ARUM072DTE5 ARUM***DTE5
Tons 6 8 10 12
SimultaneousOperation2 ˚F 14 - 81 14 - 81 14 - 81 14 - 81
Dimensions (W×H×D) Body in 36-5/8 x 66-17/32 x 29-29/32 48-13/16x66-17/32x29-29/32 48-13/16x66-17/32x29-29/32 48-13/16 x 66-17/32 x 29-29/32
Quantity 1 1 1 2
Coating Black Coated Fin™ Black Coated Fin™ Black Coated Fin™ Black Coated Fin™
Heat Exhanger
Rows/Fins per Inch 2/17 2/17 2/17 3/17
18
MULTI V™ 5
ARUM***DTE5
Specifications Unit ARUM168DTE5 ARUM192DTE5 ARUM216DTE5 ARUM241DTE5
Frames ARUM168DTE5 ARUM192DTE5 ARUM216DTE5 ARUM241DTE5
Tons 14 16 18 20
Cooling Btu/h 168,000 192,000 216,000 233,100
Nominal Capacity
Heating Btu/h 189,000 216,000 243,000 243,000
Cooling Btu/h 160,000 184,000 206,000 222,000
Rated Capacity1
Heating Btu/h 180,000 206,000 230,000 230,000
Power Voltage V / Hz / ø 460/60/3 460/60/3 460/60/3 460/60/3
Power/Communication Wiring No x AWG 2 x 18 2 x 18 2 x 18 2 x 18
Cooling ˚F 5-122 5-122 5-122 5-122
Operating Range Heating ˚F -22 - 61 -22 - 61 -22 - 61 -22 - 61
SimultaneousOperation2 ˚F 14 - 81 14 - 81 14 - 81 14 - 81
Dimensions (W×H×D) Body in 48-13/16 x 66-17/32 x 29-29/32 48-13/16 x 66-17/32 x 29-29/32 48-13/16x66-17/32x29-29/32 48-13/16 x 66-17/32 x 29-29/32
Net lbs 639 659 666 666
Weight
Shipping lbs 666 688 694 694
Sound Pressure3 dB(A) 61.0 62.0 64.0 65.0
Fan (Propeller) CFM 11,300 11,300 11,300 11,300
Type DC Scroll DC Scroll DC Scroll DC Scroll
Compressor (DC Scroll) Oil Type PVE/FVC68D PVE/FVC68D PVE/FVC68D PVE/FVC68D
Quantity 2 2 2 2
Coating Black Coated Fin™ Black Coated Fin™ Black Coated Fin™ Black Coated Fin™
Heat Exhanger
Rows/Fins per Inch 3/17 3/17 3/17 3/17
Liquid Line in 5/8 5/8 5/8 5/8
Piping L/P Vapor Line in 1-1/8 1-1/8 1-1/8 1-3/8
H/P Vapor Line4 in 7/8 1-1/8 1-1/8 1-1/8
Type R410A R410A R410A R410A
Refrigerant Charge lbs 26.5 30.9 37.5 37.5
Control EEV EEV EEV EEV
Maximum Number of Indoor Units5 29 32 35 39
1. Rated capacity is certified under AHRI Standard 1230. Ratings are subject to change without notice. Current certified ratings are available at www.ahridirectory.org.
2. Temperatures shown are for Simultaneous operation - primarily cooling. The simultaneous operation range (primarily heating) is 14°F to 61°F.
