Zone Control Unit: Features and Functions

Download as pdf or txt
Download as pdf or txt
You are on page 1of 5

Zone Control Unit

Features and Functions


 Monitoring of up to 6 speaker circuits
(basic version)

 Connection of up to 3 amplifiers with


250 W each (basic version)

 Connection of a backup amplifier with


250 W (basic version)

 Number of speaker circuits and amplifiers


to be monitored can be expanded to an
almost unlimited amount

 The mandatory call relay of optional


volume control units of type 6 VCU can be
controlled by the zone control unit

 2 general purpose control line outputs


and 1 potential-free input per control
board

The zone control unit is used together with the INTRON-D plus communication and public address system from
INDUSTRONIC. It consists of 3 different board types which are connected via bus board in a 19" sub rack.
The digital 9 DCI 01/02 control board is the main component. The 9 DCI 01/02 controls up to 3 relay boards of the
6 DRU 03 series.
With one 6 DRU 03 relay board you can trigger up to 6 speaker circuits. In case one power amplifier fails, the relay
board switches over to a backup amplifier. In total, you can control up to 3 relay boards with one 9 DCI 01/02 control
board.
The 6 LME 01 line monitoring board monitors up to 6 speaker circuits for short circuit, earth leakage, impedance
changes and cable break. Measuring interval as well as the measuring frequency are defined via an easy-to-use
configuration software. If the value measured differs from the reference value minus the percentage you defined, a
failure message is output. In case of short circuit, the line is disconnected. If volume control units are installed in the
INTRON-D plus system, their integrated mandatory call relay can be triggered to ensure that the impedance is
measured correctly.
Free slots inside the rack can be used by other types of modules for further applications or can be covered with blind
plates.

Doc. no. DAT-304-127-500 • Rev. 4 • EN • 12.07.2016 Subject to technical modifications

© INDUSTRONIC 1/5
Modular Design
INDUSTRONIC's range of zone control units comprises several modular expansion stages and offers a high degree
of flexibility for different customer and project requirements. For the basic version, you can trigger up to 6 speaker
circuits and connect 3 amplifiers with 250 W output power each.
Furthermore, you can also integrate other boards so that the zone control unit can be expanded to up to 36 speaker
circuits and 18 250-W amplifiers for each sub rack. To implement more complex solutions you can also use several
sub racks.

The basic version for up to 6 speaker circuits and


three 250-W amplifiers consists of:
1 x 3 ZBT 01
1 x 9 DCI 01/02
1 x 6 LME 01
1 x 6 DRU 03

1 x 6 LME 01 Expansion to up to 12 speaker circuits


+ 1 x 6 DRU 03 = and six 250-W amplifiers

Expansion to up to 18 speaker circuits


+ 1 x 6 LME 01
1 x 6 DRU 03 = and nine 250-W amplifiers

The maximum expansion stage in a sub rack for


up to 36 speaker circuits and 18 250-W amplifiers
consists of:
1 x 3 ZBT 01/2
2 x 9 DCI 01/02
6 x 6 LME 01
6 x 6 DRU 03

Doc. no. DAT-304-127-500 • Rev. 4 • EN • 12.07.2016 Subject to technical modifications

© INDUSTRONIC 2/5
Components
Type 3 ZBT 01

Description 19" sub rack with 1 bus board to be equipped with the
9 DCI 01/02, 6 DRU 03 and 6 LME 01 boards

Type Number 216-340-600

Type 3 ZBT 01/2

Description 19" sub rack with 2 bus boards to be equipped with the
9 DCI 01/02, 6 DRU 03 and 6 LME 01 boards

Type Number 216-340-700

Type 9 DCI 01/02

Description Control board for zone control unit, control of up to 3 relay boards of the
6 DRU 03 series, 1 potential-free input, 2 control line outputs, LEDs to
indicate operating states and error

Type Number 9 DCI 01: 304-127-200


9 DCI 02: 304-127-300

Type 6 DRU 03

Description Relay board for zone control unit, triggering of up to 6 speaker circuits,
up to 3 relay boards per zone control unit, 3 amplifier inputs, 6 outputs
(2 per amplifier input), switch-over from power amplifier to backup
amplifier in case of failure, LEDs to indicate active speaker circuits and a
connected backup amplifier

Type Number 304-128-400

Type 6 LME 01

Description Line monitoring board for zone control unit, monitoring of up to 6 speaker
circuits (for impedance changes, short circuit and earth leakage, cable
break), measuring frequency and interval can be selected, LEDs to
indicate error states

Type Number 304-110-300

Doc. no. DAT-304-127-500 • Rev. 4 • EN • 12.07.2016 Subject to technical modifications

© INDUSTRONIC 3/5
Type 3 DSM 01

Description Bus board to add another zone control unit

Type Number 304-127-500

Type LME Bypass

Description Alternative plug-in module for the 6 LME 01 line monitoring board
(if monitoring of the speaker circuits is not required).

Type Number 304-503-600

Technical Data
Electrical Data  Operating voltage range 42 VDC to 72 VDC

 Current consumption 200 mA to 1200 mA, depending on


the expansion stage

 Outputs Max. 72 VDC, 100 mA

 Potential-free input 10 VDC to 72 VDC

 Switchable amplifier power 300 W

 Relay contact 120 VAC / 3.5 A

Environmental Requirements and  Ambient temperature during -5 °C to +50 °C


Standards operation (+23 °F to +122 °F)

 Relative humidity Max. 95 %


(non-condensing)

Doc. no. DAT-304-127-500 • Rev. 4 • EN • 12.07.2016 Subject to technical modifications

© INDUSTRONIC 4/5
Block Diagram

La / Lb from the 12 DDL 0x digital line card


V1 to V9 Amplifier circuits
SC1 to SC18 Speaker circuits
Z Measurement of line impedance
+V / -V Operating voltage
OUT1 / OUT2 Control line outputs
IN+ / IN- Potential-free input
M1 to M3 Indication "Measurement active”

INDUSTRONIC®
Industrie-Electronic GmbH & Co. KG
Carl-Jacob-Kolb-Weg 1
97877 Wertheim / Germany

Tel.: +49 9342 871-0


Fax: +49 9342 871-565

info@industronic.de
www.industronic.com
Doc. no. DAT-304-127-500 • Rev. 4 • EN • 12.07.2016 Subject to technical modifications

© INDUSTRONIC 5/5