Location via proxy:   [ UP ]  
[Report a bug]   [Manage cookies]                

Condensadora 13ACX 2-5 TR LENNOX

Download as pdf or txt
Download as pdf or txt
You are on page 1of 36

AIR CONDITIONERS

13ACX
MERIT® Series
R-410A
E N G I N E E R I N G D ATA Bulletin No. 210451
November 2009
Supersedes October 2009

SEER up to 14.5
1.5 to 5 Tons
Cooling Capacity - 18,000 to 61,000 Btuh

MODEL NUMBER IDENTIFICATION

13 AC x - 024 - 230 - 2
Nominal SEER Minor Revision Number

Unit Type Voltage


AC= Air Conditioner 230 = 208/230V-1phase-60hz

Refrigerant Nominal Cooling Capacity


X = R-410A 018 = 1.5 tons
024 = 2 tons
030 = 2.5 tons
036 = 3 tons
042 = 3.5 tons
048 = 4 tons
060 = 5 tons
FEATURES
Contents
AHRI System Matches..................................................9 E
Dimensions....................................................................7
B
Electrical Data...............................................................6
Features........................................................................2
Field Wiring....................................................................8
Installation Clearances..................................................8
Model Number Identification..........................................1 C
Optional Accessories.....................................................6
Sound Data . .................................................................8 D
Specifications ...............................................................6
EQUIPMENT Warranty
Compressor - limited warranty for five years in
residential installations and five years in non-residential
installations.
F
All other covered components - five years in
residential installations and one year in non-residential
installations.
Refer to Lennox Equipment Limited Warranty certificate
A
included with unit for specific details.
APPLICATIONS
SEER up to 14.5. REFRIGERATION SYSTEM
1.5 through 5 ton. R-410A Refrigerant
Single-phase power supply. Non-chlorine, ozone friendly, R-410A.
Sound levels as low as 76 dB. Unit pre-charged with refrigerant.
Vertical air discharge allows concealment behind shrubs See Specification table.
at grade level or out of sight on a roof.
Matching add-on furnace indoor coils or air handlers B Condenser Fan
provide a wide range of cooling capacities and Direct drive fan moves large air volumes uniformly
applications. See AHRI System Matches. through entire condenser coil for high refrigerant cooling
capacity.
See Indoor Coils and Air Handlers sections for data.
Units shipped completely factory assembled, piped and Vertical air discharge minimizes operating sounds and
wired. Each unit test operated at the factory ensuring eliminates damage to lawn and shrubs.
proper operation. Fan motor has sleeve bearings and is inherently
Installer must set air conditioner, connect refrigerant protected.
lines and make electrical connections to complete job. Motor totally enclosed for maximum protection from
APPROVALS weather, dust and corrosion.
Certified in Accordance with the USE certification Rain shield on motor provides additional protection from
program, which is based on AHRI Standard 210/240- moisture.
2008. Louvered steel top fan guard furnished as standard.
Sound rated in Lennox reverberant sound test room Fan service access accomplished by removal of top
in Accordance with test conditions included in AHRI panel.
Standard 270-2008.
Tested in the Lennox Research Laboratory
environmental test room.
Rated According to U.S. Department of Energy (DOE)
test procedures.
Units and components within bonded for grounding to
meet safety standards for servicing required by UL,
NEC and CEC.
Units are UL listed and CSA certified.
ISO 9001 Registered Manufacturing Quality System.
For expanded ratings, see www.lennoxdavenet.com.
13ACX - 1.5 to 5 Ton Air Conditioner / Page 2
FEATURES
C Copper Tube/Enhanced Fin Coil OPTIONS
Lennox designed and fabricated coil. Expansion Valve Kits
Ripple-edged aluminum fins. Must be ordered extra and field installed on certain
Copper tube construction. indoor units. See Expansion Valve Kit Usage Table.
Lanced fins provide maximum exposure of fin surface to Chatleff-style fittings.
air stream resulting in excellent heat transfer. Freezestat
Fin collars grip tubing for maximum contact area. Installs on or near the vapor line of the indoor coil or on
Flared shoulder tubing connections/silver soldering the suction line.
construction. Senses suction line temperature and cycles the
Coil is factory tested under high pressure to ensure compressor off when suction line temperature falls
leakproof construction. below it’s setpoint.
Entire coil is accessible for cleaning. Opens at 29°F and closes at 58°F.
PVC coated steel wire coil guard furnished. Loss of Charge Switch Kit
Refrigerant Flow Control Helps protect the compressor from damage due low
RFCIV METERING SYSTEM
refrigerant charge conditions.
ORIFICE BODY RFCIV SPST, normally-closed switch, automatic reset switch
(On Coil) mounted on suction line.
ORIFICE
Refrigerant Line Kits
O−RING
LIQUID Refrigerant lines (suction & liquid) are shipped
LINE
refrigeration clean. Lines are cleaned, dried,
LIQUID pressurized and sealed at factory.
LINE SCREEN
Suction line fully insulated.
SEAL
NUT SWEAT Lines are stubbed at both ends.
CONNECTION
Not available for -060 models. Must be field fabricated.
Units applicable to expansion valve systems or RFC
systems when matched with specific indoor coils.
RFCIV:
Accurately meters refrigerant in system.
Refrigerant control is accomplished by exact sizing of
refrigerant metering orifice.
The principle involves matching indoor coil with proper
bore size of orifice in metering device.
Equalizes pressure shortly after compressor stops, unit
starts unloaded, eliminating need for additional controls.
Furnished with air conditioner.
High Capacity Liquid Line Drier
Furnished with unit for field installation.
Approved for use with R-410A systems.
Traps any moisture or dirt that could contaminate the
refrigerant system.
High Pressure Switch
Shuts off unit if abnormal operating conditions cause the
discharge pressure to rise above setting.
Protects compressor from excessive condensing
pressure.
Manual reset.

