EFFICIENCY AND NOISE REPORT IN ACCORDANCE WITH

CYBENETICS ETA AND CYBENETICS LAMBDA PROCEDURE Corsair CX450 (CWT)

Lab ID#: 189


Report:
Receipt Date: Apr 29, 2018
Test Date: May 8, 2018 Report Date: May 10, 2018

DUT INFORMATION DUT SPECIFICATIONS

Brand Corsair Rated Voltage (Vrms) 100-240

Manufacturer (OEM) CWT Rated Current (Arms) 6-3

Series CX Rated Frequency (Hz) 47-63

Model Number Rated Power (W) 450

Serial Number 17037185000017680408 Type ATX12V

DUT Notes RPS0053 / CP-9020120 120mm Rifle Bearing Fan


Cooling
(D12SM-12)

Semi-Passive Operation ✗

Cable Design Fixed cables

POWER SPECIFICATIONS

Rail 3.3V 5V 12V 5VSB -12V

Amps 20 20 37.4 3 0.8


Max. Power
Watts 110 448.8 15 9.6

Total Max. Power (W) 450

CABLES AND CONNECTORS

Modular Cables

Description Cable Count Connector Count (Total) Gauge In Cable Capacitors

ATX connector 20+4 pin (600mm) 1 1 18-22AWG No

4+4 pin EPS12V (670mm) 1 1 18AWG No

6+2 pin PCIe (600mm) 1 1 18AWG No

SATA (410mm+120mm) 2 4 18AWG No

4 pin Molex (410mm+120mm+120mm+120mm) 1 4 18AWG No

AC Power Cord (1370mm) - C13 coupler 1 1 18AWG -

All data and graphs included in this test report can be used by any individual on the following conditions:
› It should be mentioned that the test results are provided by Cybenetics PAGE 1/9
› The link to the original test results document should be provided in any case

Cybenetics offers the ETA and Lambda voluntary certification programs, through which the efficient www.cybenetics.com -info@cybenetics.com
and silent power supplies are promoted 4004 MESA GEITONIA, LIMASSOL, CYPRUS
EFFICIENCY AND NOISE REPORT IN ACCORDANCE WITH
CYBENETICS ETA AND CYBENETICS LAMBDA PROCEDURE Corsair CX450 (CWT)

General Data
Manufacturer (OEM) Channel Well Technology

Platform Model Custom

Primary Side
Transient Filter 4x Y caps, 3x X caps, 2x CM chokes, 1x MOV

Inrush Protection NTC Thermistor

Bridge Rectifier 1x

APFC MOSFETS 2x Silan Microelectronics SVF13N50F (500V, 10A @ 100°C, 0.52Ohm)

APFC Boost Diode STi STTH8S06FP (600V, 8A @ 150°C)

Hold-up Cap 1x Nippon Chemi-Con (450V, 180uF, 2000h @ 105°C, KMR)

Main Switchers 2x Silan Microelectronics SVF13N50F (500V, 10A @ 100°C, 0.52Ohm)

APFC Controller Infineon ICE3PCS01G - CM03X

Resonant Controller Infineon ICE2HS01G

Primary side: Half-Bridge & LLC Resonant Controller


Topology
Secondary side: Synchronous Rectification & DC-DC converters

Secondary Side
+12V MOSFETS 4x

DC-DC Converters: 2x Ubiq QM3016D (30V, 68A @ 100°C, 4mOhm), 2x Ubiq QM3006D (30V, 57A @ 100°C, 5.5mOhm)
5V & 3.3V
PWM Controller: APW7159C

Electrolytics: Elite ED (2-5,000h @ 105°C), 1x Chemi-Con (4-10,000h @ 105°C, KY)


Filtering Capacitors
Polymers: Elite (RP, RH, GT), Apaq

Supervisor IC Weltrend WT7502 (OVP, UVP, SCP, PG)

Fan Model Hong Hua HA1225M12F-Z (120mm, 12V, 0.45A, 2050RPM, Fluid Dynamic Bearing)

5VSB Circuit
Rectifiers CET CEF04N7G (700V, 4A, 3.3Ohm), Vishay SBL1040CT (40V, 10A)

Standby PWM Controller On-Bright OB5269

All data and graphs included in this test report can be used by any individual on the following conditions:
› It should be mentioned that the test results are provided by Cybenetics PAGE 2/9
› The link to the original test results document should be provided in any case

