Problem:01 The April census population of Providence, RI, was 161 ,000 in 1990 and decreased

to 174,000 in 2000. Estimate the 2009 population by (a) Arithmetic and (b) Geometric progression.

Home Work # 1
Data
Providence ,RI
ti= 1990 Yj= 161000
tj= 2000 Yj= 174000
tm= 2009 Ym= ?

Arithmetic Population

Ym = Yj+(tm-tj)[(yj-yi)/(tj-ti)]

tm-tj 9.25
Yj-yi 13000
ti-tj 10

Ym= 186025

Geometeric Population

log(Ym) = log(Yj)+(tm-tj)[(log(Yj)-log(Yi))/(tj-ti)]

log(Yi) = 5.206826
log(Yj) = 5.240549

log(Ym) 5.271743
Ym= 186957.5

Year Arathematic Population Geometric Population


1990 161000 161000
2000 174000 174000
2009 186957.546480748 186957.546480748

Providence, RI Population
190000 186957.5465
186025
185000
les
Providence, RI Population
190000 186957.5465
186025
185000

Number of peoples
180000
174000
175000
170000
165000
161000
160000
1990 2000 2009
Years

Column G Column H Column G Column H Column G


Column H Column G Column H Column G Column H
Column E Column C Column F

Problem. 02: Determine the UBOD and BOD5 (in mg/L) of a mixture of 150 mg/L of Glutamine
(C5H10N2O3) and Glucose (C6H12O6). Assume the value of BOD5 first-order reaction rate
constant is 0.23/d (base e).

Data:

Reactions Equation
C5H10N2O3 + 4.5O2 → 5CO2 + 2NH3 + 2H2O ….(1
146 144 220 34 36

C6H12O6 + 6O2 → 6CO2 + 6H2O


180 192 264 108 ….(2

Sol:

Oxygen required for 150 mg/L of C5H10N2O3 = 147.945 mg

Oxygen required for 150 mg/L of C6H12O6 = 160 mg

UBOD = 307.945

BODt= UBOD(1-e-kt)

UBOD = 307.945
t= 5
k= 0.23
e= 2.718

BOD5= 210.4267

Problem.03: The total suspended solids for a wastewater sample was found to be 175 mg/L.
If the following test result was obtained, determine the size of sample used in the analysis.

Total mass of glass fiber filter = 1.5244 g


Mass of glass fiber filter plus reside after drying at 105oC =1.5953 g

Data
Mass of glass fibre filter = 1.5244
Mass of glass fibre filter plus residue after drying at 105 = 1.5953
TSS 175 mg/L 0.175
Volume of sample ?

Sol:
TSS = (Mass of glass fibre filter plus residue after drying -mass of fibre filter)/Sample size,L

Size of Sample, L = (Mass of glass fibre filter plus residue after drying -mass of fibre filter)/TSS

Size of Sample = 0.405143 L

Home Work No.02

Problem.1:Your boss has assigned you the job of designing a rapid-mix tank for the new water
treatment plant for treatment plant for the town of Waffle.The design flow rate is 0.050 m3 /s. The
average water temperature is 8 C. The following design assumptions for a rapid-mix tank have
been made:
1. Number of tanks 1 (with 1 backup) N= 1
2. Tank configuration: circular with liquid depth_x0001_ 1.0 m d= 1
3. Detention time 5 s t= 5
4. Velocity gradient 750 s 1 G= 750
5. Impeller type: turbine, 6 flat blades,Np 3.6 Np = 3.6
6. Available impeller diameters: 0.25, 0.50, and 1.0 0.25 0.5
7. AssumeB_x0001_ (1/3)H
8. Design flow rate is 0.050 m³ /s. Q= 0.05
9. The average water temperature is 8 C T= 8

Design the rapid-mix system by providing the following:

1. Water power input in kW


2. Tank dimensions in m
3. Diameter of the impeller in m
4. Rotational speed of impeller in rpm

Step#01: determine the volume of rapid mixing tank

V= 0.05*5

V= 0.025

Step#02:
Using the radial impeller guidance fromTable 6-5, assumeH /T= 2.0, that isH= 2T
For a round mixing tank
T= ((4*0.25)/(2*π))^(1/3)

T= 0.542018 m

H=2T

H= 1.084035 m

B=1/3*H

B= 0.361345 m
Step#03:
The required input water power can be calculated by using Equation 6-12. Using Table
A-1 in Appendix A and the temperature of the water, find μ =1.307x 10¯³ Pa · s.

μ= 0.001307

p= 183.7969 W

Because the efficiency of transfer of motor power to water power is about 80%, the
motor power should be

P= 83.8/0.8 229.7461 W

Step#04:
Using Table 6-5 , evaluate the different size radial impellers using the geometric ratios.
Below is a comparison of the ratios for the available sizes of radial impellers and the
rapid mix basin dimensions.

