Location via proxy:   [ UP ]  
[Report a bug]   [Manage cookies]                

Tender Document: Installation of 20 KWP Stand Alone SPV SOLAR Power Plant at SBBJ STC Bikaner

Download as pdf or txt
Download as pdf or txt
You are on page 1of 19

Installation of 20 KWP Stand Alone SPV SOLAR

POWER PLANT AT SBBJ STC BIKANER

TENDER DOCUMENT

STATE BANK OF BIKANER AND JAIPUR


PREMISES DEPARTMENT, HEAD OFFICE
TILAK MARG, JAIPUR – 302005

1
Brief Details of the Tender

Earnest Money Deposit (EMD) : Rs.30,000/- (Rupees Thirteen Thousand


only) in the form of Demand Draft in
favor of State Bank of Bikaner and
Jaipur payable at Jaipur (EMD should be
submitted in separate sealed envelope
super scribing the name)

Validity of Tender : 45 Days from the date of opening of


tender.

Last Date of submission of Sealed : 08-09-2015 at 2:00 PM


Tender
Dated of Opening of Tender : 08-09-2015 at 4:00 PM

Period of Completion : 10 Days

Defects Liability Period : 12 (Twelve) Months from the date of


Virtual Completion

Agreed Liquidated Damages : a) 1.0% of the contract value for each


week of delay.

Subject to maximum of 10% of the


contract value.

Estimated cost of work : Rs. 15 lakhs.( Rupees fifteen lakhs only )

Cost of Tender : Rs. 1000/- ( One thousand only)

The Bank is not bound to accept the lowest tender/ offer/ quotation and
reserve the right accept or reject any or all the tenders/ quotations
without assigning any reasons whatsoever.

2
STATE BANK OF BIKANER AND JAIPUR
PREMISES DEPARTMENT, H.O. JAIPUR

Date:
19.08.2015
Dear Sir/s,

INSTALLATION OF 20 KW SOLAR POWER PLANT AT SBBJ


STC BIKANER

NOTICE OF INVITATION TO TENDER

Sealed tenders on item rate basis are invited from the competent enlisted
CONTRACTORS with MNRE in the appropriate category, who has worked for
installation of solar power plants of similar nature in various organizations having
sound technical and financial capacity for the aforesaid work. The proof of the similar
works from the concerned organization must be submitted along-with the tender.
Tender document may be downloaded from Bank’s web-site
(http://www.sbbjbank.com) as well as Govt’s web-site (http.//www.tenders.gov.in) and
can also be obtained from the office of the undersigned. While submitting tender, a
crossed Demand Draft of Rs. 1000/- (One Thousand only) (Non – refundable) is to
be enclosed against cost of the tender in the favor of AGM(Premises),SBBJ HO
Jaipur.

Estimated cost of the Work : Rs. 15 lakhs.

Earnest Money : Rs. 30,000/- (Rupees Thirty Thousand only)


in the form of Demand Draft in favour of
State Bank of Bikaner and Jaipur payable at
Jaipur
Place where tenders to be : The Assistant General Manager,
submitted Premises, State Bank of Bikaner &
Jaipur, Head Office, Tilak Marg,
Jaipur – 302005.

Time and date of submission of : Upto 2.00 P.M. on 08.09.2015


Tender

Time and date of opening of : 4.00 PM on 08.09.2015


tenders

Assistant General Manager,


Premises.

3
LVsV cSad vkWQ chdkusj ,.M t;iqj
ifjlj foHkkx] iz/kku dk;kZy;] t;iqj

STC BIKANER ब्रांच मे 20 kwp सोलर परवर पैक की आपूर्ति व स्थरपनर हे तु

mDr dk;Z djus gsrq MNRE मे रजिस्टर्ड उपयुक्त Bsdsnkjksa ls eksgjcan fufonk vkeaf=r dh tkrh

gSA Ñi;k laca/kh izek.k i= layXu djsaA


fufonk dk fooj.k gekjs cSad ds oSclkbV (http://www.sbbjbank.com) vFkok ljdkj ds oSclkbV
(http.//www.tenders.gov.in) ls yh tk ldrh gSA fufonk Hkjr le; VsaMj ds lkFk :- 1000@&
dk fMekaM Mªk¶V yxkuh gSA

