) 5.271743
Ym= 186957.5
Providence, RI Population
190000 186957.5465
186025
185000
les
Providence, RI Population
190000 186957.5465
186025
185000
Number of peoples
180000
174000
175000
170000
165000
161000
160000
1990 2000 2009
Years
Problem. 02: Determine the UBOD and BOD5 (in mg/L) of a mixture of 150 mg/L of Glutamine
(C5H10N2O3) and Glucose (C6H12O6). Assume the value of BOD5 first-order reaction rate
constant is 0.23/d (base e).
Data:
Reactions Equation
C5H10N2O3 + 4.5O2 → 5CO2 + 2NH3 + 2H2O ….(1
146 144 220 34 36
Sol:
UBOD = 307.945
BODt= UBOD(1-e-kt)
UBOD = 307.945
t= 5
k= 0.23
e= 2.718
BOD5= 210.4267
Problem.03: The total suspended solids for a wastewater sample was found to be 175 mg/L.
If the following test result was obtained, determine the size of sample used in the analysis.
Data
Mass of glass fibre filter = 1.5244
Mass of glass fibre filter plus residue after drying at 105 = 1.5953
TSS 175 mg/L 0.175
Volume of sample ?
Sol:
TSS = (Mass of glass fibre filter plus residue after drying -mass of fibre filter)/Sample size,L
Size of Sample, L = (Mass of glass fibre filter plus residue after drying -mass of fibre filter)/TSS
Problem.1:Your boss has assigned you the job of designing a rapid-mix tank for the new water
treatment plant for treatment plant for the town of Waffle.The design flow rate is 0.050 m3 /s. The
average water temperature is 8 C. The following design assumptions for a rapid-mix tank have
been made:
1. Number of tanks 1 (with 1 backup) N= 1
2. Tank configuration: circular with liquid depth_x0001_ 1.0 m d= 1
3. Detention time 5 s t= 5
4. Velocity gradient 750 s 1 G= 750
5. Impeller type: turbine, 6 flat blades,Np 3.6 Np = 3.6
6. Available impeller diameters: 0.25, 0.50, and 1.0 0.25 0.5
7. AssumeB_x0001_ (1/3)H
8. Design flow rate is 0.050 m³ /s. Q= 0.05
9. The average water temperature is 8 C T= 8
V= 0.05*5
V= 0.025
Step#02:
Using the radial impeller guidance fromTable 6-5, assumeH /T= 2.0, that isH= 2T
For a round mixing tank
T= ((4*0.25)/(2*π))^(1/3)
T= 0.542018 m
H=2T
H= 1.084035 m
B=1/3*H
B= 0.361345 m
Step#03:
The required input water power can be calculated by using Equation 6-12. Using Table
A-1 in Appendix A and the temperature of the water, find μ =1.307x 10¯³ Pa · s.
μ= 0.001307
p= 183.7969 W
Because the efficiency of transfer of motor power to water power is about 80%, the
motor power should be
P= 83.8/0.8 229.7461 W
Step#04:
Using Table 6-5 , evaluate the different size radial impellers using the geometric ratios.
Below is a comparison of the ratios for the available sizes of radial impellers and the
rapid mix basin dimensions.
Step#05:
The rotational speed is calculated by solvingEquation 6-17 for n:
n= 1.1777737 RPS
N= 70.666424 RPM
Design Parameters
Volume of rapid mixing tank (V) = (m³) 0.25
Impeller Diameter (D) = (meter) 0.5
Impeller equivelent diameter(T) = (meter) 0.542018
Water depth (H) = (meter) 1.084035
Water depth below the impeller (B) = (meter) 0.361345
Required input water power (P) = (watt) 229.74
rotational speed (n) = (rpm) 70.67
Problem.2: Continuing the preparation of the proposal for the Waffle treatment plant ( Prob
design the flocculation tank by providing the following for the first two compartments on
Sol:
Step#01:
determine the volume of rapid mixing tank
V= 0.05*30*60 m³
V= 90
Step#02:
Using the radial impeller guidance fromTable 6-5, assumeH /T= 1.5, that isH= 1.5T
For a round mixing tank
T= ((4*90)/(2*π))^(1/3)
T= 3.8557981 m
H=1.5T
H= 5.7836972 m
B=1/3*H
B= 1.9278991 m
Step#03:
The required input water power can be calculated by using Equation 6
A-1 in Appendix A and the temperature of the water, find μ =1.307x 10¯³ Pa · s.
μ= 0.001307 Pa · s.
At G = 60 sec¯¹
P= 423.468
Because the efficiency of transfer of motor power to water power is about 80%, the
motor power should be
P= 423.4/0.8 529.335 W
At G = 50 sec¯¹
Because the efficiency of transfer of motor power to water power is about 80%, the
motor power should be
P= 294.07/0.8 367.5938 W
At G = 20 sec¯¹
P= 47.052 W
Because the efficiency of transfer of motor power to water power is about 80%, the
motor power should be
P= 47.05/0.8 58.815 W
Step#04:
Using Table 6-5 , evaluate the different size radial impellers using the geometric ratios.
Below is a comparison of the ratios for the available sizes of radial impellers and the
rapid mix basin dimensions.
Allowable range
Geometric ratio Allowable range 1 1.5 1.5
D/T 0.14 – 0.5 0.25935 0.389025 0.389025
H/D 2–4 5.783697 3.855798 3.855798
H/T 0.28–2 1.5 1.5 1.5
B/D 0.7–1.6 1.927899 1.285266 1.285266
Although the 1.5 m diameter impeller has aD /Tslightly larger than the allowable range,
it is satisfactory in all the other aspects and, therefore, is selected.
Step#05:
The rotational speed is calculated by solvingEquation 6-17 for n:
at P= 529.3 W
n= 0.545258 rps
n= 32.71547 RPM
At P= 0.482852 rps
n= 28.97115 RPM
At P=
n= 0.262133 rps
n= 15.72796 RPM
Design Parameters
Values of velocity gradients (G) = (sec¯¹) 60 50 20
Volume of rapid mixing tank (V) = (m³) 90 90 90
Impeller Diameter (D) = (meter) 1.5 1.5 1.5
Impeller equivelent diameter(T) = (meter) 3.8557 3.8557 3.8557
Water depth (H) = (meter) 5.7836 5.7836 5.7836
Water depth below the impeller (B) = (meter) 1.9278 1.9278 1.9278
Required input water power (P) = (watt) 294.07 367.59 58.815
rotational speed (n) = (rpm) 32.17 28.97 15.72
186957.5465
186025
186957.5465
186025