13ACX - 1.5 to 5 Ton Air Conditioner / Page 3


FEATURES
COMPRESSOR CONTROLS
D Scroll Compressor OPTIONS
Compressor features high Compressor Hard Start Kit
efficiency with uniform suction
Single-phase units are equipped with a PSC
flow, constant discharge flow and
compressor motor. This type of motor normally doesn’t
high volumetric efficiency and
need a potential relay and start capacitor.
quiet operation.
In conditions such as low voltage, this kit may be
Compressor consists of two
required to increase the compressor starting torque.
involute spiral scrolls matched
together to generate a series of Compressor Low Ambient Cut-Off
crescent shaped gas pockets Non-adjustable switch (low ambient cut-out) prevents
between them. compressor operation when outdoor temperature is
During compression, one scroll below 35°F.
remains stationary while the other Compressor Time-Off Control
scroll orbits around it. Kit prevents compressor short-cycling and allows time
Gas is drawn into the outer pocket, the pocket is sealed for suction and discharge pressure to equalize.
as the scroll rotates. Permits compressor start-up in an unloaded condition.
As the spiral movement continues, gas pockets are Automatic reset with 5 minute delay between
pushed to the center of the scrolls. Volume between the compressor shut-off and start-up.
pockets is simultaneously reduced.
Indoor Blower Off Delay Relay
When pocket reaches the center, gas is now at high
pressure and is forced out of a port located in the center Delays the indoor blower-off time during the cooling
of the fixed scrolls. cycle.
During compression, several pockets are compressed See AHRI System Matches for usage.
simultaneously resulting in a smooth continuous Low Ambient Kit
compression cycle. Air conditioners operate satisfactorily down to 45°F
Continuous flank contact, maintained by centrifugal outdoor air temperature without any additional controls.
force, minimizes gas leakage and maximizes efficiency. Low Ambient Control Kit can be field installed, allowing
Scroll compressor is tolerant to the effects of slugging unit operation down to 30°F.
and contaminants. If this occurs, scrolls separate, Thermostat
allowing liquid or contaminants to to be worked toward
Thermostat not furnished with unit. See Thermostat
the center and discharged.
bulletins in Controls Section and Lennox Price Book.
Low gas pulses during compression reduces
Timed-Off Control
operational sound levels.
Kit prevents compressor short-cycling and allows time
Compressor motor is internally protected from
for suction and discharge pressure to equalize.
excessive current and temperature.
Permits compressor start-up in an unloaded condition.
Compressor is installed in the unit on resilient rubber
mounts for vibration free operation. Automatic reset with 5 minute delay between
compressor shut-off and start-up.
OPTIONS
Compressor Crankcase Heater
Protects against refrigerant migration that can occur
during low ambient operation.
Compressor Sound Cover
A reinforced vinyl compressor cover containing a 1-1/2
inch thick batt of fiberglass insulation.
All open edges are sealed with a one-inch wide hook
and loop fastening tape.