3. Sound pressure levels are tested in an anechoic chamber under ISO Standard 3745.
4. Used in Heat Recovery Systems only.
5. The System Combination Ratio must be between 50 and 130%.
6. Due to our commitment to continued innovation, some specifications may be changed without notification.
MULTI V 5
ARUM***DTE5
Specifications Unit ARUM264DTE5 ARUM288DTE5 ARUM312DTE5 ARUM336DTE5
ARUM096DTE5 ARUM096DTE5 ARUM096DTE5 ARUM121DTE5
Frames
ARUM168DTE5 ARUM192DTE5 ARUM216DTE5 ARUM216DTE5
Tons 22 24 26 28
Cooling Btu/h 264,000 288,000 312,000 336,000
Nominal Capacity
Heating Btu/h 297,000 324,000 351,000 378,000
Cooling Btu/h 252,000 276,000 298,000 320,000
Rated Capacity1
Heating Btu/h 282,000 308,000 332,000 358,000
Power Voltage V / Hz / ø 460/60/3 460/60/3 460/60/3 460/60/3
Power/Communication Wiring No x AWG 2 x 18 2 x 18 2 x 18 2 x 18
Cooling ˚F 5-122 5-122 5-122 5-122
Operating Range Heating ˚F -22 - 61 -22 - 61 -22 - 61 -22 - 61
SimultaneousOperation2 ˚F 14 - 81 14 - 81 14 - 81 14 - 81
Dimensions (W×H×D) Body in 97-5/8 x 66-17/32 x 29-29/32 97-5/8 x 66-17/32 x 29-29/32 97-5/8 x 66-17/32 x 29-29/32 97-5/8 x 66-17/32 x 29-29/32
Net lbs 507+639 507+659 507+666 507+666
Weight
Shipping lbs 534+666 534+688 534+694 534+694
Sound Pressure3 dB(A) 63.0 63.0 65.0 65.0
Fan (Propeller) CFM 22,600 22,600 22,600 22,600
Type DC Scroll DC Scroll DC Scroll DC Scroll
Compressor (DC Scroll) Oil Type PVE/FVC68D PVE/FVC68D PVE/FVC68D PVE/FVC68D
Quantity 3 3 3 3
Coating Black Coated Fin™ Black Coated Fin™ Black Coated Fin™ Black Coated Fin™
Heat Exhanger
Rows/Fins per Inch 2/17+3/17 2/17+3/17 2/17+3/17 2/17+3/17
Liquid Line in 3/8 + 5/8 3/8 + 5/8 3/8 + 5/8 1/2 + 5/8
Piping L/P Vapor Line in 7/8 + 1-1/8 7/8 + 1-1/8 7/8 + 1-1/8 1-1/8 + 1-1/8
H/P Vapor Line4 in 3/4 + 7/8 3/4 + 1-1/8 3/4 + 1-1/8 3/4 + 1-1/8
Type R410A R410A R410A R410A
Refrigerant Charge lbs 23.2+26.5 23.2+30.9 23.2+37.5 23.2+37.5
Control EEV EEV EEV EEV
Maximum Number ofIndoor Units5 42 45 52 55
20
MULTI V™ 5
ARUM***DTE5
Tons 30 32 34
Cooling Btu/h 360,000 384,000 408,000
Nominal Capacity
Heating Btu/h 405,000 432,000 459,000
Cooling Btu/h 344,000 366,000 390,000
Rated Capacity1
Heating Btu/h 384,000 410,000 434,000
Power Voltage V / Hz / ø 460/60/3 460/60/3 460/60/3
Power/Communication Wiring No x AWG 2 x 18 2 x 18 2 x 18
Cooling ˚F 5-122 5-122 5-122
SimultaneousOperation 2
˚F 14 - 81 14 - 81 14 - 81
Dimensions (W×H×D) Body in 97-5/8 x 66-17/32 x 29-29/32 97-5/8 x 66-17/32 x 29-29/32 97-5/8 x 66-17/32 x 29-29/32
1. Rated capacity is certified under AHRI Standard 1230. Ratings are subject to change without notice. Current certified ratings are available at www.ahridirectory.org.
2. Temperatures shown are for Simultaneous operation - primarily cooling. The simultaneous operation range (primarily heating) is 14°F to 61°F.
3. Sound pressure levels are tested in an anechoic chamber under ISO Standard 3745.
4. Used in Heat Recovery Systems only.
5. The System Combination Ratio must be between 50 and 130%.
6. Due to our commitment to continued innovation, some specifications may be changed without notification.
MULTI V 5
ARUM***DTE5
22
MULTI V™ S HEAT PUMP
ARUN***GSS4
Dimensions (W×H×D) Body in 37-13/32 x 32-27/32 x 13 37-13/32 x 54-11/32 x 13 37-13/32 x 54-11/32 x 13 37-13/32 x 54-11/32 x 13
Quantity 1 1 1 1
Coating Gold Fin / Hydrophillic Gold Fin / Hydrophillic Gold Fin / Hydrophillic Gold Fin / Hydrophillic
Heat Exhanger
Rows/Fins perInch 2/14 2/14 2/14 3/14
1. Rated capacity is certified under AHRI Standard 1230. Ratings are subject to change without notice. Current certified ratings are available at www.ahridirectory.org.