Cybenetics offers the ETA and Lambda voluntary certification programs, through which the efficient www.cybenetics.com -info@cybenetics.com
and silent power supplies are promoted 4004 MESA GEITONIA, LIMASSOL, CYPRUS
EFFICIENCY AND NOISE REPORT IN ACCORDANCE WITH
CYBENETICS ETA AND CYBENETICS LAMBDA PROCEDURE Corsair CX450 (CWT)

RESULTS

Temperature Range (°C /°F) 30-32 / 86-89.6 (+-2℃ / +- 3.6℉)

ErP Lot 3/6 Ready ✓

(EU) No 617/2013 Compliance ✓

115V

Average Efficiency 84.935%

Efficiency With 10W (≤500W) or 2% (>500W) 0.000

Average Efficiency 5VSB 78.172%

Standby Power Consumption (W) 0.0532540

Average PF 0.995

Avg Noise Output 27.37 dB(A)

Efficiency Rating (ETA) ETA-S

Noise Rating (LAMBDA) LAMBDA-A-

TEST EQUIPMENT

Chroma 6314A x2 Chroma 63601-5 x2


63123A x6 Chroma 63600-2
Electronic Loads
63102A 63640-80-80 x10
63101A 63610-80-20

AC Sources Chroma 6530, Chroma 61604

Power Analyzers N4L PPA1530, N4L PPA5530

Oscilloscopes Picoscope 4444 & 3424, Keysight DSOX3024A, Rigol DS2072A

Voltmeter Keithley 2015 THD 6.5 Digit

Sound Analyzer Bruel & Kjaer 2250-L G4

Microphone Bruel & Kjaer Type 4955-A, Bruel & Kjaer Type 4189

Data Loggers Picoscope TC-08 x2, Labjack U3-HV x2

All data and graphs included in this test report can be used by any individual on the following conditions:
› It should be mentioned that the test results are provided by Cybenetics PAGE 3/9
› The link to the original test results document should be provided in any case

Cybenetics offers the ETA and Lambda voluntary certification programs, through which the efficient www.cybenetics.com -info@cybenetics.com
and silent power supplies are promoted 4004 MESA GEITONIA, LIMASSOL, CYPRUS
EFFICIENCY AND NOISE REPORT IN ACCORDANCE WITH
CYBENETICS ETA AND CYBENETICS LAMBDA PROCEDURE Corsair CX450 (CWT)

EFFICIENCY UNDER HIGH AMBIENT TEMPERATURE


INFO

The PSU`s efficiency under high ambient


temperatures with 115V and 230V input. For this
graph the results of the 10-110% load regulation
table are used

5VSB EFFICIENCY
INFO

This graph depicts the efficiency levels of the 5VSB


rail with 115V and 230V input

All data and graphs included in this test report can be used by any individual on the following conditions:
› It should be mentioned that the test results are provided by Cybenetics PAGE 4/9
› The link to the original test results document should be provided in any case

Cybenetics offers the ETA and Lambda voluntary certification programs, through which the efficient www.cybenetics.com -info@cybenetics.com
and silent power supplies are promoted 4004 MESA GEITONIA, LIMASSOL, CYPRUS
EFFICIENCY AND NOISE REPORT IN ACCORDANCE WITH
CYBENETICS ETA AND CYBENETICS LAMBDA PROCEDURE Corsair CX450 (CWT)

5VSB EFFICIENCY -115V (ERP LOT 3/6 & CEC)

Test # 5VSB DC/AC (Watts) Efficiency PF/AC Volts

0.042A 0.214 0.049


1 67.085%
5.082V 0.319 115.09V

0.088A 0.446 0.089


2 73.719%
5.082V 0.605 115.09V

0.542A 2.753 0.313


3 78.590%
5.075V 3.503 115.07V

1.002A 5.080 0.383


4 78.857%
5.068V 6.442 115.08V

1.502A 7.600 0.418


5 78.651%
5.060V 9.663 115.09V

3.001A 15.115 0.467


6 77.553%
5.036V 19.490 115.08V

5VSB EFFICIENCY -230V (ERP LOT 3/6 & CEC)