13ACX - 1.5 to 5 Ton Air Conditioner / Page 4


FEATURES
CABINET
E Heavy gauge steel cabinet with five station metal wash
process.
Powder paint finish provides superior rust and corrosion
protection.
Painted base section.
Control box is conveniently located with all controls
factory wired.
Corner patch plate allows access to compressor
components.
Drainage holes are provided in base section for
moisture removal.
F Refrigerant Line Connections, Electrical Inlets,
Service Valves
Sweat connection suction and liquid lines are located on
corner of unit cabinet.
Fully serviceable brass service valves prevent corrosion
and provide access to refrigerant system. Suction valve
can be fully shut off, while liquid valve may be front
seated to manage refrigerant charge while servicing
system.
Refrigerant line connections and field wiring inlets are
located in one central area of cabinet for easy access.
See dimension drawing.
OPTIONS
Hail Guards
Constructed of louvered, heavy-gauge steel painted to
match cabinet.
Surrounds unit on all four sides to prevent damage to
the coil.
Mounting Base
Provides permanent foundation for outdoor units.
High density polyethylene structural material is
lightweight, sturdy, sound absorbing and will withstand
the rigors of the sun, heat, cold, moisture, oil and
refrigerant. Will not mildew or rot.
Can be shipped singly or in packages of 6 to a carton.
Unit Stand-Off Kit
Black high density polyethylene feet are available to
raise unit off of mounting surface away from damaging
moisture.
Four feet are furnished per order number.

13ACX - 1.5 to 5 Ton Air Conditioner / Page 5


SPECIFICATIONS
General Model No. 13ACX-018 13ACX-024 13ACX-030 13ACX-036 13ACX-042 13ACX-048 13ACX-060
Data Nominal Tonnage 1.5 2 2.5 3 3.5 4 5
Connections Liquid line o.d. - in. 3/8 3/8 3/8 3/8 3/8 3/8 3/8
(sweat) Suction line o.d. - in. 3/4 3/4 3/4 7/8 7/8 7/8 1-1/8
1
Refrigerant (R-410A) furnished 3 lbs. 13 oz. 4 lbs. 6 oz. 4 lbs. 4 oz. 5 lbs. 9 oz. 6 lbs. 6 oz. 7 lbs. 8 oz. 10 lbs. 0 oz.
RFCIV Metering Orifice Size 0.051 0.057 0.065 0.070 0.076 0.080 0.090
Outdoor Net face area Outer coil 11.33 11.33 13.22 13.22 16.33 21.00 18.67
Coil sq. ft. Inner coil --- --- --- --- --- --- 17.96
Tube diameter - in. 5/16 5/16 5/16 5/16 5/16 5/16 5/16
Number of rows 1 1 1 1 1 1 2
Fins per inch 26 26 26 26 26 26 22
Outdoor Diameter - in. 18 18 18 18 22 22 22
Fan Number of blades 3 3 4 4 4 4 4
Motor hp 1/10 1/10 1/5 1/5 1/4 1/4 1/4
Cfm 2350 2350 2400 2400 3500 3670 3600
Rpm 1010 1010 1090 1090 825 835 830
Watts 165 165 185 185 300 295 285
Shipping Data - lbs. 1 package 122 123 133 135 178 194 218
Electrical Data
Line voltage data - 60 hz - 1ph 208/230V 208/230V 208/230V 208/230V 208/230V 208/230V 208/230V
2
Maximum overcurrent protection (amps) 20 30 30 35 40 50 60
3
Minimum circuit ampacity 12 17.5 18.7 21.9 25.3 28.9 34.6
Compressor Rated load amps 9.0 13.4 14.1 16.6 28.8 21.8 26.3
Locked rotor amps 39 53 59 70 90 100 120
Power factor 0.98 0.98 0.98 0.99 0.99 0.99 0.99
Condenser Full load amps 0.7 0.7 1.1 1.1 1.7 1.7 1.7
Fan Motor Locked rotor amps 1.4 1.4 2.0 2.0 3.1 3.1 3.1
OPTIONAL ACCESSORIES - must be ordered extra
Compressor Crankcase Heater 93M04 • • • •
93M05 • • •
Compressor Hard Start Kit 10J42 •
88M91 • • • • • •
Compressor Low Ambient Cut-Off 45F08 • • • • • • •
Compressor Sound Cover 69J03 • • • • • • •
Compressor Time-Off Control 47J27 • • • • • • •
Freezestat 3/8 in. tubing 93G35 • • • • • • •
5/8 in. tubing 50A93 • • • • • • •
Hail Guards 92M87 • •
92M88 • •
92M93 •
92M90 •
12W21 •
Indoor Blower Off Delay Relay 58M81 • • • • • • •
Loss of Charge Switch Kit 84M23 • • • • • • •
Low Ambient Kit 34M72 • • • • • • •
Mounting Base 69J06 • • • •
69J07 • • •
Refrigerant L15-41-20, L15-41-30, • • •
Line Sets L15-41-40, L15-41-50
L15-65-30, L15-65-40, • • •
L15-65-50
Field Fabricate •
Unit Stand-Off Kit 94J45 • • • • • • •
NOTE - Extremes of operating range are plus 10% and minus 5% of line voltage.
1
Refrigerant charge sufficient for 15 ft. length of refrigerant lines.
2
HACR type circuit breaker or fuse.
3
Refer to National or Canadian Electrical Code manual to determine wire, fuse and disconnect size requirements.

