Fischer Tunnel Construction
Fischer Tunnel Construction
Fischer Tunnel Construction
Global presence
With more than 40 national subsidiaries and are clear. There‘ll always be a competent technical or sales
more than 100 importers, fischer has a global partner in your vicinity and a high level of product availability
network with a strong presence. The is also guaranteed.
advantages for you as a project customer
Customer advice
Our technical support service provides and the development of special solutions. Around
cost-effective, legally compliant advice for all the world, more than 130 engineers support you with
questions relating to fastening systems. their concentrated fastening expertise. We‘re happy to
Services that you can access include test installations, give you advice – at our fischer Academy, at your office or at
pull-out tests, individual designs, comparative calculations, the construction site itself.
Products
We offer you a wide range of fastening solutions from the experience gleaned during
fields of chemical resins, steel and plastics. We cover a very broad more than 60 years in ancho-
application spectrum with our standard products as well as ring technology. You can
project-based solutions and customer-specific special depend on it.
developments. All of these are based on our know-how and
2
Services for tunnel construction.
Production
With research and development, tool-making, Through the fischer Process System (fPS), we
special machine construction and produc- continuously optimise our processes and adapt
tion facilities for chemistry, steel and flexibly to customer requirements. In
plastics, the entire production process of this way, we ensure that you can
our products takes place in-house. Our rely on innovative products with
quality management system is certified in a constantly high level of quality.
accordance with DIN EN ISO 9001.
Design software
Our new modular design application documents and extensive choice of all conventional
software suite is called load and measurement units make the software suitable for
„Fixperience“. It offers safe international use. A free „live update“ is available at all times at:
and reliable design along with www.fischer.de/fixperience
top processing comfort. The
relevant design standards
(ETAG 001 and EC2), national
Certifications
We don‘t compromise on the safety of our products. We take to their work. Many of our products are characterised by thorough,
part in the leading international, standard-setting councils in the up-to-date, international approvals, technical certifications and
fastening technology sector, thus contributing our knowledge expert reports. For you, this means safety that you can rely on.
The environment
We actively consider the aspect of sustainable (EPD) from the Bauen und Umwelt e.v.
construction. Our environmental management (IBU) institute, which constitutes the data basis for an
system is certified in accordance with DIN EN ecological building evaluation. And our greenline product range
ISO 14001. A growing number of our products is already based on more than 50% sustainable raw materials –
have an Environmental Product Declaration certified in accordance with DIN CERTCO/TÜV Rheinland.
3
Solutions for rail and road tunnels.
Ventilation
Suspended ceiling
Traffic signs
Traffic lights
Fire boards,
Safety and crash
substrate protection
barriers
4
Content
Page Page
■ Fire protection 6 ■ Ventilation / smoke extraction 12
■ Electrical installations / illumination 8 ■ Structural design and steel works 13
■ Power supply – Catenary system and 3rd rail 9 ■ Other equipment and installations 14
■ Rail fixing - track 10 ■ Supply and service tunnels 15
■ Safety 11
Ventilation
Catenary system
Illumination
Signal system
Railing
Rail fixing
5
Fire protection.
Sprayed Coating
FNA II
Application:
Fixing of bent or flat reinforcement mesh for
Standard nail head with or without washer - sprayed fire protection coating.
tfix 5 to max 20 mm Round or rectangular washers according to
system requirements for preformed mesh with
Washer – Standard size 7,5 x 30 x FNA II or FBS.
1,5 mm in steel grade according to
FNA II with nail head in combination with the
the FNA II
patented spacer for flat mesh (wire 1.5 mm).
Spacing mesh to concrete surface 13 mm or
Spacer – standard sizes for mesh 18 mm.
distance to the concrete of 13 mm or
18 mm as standard
FBS
Special Products
6
Fire protection.
Board Systems
FNA II Application:
Fixing of board materials with or without backing
strips with total fixture thickness of up to 120 mm.
FNAII M6
Standard embedment depth of only 30mm (drill
depth of 35 mm / red. 30 mm).
Standard nail head with or without washer – FNA II RB with nail head, detachable nail head,
usable length up to 125 mm thread nut, or as an alternative the FBS 6.
FNA II RB Concrete screw FBS with up to 45 mm fixture
thickness if the risk of unscrewing by vibration /
alterneting deflection of the board is not given.
detachable nail head with washer – usable Other dimensions for all products on request.
length up to 125 mm
Accessories
7
Electrical installations / illumination.
Electrification
FAZ II
Application:
Ductwork for cables or heavy cable trays, using
drop-in, through bolt anchors all load requirements
FBN II can be covered.
Alternatively with bonded anchors, higher loads
and smaller edge distances can be achieved.
FNA II
EA II
RGM
with RM or FIS V
Lighting
FBS Application:
Emergency lighting or heavy suspended flood
lights, whatever your requirements are, with
FH II fastest curing bonded anchors, undercut anchors
or mechanical anchors fischer can offer the most
efficient solution for your application.
