Hawke Cable Glands
Hawke Cable Glands
Hawke Cable Glands
PAGE DESCRIPTION
78 Introduction
80
81
contents
Hazardous Area Cable Gland Features
Connection Solutions
www.ehawke.com HPG01
Hazardous Area Contents
Cable Glands 75
PAGE DESCRIPTION
101 Stopping Plug Type: M475 & M477, Blanking Flange Type 470
Connection Solutions
www.ehawke.com HPG01
Cable Glands Selection
Chart 77
CSB 153 /
SB 150 / 151 / 153 / 153
656 & 121 123 RAC 114 153/X 701 711 710 753 755 Gland Type/Function
474 656N RAC RAC RAC UNIV
L
Industrial
Industrial ( UL Wet Locations )
Dual certified EExe / EExd
Certified IECEx
Certified ExnR
Group II certified
Group I certified
Certified Class 1, Div 1
Certified Class 1, Div 2
Certified Class 1, Zone 1
Certified Class 1, Zone 2
Certified UL / cUL
Certified CSA
Certified Cepel
Certified GOST-R
Certified GOST -K
Certified DNV Marine approval
Certified ABS Marine approval
For use with non-armoured elastomer
& plastic insulated cables
May be used on unarmoured cables
incorporating inner & outer sheaths
For use with single wire armoured 'W',
wire braided 'X' and steel tape armoured
'Z' elastomer and plastic insulated cables
For use with single wire armoured 'W',
wire braided 'X' and steel tape armoured
'Z' cables with a lead inner sheath
For use with pliable wire armour
For use with braided cables only
For use with single wire armour only
For cables exhibiting
'cold flow' characteristics
For cables that are not substantially
compact and circular, have extruded
bedding and any fillers are hygroscopic
For use with continuous corrugated
aluminium, interlocked aluminium and
iterlocked steel metal clad and teck cables
Provides a diaphragm seal on the
cables inner sheath
Provides a compound barrier seal between
the individual insulated cores within
the cable
Provides an elastomeric seal between the
individual insulated cores within the cable
For use with enclosures containing
an ignition source in gas group II C areas
For use with enclosures exceeding 2 litres
in volume, containing an ignition
source and installed in a Zone 1 area
Comes with a deluge boot as standard
Has a 'compression' type seal
Can be used with conduit systems
Connection Solutions
HPG01
www.ehawke.com
Introduction Cable Glands
78
The cost of a cable gland is insignificant when compared to that of other equipment. However, the cost of failure is high.
Though some cable glands may be “fit for purpose” what would be the potential cost of failure?
The cable gland can become the weak link in the chain whereas it should preserve the integrity of the installation.
Once fitted, all Hawke Cable Glands can be easily disassembled to allow visual inspection of the inner seal on the cable sheath
(501/453/UNIVERSAL) and full inspection, and if necessary repair of the cured compound in the barrier glands. No other barrier
gland on the market will allow this.
With low numbers of gland components making installation extremely simple, Hawke Cable Glands are right first time, every time.
For more information on specific features and benefits see pages 80, 94, 104 & 112.
Connection Solutions
www.ehawke.com HPG01
Cable Glands - 79
Group II
Features Hazardous Area
80 Cable Glands
3
5
5 501/453 UNIVERSAL
2
Connection Solutions
www.ehawke.com HPG01
Cable Glands 501/421
Hazardous Area 81
Flameproof Exd, Increased Safety Exe & Dust Extb
Dual Certified ATEX / IECEx (Fully Compressed Length)
15.0mm G' Approx
Metric
Entry
Application
Entry Thread
The 501/421 cable gland provides a seal on the outer cable sheath and
Ø 'B'
is intended for use on non-armoured elastomer and plastic insulated
cables. The cable gland is certified Exd, Exe and Extb, suitable for
installation in Zone 1 (21) and Zone 2 (22) hazardous areas.
Connection Solutions
HPG01
www.ehawke.com
UPD 150113
501/423 Cable Glands
82
Hazardous Area
Flameproof Exd & Increased Safety Exe
Dual Certified ATEX / IECEx
Metric
Entry
Application
Entry Thread
Ø 'B'
elastomer and plastic insulated cables. The first is a flameproof seal on the
inner or outer cable sheath, with an additional IP seal on the outer sheath.
The cable gland is dual certified Exd and Exe and is suitable for installation in
Zone 1 (21) and Zone 2 (22) hazardous areas.
Cable Gland Type Size Thread (Optional) Cable Gland Type Size Thread (Optional)
501/423 C M32 S 501/423 C 1 1⁄4"NPT S
Connection Solutions
www.ehawke.com HPG01
UPD 090610
Cable Glands 501/453 RAC
Hazardous Area 83
Flameproof Exd & Increased Safety Exe
Dual Certified ATEX / IECEx
Entry Thread
• For use with single wire armour‘W’, wire braid‘X’, steel tape armour‘Z’,
Ø 'A'
Ø 'B'
elastomer and plastic insulated cables.
• See technical section for installation rules and regulations.
¹ Smaller value is applicable when selecting reduced NPT entry option. ² Sizes Os and O are available with an M16 thread size. For O size with M16 thread, the
maximum cable inner sheath diameter is 10.9mm.
Connection Solutions
HPG01
www.ehawke.com
UPD 170610
501/453/UNIVERSAL Cable Glands
84
Hazardous Area
Flameproof Exd & Increased Safety Exe & Restricted
Breathing ExnR Dual Certified ATEX / IECEx
• For use with single wire armour ‘W’, wire braid ‘X’, steel tape armour ‘Z’,
Ø 'B'
Ø 'A'
Ordering Information
Format for ordering is as follows: Alternative Clamping Ring (AR), add suffix AR to ordering information.
Cable Gland Type Size Thread (Optional) Cable Gland Type Size Thread (Optional)
501/453/UNIV C M32 AR 501/453/UNIV C 1 1⁄4"NPT AR
Connection Solutions
www.ehawke.com HPG01
UPD 170610
Cable Glands 501/453/RAC/L
Hazardous Area (for Lead Sheath Cables) 85
Flameproof Exd & Increased Safety Exe
Dual Certified ATEX / IECEx
Application Entry
Entry Thread
• For use with single wire armour ‘W’, wire braid ‘X’, steel tape armour ‘Z’,
Ø 'B'
Ø 'A'
elastomer and plastic insulated cables with a lead inner sheath.