1- vuqekfur ykxr % :- 15 yk[k

2- /kjksgj jkf’k % :- 30000@&

3- fufonk tgk¡ Mkyh tkuh gS % ifjlj foHkkx] iz/kku dk;kZy;] t;iqj

4- fufonk Mkyus dh vafre frfFk% 08.09.2015 vijkg~u 2-00 cts rd

5- fufonk [kksyus dh frfFk % 08.09.2015 vijkg~u 4-00 cts

6- dk;Z iw.kZ djus dk le; % 10 दिन

lgk;d egkizca/kd ¼ifjlj½

4
GENERAL RULES AND INSTRUCTIONS FOR THE GUIDANCE OF
TENDERERS

1. Tenders are hereby invited on behalf of State Bank of Bikaner & Jaipur, Iaipur
for PROPOSED Installation of 20 KWP Stand Alone SPV SOLAR POWER
PLANT AT SBBJ STC BIKANER.

2. Contract documents consist of Pro-forma for Pre-qualification, detailed


plans, technical specification, schedule of quantities of the various
classes of work to be done, and the set of ‘conditions of contract’ to be
complied with by the person whose tender may be accepted. Tender
documents may be downloaded from the Bank’s web –site
(http://www.sbbjbank.com) as well as Govt’s web-site
(http://www.tenders.gov.in) or can also be obtained from the office
of the undersigned. While submitting tender, a crossed Demand
Draft for Rs. 1000/- (One thousand only) (Non- refundable) is to be
enclosed against cost of the tender, payable at JAIPUR during the
office hours on working days. Therefore, contractors are advised to
visit the site before quoting the rates.

3. Tenders which should always be placed in two envelopes, with the


name of the project written on the envelopes will should contain
Earnest Money Deposit, Tender Fee, Pre-qualification forms,
conditions of contract and technical specifications. Envelope-2 should
contain Price bid. The decision of the committee regarding
prequalification of contractors shall be final.

4. The time allowed for carrying out of the work will be 10 Days only.

5. The contractors should quote in figures as well as in the words the


rates and amount tendered by them. The amount for each item should
be worked out and the requisite totals given. Rates quoted by the
contractor in item rate tender in figures and words shall be accurately

5
filled in so that there is no discrepancy in the rates, figures and words.
However, if a discrepancy is found in the rates, which correspond with
the amount worked out by the contractor shall be taken as correct. If
the contractor does not work out the amount of an item or it does not
correspond with the rate written either in figure or in words then the
rates quoted by the contractor in words shall be taken as correct.
Where the rates quoted by the contractor in figures and in words tally
but the amount is not worked out correctly the rates quoted by the
contractor will be taken as correct and not the amount.

6. The tender document must be filled in English and all the entries must
be made by the hand and written in ink. If any of the documents are
missing or un-signed, the tender shall be considered invalid.

7. Issue of tender form will be stopped one day before the date fixed for
the opening of tenders.

8. Earnest money amounting to Rs.30,000/- (Rupees Thirty Thousand


Only) in the form of bank draft drawn in favor of State Bank of Bikaner
and Jaipur, must accompany with each tender and each tender is to be
in a sealed cover super scribed “TENDER FOR PROPOSED solar
works.”

9. The Contractor, whose tender is accepted, will be required to furnish by


way of initial security deposit for the due fulfillment of his contract, such
sum as will amount to 2.00% of the estimated cost of work. The S.D.
shall be collected as detailed in the general conditions of the contract.
The EMD of the contractor, whose tender is accepted, shall be forfeited
in full in case he does not remit the Initial Security Deposit within the
stipulated period or start the work by the stipulated date mentioned in
the award letter.

10. The acceptance of tender will rest with the State Bank of Bikaner &
Jaipur which does not bind itself to accept the lowest tender, and
reserves to itself, the authority to reject any or all of the tenders

6
received without the assignment of a reason. All tenders in whom any
of the prescribed, conditions are not fulfilled or are incomplete in any
respect are liable to be rejected.

The Bank reserves the right to accept the tender in full or in part and
the tenderer shall have no claim for revision of rates or other
conditions, if his tender is accepted in parts.

11. Canvassing in connection with tenders is strictly prohibited and the


tenders submitted by the contractors who resort to canvassing will be
liable to rejection.

12. All rates shall be quoted on the proper form of the tender alone.

13. Tender containing any condition leading to unknown / indefinite liability,


are liable to be summarily rejected. If at all any rebate(s) is/are to be
offered the tenderer shall first quote his rates strictly on the terms and
conditions stipulated in tender document and then show separately
rebate(s) offered specifying the conditions for such rebate(s). Failure to
follow this procedure will render the tender liable to summarily
rejection.