Test # 5VSB DC/AC (Watts) Efficiency PF/AC Volts

0.042A 0.214 0.016


1 62.757%
5.082V 0.341 230.22V

0.088A 0.446 0.029


2 70.016%
5.082V 0.637 230.22V

0.543A 2.753 0.145


3 77.266%
5.074V 3.563 230.22V

1.003A 5.080 0.223


4 78.034%
5.067V 6.510 230.22V

1.502A 7.599 0.276


5 78.227%
5.059V 9.714 230.22V

3.002A 15.114 0.353


6 78.165%
5.035V 19.336 230.22V

All data and graphs included in this test report can be used by any individual on the following conditions:
› It should be mentioned that the test results are provided by Cybenetics PAGE 5/9
› The link to the original test results document should be provided in any case

Cybenetics offers the ETA and Lambda voluntary certification programs, through which the efficient www.cybenetics.com -info@cybenetics.com
and silent power supplies are promoted 4004 MESA GEITONIA, LIMASSOL, CYPRUS
EFFICIENCY AND NOISE REPORT IN ACCORDANCE WITH
CYBENETICS ETA AND CYBENETICS LAMBDA PROCEDURE Corsair CX450 (CWT)

115V

All data and graphs included in this test report can be used by any individual on the following conditions:
› It should be mentioned that the test results are provided by Cybenetics PAGE 6/9
› The link to the original test results document should be provided in any case

Cybenetics offers the ETA and Lambda voluntary certification programs, through which the efficient www.cybenetics.com -info@cybenetics.com
and silent power supplies are promoted 4004 MESA GEITONIA, LIMASSOL, CYPRUS
EFFICIENCY AND NOISE REPORT IN ACCORDANCE WITH
CYBENETICS ETA AND CYBENETICS LAMBDA PROCEDURE Corsair CX450 (CWT)

EFFICIENCY GRAPH 115V


INFO

This graph depicts the PSU’s efficiency throughout


its entire operational range. For the generation of
the efficiency and noise graphs we set our loaders
to auto mode through our custom-made software
before trying thousands of possible load
combinations

NOISE GRAPH 115V


INFO

The PSU’s noise in its entire operational range and


under 30-32 °C (+-2 °C) ambient is depicted in this
graph. The X axis represents the load on the +12V
rail(s) while the Y axis is the load on the minor rails

All data and graphs included in this test report can be used by any individual on the following conditions:
› It should be mentioned that the test results are provided by Cybenetics PAGE 7/9
› The link to the original test results document should be provided in any case

Cybenetics offers the ETA and Lambda voluntary certification programs, through which the efficient www.cybenetics.com -info@cybenetics.com
and silent power supplies are promoted 4004 MESA GEITONIA, LIMASSOL, CYPRUS
EFFICIENCY AND NOISE REPORT IN ACCORDANCE WITH
CYBENETICS ETA AND CYBENETICS LAMBDA PROCEDURE Corsair CX450 (CWT)

VAMPIRE POWER -115V


INFO

This graph is generated by the PPA Standby Power


Analysis software which takes full control of the
power analyzer during the whole procedure. This
application features all of the EN50564 &
IEC62301 test limits for standby power software
testing

All data and graphs included in this test report can be used by any individual on the following conditions:
› It should be mentioned that the test results are provided by Cybenetics PAGE 8/9
› The link to the original test results document should be provided in any case

Cybenetics offers the ETA and Lambda voluntary certification programs, through which the efficient www.cybenetics.com -info@cybenetics.com
and silent power supplies are promoted 4004 MESA GEITONIA, LIMASSOL, CYPRUS
EFFICIENCY AND NOISE REPORT IN ACCORDANCE WITH
CYBENETICS ETA AND CYBENETICS LAMBDA PROCEDURE Corsair CX450 (CWT)

COMMISSION REGULATION (EU) NO 617/2013 TESTING 115V

All data and graphs included in this test report can be used by any individual on the following conditions:
› It should be mentioned that the test results are provided by Cybenetics PAGE 9/9
› The link to the original test results document should be provided in any case

Cybenetics offers the ETA and Lambda voluntary certification programs, through which the efficient www.cybenetics.com -info@cybenetics.com
and silent power supplies are promoted 4004 MESA GEITONIA, LIMASSOL, CYPRUS
EFFICIENCY AND NOISE REPORT IN ACCORDANCE WITH
CYBENETICS ETA AND CYBENETICS LAMBDA PROCEDURE Corsair CX450 (CWT)

Top side Power specifications table

CERTIFICATIONS 115V

Aris Mpitsiopoulos
Lab Director

All data and graphs included in this test report can be used by any individual on the following conditions:
› It should be mentioned that the test results are provided by Cybenetics PAGE 10/9