• See technical section for installation rules and regulations.
Ø 'B'
- Cables that are not effectively filled, compact and/or circular, have tape
bedding or have hygroscopic fillers.
- Cables that exhibit ‘Cold Flow’ characteristics.
- Enclosures for gas group IIC, under 2 litres in volume and containing
an ignition source.
- Enclosures for gas groups IIA or IIB, which are greater than 2 litres in volume
and contain an ignition source.
• See technical section for installation rules and regulations
CABLE GLAND SELECTION TABLE
Entry Thread Size Cable Acceptance Details Hexagon Dimensions
Size “NPT * Outer Sheath 'B' Armour / Braid 'C' ‘G’ Across
Ref. Metric Standard or Across Flats
Orientation Orientation Corners
Option” Min. Max.
1 2
A M20 ¾" or ½" 12.5 20.5 0.8 / 1.25 0.0 / 0.8 53.0 30.0 32.5
B M25 1" or ¾" 16.9 26.0 1.25 / 1.6 0.0 / 0.7 69.5 36.0 39.5
C M32 1¼" or 1" 22.0 33.0 1.6 / 2.0 0.0 / 0.7 64.0 46.0 50.5
All dimensions in millimetres (except * where dimensions are in inches). Metric entry threads are 1.5mm pitch as standard, 15mm length of thread.
Ordering Information
Format for ordering is as follows: To obtain punch tool required, refer to tables.
Cable Gland Type Size Thread Punch Tool Required Cable Gland Type Size Thread Punch Tool Required
PSG 553/RAC C M32 Punch Tool No. 1 PSG 553/RAC C 1 1⁄4"NPT Punch Tool No. 1
Connection Solutions
www.ehawke.com HPG01
UPD 090610
Cable Glands ICG 623
Hazardous Area 87
Flameproof Exd & Increased Safety Exe
Dual Certified ATEX / IECEx
• For use with non-armoured elastomer and plastic insulated cables. Entry
Entry Thread
Ø 'B'
- Cables that are not effectively filled, compact and/or circular, have
Ø 'D'
Ø 'E'
tape bedding or have hygroscopic fillers.
- Cables that exhibit ‘Cold Flow’ characteristics.
- Enclosures containing an ignition source in gas group IIC areas or
containing an ignition source in a Zone 1 area and exceeding 2 litres
in volume.
• See technical section for installation rules and regulations.
Ordering Information
Format for ordering is as follows: Alternative Seal (S), add suffix S to ordering information.
Cable Gland Type Size Thread (Optional) Cable Gland Type Size Thread (Optional)
ICG 623 C M32 S ICG 623 C 1 1/4" NPT S
Two part sealing compound and assembly instructions are supplied with the cable gland.
Connection Solutions
HPG01
www.ehawke.com
UPD 090610
ICG 653/UNIVERSAL Cable Glands
88
Hazardous Area
Flameproof Exd & Increased Safety Exe & Restricted
Dual Certified ATEX / IECEx
Application
15.0mm 'G' Approx (Fully Compressed Length)
• Outdoor or indoor use.
Metric
Entry
Inspectable
Compound Deluge Boot Armour/Braid 'C' • For use with single wire armour ‘W’, wire braid ‘X’, steel tape armour ‘Z’,
elastomer and plastic insulated cables.
• For particular use with:-
Entry Thread
Ø 'B'
have tape bedding or have hygroscopic fillers.
- Cables that exhibit ‘Cold Flow’ characteristics.
- Enclosures containing an ignition source in gas group IIC
areas or containing an ignition source in a Zone 1 area.
• See technical section for installation rules and regulations.
CABLE GLAND SELECTION TABLE
Entry Thread Size Cable Acceptance Details Hexagon
Dimensions
Size Metric NPT * Inner Sheath / Cores 'G'
Ref. Standard Max. Over Max Inner Max. No. of Outer Sheath ‘B’ Armour / Braid ‘C’ Across Across
or Option Cores ‘D’ Sheath ‘E’ Cores Flats Corners
Min Max Orientation 1 Orientation 2
Os M20 ½" 8.9 10.0 6 5.5 12.0 0.8 / 1.25 0.0 / 0.8 67.0 24.0 26.5
O M20 ½" 8.9 10.0 6 9.5 16.0 0.8 / 1.25 0.0 / 0.8 67.0 24.0 26.5
A M20 ¾" or ½" 11.0 12.5 10 12.5 20.5 0.8 / 1.25 0.0 / 0.8 67.0 30.0 32.5
B M25 1" or ¾" 16.2 18.4 21 16.9 26.0 1.25 / 1.6 0.0 / 0.7 73.6 36.0 39.5
C M32 1¼" or 1" 21.9 24.7 42 22.0 33.0 1.6 / 2.0 0.0 / 0.7 78.0 46.0 50.5
C2 M40 1½" or 1¼" 26.3 29.7 60 28.0 41.0 1.6 / 2.0 0.0 / 0.7 82.4 55.0 60.6
D M50 2" or 1½" 37.1 41.7 80 36.0 52.6 1.8 / 2.5 0.0 / 1.0 88.7 65.0 70.8
E M63 2½" or 2" 47.8 53.5 100 46.0 65.3 1.8 / 2.5 0.0 / 1.0 92.7 80.0 88.0
F M75 3" or 2½" 59.0 66.2 / 65.3¹ 120 57.0 78.0 1.8 / /2.5 0.0 / 1.0 99.4 95.0 104.0
All dimensions in millimetres (except * where dimensions are in inches). Metric entry threads are 1.5mm pitch as standard, 15mm length of thread.
¹ Smaller value is applicable when selecting reduced NPT entry option. Note: Larger sizes are available.
Technical Data Features
• Flameproof Exd and Increased Safety Exe II 2 GD ExtD A21. • Provides a barrier seal to the individual insulated cores within the cable
• Certificate No’s: Baseefa06ATEX0058X and IECEx BAS 06.0015X. and prevents entry of the products of an explosion into the cable.
• Suitable for use in Zone 1, Zone 2, Zone 21, Zone 22 and in • Assembly of the cable gland compresses and distributes the compound
Gas Groups IIA, IIB and IIC. evenly to create a barrier seal at the point of entry into the enclosure.