13ACX - 1.5 to 5 Ton Air Conditioner / Page 6


DIMENSIONS - INCHES (MM)

4-3/8 4-3/8
INLET AIR (111) (111)

4-3/8 4-3/8
(111) (111)

INLET INLET OPTIONAL UNIT


STAND-OFF KIT (4) COMPRESSOR
(Field Installed)

AIR AIR COIL DRAIN OUTLETS


(Around perimeter of base)

6-3/8
(162) 4-3/8
SUCTION LINE (111)
CONNECTION

INLET AIR LIQUID LINE 6-3/8 4-3/8


CONNECTION (162) (111)
TOP VIEW TOP VIEW BASE SECTION

A
A
DISCHARGE AIR
CONDENSER
COIL FAN

COMPRESSOR

C B
SUCTION &
LIQUID LINE
CONNECTIONS
ELECTRICAL
INLETS

2-3/4 (70)
2 (51)

3/4 OPTIONAL UNIT


SIDE VIEW (19) STAND-OFF KIT (4) SIDE VIEW
(Field Installed)

A B C
Model No.
inches mm inches mm inches mm
13ACX-018 24-1/4 616 25-1/4 641 24-1/4 616
13ACX-024 24-1/4 616 25-1/4 641 24-1/4 616
13ACX-030 24-1/4 616 29-1/4 743 28-1/2 724
13ACX-036 24-1/4 616 29-1/4 743 28-1/2 724
13ACX-042 28-1/4 718 29-1/4 743 28-1/2 724
13ACX-048 28-1/4 718 37-1/4 946 36-1/4 921
13ACX-060 28-1/4 718 33-1/4 845 32-1/2 826

13ACX - 1.5 to 5 Ton Air Conditioner / Page 7


SOUND DATA
Octave Band Sound Power Levels dBA, re 10-12 Watts
Unit
1
Center Frequency - HZ
1
Sound Rating
Model No. Number (dB)
125 250 500 1000 2000 4000 8000
13ACX-018 53 60 64.5 68.5 67 61.5 54.5 76
13ACX-024 51.5 62 64.5 68.5 67 60.5 53.5 76
13ACX-030 52.5 62 67.5 69 67 61.5 54.5 76
13ACX-036 52.5 61 67 69 67 61.5 52.5 76
13ACX-042 58 68 73.5 75.5 74 69.5 62.5 79
13ACX-048 57.5 67 73 74.5 71 64 58.5 79
13ACX-060 57 63 69.5 71.5 71 65.5 60.5 79
NOTE - the octave sound power data does not include tonal correction.
1
Tested according to AHRI Standard 270-2008 test conditions.

FIELD WIRING INSTALLATION CLEARANCES - IN. (MM)

DISCONNECT DISCONNECT
SWITCH THERMOSTAT SWITCH See NOTES
(By Others) (Optional) (By Others)

A
B D

See See
NOTES NOTES
C
LENNOX LENNOX
AIR HEATING UNIT
CONDITIONER OR
AIR HANDLER CONTROL
UNIT
See NOTES BOX

A  - Two Wire Power NOTES:


B  - Two Wire Power (See Electrical Data) Service clearance of 30 in. (762 mm) must be maintained on
C  - Two Wire Low Voltage (18 ga. minimum) one of the sides adjacent to the control box.
D  - Four Wire Low Voltage (Electro-Mechanical) 18 ga. mini- Clearance to one of the other three sides must be 36 in. (914
mum. mm)
Five Wire Low Voltage (Electronic) 18 ga. minimum Clearance to one of the remaining two sides may be 12 in. (305
mm) and the final side may be 6 in. (152 mm).
NOTE - Field Wiring Not Furnished A clearance of 24 in. must be maintained between two units.
All wiring must conform to NEC or CEC and local electrical codes. 48 in. (1219 mm) clearance required on top of unit.