FZA / FZEA
RGM / RGM I
FHB II
8
Power supply – Catenary system
and 3rd rail.
Overhead systems
FHB II with FIS HB
Application:
Overhead conductor rail and standard catenary
systems are often executed as stand-off
installations with high load and safety standards.
FIS A with FIS EM With the fischer bonded anchor range highest
loads can be transferred, even with limited drill
depth due to layers of watertight membranes in
the wall structure.
RGM with RM or RSB The undercut system of the FZA offers highest
safety even in cracked concrete.
FZA
RGM / RGM I
FHB II
9
Rail fixing - track.
Metro rail
fischer rail anchor RA M22x220
Application:
axle load, electric isolated
Light rails for tramways fixed on a slab track are
a typical application of the fischer rail anchor RA
M 22x270. The three component mortar, based
fischer rail anchor RA M22x270 on epoxy resin is guaranteed not to shrink, and
to axle load, electric isolated supports under the high loaded rail base plates.
10
Safety.
FAZ II
SXR-FUS
FBS
11
Ventilation / smoke extraction.
FAZ II
Temporary supply
FBS Application:
Temporary air ducts, cables and pipes for
ventilation, illumination, water supply and
evacuation can be fixed with zinc-plated fixings
FNA II gvz, A4, FNA II RB according to their load requirements.
Long tunnels with high coverage may also
necessitate a special cooling system.
EA II
S/SX with GS
12
Structural design and steel works.
Structural applications
FIS EM Application:
If high loads according to anchor or rebar theory
have to be resisted, with FIS EM, FIS V or the new
FIS V FIS SB, requirements according to ETA or ICC can
be fulfilled.
Heavy suspended ceilings, wall protections, curbs
or separation walls – with bonded or undercut
FIS SB - Superbond systems in different steel grades and with fire
approvals, advanced solutions are available.
FZA
FHB II
13
Other equipment and installations.
EA II
SXR-FUS
Wall cladding
FAZ II Application:
Whatever material is used for cladding the walls
in stations, we have the adequate fixing solution
for the cladding itself and substructure if required.
RGM With the fischer ACT system fischer offers a
service and maintenance friendly solution for
claddings with natural and artificial stone, HPL,
ceramic and glass.
FBN II
SXR-FUS
14
Supply and service tunnels.
FZA
RGM + Patrone
15
Product specifications and accessories.
dy-
material method of operation type of installation relevant approvals for use in tunnels namic
Product overview
high corrosion resitant
stainless steel e.g. A4
connection thread
pre - positioned
internal thread
push-through
interlocking
Shock approval by
expansive
adhesive
Helpful accessories
Electric isolated
Clips fixing points
16
Basic knowledge.
Cracked concrete types of corrosions can be differentiated here. The most frequent
When anchoring in concrete, it is almost types of corrosion in fixings and anchors include:
presumed that cracks are present in the
anchoring area that influences the
bearing capacity of the fixings. It is
Surface corrosion
difficult to define all temporary and In this case, the metal corrodes relatively uniformly over the enti-
permanent load cases and to determine re surface or over a part of the surface. An example of this is the
if the concrete is cracked or non-cracked. invisible rusting due to condensation of a screw in the transition
For safety reasons, the use of fixings suitable area from anchor plate to hole. The result: The connection which
for cracked concrete is generally recommended for engineers, appears completely intact from the outside fails abruptly.
designers and specifiers. Fixings with an approval according to
ETAG 001 for cracked concrete have proved their suitability in
cracks and may be used without any restriction in the tensile and Contact corrosion
compressive zones of concrete members. Fixings suitable for If metals with different quality contact each other in a conductive
cracked concrete are also checked and approved according to medium, the less noble metal always corrodes (the anode). As a
American standards. These “evaluation reports” are prepared consequence, stainless steel is usually not endangered. What is
according to ACI 318. decisive, are the surface ratios of the two types of metal: the
greater the surface area of the higher quality metal in comparison
to the lower quality materials is, the greater the corrosion becomes.
Dynamic/fatigue behaviour
The general building authority approved by For example, if large stainless steel sheets are screwed with
the German Institute of Construction galvanised screws, the screws will be highly attacked within a
Engineering in Berlin (DIBt) and the European very short time. In contrast, using stainless steel screws for
Technical Approvals (ETA) are generally galvanised sheets is not critical.
exclusively for anchoring of static and pre-
dominantly static loads. However, in contrast to these current
approvals, in practice a number of dynamic effects occur, e.g. Stress corrosion cracking
increasing and alternating stresses in case of a lot applications In case of sustained tensile loads, also A4, grade 316 material
in a road tunnel. The main focus in this case is on, e.g. jet vans, can be attacked by stress corrosion cracking. In this process, a
overhead sign structures, etc. The applications are influenced crack develops due to mechanical stresses and chemical pro-
by heavy traffic generating compression and sucktion action on cesses (chromium depletion), which grows under sustainded
interior components. tensile loads in aggressive conditions and thus prepares a path
for progressive corrosion.
