Foundation Load (Reactions) Data FOR 45 M Diameter Thickener

Download as pdf or txt
Download as pdf or txt
You are on page 1of 88

Project : OCP Benguerir

Description : Foundation Load (Reactions) Data


Structure : 45m Diameter High Rate Thickeners
Doc. No. : 2689A0TR045VB101 Rev. : A
Client : OCP, Morocco

FOUNDATION LOAD (REACTIONS) DATA


FOR
45 M DIAMETER THICKENER

Document No: 2689A0TR045VB101 Project Number: 19-2689


Submission Status: Implementation / Use
IP Security: Company Confidential

Page 1
Project : OCP Benguerir
Description : Foundation Load (Reactions) Data
Structure : 45m Diameter High Rate Thickeners
Doc. No. : 2689A0TR045VB101 Rev. : A
Client : OCP, Morocco

Revision History:

Revision Date Status Originator Checked Approved


0 01/04/2019 Implementation / Use HR MSR NRM

Revision Description Sheet:

Rev. Para. Revision Description


A - Issued for Use

Page 2
Project : OCP Benguerir
Description : Foundation Load (Reactions) Data
Structure : 45m Diameter High Rate Thickeners
Doc. No. : 2689A0TR045VB101 Rev. : A
Client : OCP, Morocco

Table of Contents

1. Introduction ....................................................................................................................................... 4

1.1 Reaction Summary ..................................................................................................................... 4

1.2 Support Reactions – Columns-PCD1 ............................................................................................. 5

1.3 Support Reactions – Columns-PCD2 ........................................................................................... 19

1.4 Support Reactions – Columns-PCD3 ........................................................................................... 33

1.5 Support Reactions – Columns-PCD4 ........................................................................................... 47

1.6 Support Reactions – Columns-PCD5 ........................................................................................... 61

1.7 Support Reactions – Centre Column ........................................................................................... 75

List of Tables

Table 1: Summary of the Reactions – Primary Load Cases .............................................................................. 4

Page 3
Project : OCP Benguerir
Description : Foundation Load (Reactions) Data
Structure : 45m Diameter High Rate Thickeners
Doc. No. : 2689A0TR045VB101 Rev. : A
Client : OCP, Morocco

1. Introduction
This document provides the reactions at each support of centre column and at the supports of columns other than the centre column.

1.1 Reaction Summary


The following table summarizes the sum of the total reactions (for the whole structure) obtained from the STAAD.Pro analysis under each of the primary load cases. These
are the UNFACTORED reactions (not forces) and hence needs to be multiplied with a factor of ‘-1’ in order to obtain the forces.

Table 1: Summary of the Reactions – Primary Load Cases

Forces (kN) Moments (kNm)


Load Case Description Fx Fy Fz Mx My Mz
601 Dead Load 0.0 -4605.6 0.0 23.1 0.0 -2264.1
602 Live Load - Bridge Walkway 0.0 -980.3 0.0 18.6 0.0 -1457.3
603 Fluid Loads - Operating Condition -1.3 -91371.6 0.1 18.3 -4.5 -1942.9
604 Fluid Loads - Sanded Condition -1.4 -101081.6 0.1 18.4 -5.0 -1941.8
605 Live Load - Torque and Lifting - Normal Operating 0.0 0.0 0.0 0.0 764.4 0.0
606 Live Load - Torque and Lifting - Maximum 0.0 -210.0 0.0 0.0 2352.0 0.0
607 Wind Load - X Direction 0.0 0.0 778.6 5027.6 -999.3 0.0
608 Wind Load - Z Direction 745.2 0.0 0.0 0.0 5.5 -4593.4
609 Seismic Load - Z Positive Direction 0.0 0.0 13049.5 65489.8 -967.7 0.0
610 Seismic Load - Z Negative Direction 0.0 0.0 -13049.5 -65489.8 967.7 0.0
611 Seismic Load - X Positive Direction 13049.5 0.0 0.0 0.0 18.5 -65489.8
612 Seismic Load - X Negative Direction -13049.5 0.0 0.0 0.0 -18.5 65489.8
613 Seismic Load - Y Direction 0.0 0.0 0.0 0.0 0.0 0.0
614 Temperature Positive Gradient 0.0 0.0 0.0 0.0 0.0 0.0
615 Temperature Negative Gradient 0.0 0.0 0.0 0.0 0.0 0.0

Page 4
Project : OCP Benguerir
Description : Foundation Load (Reactions) Data
Structure : 45m Diameter High Rate Thickeners
Doc. No. : 2689A0TR045VB101 Rev. : A
Client : OCP, Morocco

1.2 Support Reactions – Columns-PCD1


Note: The following reactions shall invariably be considered with respect to the orientation indicated in the
snapshots in the following sections and shall be matched with the orientation of the thickener according to the
layout drawing.

Page 5
Project : OCP Benguerir
Description : Foundation Load (Reactions) Data
Structure : 45m Diameter High Rate Thickeners
Doc. No. : 2689A0TR045VB101 Rev. : A
Client : OCP, Morocco

Horizontal Vertical Horizontal

Node L/C Fx kN Fy kN Fz kN

7993 601 DEAD LOAD -2.375 102.607 10.833

602 LIVE LOAD - BRIDGE WALKWAY -1.267 66.401 6.386

603 FLUID LOADS - OPERATING CONDITION -33.204 638.663 115.002

604 FLUID LOADS - SANDED CONDITION -36.732 702.091 127.077

605 LIVE LOAD - TORQUE AND LIFTING - NORMAL OPERATING -0.196 1.202 0.73

606 LIVE LOAD - TORQUE AND LIFTING - MAXIMUM -0.608 3.708 2.264

607 WIND LOAD - Z DIRECTION 3.29 2.71 -11.35

608 WIND LOAD - X DIRECTION -2.083 143.026 11.161

609 SEISMIC LOAD - Z POSITIVE DIRECTION 68.393 -398.396 -254.39

610 SEISMIC LOAD - Z NEGATIVE DIRECTION -68.393 398.396 254.39

611 SEISMIC LOAD - X POSITIVE DIRECTION -24.581 494.99 93.647

612 SEISMIC LOAD - X NEGATIVE DIRECTION 24.581 -494.99 -93.647

613 SEISMIC LOAD - Y DIRECTION 0 0 0

614 POSITIVE THERMAL GRADIENT -6.009 -3.079 20.587

615 NEGATIVE THERMAL GRADIENT 6.009 3.079 -20.587

7994 601 DEAD LOAD 4.733 60.9 -17.129

602 LIVE LOAD - BRIDGE WALKWAY 2.988 39.549 -10.426

603 FLUID LOADS - OPERATING CONDITION 29.454 609.67 -120.514

604 FLUID LOADS - SANDED CONDITION 32.384 673.851 -132.587

605 LIVE LOAD - TORQUE AND LIFTING - NORMAL OPERATING -0.195 -1.22 0.731

606 LIVE LOAD - TORQUE AND LIFTING - MAXIMUM -0.597 -3.757 2.24

607 WIND LOAD - Z DIRECTION 7.556 53.803 -27.897

608 WIND LOAD - X DIRECTION -0.087 -113.495 -2.692

609 SEISMIC LOAD - Z POSITIVE DIRECTION 70.453 468.017 -265.877

610 SEISMIC LOAD - Z NEGATIVE DIRECTION -70.453 -468.017 265.877

611 SEISMIC LOAD - X POSITIVE DIRECTION -14.471 -333.486 42.428

Page 6
Project : OCP Benguerir
Description : Foundation Load (Reactions) Data
Structure : 45m Diameter High Rate Thickeners
Doc. No. : 2689A0TR045VB101 Rev. : A
Client : OCP, Morocco

612 SEISMIC LOAD - X NEGATIVE DIRECTION 14.471 333.486 -42.428

613 SEISMIC LOAD - Y DIRECTION 0 0 0

614 POSITIVE THERMAL GRADIENT 5.772 0.168 -23.257

615 NEGATIVE THERMAL GRADIENT -5.772 -0.168 23.257

7995 601 DEAD LOAD -6.379 45.872 6.495

602 LIVE LOAD - BRIDGE WALKWAY -3.592 30.015 3.809

603 FLUID LOADS - OPERATING CONDITION -85.389 589.899 81.614

604 FLUID LOADS - SANDED CONDITION -94.49 653.343 90.317

605 LIVE LOAD - TORQUE AND LIFTING - NORMAL OPERATING -0.535 1.216 0.534

606 LIVE LOAD - TORQUE AND LIFTING - MAXIMUM -1.659 3.749 1.657

607 WIND LOAD - Z DIRECTION 4.91 -13.992 -5.038

608 WIND LOAD - X DIRECTION -7.911 -11.834 7.435

609 SEISMIC LOAD - Z POSITIVE DIRECTION 136.132 -289.412 -137.481

610 SEISMIC LOAD - Z NEGATIVE DIRECTION -136.132 289.412 137.481

611 SEISMIC LOAD - X POSITIVE DIRECTION -147.805 294.953 144.639

612 SEISMIC LOAD - X NEGATIVE DIRECTION 147.805 -294.953 -144.639

613 SEISMIC LOAD - Y DIRECTION 0 0 0

614 POSITIVE THERMAL GRADIENT -15.367 -3.692 14.691

615 NEGATIVE THERMAL GRADIENT 15.367 3.692 -14.691

7996 601 DEAD LOAD 5.032 50.057 -4.853

602 LIVE LOAD - BRIDGE WALKWAY 2.911 32.575 -2.656

603 FLUID LOADS - OPERATING CONDITION 78.984 599.221 -82.875

604 FLUID LOADS - SANDED CONDITION 87.536 663.284 -91.844

605 LIVE LOAD - TORQUE AND LIFTING - NORMAL OPERATING -0.531 -1.21 0.532

606 LIVE LOAD - TORQUE AND LIFTING - MAXIMUM -1.626 -3.726 1.631

607 WIND LOAD - Z DIRECTION 4.261 9.245 -4.395

608 WIND LOAD - X DIRECTION -13.527 -2.128 13.712

609 SEISMIC LOAD - Z POSITIVE DIRECTION 140.852 352.541 -142.825

610 SEISMIC LOAD - Z NEGATIVE DIRECTION -140.852 -352.541 142.825

Page 7
Project : OCP Benguerir
Description : Foundation Load (Reactions) Data
Structure : 45m Diameter High Rate Thickeners
Doc. No. : 2689A0TR045VB101 Rev. : A
Client : OCP, Morocco

611 SEISMIC LOAD - X POSITIVE DIRECTION -151.571 -256.005 151.238

612 SEISMIC LOAD - X NEGATIVE DIRECTION 151.571 256.005 -151.238

613 SEISMIC LOAD - Y DIRECTION 0 0 0

614 POSITIVE THERMAL GRADIENT 16.683 0.42 -17.312

615 NEGATIVE THERMAL GRADIENT -16.683 -0.42 17.312

7997 601 DEAD LOAD -8.54 51.297 2.424

602 LIVE LOAD - BRIDGE WALKWAY -4.874 33.433 1.497

603 FLUID LOADS - OPERATING CONDITION -114.586 594.779 27.978

604 FLUID LOADS - SANDED CONDITION -126.823 658.243 30.965

605 LIVE LOAD - TORQUE AND LIFTING - NORMAL OPERATING -0.731 1.212 0.195

606 LIVE LOAD - TORQUE AND LIFTING - MAXIMUM -2.265 3.738 0.606

607 WIND LOAD - Z DIRECTION 3.196 -2.171 -0.962

608 WIND LOAD - X DIRECTION -15.68 25.023 4.177

609 SEISMIC LOAD - Z POSITIVE DIRECTION 68.301 -72.892 -19.963

610 SEISMIC LOAD - Z NEGATIVE DIRECTION -68.301 72.892 19.963

611 SEISMIC LOAD - X POSITIVE DIRECTION -252.809 443.074 66.783

612 SEISMIC LOAD - X NEGATIVE DIRECTION 252.809 -443.074 -66.783

613 SEISMIC LOAD - Y DIRECTION 0 0 0

614 POSITIVE THERMAL GRADIENT -20.495 -3.851 4.997

615 NEGATIVE THERMAL GRADIENT 20.495 3.851 -4.997

7998 601 DEAD LOAD 8.495 49.987 -2.159

602 LIVE LOAD - BRIDGE WALKWAY 4.93 32.531 -1.144

603 FLUID LOADS - OPERATING CONDITION 111.22 599.111 -32.669

604 FLUID LOADS - SANDED CONDITION 123.1 663.169 -36.159

605 LIVE LOAD - TORQUE AND LIFTING - NORMAL OPERATING -0.726 -1.211 0.196

606 LIVE LOAD - TORQUE AND LIFTING - MAXIMUM -2.226 -3.728 0.6

607 WIND LOAD - Z DIRECTION 1.59 3.978 -0.533

608 WIND LOAD - X DIRECTION -11.028 -20.927 2.975

609 SEISMIC LOAD - Z POSITIVE DIRECTION 81.611 171.601 -23.463

Page 8
Project : OCP Benguerir
Description : Foundation Load (Reactions) Data
Structure : 45m Diameter High Rate Thickeners
Doc. No. : 2689A0TR045VB101 Rev. : A
Client : OCP, Morocco

610 SEISMIC LOAD - Z NEGATIVE DIRECTION -81.611 -171.601 23.463

611 SEISMIC LOAD - X POSITIVE DIRECTION -250.199 -426.299 67.075

612 SEISMIC LOAD - X NEGATIVE DIRECTION 250.199 426.299 -67.075

613 SEISMIC LOAD - Y DIRECTION 0 0 0

614 POSITIVE THERMAL GRADIENT 23.265 0.674 -6.696

615 NEGATIVE THERMAL GRADIENT -23.265 -0.674 6.696

7999 601 DEAD LOAD -8.597 50.426 -2.175

602 LIVE LOAD - BRIDGE WALKWAY -4.959 32.901 -1.142

603 FLUID LOADS - OPERATING CONDITION -113.218 593.975 -33.072

604 FLUID LOADS - SANDED CONDITION -125.309 657.434 -36.604

605 LIVE LOAD - TORQUE AND LIFTING - NORMAL OPERATING -0.73 1.213 -0.196

606 LIVE LOAD - TORQUE AND LIFTING - MAXIMUM -2.265 3.741 -0.608

607 WIND LOAD - Z DIRECTION 0.219 1.542 -0.071

608 WIND LOAD - X DIRECTION -27.113 47.833 -7.218

609 SEISMIC LOAD - Z POSITIVE DIRECTION -66.478 155.324 -19.759

610 SEISMIC LOAD - Z NEGATIVE DIRECTION 66.478 -155.324 19.759

611 SEISMIC LOAD - X POSITIVE DIRECTION -251.548 416.778 -67.429

612 SEISMIC LOAD - X NEGATIVE DIRECTION 251.548 -416.778 67.429

613 SEISMIC LOAD - Y DIRECTION 0 0 0

614 POSITIVE THERMAL GRADIENT -20.164 -3.953 -5.902

615 NEGATIVE THERMAL GRADIENT 20.164 3.953 5.902

8000 601 DEAD LOAD 8.385 50.576 2.368

602 LIVE LOAD - BRIDGE WALKWAY 4.811 32.878 1.469

603 FLUID LOADS - OPERATING CONDITION 112.581 599.635 27.306

604 FLUID LOADS - SANDED CONDITION 124.612 663.693 30.223

605 LIVE LOAD - TORQUE AND LIFTING - NORMAL OPERATING -0.727 -1.211 -0.194

606 LIVE LOAD - TORQUE AND LIFTING - MAXIMUM -2.227 -3.728 -0.593

607 WIND LOAD - Z DIRECTION -1.867 -1.327 -0.595

608 WIND LOAD - X DIRECTION -21.849 -40.057 -5.784

Page 9
Project : OCP Benguerir
Description : Foundation Load (Reactions) Data
Structure : 45m Diameter High Rate Thickeners
Doc. No. : 2689A0TR045VB101 Rev. : A
Client : OCP, Morocco

609 SEISMIC LOAD - Z POSITIVE DIRECTION -52.113 -56.518 -15.286

610 SEISMIC LOAD - Z NEGATIVE DIRECTION 52.113 56.518 15.286

611 SEISMIC LOAD - X POSITIVE DIRECTION -252.7 -435.907 -66.835

612 SEISMIC LOAD - X NEGATIVE DIRECTION 252.7 435.907 66.835

613 SEISMIC LOAD - Y DIRECTION 0 0 0

614 POSITIVE THERMAL GRADIENT 23.533 0.781 5.841

615 NEGATIVE THERMAL GRADIENT -23.533 -0.781 -5.841

8001 601 DEAD LOAD -6.348 50.441 -6.17

602 LIVE LOAD - BRIDGE WALKWAY -3.719 32.92 -3.463

603 FLUID LOADS - OPERATING CONDITION -81.537 593.998 -85.26

604 FLUID LOADS - SANDED CONDITION -90.246 657.458 -94.367

605 LIVE LOAD - TORQUE AND LIFTING - NORMAL OPERATING -0.534 1.213 -0.535

606 LIVE LOAD - TORQUE AND LIFTING - MAXIMUM -1.658 3.741 -1.659

607 WIND LOAD - Z DIRECTION -3.091 8.293 -3.228

608 WIND LOAD - X DIRECTION -15.096 32.925 -15.061

609 SEISMIC LOAD - Z POSITIVE DIRECTION -133.955 343.163 -136.263

610 SEISMIC LOAD - Z NEGATIVE DIRECTION 133.955 -343.163 136.263

611 SEISMIC LOAD - X POSITIVE DIRECTION -134.732 279.549 -133.513

612 SEISMIC LOAD - X NEGATIVE DIRECTION 134.732 -279.549 133.513

613 SEISMIC LOAD - Y DIRECTION 0 0 0

614 POSITIVE THERMAL GRADIENT -14.526 -3.823 -15.213

615 NEGATIVE THERMAL GRADIENT 14.526 3.823 15.213

8002 601 DEAD LOAD 6.099 50.488 6.265

602 LIVE LOAD - BRIDGE WALKWAY 3.443 32.842 3.69

603 FLUID LOADS - OPERATING CONDITION 83.867 599.481 79.965

604 FLUID LOADS - SANDED CONDITION 92.826 663.532 88.507

605 LIVE LOAD - TORQUE AND LIFTING - NORMAL OPERATING -0.533 -1.211 -0.531

606 LIVE LOAD - TORQUE AND LIFTING - MAXIMUM -1.632 -3.729 -1.627

607 WIND LOAD - Z DIRECTION -3.331 -7.596 -3.41

Page 10
Project : OCP Benguerir
Description : Foundation Load (Reactions) Data
Structure : 45m Diameter High Rate Thickeners
Doc. No. : 2689A0TR045VB101 Rev. : A
Client : OCP, Morocco

608 WIND LOAD - X DIRECTION -17.898 -42.06 -17.796

609 SEISMIC LOAD - Z POSITIVE DIRECTION -125.527 -268.9 -126.481

610 SEISMIC LOAD - Z NEGATIVE DIRECTION 125.527 268.9 126.481

611 SEISMIC LOAD - X POSITIVE DIRECTION -142.025 -350.409 -140.147

612 SEISMIC LOAD - X NEGATIVE DIRECTION 142.025 350.409 140.147

613 SEISMIC LOAD - Y DIRECTION 0 0 0

614 POSITIVE THERMAL GRADIENT 17.387 0.668 16.745

615 NEGATIVE THERMAL GRADIENT -17.387 -0.668 -16.745

8003 601 DEAD LOAD -2.417 50.459 -8.534

602 LIVE LOAD - BRIDGE WALKWAY -1.494 32.911 -4.876

603 FLUID LOADS - OPERATING CONDITION -27.976 594.065 -114.594

604 FLUID LOADS - SANDED CONDITION -30.963 657.53 -126.833

605 LIVE LOAD - TORQUE AND LIFTING - NORMAL OPERATING -0.195 1.213 -0.731

606 LIVE LOAD - TORQUE AND LIFTING - MAXIMUM -0.606 3.741 -2.266

607 WIND LOAD - Z DIRECTION -4.225 23.606 -15.929

608 WIND LOAD - X DIRECTION -1.551 8.781 -5.535

609 SEISMIC LOAD - Z POSITIVE DIRECTION -66.78 438.676 -252.91

610 SEISMIC LOAD - Z NEGATIVE DIRECTION 66.78 -438.676 252.91

611 SEISMIC LOAD - X POSITIVE DIRECTION -19.338 72.322 -66.219

612 SEISMIC LOAD - X NEGATIVE DIRECTION 19.338 -72.322 66.219

613 SEISMIC LOAD - Y DIRECTION 0 0 0

614 POSITIVE THERMAL GRADIENT -5.013 -3.465 -20.609

615 NEGATIVE THERMAL GRADIENT 5.013 3.465 20.609

8004 601 DEAD LOAD 2.153 50.514 8.489

602 LIVE LOAD - BRIDGE WALKWAY 1.138 32.857 4.922

603 FLUID LOADS - OPERATING CONDITION 32.653 599.51 111.176

604 FLUID LOADS - SANDED CONDITION 36.142 663.562 123.051

605 LIVE LOAD - TORQUE AND LIFTING - NORMAL OPERATING -0.196 -1.211 -0.726

606 LIVE LOAD - TORQUE AND LIFTING - MAXIMUM -0.6 -3.729 -2.226

Page 11
Project : OCP Benguerir
Description : Foundation Load (Reactions) Data
Structure : 45m Diameter High Rate Thickeners
Doc. No. : 2689A0TR045VB101 Rev. : A
Client : OCP, Morocco

607 WIND LOAD - Z DIRECTION -2.582 -14.275 -9.435

608 WIND LOAD - X DIRECTION -3.295 -20.917 -12.038

609 SEISMIC LOAD - Z POSITIVE DIRECTION -65.933 -409.032 -245.617

610 SEISMIC LOAD - Z NEGATIVE DIRECTION 65.933 409.032 245.617

611 SEISMIC LOAD - X POSITIVE DIRECTION -23.192 -169.503 -80.875

612 SEISMIC LOAD - X NEGATIVE DIRECTION 23.192 169.503 80.875

613 SEISMIC LOAD - Y DIRECTION 0 0 0

614 POSITIVE THERMAL GRADIENT 6.62 0.348 22.935

615 NEGATIVE THERMAL GRADIENT -6.62 -0.348 -22.935

8005 601 DEAD LOAD 2.175 50.466 -8.605

602 LIVE LOAD - BRIDGE WALKWAY 1.143 32.931 -4.969

603 FLUID LOADS - OPERATING CONDITION 33.073 594.023 -113.229

604 FLUID LOADS - SANDED CONDITION 36.605 657.484 -125.32

605 LIVE LOAD - TORQUE AND LIFTING - NORMAL OPERATING 0.196 1.214 -0.731

606 LIVE LOAD - TORQUE AND LIFTING - MAXIMUM 0.608 3.741 -2.265

607 WIND LOAD - Z DIRECTION 7.46 48.223 -28.028

608 WIND LOAD - X DIRECTION -3.13 -20.215 11.362

609 SEISMIC LOAD - Z POSITIVE DIRECTION 67.82 416.617 -253.021

610 SEISMIC LOAD - Z NEGATIVE DIRECTION -67.82 -416.617 253.021

611 SEISMIC LOAD - X POSITIVE DIRECTION -19.895 -155.329 67.32

612 SEISMIC LOAD - X NEGATIVE DIRECTION 19.895 155.329 -67.32

613 SEISMIC LOAD - Y DIRECTION 0 0 0

614 POSITIVE THERMAL GRADIENT 6.033 -2.847 -20.588

615 NEGATIVE THERMAL GRADIENT -6.033 2.847 20.588

8006 601 DEAD LOAD -2.38 50.505 8.427

602 LIVE LOAD - BRIDGE WALKWAY -1.476 32.828 4.836

603 FLUID LOADS - OPERATING CONDITION -27.314 599.562 112.611

604 FLUID LOADS - SANDED CONDITION -30.231 663.619 124.64

605 LIVE LOAD - TORQUE AND LIFTING - NORMAL OPERATING 0.194 -1.211 -0.727

Page 12
Project : OCP Benguerir
Description : Foundation Load (Reactions) Data
Structure : 45m Diameter High Rate Thickeners
Doc. No. : 2689A0TR045VB101 Rev. : A
Client : OCP, Morocco

606 LIVE LOAD - TORQUE AND LIFTING - MAXIMUM 0.593 -3.729 -2.227

607 WIND LOAD - Z DIRECTION 5.921 -41.97 -22.407

608 WIND LOAD - X DIRECTION -1.328 7.974 4.77

609 SEISMIC LOAD - Z POSITIVE DIRECTION 67.039 -439.535 -253.536

610 SEISMIC LOAD - Z NEGATIVE DIRECTION -67.039 439.535 253.536

611 SEISMIC LOAD - X POSITIVE DIRECTION -14.946 56.4 51.089

612 SEISMIC LOAD - X NEGATIVE DIRECTION 14.946 -56.4 -51.089

613 SEISMIC LOAD - Y DIRECTION 0 0 0

614 POSITIVE THERMAL GRADIENT -5.607 -0.487 22.726

615 NEGATIVE THERMAL GRADIENT 5.607 0.487 -22.726

8007 601 DEAD LOAD 6.173 50.433 -6.351

602 LIVE LOAD - BRIDGE WALKWAY 3.467 32.915 -3.724

603 FLUID LOADS - OPERATING CONDITION 85.265 594 -81.542

604 FLUID LOADS - SANDED CONDITION 94.372 657.461 -90.252

605 LIVE LOAD - TORQUE AND LIFTING - NORMAL OPERATING 0.535 1.213 -0.535

606 LIVE LOAD - TORQUE AND LIFTING - MAXIMUM 1.66 3.741 -1.658

607 WIND LOAD - Z DIRECTION 15.959 34.627 -16.041

608 WIND LOAD - X DIRECTION -17.607 -41.62 17.49

609 SEISMIC LOAD - Z POSITIVE DIRECTION 135.182 282.897 -136.49

610 SEISMIC LOAD - Z NEGATIVE DIRECTION -135.182 -282.897 136.49

611 SEISMIC LOAD - X POSITIVE DIRECTION -136.237 -341.721 134.027

612 SEISMIC LOAD - X NEGATIVE DIRECTION 136.237 341.721 -134.027

613 SEISMIC LOAD - Y DIRECTION 0 0 0

614 POSITIVE THERMAL GRADIENT 15.359 -3.154 -14.658

615 NEGATIVE THERMAL GRADIENT -15.359 3.154 14.658

8008 601 DEAD LOAD -6.271 50.493 6.105

602 LIVE LOAD - BRIDGE WALKWAY -3.695 32.844 3.448

603 FLUID LOADS - OPERATING CONDITION -79.966 599.478 83.867

604 FLUID LOADS - SANDED CONDITION -88.508 663.528 92.827

Page 13
Project : OCP Benguerir
Description : Foundation Load (Reactions) Data
Structure : 45m Diameter High Rate Thickeners
Doc. No. : 2689A0TR045VB101 Rev. : A
Client : OCP, Morocco