13ACX - 1.5 to 5 Ton Air Conditioner / Page 8


REFRIGERANT METERING DEVICES *tXV SUBSTITUTIONS
Model No. Refrigerant Metering Thermal Indoor Coils/Air Handlers with factory installed expansion
Orifice (RFC) Expansion valves that require field replacement
Order No. Orifice Size Valve (TXV) Model No. Indoor Coil or Air Order No.
Handler
13ACX-018 10W93 0.051 37L51
13ACX-036 CX34-50/60 37L51
13ACX-024 97M75 0.057 37L51
13ACX-030 10W99 0.065 37L51 13ACX-036 CX34-43 37L51

13ACX-036 11W02 0.070 37L51 13ACX-036 CBX32M-048 37L51


13ACX-042 97M78 0.076 39L72 13ACX-036 CBX32MV-048 37L51
13ACX-048 97M79 0.080 91M02 13ACX-036 CBX40UHV-048 37L51
13ACX-060 11W11 0.090 91M02 13ACX-036 CBX27UH-042 37L51
NOTE - CX34 upflow coils and all Lennox air handlers (except CB26UH “R”) 13ACX-036 CBX40UHV-042 37L51
are shipped with a factory installed TXV. In most cases, no change out of the
valve is needed. If a change out is required it will be listed in the following “TXV 13ACX-042 CX34-38 39L72
SUBSTITUTION” table. The correct TXV must be ordered and field installed.
C33 coils and all horizontal and downflow coils are shipped without a TXV. The 13ACX-042 CX34-50/60 39L72
TXV must be ordered and field installed. If an RFC is the required metering
device, use the RFC shipped with the outdoor unit . 13ACX-042 CX34-49 39L72
13ACX-042 CBX32M-048 39L72
*tXV SUBSTITUTIONS 13ACX-042 CBX32M-036 39L72
Indoor Coils/Air Handlers with factory installed expansion 13ACX-042 CBX32M-048 39L72
valves that require field replacement
13ACX-042 CBX27UH-048 39L72
Model No. Indoor Coil or Air Order No.
Handler 13ACX-042 CBX32MV-048 39L72
13ACX-030 CX34-42 37L51 13ACX-042 CBX40UHV-048 39L72
13ACX-030 CX34-43 37L51 13ACX-048 CX34-38 91M02
13ACX-030 CB27UH-030 37L51 13ACX-048 CX34-43 91M02
13ACX-030 CB27UH-036 37L51 *Factory installed expansion valve on the indoor coil or air handler shown
must be replaced with the expansion valve listed (ordered separately).
*Factory installed expansion valve on the indoor coil or air handler shown
must be replaced with the expansion valve listed (ordered separately).

AHRI SYSTEM MATCHES


NOTE - For the latest up-to-date system matches please visit the AHRI web site at http://www.ahridirectory.org
Model Coil or AHRI
Capacity SEER EER Furnace
No. Air Handler Reference
13ACX-018-230 + RFC 18,400 13.00 11.00 C33-19 3231313
13ACX-018-230 + RFC 18,800 13.00 11.50 C33-25 3231315
13ACX-018-230 + RFC 18,300 13.00 11.00 C33-30 3231312
13ACX-018-230 + RFC 18,500 13.50 11.00 C33-31 3231314
13ACX-018-230 + RFC 18,300 13.00 11.00 CH33-19 3231320
13ACX-018-230 + RFC 18,300 13.00 11.00 CH33-24/30 3231319
13ACX-018-230 + RFC 18,100 13.00 11.00 CR33-18 3231316
13ACX-018-230 + RFC 18,700 13.50 11.50 CR33-24 3231318
13ACX-018-230 + RFC 18,500 13.00 11.00 CR33-30/36 3231317
13ACX-018-230 + TXV 18,400 13.00 11.00 C33-24 3229597
13ACX-018-230 + TXV 18,600 13.50 11.00 C33-25 3229599
13ACX-018-230 + TXV 18,300 13.00 11.00 C33-30 3229596
13ACX-018-230 + TXV 18,900 13.00 11.50 C33-31 3229598
13ACX-018-230 + TXV 18,700 14.00 11.50 CB26UH-018 3229610
NOTES:
+ TXV = Matched with Thermostatic Expansion Valve.
+ RFC = Matched with RFC metering device.
Ratings are certified in accordance with USE certification program which is based on AHRI Standard 210/240; 95°F outdoor air temperature, 80°F db / 67°F wb entering
evaporator air with 25 ft. of connecting refrigerant lines.
All ratings include the use of a blower time delay relay (TDR). All Lennox variable-speed furnaces and Air Handlers have time delay capabilities. Other Furnaces and Air
Handlers may require an optional time delay relay (58M81) for field installation. See furnace or air handler specifications to determine if relay is needed.
*Most popular combination.
Also see Expansion Valve Kit Usage Table.