14. All compensation or other sums of money payable by the Contractor to


Clients under the terms of this contract may be deducted from the
security deposit, or from any sum that may be or may become due to
the Contractor on any account whatsoever and in the event of the
Security Deposit being reduced by reasons of any such deductions, the
Contractor shall within --- days of being asked to do make good in cash
or by cheque any sum which have been deducted from his security
deposit.

15. On acceptance of the tender, the name of the accredited


representatives(s) of the contract or who would be responsible for
taking instructions from the Employer/ shall be communicated to the
Employer.

7
16. Special care should be taken to write the rates in figures as well as in
words and the amounts in figures only, in such a way that interpolation
is not possible. The total amount should be written both in figures and
in words. In case of figures, the words "Rs." should be written before
the figures, e.g. Rs.2.15. and in case of word Rupees should precede
and the word ‘Paise’ should be written at the end, unless the rate is in
whole rupees and followed by the words 'only'. it should invariable be
up to two decimal places. While quoting the rate is in schedule of
quantities the word 'only' should be written closely following the amount
and it should not be written in the next line.

17. Sales Tax or any other tax on material or on finished works like work's
contract tax, Service Tax, Turn - over etc. in respect of this contract
shall be payable by the contractor and the Bank will not entertain any
claim whatsoever in this respect .

18. The contractor shall give a list of his relatives working with the Bank
along with their designations and addresses.

19. No employee of the bank is allowed to work as a contractor for a period


of two years of his retirement from Bank service, without the previous
permission of the bank. This contract is liable to be cancelled if either
the contractor or any of his employees is found at any time to be such
a person who has not obtained the permission of the Bank as aforesaid
before submission of the tender or engagement in the contractor's
service.

20. The tender for works shall remain open for acceptance for a period of
45 (Forty Five) days from the date of opening of tenders. If any
tenderer withdraws his tender before the said period, then the bank
shall be at liberty to forfeit Earnest Money paid along with the tender.

21. The tender for the work shall not witness by a contractor or contractors
who himself/themselves have/have tendered or who may and had/have
tendered for the same work. Failure to observe this condition would

8
render tenders of the contractors tendering as well as witnessing the
tender liable to summary rejection.

22. It will be obligatory on the part of the tenderer to tender and sign the
tender documents for all the component parts and that, after the work
is awarded, he will have to enter into an agreement for each
component with the competent authority in the bank.

23. The tender, apart from being a competent contractor must associate
himself with agencies of the appropriate class who are eligible to
tender for (i) electrical (ii) Air-conditioning work

24. The tenderer should visit the site to ascertain the working conditions
and local authority regulations / restrictions if any and other information
required for the proper execution of the work.

25. The quantities of various items given in the schedule of quantities are
approximate. The quantities of work may vary at time of allotment /
execution of work. Bank reserves the right to omit / delete any item(s)
of work from the schedule at the time of allotment / before. Contractor
will be paid for the actual work done at the site duly verified by the
concerned official of the bank.

26. The unit price shall be deemed to be fixed price. In case of extra items,
a record of labor charges paid shall be maintained and shall be
presented regularly to the Employers for checking. The settlement will
be made based on figures arrived at jointly and taking unit price given
in the contract assigned to the successful Tenderer. In case of extra
items where similar or comparable items are quoted in the tender, extra
rates shall be based on tender rates.

27. If the rate quoted by the contractor for any item / items are not
workable or abnormally lower than the market rate, the bank may
demand Bank guarantee from the contractor for satisfactory completion
of these work. The bank guarantee amount will be not less than 50% of
the estimated amount of the items for which the rates are not workable

9
or abnormally low. This bank guarantee will be released after
completion of these works (unworkable and abnormally low rated
items) to the satisfaction of the bank.
28. No employee of the Bank is allowed to work as a contractor for a
period of 2 years of his/her retirement from Bank Services without
previous permission of the Bank. This contract is liable to be cancelled,
if either the contractor or any of his employees is any time to be such a
person who had not obtained the permission of Bank as aforesaid
before submission of the tender or engagement in the contractor’s
service.
29. Sealed tenders in prescribed form in two envelopes (Envelope-1
should contain Earnest Money Deposit, in form of DD Drawn in favor of
State bank of Bikaner & Jaipur, Jaipur, Payable at Jaipur, Tender Fee
in form of DD of Rs.1000/- in favor of AGM Premises SBBJ HO .
Payable at Jaipur, Pre-qualification forms, conditions of contract and
technical specification. Envelope-2 should contain price bid. are to be
addressed and sent to The Assistant General Manager, Premises,
State bank of Bikaner & Jaipur, Head Office, Tilak Marg, Jaipur –
302005.
30. Estimated Cost: Rs.15,00,000/- -

10
TECHNICAL DETAILS

TO supply, install, testing & commissioning of a 20 KWp Stand Alone SPV


Power Plant at SBBJ, STC, BIKANER.