605 LIVE LOAD - TORQUE AND LIFTING - NORMAL OPERATING 0.531 -1.211 -0.532

606 LIVE LOAD - TORQUE AND LIFTING - MAXIMUM 1.627 -3.729 -1.632

607 WIND LOAD - Z DIRECTION 17.938 -43.132 -18.086

608 WIND LOAD - X DIRECTION -14.599 32.213 14.583

609 SEISMIC LOAD - Z POSITIVE DIRECTION 140.353 -352.235 -142.315

610 SEISMIC LOAD - Z NEGATIVE DIRECTION -140.353 352.235 142.315

611 SEISMIC LOAD - X POSITIVE DIRECTION -125.126 266.119 124.246

612 SEISMIC LOAD - X NEGATIVE DIRECTION 125.126 -266.119 -124.246

613 SEISMIC LOAD - Y DIRECTION 0 0 0

614 POSITIVE THERMAL GRADIENT -15.715 -0.902 16.372

615 NEGATIVE THERMAL GRADIENT 15.715 0.902 -16.372

8009 601 DEAD LOAD 8.488 50.509 -2.405

602 LIVE LOAD - BRIDGE WALKWAY 4.847 32.94 -1.487

603 FLUID LOADS - OPERATING CONDITION 114.571 594.121 -27.97

604 FLUID LOADS - SANDED CONDITION 126.811 657.587 -30.957

605 LIVE LOAD - TORQUE AND LIFTING - NORMAL OPERATING 0.731 1.213 -0.195

606 LIVE LOAD - TORQUE AND LIFTING - MAXIMUM 2.266 3.741 -0.606

607 WIND LOAD - Z DIRECTION 6.406 9.156 -1.828

608 WIND LOAD - X DIRECTION -21.77 -39.98 5.761

609 SEISMIC LOAD - Z POSITIVE DIRECTION 67.905 73.17 -19.869

610 SEISMIC LOAD - Z NEGATIVE DIRECTION -67.905 -73.17 19.869

611 SEISMIC LOAD - X POSITIVE DIRECTION -252.055 -435.079 66.577

612 SEISMIC LOAD - X NEGATIVE DIRECTION 252.055 435.079 -66.577

613 SEISMIC LOAD - Y DIRECTION 0 0 0

614 POSITIVE THERMAL GRADIENT 20.57 -3.461 -4.996

615 NEGATIVE THERMAL GRADIENT -20.57 3.461 4.996

8010 601 DEAD LOAD -8.511 50.511 2.16

602 LIVE LOAD - BRIDGE WALKWAY -4.942 32.859 1.144

603 FLUID LOADS - OPERATING CONDITION -111.182 599.503 32.656

Page 14
Project : OCP Benguerir
Description : Foundation Load (Reactions) Data
Structure : 45m Diameter High Rate Thickeners
Doc. No. : 2689A0TR045VB101 Rev. : A
Client : OCP, Morocco

604 FLUID LOADS - SANDED CONDITION -123.057 663.554 36.144

605 LIVE LOAD - TORQUE AND LIFTING - NORMAL OPERATING 0.726 -1.211 -0.196

606 LIVE LOAD - TORQUE AND LIFTING - MAXIMUM 2.225 -3.728 -0.6

607 WIND LOAD - Z DIRECTION 11.839 -21.085 -3.284

608 WIND LOAD - X DIRECTION -26.708 47.436 7.118

609 SEISMIC LOAD - Z POSITIVE DIRECTION 80.644 -170.185 -23.205

610 SEISMIC LOAD - Z NEGATIVE DIRECTION -80.644 170.185 23.205

611 SEISMIC LOAD - X POSITIVE DIRECTION -244.387 409.518 65.603

612 SEISMIC LOAD - X NEGATIVE DIRECTION 244.387 -409.518 -65.603

613 SEISMIC LOAD - Y DIRECTION 0 0 0

614 POSITIVE THERMAL GRADIENT -22.72 0.123 6.562

615 NEGATIVE THERMAL GRADIENT 22.72 -0.123 -6.562

8011 601 DEAD LOAD 8.582 49.865 2.174

602 LIVE LOAD - BRIDGE WALKWAY 4.954 32.533 1.142

603 FLUID LOADS - OPERATING CONDITION 113.239 593.601 33.079

604 FLUID LOADS - SANDED CONDITION 125.334 657.072 36.613

605 LIVE LOAD - TORQUE AND LIFTING - NORMAL OPERATING 0.731 1.213 0.196

606 LIVE LOAD - TORQUE AND LIFTING - MAXIMUM 2.266 3.741 0.608

607 WIND LOAD - Z DIRECTION -11.823 -21.583 -3.302

608 WIND LOAD - X DIRECTION -11.271 -21.01 -3.034

609 SEISMIC LOAD - Z POSITIVE DIRECTION -67.442 -156.726 -20.016

610 SEISMIC LOAD - Z NEGATIVE DIRECTION 67.442 156.726 20.016

611 SEISMIC LOAD - X POSITIVE DIRECTION -257.281 -433.185 -68.875

612 SEISMIC LOAD - X NEGATIVE DIRECTION 257.281 433.185 68.875

613 SEISMIC LOAD - Y DIRECTION 0 0 0

614 POSITIVE THERMAL GRADIENT 20.496 -3.229 6

615 NEGATIVE THERMAL GRADIENT -20.496 3.229 -6

8012 601 DEAD LOAD -8.466 51.368 -2.396

602 LIVE LOAD - BRIDGE WALKWAY -4.867 33.398 -1.488

Page 15
Project : OCP Benguerir
Description : Foundation Load (Reactions) Data
Structure : 45m Diameter High Rate Thickeners
Doc. No. : 2689A0TR045VB101 Rev. : A
Client : OCP, Morocco

603 FLUID LOADS - OPERATING CONDITION -112.614 600.136 -27.318

604 FLUID LOADS - SANDED CONDITION -124.641 664.175 -30.235

605 LIVE LOAD - TORQUE AND LIFTING - NORMAL OPERATING 0.727 -1.21 0.194

606 LIVE LOAD - TORQUE AND LIFTING - MAXIMUM 2.227 -3.726 0.593

607 WIND LOAD - Z DIRECTION -5.69 7.811 -1.6

608 WIND LOAD - X DIRECTION -15.599 24.585 -4.154

609 SEISMIC LOAD - Z POSITIVE DIRECTION -52.508 56.245 -15.381

610 SEISMIC LOAD - Z NEGATIVE DIRECTION 52.508 -56.245 15.381

611 SEISMIC LOAD - X POSITIVE DIRECTION -253.268 442.827 -66.988

612 SEISMIC LOAD - X NEGATIVE DIRECTION 253.268 -442.827 66.988

613 SEISMIC LOAD - Y DIRECTION 0 0 0

614 POSITIVE THERMAL GRADIENT -23.058 0.053 -5.71

615 NEGATIVE THERMAL GRADIENT 23.058 -0.053 5.71

8013 601 DEAD LOAD 5.086 50.092 4.892

602 LIVE LOAD - BRIDGE WALKWAY 2.897 32.688 2.629

603 FLUID LOADS - OPERATING CONDITION 80.722 594.088 84.431

604 FLUID LOADS - SANDED CONDITION 89.46 657.59 93.566

605 LIVE LOAD - TORQUE AND LIFTING - NORMAL OPERATING 0.534 1.213 0.535

606 LIVE LOAD - TORQUE AND LIFTING - MAXIMUM 1.657 3.739 1.658

607 WIND LOAD - Z DIRECTION -18.274 -42.865 -18.461

608 WIND LOAD - X DIRECTION -13.333 -1.744 -13.511

609 SEISMIC LOAD - Z POSITIVE DIRECTION -134.46 -343.561 -136.78

610 SEISMIC LOAD - Z NEGATIVE DIRECTION 134.46 343.561 136.78

611 SEISMIC LOAD - X POSITIVE DIRECTION -159.822 -267.347 -159.17

612 SEISMIC LOAD - X NEGATIVE DIRECTION 159.822 267.347 159.17

613 SEISMIC LOAD - Y DIRECTION 0 0 0

614 POSITIVE THERMAL GRADIENT 14.886 -3.085 15.571

615 NEGATIVE THERMAL GRADIENT -14.886 3.085 -15.571

8014 601 DEAD LOAD -6.346 45.894 -6.451

Page 16
Project : OCP Benguerir
Description : Foundation Load (Reactions) Data
Structure : 45m Diameter High Rate Thickeners
Doc. No. : 2689A0TR045VB101 Rev. : A
Client : OCP, Morocco

602 LIVE LOAD - BRIDGE WALKWAY -3.608 29.852 -3.816

603 FLUID LOADS - OPERATING CONDITION -84.007 595.993 -80.061

604 FLUID LOADS - SANDED CONDITION -92.959 660.096 -88.598

605 LIVE LOAD - TORQUE AND LIFTING - NORMAL OPERATING 0.532 -1.214 0.531

606 LIVE LOAD - TORQUE AND LIFTING - MAXIMUM 1.632 -3.737 1.627

607 WIND LOAD - Z DIRECTION -16.291 39.247 -16.372

608 WIND LOAD - X DIRECTION -7.979 -9.95 -7.548

609 SEISMIC LOAD - Z POSITIVE DIRECTION -126.47 275.396 -127.464

610 SEISMIC LOAD - Z NEGATIVE DIRECTION 126.47 -275.396 127.464

611 SEISMIC LOAD - X POSITIVE DIRECTION -153.289 307.64 -150.541

612 SEISMIC LOAD - X NEGATIVE DIRECTION 153.289 -307.64 150.541

613 SEISMIC LOAD - Y DIRECTION 0 0 0

614 POSITIVE THERMAL GRADIENT -17.101 0.036 -16.468

615 NEGATIVE THERMAL GRADIENT 17.101 -0.036 16.468

8015 601 DEAD LOAD 4.721 59.417 17.082

602 LIVE LOAD - BRIDGE WALKWAY 2.983 38.648 10.402

603 FLUID LOADS - OPERATING CONDITION 29.945 602.151 121.898

604 FLUID LOADS - SANDED CONDITION 32.93 665.649 134.129

605 LIVE LOAD - TORQUE AND LIFTING - NORMAL OPERATING 0.196 1.222 0.735

606 LIVE LOAD - TORQUE AND LIFTING - MAXIMUM 0.609 3.768 2.279

607 WIND LOAD - Z DIRECTION -9.237 -72.156 -34.328

608 WIND LOAD - X DIRECTION -0.658 -114.556 0.716

609 SEISMIC LOAD - Z POSITIVE DIRECTION -70.172 -466.797 -265.155

610 SEISMIC LOAD - Z NEGATIVE DIRECTION 70.172 466.797 265.155

611 SEISMIC LOAD - X POSITIVE DIRECTION -19.869 -350.425 -61.056

612 SEISMIC LOAD - X NEGATIVE DIRECTION 19.869 350.425 61.056

613 SEISMIC LOAD - Y DIRECTION 0 0 0

614 POSITIVE THERMAL GRADIENT 5.093 -3.23 20.864

615 NEGATIVE THERMAL GRADIENT -5.093 3.23 -20.864

Page 17
Project : OCP Benguerir
Description : Foundation Load (Reactions) Data
Structure : 45m Diameter High Rate Thickeners
Doc. No. : 2689A0TR045VB101 Rev. : A
Client : OCP, Morocco

8016 601 DEAD LOAD -2.358 100.851 -10.644

602 LIVE LOAD - BRIDGE WALKWAY -1.273 65.341 -6.322

603 FLUID LOADS - OPERATING CONDITION -32.739 641.001 -112.65

604 FLUID LOADS - SANDED CONDITION -36.218 704.843 -124.484

605 LIVE LOAD - TORQUE AND LIFTING - NORMAL OPERATING 0.196 -1.2 0.726

606 LIVE LOAD - TORQUE AND LIFTING - MAXIMUM 0.6 -3.694 2.224

607 WIND LOAD - Z DIRECTION -7.914 30.272 -28.959

608 WIND LOAD - X DIRECTION -2.195 136.193 -11.3

609 SEISMIC LOAD - Z POSITIVE DIRECTION -66.481 390.528 -246.909

610 SEISMIC LOAD - Z NEGATIVE DIRECTION 66.481 -390.528 246.909

611 SEISMIC LOAD - X POSITIVE DIRECTION -27.862 491.103 -106.343

612 SEISMIC LOAD - X NEGATIVE DIRECTION 27.862 -491.103 106.343

613 SEISMIC LOAD - Y DIRECTION 0 0 0

614 POSITIVE THERMAL GRADIENT -6.58 -0.215 -22.832

615 NEGATIVE THERMAL GRADIENT 6.58 0.215 22.832

Page 18
Project : OCP Benguerir
Description : Foundation Load (Reactions) Data
Structure : 45m Diameter High Rate Thickeners
Doc. No. : 2689A0TR045VB101 Rev. : A
Client : OCP, Morocco

1.3 Support Reactions – Columns-PCD2

Page 19
Project : OCP Benguerir
Description : Foundation Load (Reactions) Data
Structure : 45m Diameter High Rate Thickeners
Doc. No. : 2689A0TR045VB101 Rev. : A
Client : OCP, Morocco

Horizontal Vertical Horizontal

Node L/C Fx kN Fy kN Fz kN

12781 601 DEAD LOAD 0.325 12.308 0.036

602 LIVE LOAD - BRIDGE WALKWAY 0.337 -6.682 0.041

603 FLUID LOADS - OPERATING CONDITION 53.882 683.762 6.918

604 FLUID LOADS - SANDED CONDITION 59.612 757.395 7.653

605 LIVE LOAD - TORQUE AND LIFTING - NORMAL OPERATING -0.065 0.13 -0.008

606 LIVE LOAD - TORQUE AND LIFTING - MAXIMUM -0.077 0.169 -0.007

607 WIND LOAD - Z DIRECTION 0.498 -4.242 0.036

608 WIND LOAD - X DIRECTION -10.522 4.878 -1.383

609 SEISMIC LOAD - Z POSITIVE DIRECTION -1.209 7.688 0.383

610 SEISMIC LOAD - Z NEGATIVE DIRECTION 1.209 -7.688 -0.383

611 SEISMIC LOAD - X POSITIVE DIRECTION -298.762 537.168 -39.322

612 SEISMIC LOAD - X NEGATIVE DIRECTION 298.762 -537.168 39.322

613 SEISMIC LOAD - Y DIRECTION 0 0 0

614 POSITIVE THERMAL GRADIENT -39.694 45.195 -5.238

615 NEGATIVE THERMAL GRADIENT 39.694 -45.195 5.238

12782 601 DEAD LOAD 0.043 22.367 0.022

602 LIVE LOAD - BRIDGE WALKWAY -0.011 -3.028 -0.003

603 FLUID LOADS - OPERATING CONDITION 2.616 1032.943 1.228

604 FLUID LOADS - SANDED CONDITION 2.896 1143.345 1.36

605 LIVE LOAD - TORQUE AND LIFTING - NORMAL OPERATING -0.001 -0.087 0.001

606 LIVE LOAD - TORQUE AND LIFTING - MAXIMUM -0.001 -0.27 0.003

607 WIND LOAD - Z DIRECTION -0.068 -0.525 -0.046

608 WIND LOAD - X DIRECTION -0.035 10.166 -0.017

609 SEISMIC LOAD - Z POSITIVE DIRECTION -1.286 38.488 -0.049

610 SEISMIC LOAD - Z NEGATIVE DIRECTION 1.286 -38.488 0.049

611 SEISMIC LOAD - X POSITIVE DIRECTION -2.315 30.605 -1.219

612 SEISMIC LOAD - X NEGATIVE DIRECTION 2.315 -30.605 1.219

Page 20
Project : OCP Benguerir
Description : Foundation Load (Reactions) Data
Structure : 45m Diameter High Rate Thickeners
Doc. No. : 2689A0TR045VB101 Rev. : A
Client : OCP, Morocco

613 SEISMIC LOAD - Y DIRECTION 0 0 0

614 POSITIVE THERMAL GRADIENT -0.297 -0.265 -0.105

615 NEGATIVE THERMAL GRADIENT 0.297 0.265 0.105

12783 601 DEAD LOAD 0.192 18.939 0.142

602 LIVE LOAD - BRIDGE WALKWAY 0.221 -2.419 0.168

603 FLUID LOADS - OPERATING CONDITION 43.145 689.498 32.899

604 FLUID LOADS - SANDED CONDITION 47.739 763.133 36.402

605 LIVE LOAD - TORQUE AND LIFTING - NORMAL OPERATING -0.053 0.13 -0.039

606 LIVE LOAD - TORQUE AND LIFTING - MAXIMUM -0.064 0.166 -0.045

607 WIND LOAD - Z DIRECTION -7.417 17.793 -5.699

608 WIND LOAD - X DIRECTION -8.541 24.065 -6.527

609 SEISMIC LOAD - Z POSITIVE DIRECTION -126.082 308.551 -96.143

610 SEISMIC LOAD - Z NEGATIVE DIRECTION 126.082 -308.551 96.143

611 SEISMIC LOAD - X POSITIVE DIRECTION -210.272 510.2 -161.62

612 SEISMIC LOAD - X NEGATIVE DIRECTION 210.272 -510.2 161.62

613 SEISMIC LOAD - Y DIRECTION 0 0 0

614 POSITIVE THERMAL GRADIENT -31.659 45.021 -24.308

615 NEGATIVE THERMAL GRADIENT 31.659 -45.021 24.308

12784 601 DEAD LOAD 0.025 22.669 0.041

602 LIVE LOAD - BRIDGE WALKWAY -0.008 -2.834 -0.007

603 FLUID LOADS - OPERATING CONDITION 1.655 1033.29 2.37

604 FLUID LOADS - SANDED CONDITION 1.832 1143.7 2.624

605 LIVE LOAD - TORQUE AND LIFTING - NORMAL OPERATING -0.001 -0.087 0

606 LIVE LOAD - TORQUE AND LIFTING - MAXIMUM -0.002 -0.272 0.002

607 WIND LOAD - Z DIRECTION -0.081 0.961 -0.121

608 WIND LOAD - X DIRECTION -0.064 -3.742 -0.063

609 SEISMIC LOAD - Z POSITIVE DIRECTION -1.723 37.362 -1.799

610 SEISMIC LOAD - Z NEGATIVE DIRECTION 1.723 -37.362 1.799

611 SEISMIC LOAD - X POSITIVE DIRECTION -0.814 -22.844 -1.738

Page 21
Project : OCP Benguerir
Description : Foundation Load (Reactions) Data
Structure : 45m Diameter High Rate Thickeners
Doc. No. : 2689A0TR045VB101 Rev. : A
Client : OCP, Morocco

612 SEISMIC LOAD - X NEGATIVE DIRECTION 0.814 22.844 1.738

613 SEISMIC LOAD - Y DIRECTION 0 0 0

614 POSITIVE THERMAL GRADIENT -0.204 -0.242 -0.24

615 NEGATIVE THERMAL GRADIENT 0.204 0.242 0.24

12785 601 DEAD LOAD 0.091 18.17 0.207

602 LIVE LOAD - BRIDGE WALKWAY 0.104 -2.899 0.246

603 FLUID LOADS - OPERATING CONDITION 20.91 688.845 50.034

604 FLUID LOADS - SANDED CONDITION 23.137 762.479 55.364

605 LIVE LOAD - TORQUE AND LIFTING - NORMAL OPERATING -0.026 0.131 -0.061

606 LIVE LOAD - TORQUE AND LIFTING - MAXIMUM -0.033 0.168 -0.072

607 WIND LOAD - Z DIRECTION -6.113 29.355 -14.755

608 WIND LOAD - X DIRECTION -2.137 9.867 -5.126

609 SEISMIC LOAD - Z POSITIVE DIRECTION -104.878 522.466 -252.44

610 SEISMIC LOAD - Z NEGATIVE DIRECTION 104.878 -522.466 252.44

611 SEISMIC LOAD - X POSITIVE DIRECTION -57.648 280.938 -140.372

612 SEISMIC LOAD - X NEGATIVE DIRECTION 57.648 -280.938 140.372

613 SEISMIC LOAD - Y DIRECTION 0 0 0

614 POSITIVE THERMAL GRADIENT -15.311 45.258 -36.997

615 NEGATIVE THERMAL GRADIENT 15.311 -45.258 36.997

12786 601 DEAD LOAD 0.002 22.891 0.049

602 LIVE LOAD - BRIDGE WALKWAY -0.003 -2.694 -0.01

603 FLUID LOADS - OPERATING CONDITION 0.238 1033.464 2.883

604 FLUID LOADS - SANDED CONDITION 0.264 1143.873 3.19

605 LIVE LOAD - TORQUE AND LIFTING - NORMAL OPERATING -0.001 -0.087 0

606 LIVE LOAD - TORQUE AND LIFTING - MAXIMUM -0.003 -0.272 0.001

607 WIND LOAD - Z DIRECTION -0.019 0.314 -0.181

608 WIND LOAD - X DIRECTION -0.028 -1.973 -0.02

609 SEISMIC LOAD - Z POSITIVE DIRECTION -0.426 24.386 -3.063

610 SEISMIC LOAD - Z NEGATIVE DIRECTION 0.426 -24.386 3.063

Page 22
Project : OCP Benguerir
Description : Foundation Load (Reactions) Data
Structure : 45m Diameter High Rate Thickeners
Doc. No. : 2689A0TR045VB101 Rev. : A
Client : OCP, Morocco

611 SEISMIC LOAD - X POSITIVE DIRECTION 0.454 -30.46 -0.451

612 SEISMIC LOAD - X NEGATIVE DIRECTION -0.454 30.46 0.451

613 SEISMIC LOAD - Y DIRECTION 0 0 0

614 POSITIVE THERMAL GRADIENT -0.057 -0.215 -0.313

615 NEGATIVE THERMAL GRADIENT 0.057 0.215 0.313

12787 601 DEAD LOAD -0.02 18.325 0.192

602 LIVE LOAD - BRIDGE WALKWAY -0.03 -2.803 0.244

603 FLUID LOADS - OPERATING CONDITION -6.902 689.013 53.748

604 FLUID LOADS - SANDED CONDITION -7.637 762.651 59.477

605 LIVE LOAD - TORQUE AND LIFTING - NORMAL OPERATING 0.008 0.131 -0.066

606 LIVE LOAD - TORQUE AND LIFTING - MAXIMUM 0.007 0.167 -0.078

607 WIND LOAD - Z DIRECTION 2.335 32.93 -17.781

608 WIND LOAD - X DIRECTION 0.013 0.397 -0.637

609 SEISMIC LOAD - Z POSITIVE DIRECTION 41.072 596.958 -312.118

610 SEISMIC LOAD - Z NEGATIVE DIRECTION -41.072 -596.958 312.118

611 SEISMIC LOAD - X POSITIVE DIRECTION 0.533 -8.543 0.099

612 SEISMIC LOAD - X NEGATIVE DIRECTION -0.533 8.543 -0.099

613 SEISMIC LOAD - Y DIRECTION 0 0 0

614 POSITIVE THERMAL GRADIENT 5.29 45.994 -40.082

615 NEGATIVE THERMAL GRADIENT -5.29 -45.994 40.082

12788 601 DEAD LOAD -0.023 22.823 0.043

602 LIVE LOAD - BRIDGE WALKWAY 0.002 -2.734 -0.01

603 FLUID LOADS - OPERATING CONDITION -1.23 1033.389 2.617

604 FLUID LOADS - SANDED CONDITION -1.361 1143.796 2.897

605 LIVE LOAD - TORQUE AND LIFTING - NORMAL OPERATING -0.001 -0.087 -0.001

606 LIVE LOAD - TORQUE AND LIFTING - MAXIMUM -0.003 -0.272 -0.001

607 WIND LOAD - Z DIRECTION 0.063 -0.201 -0.155

608 WIND LOAD - X DIRECTION -0.09 -4.041 0.014

609 SEISMIC LOAD - Z POSITIVE DIRECTION 1.317 5.064 -2.57

Page 23
Project : OCP Benguerir
Description : Foundation Load (Reactions) Data
Structure : 45m Diameter High Rate Thickeners
Doc. No. : 2689A0TR045VB101 Rev. : A
Client : OCP, Morocco

610 SEISMIC LOAD - Z NEGATIVE DIRECTION -1.317 -5.064 2.57

611 SEISMIC LOAD - X POSITIVE DIRECTION -0.018 -39.773 1.229

612 SEISMIC LOAD - X NEGATIVE DIRECTION 0.018 39.773 -1.229

613 SEISMIC LOAD - Y DIRECTION 0 0 0

614 POSITIVE THERMAL GRADIENT 0.109 -0.202 -0.305

615 NEGATIVE THERMAL GRADIENT -0.109 0.202 0.305

12789 601 DEAD LOAD -0.143 18.226 0.195

602 LIVE LOAD - BRIDGE WALKWAY -0.167 -2.868 0.221

603 FLUID LOADS - OPERATING CONDITION -32.884 688.935 43.127

604 FLUID LOADS - SANDED CONDITION -36.386 762.574 47.72

605 LIVE LOAD - TORQUE AND LIFTING - NORMAL OPERATING 0.039 0.13 -0.053

606 LIVE LOAD - TORQUE AND LIFTING - MAXIMUM 0.045 0.167 -0.064

607 WIND LOAD - Z DIRECTION 9.118 27.211 -11.9

608 WIND LOAD - X DIRECTION -4.078 -12.775 5.206

609 SEISMIC LOAD - Z POSITIVE DIRECTION 165.675 511.126 -215.507

610 SEISMIC LOAD - Z NEGATIVE DIRECTION -165.675 -511.126 215.507

611 SEISMIC LOAD - X POSITIVE DIRECTION -91.976 -295.105 120.655

612 SEISMIC LOAD - X NEGATIVE DIRECTION 91.976 295.105 -120.655

613 SEISMIC LOAD - Y DIRECTION 0 0 0

614 POSITIVE THERMAL GRADIENT 25.017 47.202 -32.583

615 NEGATIVE THERMAL GRADIENT -25.017 -47.202 32.583

12790 601 DEAD LOAD -0.042 22.838 0.027

602 LIVE LOAD - BRIDGE WALKWAY 0.006 -2.728 -0.007

603 FLUID LOADS - OPERATING CONDITION -2.371 1033.425 1.656

604 FLUID LOADS - SANDED CONDITION -2.624 1143.834 1.833

605 LIVE LOAD - TORQUE AND LIFTING - NORMAL OPERATING 0 -0.087 -0.001

606 LIVE LOAD - TORQUE AND LIFTING - MAXIMUM -0.002 -0.272 -0.002

607 WIND LOAD - Z DIRECTION 0.081 -0.802 -0.071

608 WIND LOAD - X DIRECTION -0.125 -3.533 0.027

Page 24
Project : OCP Benguerir
Description : Foundation Load (Reactions) Data
Structure : 45m Diameter High Rate Thickeners
Doc. No. : 2689A0TR045VB101 Rev. : A
Client : OCP, Morocco

