Annex
Annex
Annex
Annex
1. Sectional moduli of Sections sections are being used differ from those standards the exact
dimension and moduli of these sections are to be submitted.
The section moduli of frames, beams stiffeners and other
parts made of sections as given in the Rules are valid for
sections in conjunction with plating to which they are 2. Scantlings of brackets
welded. For the determination of the required sections the
following Tables can be applied for moduli from 5 to The scantlings of brackets given on pages A-2 through A-11
2350 cm3 without having to determine especially the apply for the case that both brackets and attached sections
effective width of plating. are made of ordinary hull structural steel.
The sections moduli of the sections are to be applied only
in connection with these Rules. The section moduli given 3. Sectional properties of built girders
are based on the assumption of an effective width of plating
The moment of inertia and section moduli of transverses,
of 40 @ tw (tw = web thickness of the section).
girders etc., determine according to the Rules, may be
The given scantlings of the sections are valid only for angles derived from the graphs on pages A-12 and A-13 of this
according to DIN 1028 and 1029, bulb angles according Annex.
to DIN 1020, bulb plates according to DIN 1019. Where
A-2 Annex
5 S 50 x 5
6 S 50 x 6
7 S 50 x 7
9
S 65 x 6
10
S 60 x 8 S 100 x 6,5
S 60 x 4
11 S 65 x 7
S 75 x 6
12
S 60 x 5
S 65 x 8
13
S 60 x 6
14
S 75 x 7
S 80 x 7
15
16
S 60 x 40 x 5 S 75 x 8
17
18
S 75 x 9
19
S 60 x 40 x 6
20 S 80 x 5
21 S 65 x 50 x 5 S 75 x 10
22
S 60 x 40 x 7
S 80 x 6 S 90 x 8
23
24
S 100 x 6,5
Annex A-3
25 S 110 x 6,5
S 75 x 50 x 5 S 80 x 7
S 90 x 9
26
27 S 75 x 55 x 5
S 100 x 8
28
S 80 x 40 x 6
29 S 65 x 50 x 7
S 90 x 10
30
31 S 100 x 9
32 S 120 X 6,5
S 110 x 8
S 90 x 11
33
34
S 100 x 6
S 75 x 50 x 7
35
S 100 x 10
36
S 90 x 12
S 65 x 50 x 9
37 S 75 x 55 x 7
S 80 x 40 x 8 S 110 x 9
38
S 100 x 7 S 120 x 8
39
S 80 x 65 x 6 S 100 x 11
40
41
S 110 x 10
42
S 100 x 8 S 130 X 6.5
43
S 90 x 60 x 6
S 120 x 9
44
S 75 x 50 x 9
A-4 Annex
46
47 S 110 x 11
S 75 x 55 x 9
48
S 120 x 6
49
S 120 x 10 S 140 x 6,5
50
51
S 110 x 12
52 S 80 x 65 x 8
53
54 S 120 x 7
S 120 x 11
55
56
57 S 90 x 60 x 8
S 130 x 10 S 150 x 6,5
S 150 x 8
58
59 S 90 x 75 x 7
S 100 x 50 x 8
60 S 120 x 8
S 120 x 12
61
S 100 x 65 x 7
62
63
Annex A-5
[cm3]
non-flanged flanged
64 S 80 x 65 x 10
S 140 x 10 S 160 x 6,5 S 160 x 6,5
66
S 100 x 75 x 7 S 140 x 6
68
S 120 x 13
70
S 140 x 11
72
S 100 x 50 x 10
74 S 170 x 6,5 S 170 x 6,5
S 140 x 7 S 150 x 10
76
S 120 x 14
78
S 100 x 65 x 9
S 140 x 12
80
82
S 140 x 8
S 160 x 10
84
8
86 S 180 x 7,0 S 180 x 6,5
S 100 x 75 x 9
88 S 140 x 13
90
S 140 x 9
92 S 150 x 12 Flange
50 mm
94
S 100 x 65 x 11
96
S 140 x 14
98
[cm3]
non-flange flange
S 160 x 7
105 S 100 x 75 x 11 S 160 x 12
S 120 x 80 x 8 S 180 x 10
110 S 130 x 75 x 8
S 160 x 8
S 160 x 13
115 S 200 x 7,5 S 200 x 6,5
S 140 x 16
120
S 160 x 9
S 120 x 80 x 10 S 180 x 12
130
S 210 x 7,5 S 210 x 6,5
135
S 130 x 75 x 10 S 160 x 15
145 S 180 x 8
S 160 x 16
S 130 x 65 x 12 S 220 x 8,0 S 220 x 6,5
150 S 150 x 75 x 9
S 120 x 80 x 12 S 180 x 14
155 S 130 x 90 x 10
S 180 x 9
160 S 160 x 17
S 130 x 75 x 12
165 S 180 x 15
S 230 x 8,0 S 230 x 7,0
170 S 160 x 18
S 180 x 10
175
S 120 x 80 x 14
S 150 x 75 x 11 S 180 x 16
180
S 130 x 90 x 12
195
200 S 200 x 15
S 150 x 100 x 10 S 245 x 8,5 S 245 x 7,0 9
Annex A-7
[cm3]
non-flanged flanged
S 200 x 9 S 180 x 18 8
210 S 250 x 8,5 S 250 x 7,0
220 S 200 x 16
S 200 x 10 S 220 x 14
S 150 x 90 x 12
230 S 160 x 80 x 12
S 200 x 17 S 260 x 9,0 S 260 x 7,5
S 220 x 17
280 S 150 x 100 x 14 S 220 x 10 S 200 x 20
S 240 x 15 S 280 x 9,5 S 280 x 8,0
S 180 x 90 x 12
290
S 180 x 90 x 14 S 240 x 17
330 S 260 x 15
S 220 x 20
340
S 240 x 10
S 240 x 18 S 300 x 10,0 S 300 x 8,0
350
S 260 x 16
