Location via proxy:   [ UP ]  
[Report a bug]   [Manage cookies]                

40LM 120,150,200 - PRODUCT DATA DIGEST: The World Leading Air-Conditioning Company

Download as pdf or txt
Download as pdf or txt
You are on page 1of 14

40LM 120,150,200 – PRODUCT DATA DIGEST

The World Leading Air-conditioning Company


TABLE OF CONTENS

DESCRIPTIONS PAGE
FEATURES & SPECIFICATIONS 2

PYSICAL DIMENSION - UNIT SIZE 40LM 120 3

PHYSICAL DIMENSION - UNIT SIZE 40LM 150,200 4

PERFORMANCE DATA COOLING CAPACITIES 5~7


40LM 120
40LM 150
40LM 200
PERFORMANCE DATA COIL PRESSURE DROP 8
40LM 120
40LM 150
40LM 200
FAN PERFORMANCE 9
40LM 120
40LM 150
40LM 200
SOUND PRESSURE LEVEL DATA 10

FAN MOTOR AND DRIVES 11

GUIDE SPECIFICATIONS 12
FEATURES & SPECIFICATIONS

The New, Versatile and Flexibility in Commercial Air Conditioning


System
 Chilled Water Furred-in model with Plenum Fan Coil units.

 The low silhouette styling of this unit makes it a popular choice for the “in-the-ceiling” or “over the closet”
applications in all types of building.

 Horizontal ducted application. The 40LM 150 & 200 can easily be converted to vertical ducted application.

 Insulated & painted condensate drain pan and a factory fitted frame complete with filter media. (Filter media is
optional for 40LM150 & 200).

 Integral filter frame capable of adapting 1” or 2” filter media for 40LM 150 & 200.

 40LM 120 is standard factory supplied with 3-speed direct drive motor.

 40LM 150 & 200 is standard factory supplied with TEFC Induction motor and taper lock pulleys with wedge belts.

 Standard copper tube aluminum fins (Cu/Al) evaporator coil for maximum heat transfer.

 Carrier Lanced Sine Wave fin pattern ensures energy efficient performance.

 Units piping connection as below:


a) 40LM 120  LHS
b) 40LM 150~200  RHS (Vertical)
LHS (Horizontal)
.
TYPE CHILLED WATER FAN COIL
MODEL 40LM120 40LM150 40LM200
kW 34.8 44 58.6
NOMINAL CAPACITY
Btu/hr 119 000 150 000 199 940
AIR QUANTITY Range (l/s) 1280 - 1753 421 - 659 2000 ~ 3400
POWER SUPPLY V/Ph/Hz 230/1/50 380 ~ 415/3/50 380 ~ 415/3/50
Type Centrifugal Forward Curved Blades
Drive Direct Drive Belt Drive Belt Drive
FAN Quantity pcs 2 1 1
Max Rev rpm 150 1200 1200
Diameter mm 241 400 400
Type PSC, 3 Speeds TEFC TEFC
Quantity pcs 1 1 1
FAN MOTOR Power Input kW 1.41 2.2 3
Full Load Amps A 7.4 5.08 @ 380V 6.72 @ 380V
Rev rpm 1405 1500 1500
Type Copper Tube, Aluminium Plate Fins
COIL Row - Fins/in 4 - 14 4 - 12 4 - 12
2
Face Area m 0.61 1.01 1.36
Type Washable / Throw Away
FILTER Size (H x W x D) mm 398 x 1344 x 12 406 x 635 x 25 406 x 635/508 x 25
Quantity pcs 1 4 2& 4
Supply Inch 25.4 BSP MPT 38.1 BSP MPT 50.8 BSP MPT
CONNECTIONS Return Inch 25.4 BSP MPT 38.1 BSP MPT 50.8 BSP MPT
Drain Pipe Inch 19.05 NPT MPT 19.05 NPT MPT 19.05 NPT MPT
NET WEIGHT Kg 117 200 200
Height mm 480 1487 1541
DIMENSIONS Width mm 1600 1346 1651
Length mm 680 710 764
FLA: FULL LOAD AMPS FPI: FINS PER INCH