• Construction and Test Standards: IEC/EN 60079-0, IEC/EN 60079-1, • The compound chamber may be separated from the cured compound
IEC/EN 60079-7, IEC/EN 61241-0 and IEC/EN 61241-1. to ensure that the chamber has been effectively filled. If required,
• Ingress Protection: IP66, IP67 and IP 68 (30 metres for 7 days) to external voids can be repaired.
IEC/EN 60529 and NEMA 4X. • Provides armour clamping, using one clamping arrangement for
• Deluge Protection to DTS01. all armour / braid types.
• Operating Temperature Range: -60°C to +80°C. • Provides an outer deluge seal to prevent moisture ingress to the
• Assembly Instruction Sheet: AI 301. cable armour / braid.
• Alternative certification options available: • Provides a cable retention and low smoke and fume, zero halogen seal
onto the cables outer sheath.
Exe II BR-Exd IIC / Exe II • Manufactured in Brass (standard), Nickel Plated Brass,
Exd IIC / Exe II GOST R-Exe IIU 316 Stainless Steel or Aluminium.
GOST K- Approved for use in Kazakhstan
• Brass NPT entries are nickel plated as standard.
Alternative Reversible Armour Clamping Rings (RAC)
DNV Marine Approval ABS Marine Approval
SELECTION TABLE
Steel Wire Armour / Braid / Tape
Size Ref.
Orientation 1 Orientation 2
B 0.9 - 1.25 0.5 - 0.9
C 1.2 - 1.6 0.6 - 1.2
C2 1.2 - 1.6 0.6 - 1.2
D 1.45 - 1.8 1.0 - 1.45
E 1.45 - 1.8 1.0 - 1.45
F 1.45 - 1.8 1.0 - 1.45
Ordering Information
Format for ordering is as follows: Alternative Clamping Ring (AR), add suffix AR to ordering information.
Cable Gland Type Size Thread (OPTIONAL) Cable Gland Type Size Thread (OPTIONAL)
ICG 653/UNIV C M32 AR ICG 653/UNIV C 1 1⁄4"NPT AR
Two part sealing compound and assembly instructions are supplied with the cable gland.
Connection Solutions
www.ehawke.com HPG01
UPD 090610
Cable Glands ICG 653/UNIVERSAL/L
Hazardous Area (for Lead Sheath Cables) 89
Flameproof Exd & Increased Safety Exe
Dual Certified ATEX / IECEx
Application
• Outdoor or indoor use. 15.0mm 'G' Approx (Fully Compressed Length)
• For use with single wire armour‘W’, wire braid‘X’, steel tape armour‘Z’, Metric
Entry
Inspectable
Compound Deluge Boot
Lead Sheath Bond
Armour/Braid 'C'
elastomer and plastic insulated cables with a lead inner sheath.
• For particular use with:-
Entry Thread
- Cables that are not effectively filled, compact and/or circular, have
Ø 'D'
Ø 'E'
Ø 'B'
tape bedding or have hygroscopic fillers.
- Cables that exhibit ‘Cold Flow’ characteristics.
- Enclosures containing an ignition source in gas group IIC areas or
containing an ignition source in a Zone 1 area.
• See technical section for installation rules and regulations.
CABLE GLAND SELECTION TABLE
Cable Acceptance Details Hexagon
Entry Thread Size Dimensions
Inner Sheath / Cores
Size Metric NPT * ' D ' Max. Max Inner Max. No. of Outer Sheath 'B' Armour / Braid 'C' 'G' Across Across
Ref. Standard or Over Cores Sheath ‘E’ Cores Flats Corners
Option
Min. Max. Min. Max. Orientation 1 Orientation 2
Os M20 ½" 8.5 4.0 10.0 6 5.5 12.0 0.8 / 1.25 0.0 / 0.8 67.0 24.0 26.5
O M20 ½" 8.5 4.0 10.0 6 9.5 16.0 0.8 / 1.25 0.0 / 0.8 67.0 24.0 26.5
A M20 ¾" or ½" 10.8 7.4 12.5 10 12.5 20.5 0.8 / 1.25 0.0 / 0.8 67.0 30.0 32.5
B M25 1" or ¾" 16.2 11.0 18.4 21 16.9 26.0 1.25 / 1.6 0.0 / 0.7 73.6 36.0 39.5
C M32 1¼" or 1" 21.9 14.0 24.7 42 22.0 33.0 1.6 / 2.0 0.0 / 0.7 78.0 46.0 50.5
C2 M40 1½" or 1¼" 26.3 21.0 29.7 60 28.0 41.0 1.6 / 2.0 0.0 / 0.7 82.4 55.0 60.6
D M50 2" or 1½" 37.1 27.0 41.7 80 36.0 52.6 1.8 / 2.5 0.0 / 1.0 88.7 65.0 70.8
E M63 2½" or 2" 47.8 39.0 53.3 100 46.0 65.3 1.8 / 2.5 0.0 / 1.0 92.7 80.0 88.0
F M75 3" or 2½" 59.0 51.0 64.0 120 57.0 78.0 1.8 / 2.5 0.0 / 1.0 99.4 95.0 104.0
All dimensions in millimetres (except * where dimensions are in inches). Metric entry threads are 1.5mm pitch as standard, 15mm length of thread.
Connection Solutions
HPG01
www.ehawke.com
UPD 090610
501/414 Cable Glands
90
Hazardous Area
Flameproof Exd & Increased Safety Exe
Dual Certified ATEX / IECEx
Female Entry
Thread
Male
Ø 'B'
¹ Smaller value is applicable when selecting reduced NPT male entry option.
² Sizes Os and O are available with an M16 thread size. For O size with M16 thread, the maximum cable inner sheath diameter is 10.9mm
# NPT female thread sizes equivalent to those shown in the table for the male thread size are available. Hexagon dimensions as shown may alter.
Ordering Information
Format for ordering is as follows: Alternative Seal (S), add suffix S to ordering information.
Cable Gland Type Size Thread (OPTIONAL) Cable Gland Type Size Thread (OPTIONAL)
501/414 C M32 S 501/414 C 1 1⁄4"NPT S
Connection Solutions
www.ehawke.com HPG01
UPD 240613
Cable Glands SB 474
Hazardous Area 91
Flameproof Exd & Increased Safety Exe
Dual Certified ATEX / IECEx
Female Entry
Entry Thread
have tape bedding or have hygroscopic fillers.