2. Cooling range with the Low Ambient Baffle Kit (sold separately) is -9.9°F to +122°F.
3. Sound pressure levels are tested in an anechoic chamber under ISO Standard 3745.
4. The System Combination Ratio must be between 50 and 130%.
5. Due to our commitment to continued innovation, some specifications may be changed without notification.
MULTI V S
ARUB060GSS4
Cooling2 ˚F 23 - 122
Operating Range
Heating ˚F -13 - 61
Type DC Inverter
Quantity 1
Type R410A
Control EEV
1. Rated capacity is certified under AHRI Standard 1230. Ratings are subject to change without notice. Current certified ratings are available at www.ahridirectory.org.
2. Cooling range with the Low Ambient Baffle Kit (sold separately) is -9.9°F to +122°F.
3. Sound pressure levels are tested in an anechoic chamber under ISO Standard 3745.
4. The System Combination Ratio must be between 50 and 130%.
5. Due to our commitment to continued innovation, some specifications may be changed without notification.
24
WATER SOURCE
SYSTEMS
ARWN***BAS4
Tons 6 8 10 12
Cooling Btu/h 72,000 96,000 119,700 144,000
Nominal Capacity
Heating Btu/h 81,000 108,000 135,000 162,000
Cooling Btu/h 69,000 92,000 114,000 138,000
Rated Capacity1
Heating Btu/h 77,000 103,000 129,000 154,000
Power Voltage V / Hz / ø 208-230/60/3 208-230/60/3 208-230/60/3 208-230/60/3
Power/Communication Wiring No x AWG 2 x 18 2 x 18 2 x 18 2 x 18
1. Rated capacity is certified under AHRI Standard 1230. Ratings are subject to change without notice. Current certified ratings are available at www.ahridirectory.org.
2. Sound pressure levels are tested in an anechoic chamber under ISO Standard 3745.
3. The System Combination Ratio must be between 50 and 130%.
4. Due to our commitment to continued innovation, some specifications may be changed without notification.
26
MULTI V™ WATER IV HEAT PUMP (208-230V)
ARWN***BAS4
Tons 16 20 24
Cooling Btu/h 192,000 239,400 287,700
Nominal Capacity
Heating Btu/h 216,000 270,000 324,000
Cooling Btu/h 184,000 228,000 274,000
Rated Capacity1
Heating Btu/h 206,000 256,000 308,000
Power Voltage V / Hz / ø 208-230/60/3 208-230/60/3 208-230/60/3
Power/Communication Wiring No x AWG 2 x 18 2 x 18 2 x 18
Dimensions (W×H×D) Body in 63-1/2x39-1/4x19-3/4 63-1/2x39-1/4x19-3/4 63-1/2x39-1/4x19-3/4
Net lbs 280 x 2 280 x 2 280 x 2
Weight
Shipping lbs 302 x 2 302 x 2 302 x 2
Sound Pressure2 dB(A) 54/60 59/59 59/58
Cooling ˚F 23 - 113 23 - 113 23 - 113
Water Temperature Range
Heating ˚F 14 - 113 14 - 113 14 - 113
Type DC Scroll DC Scroll DC Scroll
Compressor Oil Type PVE/FVC68D PVE/FVC68D PVE/FVC68D
Quantity 2 2 2
Type Stainless Steel Plate Stainless Steel Plate Stainless Steel Plate
Heat Exhanger Flow Rate Nominal GPM 20.3 + 30.4 30.4 + 30.4 35.5 + 35.5
Pressure Drop ft wg 3.7 + 6.9 6.9 + 6.9 9.2 + 9.2
Liquid Line in 3/8 + 1/2 1/2 + 1/2 1/2 + 1/2
Piping
Vapor Line in 7/8 + 1-1/8 1-1/8 + 1-1/8 1-1/8 + 1-1/8
Type R410A R410A R410A
Refrigerant Charge lbs 12.8 + 12.8 12.8 + 12.8 12.8 + 12.8
Control EEV EEV EEV
Maximum Number of Indoor Units3 32 39 45
1. Rated capacity is certified under AHRI Standard 1230. Ratings are subject to change without notice. Current certified ratings are available at www.ahridirectory.org.