2
PHYSICAL DIMENSION – UNIT SIZE 40LM 120

3
PHYSICAL DIMENSION – UNIT SIZE 40LM 150,200

Model No A B C D E F G H J K L

40LM 150 1346 1487 644 208 1413 553 660 1270 1161 224 1.5

40LM 200 1651 1541 698 235 1713 606 714 1575 1215 276 2.0

28.6 DIA HOLE

FOR ELECTRICAL CONNECTION


E

CONTROL BOX AREA

65.6
D

450.0

450.0 C

31.6
54.1 H

28.6 DIA KNOCOUT


MOUNTING (4PLCS)

WATER OUT
“L” INCH BSP GRADE B

J B

348.9

49.6
A
FILTER SECTION AREA
22.2
WATER IN “L” INCH 3/4” NPT
BPS GRADE B DRAIN CONN. (4PLCS)
(MPT)

4
PERFORMANCE DATA COOLING CAPACITIES

MODEL: 40LM 120


Ent
Air Chilled Ent Air Temperature DB/WB (°C)
Chilled
Water
Quantity Water Flow 25.0 / 17.0 27.0/ 19.5 29.0 / 22.0
Temp
(l/s) (°C) (l/min) TC SHC TC SHC TC SHC
45 20.3 17 24.7 17.6 29.9 18.2
5 90 23.8 18.7 30 19.9 36.7 21
135 25.4 19.4 32.1 20.8 39.4 22.2
45 18.9 16.3 23.3 17 28.2 17.6
6 90 22.2 17.9 28.1 19.1 34.9 20.2
135 23.4 18.5 30.2 20 37.4 21.3
45 17.6 15.7 21.8 16.4 26.6 16.9
1000 7 90 20.4 17.1 26.3 18.3 32.9 19.4
135 21.6 17.7 28.2 19.1 35.4 20.4
45 16.3 15.1 20.3 15.7 25.1 16.3
8 90 18.7 16.3 24.4 17.5 31 18.6
135 19.8 16.8 26.2 18.2 33.4 19.6
45 15 14.4 18.8 15.1 23.5 15.7
9 90 17 15.5 22.5 16.7 29 17.8
135 17.9 16 24.1 17.4 31.3 18.7
45 22.9 20.1 27.5 20.7 32.7 21.1
5 90 27.5 22.5 34.3 23.7 41.9 24.7
135 29.6 23.5 37.4 25 45.8 26.4
45 21.4 19.4 25.8 20 31 20.4
6 90 25.6 21.6 32.1 22.8 39.7 23.8
135 27.5 22.5 35.1 24 43.5 25.4
45 20 18.7 24.3 19.3 29.3 19.8
1300 7 90 23.6 20.6 30 21.8 37.5 23
135 25.4 21.5 32.8 23 41.1 24.4
45 18.6 17.9 22.7 18.6 27.6 19.1
8 90 21.8 19.7 27.8 20.9 35.2 22.1
135 23.2 20.5 30.4 22 38.7 23.4
45 17.3 17.1 21.1 18 25.9 18.5
9 90 19.9 18.9 25.8 20.1 32.9 21.2
135 21.1 19.5 27.9 21 36.2 22.4
45 26.2 24.6 30.8 25.2 36.1 25.4
5 90 32.2 28 39.5 29.1 48.1 30.1
135 35.4 29.6 44.2 31.1 54 32.4
45 24.7 23.7 29.1 24.4 34.2 24.7
6 90 30.1 26.9 37.2 28.1 45.5 29.1
135 32.8 28.4 41.4 29.9 51.1 31.2
45 23.3 22.8 27.4 23.7 32.4 24
1820 7 90 28.1 25.9 34.8 27.1 42.9 28.1
135 30.3 27.1 38.5 28.7 48.3 30.1
45 21.8 21.8 25.8 22.9 30.6 23.3
8 90 25.9 24.8 32.4 26.1 40.1 27
135 28 26 35.8 27.5 45.3 29
45 20.5 20.5 24 22.1 28.7 22.5
9 90 24 23.6 30 25.1 37.6 26.1
135 25.6 24.7 33.1 26.4 42.4 27.9

5
PERFORMANCE DATA COOLING CAPACITIES

MODEL: 40LM 150


Air Ent Chilled Chilled Ent Air Temperature DB/WB (°C)