1. SPV MODULES:

Type and Quality

The total Solar PV Array Capacity shall be 20 KWp. Mono/Poly Crystalline type

solar modules of desired nominal voltage or peak power rating which meet

specifications are considered appropriate for inclusion in this offer. Modules will

be supplied by Vendor with a warranty that:

- Fabrication is in compliance with the standards approved by MNRE.

- 250/300 Wp or any other capacity modules shall be used.

- Offered module shall have a power output warranty for 25 years.

- Solar cells / modules used have a proven record for the performance in

actual field conditions of Rajasthan state. PV Modules have IEC 61215

certification.

The modules used shall have following specifications under STC:

Make : (Standards approved by MNRE)

Type : 250W60/300W72

Peak Power Output : 250/300 Watts

Maximum Current : 8.78 /8.78 A DC

Maximum Voltage : 30/34 VDC

Dimension in mm : 1658 x 997 x 42/ 1973 x 997 x 42

Type of Cell used : Mono/Poly Crystalline Silicon

2. MECHANICAL COMPONENTS

11
ARRAY SUPPORT STRUCTURE

Modules shall be mounted on a non-corrosive support structure

suitable for site conditions. The inclination angle of the array support structure

shall be in accordance with the latitude of the place of installation. No provision

for adjusting inclination angle is required. There shall be mild steel frame

structures (Hot dipped, Galvanized) for holding the PV modules to form the PV

panels Each panel frame structure shall be so fabricated as to be grouted using

cement concrete foundation by the Vendor complete in all respects.

Each panel frame shall be complete with a weather proof junction box as per the

relevant ISI specifications, where the module terminals shall be interconnected

and output taken.

The panel frame structure be capable of with standing a wind load of

200-250 km per hour, after grouting and installation. Accordingly the

design, installation and adjustments of the panels will be done by the

vendor.

3. POWER CONDITIONER UNIT (PCU)

12
The power-conditioning unit will convert dc power produced by SPV array

into AC power. The capacity of Centralized PCU shall be aggregate

capacity of 20 KVA, Bidirectional 3 phase input 3 phase output types.

The Inverter should have both grid tie and off tie functions built in. The

inverter has to be capable of exporting solar power to the grid. It should

not shut down during power outages. The Vendor will arrange the

metering arrangement for energy export in consultation with local

electrical distribution company.

ELECTRICAL

INVERTER

Max. No. of Series panels 10-20 nos.

AC out put voltage 415-420 volt,3 phase, 50 Hz

Maximum out put capacity 20 KVA

Peak out put capacity Up to 150% of maximum current for 15

seconds

Out put wave shape Sine wave

THD <5%

Max current ripple 4% peak to peak

No load power 2.5 % of O/p rating

consumption

Efficiency at 30 degree > 90%

centigrade

ENVIRONMENTAL

Cooling Temperature controlled fan forced cooling

Ambient temperature 0 deg to 55 deg

range

13
Ambient humidity range 5% to 90% condensing

Construction

The inverter shall be supplied in IP 20 indoor enclosure.

Protections:

Following protections shall be provided:

- Short Circuit

- Overload

- Input surge voltage

4. ARRAY JUNCTION BOXES

The junction boxes shall be provided in PV array field for termination of

connections from various arrays.

Features:

 Made of FRP

 Dust and vermin proof

 Suitable MOV’s shall be provided for high voltage surge

 Copper bus bars of suitable rating

5. CABLES

Cabling will be carried out as per IE rules and all should be ISI Marked.

Cable Marking: All cables/wires shall be marked with good quality ferule for

Cable identification.

Cable Ends: All connections shall be made through suitable cable lugs/tags

crimped properly and with the use of cable glands.