609 SEISMIC LOAD - Z POSITIVE DIRECTION 1.761 -15.574 -0.814

610 SEISMIC LOAD - Z NEGATIVE DIRECTION -1.761 15.574 0.814

611 SEISMIC LOAD - X POSITIVE DIRECTION -1.717 -36.741 1.666

612 SEISMIC LOAD - X NEGATIVE DIRECTION 1.717 36.741 -1.666

613 SEISMIC LOAD - Y DIRECTION 0 0 0

614 POSITIVE THERMAL GRADIENT 0.253 -0.203 -0.214

615 NEGATIVE THERMAL GRADIENT -0.253 0.203 0.214

12791 601 DEAD LOAD -0.295 18.079 0.128

602 LIVE LOAD - BRIDGE WALKWAY -0.306 -2.965 0.129

603 FLUID LOADS - OPERATING CONDITION -50.103 688.784 20.938

604 FLUID LOADS - SANDED CONDITION -55.431 762.422 23.165

605 LIVE LOAD - TORQUE AND LIFTING - NORMAL OPERATING 0.06 0.129 -0.026

606 LIVE LOAD - TORQUE AND LIFTING - MAXIMUM 0.071 0.166 -0.033

607 WIND LOAD - Z DIRECTION 7.472 14.325 -3.11

608 WIND LOAD - X DIRECTION -11.709 -24.507 4.818

609 SEISMIC LOAD - Z POSITIVE DIRECTION 144.257 288.274 -59.259

610 SEISMIC LOAD - Z NEGATIVE DIRECTION -144.257 -288.274 59.259

611 SEISMIC LOAD - X POSITIVE DIRECTION -242.447 -502.624 100.737

612 SEISMIC LOAD - X NEGATIVE DIRECTION 242.447 502.624 -100.737

613 SEISMIC LOAD - Y DIRECTION 0 0 0

614 POSITIVE THERMAL GRADIENT 38.731 48.753 -16.03

615 NEGATIVE THERMAL GRADIENT -38.731 -48.753 16.03

12792 601 DEAD LOAD -0.05 22.836 0.002

602 LIVE LOAD - BRIDGE WALKWAY 0.009 -2.73 -0.003

603 FLUID LOADS - OPERATING CONDITION -2.884 1033.416 0.239

604 FLUID LOADS - SANDED CONDITION -3.191 1143.825 0.264

605 LIVE LOAD - TORQUE AND LIFTING - NORMAL OPERATING 0 -0.087 -0.001

606 LIVE LOAD - TORQUE AND LIFTING - MAXIMUM -0.001 -0.272 -0.003

607 WIND LOAD - Z DIRECTION 0.027 -2.676 -0.031

Page 25
Project : OCP Benguerir
Description : Foundation Load (Reactions) Data
Structure : 45m Diameter High Rate Thickeners
Doc. No. : 2689A0TR045VB101 Rev. : A
Client : OCP, Morocco

608 WIND LOAD - X DIRECTION -0.156 -1.971 0.007

609 SEISMIC LOAD - Z POSITIVE DIRECTION 0.462 -32.048 0.449

610 SEISMIC LOAD - Z NEGATIVE DIRECTION -0.462 32.048 -0.449

611 SEISMIC LOAD - X POSITIVE DIRECTION -2.941 -24.144 0.413

612 SEISMIC LOAD - X NEGATIVE DIRECTION 2.941 24.144 -0.413

613 SEISMIC LOAD - Y DIRECTION 0 0 0

614 POSITIVE THERMAL GRADIENT 0.336 -0.229 -0.06

615 NEGATIVE THERMAL GRADIENT -0.336 0.229 0.06

12793 601 DEAD LOAD -0.37 17.99 -0.044

602 LIVE LOAD - BRIDGE WALKWAY -0.37 -3.042 -0.047

603 FLUID LOADS - OPERATING CONDITION -53.901 688.727 -6.922

604 FLUID LOADS - SANDED CONDITION -59.629 762.366 -7.657

605 LIVE LOAD - TORQUE AND LIFTING - NORMAL OPERATING 0.065 0.128 0.007

606 LIVE LOAD - TORQUE AND LIFTING - MAXIMUM 0.076 0.163 0.007

607 WIND LOAD - Z DIRECTION -0.182 -1.265 -0.096

608 WIND LOAD - X DIRECTION -15.324 -29.866 -2.001

609 SEISMIC LOAD - Z POSITIVE DIRECTION -1.786 -11.878 0.31

610 SEISMIC LOAD - Z NEGATIVE DIRECTION 1.786 11.878 -0.31

611 SEISMIC LOAD - X POSITIVE DIRECTION -300.163 -574.775 -39.502

612 SEISMIC LOAD - X NEGATIVE DIRECTION 300.163 574.775 39.502

613 SEISMIC LOAD - Y DIRECTION 0 0 0

614 POSITIVE THERMAL GRADIENT 42.486 50.475 5.605

615 NEGATIVE THERMAL GRADIENT -42.486 -50.475 -5.605

12794 601 DEAD LOAD -0.045 22.836 -0.023

602 LIVE LOAD - BRIDGE WALKWAY 0.009 -2.726 0.001

603 FLUID LOADS - OPERATING CONDITION -2.618 1033.401 -1.23

604 FLUID LOADS - SANDED CONDITION -2.898 1143.808 -1.361

605 LIVE LOAD - TORQUE AND LIFTING - NORMAL OPERATING 0.001 -0.087 -0.001

606 LIVE LOAD - TORQUE AND LIFTING - MAXIMUM 0.001 -0.272 -0.003

Page 26
Project : OCP Benguerir
Description : Foundation Load (Reactions) Data
Structure : 45m Diameter High Rate Thickeners
Doc. No. : 2689A0TR045VB101 Rev. : A
Client : OCP, Morocco

607 WIND LOAD - Z DIRECTION -0.042 -4.165 -0.105

608 WIND LOAD - X DIRECTION -0.152 0.068 -0.029

609 SEISMIC LOAD - Z POSITIVE DIRECTION -1.282 -39.933 -0.045

610 SEISMIC LOAD - Z NEGATIVE DIRECTION 1.282 39.933 0.045

611 SEISMIC LOAD - X POSITIVE DIRECTION -2.465 -5.098 -1.273

612 SEISMIC LOAD - X NEGATIVE DIRECTION 2.465 5.098 1.273

613 SEISMIC LOAD - Y DIRECTION 0 0 0

614 POSITIVE THERMAL GRADIENT 0.334 -0.094 0.119

615 NEGATIVE THERMAL GRADIENT -0.334 0.094 -0.119

12795 601 DEAD LOAD -0.293 18.006 -0.219

602 LIVE LOAD - BRIDGE WALKWAY -0.306 -3.06 -0.232

603 FLUID LOADS - OPERATING CONDITION -43.202 688.769 -32.942

604 FLUID LOADS - SANDED CONDITION -47.794 762.409 -36.443

605 LIVE LOAD - TORQUE AND LIFTING - NORMAL OPERATING 0.052 0.127 0.038

606 LIVE LOAD - TORQUE AND LIFTING - MAXIMUM 0.061 0.159 0.043

607 WIND LOAD - Z DIRECTION -8.38 -20.351 -6.513

608 WIND LOAD - X DIRECTION -11.146 -27.124 -8.48

609 SEISMIC LOAD - Z POSITIVE DIRECTION -126.395 -308.83 -96.381

610 SEISMIC LOAD - Z NEGATIVE DIRECTION 126.395 308.83 96.381

611 SEISMIC LOAD - X POSITIVE DIRECTION -207.347 -492.399 -159.421

612 SEISMIC LOAD - X NEGATIVE DIRECTION 207.347 492.399 159.421

613 SEISMIC LOAD - Y DIRECTION 0 0 0

614 POSITIVE THERMAL GRADIENT -3.19 3.275 -2.429

615 NEGATIVE THERMAL GRADIENT 3.19 -3.275 2.429

12796 601 DEAD LOAD -0.027 22.841 -0.042

602 LIVE LOAD - BRIDGE WALKWAY 0.007 -2.727 0.006

603 FLUID LOADS - OPERATING CONDITION -1.656 1033.426 -2.371

604 FLUID LOADS - SANDED CONDITION -1.833 1143.836 -2.624

605 LIVE LOAD - TORQUE AND LIFTING - NORMAL OPERATING 0.001 -0.087 0

Page 27
Project : OCP Benguerir
Description : Foundation Load (Reactions) Data
Structure : 45m Diameter High Rate Thickeners
Doc. No. : 2689A0TR045VB101 Rev. : A
Client : OCP, Morocco

606 LIVE LOAD - TORQUE AND LIFTING - MAXIMUM 0.002 -0.272 -0.003

607 WIND LOAD - Z DIRECTION -0.06 -3.724 -0.172

608 WIND LOAD - X DIRECTION -0.118 2.025 -0.044

609 SEISMIC LOAD - Z POSITIVE DIRECTION -1.725 -37.104 -1.801

610 SEISMIC LOAD - Z NEGATIVE DIRECTION 1.725 37.104 1.801

611 SEISMIC LOAD - X POSITIVE DIRECTION -0.766 15.53 -1.702

612 SEISMIC LOAD - X NEGATIVE DIRECTION 0.766 -15.53 1.702

613 SEISMIC LOAD - Y DIRECTION 0 0 0

614 POSITIVE THERMAL GRADIENT 0.224 -0.258 0.267

615 NEGATIVE THERMAL GRADIENT -0.224 0.258 -0.267

12797 601 DEAD LOAD -0.13 18.057 -0.302

602 LIVE LOAD - BRIDGE WALKWAY -0.145 -3.05 -0.345

603 FLUID LOADS - OPERATING CONDITION -20.93 688.816 -50.084

604 FLUID LOADS - SANDED CONDITION -23.157 762.453 -55.412

605 LIVE LOAD - TORQUE AND LIFTING - NORMAL OPERATING 0.025 0.126 0.059

606 LIVE LOAD - TORQUE AND LIFTING - MAXIMUM 0.03 0.155 0.065

607 WIND LOAD - Z DIRECTION -7.176 -35.895 -17.397

608 WIND LOAD - X DIRECTION -3.37 -16.901 -7.929

609 SEISMIC LOAD - Z POSITIVE DIRECTION -104.952 -522.984 -252.617

610 SEISMIC LOAD - Z NEGATIVE DIRECTION 104.952 522.984 252.617

611 SEISMIC LOAD - X POSITIVE DIRECTION -57 -277.95 -138.815

612 SEISMIC LOAD - X NEGATIVE DIRECTION 57 277.95 138.815

613 SEISMIC LOAD - Y DIRECTION 0 0 0

614 POSITIVE THERMAL GRADIENT 16.389 50.399 39.596

615 NEGATIVE THERMAL GRADIENT -16.389 -50.399 -39.596

12798 601 DEAD LOAD -0.002 22.848 -0.05

602 LIVE LOAD - BRIDGE WALKWAY 0.003 -2.722 0.009

603 FLUID LOADS - OPERATING CONDITION -0.239 1033.422 -2.883

604 FLUID LOADS - SANDED CONDITION -0.264 1143.831 -3.191

Page 28
Project : OCP Benguerir
Description : Foundation Load (Reactions) Data
Structure : 45m Diameter High Rate Thickeners
Doc. No. : 2689A0TR045VB101 Rev. : A
Client : OCP, Morocco

605 LIVE LOAD - TORQUE AND LIFTING - NORMAL OPERATING 0.001 -0.087 0

606 LIVE LOAD - TORQUE AND LIFTING - MAXIMUM 0.003 -0.272 -0.001

607 WIND LOAD - Z DIRECTION -0.015 -2.089 -0.224

608 WIND LOAD - X DIRECTION -0.073 1.761 -0.01

609 SEISMIC LOAD - Z POSITIVE DIRECTION -0.426 -24.358 -3.063

610 SEISMIC LOAD - Z NEGATIVE DIRECTION 0.426 24.358 3.063

611 SEISMIC LOAD - X POSITIVE DIRECTION 0.455 31.585 -0.442

612 SEISMIC LOAD - X NEGATIVE DIRECTION -0.455 -31.585 0.442

613 SEISMIC LOAD - Y DIRECTION 0 0 0

614 POSITIVE THERMAL GRADIENT 0.061 -0.267 0.332

615 NEGATIVE THERMAL GRADIENT -0.061 0.267 -0.332

12799 601 DEAD LOAD 0.037 18.131 -0.323

602 LIVE LOAD - BRIDGE WALKWAY 0.047 -3.011 -0.373

603 FLUID LOADS - OPERATING CONDITION 6.913 688.892 -53.833

604 FLUID LOADS - SANDED CONDITION 7.648 762.529 -59.562

605 LIVE LOAD - TORQUE AND LIFTING - NORMAL OPERATING -0.007 0.126 0.064

606 LIVE LOAD - TORQUE AND LIFTING - MAXIMUM -0.006 0.153 0.071

607 WIND LOAD - Z DIRECTION 2.878 -42.226 -22

608 WIND LOAD - X DIRECTION -0.005 -0.272 -0.145

609 SEISMIC LOAD - Z POSITIVE DIRECTION 41.072 -596.946 -312.122

610 SEISMIC LOAD - Z NEGATIVE DIRECTION -41.072 596.946 312.122

611 SEISMIC LOAD - X POSITIVE DIRECTION 0.343 12.39 1.55

612 SEISMIC LOAD - X NEGATIVE DIRECTION -0.343 -12.39 -1.55

613 SEISMIC LOAD - Y DIRECTION 0 0 0

614 POSITIVE THERMAL GRADIENT -5.482 48.643 41.554

615 NEGATIVE THERMAL GRADIENT 5.482 -48.643 -41.554

12800 601 DEAD LOAD 0.023 22.75 -0.044

602 LIVE LOAD - BRIDGE WALKWAY -0.002 -2.782 0.009

603 FLUID LOADS - OPERATING CONDITION 1.23 1033.334 -2.618

Page 29
Project : OCP Benguerir
Description : Foundation Load (Reactions) Data
Structure : 45m Diameter High Rate Thickeners
Doc. No. : 2689A0TR045VB101 Rev. : A
Client : OCP, Morocco

604 FLUID LOADS - SANDED CONDITION 1.361 1143.742 -2.897

605 LIVE LOAD - TORQUE AND LIFTING - NORMAL OPERATING 0.001 -0.087 0.001

606 LIVE LOAD - TORQUE AND LIFTING - MAXIMUM 0.003 -0.272 0.001

607 WIND LOAD - Z DIRECTION 0.052 0.328 -0.211

608 WIND LOAD - X DIRECTION -0.028 1.121 0.037

609 SEISMIC LOAD - Z POSITIVE DIRECTION 1.316 -4.811 -2.57

610 SEISMIC LOAD - Z NEGATIVE DIRECTION -1.316 4.811 2.57

611 SEISMIC LOAD - X POSITIVE DIRECTION -0.023 40.142 1.237

612 SEISMIC LOAD - X NEGATIVE DIRECTION 0.023 -40.142 -1.237

613 SEISMIC LOAD - Y DIRECTION 0 0 0

614 POSITIVE THERMAL GRADIENT -0.11 -0.282 0.31

615 NEGATIVE THERMAL GRADIENT 0.11 0.282 -0.31

12801 601 DEAD LOAD 0.203 17.876 -0.273

602 LIVE LOAD - BRIDGE WALKWAY 0.228 -3.162 -0.301

603 FLUID LOADS - OPERATING CONDITION 32.924 688.671 -43.18

604 FLUID LOADS - SANDED CONDITION 36.427 762.31 -47.773

605 LIVE LOAD - TORQUE AND LIFTING - NORMAL OPERATING -0.038 0.127 0.052

606 LIVE LOAD - TORQUE AND LIFTING - MAXIMUM -0.041 0.155 0.059

607 WIND LOAD - Z DIRECTION 11.912 -37.584 -15.624

608 WIND LOAD - X DIRECTION -3.764 8.88 4.888

609 SEISMIC LOAD - Z POSITIVE DIRECTION 165.626 -511.122 -215.444

610 SEISMIC LOAD - Z NEGATIVE DIRECTION -165.626 511.122 215.444

611 SEISMIC LOAD - X POSITIVE DIRECTION -92.554 290.571 121.383

612 SEISMIC LOAD - X NEGATIVE DIRECTION 92.554 -290.571 -121.383

613 SEISMIC LOAD - Y DIRECTION 0 0 0

614 POSITIVE THERMAL GRADIENT -25.013 47.106 32.581

615 NEGATIVE THERMAL GRADIENT 25.013 -47.106 -32.581

12802 601 DEAD LOAD 0.046 23.68 -0.031

602 LIVE LOAD - BRIDGE WALKWAY -0.003 -2.178 0.004

Page 30
Project : OCP Benguerir
Description : Foundation Load (Reactions) Data
Structure : 45m Diameter High Rate Thickeners
Doc. No. : 2689A0TR045VB101 Rev. : A
Client : OCP, Morocco

603 FLUID LOADS - OPERATING CONDITION 2.374 1034.021 -1.659

604 FLUID LOADS - SANDED CONDITION 2.627 1144.417 -1.836

605 LIVE LOAD - TORQUE AND LIFTING - NORMAL OPERATING 0 -0.087 0.001

606 LIVE LOAD - TORQUE AND LIFTING - MAXIMUM 0.003 -0.271 0.002

607 WIND LOAD - Z DIRECTION 0.072 1.898 -0.144

608 WIND LOAD - X DIRECTION -0.063 5.902 0.023

609 SEISMIC LOAD - Z POSITIVE DIRECTION 1.756 15.223 -0.812

610 SEISMIC LOAD - Z NEGATIVE DIRECTION -1.756 -15.223 0.812

611 SEISMIC LOAD - X POSITIVE DIRECTION -1.684 49.973 1.597

612 SEISMIC LOAD - X NEGATIVE DIRECTION 1.684 -49.973 -1.597

613 SEISMIC LOAD - Y DIRECTION 0 0 0

614 POSITIVE THERMAL GRADIENT -0.244 -0.307 0.209

615 NEGATIVE THERMAL GRADIENT 0.244 0.307 -0.209

12803 601 DEAD LOAD 0.526 17.396 -0.223

602 LIVE LOAD - BRIDGE WALKWAY 0.474 -3.437 -0.198

603 FLUID LOADS - OPERATING CONDITION 50.263 688.265 -21.004

604 FLUID LOADS - SANDED CONDITION 55.588 761.909 -23.229

605 LIVE LOAD - TORQUE AND LIFTING - NORMAL OPERATING -0.059 0.127 0.026

606 LIVE LOAD - TORQUE AND LIFTING - MAXIMUM -0.067 0.158 0.031

607 WIND LOAD - Z DIRECTION 10.987 -20.909 -4.642

608 WIND LOAD - X DIRECTION -7.012 25.116 2.907

609 SEISMIC LOAD - Z POSITIVE DIRECTION 144.291 -286.752 -59.276

610 SEISMIC LOAD - Z NEGATIVE DIRECTION -144.291 286.752 59.276

611 SEISMIC LOAD - X POSITIVE DIRECTION -236.972 519.008 98.473

612 SEISMIC LOAD - X NEGATIVE DIRECTION 236.972 -519.008 -98.473

613 SEISMIC LOAD - Y DIRECTION 0 0 0

614 POSITIVE THERMAL GRADIENT -37.354 45.933 15.46

615 NEGATIVE THERMAL GRADIENT 37.354 -45.933 -15.46

12804 601 DEAD LOAD 0.013 16.626 0.005

Page 31
Project : OCP Benguerir
Description : Foundation Load (Reactions) Data
Structure : 45m Diameter High Rate Thickeners
Doc. No. : 2689A0TR045VB101 Rev. : A
Client : OCP, Morocco

602 LIVE LOAD - BRIDGE WALKWAY -0.033 -6.739 0.008

603 FLUID LOADS - OPERATING CONDITION 2.852 1028.257 -0.233

604 FLUID LOADS - SANDED CONDITION 3.16 1138.687 -0.259

605 LIVE LOAD - TORQUE AND LIFTING - NORMAL OPERATING 0 -0.089 0.001

606 LIVE LOAD - TORQUE AND LIFTING - MAXIMUM 0.001 -0.278 0.003

607 WIND LOAD - Z DIRECTION 0.045 5.853 -0.083

608 WIND LOAD - X DIRECTION -0.18 -13.884 0.026

609 SEISMIC LOAD - Z POSITIVE DIRECTION 0.488 36.063 0.443

610 SEISMIC LOAD - Z NEGATIVE DIRECTION -0.488 -36.063 -0.443

611 SEISMIC LOAD - X POSITIVE DIRECTION -3.101 -9.504 0.445

612 SEISMIC LOAD - X NEGATIVE DIRECTION 3.101 9.504 -0.445

613 SEISMIC LOAD - Y DIRECTION 0 0 0

614 POSITIVE THERMAL GRADIENT -0.311 -0.262 0.058

615 NEGATIVE THERMAL GRADIENT 0.311 0.262 -0.058

Page 32
Project : OCP Benguerir
Description : Foundation Load (Reactions) Data
Structure : 45m Diameter High Rate Thickeners
Doc. No. : 2689A0TR045VB101 Rev. : A
Client : OCP, Morocco

1.4 Support Reactions – Columns-PCD3

Page 33
Project : OCP Benguerir
Description : Foundation Load (Reactions) Data
Structure : 45m Diameter High Rate Thickeners
Doc. No. : 2689A0TR045VB101 Rev. : A
Client : OCP, Morocco

Horizontal Vertical Horizontal

Node L/C Fx kN Fy kN Fz kN

16597 601 DEAD LOAD 5.303 32.861 3.571

602 LIVE LOAD - BRIDGE WALKWAY -0.494 0.364 0.031

603 FLUID LOADS - OPERATING CONDITION 262.123 1214.028 117.791

604 FLUID LOADS - SANDED CONDITION 290.171 1343.636 130.339

605 LIVE LOAD - TORQUE AND LIFTING - NORMAL OPERATING -0.094 1.053 0.443

606 LIVE LOAD - TORQUE AND LIFTING - MAXIMUM -0.189 3.506 1.387

607 WIND LOAD - Z DIRECTION 0.29 -34.644 -11.728

608 WIND LOAD - X DIRECTION -12.239 6.18 11.643

609 SEISMIC LOAD - Z POSITIVE DIRECTION 16.456 -607.05 -223.377

610 SEISMIC LOAD - Z NEGATIVE DIRECTION -16.456 607.05 223.377

611 SEISMIC LOAD - X POSITIVE DIRECTION -268.4 -353.814 69.485

612 SEISMIC LOAD - X NEGATIVE DIRECTION 268.4 353.814 -69.485

613 SEISMIC LOAD - Y DIRECTION 0 0 0

614 POSITIVE THERMAL GRADIENT -7.573 -45.712 7.288

615 NEGATIVE THERMAL GRADIENT 7.573 45.712 -7.288

16598 601 DEAD LOAD 0.65 21.656 -2.227

602 LIVE LOAD - BRIDGE WALKWAY -0.076 -0.617 0.293

603 FLUID LOADS - OPERATING CONDITION 24.736 835.227 -82.907

604 FLUID LOADS - SANDED CONDITION 27.383 924.531 -91.783

605 LIVE LOAD - TORQUE AND LIFTING - NORMAL OPERATING -0.119 -1.102 0.446

606 LIVE LOAD - TORQUE AND LIFTING - MAXIMUM -0.36 -3.353 1.35

607 WIND LOAD - Z DIRECTION 3.87 32.895 -14.751

608 WIND LOAD - X DIRECTION -2.558 -27.463 9.104

609 SEISMIC LOAD - Z POSITIVE DIRECTION 60.159 568.77 -230.351

610 SEISMIC LOAD - Z NEGATIVE DIRECTION -60.159 -568.77 230.351

611 SEISMIC LOAD - X POSITIVE DIRECTION -28.197 -229.031 93.218

Page 34
Project : OCP Benguerir
Description : Foundation Load (Reactions) Data
Structure : 45m Diameter High Rate Thickeners
Doc. No. : 2689A0TR045VB101 Rev. : A
Client : OCP, Morocco

612 SEISMIC LOAD - X NEGATIVE DIRECTION 28.197 229.031 -93.218

613 SEISMIC LOAD - Y DIRECTION 0 0 0

614 POSITIVE THERMAL GRADIENT 0.672 -5.793 -3.535

615 NEGATIVE THERMAL GRADIENT -0.672 5.793 3.535

16599 601 DEAD LOAD 3.646 32.705 5.818

602 LIVE LOAD - BRIDGE WALKWAY 0.086 0.261 -0.171

603 FLUID LOADS - OPERATING CONDITION 168.797 1214.129 233.208

604 FLUID LOADS - SANDED CONDITION 186.81 1343.763 258.107

605 LIVE LOAD - TORQUE AND LIFTING - NORMAL OPERATING -0.303 1.051 0.336

606 LIVE LOAD - TORQUE AND LIFTING - MAXIMUM -0.858 3.5 1.105

607 WIND LOAD - Z DIRECTION -2.68 -35.9 -9.876

608 WIND LOAD - X DIRECTION -9.695 -1.227 -0.053

609 SEISMIC LOAD - Z POSITIVE DIRECTION -19.162 -738.339 -209.102

610 SEISMIC LOAD - Z NEGATIVE DIRECTION 19.162 738.339 209.102

611 SEISMIC LOAD - X POSITIVE DIRECTION -277.427 -50.354 10.044

612 SEISMIC LOAD - X NEGATIVE DIRECTION 277.427 50.354 -10.044

613 SEISMIC LOAD - Y DIRECTION 0 0 0

614 POSITIVE THERMAL GRADIENT -9.975 -46.1 2.392

615 NEGATIVE THERMAL GRADIENT 9.975 46.1 -2.392

16600 601 DEAD LOAD 1.635 22.126 -1.565

602 LIVE LOAD - BRIDGE WALKWAY -0.24 -0.327 0.241

603 FLUID LOADS - OPERATING CONDITION 62.786 835.447 -59.343

604 FLUID LOADS - SANDED CONDITION 69.511 924.73 -65.701

605 LIVE LOAD - TORQUE AND LIFTING - NORMAL OPERATING -0.326 -1.101 0.326

606 LIVE LOAD - TORQUE AND LIFTING - MAXIMUM -0.986 -3.351 0.989

607 WIND LOAD - Z DIRECTION 4.362 15.247 -4.605

608 WIND LOAD - X DIRECTION -7.188 -19.429 7.069

609 SEISMIC LOAD - Z POSITIVE DIRECTION 112.93 399.379 -117.09

610 SEISMIC LOAD - Z NEGATIVE DIRECTION -112.93 -399.379 117.09

Page 35
Project : OCP Benguerir
Description : Foundation Load (Reactions) Data
Structure : 45m Diameter High Rate Thickeners
Doc. No. : 2689A0TR045VB101 Rev. : A
Client : OCP, Morocco