Thread
Male
- Cables that exhibit ‘Cold Flow’ characteristics.
- Enclosures for gas group IIC, under 2 litres in volume and
containing an ignition.
- Enclosures for gas groups IIA and IIB, which are greater than
2 litres in volume and contain an ignition source.
• See technical section for installation rules and regulations.
CABLE GLAND SELECTION N TABLE
Male Entry Thread Size Female Entry Thread
d Size Hexagon Dimensions
Size Ref. NPT * NPTT # 'G'
Metric Metric Across Flats Across Corners
Standard or Option Standard or Option
A M20 ¾" or ½" M20 - 56.4 30.0 32.5
B M25 1" or ¾" M25 - 48.2 36.0 39.5
C M32 1¼" or 1" M32 - 61.6 46.0 50.5
All dimensions in millimetres (except * where dimensions are in inches). Metric entry threads are 1.5mm pitch as standard, 15mm length of thread.
# NPT female thread sizes equivalent to those shown in the table for the male thread size are available. Hexagon dimensions as shown may alter.
Ordering Information
Format for ordering is as follows: To obtain punch tool required, refer to tables.
Cable Gland Type Size Thread Punch Tool Required Cable Gland Type Size Thread Punch Tool Required
SB 474 C M32 Punch Tool No.1 SB 474 C 11/4"NPT Punch Tool No.1
Connection Solutions
HPG01
www.ehawke.com
UPD 090610
CSB 656 N Cable Glands
92
Hazardous Area
Flameproof Exd & Increased Safety Exe & Restricted
Dual Certified ATEX / IECEx
Female Entry
- Cables that are not effectively filled, compact and/or circular, have tape
Entry Thread
Thread
bedding or have hygroscopic fillers.
Male
Ø'D'
Ø'E'
¹ Smaller value is applicable when selecting reduced NPT male entry option.
Hexagon dimensions as shown may alter.
Technical Data Features
• Flameproof Exd and Increased Safety Exe II 2 GD ExtD A21. • Provides a barrier seal between the individual insulated cores
• Certificate No’s: Baseefa06ATEX0058X and IECEx BAS 06.0015X. within the cable and prevents entry of the products of an explosion
• Suitable for use in Zone 1, Zone 2, Zone 21, Zone 22 and in •
into the cable or conduit.
Seals conductors at entry to enclosure via conduit or enables an
Gas Groups IIA, IIB and IIC.
• Construction and Test Standards: IEC/EN 60079-0, IEC/EN 60079-1, •
existing cable gland to be converted to a barrier type cable gland.
The device is fitted with a simple compound filled chamber which
IEC/EN 60079-7, IEC/EN 61241-0 and IEC/EN 61241-1.
• Ingress Protection: IP66, IP67 and IP 68 (30 metres for 7 days) •
permits packing around individual insulated conductors.
Assembly of the cable gland compresses and distributes the
to IEC/EN 60529 and NEMA 4X.
• Deluge Protection to DTS01. compound evenly to create a barrier seal at the point of entry into
• Operating Temperature Range: -60°C to +80°C. •
the enclosure.
• Assembly Instruction Sheet: AI 375. •
If required, external voids can be repaired.
• Alternative certification options available: •
Provides female running coupler for cable gland or conduit entry.
Manufactured in Brass (standard), Nickel Plated Brass,
Exd IIC / Exe II GOST R-Exe IIU 316 Stainless Steel or Aluminium.
GOST K- Approved for use in Kazakhstan • Brass NPT entries are nickel plated as standard.
Ordering Information
Format for ordering is as follows:
Cable Gland Type Size Male Thread Female Thread Cable Gland Type Size Male Thread Female Thread
CSB 656 N C M32 M32 CSB 656 N C 1 1⁄4"NPT M32
Two part sealing compound and assembly instructions are supplied with the cable gland.
Connection Solutions
www.ehawke.com HPG01
UPD 090610
Cable Glands - 93
Group I Mining
Features Cable Glands
94
Mining
Flameproof Exd & Increased Safety Exe
Dual Certified ATEX / IECEx
4
653 UNIVERSAL
453 UNIVERSAL
2
Connection Solutions
www.ehawke.com HPG01
Cable Glands 453/UNIVERSAL
Mining 95
Flameproof Exd & Increased Safety Exe
Dual Certified ATEX / IECEx
• For use with single wire armour ‘W’, wire braid ‘X’, steel tape armour ‘Z’,
Entry Thread
elastomer and plastic insulated cables.
• For particular use with:-
Ø 'A'
Ø 'B'
- Cables that exhibit ‘Cold Flow’ characteristics.
• See technical section for installation rules and regulations.
Ordering Information
Format for ordering is as follows: Alternative Clamping Ring (AR), add suffix AR to ordering information.
Cable Gland Type Size Thread (Optional) Cable Gland Type Size Thread (Optional)
453/UNIV C M32 AR 453/UNIV C 1 1⁄4"NPT AR
Connection Solutions
HPG01
www.ehawke.com
UPD 090610
453/RAC Cable Glands
96
Mining
Flameproof Exd & Increased Safety Exe
Dual Certified ATEX / IECEx
• For use with single wire armour ‘W’, wire braid ‘X’, steel tape armour ‘Z’,
Ø 'A'
Ø 'B'
elastomer and plastic insulated cables.
• See technical section for installation rules and regulations.
SELECTION TABLE
Steel Wire Armour / Braid / Tape
Size Ref.
Orientation 1 Orientation 2
B 0.9 - 1.25 0.5 - 0.9
C 1.2 - 1.6 0.6 - 1.2
C2 1.2 - 1.6 0.6 - 1.2
D 1.45 - 1.8 1.0 - 1.45
E 1.45 - 1.8 1.0 - 1.45
F 1.45 - 1.8 1.0 - 1.45
Ordering Information
Format for ordering is as follows: Alternative Clamping Ring (AR), add suffix AR to ordering information. Alternative Seal (S), add suffix S to
ordering information.