Water Water
Quantity 25.0 / 17.0 27.0/ 19.5 29.0 / 22.0
Temp Flow
(l/s) (°C) (l/min) TC SHC TC SHC TC SHC
55 29.4 26 35 26.6 41.5 27.1
5 110 35.8 29.2 44.4 30.6 54.2 32
165 38.8 30.3 48.9 32.6 59.9 34.4
55 27.6 25.1 33.1 25.8 39.4 26.2
6 110 33.3 28.1 41.6 29.5 51.3 30.9
165 36.1 29.4 45.9 31.3 56.8 33.1
55 25.8 24.2 31 24.9 37.3 25.4
1700 7 110 30.8 26.9 38.9 28.4 48.5 29.7
165 33.3 28.1 42.8 29.9 53.7 31.8
55 24.1 23.2 29.1 24.1 35.1 24.6
8 110 28.6 25.9 36.2 27.2 45.5 28.6
165 30.4 26.8 39.7 28.7 50.5 30.5
55 22.5 22.2 27.1 23.2 33.1 23.9
9 110 26.1 24.6 33.5 26.1 42.5 27.4
165 27.8 25.6 36.6 27.4 47.3 29.2
55 32.4 29.9 37.9 30.6 44.5 30.8
5 110 40.1 34.2 49.1 35.5 59.8 36.7
165 44.1 36.1 55 37.9 67.2 39.7
55 30.5 28.9 35.9 29.6 42.3 29.9
6 110 37.4 32.9 46.2 34.2 56.6 35.4
165 41 34.6 51.6 36.5 63.7 38.2
55 28.7 27.8 33.9 28.8 39.9 29.1
2100 7 110 34.9 31.6 43.3 33 53.3 34.2
165 37.8 33.2 48.1 35 60.2 36.8
55 26.9 26.7 31.8 27.8 37.7 28.2
8 110 32.2 30.3 40.3 31.8 50 33
165 34.9 31.7 44.7 33.6 56.6 35.4
55 25.3 25.3 29.7 26.8 35.5 27.4
9 110 29.8 28.9 37.3 30.5 46.7 31.8
165 31.9 30.3 41.3 32.2 52.9 34
55 35 33.3 40.4 33.9 46.8 34.1
5 110 43.7 38.5 53 39.7 63.8 40.8
165 48.4 40.8 59.9 42.6 73 44.3
55 32.9 31.9 38.2 32.9 44.4 33.2
6 110 40.9 37 49.9 38.4 60.4 39.5
165 44.9 39.2 56.1 41.1 69.2 42.7
55 31 30.8 36 32 42.1 32.3
2600 7 110 38.1 35.7 46.7 37.1 56.9 38.2
165 41.7 37.7 52.3 39.5 65.2 41.2
55 29.3 29.3 33.9 30.9 39.8 31.4
8 110 35.5 34.2 43.5 35.8 53.5 36.8
165 38.6 36.1 48.7 38 61.3 39.8
55 27.6 27.6 31.9 29.8 37.6 30.4
9 110 32.9 32.6 40.4 34.4 50.1 35.6
165 35.5 34.4 45.1 36.5 57.3 38.3

6
PERFORMANCE DATA COOLING CAPACITIES

MODEL: 40LM 200


Air Ent Chilled Chilled Ent Air Temperature DB/WB (°C)