611 SEISMIC LOAD - X POSITIVE DIRECTION -140.816 -445.13 137.986

612 SEISMIC LOAD - X NEGATIVE DIRECTION 140.816 445.13 -137.986

613 SEISMIC LOAD - Y DIRECTION 0 0 0

614 POSITIVE THERMAL GRADIENT 2.529 -5.188 -2.906

615 NEGATIVE THERMAL GRADIENT -2.529 5.188 2.906

16601 601 DEAD LOAD 0.148 32.32 6.75

602 LIVE LOAD - BRIDGE WALKWAY 0.094 0.017 -0.176

603 FLUID LOADS - OPERATING CONDITION 29.472 1213.821 286.263

604 FLUID LOADS - SANDED CONDITION 32.62 1343.459 316.832

605 LIVE LOAD - TORQUE AND LIFTING - NORMAL OPERATING -0.431 1.051 0.14

606 LIVE LOAD - TORQUE AND LIFTING - MAXIMUM -1.296 3.5 0.528

607 WIND LOAD - Z DIRECTION -3.161 -36.922 -13.139

608 WIND LOAD - X DIRECTION -11.175 13.69 -0.243

609 SEISMIC LOAD - Z POSITIVE DIRECTION -48.397 -676.21 -233.792

610 SEISMIC LOAD - Z NEGATIVE DIRECTION 48.397 676.21 233.792

611 SEISMIC LOAD - X POSITIVE DIRECTION -255.196 306.718 -21.213

612 SEISMIC LOAD - X NEGATIVE DIRECTION 255.196 -306.718 21.213

613 SEISMIC LOAD - Y DIRECTION 0 0 0

614 POSITIVE THERMAL GRADIENT -9.675 -46.939 -3.108

615 NEGATIVE THERMAL GRADIENT 9.675 46.939 3.108

16602 601 DEAD LOAD 2.477 22.435 -0.613

602 LIVE LOAD - BRIDGE WALKWAY -0.154 -0.137 0.041

603 FLUID LOADS - OPERATING CONDITION 84.247 835.644 -20.057

604 FLUID LOADS - SANDED CONDITION 93.246 924.92 -22.199

605 LIVE LOAD - TORQUE AND LIFTING - NORMAL OPERATING -0.446 -1.102 0.119

606 LIVE LOAD - TORQUE AND LIFTING - MAXIMUM -1.349 -3.351 0.363

607 WIND LOAD - Z DIRECTION 0.569 3.276 -0.376

608 WIND LOAD - X DIRECTION -8.844 -23.33 2.355

609 SEISMIC LOAD - Z POSITIVE DIRECTION 43.238 127.079 -15.3

Page 36
Project : OCP Benguerir
Description : Foundation Load (Reactions) Data
Structure : 45m Diameter High Rate Thickeners
Doc. No. : 2689A0TR045VB101 Rev. : A
Client : OCP, Morocco

610 SEISMIC LOAD - Z NEGATIVE DIRECTION -43.238 -127.079 15.3

611 SEISMIC LOAD - X POSITIVE DIRECTION -234.768 -570.878 62.581

612 SEISMIC LOAD - X NEGATIVE DIRECTION 234.768 570.878 -62.581

613 SEISMIC LOAD - Y DIRECTION 0 0 0

614 POSITIVE THERMAL GRADIENT 3.85 -4.66 -1.312

615 NEGATIVE THERMAL GRADIENT -3.85 4.66 1.312

16603 601 DEAD LOAD -3.234 32.266 5.906

602 LIVE LOAD - BRIDGE WALKWAY 0.175 -0.013 -0.115

603 FLUID LOADS - OPERATING CONDITION -117.61 1213.812 262.624

604 FLUID LOADS - SANDED CONDITION -130.169 1343.454 290.672

605 LIVE LOAD - TORQUE AND LIFTING - NORMAL OPERATING -0.443 1.051 -0.095

606 LIVE LOAD - TORQUE AND LIFTING - MAXIMUM -1.387 3.501 -0.191

607 WIND LOAD - Z DIRECTION -0.1 -29.473 -14.882

608 WIND LOAD - X DIRECTION -16.772 41.508 -2.415

609 SEISMIC LOAD - Z POSITIVE DIRECTION -41.379 -433.36 -271.256

610 SEISMIC LOAD - Z NEGATIVE DIRECTION 41.379 433.36 271.256

611 SEISMIC LOAD - X POSITIVE DIRECTION -217.312 588.021 -17.34

612 SEISMIC LOAD - X NEGATIVE DIRECTION 217.312 -588.021 17.34

613 SEISMIC LOAD - Y DIRECTION 0 0 0

614 POSITIVE THERMAL GRADIENT -6.62 -48.122 -7.835

615 NEGATIVE THERMAL GRADIENT 6.62 48.122 7.835

16604 601 DEAD LOAD 2.439 22.429 0.704

602 LIVE LOAD - BRIDGE WALKWAY -0.164 -0.146 -0.044

603 FLUID LOADS - OPERATING CONDITION 82.95 835.585 24.745

604 FLUID LOADS - SANDED CONDITION 91.812 924.856 27.388

605 LIVE LOAD - TORQUE AND LIFTING - NORMAL OPERATING -0.446 -1.102 -0.119

606 LIVE LOAD - TORQUE AND LIFTING - MAXIMUM -1.35 -3.352 -0.36

607 WIND LOAD - Z DIRECTION -3.809 -7.429 -1.229

608 WIND LOAD - X DIRECTION -15.708 -40.451 -4.141

Page 37
Project : OCP Benguerir
Description : Foundation Load (Reactions) Data
Structure : 45m Diameter High Rate Thickeners
Doc. No. : 2689A0TR045VB101 Rev. : A
Client : OCP, Morocco

609 SEISMIC LOAD - Z POSITIVE DIRECTION -79.469 -178.564 -24.679

610 SEISMIC LOAD - Z NEGATIVE DIRECTION 79.469 178.564 24.679

611 SEISMIC LOAD - X POSITIVE DIRECTION -223.913 -553.453 -58.496

612 SEISMIC LOAD - X NEGATIVE DIRECTION 223.913 553.453 58.496

613 SEISMIC LOAD - Y DIRECTION 0 0 0

614 POSITIVE THERMAL GRADIENT 4.103 -4.324 0.813

615 NEGATIVE THERMAL GRADIENT -4.103 4.324 -0.813

16605 601 DEAD LOAD -5.792 32.397 3.518

602 LIVE LOAD - BRIDGE WALKWAY 0.183 0.078 -0.001

603 FLUID LOADS - OPERATING CONDITION -233.202 1213.935 168.655

604 FLUID LOADS - SANDED CONDITION -258.103 1343.576 186.665

605 LIVE LOAD - TORQUE AND LIFTING - NORMAL OPERATING -0.337 1.052 -0.304

606 LIVE LOAD - TORQUE AND LIFTING - MAXIMUM -1.106 3.503 -0.859

607 WIND LOAD - Z DIRECTION 2.37 -12.919 -13.584

608 WIND LOAD - X DIRECTION -13.894 48.075 -2.528

609 SEISMIC LOAD - Z POSITIVE DIRECTION -5.385 -74.578 -283.865

610 SEISMIC LOAD - Z NEGATIVE DIRECTION 5.385 74.578 283.865

611 SEISMIC LOAD - X POSITIVE DIRECTION -202.774 715.63 16.782

612 SEISMIC LOAD - X NEGATIVE DIRECTION 202.774 -715.63 -16.782

613 SEISMIC LOAD - Y DIRECTION 0 0 0

614 POSITIVE THERMAL GRADIENT -1.449 -49.505 -10.492

615 NEGATIVE THERMAL GRADIENT 1.449 49.505 10.492

16606 601 DEAD LOAD 1.751 22.382 1.822

602 LIVE LOAD - BRIDGE WALKWAY -0.128 -0.181 -0.126

603 FLUID LOADS - OPERATING CONDITION 59.46 835.55 62.903

604 FLUID LOADS - SANDED CONDITION 65.813 924.822 69.624

605 LIVE LOAD - TORQUE AND LIFTING - NORMAL OPERATING -0.326 -1.103 -0.326

606 LIVE LOAD - TORQUE AND LIFTING - MAXIMUM -0.989 -3.353 -0.987

607 WIND LOAD - Z DIRECTION -5.29 -17.031 -5.473

Page 38
Project : OCP Benguerir
Description : Foundation Load (Reactions) Data
Structure : 45m Diameter High Rate Thickeners
Doc. No. : 2689A0TR045VB101 Rev. : A
Client : OCP, Morocco

608 WIND LOAD - X DIRECTION -10.227 -33.588 -10.033

609 SEISMIC LOAD - Z POSITIVE DIRECTION -132.557 -436.046 -135.496

610 SEISMIC LOAD - Z NEGATIVE DIRECTION 132.557 436.046 135.496

611 SEISMIC LOAD - X POSITIVE DIRECTION -114.961 -391.59 -110.967

612 SEISMIC LOAD - X NEGATIVE DIRECTION 114.961 391.59 110.967

613 SEISMIC LOAD - Y DIRECTION 0 0 0

614 POSITIVE THERMAL GRADIENT 3.133 -4.301 2.728

615 NEGATIVE THERMAL GRADIENT -3.133 4.301 -2.728

16607 601 DEAD LOAD -6.831 32.516 0.185

602 LIVE LOAD - BRIDGE WALKWAY 0.119 0.172 0.111

603 FLUID LOADS - OPERATING CONDITION -286.333 1214.009 29.497

604 FLUID LOADS - SANDED CONDITION -316.902 1343.647 32.644

605 LIVE LOAD - TORQUE AND LIFTING - NORMAL OPERATING -0.14 1.053 -0.431

606 LIVE LOAD - TORQUE AND LIFTING - MAXIMUM -0.529 3.506 -1.297

607 WIND LOAD - Z DIRECTION 1.538 12.753 -13.533

608 WIND LOAD - X DIRECTION -11.7 36.946 1.334

609 SEISMIC LOAD - Z POSITIVE DIRECTION 23.506 304.178 -258.944

610 SEISMIC LOAD - Z NEGATIVE DIRECTION -23.506 -304.178 258.944

611 SEISMIC LOAD - X POSITIVE DIRECTION -224.94 651.591 46.237

612 SEISMIC LOAD - X NEGATIVE DIRECTION 224.94 -651.591 -46.237

613 SEISMIC LOAD - Y DIRECTION 0 0 0

614 POSITIVE THERMAL GRADIENT 4.593 -50.88 -10.144

615 NEGATIVE THERMAL GRADIENT -4.593 50.88 10.144

16608 601 DEAD LOAD 0.609 22.407 2.469

602 LIVE LOAD - BRIDGE WALKWAY -0.046 -0.172 -0.166

603 FLUID LOADS - OPERATING CONDITION 20.047 835.579 84.22

604 FLUID LOADS - SANDED CONDITION 22.189 924.851 93.216

605 LIVE LOAD - TORQUE AND LIFTING - NORMAL OPERATING -0.12 -1.103 -0.446

606 LIVE LOAD - TORQUE AND LIFTING - MAXIMUM -0.363 -3.354 -1.35

Page 39
Project : OCP Benguerir
Description : Foundation Load (Reactions) Data
Structure : 45m Diameter High Rate Thickeners
Doc. No. : 2689A0TR045VB101 Rev. : A
Client : OCP, Morocco

607 WIND LOAD - Z DIRECTION -2.769 -27.343 -10.414

608 WIND LOAD - X DIRECTION -1.646 -12.299 -5.47

609 SEISMIC LOAD - Z POSITIVE DIRECTION -63.124 -576.58 -236.831

610 SEISMIC LOAD - Z NEGATIVE DIRECTION 63.124 576.58 236.831

611 SEISMIC LOAD - X POSITIVE DIRECTION -15.122 -125.307 -43.132

612 SEISMIC LOAD - X NEGATIVE DIRECTION 15.122 125.307 43.132

613 SEISMIC LOAD - Y DIRECTION 0 0 0

614 POSITIVE THERMAL GRADIENT 1.306 -4.642 3.728

615 NEGATIVE THERMAL GRADIENT -1.306 4.642 -3.728

16609 601 DEAD LOAD -6.051 32.544 -3.236

602 LIVE LOAD - BRIDGE WALKWAY 0.013 0.216 0.163

603 FLUID LOADS - OPERATING CONDITION -262.75 1214.038 -117.606

604 FLUID LOADS - SANDED CONDITION -290.796 1343.679 -130.166

605 LIVE LOAD - TORQUE AND LIFTING - NORMAL OPERATING 0.094 1.054 -0.444

606 LIVE LOAD - TORQUE AND LIFTING - MAXIMUM 0.189 3.51 -1.389

607 WIND LOAD - Z DIRECTION 1.956 48.917 -19.101

608 WIND LOAD - X DIRECTION -14.001 14.903 5.393

609 SEISMIC LOAD - Z POSITIVE DIRECTION 16.345 601.398 -221.436

610 SEISMIC LOAD - Z NEGATIVE DIRECTION -16.345 -601.398 221.436

611 SEISMIC LOAD - X POSITIVE DIRECTION -261.344 412.581 41.804

612 SEISMIC LOAD - X NEGATIVE DIRECTION 261.344 -412.581 -41.804

613 SEISMIC LOAD - Y DIRECTION 0 0 0

614 POSITIVE THERMAL GRADIENT 9.609 -53.141 -5.786

615 NEGATIVE THERMAL GRADIENT -9.609 53.141 5.786

16610 601 DEAD LOAD -0.716 22.478 2.473

602 LIVE LOAD - BRIDGE WALKWAY 0.038 -0.133 -0.149

603 FLUID LOADS - OPERATING CONDITION -24.754 835.63 82.979

604 FLUID LOADS - SANDED CONDITION -27.398 924.899 91.84

605 LIVE LOAD - TORQUE AND LIFTING - NORMAL OPERATING 0.119 -1.103 -0.446

Page 40
Project : OCP Benguerir
Description : Foundation Load (Reactions) Data
Structure : 45m Diameter High Rate Thickeners
Doc. No. : 2689A0TR045VB101 Rev. : A
Client : OCP, Morocco

606 LIVE LOAD - TORQUE AND LIFTING - MAXIMUM 0.36 -3.355 -1.351

607 WIND LOAD - Z DIRECTION 4.645 -45.708 -17.724

608 WIND LOAD - X DIRECTION -1.506 13.548 4.991

609 SEISMIC LOAD - Z POSITIVE DIRECTION 59.346 -562.534 -227.331

610 SEISMIC LOAD - Z NEGATIVE DIRECTION -59.346 562.534 227.331

611 SEISMIC LOAD - X POSITIVE DIRECTION -23.906 174.378 77.113

612 SEISMIC LOAD - X NEGATIVE DIRECTION 23.906 -174.378 -77.113

613 SEISMIC LOAD - Y DIRECTION 0 0 0

614 POSITIVE THERMAL GRADIENT -0.623 -4.273 3.522

615 NEGATIVE THERMAL GRADIENT 0.623 4.273 -3.522

16611 601 DEAD LOAD -3.628 32.483 -5.81

602 LIVE LOAD - BRIDGE WALKWAY -0.085 0.203 0.153

603 FLUID LOADS - OPERATING CONDITION -168.745 1213.969 -233.207

604 FLUID LOADS - SANDED CONDITION -186.755 1343.612 -258.108

605 LIVE LOAD - TORQUE AND LIFTING - NORMAL OPERATING 0.303 1.055 -0.338

606 LIVE LOAD - TORQUE AND LIFTING - MAXIMUM 0.856 3.514 -1.109

607 WIND LOAD - Z DIRECTION 0.892 60.164 -17.267

608 WIND LOAD - X DIRECTION -18.085 -10.015 4.915

609 SEISMIC LOAD - Z POSITIVE DIRECTION -19.739 737.366 -208.854

610 SEISMIC LOAD - Z NEGATIVE DIRECTION 19.739 -737.366 208.854

611 SEISMIC LOAD - X POSITIVE DIRECTION -275.597 62.342 8.279

612 SEISMIC LOAD - X NEGATIVE DIRECTION 275.597 -62.342 -8.279

613 SEISMIC LOAD - Y DIRECTION 0 0 0

614 POSITIVE THERMAL GRADIENT 12.489 -3.781 -1.117

615 NEGATIVE THERMAL GRADIENT -12.489 3.781 1.117

16612 601 DEAD LOAD -1.873 22.541 1.801

602 LIVE LOAD - BRIDGE WALKWAY 0.095 -0.09 -0.098

603 FLUID LOADS - OPERATING CONDITION -62.95 835.7 59.506

604 FLUID LOADS - SANDED CONDITION -69.67 924.971 65.859

Page 41
Project : OCP Benguerir
Description : Foundation Load (Reactions) Data
Structure : 45m Diameter High Rate Thickeners
Doc. No. : 2689A0TR045VB101 Rev. : A
Client : OCP, Morocco

605 LIVE LOAD - TORQUE AND LIFTING - NORMAL OPERATING 0.326 -1.102 -0.326

606 LIVE LOAD - TORQUE AND LIFTING - MAXIMUM 0.987 -3.354 -0.989

607 WIND LOAD - Z DIRECTION 10.816 -37.025 -11.105

608 WIND LOAD - X DIRECTION -10.312 34.574 10.158

609 SEISMIC LOAD - Z POSITIVE DIRECTION 112.324 -397.67 -116.487

610 SEISMIC LOAD - Z NEGATIVE DIRECTION -112.324 397.67 116.487

611 SEISMIC LOAD - X POSITIVE DIRECTION -132.399 427.398 129.594

612 SEISMIC LOAD - X NEGATIVE DIRECTION 132.399 -427.398 -129.594

613 SEISMIC LOAD - Y DIRECTION 0 0 0

614 POSITIVE THERMAL GRADIENT -5.979 0.48 6.414

615 NEGATIVE THERMAL GRADIENT 5.979 -0.48 -6.414

16613 601 DEAD LOAD -0.23 32.414 -6.816

602 LIVE LOAD - BRIDGE WALKWAY -0.155 0.17 0.101

603 FLUID LOADS - OPERATING CONDITION -29.518 1213.887 -286.302

604 FLUID LOADS - SANDED CONDITION -32.665 1343.529 -316.872

605 LIVE LOAD - TORQUE AND LIFTING - NORMAL OPERATING 0.431 1.056 -0.141

606 LIVE LOAD - TORQUE AND LIFTING - MAXIMUM 1.295 3.515 -0.534

607 WIND LOAD - Z DIRECTION -2.769 50.262 -16.621

608 WIND LOAD - X DIRECTION -17.032 -26.96 0.327

609 SEISMIC LOAD - Z POSITIVE DIRECTION -48.707 675.618 -233.777

610 SEISMIC LOAD - Z NEGATIVE DIRECTION 48.707 -675.618 233.777

611 SEISMIC LOAD - X POSITIVE DIRECTION -253.858 -305.501 -20.572

612 SEISMIC LOAD - X NEGATIVE DIRECTION 253.858 305.501 20.572

613 SEISMIC LOAD - Y DIRECTION 0 0 0

614 POSITIVE THERMAL GRADIENT 11.233 -50.077 4.907

615 NEGATIVE THERMAL GRADIENT -11.233 50.077 -4.907

16614 601 DEAD LOAD -2.521 22.553 0.624

602 LIVE LOAD - BRIDGE WALKWAY 0.125 -0.068 -0.035

603 FLUID LOADS - OPERATING CONDITION -84.26 835.694 20.059

Page 42
Project : OCP Benguerir
Description : Foundation Load (Reactions) Data
Structure : 45m Diameter High Rate Thickeners
Doc. No. : 2689A0TR045VB101 Rev. : A
Client : OCP, Morocco

604 FLUID LOADS - SANDED CONDITION -93.256 924.964 22.201

605 LIVE LOAD - TORQUE AND LIFTING - NORMAL OPERATING 0.445 -1.102 -0.119

606 LIVE LOAD - TORQUE AND LIFTING - MAXIMUM 1.349 -3.352 -0.363

607 WIND LOAD - Z DIRECTION 5.252 -12.677 -1.671

608 WIND LOAD - X DIRECTION -17.63 41.172 4.697

609 SEISMIC LOAD - Z POSITIVE DIRECTION 42.797 -126.164 -15.183

610 SEISMIC LOAD - Z NEGATIVE DIRECTION -42.797 126.164 15.183

611 SEISMIC LOAD - X POSITIVE DIRECTION -232.205 566.344 61.915

612 SEISMIC LOAD - X NEGATIVE DIRECTION 232.205 -566.344 -61.915

613 SEISMIC LOAD - Y DIRECTION 0 0 0

614 POSITIVE THERMAL GRADIENT -2.569 -7.209 0.994

615 NEGATIVE THERMAL GRADIENT 2.569 7.209 -0.994

16615 601 DEAD LOAD 3.194 32.354 -6.021

602 LIVE LOAD - BRIDGE WALKWAY -0.201 0.119 0.004

603 FLUID LOADS - OPERATING CONDITION 117.602 1213.907 -262.696

604 FLUID LOADS - SANDED CONDITION 130.165 1343.555 -290.743

605 LIVE LOAD - TORQUE AND LIFTING - NORMAL OPERATING 0.443 1.055 0.093

606 LIVE LOAD - TORQUE AND LIFTING - MAXIMUM 1.387 3.514 0.185

607 WIND LOAD - Z DIRECTION -5.574 25.604 -19.602

608 WIND LOAD - X DIRECTION -8.263 -24.187 -0.319

609 SEISMIC LOAD - Z POSITIVE DIRECTION -41.801 432.427 -271.322

610 SEISMIC LOAD - Z NEGATIVE DIRECTION 41.801 -432.427 271.322

611 SEISMIC LOAD - X POSITIVE DIRECTION -219.748 -594.924 -16.735

612 SEISMIC LOAD - X NEGATIVE DIRECTION 219.748 594.924 16.735

613 SEISMIC LOAD - Y DIRECTION 0 0 0

614 POSITIVE THERMAL GRADIENT 7.453 -48.276 9.131

615 NEGATIVE THERMAL GRADIENT -7.453 48.276 -9.131

16616 601 DEAD LOAD -2.527 22.61 -0.729

602 LIVE LOAD - BRIDGE WALKWAY 0.098 -0.012 0.024

Page 43
Project : OCP Benguerir
Description : Foundation Load (Reactions) Data
Structure : 45m Diameter High Rate Thickeners
Doc. No. : 2689A0TR045VB101 Rev. : A
Client : OCP, Morocco

603 FLUID LOADS - OPERATING CONDITION -82.998 835.669 -24.759

604 FLUID LOADS - SANDED CONDITION -91.857 924.933 -27.401

605 LIVE LOAD - TORQUE AND LIFTING - NORMAL OPERATING 0.445 -1.101 0.119

606 LIVE LOAD - TORQUE AND LIFTING - MAXIMUM 1.348 -3.349 0.359

607 WIND LOAD - Z DIRECTION -6.564 16.698 -2.005

608 WIND LOAD - X DIRECTION -10.018 22.64 -2.627

609 SEISMIC LOAD - Z POSITIVE DIRECTION -79.758 179.426 -24.755

610 SEISMIC LOAD - Z NEGATIVE DIRECTION 79.758 -179.426 24.755

611 SEISMIC LOAD - X POSITIVE DIRECTION -224.619 557.009 -58.667

612 SEISMIC LOAD - X NEGATIVE DIRECTION 224.619 -557.009 58.667

613 SEISMIC LOAD - Y DIRECTION 0 0 0

614 POSITIVE THERMAL GRADIENT -2.901 -7.064 -0.483

615 NEGATIVE THERMAL GRADIENT 2.901 7.064 0.483

16617 601 DEAD LOAD 5.549 32.005 -3.836

602 LIVE LOAD - BRIDGE WALKWAY -0.332 -0.136 -0.237

603 FLUID LOADS - OPERATING CONDITION 233.071 1213.776 -168.843

604 FLUID LOADS - SANDED CONDITION 257.98 1343.439 -186.846

605 LIVE LOAD - TORQUE AND LIFTING - NORMAL OPERATING 0.337 1.055 0.302

606 LIVE LOAD - TORQUE AND LIFTING - MAXIMUM 1.108 3.511 0.854

607 WIND LOAD - Z DIRECTION -4.08 -5.329 -23.211

608 WIND LOAD - X DIRECTION -9.906 -30.721 -1.001

609 SEISMIC LOAD - Z POSITIVE DIRECTION -6.058 72.661 -284.299

610 SEISMIC LOAD - Z NEGATIVE DIRECTION 6.058 -72.661 284.299

611 SEISMIC LOAD - X POSITIVE DIRECTION -211.743 -735.161 10.329

612 SEISMIC LOAD - X NEGATIVE DIRECTION 211.743 735.161 -10.329

613 SEISMIC LOAD - Y DIRECTION 0 0 0

614 POSITIVE THERMAL GRADIENT 2.291 -46.758 11.077

615 NEGATIVE THERMAL GRADIENT -2.291 46.758 -11.077

16618 601 DEAD LOAD -1.798 22.883 -1.87

Page 44
Project : OCP Benguerir
Description : Foundation Load (Reactions) Data
Structure : 45m Diameter High Rate Thickeners
Doc. No. : 2689A0TR045VB101 Rev. : A
Client : OCP, Morocco

602 LIVE LOAD - BRIDGE WALKWAY 0.086 0.179 0.084

603 FLUID LOADS - OPERATING CONDITION -59.463 835.789 -62.907

604 FLUID LOADS - SANDED CONDITION -65.813 925.042 -69.625

605 LIVE LOAD - TORQUE AND LIFTING - NORMAL OPERATING 0.326 -1.101 0.326

606 LIVE LOAD - TORQUE AND LIFTING - MAXIMUM 0.988 -3.348 0.985

607 WIND LOAD - Z DIRECTION -12.21 41.181 -12.433

608 WIND LOAD - X DIRECTION -3.706 16.12 -3.542

609 SEISMIC LOAD - Z POSITIVE DIRECTION -132.946 437.669 -135.881

610 SEISMIC LOAD - Z NEGATIVE DIRECTION 132.946 -437.669 135.881

611 SEISMIC LOAD - X POSITIVE DIRECTION -116.58 406.73 -112.556

612 SEISMIC LOAD - X NEGATIVE DIRECTION 116.58 -406.73 112.556

613 SEISMIC LOAD - Y DIRECTION 0 0 0

614 POSITIVE THERMAL GRADIENT -2.374 -6.843 -1.986

615 NEGATIVE THERMAL GRADIENT 2.374 6.843 1.986

16619 601 DEAD LOAD 6.859 31.919 -0.446

602 LIVE LOAD - BRIDGE WALKWAY -0.091 -0.216 -0.296

603 FLUID LOADS - OPERATING CONDITION 286.365 1213.709 -29.669

604 FLUID LOADS - SANDED CONDITION 316.935 1343.37 -32.812

605 LIVE LOAD - TORQUE AND LIFTING - NORMAL OPERATING 0.141 1.054 0.431

606 LIVE LOAD - TORQUE AND LIFTING - MAXIMUM 0.531 3.509 1.296

607 WIND LOAD - Z DIRECTION 0.339 -32.914 -22.84

608 WIND LOAD - X DIRECTION -8.804 -41.091 -4.888

609 SEISMIC LOAD - Z POSITIVE DIRECTION 22.601 -310.334 -261.805

610 SEISMIC LOAD - Z NEGATIVE DIRECTION -22.601 310.334 261.805

611 SEISMIC LOAD - X POSITIVE DIRECTION -226.433 -696.09 29.165

612 SEISMIC LOAD - X NEGATIVE DIRECTION 226.433 696.09 -29.165

613 SEISMIC LOAD - Y DIRECTION 0 0 0

614 POSITIVE THERMAL GRADIENT -3.121 -45.901 10.401

615 NEGATIVE THERMAL GRADIENT 3.121 45.901 -10.401

Page 45
Project : OCP Benguerir
Description : Foundation Load (Reactions) Data
Structure : 45m Diameter High Rate Thickeners
Doc. No. : 2689A0TR045VB101 Rev. : A
Client : OCP, Morocco