Cable Gland Type Size Thread (OPTIONAL) Cable Gland Type Size Male Thread (OPTIONAL)
453/RAC C M32 AR 453/RAC C 1 1⁄4"NPT AR
453/RAC C M32 S 453/RAC C 1 1⁄4"NPT S
Connection Solutions
www.ehawke.com HPG01
UPD 090610
Cable Glands 453/T
Mining 97
Flameproof Exd & Increased Safety Exe
Dual Certified ATEX / IECEx
• Mining.
Entry Thread
• For use with pliable wire armoured cables.
Ø 'A'
Ø 'B'
• See technical section for installation rules and regulations.
Cable Gland Type Size Thread (Optional) Cable Gland Type Size Thread (Optional)
453/T C M32 S 453/T C 1 1⁄4"NPT S
Connection Solutions
HPG01
www.ehawke.com
UPD 090610
623 Cable Glands
98
Mining
Flameproof Exd & Increased Safety Exe
Dual Certified ATEX / IECEx
Ø 'B'
Ø 'E'
Ordering Information
Format for ordering is as follows: Alternative Seal (S), add suffix S to ordering information.
Cable Gland Type Size Thread (OPTIONAL) Cable Gland Type Size Thread (OPTIONAL)
623 C M32 S 623 C 1 1⁄4"NPT S
Two part sealing compound and assembly instructions are supplied with the cable gland.
Connection Solutions
www.ehawke.com HPG01
UPD 090610
Cable Glands 653/UNIVERSAL
Mining 99
Flameproof Exd & Increased Safety Exe
Dual Certified ATEX / IECEx
• For use with single wire armour ‘W’, wire braid ‘X’, steel tape armour ‘Z’, Entry
Entry Thread
elastomer and plastic insulated cables.
• For particular use with:-
Ø 'D'
Ø 'E'
Ø 'B'
- Cables that are not effectively filled, compact and/or circular,
have tape bedding or have hygroscopic fillers.
- Cables that exhibit ‘Cold Flow’ characteristics.
- Enclosures containing an ignition source.
• See technical section for installation rules and regulations.
Ordering Information
Format for ordering is as follows: Alternative Seal (AR), add suffix AR to ordering information.
Cable Gland Type Size Thread (Optional) Cable Gland Type Size Thread (Optional)
653/UNIV C M32 AR 653/UNIV C 1 1⁄4"NPT AR
Two part sealing compound and assembly instructions are supplied with the cable gland.
Connection Solutions
HPG01
www.ehawke.com
UPD 090610
653/T Cable Glands
100
Mining
Flameproof Exd & Increased Safety Exe
Dual Certified ATEX / IECEx
Ø 'B'
have tape bedding or have hygroscopic fillers.
- Cables that exhibit ‘Cold Flow’ characteristics.
- Enclosures containing an ignition source.
• See technical section for installation rules and regulations
CABLE GLAND SELECTION TABLE
Entry Thread Size Cable Acceptance Details Hexagon Dimensions
Ordering Information
Format for ordering is as follows:
Cable Gland Type Size Thread Cable Gland Type Size Thread
653/T C M32 653/T C 1 1⁄4"NPT
Two part sealing compound and assembly instructions are supplied with the cable gland.
Connection Solutions
www.ehawke.com HPG01
UPD 090610
Accessories Stopping Plug:
Mining
Flameproof Exd & Increased Safety Exe
M475 & M477 101
'V'
Cert Detail
'X'
'V'
'X'
Markings
On This Face
Application
'L'
• Mining.
'W'
SELECTION TABLE • See technical section for installation rules and regulations
Features
Thread Size Hex. Key across Flats
Metric x 1.5p NPT * Size 'V' • To close unused cable gland entries and maintain the flameproof
integrity of the equipment.
M20
M25
½"
¾"
10.0
10.0
• Manufactured in Brass (standard), Nickel Plated Brass or
316 Stainless Steel.
M32 1" 10.0 • M475 is fitted from the outside of the enclosure.
M40 1¼" 10.0 • M477 is fitted from the inside of the enclosure.
M50 1½" 10.0 Technical Data
M63 2" or 1½" 10.0 • Flameproof Exd & Increased Safety Exe I M2.
M75 3" 10.0 • Certificate No’s: Sira 06ATEX1240U.
All dimensions in millimetres (except * where • Suitable for use in Mines.
dimensions are in inches). • Construction and Test Standards: IEC/EN 60079-0, IEC/E60079-1
and IEC/EN 60079-7.
• Operating Temperature Range: -60°C to +80°C.
Ordering Information Stopping Plug Type Size • Assembly Instruction Sheet: AI 379.
Format for ordering is as follows: M475 M32 • Alternative certification options available: GOST R-Exe IIU
'T' 'N'
'S'
'R'
470
'M'
'U'
'K'
Application
• Mining.
'L' 'N'
• See technical section for installation rules and regulations
Features
SELECTION TABLE
Size Flange Dimensions
• To close unused cable gland entries and maintain the flameproof
Ref. K L M N P R S T U integrity of the equipment.
O 44.4 12.7 19.05 26.1 6.7 11.1 7.0 30 70.0 • Manufactured in Brass (standard), Nickel Plated Brass or
316 Stainless Steel.
A 44.4 12.7 19.05 26.1 6.7 11.1 7.0 30 70.0
B 57.1 12.7 25.40 26.1 6.7 11.1 7.0 36 82.5
Technical Data
C 69.8 14.3 31.75 27.7 9.1 15.1 8.7 46 98.4 • Flameproof Exd I M2.
C2 82.5 14.3 38.10 27.7 9.1 15.1 8.7 55 111.1 • Certificate No’s: Baseefa08ATEX0333U and IECEx BAS 08.0013U
• Suitable for use in Mines.
D 95.2 17.5 50.80 29.3 11.1 18.1 10.5 65 130.2
• Construction and Test Standards: IEC/EN 60079-0 and IEC/EN 60079-1.
E 114.3 17.5 63.50 29.3 11.1 18.1 10.5 80 149.3
• Operating Temperature Range: -60°C to +80°C.
F 127.0 17.5 76.20 32.5 11.1 20.5 13.5 95 162.0 • Assembly Instruction Sheet: AI 345.
SELECTION TABLE
Equipment Entry Hole Size
• Alternative certification options available: GOST R-Exe IIU
Size Ref. Ordering Information
Max Min
O/A 19.35 19.10 Format for ordering is as follows:
B 25.70 25.45
Blanking Flange Type Size Blanking Flange Type Size
C 32.05 31.80
C2 38.40 38.15 470 C 470 C
D 51.10 50.85
E 63.80 63.55
F 76.50 76.25
All dimensions in millimetres.