The fischer Highbond anchor FHB dyn is approved for dynamic
loads. The approval applies to anchoring of dynamic loads with For example, it occurs with A4 steel in an atmosphere with
unlimited numbers of load cycles, for tension and for shear loads. chemical pollution like road tunnels containing carbon
In addition, the FHB dyn is manufactured in anchor size M16 of monoxides, deicing materials, etc. Generally stress corrosion
high corrosion-resistant steel, material no.1.4529. cracking is not visible with fixings and usually leads to sudden
failure of the anchoring and the construction.
Tests have shown that this material - in contrast to the usual
standard stainless steel types in the corrosion resistance class III,
e.g. A4, steel grade AISI 316- is suitable not only for use in Fire resistance
humid internal and external conditions, but also for dynamic loads. Systems like cable trays, ventilation or utility
systems are tested not only for fire resistance,
but also for functional capabilities in the case
Corrosion of fire (e.g. supply lines to sprinkler systems,
Corrosion is a chemical reaction in which metal is decomposed. fire protection boards, etc.). The fire resistance
The lower quality of the metal (“electrochemical potential“), the duration of these systems is specified for the application in
material will be even more damaged. In this process it is either tunnels according special developed tunnel fire curves.
converted into flaking rust or worn away in places. These two Actually there are different tunnel fire curves available and it
17
Basic knowledge.
18
References.
Metro Milan
Challenge Solution
The project ML5 has been developed fischer has provided technical products
according to the requirements of the Milan for more than 35,000 rails attachment
Metro. fischer was the only player capable plates, in particular Rail Anchor M22x270 -
of providing all required subsystems for the 75,000 pcs and 4,800 cartridges of FIS EM
rail fastening solution. fischer has provided 1500. All works have been executed on
engineering and technical support both on time and all testing was successful.
and off site throughout the full project period.
Hatfield tunnel UK
Challenge Solution
Challenge on this project was to comply fischer was specified and used on all
with stringent Highway Agency Design applications in this tunnel, fixing passive
Manual BD 78/99 and Interim Advice fire protection, M&E services, polyvision
Note 104/07. For the subcontractor, wall cladding and tunnel ventilation. FNA
it was important that fischer offered a II 6x30/30 A4 nail anchor was specified
comprehensive package: advance and fully because it was tested as part of the passive
tested products backed up with a proactive fire protection system and RWS fire tests
technical support offering not only design were already available for FNA anchor in
consultancy but also site support with conjunction with the specified passive fire
installation trainings and suitability site protection boards. For fixing jet fans FHB
testing in accordance to BS5080 and dyn M16x125/50C anchors were used
vigorous IAN 104/07. because of its dynamic approval.
Gotthard Base tunnel
Challenge Solution
Long-term safety and minimized mainte- FIS A M16 to M30 made of high corrosion
nance requirements for decades, this was resistant steel (1.4529) together with FIS
the main requirement of the project owner EM was used for about 40,000 fixing points
for the installation of the catenary system. of the catenary system. A systematic quality
At the same time the system supplier asked control with hundreds of successful pull-out
for an easy to install, economic solution tests was established. The heavy installation
with adjustable stand-off installation, high of the complete catenary system was over-
loads and limited drill-hole depth. head. Therefore fischer developed and deli-
vered installation clips in nylon and steel, to
prevent the heavy anchor bolt slipping out
by proper weight, during the curing time of
the chemical mortar.
Mont Blanc tunnel
Challenge Solution
After the disastrous fire in 1999 the single In spite of the defined standards and based
tube tunnel with only one lane in each on latest state of the art know how, fischer
direction was completely refurbished and decided to propose an alternative technical
modernised. In the 11.6 km long tunnel also solution with anchors for dynamic loads
the tunnel ventilation systems had to be and high corrosion resistance, the FHB Dyn
updated. Of course this applies also for the 16x125/110 C. With the French certifying
fixings of the 76 tunnel fans. New technical body CETU the needs in case of fire have
specifications with dynamic loads, high been approved.
resistance to corrosion and latest standards
for fire resistance had to be fulfilled.
19
fischer FIXPERIENCE.
The new design and information software suite.
The new modular design program includes engineering software and
application modules.
The software is based on international design standards (ETAG 001 and
EC2, such as EC1, EC3 and EC5), including the national application docu-
ments. All common force and measurement units are available.
Incorrect input will be recognized and the software gives tips to get a
correct result. This ensures a safe and reliable design every time.
The graphical display can easily be rotated through 360°, panned, tilted
or zoomed as required.
The 3 D display gives a detailed and realistic image.
The “live update” feature helps to keep the program up to date ensuring
you are always working with the latest version.
Free download and updates at www.fischer.de/fixperience-en
535158(1) · 8/2015 · Printed in Germany · We reserve the right to make technical modifications.
fischer ACADEMY.
Design and construction software for demanding applications.
See the extensive main catalogue or visit our website at www.fischer.de for information
about the complete fischer range