16620 601 DEAD LOAD -0.765 23.665 -3.054

602 LIVE LOAD - BRIDGE WALKWAY -0.06 0.684 -0.234

603 FLUID LOADS - OPERATING CONDITION -20.135 836.369 -84.549

604 FLUID LOADS - SANDED CONDITION -22.272 925.612 -93.528

605 LIVE LOAD - TORQUE AND LIFTING - NORMAL OPERATING 0.119 -1.102 0.445

606 LIVE LOAD - TORQUE AND LIFTING - MAXIMUM 0.363 -3.351 1.348

607 WIND LOAD - Z DIRECTION -5.94 53.078 -22.321

608 WIND LOAD - X DIRECTION -3.243 24.964 -11.661

609 SEISMIC LOAD - Z POSITIVE DIRECTION -63.621 582.272 -238.677

610 SEISMIC LOAD - Z NEGATIVE DIRECTION 63.621 -582.272 238.677

611 SEISMIC LOAD - X POSITIVE DIRECTION -22.519 181.812 -70.931

612 SEISMIC LOAD - X NEGATIVE DIRECTION 22.519 -181.812 70.931

613 SEISMIC LOAD - Y DIRECTION 0 0 0

614 POSITIVE THERMAL GRADIENT -1.118 -6.379 -3.131

615 NEGATIVE THERMAL GRADIENT 1.118 6.379 3.131

Page 46
Project : OCP Benguerir
Description : Foundation Load (Reactions) Data
Structure : 45m Diameter High Rate Thickeners
Doc. No. : 2689A0TR045VB101 Rev. : A
Client : OCP, Morocco

1.5 Support Reactions – Columns-PCD4

Page 47
Project : OCP Benguerir
Description : Foundation Load (Reactions) Data
Structure : 45m Diameter High Rate Thickeners
Doc. No. : 2689A0TR045VB101 Rev. : A
Client : OCP, Morocco

Horizontal Vertical Horizontal

Node L/C Fx kN Fy kN Fz kN

19417 601 DEAD LOAD 0.08 17.423 -0.011

602 LIVE LOAD - BRIDGE WALKWAY 0.011 -0.008 -0.002

603 FLUID LOADS - OPERATING CONDITION 3.711 633.988 -0.373

604 FLUID LOADS - SANDED CONDITION 4.107 701.738 -0.413

605 LIVE LOAD - TORQUE AND LIFTING - NORMAL OPERATING 0.001 0.032 0.003

606 LIVE LOAD - TORQUE AND LIFTING - MAXIMUM 0.007 -0.061 0.008

607 WIND LOAD - Z DIRECTION -0.058 -1.686 -0.055

608 WIND LOAD - X DIRECTION -0.161 -0.917 -0.039

609 SEISMIC LOAD - Z POSITIVE DIRECTION -1.235 -21.08 -0.079

610 SEISMIC LOAD - Z NEGATIVE DIRECTION 1.235 21.08 0.079

611 SEISMIC LOAD - X POSITIVE DIRECTION -5.108 -27.388 -0.419

612 SEISMIC LOAD - X NEGATIVE DIRECTION 5.108 27.388 0.419

613 SEISMIC LOAD - Y DIRECTION 0 0 0

614 POSITIVE THERMAL GRADIENT -0.322 -1.539 -0.106

615 NEGATIVE THERMAL GRADIENT 0.322 1.539 0.106

19418 601 DEAD LOAD 0.06 17.216 0.044

602 LIVE LOAD - BRIDGE WALKWAY 0.007 -0.055 0.005

603 FLUID LOADS - OPERATING CONDITION 2.939 627.964 2.108

604 FLUID LOADS - SANDED CONDITION 3.252 695.079 2.333

605 LIVE LOAD - TORQUE AND LIFTING - NORMAL OPERATING -0.001 -0.033 0.002

606 LIVE LOAD - TORQUE AND LIFTING - MAXIMUM 0 -0.263 0.008

607 WIND LOAD - Z DIRECTION -0.071 0.033 -0.076

608 WIND LOAD - X DIRECTION -0.168 -2.047 -0.122

609 SEISMIC LOAD - Z POSITIVE DIRECTION -1.444 7.552 -0.763

610 SEISMIC LOAD - Z NEGATIVE DIRECTION 1.444 -7.552 0.763

611 SEISMIC LOAD - X POSITIVE DIRECTION -4.268 -26.957 -2.186

Page 48
Project : OCP Benguerir
Description : Foundation Load (Reactions) Data
Structure : 45m Diameter High Rate Thickeners
Doc. No. : 2689A0TR045VB101 Rev. : A
Client : OCP, Morocco

612 SEISMIC LOAD - X NEGATIVE DIRECTION 4.268 26.957 2.186

613 SEISMIC LOAD - Y DIRECTION 0 0 0

614 POSITIVE THERMAL GRADIENT -0.292 -0.505 -0.043

615 NEGATIVE THERMAL GRADIENT 0.292 0.505 0.043

19419 601 DEAD LOAD 0.072 17.334 0.03

602 LIVE LOAD - BRIDGE WALKWAY 0.009 -0.058 0.003

603 FLUID LOADS - OPERATING CONDITION 3.4 633.893 1.532

604 FLUID LOADS - SANDED CONDITION 3.762 701.644 1.695

605 LIVE LOAD - TORQUE AND LIFTING - NORMAL OPERATING -0.001 0.031 0.003

606 LIVE LOAD - TORQUE AND LIFTING - MAXIMUM 0.002 -0.06 0.011

607 WIND LOAD - Z DIRECTION -0.166 -2.175 -0.144

608 WIND LOAD - X DIRECTION -0.139 -0.73 -0.075

609 SEISMIC LOAD - Z POSITIVE DIRECTION -3.152 -33.324 -2.119

610 SEISMIC LOAD - Z NEGATIVE DIRECTION 3.152 33.324 2.119

611 SEISMIC LOAD - X POSITIVE DIRECTION -3.269 -14.016 -2.193

612 SEISMIC LOAD - X NEGATIVE DIRECTION 3.269 14.016 2.193

613 SEISMIC LOAD - Y DIRECTION 0 0 0

614 POSITIVE THERMAL GRADIENT -0.224 -1.563 -0.253

615 NEGATIVE THERMAL GRADIENT 0.224 1.563 0.253

19420 601 DEAD LOAD 0.028 17.115 0.069

602 LIVE LOAD - BRIDGE WALKWAY 0.003 -0.109 0.008

603 FLUID LOADS - OPERATING CONDITION 1.491 627.848 3.295

604 FLUID LOADS - SANDED CONDITION 1.65 694.962 3.647

605 LIVE LOAD - TORQUE AND LIFTING - NORMAL OPERATING -0.002 -0.033 0.001

606 LIVE LOAD - TORQUE AND LIFTING - MAXIMUM -0.004 -0.262 0.007

607 WIND LOAD - Z DIRECTION -0.119 -1.145 -0.214

608 WIND LOAD - X DIRECTION -0.102 -1.325 -0.087

609 SEISMIC LOAD - Z POSITIVE DIRECTION -2.145 -6.69 -3.248

610 SEISMIC LOAD - Z NEGATIVE DIRECTION 2.145 6.69 3.248

Page 49
Project : OCP Benguerir
Description : Foundation Load (Reactions) Data
Structure : 45m Diameter High Rate Thickeners
Doc. No. : 2689A0TR045VB101 Rev. : A
Client : OCP, Morocco

611 SEISMIC LOAD - X POSITIVE DIRECTION -1.931 -25.831 -2.732

612 SEISMIC LOAD - X NEGATIVE DIRECTION 1.931 25.831 2.732

613 SEISMIC LOAD - Y DIRECTION 0 0 0

614 POSITIVE THERMAL GRADIENT -0.231 -0.489 -0.184

615 NEGATIVE THERMAL GRADIENT 0.231 0.489 0.184

19421 601 DEAD LOAD 0.046 17.199 0.062

602 LIVE LOAD - BRIDGE WALKWAY 0.005 -0.132 0.007

603 FLUID LOADS - OPERATING CONDITION 2.177 633.757 3.027

604 FLUID LOADS - SANDED CONDITION 2.409 701.508 3.349

605 LIVE LOAD - TORQUE AND LIFTING - NORMAL OPERATING -0.002 0.031 0.002

606 LIVE LOAD - TORQUE AND LIFTING - MAXIMUM -0.004 -0.058 0.011

607 WIND LOAD - Z DIRECTION -0.131 -2.601 -0.294

608 WIND LOAD - X DIRECTION -0.055 -0.242 -0.042

609 SEISMIC LOAD - Z POSITIVE DIRECTION -2.356 -36.839 -4.803

610 SEISMIC LOAD - Z NEGATIVE DIRECTION 2.356 36.839 4.803

611 SEISMIC LOAD - X POSITIVE DIRECTION -0.697 3.019 -1.432

612 SEISMIC LOAD - X NEGATIVE DIRECTION 0.697 -3.019 1.432

613 SEISMIC LOAD - Y DIRECTION 0 0 0

614 POSITIVE THERMAL GRADIENT -0.068 -1.579 -0.335

615 NEGATIVE THERMAL GRADIENT 0.068 1.579 0.335

19422 601 DEAD LOAD -0.009 17.029 0.073

602 LIVE LOAD - BRIDGE WALKWAY -0.001 -0.156 0.008

603 FLUID LOADS - OPERATING CONDITION -0.356 627.76 3.599

604 FLUID LOADS - SANDED CONDITION -0.394 694.874 3.983

605 LIVE LOAD - TORQUE AND LIFTING - NORMAL OPERATING -0.002 -0.033 0

606 LIVE LOAD - TORQUE AND LIFTING - MAXIMUM -0.007 -0.261 0.004

607 WIND LOAD - Z DIRECTION -0.018 -1.789 -0.315

608 WIND LOAD - X DIRECTION -0.05 -1.272 -0.029

609 SEISMIC LOAD - Z POSITIVE DIRECTION -0.347 -19.062 -5.093

Page 50
Project : OCP Benguerir
Description : Foundation Load (Reactions) Data
Structure : 45m Diameter High Rate Thickeners
Doc. No. : 2689A0TR045VB101 Rev. : A
Client : OCP, Morocco

610 SEISMIC LOAD - Z NEGATIVE DIRECTION 0.347 19.062 5.093

611 SEISMIC LOAD - X POSITIVE DIRECTION -0.115 -19.45 -1.031

612 SEISMIC LOAD - X NEGATIVE DIRECTION 0.115 19.45 1.031

613 SEISMIC LOAD - Y DIRECTION 0 0 0

614 POSITIVE THERMAL GRADIENT -0.108 -0.464 -0.281

615 NEGATIVE THERMAL GRADIENT 0.108 0.464 0.281

19423 601 DEAD LOAD 0.009 17.171 0.077

602 LIVE LOAD - BRIDGE WALKWAY 0.001 -0.147 0.008

603 FLUID LOADS - OPERATING CONDITION 0.372 633.731 3.71

604 FLUID LOADS - SANDED CONDITION 0.412 701.483 4.105

605 LIVE LOAD - TORQUE AND LIFTING - NORMAL OPERATING -0.003 0.031 0.001

606 LIVE LOAD - TORQUE AND LIFTING - MAXIMUM -0.008 -0.058 0.007

607 WIND LOAD - Z DIRECTION 0.021 -2.475 -0.336

608 WIND LOAD - X DIRECTION -0.016 0.993 0.073

609 SEISMIC LOAD - Z POSITIVE DIRECTION 0.37 -30.515 -5.454

610 SEISMIC LOAD - Z NEGATIVE DIRECTION -0.37 30.515 5.454

611 SEISMIC LOAD - X POSITIVE DIRECTION -0.068 20.187 1.18

612 SEISMIC LOAD - X NEGATIVE DIRECTION 0.068 -20.187 -1.18

613 SEISMIC LOAD - Y DIRECTION 0 0 0

614 POSITIVE THERMAL GRADIENT 0.109 -1.602 -0.333

615 NEGATIVE THERMAL GRADIENT -0.109 1.602 0.333

19424 601 DEAD LOAD -0.044 17.061 0.059

602 LIVE LOAD - BRIDGE WALKWAY -0.005 -0.138 0.007

603 FLUID LOADS - OPERATING CONDITION -2.108 627.787 2.939

604 FLUID LOADS - SANDED CONDITION -2.333 694.901 3.252

605 LIVE LOAD - TORQUE AND LIFTING - NORMAL OPERATING -0.002 -0.033 -0.001

606 LIVE LOAD - TORQUE AND LIFTING - MAXIMUM -0.008 -0.261 0

607 WIND LOAD - Z DIRECTION 0.121 -1.999 -0.274

608 WIND LOAD - X DIRECTION -0.056 -1.047 0.052

Page 51
Project : OCP Benguerir
Description : Foundation Load (Reactions) Data
Structure : 45m Diameter High Rate Thickeners
Doc. No. : 2689A0TR045VB101 Rev. : A
Client : OCP, Morocco

609 SEISMIC LOAD - Z POSITIVE DIRECTION 2.151 -26.297 -4.458

610 SEISMIC LOAD - Z NEGATIVE DIRECTION -2.151 26.297 4.458

611 SEISMIC LOAD - X POSITIVE DIRECTION -0.716 -7.622 1.377

612 SEISMIC LOAD - X NEGATIVE DIRECTION 0.716 7.622 -1.377

613 SEISMIC LOAD - Y DIRECTION 0 0 0

614 POSITIVE THERMAL GRADIENT 0.052 -0.467 -0.306

615 NEGATIVE THERMAL GRADIENT -0.052 0.467 0.306

19425 601 DEAD LOAD -0.03 17.255 0.071

602 LIVE LOAD - BRIDGE WALKWAY -0.003 -0.101 0.008

603 FLUID LOADS - OPERATING CONDITION -1.533 633.815 3.398

604 FLUID LOADS - SANDED CONDITION -1.696 701.565 3.761

605 LIVE LOAD - TORQUE AND LIFTING - NORMAL OPERATING -0.003 0.031 -0.001

606 LIVE LOAD - TORQUE AND LIFTING - MAXIMUM -0.011 -0.059 0.002

607 WIND LOAD - Z DIRECTION 0.132 -1.752 -0.223

608 WIND LOAD - X DIRECTION -0.13 1.781 0.145

609 SEISMIC LOAD - Z POSITIVE DIRECTION 2.297 -16.009 -3.419

610 SEISMIC LOAD - Z NEGATIVE DIRECTION -2.297 16.009 3.419

611 SEISMIC LOAD - X POSITIVE DIRECTION -2.021 32.107 3.033

612 SEISMIC LOAD - X NEGATIVE DIRECTION 2.021 -32.107 -3.033

613 SEISMIC LOAD - Y DIRECTION 0 0 0

614 POSITIVE THERMAL GRADIENT 0.268 -1.672 -0.244

615 NEGATIVE THERMAL GRADIENT -0.268 1.672 0.244

19426 601 DEAD LOAD -0.068 17.169 0.029

602 LIVE LOAD - BRIDGE WALKWAY -0.008 -0.08 0.003

603 FLUID LOADS - OPERATING CONDITION -3.295 627.903 1.491

604 FLUID LOADS - SANDED CONDITION -3.646 695.017 1.65

605 LIVE LOAD - TORQUE AND LIFTING - NORMAL OPERATING -0.001 -0.033 -0.002

606 LIVE LOAD - TORQUE AND LIFTING - MAXIMUM -0.007 -0.262 -0.004

607 WIND LOAD - Z DIRECTION 0.152 -1.762 -0.133

Page 52
Project : OCP Benguerir
Description : Foundation Load (Reactions) Data
Structure : 45m Diameter High Rate Thickeners
Doc. No. : 2689A0TR045VB101 Rev. : A
Client : OCP, Morocco

608 WIND LOAD - X DIRECTION -0.16 -0.32 0.08

609 SEISMIC LOAD - Z POSITIVE DIRECTION 2.849 -26.466 -1.976

610 SEISMIC LOAD - Z NEGATIVE DIRECTION -2.849 26.466 1.976

611 SEISMIC LOAD - X POSITIVE DIRECTION -3.099 6.119 2.059

612 SEISMIC LOAD - X NEGATIVE DIRECTION 3.099 -6.119 -2.059

613 SEISMIC LOAD - Y DIRECTION 0 0 0

614 POSITIVE THERMAL GRADIENT 0.209 -0.54 -0.246

615 NEGATIVE THERMAL GRADIENT -0.209 0.54 0.246

19427 601 DEAD LOAD -0.062 17.367 0.046

602 LIVE LOAD - BRIDGE WALKWAY -0.007 -0.04 0.005

603 FLUID LOADS - OPERATING CONDITION -3.026 633.937 2.177

604 FLUID LOADS - SANDED CONDITION -3.349 701.687 2.409

605 LIVE LOAD - TORQUE AND LIFTING - NORMAL OPERATING -0.002 0.032 -0.002

606 LIVE LOAD - TORQUE AND LIFTING - MAXIMUM -0.011 -0.06 -0.004

607 WIND LOAD - Z DIRECTION 0.079 -0.409 -0.076

608 WIND LOAD - X DIRECTION -0.24 1.769 0.103

609 SEISMIC LOAD - Z POSITIVE DIRECTION 1.497 2.797 -0.732

610 SEISMIC LOAD - Z NEGATIVE DIRECTION -1.497 -2.797 0.732

611 SEISMIC LOAD - X POSITIVE DIRECTION -4.602 35.39 2.265

612 SEISMIC LOAD - X NEGATIVE DIRECTION 4.602 -35.39 -2.265

613 SEISMIC LOAD - Y DIRECTION 0 0 0

614 POSITIVE THERMAL GRADIENT 0.368 -1.805 -0.084

615 NEGATIVE THERMAL GRADIENT -0.368 1.805 0.084

19428 601 DEAD LOAD -0.073 17.252 -0.009

602 LIVE LOAD - BRIDGE WALKWAY -0.009 -0.036 -0.001

603 FLUID LOADS - OPERATING CONDITION -3.599 627.999 -0.356

604 FLUID LOADS - SANDED CONDITION -3.982 695.113 -0.394

605 LIVE LOAD - TORQUE AND LIFTING - NORMAL OPERATING 0 -0.033 -0.002

606 LIVE LOAD - TORQUE AND LIFTING - MAXIMUM -0.004 -0.264 -0.007

Page 53
Project : OCP Benguerir
Description : Foundation Load (Reactions) Data
Structure : 45m Diameter High Rate Thickeners
Doc. No. : 2689A0TR045VB101 Rev. : A
Client : OCP, Morocco

607 WIND LOAD - Z DIRECTION 0.042 -1.387 -0.059

608 WIND LOAD - X DIRECTION -0.241 0.6 0.011

609 SEISMIC LOAD - Z POSITIVE DIRECTION 1.048 -19.532 -0.13

610 SEISMIC LOAD - Z NEGATIVE DIRECTION -1.048 19.532 0.13

611 SEISMIC LOAD - X POSITIVE DIRECTION -4.877 18.154 0.334

612 SEISMIC LOAD - X NEGATIVE DIRECTION 4.877 -18.154 -0.334

613 SEISMIC LOAD - Y DIRECTION 0 0 0

614 POSITIVE THERMAL GRADIENT 0.319 -0.675 -0.11

615 NEGATIVE THERMAL GRADIENT -0.319 0.675 0.11

19429 601 DEAD LOAD -0.077 17.4 0.009

602 LIVE LOAD - BRIDGE WALKWAY -0.009 -0.021 0.001

603 FLUID LOADS - OPERATING CONDITION -3.71 633.976 0.372

604 FLUID LOADS - SANDED CONDITION -4.105 701.727 0.412

605 LIVE LOAD - TORQUE AND LIFTING - NORMAL OPERATING -0.001 0.032 -0.003

606 LIVE LOAD - TORQUE AND LIFTING - MAXIMUM -0.008 -0.061 -0.008

607 WIND LOAD - Z DIRECTION -0.1 1.345 -0.023

608 WIND LOAD - X DIRECTION -0.259 1.151 -0.012

609 SEISMIC LOAD - Z POSITIVE DIRECTION -1.23 20.857 -0.081

610 SEISMIC LOAD - Z NEGATIVE DIRECTION 1.23 -20.857 0.081

611 SEISMIC LOAD - X POSITIVE DIRECTION -5.223 29.129 -0.354

612 SEISMIC LOAD - X NEGATIVE DIRECTION 5.223 -29.129 0.354

613 SEISMIC LOAD - Y DIRECTION 0 0 0

614 POSITIVE THERMAL GRADIENT 0.376 -1.927 0.114

615 NEGATIVE THERMAL GRADIENT -0.376 1.927 -0.114

19430 601 DEAD LOAD -0.06 17.229 -0.045

602 LIVE LOAD - BRIDGE WALKWAY -0.008 -0.046 -0.005

603 FLUID LOADS - OPERATING CONDITION -2.939 627.966 -2.108

604 FLUID LOADS - SANDED CONDITION -3.252 695.08 -2.333

605 LIVE LOAD - TORQUE AND LIFTING - NORMAL OPERATING 0.001 -0.033 -0.002

Page 54
Project : OCP Benguerir
Description : Foundation Load (Reactions) Data
Structure : 45m Diameter High Rate Thickeners
Doc. No. : 2689A0TR045VB101 Rev. : A
Client : OCP, Morocco

606 LIVE LOAD - TORQUE AND LIFTING - MAXIMUM 0 -0.263 -0.008

607 WIND LOAD - Z DIRECTION -0.092 -0.902 -0.083

608 WIND LOAD - X DIRECTION -0.223 1.263 -0.093

609 SEISMIC LOAD - Z POSITIVE DIRECTION -1.451 -7.36 -0.767

610 SEISMIC LOAD - Z NEGATIVE DIRECTION 1.451 7.36 0.767

611 SEISMIC LOAD - X POSITIVE DIRECTION -4.269 25.264 -2.066

612 SEISMIC LOAD - X NEGATIVE DIRECTION 4.269 -25.264 2.066

613 SEISMIC LOAD - Y DIRECTION 0 0 0

614 POSITIVE THERMAL GRADIENT 0.352 -0.728 0.049

615 NEGATIVE THERMAL GRADIENT -0.352 0.728 -0.049

19431 601 DEAD LOAD -0.072 17.323 -0.031

602 LIVE LOAD - BRIDGE WALKWAY -0.009 -0.059 -0.004

603 FLUID LOADS - OPERATING CONDITION -3.399 633.884 -1.533

604 FLUID LOADS - SANDED CONDITION -3.761 701.635 -1.696

605 LIVE LOAD - TORQUE AND LIFTING - NORMAL OPERATING 0.001 0.032 -0.003

606 LIVE LOAD - TORQUE AND LIFTING - MAXIMUM -0.002 -0.059 -0.011

607 WIND LOAD - Z DIRECTION -0.214 2.487 -0.183

608 WIND LOAD - X DIRECTION -0.168 0.128 -0.086

609 SEISMIC LOAD - Z POSITIVE DIRECTION -3.157 33.324 -2.117

610 SEISMIC LOAD - Z NEGATIVE DIRECTION 3.157 -33.324 2.117

611 SEISMIC LOAD - X POSITIVE DIRECTION -3.261 14.988 -2.199

612 SEISMIC LOAD - X NEGATIVE DIRECTION 3.261 -14.988 2.199

613 SEISMIC LOAD - Y DIRECTION 0 0 0

614 POSITIVE THERMAL GRADIENT 0.224 -0.771 0.276

615 NEGATIVE THERMAL GRADIENT -0.224 0.771 -0.276

19432 601 DEAD LOAD -0.03 17.127 -0.069

602 LIVE LOAD - BRIDGE WALKWAY -0.004 -0.098 -0.009

603 FLUID LOADS - OPERATING CONDITION -1.492 627.852 -3.296

604 FLUID LOADS - SANDED CONDITION -1.651 694.965 -3.647

Page 55
Project : OCP Benguerir
Description : Foundation Load (Reactions) Data
Structure : 45m Diameter High Rate Thickeners
Doc. No. : 2689A0TR045VB101 Rev. : A
Client : OCP, Morocco

605 LIVE LOAD - TORQUE AND LIFTING - NORMAL OPERATING 0.002 -0.033 -0.001

606 LIVE LOAD - TORQUE AND LIFTING - MAXIMUM 0.004 -0.261 -0.007

607 WIND LOAD - Z DIRECTION -0.13 0.096 -0.243

608 WIND LOAD - X DIRECTION -0.122 1.455 -0.13

609 SEISMIC LOAD - Z POSITIVE DIRECTION -2.149 6.781 -3.249

610 SEISMIC LOAD - Z NEGATIVE DIRECTION 2.149 -6.781 3.249

611 SEISMIC LOAD - X POSITIVE DIRECTION -1.884 25.544 -2.736

612 SEISMIC LOAD - X NEGATIVE DIRECTION 1.884 -25.544 2.736

613 SEISMIC LOAD - Y DIRECTION 0 0 0

614 POSITIVE THERMAL GRADIENT 0.264 -0.775 0.233

615 NEGATIVE THERMAL GRADIENT -0.264 0.775 -0.233

19433 601 DEAD LOAD -0.047 17.216 -0.064

602 LIVE LOAD - BRIDGE WALKWAY -0.006 -0.114 -0.009

603 FLUID LOADS - OPERATING CONDITION -2.178 633.768 -3.028

604 FLUID LOADS - SANDED CONDITION -2.41 701.519 -3.35

605 LIVE LOAD - TORQUE AND LIFTING - NORMAL OPERATING 0.002 0.032 -0.002

606 LIVE LOAD - TORQUE AND LIFTING - MAXIMUM 0.004 -0.057 -0.011

607 WIND LOAD - Z DIRECTION -0.154 2.638 -0.352

608 WIND LOAD - X DIRECTION -0.054 -0.826 -0.053

609 SEISMIC LOAD - Z POSITIVE DIRECTION -2.357 36.85 -4.804

610 SEISMIC LOAD - Z NEGATIVE DIRECTION 2.357 -36.85 4.804

611 SEISMIC LOAD - X POSITIVE DIRECTION -0.682 -3.254 -1.418

612 SEISMIC LOAD - X NEGATIVE DIRECTION 0.682 3.254 1.418

613 SEISMIC LOAD - Y DIRECTION 0 0 0

614 POSITIVE THERMAL GRADIENT 0.093 -1.872 0.377

615 NEGATIVE THERMAL GRADIENT -0.093 1.872 -0.377

19434 601 DEAD LOAD 0.009 17.048 -0.076

602 LIVE LOAD - BRIDGE WALKWAY 0.001 -0.138 -0.01

603 FLUID LOADS - OPERATING CONDITION 0.356 627.772 -3.601

Page 56
Project : OCP Benguerir
Description : Foundation Load (Reactions) Data
Structure : 45m Diameter High Rate Thickeners
Doc. No. : 2689A0TR045VB101 Rev. : A
Client : OCP, Morocco