Connection Solutions
www.ehawke.com
UPD 160913
Adaptor Flange Cable Glands
Mining
102
Type: 483 Flameproof Exd & Increased Safety Exe
Dual Certified ATEX / IECEx
'T' 'N'
'S'
'R'
'P'
'K'
'U'
'W'
'M'
'V'
Application
• Mining.
• See technical section for installation rules and regulations
'L' Features
'N'
• To allow metric threaded Group 1 cable gland types: 653/UNIV,
SELECTION TABLE 653/T, 653, 623, 453/UNIV, 453/T, 453/RAC and 453 to be used in
Equipment Entry Hole Size size up spigot entries.
Size Ref.
Max Min • Manufactured in Brass (standard), Nickel Plated Brass or
O 25.70 25.45 316 Stainless Steel.
A 25.70 25.45 Technical Data
B 32.05 31.80 • Flameproof Exd I M2.
C 38.40 38.15 • Certificate No’s: Baseefa08ATEX0333U and IECEx BAS 08.0013U
C2 51.10 50.85 • Suitable for use in Mines.
D 63.80 63.55 • Construction and Test Standards: IEC/EN 60079-0 and
IEC/EN 60079-1.
E 76.50 76.25
• Operating Temperature Range: -60°C to +80°C.
F 76.50 76.25 • Assembly Instruction Sheet: AI 344.
All dimensions in millimetres. • Alternative certification options available:
GOST R-Exe IIU
SELECTION TABLE
Flange Dimensions Casting
Size Ref.
K L M N P R S T U V W Size
O 57.1 12.7 25.40 26.1 6.7 11.1 7.0 36 82.5 M20 20.0 B
A 57.1 12.7 25.40 26.1 6.7 11.1 7.0 36 82.5 M20 20.0 B
B 69.8 14.3 31.75 27.7 9.1 15.1 8.7 46 98.4 M25 25.4 C
C 82.5 14.3 38.10 27.7 9.1 15.1 8.7 55 111.1 M32 32.0 C2
C2 95.2 17.5 50.80 29.3 11.1 18.1 10.5 65 130.2 M40 40.0 D
D 114.3 17.5 63.50 29.3 11.1 18.1 10.5 80 149.3 M50 50.7 E
E 127.0 17.5 76.20 32.5 11.1 20.5 13.5 95 162.0 M63 63.4 F
F 127.0 17.5 76.20 48.0 11.1 20.5 13.5 95 162.0 M75 66.0 F
All dimensions in millimetres.
Ordering Information
Format for ordering is as follows:
Adaptor Flange Type Size Adaptor Flange Type Size
483 C 483 C
A 484 Flanged Adaptor option is also available which allows metric threaded Group 1 cable gland types 653/UNIV, 653/T, 653, 623, 453/UNIV, 453/T, 453/RAC
and 453 to be fitted into a size for size spigot entry.
Connection Solutions
www.ehawke.com HPG01
Cable Glands - 103
Connection Solutions
www.ehawke.com HPG01
Cable Glands 710
North American Cable Glands/Connectors 105
Explosion Proof
IECEx and ATEX Approved Flameproof Exd,
Increased Safety Exe and Restricted Breathing ExnR
(Note: Dual Marked UL & ATEX as standard).
'G' Approx (Fully Compressed Length)
Compound
Application
• Outdoor or indoor use.
Entry Thread
• For use with non-armoured cable, as permitted by the NEC.
Ø 'D'
Ø 'B'
Ø 'E'
• See technical section for installation rules and regulations.
CABLE GLAND SELECTION TABLE
Entry Thread Size Cable Acceptance Details Hexagon Dimensions
Size Ref. NPT Metric * Inner Jacket / Cores Outer Jacket 'B' 'G' Across Flats Across
Standard Max. Over Max Inner Max. No. of
Min. Max. Corners
or Option Cores ‘D’ Jacket ‘E’ Cores
Os ½" M20¹ 0.35" 0.39" 6 0.22" 0.47" 2.55" 0.94" 1.04"
O ½" M20¹ 0.35" 0.39" 6 0.37" 0.63" 2.55" 0.94" 1.04"
A ½" or ¾" M20 0.43" 0.64" 10 0.49" 0.81" 2.59" 1.18" 1.28"
B ¾" or1" M25 0.64" 0.93" 21 0.66" 1.02" 2.80" 1.42" 1.56"
C 1" or 1¼" M32 0.86" 1.23" 42 0.87" 1.30" 2.99" 1.81" 1.99"
C2 1¼" or 1½" M40 1.04" 1.59" 60 1.10" 1.61" 3.18" 2.17" 2.36"
D 2" or 1½" M50 1.46" 1.96" 80 1.42" 2.07" 3.60" 2.56" 2.79"
E 2½" or 2" M63 1.88" 2.55" 100 1.81" 2.57" 3.59" 3.15" 3.46"
F 3" or 2½" M75 2.32" 2.98" 120 2.24" 3.07" 3.99" 3.74" 4.09"
H² 3½" M90 2.79" 3.12" 120 3.07" 3.52" 3.54 4.18" 4.84"
All dimensions in inches (except * where dimensions are in millimetres). Os - F size metric entry threads are 1.5mm pitch as standard, 15mm length of
thread. For H size glands, a 2mm pitch is supplied as standard, 20mm length of thread (1.5mm pitch with 15mm length of thread can be supplied) please
specify when ordering
¹ Sizes Os and O are available with an M16 thread size. For O size with M16 thread, the maximum cable inner jacket diameter is 0.43”.
² UL approved only
Ordering Information
Format for ordering is as follows:
Cable Gland / ConnectorType Size Thread
710 C 1"NPT
Two part sealing compound and assembly instructions are supplied with the cable gland.
Connection Solutions
HPG01
www.ehawke.com
UPD 090610
711 (& 713) Cable Glands
106
North American Cable Glands/Connectors
Explosion Proof
IECEx and ATEX Approved Flameproof Exd,
Increased Safety Exe and Restricted Breathing ExnR
'G' Approx (Fully Compressed Length) (Note: Dual Marked UL & ATEX as standard).