Water Water
Quantity 25.0 / 17.0 27.0/ 19.5 29.0 / 22.0
Temp Flow
(l/s) (°C) (l/min) TC SHC TC SHC TC SHC
73 37.8 32.3 45.6 33.3 54.3 34
5 145 45.2 35.9 56.5 38 69.1 40
218 48.6 37.5 61.4 40.1 75.3 42.6
73 35.4 31.1 42.9 32.2 51.5 32.9
6 145 42.1 34.5 53.1 36.5 65.5 38.5
218 45.1 35.9 57.7 38.5 71.5 40.9
73 33 29.9 40.2 31 48.7 31.7
2000 7 145 38.9 33 49.5 35 61.9 36.9
218 41.6 34.3 53.9 36.8 67.6 39.3
73 30.6 28.8 37.5 29.9 45.9 30.8
8 145 35.7 31.6 45.9 33.5 58.2 35.5
218 38.1 32.7 50 35.2 63.7 37.6
73 28.5 27.6 34.9 28.8 43 29.7
9 145 32.7 30.1 42.5 32.1 54.4 34
218 34.5 31.1 46.1 33.6 59.8 36.1
73 44 40.1 51.7 40.9 60.8 41.4
5 145 54.3 45.6 66.7 47.6 81.1 49.3
218 59.4 48.2 74.3 50.8 90.8 53.2
73 41.4 38.7 48.9 39.7 57.7 40.2
6 145 50.6 44 62.6 45.9 76.7 47.6
218 55.2 46.2 69.7 48.8 86.1 51.3
73 38.9 37.2 46.1 38.5 54.9 39.2
2800 7 145 47 42.2 58.6 44.2 72.4 45.9
218 51 44.2 65 46.9 81.2 49.3
73 36.5 35.7 43.2 37.1 51.8 37.9
8 145 43.5 40.4 54.6 42.5 67.9 44.3
218 46.8 42.3 60.3 44.9 76.4 47.4
73 34.1 34.1 40.4 35.9 48.6 36.8
9 145 40.1 38.6 50.6 40.8 63.5 42.6
218 42.9 40.4 55.6 43 71.4 45.5
73 47.3 44.5 55 45.4 63.9 45.7
5 145 59 51.4 71.8 53.2 86.7 54.6
218 65.2 54.5 80.9 57 98.6 59.3
73 44.7 42.8 52.4 44.2 60.7 44.5
6 145 55.2 49.4 67.6 51.3 82 52.9
218 60.6 52.3 75.9 54.9 93.4 57.3
73 42.1 41.2 49.1 42.7 57.4 43.3
3400 7 145 51.5 47.6 63.2 49.6 77.3 51
218 56.1 50.2 70.7 52.9 88.1 55.2
73 39.5 39.4 46.1 41.4 54.2 43
8 145 47.7 45.6 58.9 47.7 72.6 49.3
218 51.8 48 65.7 50.7 82.8 53.2
73 37.2 37.2 43.2 39.9 51.2 40.7
9 145 44.3 43.5 54.6 45.9 67.9 47.5
218 47.6 45.8 60.8 48.7 77.4 51.1

7
PERFORMANCE DATA COIL PRESSURE DROP

40LM 120

40LM 150

40LM 200

8
FAN PERFORMANCE

40LM 120

40LM 150

500
EXTERNAL STATIC PRESSURE (Pa)

400

300

200

100

0
1700 1800 1900 2000 2100 2200 2300 2400 2500 2600
Air Volume Flowrate (l /s)

40LM 200

500
EXTERNAL STATIC PRESSURE (Pa)

400

300

200

100

0
2100 2300 2500 2700 2900 3100 3300 3500
Air Volume Flowrate (l /s)

9
SOUND PRESSURE LEVEL DATA

MODEL OCTAVE BAND CENTRE FREQUENCY Hz


63 125 250 500 1000 2000 4000 8000 dB(A)
40LM120 H 30 40 48 48 53 54 45 35 58
M 28 37 45 46 51 53 44 34 56
L 25 35 40 42 49 50 41 30 53
40LM150 41.6 51 52.6 52.1 51.3 50.6 45.8 37.1 59
40LM200 43.5 51.6 53.4 55.2 53.3 51.5 47.2 41.9 60.7
Note: Sound measurement in accordance with standard JIS B8616-2006 (1.5 Meter below the unit bottom at 8mm ESP)

10
FAN MOTOR AND DRIVES

UNIT FAN MOTOR FAN PITCH DIA BELT(SPZ) CENTER FAN SHAFT
40LM (Kw) RPM MOTOR FAN SIZE NO LINE DIA (mm)
PULLEY PULLEY (mm) DISTANCE
STD 2.2 879 80 132 1040 2 335.8 ± 40 +0
150 35.0 -0.062
ALT 3 - - - - - 335.8 ± 40

STD 3 906 100 160 1112 2 335.8 ± 40 +0


200 35.0 -0.062
ALT 3.7 - - - - - 335.8 ± 40
Note: Above data are based on IEC standard motor size.