604 FLUID LOADS - SANDED CONDITION 0.394 694.886 -3.984

605 LIVE LOAD - TORQUE AND LIFTING - NORMAL OPERATING 0.002 -0.033 0

606 LIVE LOAD - TORQUE AND LIFTING - MAXIMUM 0.007 -0.26 -0.004

607 WIND LOAD - Z DIRECTION -0.019 1.19 -0.362

608 WIND LOAD - X DIRECTION -0.017 0.918 -0.063

609 SEISMIC LOAD - Z POSITIVE DIRECTION -0.349 19.097 -5.094

610 SEISMIC LOAD - Z NEGATIVE DIRECTION 0.349 -19.097 5.094

611 SEISMIC LOAD - X POSITIVE DIRECTION -0.114 18.941 -1.002

612 SEISMIC LOAD - X NEGATIVE DIRECTION 0.114 -18.941 1.002

613 SEISMIC LOAD - Y DIRECTION 0 0 0

614 POSITIVE THERMAL GRADIENT 0.114 -0.719 0.317

615 NEGATIVE THERMAL GRADIENT -0.114 0.719 -0.317

19435 601 DEAD LOAD -0.009 17.182 -0.079

602 LIVE LOAD - BRIDGE WALKWAY -0.001 -0.133 -0.011

603 FLUID LOADS - OPERATING CONDITION -0.372 633.74 -3.711

604 FLUID LOADS - SANDED CONDITION -0.412 701.491 -4.107

605 LIVE LOAD - TORQUE AND LIFTING - NORMAL OPERATING 0.003 0.032 -0.001

606 LIVE LOAD - TORQUE AND LIFTING - MAXIMUM 0.008 -0.057 -0.008

607 WIND LOAD - Z DIRECTION 0.019 1.951 -0.386

608 WIND LOAD - X DIRECTION -0.049 -1.336 0.04

609 SEISMIC LOAD - Z POSITIVE DIRECTION 0.369 30.481 -5.453

610 SEISMIC LOAD - Z NEGATIVE DIRECTION -0.369 -30.481 5.453

611 SEISMIC LOAD - X POSITIVE DIRECTION -0.069 -20.75 1.21

612 SEISMIC LOAD - X NEGATIVE DIRECTION 0.069 20.75 -1.21

613 SEISMIC LOAD - Y DIRECTION 0 0 0

614 POSITIVE THERMAL GRADIENT -0.108 -1.705 0.356

615 NEGATIVE THERMAL GRADIENT 0.108 1.705 -0.356

19436 601 DEAD LOAD 0.045 17.075 -0.061

602 LIVE LOAD - BRIDGE WALKWAY 0.006 -0.124 -0.009

Page 57
Project : OCP Benguerir
Description : Foundation Load (Reactions) Data
Structure : 45m Diameter High Rate Thickeners
Doc. No. : 2689A0TR045VB101 Rev. : A
Client : OCP, Morocco

603 FLUID LOADS - OPERATING CONDITION 2.109 627.795 -2.94

604 FLUID LOADS - SANDED CONDITION 2.333 694.909 -3.253

605 LIVE LOAD - TORQUE AND LIFTING - NORMAL OPERATING 0.002 -0.033 0.001

606 LIVE LOAD - TORQUE AND LIFTING - MAXIMUM 0.008 -0.26 0

607 WIND LOAD - Z DIRECTION 0.138 1.89 -0.327

608 WIND LOAD - X DIRECTION -0.058 -0.106 0.045

609 SEISMIC LOAD - Z POSITIVE DIRECTION 2.149 26.293 -4.457

610 SEISMIC LOAD - Z NEGATIVE DIRECTION -2.149 -26.293 4.457

611 SEISMIC LOAD - X POSITIVE DIRECTION -0.73 7.418 1.391

612 SEISMIC LOAD - X NEGATIVE DIRECTION 0.73 -7.418 -1.391

613 SEISMIC LOAD - Y DIRECTION 0 0 0

614 POSITIVE THERMAL GRADIENT -0.053 -0.589 0.318

615 NEGATIVE THERMAL GRADIENT 0.053 0.589 -0.318

19437 601 DEAD LOAD 0.03 17.265 -0.073

602 LIVE LOAD - BRIDGE WALKWAY 0.004 -0.09 -0.01

603 FLUID LOADS - OPERATING CONDITION 1.533 633.825 -3.4

604 FLUID LOADS - SANDED CONDITION 1.696 701.576 -3.762

605 LIVE LOAD - TORQUE AND LIFTING - NORMAL OPERATING 0.003 0.032 0.001

606 LIVE LOAD - TORQUE AND LIFTING - MAXIMUM 0.011 -0.058 -0.002

607 WIND LOAD - Z DIRECTION 0.136 0.645 -0.254

608 WIND LOAD - X DIRECTION -0.109 -1.591 0.102

609 SEISMIC LOAD - Z POSITIVE DIRECTION 2.293 15.915 -3.417

610 SEISMIC LOAD - Z NEGATIVE DIRECTION -2.293 -15.915 3.417

611 SEISMIC LOAD - X POSITIVE DIRECTION -2.07 -32.441 3.031

612 SEISMIC LOAD - X NEGATIVE DIRECTION 2.07 32.441 -3.031

613 SEISMIC LOAD - Y DIRECTION 0 0 0

614 POSITIVE THERMAL GRADIENT -0.262 -1.57 0.242

615 NEGATIVE THERMAL GRADIENT 0.262 1.57 -0.242

19438 601 DEAD LOAD 0.07 17.205 -0.029

Page 58
Project : OCP Benguerir
Description : Foundation Load (Reactions) Data
Structure : 45m Diameter High Rate Thickeners
Doc. No. : 2689A0TR045VB101 Rev. : A
Client : OCP, Morocco

602 LIVE LOAD - BRIDGE WALKWAY 0.01 -0.053 -0.004

603 FLUID LOADS - OPERATING CONDITION 3.296 627.924 -1.491

604 FLUID LOADS - SANDED CONDITION 3.648 695.037 -1.65

605 LIVE LOAD - TORQUE AND LIFTING - NORMAL OPERATING 0.001 -0.033 0.002

606 LIVE LOAD - TORQUE AND LIFTING - MAXIMUM 0.007 -0.262 0.004

607 WIND LOAD - Z DIRECTION 0.188 2.018 -0.175

608 WIND LOAD - X DIRECTION -0.134 -0.401 0.072

609 SEISMIC LOAD - Z POSITIVE DIRECTION 2.844 26.48 -1.978

610 SEISMIC LOAD - Z NEGATIVE DIRECTION -2.844 -26.48 1.978

611 SEISMIC LOAD - X POSITIVE DIRECTION -3.102 -5.1 2.055

612 SEISMIC LOAD - X NEGATIVE DIRECTION 3.102 5.1 -2.055

613 SEISMIC LOAD - Y DIRECTION 0 0 0

614 POSITIVE THERMAL GRADIENT -0.194 -0.519 0.241

615 NEGATIVE THERMAL GRADIENT 0.194 0.519 -0.241

19439 601 DEAD LOAD 0.063 17.36 -0.046

602 LIVE LOAD - BRIDGE WALKWAY 0.009 -0.044 -0.005

603 FLUID LOADS - OPERATING CONDITION 3.027 633.942 -2.178

604 FLUID LOADS - SANDED CONDITION 3.35 701.694 -2.41

605 LIVE LOAD - TORQUE AND LIFTING - NORMAL OPERATING 0.002 0.032 0.002

606 LIVE LOAD - TORQUE AND LIFTING - MAXIMUM 0.011 -0.06 0.004

607 WIND LOAD - Z DIRECTION 0.088 -0.783 -0.078

608 WIND LOAD - X DIRECTION -0.18 -2.355 0.128

609 SEISMIC LOAD - Z POSITIVE DIRECTION 1.489 -2.987 -0.729

610 SEISMIC LOAD - Z NEGATIVE DIRECTION -1.489 2.987 0.729

611 SEISMIC LOAD - X POSITIVE DIRECTION -4.595 -36.911 2.378

612 SEISMIC LOAD - X NEGATIVE DIRECTION 4.595 36.911 -2.378

613 SEISMIC LOAD - Y DIRECTION 0 0 0

614 POSITIVE THERMAL GRADIENT -0.337 -1.526 0.073

615 NEGATIVE THERMAL GRADIENT 0.337 1.526 -0.073

Page 59
Project : OCP Benguerir
Description : Foundation Load (Reactions) Data
Structure : 45m Diameter High Rate Thickeners
Doc. No. : 2689A0TR045VB101 Rev. : A
Client : OCP, Morocco

19440 601 DEAD LOAD 0.077 17.289 0.01

602 LIVE LOAD - BRIDGE WALKWAY 0.011 -0.01 0.001

603 FLUID LOADS - OPERATING CONDITION 3.601 628.025 0.357

604 FLUID LOADS - SANDED CONDITION 3.985 695.139 0.395

605 LIVE LOAD - TORQUE AND LIFTING - NORMAL OPERATING 0 -0.033 0.002

606 LIVE LOAD - TORQUE AND LIFTING - MAXIMUM 0.004 -0.263 0.007

607 WIND LOAD - Z DIRECTION 0.092 1.457 -0.025

608 WIND LOAD - X DIRECTION -0.149 -0.536 0.037

609 SEISMIC LOAD - Z POSITIVE DIRECTION 1.053 19.759 -0.127

610 SEISMIC LOAD - Z NEGATIVE DIRECTION -1.053 -19.759 0.127

611 SEISMIC LOAD - X POSITIVE DIRECTION -4.764 -16.46 0.398

612 SEISMIC LOAD - X NEGATIVE DIRECTION 4.764 16.46 -0.398

613 SEISMIC LOAD - Y DIRECTION 0 0 0

614 POSITIVE THERMAL GRADIENT -0.279 -0.503 0.111

615 NEGATIVE THERMAL GRADIENT 0.279 0.503 -0.111

Page 60
Project : OCP Benguerir
Description : Foundation Load (Reactions) Data
Structure : 45m Diameter High Rate Thickeners
Doc. No. : 2689A0TR045VB101 Rev. : A
Client : OCP, Morocco

1.6 Support Reactions – Columns-PCD5

Page 61
Project : OCP Benguerir
Description : Foundation Load (Reactions) Data
Structure : 45m Diameter High Rate Thickeners
Doc. No. : 2689A0TR045VB101 Rev. : A
Client : OCP, Morocco

Horizontal Vertical Horizontal

Node L/C Fx kN Fy kN Fz kN

21265 601 DEAD LOAD 0.014 17.864 -0.006

602 LIVE LOAD - BRIDGE WALKWAY 0.001 0.26 -0.002

603 FLUID LOADS - OPERATING CONDITION 5.131 427.611 0.401

604 FLUID LOADS - SANDED CONDITION 5.68 473.253 0.444

605 LIVE LOAD - TORQUE AND LIFTING - NORMAL OPERATING -0.001 -0.021 0.01

606 LIVE LOAD - TORQUE AND LIFTING - MAXIMUM -0.018 0.283 0.027

607 WIND LOAD - Z DIRECTION -0.112 2.033 -0.083

608 WIND LOAD - X DIRECTION -0.472 3.416 -0.077

609 SEISMIC LOAD - Z POSITIVE DIRECTION -1.834 14.046 -0.654

610 SEISMIC LOAD - Z NEGATIVE DIRECTION 1.834 -14.046 0.654

611 SEISMIC LOAD - X POSITIVE DIRECTION -12.753 63.998 -1.55

612 SEISMIC LOAD - X NEGATIVE DIRECTION 12.753 -63.998 1.55

613 SEISMIC LOAD - Y DIRECTION 0 0 0

614 POSITIVE THERMAL GRADIENT -0.171 13.989 -0.031

615 NEGATIVE THERMAL GRADIENT 0.171 -13.989 0.031

21266 601 DEAD LOAD 0.006 17.964 0.007

602 LIVE LOAD - BRIDGE WALKWAY -0.002 0.3 -0.002

603 FLUID LOADS - OPERATING CONDITION 4.657 428.939 2.215

604 FLUID LOADS - SANDED CONDITION 5.156 474.715 2.452

605 LIVE LOAD - TORQUE AND LIFTING - NORMAL OPERATING -0.003 -0.002 0.009

606 LIVE LOAD - TORQUE AND LIFTING - MAXIMUM -0.024 0.344 0.022

607 WIND LOAD - Z DIRECTION -0.289 2.269 -0.213

608 WIND LOAD - X DIRECTION -0.42 2.822 -0.211

609 SEISMIC LOAD - Z POSITIVE DIRECTION -4.897 19.197 -2.572

610 SEISMIC LOAD - Z NEGATIVE DIRECTION 4.897 -19.197 2.572

611 SEISMIC LOAD - X POSITIVE DIRECTION -11.081 57.246 -4.628

Page 62
Project : OCP Benguerir
Description : Foundation Load (Reactions) Data
Structure : 45m Diameter High Rate Thickeners
Doc. No. : 2689A0TR045VB101 Rev. : A
Client : OCP, Morocco

612 SEISMIC LOAD - X NEGATIVE DIRECTION 11.081 -57.246 4.628

613 SEISMIC LOAD - Y DIRECTION 0 0 0

614 POSITIVE THERMAL GRADIENT -0.18 13.489 -0.041

615 NEGATIVE THERMAL GRADIENT 0.18 -13.489 0.041

21267 601 DEAD LOAD 0.001 18.008 -0.006

602 LIVE LOAD - BRIDGE WALKWAY -0.006 0.335 -0.006

603 FLUID LOADS - OPERATING CONDITION 4.229 427.788 2.905

604 FLUID LOADS - SANDED CONDITION 4.684 473.431 3.217

605 LIVE LOAD - TORQUE AND LIFTING - NORMAL OPERATING -0.005 -0.021 0.008

606 LIVE LOAD - TORQUE AND LIFTING - MAXIMUM -0.03 0.281 0.015

607 WIND LOAD - Z DIRECTION -0.387 3.548 -0.372

608 WIND LOAD - X DIRECTION -0.354 1.997 -0.254

609 SEISMIC LOAD - Z POSITIVE DIRECTION -6.52 44.893 -5.329

610 SEISMIC LOAD - Z NEGATIVE DIRECTION 6.52 -44.893 5.329

611 SEISMIC LOAD - X POSITIVE DIRECTION -8.385 46.291 -6.057

612 SEISMIC LOAD - X NEGATIVE DIRECTION 8.385 -46.291 6.057

613 SEISMIC LOAD - Y DIRECTION 0 0 0

614 POSITIVE THERMAL GRADIENT -0.129 14.032 -0.114

615 NEGATIVE THERMAL GRADIENT 0.129 -14.032 0.114

21268 601 DEAD LOAD -0.013 18.198 -0.005

602 LIVE LOAD - BRIDGE WALKWAY -0.009 0.424 -0.01

603 FLUID LOADS - OPERATING CONDITION 2.912 429.198 4.231

604 FLUID LOADS - SANDED CONDITION 3.226 474.974 4.686

605 LIVE LOAD - TORQUE AND LIFTING - NORMAL OPERATING -0.007 -0.002 0.007

606 LIVE LOAD - TORQUE AND LIFTING - MAXIMUM -0.032 0.341 0.007

607 WIND LOAD - Z DIRECTION -0.379 3.632 -0.588

608 WIND LOAD - X DIRECTION -0.254 2.256 -0.244

609 SEISMIC LOAD - Z POSITIVE DIRECTION -6.436 46.322 -9.023

610 SEISMIC LOAD - Z NEGATIVE DIRECTION 6.436 -46.322 9.023

Page 63
Project : OCP Benguerir
Description : Foundation Load (Reactions) Data
Structure : 45m Diameter High Rate Thickeners
Doc. No. : 2689A0TR045VB101 Rev. : A
Client : OCP, Morocco

611 SEISMIC LOAD - X POSITIVE DIRECTION -5.05 40.149 -6.035

612 SEISMIC LOAD - X NEGATIVE DIRECTION 5.05 -40.149 6.035

613 SEISMIC LOAD - Y DIRECTION 0 0 0

614 POSITIVE THERMAL GRADIENT -0.134 13.488 -0.129

615 NEGATIVE THERMAL GRADIENT 0.134 -13.488 0.129

21269 601 DEAD LOAD -0.004 18.296 -0.021

602 LIVE LOAD - BRIDGE WALKWAY -0.007 0.492 -0.017

603 FLUID LOADS - OPERATING CONDITION 2.202 428.088 4.614

604 FLUID LOADS - SANDED CONDITION 2.44 473.731 5.111

605 LIVE LOAD - TORQUE AND LIFTING - NORMAL OPERATING -0.009 -0.021 0.004

606 LIVE LOAD - TORQUE AND LIFTING - MAXIMUM -0.033 0.278 -0.002

607 WIND LOAD - Z DIRECTION -0.285 4.449 -0.747

608 WIND LOAD - X DIRECTION -0.156 1.86 -0.187

609 SEISMIC LOAD - Z POSITIVE DIRECTION -4.825 63.749 -11.729

610 SEISMIC LOAD - Z NEGATIVE DIRECTION 4.825 -63.749 11.729

611 SEISMIC LOAD - X POSITIVE DIRECTION -2.312 20.106 -4.42

612 SEISMIC LOAD - X NEGATIVE DIRECTION 2.312 -20.106 4.42

613 SEISMIC LOAD - Y DIRECTION 0 0 0

614 POSITIVE THERMAL GRADIENT -0.053 14.012 -0.169

615 NEGATIVE THERMAL GRADIENT 0.053 -14.012 0.169

21270 601 DEAD LOAD -0.009 18.4 -0.024

602 LIVE LOAD - BRIDGE WALKWAY -0.003 0.533 -0.021

603 FLUID LOADS - OPERATING CONDITION 0.405 429.411 5.107

604 FLUID LOADS - SANDED CONDITION 0.449 475.187 5.658

605 LIVE LOAD - TORQUE AND LIFTING - NORMAL OPERATING -0.009 -0.002 0.002

606 LIVE LOAD - TORQUE AND LIFTING - MAXIMUM -0.031 0.338 -0.009

607 WIND LOAD - Z DIRECTION -0.096 4.31 -0.855

608 WIND LOAD - X DIRECTION -0.066 1.794 -0.074

609 SEISMIC LOAD - Z POSITIVE DIRECTION -1.627 61.126 -13.584

Page 64
Project : OCP Benguerir
Description : Foundation Load (Reactions) Data
Structure : 45m Diameter High Rate Thickeners
Doc. No. : 2689A0TR045VB101 Rev. : A
Client : OCP, Morocco

610 SEISMIC LOAD - Z NEGATIVE DIRECTION 1.627 -61.126 13.584

611 SEISMIC LOAD - X POSITIVE DIRECTION -0.647 13.183 -1.445

612 SEISMIC LOAD - X NEGATIVE DIRECTION 0.647 -13.183 1.445

613 SEISMIC LOAD - Y DIRECTION 0 0 0

614 POSITIVE THERMAL GRADIENT -0.049 13.438 -0.188

615 NEGATIVE THERMAL GRADIENT 0.049 -13.438 0.188

21271 601 DEAD LOAD 0.009 18.359 -0.024

602 LIVE LOAD - BRIDGE WALKWAY 0.003 0.525 -0.021

603 FLUID LOADS - OPERATING CONDITION -0.397 428.158 5.092

604 FLUID LOADS - SANDED CONDITION -0.441 473.801 5.642

605 LIVE LOAD - TORQUE AND LIFTING - NORMAL OPERATING -0.01 -0.021 -0.001

606 LIVE LOAD - TORQUE AND LIFTING - MAXIMUM -0.028 0.276 -0.018

607 WIND LOAD - Z DIRECTION 0.094 4.584 -0.85

608 WIND LOAD - X DIRECTION 0.013 0.325 0.073

609 SEISMIC LOAD - Z POSITIVE DIRECTION 1.564 65.597 -13.462

610 SEISMIC LOAD - Z NEGATIVE DIRECTION -1.564 -65.597 13.462

611 SEISMIC LOAD - X POSITIVE DIRECTION -0.606 -13.2 1.721

612 SEISMIC LOAD - X NEGATIVE DIRECTION 0.606 13.2 -1.721

613 SEISMIC LOAD - Y DIRECTION 0 0 0

614 POSITIVE THERMAL GRADIENT 0.042 13.982 -0.187

615 NEGATIVE THERMAL GRADIENT -0.042 -13.982 0.187

21272 601 DEAD LOAD 0.003 18.326 -0.02

602 LIVE LOAD - BRIDGE WALKWAY 0.007 0.493 -0.017

603 FLUID LOADS - OPERATING CONDITION -2.203 429.338 4.63

604 FLUID LOADS - SANDED CONDITION -2.44 475.114 5.129

605 LIVE LOAD - TORQUE AND LIFTING - NORMAL OPERATING -0.009 -0.002 -0.003

606 LIVE LOAD - TORQUE AND LIFTING - MAXIMUM -0.022 0.339 -0.024

607 WIND LOAD - Z DIRECTION 0.284 4.231 -0.751

608 WIND LOAD - X DIRECTION -0.071 -0.149 0.238

Page 65
Project : OCP Benguerir
Description : Foundation Load (Reactions) Data
Structure : 45m Diameter High Rate Thickeners
Doc. No. : 2689A0TR045VB101 Rev. : A
Client : OCP, Morocco

609 SEISMIC LOAD - Z POSITIVE DIRECTION 4.729 59.547 -11.697

610 SEISMIC LOAD - Z NEGATIVE DIRECTION -4.729 -59.547 11.697

611 SEISMIC LOAD - X POSITIVE DIRECTION -2.442 -18.15 4.689

612 SEISMIC LOAD - X NEGATIVE DIRECTION 2.442 18.15 -4.689

613 SEISMIC LOAD - Y DIRECTION 0 0 0

614 POSITIVE THERMAL GRADIENT 0.06 13.429 -0.206

615 NEGATIVE THERMAL GRADIENT -0.06 -13.429 0.206

21273 601 DEAD LOAD 0.013 18.169 -0.006

602 LIVE LOAD - BRIDGE WALKWAY 0.009 0.424 -0.011

603 FLUID LOADS - OPERATING CONDITION -2.898 427.958 4.222

604 FLUID LOADS - SANDED CONDITION -3.21 473.601 4.676

605 LIVE LOAD - TORQUE AND LIFTING - NORMAL OPERATING -0.008 -0.021 -0.005

606 LIVE LOAD - TORQUE AND LIFTING - MAXIMUM -0.015 0.279 -0.03

607 WIND LOAD - Z DIRECTION 0.378 3.873 -0.58

608 WIND LOAD - X DIRECTION -0.217 -2.067 0.321

609 SEISMIC LOAD - Z POSITIVE DIRECTION 6.258 49.854 -8.791

610 SEISMIC LOAD - Z NEGATIVE DIRECTION -6.258 -49.854 8.791

611 SEISMIC LOAD - X POSITIVE DIRECTION -5.092 -43.189 6.266

612 SEISMIC LOAD - X NEGATIVE DIRECTION 5.092 43.189 -6.266

613 SEISMIC LOAD - Y DIRECTION 0 0 0

614 POSITIVE THERMAL GRADIENT 0.145 14.049 -0.163

615 NEGATIVE THERMAL GRADIENT -0.145 -14.049 0.163

21274 601 DEAD LOAD 0 18.07 -0.006

602 LIVE LOAD - BRIDGE WALKWAY 0.007 0.356 -0.005

603 FLUID LOADS - OPERATING CONDITION -4.237 429.061 2.919

604 FLUID LOADS - SANDED CONDITION -4.692 474.838 3.233

605 LIVE LOAD - TORQUE AND LIFTING - NORMAL OPERATING -0.007 -0.002 -0.007

606 LIVE LOAD - TORQUE AND LIFTING - MAXIMUM -0.007 0.342 -0.032

607 WIND LOAD - Z DIRECTION 0.382 3.338 -0.373

Page 66
Project : OCP Benguerir
Description : Foundation Load (Reactions) Data
Structure : 45m Diameter High Rate Thickeners
Doc. No. : 2689A0TR045VB101 Rev. : A
Client : OCP, Morocco

608 WIND LOAD - X DIRECTION -0.412 -2.258 0.326

609 SEISMIC LOAD - Z POSITIVE DIRECTION 6.27 41.987 -5.247

610 SEISMIC LOAD - Z NEGATIVE DIRECTION -6.27 -41.987 5.247

611 SEISMIC LOAD - X POSITIVE DIRECTION -8.652 -44.626 6.197

612 SEISMIC LOAD - X NEGATIVE DIRECTION 8.652 44.626 -6.197

613 SEISMIC LOAD - Y DIRECTION 0 0 0

614 POSITIVE THERMAL GRADIENT 0.182 13.565 -0.171

615 NEGATIVE THERMAL GRADIENT -0.182 -13.565 0.171

21275 601 DEAD LOAD -0.002 17.911 0.007

602 LIVE LOAD - BRIDGE WALKWAY 0.004 0.284 -0.001

603 FLUID LOADS - OPERATING CONDITION -4.637 427.677 2.214

604 FLUID LOADS - SANDED CONDITION -5.134 473.32 2.451

605 LIVE LOAD - TORQUE AND LIFTING - NORMAL OPERATING -0.004 -0.021 -0.009

606 LIVE LOAD - TORQUE AND LIFTING - MAXIMUM 0.002 0.282 -0.033

607 WIND LOAD - Z DIRECTION 0.275 2.317 -0.206

608 WIND LOAD - X DIRECTION -0.556 -3.572 0.246

609 SEISMIC LOAD - Z POSITIVE DIRECTION 4.558 20.729 -2.389

610 SEISMIC LOAD - Z NEGATIVE DIRECTION -4.558 -20.729 2.389

611 SEISMIC LOAD - X POSITIVE DIRECTION -11.262 -61.561 4.647

612 SEISMIC LOAD - X NEGATIVE DIRECTION 11.262 61.561 -4.647

613 SEISMIC LOAD - Y DIRECTION 0 0 0

614 POSITIVE THERMAL GRADIENT 0.245 14.273 -0.087

615 NEGATIVE THERMAL GRADIENT -0.245 -14.273 0.087

21276 601 DEAD LOAD -0.011 17.879 -0.004

602 LIVE LOAD - BRIDGE WALKWAY 0.001 0.252 -0.001

603 FLUID LOADS - OPERATING CONDITION -5.142 428.852 0.41

604 FLUID LOADS - SANDED CONDITION -5.693 474.628 0.454

605 LIVE LOAD - TORQUE AND LIFTING - NORMAL OPERATING -0.002 -0.002 -0.009

606 LIVE LOAD - TORQUE AND LIFTING - MAXIMUM 0.01 0.344 -0.031

Page 67
Project : OCP Benguerir
Description : Foundation Load (Reactions) Data
Structure : 45m Diameter High Rate Thickeners
Doc. No. : 2689A0TR045VB101 Rev. : A
Client : OCP, Morocco