S 200 x 100 x 12
360 Flange
55 mm
S 240 x 11 S 240 x 19
370
400 S 260 x 18
S 315 x 10,5 S 315 x 8,5 9
A-8 Annex
[cm3]
non-flanged flanged
S 280 x 16 8
410
S 200 x 100 x 14
S 320 x 10,5 S 320 x 8,5
420
S 260 x 10
430 S 260 x 19
S 280 x 17
440
S 260 x 11
450
9
S 250 x 90 x 12 S 260 x 20 S 330 x 11,0 S 330 x 9,0 8
460
S 280 x 18
470 S 200 x 100 x 16 S 260 x 12
480
490 S 300 x 17
S 280 x 19 S 340 x 11,0 S 340 x 9,0
S 260 x 13
500
510 Flange
60 mm
520 S 280 x 20
S 300 x 18
530 S 250 x 90 x 14 S 280 x 11
550 S 280 x 21
S 300 x 19
560
S 280 x 12
570
580 S 280 x 22
S 360 x 11,5 S 360 x 9,5
590 S 300 x 20
S 320 x 18
S 280 x 13
600
S 250 x 90 x 16 9
Annex A-9
660
S 300 x 22
S 300 x 12 S 320 x 20 S 380 x 12,0 S 380 x 10,0
680
900 S 340 x 12
S 320 x 15 9
8
920 S 320 x 26 S 420 x 13,5 S 420 x 10,5
S 340 x 24
S 300 x 22
940 S 320 x 16
S 340 x 13
960 Flange
S 340 x 25 75 mm
980
S 430 x 13,5 S 430 x 11,0
1000 S 340 x 14
9
A - 10 Annex
1080 S 340 x 16
1100
S 340 x 28
1120 S 450 x 14,0 S 450 x 11,5
S 360 x 26
S 380 x 24
1140 Flange
80 mm
1160
S 370 x 13
1180
1300
1320 S 370 x 16
S 360 x 30
1340
S 380 x 28
1360 S 480 x 15,0 S 480 x 12,0
S 400 x 26
S 370 x 17 S 420 x 28
1380 Flange
90 mm
1400
Annex A - 11
2000
S 430 x 17
S 550 x 17,5 S 550 x 14,0
2050
S 430 x 18
2100 S 440 x 32
S 460 x 30
2150 S 560 x 17,5 S 560 x 14,0
S 430 x 19
2200
2250 S 430 x 20
S 570 x 18,0 S 570 x 14,5
S 460 x 32
2300
2350
S 430 x 21
S 580 x 18,0 S 580 x 14,5
2400
On application, Biro Klasifikasi Indonesia (BKI) calculate They shall be permanently attached on both sides of the
freeboards in accordance with the Regulations of the Load ship.
Line Convention 1966 and with any existing relevant special
With ships having a restricted service range, depending
national regulations, and subsequently issue the necessary
on the respective range, the seasonal markings, such as for
Load Line Certificates wherever authorized to do so by the
Winter North Atlantic trade, are omitted.
competent Authorities of the individual States.
Applications for issuance of Load Line Certificates or for Ships of over 100 m length do not get a WNA marking.
surveys of freeboard admeasurements are to be made to For these ships WNA is equal to W and the LWNA marking
either BKI Head Office, Jakarta, or the Surveyors. is affixed at the same level as the W-mark.
Freeboards are then calculated and based on survey Reports
For ships the keels of which were laid prior to 21st July,
and admeasurements Certificates are to be issued.
1968, the conditions for assignment of the freeboard subject
The load lines assigned by BKI are marked amidships in to the Load Line Convention 1930 continue to be valid as
accordance with the Freeboard Marking as per sketches a part of the LLC 66. Where the advantages of the LLC 66
on page A-l5 which is drawn for the starboard side. Where are intended to be utilized, the respective ships are to comply
no other marking is stipulated by national regulations of with all requirements of that Convention as for a new ship.
the respective foreign Authorities, there will be added the
letters KI. The ring, lines and letters are to be painted white
or yellow on a dark ground, or else, black on a light ground.
Annex A - 15
25 mm
300 mm
TF
50 mm
115mm
75 mm
m
35 mm
These measurement
T
230 mm
Upper edge S
of horizontal line passing
through the centre of ring W
25 mm
25 mm
WNA
300 mm 25 mm 230 mm
450 mm
25 mm
Freeboard Marking for Seagoing Ship Carrying Timber Deck Cargoes *)
25 mm
300 mm
deck line
LTF
50 mm
TF
115mm
LF
LT 75 mm
to be taken from centre
of ring to top each line
35 mm
These measurement
230 mm
LS F
These measurement
T
230 mm
LW S
W
25 mm
LWNA
25 mm
WNA
230 mm 25 mm 300 mm 25 mm 230 mm
25 mm
450 mm
25 mm
Upper edge
of horizontal line passing
through the centre of ring
*)
Drawn for the starboard side
A - 16 Annex
III. SI UNIT