Bellows Sealed Matering Valves BM Series (Ms-01-23) R3
Bellows Sealed Matering Valves BM Series (Ms-01-23) R3
Bellows Sealed Matering Valves BM Series (Ms-01-23) R3
com
Bellows-Sealed
M e t e r i n g Va l v e s
BM Series
■ Micrometer handle for precise, repeatable flow settings
Technical Data
Body-to- Internal
Bellows Stem Volume Metering stem tip shown;
Series Seal Stem Tip Taper Cv in.3 (cm3) regulating stem tip available
BMG Metering 3° 0.019 0.07 (1.1)
Gasket
BMRG Regulating 20° 0.30 0.11 (1.6)
BMW Metering 3° 0.019 0.07 (1.1)
Welded
BMRW Regulating 20° 0.30 0.11 (1.6)
Materials of Construction
Material Grade/
1 Component Series ASTM Specification
1 Handle Silver-mist chrome-plated 313 SS/A582
All
Set screw Alloy steel/ANSI 18.3
2 2 Bushing
All
303 SS/A582
Set screw Alloy steel/ANSI 18.3
3 3 Barrel Silver-mist chrome-plated 313 SS/A582
All
4 Set screw Alloy steel/ANSI 18.3
5 4 Panel mount nut All 316 SS/B783
5 Bonnet nut All Silver-plated 316 SS/A479
6 Bonnet 316 SS/A479
All
Lock screw Alloy steel/ANSI 18.3
6 7 Actuator 416 SS/A582
All
Actuator pins 420 SS/A276
8 Bearing All 420C SS
9 Stem All 316 SS/A479
Bellows All 321 SS/A269
7 Weld ring All 316 SS/A479
10 Stem adapter BMRG, BMRW 316 SS/A479
11 Stem tip All Hard chrome-plated 316 SS/A479
8 12 Gasket BMG, BMRG Silver-plated 316 SS/A580
9 9
13 Body All 316 SS/A479
10 Lubricants All Molybdenum disulfide-based dry film and paste
Metering 11
12 11 Regulating Wetted components listed in italics.
13
BM Series Metering Valves 3
100 100 6
6
60 4 60 4
40 40
2 2
20 20
1.0 1.0
10 0.6 10 0.6
6 0.4 6 0.4
4 4
0.2 0.2
2 2
0.1 0.1
0.08 1 0.08
1
0.01 0.02 0.04 0.1 0.2 0.4 1.0 2 4 6 10 20 40 60 100 0.004 0.01 0.02 0.04 0.06 0.1 0.2 0.4 0.6 1.0 2 4 6 8 10
Air Flow, std ft3/min Water Flow, U.S. gal/min
BMRG, BMRW
0.020
BMG, BMW
0.20
series valves are not intended for shutoff service
0.15 0.015
BMG, BMW
BMRG and BMRW Series
0.10 0.010
Following a helium leak test at the valve seat to a maximum
0.05 0.005 leak rate of 7 10–7 std cm3/s, the handle is set at 0. BMRW
series valves are not recommended for shutoff above 600°F
0 0
0 1 2 3 4 5 6 (315°C).
Number of Turns Open
Ordering Information and Dimensions
Select an ordering number. End Connections Dimensions, in. (mm)
Ordering
Dimensions, in inches and (millimeters), Type Size Series Number Orifice A B C D
are for reference only and are subject to
0.057 5.24
change. BMG SS-4BMG
(1.4) (133) 1.45
1.02 (36.8)
(25.9) 0.166 5.22
Fractional BMRG SS-4BMRG
(4.2) (133)
Swagelok 1/4 in.
tube fitting 0.057 5.17
BMW SS-4BMW
(1.4) (131) 1.42
0.166 5.15 (36.1)
BMRW SS-4BMRW
(4.2) (131) 0.56 1.06
0.057 5.24 (14.2) (26.9)
BMG SS-6BMG-MM
(1.4) (133) 1.45
A
0.38 open 0.166 5.22 (36.8)
(9.7) Metric BMRG SS-6BMRG-MM
max (4.2) (133)
0.77 (19.6) Swagelok 6 mm
panel hole 0.057 5.17
tube fitting BMW SS-6BMW-MM
(1.4) (131) 1.42
0.166 5.15 (36.1)
BMRW SS-6BMRW-MM
Swagelok (4.2) (131)
B
tube
fittings 0.057 5.24
C BMG SS-4BMG-TW
(1.4) (133) 1.45
2.46 0.166 5.22 (36.8)
(62.5) Tube BMRG SS-4BMRG-TW
1/4 in. (4.2) (133)
socket and 0.56 1.00
1/4 in. socket 3/8 in. butt and
weld dia weld dia
tube butt 0.057 5.17 (14.2) (25.4)
3/8 in. BMW SS-4BMW-TW
weld (1.4) (131)
Tube socket 1.42
weld and tube 0.166 5.15 (36.1)
butt weld ends BMRW SS-4BMRW-TW
(4.2) (131)
1.68 0.057 5.24
(42.7) BMG SS-4BMG-VCR
(1.4) (133) 1.45
0.166 5.22 (36.8)
Integral BMRG SS-4BMRG-VCR
Integral male (4.2) (133) 0.44 1.00
male VCR 1/4 in.
VCR fittings 0.057 5.17 (11.2) (25.4)
fitting BMW SS-4BMW-VCR
(1.4) (131) 1.42
2.24
(56.9) (36.1)
0.166 5.15
10-32 UNF BMRW SS-4BMRW-VCR
(4.2) (131)
tapped holes
0.25 (6.4) deep Dimensions shown with Swagelok tube fitting nuts finger-tight.
Example: SS-4BMG-V51
Safe Product Selection Caution: Do not mix or interchange parts with those of
When selecting a product, the total system design must other manufacturers.
be considered to ensure safe, trouble-free performance.
Function, material compatibility, adequate ratings, Swagelok, VCR—TM Swagelok Company
© 2002 Swagelok Company
proper installation, operation, and maintenance are the Printed in U.S.A., MI
responsibilities of the system designer and user. January 2002, R3
MS-01-23