607 WIND LOAD - Z DIRECTION 0.089 1.875 -0.088

608 WIND LOAD - X DIRECTION -0.656 -3.511 0.084

609 SEISMIC LOAD - Z POSITIVE DIRECTION 1.452 13.158 -0.686

610 SEISMIC LOAD - Z NEGATIVE DIRECTION -1.452 -13.158 0.686

611 SEISMIC LOAD - X POSITIVE DIRECTION -13.049 -59.038 1.568

612 SEISMIC LOAD - X NEGATIVE DIRECTION 13.049 59.038 -1.568

613 SEISMIC LOAD - Y DIRECTION 0 0 0

614 POSITIVE THERMAL GRADIENT 0.288 13.817 -0.065

615 NEGATIVE THERMAL GRADIENT -0.288 -13.817 0.065

21277 601 DEAD LOAD -0.011 17.835 0.004

602 LIVE LOAD - BRIDGE WALKWAY 0.001 0.24 0

603 FLUID LOADS - OPERATING CONDITION -5.128 427.595 -0.403

604 FLUID LOADS - SANDED CONDITION -5.677 473.239 -0.446

605 LIVE LOAD - TORQUE AND LIFTING - NORMAL OPERATING 0.001 -0.021 -0.01

606 LIVE LOAD - TORQUE AND LIFTING - MAXIMUM 0.018 0.283 -0.028

607 WIND LOAD - Z DIRECTION -0.132 -0.064 -0.016

608 WIND LOAD - X DIRECTION -0.649 -3.732 -0.081

609 SEISMIC LOAD - Z POSITIVE DIRECTION -1.838 -13.962 -0.661

610 SEISMIC LOAD - Z NEGATIVE DIRECTION 1.838 13.962 0.661

611 SEISMIC LOAD - X POSITIVE DIRECTION -12.928 -63.324 -1.504

612 SEISMIC LOAD - X NEGATIVE DIRECTION 12.928 63.324 1.504

613 SEISMIC LOAD - Y DIRECTION 0 0 0

614 POSITIVE THERMAL GRADIENT 0.301 14.484 0.042

615 NEGATIVE THERMAL GRADIENT -0.301 -14.484 -0.042

21278 601 DEAD LOAD -0.004 17.936 -0.009

602 LIVE LOAD - BRIDGE WALKWAY 0.002 0.278 0

603 FLUID LOADS - OPERATING CONDITION -4.655 428.92 -2.215

604 FLUID LOADS - SANDED CONDITION -5.154 474.697 -2.453

605 LIVE LOAD - TORQUE AND LIFTING - NORMAL OPERATING 0.003 -0.002 -0.009

Page 68
Project : OCP Benguerir
Description : Foundation Load (Reactions) Data
Structure : 45m Diameter High Rate Thickeners
Doc. No. : 2689A0TR045VB101 Rev. : A
Client : OCP, Morocco

606 LIVE LOAD - TORQUE AND LIFTING - MAXIMUM 0.024 0.343 -0.022

607 WIND LOAD - Z DIRECTION -0.358 -0.754 -0.145

608 WIND LOAD - X DIRECTION -0.551 -3.385 -0.241

609 SEISMIC LOAD - Z POSITIVE DIRECTION -4.907 -19.202 -2.578

610 SEISMIC LOAD - Z NEGATIVE DIRECTION 4.907 19.202 2.578

611 SEISMIC LOAD - X POSITIVE DIRECTION -11.223 -57.518 -4.547

612 SEISMIC LOAD - X NEGATIVE DIRECTION 11.223 57.518 4.547

613 SEISMIC LOAD - Y DIRECTION 0 0 0

614 POSITIVE THERMAL GRADIENT 0.329 13.971 0.078

615 NEGATIVE THERMAL GRADIENT -0.329 -13.971 -0.078

21279 601 DEAD LOAD -0.003 18.01 0.003

602 LIVE LOAD - BRIDGE WALKWAY 0.004 0.328 0.003

603 FLUID LOADS - OPERATING CONDITION -4.23 427.794 -2.907

604 FLUID LOADS - SANDED CONDITION -4.684 473.437 -3.219

605 LIVE LOAD - TORQUE AND LIFTING - NORMAL OPERATING 0.005 -0.021 -0.008

606 LIVE LOAD - TORQUE AND LIFTING - MAXIMUM 0.03 0.28 -0.015

607 WIND LOAD - Z DIRECTION -0.473 -3.1 -0.353

608 WIND LOAD - X DIRECTION -0.397 -2.451 -0.314

609 SEISMIC LOAD - Z POSITIVE DIRECTION -6.532 -44.907 -5.335

610 SEISMIC LOAD - Z NEGATIVE DIRECTION 6.532 44.907 5.335

611 SEISMIC LOAD - X POSITIVE DIRECTION -8.421 -47.995 -6.012

612 SEISMIC LOAD - X NEGATIVE DIRECTION 8.421 47.995 6.012

613 SEISMIC LOAD - Y DIRECTION 0 0 0

614 POSITIVE THERMAL GRADIENT 0.255 13.908 0.228

615 NEGATIVE THERMAL GRADIENT -0.255 -13.908 -0.228

21280 601 DEAD LOAD 0.01 18.18 0.002

602 LIVE LOAD - BRIDGE WALKWAY 0.006 0.403 0.007

603 FLUID LOADS - OPERATING CONDITION -2.914 429.191 -4.233

604 FLUID LOADS - SANDED CONDITION -3.227 474.967 -4.688

Page 69
Project : OCP Benguerir
Description : Foundation Load (Reactions) Data
Structure : 45m Diameter High Rate Thickeners
Doc. No. : 2689A0TR045VB101 Rev. : A
Client : OCP, Morocco

605 LIVE LOAD - TORQUE AND LIFTING - NORMAL OPERATING 0.007 -0.002 -0.007

606 LIVE LOAD - TORQUE AND LIFTING - MAXIMUM 0.032 0.339 -0.008

607 WIND LOAD - Z DIRECTION -0.47 -3.372 -0.627

608 WIND LOAD - X DIRECTION -0.208 -1.956 -0.304

609 SEISMIC LOAD - Z POSITIVE DIRECTION -6.447 -46.407 -9.03

610 SEISMIC LOAD - Z NEGATIVE DIRECTION 6.447 46.407 9.03

611 SEISMIC LOAD - X POSITIVE DIRECTION -5.004 -40.458 -6.008

612 SEISMIC LOAD - X NEGATIVE DIRECTION 5.004 40.458 6.008

613 SEISMIC LOAD - Y DIRECTION 0 0 0

614 POSITIVE THERMAL GRADIENT 0.207 13.927 0.255

615 NEGATIVE THERMAL GRADIENT -0.207 -13.927 -0.255

21281 601 DEAD LOAD 0.001 18.259 0.016

602 LIVE LOAD - BRIDGE WALKWAY 0.005 0.457 0.012

603 FLUID LOADS - OPERATING CONDITION -2.204 428.066 -4.617

604 FLUID LOADS - SANDED CONDITION -2.441 473.708 -5.114

605 LIVE LOAD - TORQUE AND LIFTING - NORMAL OPERATING 0.009 -0.022 -0.004

606 LIVE LOAD - TORQUE AND LIFTING - MAXIMUM 0.033 0.276 0.002

607 WIND LOAD - Z DIRECTION -0.353 -4.969 -0.827

608 WIND LOAD - X DIRECTION -0.059 -0.244 -0.215

609 SEISMIC LOAD - Z POSITIVE DIRECTION -4.831 -63.801 -11.735

610 SEISMIC LOAD - Z NEGATIVE DIRECTION 4.831 63.801 11.735

611 SEISMIC LOAD - X POSITIVE DIRECTION -2.257 -19.672 -4.347

612 SEISMIC LOAD - X NEGATIVE DIRECTION 2.257 19.672 4.347

613 SEISMIC LOAD - Y DIRECTION 0 0 0

614 POSITIVE THERMAL GRADIENT 0.105 14.448 0.279

615 NEGATIVE THERMAL GRADIENT -0.105 -14.448 -0.279

21282 601 DEAD LOAD 0.009 18.364 0.018

602 LIVE LOAD - BRIDGE WALKWAY 0.003 0.498 0.015

603 FLUID LOADS - OPERATING CONDITION -0.406 429.389 -5.111

Page 70
Project : OCP Benguerir
Description : Foundation Load (Reactions) Data
Structure : 45m Diameter High Rate Thickeners
Doc. No. : 2689A0TR045VB101 Rev. : A
Client : OCP, Morocco

604 FLUID LOADS - SANDED CONDITION -0.45 475.165 -5.662

605 LIVE LOAD - TORQUE AND LIFTING - NORMAL OPERATING 0.009 -0.002 -0.002

606 LIVE LOAD - TORQUE AND LIFTING - MAXIMUM 0.031 0.336 0.009

607 WIND LOAD - Z DIRECTION -0.12 -4.851 -0.964

608 WIND LOAD - X DIRECTION 0.011 0.367 -0.047

609 SEISMIC LOAD - Z POSITIVE DIRECTION -1.63 -61.156 -13.587

610 SEISMIC LOAD - Z NEGATIVE DIRECTION 1.63 61.156 13.587

611 SEISMIC LOAD - X POSITIVE DIRECTION -0.628 -12.489 -1.34

612 SEISMIC LOAD - X NEGATIVE DIRECTION 0.628 12.489 1.34

613 SEISMIC LOAD - Y DIRECTION 0 0 0

614 POSITIVE THERMAL GRADIENT 0.069 13.793 0.279

615 NEGATIVE THERMAL GRADIENT -0.069 -13.793 -0.279

21283 601 DEAD LOAD -0.008 18.333 0.018

602 LIVE LOAD - BRIDGE WALKWAY -0.002 0.496 0.015

603 FLUID LOADS - OPERATING CONDITION 0.398 428.141 -5.096

604 FLUID LOADS - SANDED CONDITION 0.441 473.784 -5.645

605 LIVE LOAD - TORQUE AND LIFTING - NORMAL OPERATING 0.01 -0.022 0.001

606 LIVE LOAD - TORQUE AND LIFTING - MAXIMUM 0.028 0.275 0.018

607 WIND LOAD - Z DIRECTION 0.113 -5.135 -0.952

608 WIND LOAD - X DIRECTION -0.068 1.846 0.1

609 SEISMIC LOAD - Z POSITIVE DIRECTION 1.561 -65.575 -13.459

610 SEISMIC LOAD - Z NEGATIVE DIRECTION -1.561 65.575 13.459

611 SEISMIC LOAD - X POSITIVE DIRECTION -0.624 13.93 1.828

612 SEISMIC LOAD - X NEGATIVE DIRECTION 0.624 -13.93 -1.828

613 SEISMIC LOAD - Y DIRECTION 0 0 0

614 POSITIVE THERMAL GRADIENT -0.039 14.189 0.247

615 NEGATIVE THERMAL GRADIENT 0.039 -14.189 -0.247

21284 601 DEAD LOAD -0.001 18.304 0.015

602 LIVE LOAD - BRIDGE WALKWAY -0.005 0.468 0.012

Page 71
Project : OCP Benguerir
Description : Foundation Load (Reactions) Data
Structure : 45m Diameter High Rate Thickeners
Doc. No. : 2689A0TR045VB101 Rev. : A
Client : OCP, Morocco

603 FLUID LOADS - OPERATING CONDITION 2.204 429.324 -4.634

604 FLUID LOADS - SANDED CONDITION 2.442 475.1 -5.133

605 LIVE LOAD - TORQUE AND LIFTING - NORMAL OPERATING 0.009 -0.002 0.003

606 LIVE LOAD - TORQUE AND LIFTING - MAXIMUM 0.022 0.337 0.024

607 WIND LOAD - Z DIRECTION 0.34 -4.622 -0.815

608 WIND LOAD - X DIRECTION -0.167 1.848 0.21

609 SEISMIC LOAD - Z POSITIVE DIRECTION 4.723 -59.504 -11.69

610 SEISMIC LOAD - Z NEGATIVE DIRECTION -4.723 59.504 11.69

611 SEISMIC LOAD - X POSITIVE DIRECTION -2.497 18.604 4.767

612 SEISMIC LOAD - X NEGATIVE DIRECTION 2.497 -18.604 -4.767

613 SEISMIC LOAD - Y DIRECTION 0 0 0

614 POSITIVE THERMAL GRADIENT -0.059 13.528 0.233

615 NEGATIVE THERMAL GRADIENT 0.059 -13.528 -0.233

21285 601 DEAD LOAD -0.01 18.137 0.002

602 LIVE LOAD - BRIDGE WALKWAY -0.006 0.393 0.007

603 FLUID LOADS - OPERATING CONDITION 2.9 427.934 -4.224

604 FLUID LOADS - SANDED CONDITION 3.212 473.578 -4.679

605 LIVE LOAD - TORQUE AND LIFTING - NORMAL OPERATING 0.008 -0.022 0.005

606 LIVE LOAD - TORQUE AND LIFTING - MAXIMUM 0.015 0.277 0.029

607 WIND LOAD - Z DIRECTION 0.445 -3.533 -0.601

608 WIND LOAD - X DIRECTION -0.261 2.399 0.262

609 SEISMIC LOAD - Z POSITIVE DIRECTION 6.247 -49.774 -8.784

610 SEISMIC LOAD - Z NEGATIVE DIRECTION -6.247 49.774 8.784

611 SEISMIC LOAD - X POSITIVE DIRECTION -5.138 42.927 6.299

612 SEISMIC LOAD - X NEGATIVE DIRECTION 5.138 -42.927 -6.299

613 SEISMIC LOAD - Y DIRECTION 0 0 0

614 POSITIVE THERMAL GRADIENT -0.131 13.97 0.162

615 NEGATIVE THERMAL GRADIENT 0.131 -13.97 -0.162

21286 601 DEAD LOAD 0.005 18.025 0.004

Page 72
Project : OCP Benguerir
Description : Foundation Load (Reactions) Data
Structure : 45m Diameter High Rate Thickeners
Doc. No. : 2689A0TR045VB101 Rev. : A
Client : OCP, Morocco

602 LIVE LOAD - BRIDGE WALKWAY -0.003 0.319 0.003

603 FLUID LOADS - OPERATING CONDITION 4.24 429.03 -2.921

604 FLUID LOADS - SANDED CONDITION 4.695 474.808 -3.235

605 LIVE LOAD - TORQUE AND LIFTING - NORMAL OPERATING 0.007 -0.002 0.007

606 LIVE LOAD - TORQUE AND LIFTING - MAXIMUM 0.007 0.341 0.032

607 WIND LOAD - Z DIRECTION 0.44 -2.895 -0.337

608 WIND LOAD - X DIRECTION -0.366 1.897 0.268

609 SEISMIC LOAD - Z POSITIVE DIRECTION 6.257 -41.984 -5.24

610 SEISMIC LOAD - Z NEGATIVE DIRECTION -6.257 41.984 5.24

611 SEISMIC LOAD - X POSITIVE DIRECTION -8.619 42.931 6.25

612 SEISMIC LOAD - X NEGATIVE DIRECTION 8.619 -42.931 -6.25

613 SEISMIC LOAD - Y DIRECTION 0 0 0

614 POSITIVE THERMAL GRADIENT -0.14 13.408 0.152

615 NEGATIVE THERMAL GRADIENT 0.14 -13.408 -0.152

21287 601 DEAD LOAD 0.007 17.92 -0.008

602 LIVE LOAD - BRIDGE WALKWAY 0 0.286 0.001

603 FLUID LOADS - OPERATING CONDITION 4.641 427.677 -2.215

604 FLUID LOADS - SANDED CONDITION 5.138 473.319 -2.452

605 LIVE LOAD - TORQUE AND LIFTING - NORMAL OPERATING 0.004 -0.021 0.009

606 LIVE LOAD - TORQUE AND LIFTING - MAXIMUM -0.002 0.282 0.033

607 WIND LOAD - Z DIRECTION 0.322 -0.846 -0.125

608 WIND LOAD - X DIRECTION -0.427 2.978 0.216

609 SEISMIC LOAD - Z POSITIVE DIRECTION 4.548 -20.728 -2.384

610 SEISMIC LOAD - Z NEGATIVE DIRECTION -4.548 20.728 2.384

611 SEISMIC LOAD - X POSITIVE DIRECTION -11.129 61.28 4.725

612 SEISMIC LOAD - X NEGATIVE DIRECTION 11.129 -61.28 -4.725

613 SEISMIC LOAD - Y DIRECTION 0 0 0

614 POSITIVE THERMAL GRADIENT -0.172 13.929 0.065

615 NEGATIVE THERMAL GRADIENT 0.172 -13.929 -0.065

Page 73
Project : OCP Benguerir
Description : Foundation Load (Reactions) Data
Structure : 45m Diameter High Rate Thickeners
Doc. No. : 2689A0TR045VB101 Rev. : A
Client : OCP, Morocco

21288 601 DEAD LOAD 0.015 17.905 0.005

602 LIVE LOAD - BRIDGE WALKWAY 0.002 0.267 0.001

603 FLUID LOADS - OPERATING CONDITION 5.146 428.859 -0.41

604 FLUID LOADS - SANDED CONDITION 5.697 474.634 -0.454

605 LIVE LOAD - TORQUE AND LIFTING - NORMAL OPERATING 0.002 -0.002 0.009

606 LIVE LOAD - TORQUE AND LIFTING - MAXIMUM -0.01 0.344 0.031

607 WIND LOAD - Z DIRECTION 0.099 -0.062 -0.012

608 WIND LOAD - X DIRECTION -0.477 3.293 0.08

609 SEISMIC LOAD - Z POSITIVE DIRECTION 1.447 -13.254 -0.679

610 SEISMIC LOAD - Z NEGATIVE DIRECTION -1.447 13.254 0.679

611 SEISMIC LOAD - X POSITIVE DIRECTION -12.875 59.787 1.611

612 SEISMIC LOAD - X NEGATIVE DIRECTION 12.875 -59.787 -1.611

613 SEISMIC LOAD - Y DIRECTION 0 0 0

614 POSITIVE THERMAL GRADIENT -0.181 13.432 0.059

615 NEGATIVE THERMAL GRADIENT 0.181 -13.432 -0.059

Page 74
Project : OCP Benguerir
Description : Foundation Load (Reactions) Data
Structure : 45m Diameter High Rate Thickeners
Doc. No. : 2689A0TR045VB101 Rev. : A
Client : OCP, Morocco

1.7 Support Reactions – Centre Column

Page 75
Project : OCP Benguerir
Description : Foundation Load (Reactions) Data
Structure : 45m Diameter High Rate Thickeners
Doc. No. : 2689A0TR045VB101 Rev. : A
Client : OCP, Morocco

Horizontal Vertical Horizontal

Node L/C Fx kN Fy kN Fz kN

26509 601 DEAD LOAD -19.389 55.327 -2.67

602 LIVE LOAD - BRIDGE WALKWAY -2.766 8.537 -0.353

603 FLUID LOADS - OPERATING CONDITION -93.489 262.965 -9.298

604 FLUID LOADS - SANDED CONDITION -102.87 289.168 -10.182

605 LIVE LOAD - TORQUE AND LIFTING - NORMAL OPERATING -1.199 0.015 9.027

606 LIVE LOAD - TORQUE AND LIFTING - MAXIMUM -6.729 8.553 27.38

607 WIND LOAD - Z DIRECTION -5.513 9.443 15.65

608 WIND LOAD - X DIRECTION -11.134 26.599 -1.125

609 SEISMIC LOAD - Z POSITIVE DIRECTION -36.682 88.209 -9.495

610 SEISMIC LOAD - Z NEGATIVE DIRECTION 36.682 -88.209 9.495

611 SEISMIC LOAD - X POSITIVE DIRECTION -234.547 539.994 -24.678

612 SEISMIC LOAD - X NEGATIVE DIRECTION 234.547 -539.994 24.678

613 SEISMIC LOAD - Y DIRECTION 0 0 0

614 POSITIVE THERMAL GRADIENT 4.116 -10.896 0.416

615 NEGATIVE THERMAL GRADIENT -4.116 10.896 -0.416

26512 601 DEAD LOAD -17.845 55.059 -8.208

602 LIVE LOAD - BRIDGE WALKWAY -2.481 8.44 -1.385

603 FLUID LOADS - OPERATING CONDITION -87.743 262.639 -33.858

604 FLUID LOADS - SANDED CONDITION -96.584 288.844 -37.14

605 LIVE LOAD - TORQUE AND LIFTING - NORMAL OPERATING -3.501 0.017 8.41

606 LIVE LOAD - TORQUE AND LIFTING - MAXIMUM -13.609 8.566 24.715

607 WIND LOAD - Z DIRECTION -14.154 25.685 10.619

608 WIND LOAD - X DIRECTION -9.73 24.527 -3.528

609 SEISMIC LOAD - Z POSITIVE DIRECTION -93.413 243.029 -43.135

Page 76
Project : OCP Benguerir
Description : Foundation Load (Reactions) Data
Structure : 45m Diameter High Rate Thickeners
Doc. No. : 2689A0TR045VB101 Rev. : A
Client : OCP, Morocco

610 SEISMIC LOAD - Z NEGATIVE DIRECTION 93.413 -243.029 43.135

611 SEISMIC LOAD - X POSITIVE DIRECTION -208.162 501.197 -69.855

612 SEISMIC LOAD - X NEGATIVE DIRECTION 208.162 -501.197 69.855

613 SEISMIC LOAD - Y DIRECTION 0 0 0

614 POSITIVE THERMAL GRADIENT 4.025 -11.232 1.473

615 NEGATIVE THERMAL GRADIENT -4.025 11.232 -1.473

26515 601 DEAD LOAD -14.877 54.509 -12.888

602 LIVE LOAD - BRIDGE WALKWAY -1.926 8.194 -2.17

603 FLUID LOADS - OPERATING CONDITION -75.63 261.973 -55.814

604 FLUID LOADS - SANDED CONDITION -83.308 288.175 -61.277

605 LIVE LOAD - TORQUE AND LIFTING - NORMAL OPERATING -5.55 0.019 7.216

606 LIVE LOAD - TORQUE AND LIFTING - MAXIMUM -19.517 8.577 20.349

607 WIND LOAD - Z DIRECTION -19.116 40.352 1.874

608 WIND LOAD - X DIRECTION -7.27 20.687 -4.864

609 SEISMIC LOAD - Z POSITIVE DIRECTION -125.602 381.336 -100.694

610 SEISMIC LOAD - Z NEGATIVE DIRECTION 125.602 -381.336 100.694

611 SEISMIC LOAD - X POSITIVE DIRECTION -161.88 427.97 -95.693

612 SEISMIC LOAD - X NEGATIVE DIRECTION 161.88 -427.97 95.693

613 SEISMIC LOAD - Y DIRECTION 0 0 0

614 POSITIVE THERMAL GRADIENT 3.56 -11.303 2.441

615 NEGATIVE THERMAL GRADIENT -3.56 11.303 -2.441

26518 601 DEAD LOAD -11.001 53.858 -16.358

602 LIVE LOAD - BRIDGE WALKWAY -1.281 7.885 -2.64

603 FLUID LOADS - OPERATING CONDITION -58.496 261.227 -73.559

604 FLUID LOADS - SANDED CONDITION -64.487 287.431 -80.826

605 LIVE LOAD - TORQUE AND LIFTING - NORMAL OPERATING -7.229 0.02 5.541

606 LIVE LOAD - TORQUE AND LIFTING - MAXIMUM -24.118 8.591 14.628

607 WIND LOAD - Z DIRECTION -19.024 52.388 -8.247

608 WIND LOAD - X DIRECTION -4.514 15.473 -4.777

Page 77
Project : OCP Benguerir
Description : Foundation Load (Reactions) Data
Structure : 45m Diameter High Rate Thickeners
Doc. No. : 2689A0TR045VB101 Rev. : A
Client : OCP, Morocco

609 SEISMIC LOAD - Z POSITIVE DIRECTION -124.547 493.67 -166.756

610 SEISMIC LOAD - Z NEGATIVE DIRECTION 124.547 -493.67 166.756

611 SEISMIC LOAD - X POSITIVE DIRECTION -109.041 325.61 -94.874

612 SEISMIC LOAD - X NEGATIVE DIRECTION 109.041 -325.61 94.874

613 SEISMIC LOAD - Y DIRECTION 0 0 0

614 POSITIVE THERMAL GRADIENT 2.799 -11.103 3.178

615 NEGATIVE THERMAL GRADIENT -2.799 11.103 -3.178

26521 601 DEAD LOAD -6.737 53.285 -18.547

602 LIVE LOAD - BRIDGE WALKWAY -0.7 7.608 -2.847

603 FLUID LOADS - OPERATING CONDITION -38.018 260.569 -86.03

604 FLUID LOADS - SANDED CONDITION -41.944 286.772 -94.596

605 LIVE LOAD - TORQUE AND LIFTING - NORMAL OPERATING -8.416 0.021 3.473

606 LIVE LOAD - TORQUE AND LIFTING - MAXIMUM -27.081 8.605 7.861

607 WIND LOAD - Z DIRECTION -13.894 60.888 -16.942

608 WIND LOAD - X DIRECTION -2.228 9.351 -3.368

609 SEISMIC LOAD - Z POSITIVE DIRECTION -91.213 572.319 -222.891

610 SEISMIC LOAD - Z NEGATIVE DIRECTION 91.213 -572.319 222.891

611 SEISMIC LOAD - X POSITIVE DIRECTION -63.988 201.07 -68.043

612 SEISMIC LOAD - X NEGATIVE DIRECTION 63.988 -201.07 68.043

613 SEISMIC LOAD - Y DIRECTION 0 0 0

614 POSITIVE THERMAL GRADIENT 1.871 -10.65 3.596

615 NEGATIVE THERMAL GRADIENT -1.871 10.65 -3.596

26524 601 DEAD LOAD -2.286 52.959 -19.615

602 LIVE LOAD - BRIDGE WALKWAY -0.215 7.45 -2.908

603 FLUID LOADS - OPERATING CONDITION -15.15 260.204 -92.945

604 FLUID LOADS - SANDED CONDITION -16.728 286.409 -102.243

605 LIVE LOAD - TORQUE AND LIFTING - NORMAL OPERATING -9.031 0.022 1.172

606 LIVE LOAD - TORQUE AND LIFTING - MAXIMUM -28.193 8.615 0.566

607 WIND LOAD - Z DIRECTION -5.043 65.206 -22.006

Page 78
Project : OCP Benguerir
Description : Foundation Load (Reactions) Data
Structure : 45m Diameter High Rate Thickeners
Doc. No. : 2689A0TR045VB101 Rev. : A
Client : OCP, Morocco