Geometric ratio Allowable range Allowable range


0.25 0.5 1
D/T 0.14 – 0.5 0.46124 0.922479 1.844958
H/D 2–4 4.336141 2.168071 1.084035
H/T 0.28–2 2 2 2
B/D 0.7–1.6 1.44538 0.72269 0.361345

Step#05:
The rotational speed is calculated by solvingEquation 6-17 for n:

n= 1.1777737 RPS

N= 70.666424 RPM

Design Parameters
Volume of rapid mixing tank (V) = (m³) 0.25
Impeller Diameter (D) = (meter) 0.5
Impeller equivelent diameter(T) = (meter) 0.542018
Water depth (H) = (meter) 1.084035
Water depth below the impeller (B) = (meter) 0.361345
Required input water power (P) = (watt) 229.74
rotational speed (n) = (rpm) 70.67

Problem.2: Continuing the preparation of the proposal for the Waffle treatment plant ( Prob
design the flocculation tank by providing the following for the first two compartments on

1. Water power input in kW


2. Tank dimensions in m
3. Diameter of the impeller in m
4. Rotational speed of impeller in rpm

Use the following assumptions:

1. Number of tanks_x0001_ 1 (with 1 backup) N= 1


2. TaperedG in three compartments: 60, 50, and 20 sG- 1= (sec¯¹60 50
3. Detention time_x0001_ 30 min t= 30 min
4. Depth_x0001_ 3.5 m d= 3.5 m
5. Impeller type: axial-flow impeller, three blades,Np=Np =
0.43 0.43
6. Available impeller diameters: 1.0, 1.5, and 2.0 m Di = (m) 1 1.5
7. AssumeB_x0001_ (1/3)H
8. Design flow rate is 0.050 m³ /s. Q= 0.05 m³ /s
9. The average water temperature is 8 ˚C T= 8 ˚C

Sol:

Step#01:
determine the volume of rapid mixing tank

V= 0.05*30*60 m³

V= 90
Step#02:
Using the radial impeller guidance fromTable 6-5, assumeH /T= 1.5, that isH= 1.5T
For a round mixing tank

T= ((4*90)/(2*π))^(1/3)

T= 3.8557981 m

H=1.5T

H= 5.7836972 m

B=1/3*H

B= 1.9278991 m

Step#03:
The required input water power can be calculated by using Equation 6
A-1 in Appendix A and the temperature of the water, find μ =1.307x 10¯³ Pa · s.

μ= 0.001307 Pa · s.

At G = 60 sec¯¹

P= 423.468

Because the efficiency of transfer of motor power to water power is about 80%, the
motor power should be
P= 423.4/0.8 529.335 W
At G = 50 sec¯¹

motor power should be


P= 294.075 W

Because the efficiency of transfer of motor power to water power is about 80%, the
motor power should be

P= 294.07/0.8 367.5938 W

At G = 20 sec¯¹

P= 47.052 W

Because the efficiency of transfer of motor power to water power is about 80%, the
motor power should be

P= 47.05/0.8 58.815 W

Step#04:
Using Table 6-5 , evaluate the different size radial impellers using the geometric ratios.
Below is a comparison of the ratios for the available sizes of radial impellers and the
rapid mix basin dimensions.

Allowable range
Geometric ratio Allowable range 1 1.5 1.5
D/T 0.14 – 0.5 0.25935 0.389025 0.389025
H/D 2–4 5.783697 3.855798 3.855798
H/T 0.28–2 1.5 1.5 1.5
B/D 0.7–1.6 1.927899 1.285266 1.285266

Although the 1.5 m diameter impeller has aD /Tslightly larger than the allowable range,
it is satisfactory in all the other aspects and, therefore, is selected.

Step#05:
The rotational speed is calculated by solvingEquation 6-17 for n:

at P= 529.3 W

n= 0.545258 rps

n= 32.71547 RPM

At P= 0.482852 rps

n= 28.97115 RPM

At P=
n= 0.262133 rps

n= 15.72796 RPM

Design Parameters
Values of velocity gradients (G) = (sec¯¹) 60 50 20
Volume of rapid mixing tank (V) = (m³) 90 90 90
Impeller Diameter (D) = (meter) 1.5 1.5 1.5
Impeller equivelent diameter(T) = (meter) 3.8557 3.8557 3.8557
Water depth (H) = (meter) 5.7836 5.7836 5.7836
Water depth below the impeller (B) = (meter) 1.9278 1.9278 1.9278
Required input water power (P) = (watt) 294.07 367.59 58.815
rotational speed (n) = (rpm) 32.17 28.97 15.72
186957.5465
186025
186957.5465
186025

2009

Column G
Column H
g
g
g/L
L

)/Sample size,L

of fibre filter)/TSS

50 m3 /s. The
m
sec
s-¹

m³ /s
˚C
e treatment plant ( Problem 1 ),
o compartments on

20

1.5
wable range,