Equation 1: Pulley Diameter PDf Fan pulley pitch diameter (mm)


PDf = PDm x RPSm PDm Motor pulley pitch diameter (mm)
RPSf RPSf Fan speed
RPSm Motor speed
PDm = PDf x RPSf Lb V belt length (mm)
RPSm Lw Center line distance (mm)
Sb V belt size

Equation 2: V Belt Length (mm)


Lb = 2 x Lw + л(PDm + PDf) + (PDm - PDf)2
2 4 x Lw

Equation 3: V Belt Size


Sb = Lb
25.4

11
GUIDE SPECIFICATIONS

Part 1 – GENERAL 2.4 Fan


1.1 System Description Direct driven (40LM120) or belt driven
Horizontal, furred-in, above ceiling for ducting (40LM150/200) double width fan wheel with forward
room fan coil unit (40LM120). Horizontal or vertical curved blades shall be statically and dynamically
ducted fan coil unit (40LM150/200). balanced. Fan wheels shall be constructed of high
density reinforced polypropylene. (40LM150/200) or
fan wheels shall be constructed of steel
(40LM150/200).
1.2 Quality Assurance
Unit shall be tested in accordance with ARI
Standard 440. Each coil shall be factory tested for
leakage at 400 psig air pressure with coil 2.5 Coils
submerged in water. Factory is ISO-9001 certified. Drain pan covers entire length and width of coil till
the headers. Drain pan inside coated and outside
insulated,
Standard base unit shall be equipped with a 4-row
1.3 Delivery Storage and Handling
coil for installation in a 2-pipe system. Coils shall
Each unit shall be individually packaged from point have 9.5mm copper tubes, aluminum fins bonded to
of manufacture. Units shall be handled and stored the tubes by mechanical expansion. Each coil shall
in accordance with the manufacturer’s instructions. have a manual air vent and threaded connections
field piping. Working pressure 1.72 Mpa, 0.105mm
fin thickness and 0.24mm tube wall thickness.
Part 2 – PRODUCTS
Equipment
2.1 General 2.6 Operating Characteristics
Units shall be completed with water coil(s), fan(s), A one coil unit installed in a 2-pipe system shall be
motor(s), drain pan, filters and all required wiring, capable of providing cooling as determined by the
collars for ducted units. Unit insulation and unit’s operating mode of the central water supply system.
drain pan insulation are UL94 compliance.

2.7 Electrical Requirements


2.2 40LM Furred-in Units Standard unit shall operate on 230V±10%, single
Base (40LM120) unit with factory installed plenum phase, 50Hz electric power.
section and cleanable filter as shown on
equipment drawings. The plenum (40LM120)
shall be rear air return. Shall enclose the
2.8 Motor(s)
fan/motor assemblies and shall be lined with
12.7mm thick PU insulation 20kg/m³ density and 40LM120’s fan motors shall be 3-speed, 230V,
6.0mm PE insulation 28.6kg/m³ density on the single phase, 50Hz permanent split capacitor type,
drain pan. Unit shall have a removable panel to with ball type bearings and over-sized oil reservoirs
provide access to fan/motor assemblies and unit to ensure lubrication. The fan motor(s) shall be
identification label. equipped with integral automatic temperature reset
for motor protection. Motor insulation is Class E and
motor is open drip proof type. Totally enclosed fan
cooled motors with belt driven are used on
2.3 40LM150/200 Horizontal & Vertical 40LM150/200.
Installations
Unit can be installed in vertical installation or
hanging in horizontal installation. The inner
2.9 Filter
insulation of 12.7mm PU insulation 20kg/m³ and
Permanent washable synthetic media filters with
6.0mm PE insulation 28.6kg/m³ on the drain pan
12mm thick and G2 filter class as per European
and include a removable panel to provide access
Union EN779.
to the fan/ motor assembly.

12
Carrier International Sdn. Bhd. (3385-T)
Lot 4, Jalan P/6, 43650 Bandar Baru Bangi,
Selangor Darul Ehsan, Malaysia.
Tel: 03-8913 7600

40LM2 REV-5

01 2015

Manufacturer reserves the right to discontinue, or


change at any time, specifications or designs
40LM2-A15-7PD SUPERCEDES 40LM-E13-6PD without notice and without incurring obligations.
.
40LM2-A15-7PD

You might also like