All cables shall be:-

 Multistrand , annealed high conductivity copper/aluminum conductor

 Overall PVC insulation for UV protection

 Armoured cables for under ground laying

14
 All cables shall conform to BIS standards

6. CIVIL WORK

Civil work shall include work related with foundation for installation of module

mounting structures and other accessories. However the Bank shall provide

clear space for installation of SPV array and the control room for

installation of PCU.

7. DANGER BOARDS AND SIGNALS

Danger boards should be provided as and where necessary.

8 LIGHTNING PROTECTION

The suitable lightning arrestors (ESE) installed in the array area. Lightning
protection be provided by the use of metal oxide arrestors and suitable earthing
such that induced transients find an alternate route to earth. Protection shall meet
the safety rules as per Indian Electricity Act 2003/IE rules.

9. EARTHING PROTECTION
Each array structure of the PV yard be grounded/ earthed properly. In addition
the lighting arrester/masts should also be provided inside the array field.
Provision be kept for shorting and grounding of the PV array at the time of
maintenance work. All metal casing/shielding of the plant be thoroughly grounded
in accordance with Indian Electricity Act/IE Rules when required after earthing by
calibrated earth tester. PCU and DCDB should also be earthed properly. Earth
resistance is not more than 5 ohms. It will be ensured that all the earthing points
are bonded together to make them at the same potential.

10. SURGE PROTECTION:

15
Internal surge protection are consist of three MOV type arrestors connected from
+ve and – ve terminals to earth (via Y arrangement) for higher withstand of the
continuous PV-DC voltage during earth fault condition. SPD have safe
disconnection and short circuit interruption arrangements through integrated DC
in-build bypass fuse (parallel) which get tripped during failure mode of MOV,
extinguishing DC arc safely in order to protect the installation against fire
hazards.

11. FIRE EXTINGUISHERS:

The fire fighting system for the proposed power plant for fire protection shall be
consisting of:
 Portable fire extinguishers in the control room for fire caused by electrical
short circuits.
The fire extinguishers shall be provided in the control room housing the PCU.

12. PROJECT DURATION

The work of supply & installation shall be completed within 1 month from the date

of sanction of the project and clear order received from beneficiary.

16
Qty/Rate

The bill of material for 20 KWp Grid connected SPV Power Plant is as under:

Rate Amount
Sr. No. Description of item Unit Quantity (Rs)

1. Solar PV Modules250/300 Wp Set 20 KWp

2. Mounting Structure Set 01 Set

3. Power Conditioning Unit Nos. 01No

(20 KVA)

4. Battery Bank Nil Nil

5. Array Junction Box Set 01 set

6. Earthing Set Set 01 set

7. Lightning Arrester Set 01 Set

8. Wires and Cables Set As per site

requirement

9. Installation accessories/tools Set 01 set

10. Fire- Fighting Equipment Set 01 Set

11. Danger and Sign Board Set 01 Set

Total

17
Terms & Conditions:

Price : FOR Site, Bikaner including installation-


commissioning
Charges and two year warranty maintenance.

Validity of Offer : One month.

Taxes/Duties :CST/ VAT at present nil. However, taxes if any, shall

be charged extra as per applicability at the time of

delivery.

Delivery : 15 days after clear techno-commercial order.

Payment : (1) 50 % after supply of material at site

(2) 25% after installation

(3) 20% after testing and commissioning.

(4) Remaining 5% will be kept as SD till DLP of one

year

Warranty : Five years from date of supply against manufacturing

Defects only and 2 years’ onsite maintenance

warranty.

Scope of work:

(a) SBBJ, Jaipur :

- Shall provide shadow free roof top area for installation of SPV Power

plant as per requirement,

- Shall arrange safe storage of material at respective site till

commissioning of systems,

- Shall provide covered space of Size 12 feet x 12 feet for control room

with proper ventilation.

18
(b) VENDOR:

- VENDOR shall provide power (from SPV Power Plant) at one point

only. CONTRACTOR scope of work includes site, survey, layout

planning, design, development and supply of all components of SPV

System, Transportation of SPV Power system up to central location, I

& C of SPV Power system, on site training of customer for routine visit

maintenance for Five years.

Checklist:--

1. Copy of Appropriate category empanelment from MNRE


2. Copy of experience certificates/ work orders and completion certificates
for works for Similar Nature and magnitude.
3. Proof of service centre at Bikaner and its details(Attested by notary)
4. Technical and Financial Bids separately sealed.
5. DD for EMD and Tender Cost Enclosed.
6. Tender documents are duly signed and sealed.

19

You might also like