Note MPPT Range for Full Load (V) from Inverter Technical details and take
Section 690-7 of the NEC establishes a temperature-dependent voltage correction factor that is to be
applied to the Open Circuit Voltage 𝑈𝑂𝐶 (V) in order to establish the system voltage. This factor on the
Open Circuit Voltage 𝑈𝑂𝐶 (V) is needed because, as the operating temperature of the module decreases,
Open Circuit Voltage 𝑈𝑂𝐶 (V) increases. The rated Open Circuit Voltage 𝑈𝑂𝐶 (V) is measured at a
temperature of 25°C.
An extreme minimum temperature of −4.0 °C (24.8 °F) was recorded on 15 January 1978 so
multiplicative factor from table we got is 1.12.
Note MPPT Range for Full Load (V) from Inverter Technical details and take
850𝑉
Maximum Number of Panels in a String = = 15.42 ≅ 15
55.104𝑉
MPPT Range for Full Load (V) = 𝑀𝑎𝑥𝑖𝑚𝑢𝑚 𝑁𝑢𝑚𝑏𝑒𝑟 𝑜𝑓 𝑃𝑎𝑛𝑒𝑙𝑠 𝑖𝑛 𝑎 𝑆𝑡𝑟𝑖𝑛𝑔 ×
𝑀𝑎𝑥𝑖𝑚𝑢𝑚 𝑃𝑜𝑤𝑒𝑟 𝑉𝑜𝑙𝑡𝑎𝑔𝑒 𝑈𝑀𝑃𝑃 (𝑉)
MPPT Range for Full Load (V) = 15 × 40.5𝑉 = 𝟔𝟎𝟕. 𝟓𝑽 which is within 520V-850V
Range.
Now Calculate the MPPT Full Load Voltage by Multiplying
𝑼𝑶𝑪 𝒂𝒇𝒕𝒆𝒓 𝑻𝒆𝒎𝒑 𝑰𝒎𝒑𝒂𝒄𝒕 × 𝑀𝑎𝑥𝑖𝑚𝑢𝑚 𝑁𝑢𝑚𝑏𝑒𝑟 𝑜𝑓 𝑃𝑎𝑛𝑒𝑙𝑠 𝑖𝑛 𝑎 𝑆𝑡𝑟𝑖𝑛𝑔 𝐶𝑎𝑙𝑐𝑢𝑙𝑎𝑡𝑒𝑑 𝑖𝑛 𝑠𝑡𝑒𝑝 2