Compound Deluge Boot
Application
A
Entry Thread
Ø 'B'
Ø 'E'
• For use with continuous corrugated aluminium Metal Clad (MCHL) cable.
• See technical section for installation rules and regulations.
¹ UL approved only.
Ordering Information
Format for ordering is as follows:
Cable Gland / Connector Type Size Thread
711 C 1" NPT
Two part sealing compound and assembly instructions are supplied with the cable gland.
Connection Solutions
www.ehawke.com HPG01
UPD 090610
Cable Glands 753
North American Cable Glands/Connectors 107
Explosion Proof
IECEx and ATEX Approved Flameproof Exd,
Increased Safety Exe and Restricted Breathing ExnR
(Note: Dual Marked UL & ATEX as standard). 'G' Approx (Fully Compressed Length)
Nickel Plated Compound Braid 'C'
Hub
Application
• Outdoor or indoor use.
Entry Thread
• For use with braid armoured marine shipboard jacketed or
Ø 'B'
Ø 'D'
Ø 'E'
non-jacketed cable.
• See technical section for installation rules and regulations.
CABLE GLAND SELECTION TABLE
Entry Thread Size Cable Acceptance Details Hexagon Dimensions
Size NPT * Inner Jacket / Cores Outer Jacket 'B'
Braid ‘C’ 'G' Across Across
Ref. Standard Metric Max. Over Max Inner Max. No. of
Min. Max. Flats Corners
or Option Cores ‘D’ Jacket ‘E’ Cores
Os ½" M20² 0.35" 0.46" 6 0.22" 0.47" 0.008" / 0.013" 2.61" 0.94" 1.09"
O ½" M20² 0.35" 0.46" 6 0.37" 0.63" 0.008" / 0.013" 2.61" 0.94" 1.09"
A ½" or ¾" M20 0.43" 0.49" 10 0.49" 0.81" 0.008" / 0.013" 2.65" 1.18" 1.36"
B ¾" or 1" M25 0.64" 0.72" 21 0.66" 1.02" 0.008" / 0.013" 2.75" 1.42" 1.64"
C 1" or 1¼" M32 0.86" 0.97" 42 0.87" 1.30" 0.008" / 0.013" 2.93" 1.81" 2.09"
C2 1¼" or 1½" M40 1.04" 1.16" 60 1.10" 1.61" 0.008" / 0.013" 3.15" 2.17" 2.50"
D 2" or 1½" M50 1.46" 1.64" 80 1.42" 2.07" 0.008" / 0.013" 3.14" 2.56" 2.96"
E 2½" or 2" M63 1.88" 2.11" 100 1.81" 2.57" 0.008" / 0.013" 3.42" 3.15" 3.64"
F 3" or 2½" M75 2.32" 2.61 / 2.57" ¹ 120 2.24" 3.07" 0.008" / 0.013" 3.61" 3.74" 4.31"
H³ 3½" M90 2.79" 3.05" 120 3.07" 3.52" 0.008" / 0.013" 3.54" 4.18" 4.84"
All dimensions in inches (except * where dimensions are in millimetres). Os - F size metric entry threads are 1.5mm pitch as standard, 15mm length of
thread. For H size glands, a 2mm pitch is supplied as standard, 20mm length of thread (1.5mm pitch with 15mm length of thread can be supplied) please
specify when ordering
Ordering Information
Format for ordering is as follows:
Cable Gland / Connector Type Size Thread
753 C 1" NPT
Two part sealing compound and assembly instructions are supplied with the cable gland.
Connection Solutions
HPG01
www.ehawke.com
UPD 090610
755 Cable Glands
108
North American Cable Glands/Connectors
Explosion Proof
IECEx and ATEX Approved Flameproof Exd,
Increased Safety Exe and Restricted Breathing ExnR
(Note: Dual Marked UL & ATEX as standard).
'G' Approx (Fully Compressed Length)
Nickel Plated Compound Armour 'C'
Hub
Application
• Outdoor or indoor use.
Entry Thread
Ø 'B'
• See technical section for installation rules and regulations.
Connection Solutions
www.ehawke.com HPG01
UPD 090610
Cable Glands 153/X
North American Cable Glands/Connectors 109
General Purpose
Entry Thread
• For use with armoured marine shipboard jacketed or
Ø 'A'
Ø 'B'
non-jacketed cable.
• See technical section for installation rules and regulations.
CABLE GLAND SELECTION TABLE
Entry Thread Size Cable Acceptance Details Hexagon Dimensions
Size Standard Seal Alternative Seal (S) Outer Jacket ‘B’
NPT Standard 'G' Across Across
Ref. Metric * Braid ‘C’
or Option Min. Max. Min. Max. Min. Max. Flats Corners
Os ½" M20² 0.12" 0.31" - - 0.22" 0.47" 0.008" / 0.013" 2.04" 0.94" 1.04"
O ½" M20² 0.30" 0.46" - - 0.37" 0.63" 0.008" / 0.013" 2.04" 0.94" 1.04"
A ½" or ¾" M20 0.44" 0.56" 0.34" 0.52" 0.49" 0.81" 0.008" / 0.013" 2.08" 1.18" 1.28"
B ¾" or 1" M25 0.52" 0.79" 0.38" 0.60" 0.66" 1.02" 0.008" / 0.013" 2.74" 1.42" 1.55"
C 1" or 1¼" M32 0.75" 1.04" 0.61" 0.83" 0.87" 1.30" 0.008" / 0.013" 2.52" 1.81" 1.98"
C2 1¼" or 1½" M40 0.99" 1.27" 0.87" 1.10" 1.10" 1.61" 0.008" / 0.013" 2.69" 2.17" 2.38"
D 2" or 1½" M50 1.24" 1.74" / 1.67" ¹ 1.09" 1.37" 1.42" 2.07" 0.008" / 0.013" 3.11" 2.56" 2.78"
E 2½" or 2" M63 1.68" 2.21" / 2.14" ¹ 1.54" 1.83" 1.81" 2.57" 0.008" / 0.013" 3.10" 3.15" 3.46"
F 3" or 2½" M75 2.15" 2.67" / 2.57" ¹ 1.91" 2.29" 2.24" 3.07" 0.008" / 0.013" 3.29" 3.74" 4.09"
H 3½" or 3" M90 2.64" 3.06" - - 2.96" 3.52" 0.008" / 0.013" 4.80" 4.53" 5.23"
All dimensions in inches (except * where dimensions are in millimetres). Os - F size metric entry threads are 1.5mm pitch as standard, 15mm length of
thread. For H size glands, a 2mm pitch is supplied as standard, 20mm length of thread (1.5mm pitch with 15mm length of thread can be supplied) please
specify when ordering
Ordering Information
Format for ordering is as follows: Alternate Clamping Ring (S), add suffix S to ordering information.