2. Sound pressure levels are tested in an anechoic chamber under ISO Standard 3745.
3. The System Combination Ratio must be between 50 and 130%.
4. Due to our commitment to continued innovation, some specifications may be changed without notification.
MULTI V WATERIV
ARWN***BAS4
28
MULTI V™ WATER IV HEAT PUMP (460V)
ARWN***DAS4
Tons 6 8 10 12 16
Cooling Btu/h 72,000 96,000 119,700 144,000 192,000
Nominal Capacity
Heating Btu/h 81,000 108,000 135,000 162,000 216,000
Cooling Btu/h 69,000 92,000 114,000 138,000 184,000
Rated Capacity1
Heating Btu/h 77,000 103,000 129,000 154,000 206,000
Heat Exhanger Flow Rate Nominal GPM 20.3 25.4 30.4 35.5 50.7
1. Rated capacity is certified under AHRI Standard 1230. Ratings are subject to change without notice. Current certified ratings are available at www.ahridirectory.org.
2. Sound pressure levels are tested in an anechoic chamber under ISO Standard 3745.
3. The System Combination Ratio must be between 50 and 130%.
4. Due to our commitment to continued innovation, some specifications may be changed without notification.
MULTI V WATERIV
ARWN***DAS4
Tons 20 24 28
Quantity 2 2 2
Type Stainless Steel Plate Stainless Steel Plate Stainless Steel Plate
Heat Exhanger FlowRateNominal GPM 25.4 + 35.5 35.5 + 35.5 50.7 + 35.5
30
MULTI V™ WATER IV HEAT PUMP (460V)
ARWN***DAS4
1. Rated capacity is certified under AHRI Standard 1230. Ratings are subject to change without notice. Current certified ratings are available at www.ahridirectory.org.
2. Sound pressure levels are tested in an anechoic chamber under ISO Standard 3745.
3. The System Combination Ratio must be between 50 and 130%.
4. Due to our commitment to continued innovation, some specifications may be changed without notification.
MULTI V WATERIV
ARWB***BAS4
Tons 6 8 10 12
Cooling Btu/h 72,000 96,000 119,700 144,000
Nominal Capacity
Heating Btu/h 81,000 108,000 135,000 162,000
Cooling Btu/h 69,000 92,000 114,000 138,000
Rated Capacity 1
Heat Exhanger Flow Rate Nominal GPM 20.3 25.4 30.4 35.5
1.Rated capacity is certified under AHRI Standard 1230. Ratings are subject to change without notice. Current certified ratings are available at www.ahridirectory.org.
2. Sound pressure levels are tested in an anechoic chamber under ISO Standard 3745.
3. The System Combination Ratio must be between 50 and 130%.
4. Due to our commitment to continued innovation, some specifications may be changed without notification.
32
MULTI V™ WATER IV HEAT RECOVERY (208-230V)
ARWB***BAS4
Tons 16 18 20 24
Quantity 2 2 2 2
Type Stainless Steel Plate Stainless Steel Plate Stainless Steel Plate Stainless Steel Plate
Heat Exhanger Flow Rate Nominal GPM 20.3 + 30.4 20.3 + 35.5 30.4 + 30.4 35.5 + 35.5
Pressure Drop ft wg 3.7 + 6.9 3.7 + 9.2 6.9 + 6.9 9.2 + 9.2
Liquid Line in 3/8 + 1/2 3/8 + 1/2 1/2 + 1/2 1/2 + 1/2
Piping L/P Vapor Line in 7/8 + 1-1/8 7/8 + 1-1/8 1-1/8 + 1-1/8 1-1/8 + 1-1/8
H/P Vapor Line in 3/4 + 3/4 3/4 + 3/4 3/4 + 3/4 3/4 + 3/4
Refrigerant Charge lbs 12.8 + 12.8 12.8 + 12.8 12.8 + 12.8 12.8 + 12.8
MaximumNumberofIndoorUnits3 32 35 39 45
1.Rated capacity is certified under AHRI Standard 1230. Ratings are subject to change without notice. Current certified ratings are available at www.ahridirectory.org.
2. Sound pressure levels are tested in an anechoic chamber under ISO Standard 3745.
3. The System Combination Ratio must be between 50 and 130%.
4. Due to our commitment to continued innovation, some specifications may be changed without notification.
MULTI V WATERIV
ARWB***BAS4
34