608 WIND LOAD - X DIRECTION -0.973 2.801 -1.061

609 SEISMIC LOAD - Z POSITIVE DIRECTION -34.039 611.989 -255.557

610 SEISMIC LOAD - Z NEGATIVE DIRECTION 34.039 -611.989 255.557

611 SEISMIC LOAD - X POSITIVE DIRECTION -38.347 63.009 -22.262

612 SEISMIC LOAD - X NEGATIVE DIRECTION 38.347 -63.009 22.262

613 SEISMIC LOAD - Y DIRECTION 0 0 0

614 POSITIVE THERMAL GRADIENT 0.897 -9.996 3.682

615 NEGATIVE THERMAL GRADIENT -0.897 9.996 -3.682

26527 601 DEAD LOAD 2.226 52.965 -19.613

602 LIVE LOAD - BRIDGE WALKWAY 0.226 7.456 -2.908

603 FLUID LOADS - OPERATING CONDITION 8.761 260.185 -93.717

604 FLUID LOADS - SANDED CONDITION 9.653 286.387 -103.098

605 LIVE LOAD - TORQUE AND LIFTING - NORMAL OPERATING -9.021 0.022 -1.199

606 LIVE LOAD - TORQUE AND LIFTING - MAXIMUM -27.347 8.613 -6.725

607 WIND LOAD - Z DIRECTION 5.207 65.005 -21.862

608 WIND LOAD - X DIRECTION -1.026 -3.741 1.515

609 SEISMIC LOAD - Z POSITIVE DIRECTION 32.191 609.857 -254.505

610 SEISMIC LOAD - Z NEGATIVE DIRECTION -32.191 -609.857 254.505

611 SEISMIC LOAD - X POSITIVE DIRECTION -38.902 -79.4 30.497

612 SEISMIC LOAD - X NEGATIVE DIRECTION 38.902 79.4 -30.497

613 SEISMIC LOAD - Y DIRECTION 0 0 0

614 POSITIVE THERMAL GRADIENT 0 -9.203 3.458

615 NEGATIVE THERMAL GRADIENT 0 9.203 -3.458

26530 601 DEAD LOAD 6.709 53.317 -18.565

602 LIVE LOAD - BRIDGE WALKWAY 0.716 7.629 -2.848

603 FLUID LOADS - OPERATING CONDITION 32.183 260.596 -88.424

604 FLUID LOADS - SANDED CONDITION 35.482 286.8 -97.246

605 LIVE LOAD - TORQUE AND LIFTING - NORMAL OPERATING -8.41 0.021 -3.489

606 LIVE LOAD - TORQUE AND LIFTING - MAXIMUM -24.686 8.606 -13.557

Page 79
Project : OCP Benguerir
Description : Foundation Load (Reactions) Data
Structure : 45m Diameter High Rate Thickeners
Doc. No. : 2689A0TR045VB101 Rev. : A
Client : OCP, Morocco

607 WIND LOAD - Z DIRECTION 14.015 60.325 -16.625

608 WIND LOAD - X DIRECTION -2.337 -9.839 3.661

609 SEISMIC LOAD - Z POSITIVE DIRECTION 89.029 566.266 -220.576

610 SEISMIC LOAD - Z NEGATIVE DIRECTION -89.029 -566.266 220.576

611 SEISMIC LOAD - X POSITIVE DIRECTION -65.977 -216.384 75.75

612 SEISMIC LOAD - X NEGATIVE DIRECTION 65.977 216.384 -75.75

613 SEISMIC LOAD - Y DIRECTION 0 0 0

614 POSITIVE THERMAL GRADIENT -0.724 -8.356 3.013

615 NEGATIVE THERMAL GRADIENT 0.724 8.356 -3.013

26533 601 DEAD LOAD 10.991 53.911 -16.405

602 LIVE LOAD - BRIDGE WALKWAY 1.3 7.917 -2.646

603 FLUID LOADS - OPERATING CONDITION 53.523 261.283 -77.444

604 FLUID LOADS - SANDED CONDITION 58.978 287.488 -85.127

605 LIVE LOAD - TORQUE AND LIFTING - NORMAL OPERATING -7.213 0.02 -5.55

606 LIVE LOAD - TORQUE AND LIFTING - MAXIMUM -20.313 8.595 -19.496

607 WIND LOAD - Z DIRECTION 18.969 51.521 -7.746

608 WIND LOAD - X DIRECTION -4.47 -15.11 4.831

609 SEISMIC LOAD - Z POSITIVE DIRECTION 120.958 484.041 -163.295

610 SEISMIC LOAD - Z NEGATIVE DIRECTION -120.958 -484.041 163.295

611 SEISMIC LOAD - X POSITIVE DIRECTION -111.421 -338.668 101.4

612 SEISMIC LOAD - X NEGATIVE DIRECTION 111.421 338.668 -101.4

613 SEISMIC LOAD - Y DIRECTION 0 0 0

614 POSITIVE THERMAL GRADIENT -1.239 -7.53 2.455

615 NEGATIVE THERMAL GRADIENT 1.239 7.53 -2.455

26536 601 DEAD LOAD 14.872 54.58 -12.97

602 LIVE LOAD - BRIDGE WALKWAY 1.946 8.235 -2.18

603 FLUID LOADS - OPERATING CONDITION 71.789 262.068 -60.987

604 FLUID LOADS - SANDED CONDITION 79.052 288.274 -67.003

605 LIVE LOAD - TORQUE AND LIFTING - NORMAL OPERATING -5.529 0.02 -7.232

Page 80
Project : OCP Benguerir
Description : Foundation Load (Reactions) Data
Structure : 45m Diameter High Rate Thickeners
Doc. No. : 2689A0TR045VB101 Rev. : A
Client : OCP, Morocco

606 LIVE LOAD - TORQUE AND LIFTING - MAXIMUM -14.567 8.582 -24.105

607 WIND LOAD - Z DIRECTION 18.872 39.29 2.357

608 WIND LOAD - X DIRECTION -6.894 -19.265 4.78

609 SEISMIC LOAD - Z POSITIVE DIRECTION 120.324 368.944 -97.778

610 SEISMIC LOAD - Z NEGATIVE DIRECTION -120.324 -368.944 97.778

611 SEISMIC LOAD - X POSITIVE DIRECTION -164.208 -437.91 100.992

612 SEISMIC LOAD - X NEGATIVE DIRECTION 164.208 437.91 -100.992

613 SEISMIC LOAD - Y DIRECTION 0 0 0

614 POSITIVE THERMAL GRADIENT -1.567 -6.792 1.853

615 NEGATIVE THERMAL GRADIENT 1.567 6.792 -1.853

26539 601 DEAD LOAD 17.836 55.126 -8.284

602 LIVE LOAD - BRIDGE WALKWAY 2.501 8.485 -1.393

603 FLUID LOADS - OPERATING CONDITION 85.241 262.686 -39.797

604 FLUID LOADS - SANDED CONDITION 93.811 288.889 -43.715

605 LIVE LOAD - TORQUE AND LIFTING - NORMAL OPERATING -3.472 0.017 -8.409

606 LIVE LOAD - TORQUE AND LIFTING - MAXIMUM -7.845 8.565 -27.029

607 WIND LOAD - Z DIRECTION 13.715 24.518 11.059

608 WIND LOAD - X DIRECTION -8.947 -22.107 3.517

609 SEISMIC LOAD - Z POSITIVE DIRECTION 86.574 228.562 -40.772

610 SEISMIC LOAD - Z NEGATIVE DIRECTION -86.574 -228.562 40.772

611 SEISMIC LOAD - X POSITIVE DIRECTION -209.541 -507.354 73.802

612 SEISMIC LOAD - X NEGATIVE DIRECTION 209.541 507.354 -73.802

613 SEISMIC LOAD - Y DIRECTION 0 0 0

614 POSITIVE THERMAL GRADIENT -1.738 -6.183 1.256

615 NEGATIVE THERMAL GRADIENT 1.738 6.183 -1.256

26542 601 DEAD LOAD 19.423 55.404 -2.727

602 LIVE LOAD - BRIDGE WALKWAY 2.794 8.587 -0.358

603 FLUID LOADS - OPERATING CONDITION 92.68 263.047 -15.565

604 FLUID LOADS - SANDED CONDITION 101.97 289.251 -17.12

Page 81
Project : OCP Benguerir
Description : Foundation Load (Reactions) Data
Structure : 45m Diameter High Rate Thickeners
Doc. No. : 2689A0TR045VB101 Rev. : A
Client : OCP, Morocco

605 LIVE LOAD - TORQUE AND LIFTING - NORMAL OPERATING -1.185 0.015 -9.026

606 LIVE LOAD - TORQUE AND LIFTING - MAXIMUM -0.607 8.553 -28.16

607 WIND LOAD - Z DIRECTION 4.968 8.279 15.987

608 WIND LOAD - X DIRECTION -10.118 -23.521 1.407

609 SEISMIC LOAD - Z POSITIVE DIRECTION 28.905 72.676 -8.514

610 SEISMIC LOAD - Z NEGATIVE DIRECTION -28.905 -72.676 8.514

611 SEISMIC LOAD - X POSITIVE DIRECTION -235.302 -542.374 27.484

612 SEISMIC LOAD - X NEGATIVE DIRECTION 235.302 542.374 -27.484

613 SEISMIC LOAD - Y DIRECTION 0 0 0

614 POSITIVE THERMAL GRADIENT -1.79 -5.73 0.693

615 NEGATIVE THERMAL GRADIENT 1.79 5.73 -0.693

26545 601 DEAD LOAD 19.357 55.315 3.058

602 LIVE LOAD - BRIDGE WALKWAY 2.718 8.494 0.738

603 FLUID LOADS - OPERATING CONDITION 93.484 262.994 9.549

604 FLUID LOADS - SANDED CONDITION 102.865 289.199 10.432

605 LIVE LOAD - TORQUE AND LIFTING - NORMAL OPERATING 1.198 0.014 -9.021

606 LIVE LOAD - TORQUE AND LIFTING - MAXIMUM 6.725 8.548 -27.362

607 WIND LOAD - Z DIRECTION -4.98 -8.323 15.899

608 WIND LOAD - X DIRECTION -10.117 -23.45 -0.98

609 SEISMIC LOAD - Z POSITIVE DIRECTION -36.718 -88.189 -9.156

610 SEISMIC LOAD - Z NEGATIVE DIRECTION 36.718 88.189 9.156

611 SEISMIC LOAD - X POSITIVE DIRECTION -234.59 -540.481 -24.814

612 SEISMIC LOAD - X NEGATIVE DIRECTION 234.59 540.481 24.814

613 SEISMIC LOAD - Y DIRECTION 0 0 0

614 POSITIVE THERMAL GRADIENT -1.752 -5.431 0.168

615 NEGATIVE THERMAL GRADIENT 1.752 5.431 -0.168

26548 601 DEAD LOAD 17.682 54.863 8.523

602 LIVE LOAD - BRIDGE WALKWAY 2.302 8.214 1.696

603 FLUID LOADS - OPERATING CONDITION 87.651 262.549 34.066

Page 82
Project : OCP Benguerir
Description : Foundation Load (Reactions) Data
Structure : 45m Diameter High Rate Thickeners
Doc. No. : 2689A0TR045VB101 Rev. : A
Client : OCP, Morocco

604 FLUID LOADS - SANDED CONDITION 96.493 288.756 37.348

605 LIVE LOAD - TORQUE AND LIFTING - NORMAL OPERATING 3.497 0.012 -8.405

606 LIVE LOAD - TORQUE AND LIFTING - MAXIMUM 13.598 8.55 -24.701

607 WIND LOAD - Z DIRECTION -13.534 -24.138 10.861

608 WIND LOAD - X DIRECTION -8.966 -21.9 -3.085

609 SEISMIC LOAD - Z POSITIVE DIRECTION -93.515 -242.958 -42.813

610 SEISMIC LOAD - Z NEGATIVE DIRECTION 93.515 242.958 42.813

611 SEISMIC LOAD - X POSITIVE DIRECTION -208.219 -501.926 -70.17

612 SEISMIC LOAD - X NEGATIVE DIRECTION 208.219 501.926 70.17

613 SEISMIC LOAD - Y DIRECTION 0 0 0

614 POSITIVE THERMAL GRADIENT -1.632 -5.278 -0.333

615 NEGATIVE THERMAL GRADIENT 1.632 5.278 0.333

26551 601 DEAD LOAD 14.637 54.146 13.075

602 LIVE LOAD - BRIDGE WALKWAY 1.67 7.802 2.352

603 FLUID LOADS - OPERATING CONDITION 75.486 261.771 55.942

604 FLUID LOADS - SANDED CONDITION 83.163 287.975 61.406

605 LIVE LOAD - TORQUE AND LIFTING - NORMAL OPERATING 5.545 0.01 -7.213

606 LIVE LOAD - TORQUE AND LIFTING - MAXIMUM 19.502 8.552 -20.342

607 WIND LOAD - Z DIRECTION -18.379 -38.127 2.284

608 WIND LOAD - X DIRECTION -6.889 -18.922 -4.355

609 SEISMIC LOAD - Z POSITIVE DIRECTION -125.769 -381.237 -100.408

610 SEISMIC LOAD - Z NEGATIVE DIRECTION 125.769 381.237 100.408

611 SEISMIC LOAD - X POSITIVE DIRECTION -161.963 -429.134 -96.209

612 SEISMIC LOAD - X NEGATIVE DIRECTION 161.963 429.134 96.209

613 SEISMIC LOAD - Y DIRECTION 0 0 0

614 POSITIVE THERMAL GRADIENT -1.426 -5.259 -0.807

615 NEGATIVE THERMAL GRADIENT 1.426 5.259 0.807

26554 601 DEAD LOAD 10.757 53.35 16.395

602 LIVE LOAD - BRIDGE WALKWAY 1.023 7.352 2.672

Page 83
Project : OCP Benguerir
Description : Foundation Load (Reactions) Data
Structure : 45m Diameter High Rate Thickeners
Doc. No. : 2689A0TR045VB101 Rev. : A
Client : OCP, Morocco

603 FLUID LOADS - OPERATING CONDITION 58.345 260.926 73.592

604 FLUID LOADS - SANDED CONDITION 64.335 287.131 80.86

605 LIVE LOAD - TORQUE AND LIFTING - NORMAL OPERATING 7.224 0.009 -5.542

606 LIVE LOAD - TORQUE AND LIFTING - MAXIMUM 24.103 8.558 -14.629

607 WIND LOAD - Z DIRECTION -18.306 -49.398 -7.507

608 WIND LOAD - X DIRECTION -4.444 -14.651 -4.425

609 SEISMIC LOAD - Z POSITIVE DIRECTION -124.774 -493.572 -166.528

610 SEISMIC LOAD - Z NEGATIVE DIRECTION 124.774 493.572 166.528

611 SEISMIC LOAD - X POSITIVE DIRECTION -109.128 -327.258 -95.59

612 SEISMIC LOAD - X NEGATIVE DIRECTION 109.128 327.258 95.59

613 SEISMIC LOAD - Y DIRECTION 0 0 0

614 POSITIVE THERMAL GRADIENT -1.134 -5.368 -1.244

615 NEGATIVE THERMAL GRADIENT 1.134 5.368 1.244

26557 601 DEAD LOAD 6.565 52.664 18.454

602 LIVE LOAD - BRIDGE WALKWAY 0.515 6.97 2.749

603 FLUID LOADS - OPERATING CONDITION 37.909 260.187 85.977

604 FLUID LOADS - SANDED CONDITION 41.834 286.393 94.544

605 LIVE LOAD - TORQUE AND LIFTING - NORMAL OPERATING 8.413 0.008 -3.475

606 LIVE LOAD - TORQUE AND LIFTING - MAXIMUM 27.07 8.566 -7.868

607 WIND LOAD - Z DIRECTION -13.435 -57.263 -15.862

608 WIND LOAD - X DIRECTION -2.274 -9.286 -3.251

609 SEISMIC LOAD - Z POSITIVE DIRECTION -91.487 -572.249 -222.744

610 SEISMIC LOAD - Z NEGATIVE DIRECTION 91.487 572.249 222.744

611 SEISMIC LOAD - X POSITIVE DIRECTION -64.049 -203.121 -68.919

612 SEISMIC LOAD - X NEGATIVE DIRECTION 64.049 203.121 68.919

613 SEISMIC LOAD - Y DIRECTION 0 0 0

614 POSITIVE THERMAL GRADIENT -0.759 -5.609 -1.635

615 NEGATIVE THERMAL GRADIENT 0.759 5.609 1.635

26560 601 DEAD LOAD 2.241 52.264 19.442

Page 84
Project : OCP Benguerir
Description : Foundation Load (Reactions) Data
Structure : 45m Diameter High Rate Thickeners
Doc. No. : 2689A0TR045VB101 Rev. : A
Client : OCP, Morocco

602 LIVE LOAD - BRIDGE WALKWAY 0.159 6.747 2.732

603 FLUID LOADS - OPERATING CONDITION 15.12 259.767 92.837

604 FLUID LOADS - SANDED CONDITION 16.697 285.973 102.135

605 LIVE LOAD - TORQUE AND LIFTING - NORMAL OPERATING 9.029 0.009 -1.175

606 LIVE LOAD - TORQUE AND LIFTING - MAXIMUM 28.189 8.573 -0.578

607 WIND LOAD - Z DIRECTION -5.059 -61.265 -20.744

608 WIND LOAD - X DIRECTION -0.955 -3.133 -1.099

609 SEISMIC LOAD - Z POSITIVE DIRECTION -34.339 -611.966 -255.507

610 SEISMIC LOAD - Z NEGATIVE DIRECTION 34.339 611.966 255.507

611 SEISMIC LOAD - X POSITIVE DIRECTION -38.359 -65.302 -23.231

612 SEISMIC LOAD - X NEGATIVE DIRECTION 38.359 65.302 23.231

613 SEISMIC LOAD - Y DIRECTION 0 0 0

614 POSITIVE THERMAL GRADIENT -0.282 -5.99 -1.969

615 NEGATIVE THERMAL GRADIENT 0.282 5.99 1.969

26563 601 DEAD LOAD -2.12 52.244 19.435

602 LIVE LOAD - BRIDGE WALKWAY -0.131 6.736 2.729

603 FLUID LOADS - OPERATING CONDITION -8.694 259.721 93.602

604 FLUID LOADS - SANDED CONDITION -9.588 285.924 102.983

605 LIVE LOAD - TORQUE AND LIFTING - NORMAL OPERATING 9.022 0.008 1.195

606 LIVE LOAD - TORQUE AND LIFTING - MAXIMUM 27.351 8.571 6.714

607 WIND LOAD - Z DIRECTION 4.648 -61.161 -20.713

608 WIND LOAD - X DIRECTION -0.881 3.431 1.505

609 SEISMIC LOAD - Z POSITIVE DIRECTION 31.892 -609.89 -254.558

610 SEISMIC LOAD - Z NEGATIVE DIRECTION -31.892 609.89 254.558

611 SEISMIC LOAD - X POSITIVE DIRECTION -38.849 77.067 29.523

612 SEISMIC LOAD - X NEGATIVE DIRECTION 38.849 -77.067 -29.523

613 SEISMIC LOAD - Y DIRECTION 0 0 0

614 POSITIVE THERMAL GRADIENT 0.302 -6.515 -2.217

615 NEGATIVE THERMAL GRADIENT -0.302 6.515 2.217

Page 85
Project : OCP Benguerir
Description : Foundation Load (Reactions) Data
Structure : 45m Diameter High Rate Thickeners
Doc. No. : 2689A0TR045VB101 Rev. : A
Client : OCP, Morocco

26566 601 DEAD LOAD -6.469 52.618 18.459

602 LIVE LOAD - BRIDGE WALKWAY -0.488 6.941 2.742

603 FLUID LOADS - OPERATING CONDITION -32.029 260.137 88.352

604 FLUID LOADS - SANDED CONDITION -35.328 286.341 97.173

605 LIVE LOAD - TORQUE AND LIFTING - NORMAL OPERATING 8.414 0.008 3.487

606 LIVE LOAD - TORQUE AND LIFTING - MAXIMUM 24.697 8.567 13.549

607 WIND LOAD - Z DIRECTION 13.05 -56.967 -15.856

608 WIND LOAD - X DIRECTION -2.149 9.961 3.848

609 SEISMIC LOAD - Z POSITIVE DIRECTION 88.756 -566.346 -220.727

610 SEISMIC LOAD - Z NEGATIVE DIRECTION -88.756 566.346 220.727

611 SEISMIC LOAD - X POSITIVE DIRECTION -65.858 214.223 74.864

612 SEISMIC LOAD - X NEGATIVE DIRECTION 65.858 -214.223 -74.864

613 SEISMIC LOAD - Y DIRECTION 0 0 0

614 POSITIVE THERMAL GRADIENT 0.994 -7.179 -2.337

615 NEGATIVE THERMAL GRADIENT -0.994 7.179 2.337

26569 601 DEAD LOAD -10.672 53.286 16.429

602 LIVE LOAD - BRIDGE WALKWAY -0.995 7.31 2.67

603 FLUID LOADS - OPERATING CONDITION -53.315 260.862 77.452

604 FLUID LOADS - SANDED CONDITION -58.771 287.067 85.134

605 LIVE LOAD - TORQUE AND LIFTING - NORMAL OPERATING 7.218 0.01 5.55

606 LIVE LOAD - TORQUE AND LIFTING - MAXIMUM 20.328 8.562 19.495

607 WIND LOAD - Z DIRECTION 17.864 -48.898 -7.469

608 WIND LOAD - X DIRECTION -4.434 16.012 5.287

609 SEISMIC LOAD - Z POSITIVE DIRECTION 120.735 -484.152 -163.527

610 SEISMIC LOAD - Z NEGATIVE DIRECTION -120.735 484.152 163.527

611 SEISMIC LOAD - X POSITIVE DIRECTION -111.258 336.872 100.688

612 SEISMIC LOAD - X NEGATIVE DIRECTION 111.258 -336.872 -100.688

613 SEISMIC LOAD - Y DIRECTION 0 0 0

614 POSITIVE THERMAL GRADIENT 1.763 -7.954 -2.28

Page 86
Project : OCP Benguerir
Description : Foundation Load (Reactions) Data
Structure : 45m Diameter High Rate Thickeners
Doc. No. : 2689A0TR045VB101 Rev. : A
Client : OCP, Morocco

615 NEGATIVE THERMAL GRADIENT -1.763 7.954 2.28

26572 601 DEAD LOAD -14.548 54.073 13.145

602 LIVE LOAD - BRIDGE WALKWAY -1.638 7.753 2.355

603 FLUID LOADS - OPERATING CONDITION -71.574 261.715 61.091

604 FLUID LOADS - SANDED CONDITION -78.837 287.921 67.106

605 LIVE LOAD - TORQUE AND LIFTING - NORMAL OPERATING 5.534 0.011 7.235

606 LIVE LOAD - TORQUE AND LIFTING - MAXIMUM 14.582 8.556 24.112

607 WIND LOAD - Z DIRECTION 17.882 -37.434 2.225

608 WIND LOAD - X DIRECTION -7.207 21.109 5.403

609 SEISMIC LOAD - Z POSITIVE DIRECTION 120.163 -369.058 -98.068

610 SEISMIC LOAD - Z NEGATIVE DIRECTION -120.163 369.058 98.068

611 SEISMIC LOAD - X POSITIVE DIRECTION -164.043 436.598 100.511

612 SEISMIC LOAD - X NEGATIVE DIRECTION 164.043 -436.598 -100.511

613 SEISMIC LOAD - Y DIRECTION 0 0 0

614 POSITIVE THERMAL GRADIENT 2.568 -8.786 -1.982

615 NEGATIVE THERMAL GRADIENT -2.568 8.786 1.982

26575 601 DEAD LOAD -17.587 54.774 8.592

602 LIVE LOAD - BRIDGE WALKWAY -2.268 8.16 1.7

603 FLUID LOADS - OPERATING CONDITION -85.069 262.427 39.989

604 FLUID LOADS - SANDED CONDITION -93.639 288.629 43.906

605 LIVE LOAD - TORQUE AND LIFTING - NORMAL OPERATING 3.476 0.012 8.413

606 LIVE LOAD - TORQUE AND LIFTING - MAXIMUM 7.856 8.549 27.043

607 WIND LOAD - Z DIRECTION 12.961 -23.244 10.727

608 WIND LOAD - X DIRECTION -9.676 24.792 4.073

609 SEISMIC LOAD - Z POSITIVE DIRECTION 86.479 -228.65 -41.097

610 SEISMIC LOAD - Z NEGATIVE DIRECTION -86.479 228.65 41.097

611 SEISMIC LOAD - X POSITIVE DIRECTION -209.42 506.517 73.559

612 SEISMIC LOAD - X NEGATIVE DIRECTION 209.42 -506.517 -73.559

613 SEISMIC LOAD - Y DIRECTION 0 0 0

Page 87
Project : OCP Benguerir
Description : Foundation Load (Reactions) Data
Structure : 45m Diameter High Rate Thickeners
Doc. No. : 2689A0TR045VB101 Rev. : A
Client : OCP, Morocco

614 POSITIVE THERMAL GRADIENT 3.305 -9.604 -1.407

615 NEGATIVE THERMAL GRADIENT -3.305 9.604 1.407

26578 601 DEAD LOAD -19.304 55.23 3.114

602 LIVE LOAD - BRIDGE WALKWAY -2.691 8.442 0.742

603 FLUID LOADS - OPERATING CONDITION -92.589 262.899 15.811

604 FLUID LOADS - SANDED CONDITION -101.878 289.101 17.365

605 LIVE LOAD - TORQUE AND LIFTING - NORMAL OPERATING 1.186 0.013 9.032

606 LIVE LOAD - TORQUE AND LIFTING - MAXIMUM 0.611 8.547 28.178

607 WIND LOAD - Z DIRECTION 4.397 -7.26 15.656

608 WIND LOAD - X DIRECTION -11.128 26.692 1.659

609 SEISMIC LOAD - Z POSITIVE DIRECTION 28.876 -72.715 -8.854

610 SEISMIC LOAD - Z NEGATIVE DIRECTION -28.876 72.715 8.854

611 SEISMIC LOAD - X POSITIVE DIRECTION -235.236 541.848 27.444

612 SEISMIC LOAD - X NEGATIVE DIRECTION 235.236 -541.848 -27.444

613 SEISMIC LOAD - Y DIRECTION 0 0 0

614 POSITIVE THERMAL GRADIENT 3.856 -10.333 -0.577

615 NEGATIVE THERMAL GRADIENT -3.856 10.333 0.577

Page 88