Cable Gland / Size Thread (OPTIONAL) Cable Gland / Size Thread (OPTIONAL)
Connector Type Connector Type
153 CX M32 S 153 CX 1"NPT S
Connection Solutions
HPG01
www.ehawke.com
UPD 090610
701 Cable Glands
110
North American Cable Glands/Connectors
General Purpose
Ø 'B'
Metal Clad MC and Teck type cables.
• See technical section for installation rules and regulations.
Ordering Information
Format for ordering is as follows:
Connection Solutions
www.ehawke.com HPG01
UPD 090610
Cable Glands - 111
Industrial
Features Cable Glands
112
Industrial
Connection Solutions
www.ehawke.com HPG01
Cable Glands 121
Industrial 113
15.0mm (Fully Compressed Length)
'G' Approx
Metric
Entry
Entry Thread
Application
Ø 'B'
• Outdoor or indoor use.
• For use with non-armoured elastomer and plastic insulated cables.
Connection Solutions
HPG01
www.ehawke.com
UPD 090610
123 Cable Glands
114
Industrial
Ø 'B'
• May be used on cables incorporating inner and outer cable sheath at
two independent sealing points.
Connection Solutions
www.ehawke.com HPG01
UPD 090610
Cable Glands 153/UNIVERSAL
Industrial 115
• For use with single wire armour ‘W’, wire braid ‘X’, aluminium strip
Entry Thread
armour‘Y’, and steel tape armour‘Z’elastomer and plastic insulated cables.
Ø 'B'
Ø 'A'
• For particular use with:-
• Cables that exhibit ‘Cold Flow’ characteristics.
Ordering Information
Format for ordering is as follows: Alternate Seal (AR), add suffix AR to ordering information.
Cable Gland Type Size Thread (OPTIONAL) Cable Gland Type Size Thread (OPTIONAL)
153/UNIV C M32 AR 153/UNIV C 1 1⁄4"NPT AR
Connection Solutions
HPG01
www.ehawke.com
UPD 090610
153/RAC Cable Glands
116
Industrial
Application
Applicati
Entry Thread
• Ou
Outd
Outdoor
tdoo
oorr or indoor use.
Ø 'A'
• FForor uusese wwith single wire armour ‘W’, wire braid ‘X’, aluminium strip armour‘Y’
Ø 'B'
and steel tape armour ‘Z’ elastomer and plastic insulated cables.
Ordering Information
Format for ordering is as follows: Alternate Clamping Ring (AR), add suffix AR to ordering information. Alternate Seal (S), add suffix S
to ordering information.
Cable Gland Type Size Thread (OPTIONAL) Cable Gland Type Size Thread (OPTIONAL)
153/RAC C M32 AR 153/RAC C 1 1⁄4"NPT AR
153/RAC C M32 S 153/RAC C 1 1⁄4"NPT S
Connection Solutions
www.ehawke.com HPG01
UPD 090610
Cable Glands 153/RAC/L
Industrial ((for
o Lead
ead Sheath
S eat Cab
Cables)
es) 117
Entry Thread
• For use with single wire armour ‘W’, wire braid ‘X’, aluminium strip
Ø 'A'
Ø 'B'
armour ‘Y’ and steel tape armour ‘Z’ elastomer and plastic insulated
cables.
Ordering Information
Format for ordering is as follows: Standard Inner Seal + Bond, add suffix L to ordering information. Alternative Inner Seal + Bond, add suffix K
to ordering information. Alternative Clamping Ring (AR), add suffix AR to ordering information.
Cable Gland Size Thread Lead (OPTIONAL) Cable Gland Size Thread Lead (OPTIONAL) Cable Gland Size Thread Lead (OPTIONAL)
Type Type Type
153/RAC C M32 L AR 153/RAC C 1 1⁄4"NPT L AR 153/RAC C 1 1⁄4"NPT K AR
Connection Solutions
HPG01
www.ehawke.com
UPD 090610
150/RAC Cable Glands
118
Industrial
Application
Entry Thread
• Indoor use.
Ø 'A'
Ø 'B'
• For use with single wire armour ‘W’, wire braid ‘X’, aluminium strip
armour ‘Y’ and steel tape armour ‘Z’ elastomer and plastic insulated cables.
Ordering Information
Format for ordering is as follows: Alternative Clamping Ring (AR), add suffix AR to ordering information.
Cable Gland Type Size Thread (OPTIONAL) Cable Gland Type Size Thread (OPTIONAL)
150/RAC C M32 AR 150/RAC C 1 1⁄4"NPT AR
Connection Solutions
www.ehawke.com HPG01
UPD 090610
Cable Glands 151/RAC
Industrial 119
Entry Thread
• For use with single wire armour ‘W’, wire braid ‘X’, aluminium strip
Ø 'A'
Ø 'B'
armour ‘Y’ and steel tape armour ‘Z’ elastomer and plastic insulated cables.
Ordering Information
Format for ordering is as follows: Alternative Clamping Ring (AR), add suffix AR to ordering information.
Cable Gland Type Size Thread (OPTIONAL) Cable Gland Type Size Thread (OPTIONAL)
151/RAC C M32 AR 151/RAC C 1 1⁄4"NPT AR
Connection Solutions
HPG01
www.ehawke.com
UPD 090610
114 Cable Glands
120
Industrial
Metric
Entry
Application
Female Entry
Entry Thread
Thread
Male
Ø 'B'
installed in conduit.
¹ Smaller value is applicable when selecting reduced NPT male entry option.
# NPT female thread sizes equivalent to those shown in the table for the male thread size are available. Hexagon dimensions as shown may alter.
Cable Gland Type Size Thread (OPTIONAL) Cable Gland Type Size Thread (OPTIONAL)
114/RAC C M32 AR 114/RAC C 1 1⁄4"NPT AR
Connection Solutions
www.ehawke.com HPG01
UPD 090610