13ACX - 1.5 to 5 Ton Air Conditioner / Page 9


AHRI SYSTEM MATCHES
NOTE - For the latest up-to-date system matches please visit the AHRI web site at http://www.ahridirectory.org
Model Coil or AHRI
Capacity SEER EER Furnace
No. Air Handler Reference
13ACX-018-230 + TXV 19,100 14.00 12.00 CB27UH-018-230 3229613
13ACX-018-230 + TXV 19,200 14.00 12.00 CB27UH-024-230 3229614
13ACX-018-230 + TXV 18,600 13.50 11.50 CB30M-21/26P 3229606
13ACX-018-230 + TXV 19,300 14.00 12.00 CB30M-31P 3229608
13ACX-018-230 + TXV 18,700 14.00 11.50 CBX26UH-018 3229609
13ACX-018-230 + TXV 19,100 14.00 12.00 CBX27UH-018-230 3229611
13ACX-018-230 + TXV 19,200 14.00 12.00 CBX27UH-024-230 3229612
13ACX-018-230 + TXV 18,600 13.50 11.50 CBX32M-018/024 3229605
13ACX-018-230 + TXV 19,300 14.00 12.00 CBX32M-030 3229607
13ACX-018-230 + TXV 18,400 13.00 11.00 CH33-19 3229604
13ACX-018-230 + TXV 18,300 13.00 11.00 CH33-24/30 3229603
13ACX-018-230 + TXV 18,100 13.00 11.00 CR33-18 3229600
13ACX-018-230 + TXV 18,500 13.50 11.00 CR33-24 3229602
13ACX-018-230 + TXV 18,700 13.50 11.50 CR33-30/36 3229601
13ACX-018-230 + TXV 18,000 13.00 11.00 CX34-18/24 3229591
13ACX-018-230 + TXV 18,400 13.00 11.00 CX34-19 3229593
13ACX-018-230 + TXV 18,600 13.50 11.00 CX34-25 3229595
13ACX-018-230 + TXV 18,300 13.00 11.00 CX34-30 3229592
13ACX-018-230 + TXV 18,900 13.00 11.50 CX34-31 3229594
13ACX-024-230 + RFC 23,400 14.00 12.00 C33-19 G60UHV-36A-070 3231333
13ACX-024-230 + RFC 23,600 14.00 12.00 C33-19 G60UHV-36B-090 3231334
13ACX-024-230 + RFC 23,400 14.00 11.50 C33-19 G61MPV-36B-045 3231335
13ACX-024-230 + RFC 23,400 14.00 12.00 C33-19 G61MPV-36B-070 3231336
13ACX-024-230 + RFC 23,400 14.00 12.00 C33-19 G71MPP-36B-070 3231337
13ACX-024-230 + RFC 23,000 13.00 11.00 C33-19 3231321
13ACX-024-230 + RFC 23,800 14.00 12.00 C33-25 G60UHV-36A-070 3231338
13ACX-024-230 + RFC 23,800 14.00 12.00 C33-25 G60UHV-36B-090 3231339
13ACX-024-230 + RFC 23,800 14.00 12.00 C33-25 G61MPV-36B-045 3231340
13ACX-024-230 + RFC 23,800 14.00 12.00 C33-25 G61MPV-36B-070 3231341
13ACX-024-230 + RFC 23,800 14.00 12.00 C33-25 G71MPP-36B-070 3231342
13ACX-024-230 + RFC 23,200 13.00 11.00 C33-25 3231322
13ACX-024-230 + RFC 23,400 14.00 12.00 C33-30 G60UHV-36A-070 3231343
13ACX-024-230 + RFC 23,400 14.00 12.00 C33-30 G60UHV-36B-090 3231344
13ACX-024-230 + RFC 23,400 14.00 11.50 C33-30 G61MPV-36B-045 3231345
13ACX-024-230 + RFC 23,400 14.00 12.00 C33-30 G61MPV-36B-070 3231346
13ACX-024-230 + RFC 23,400 14.00 12.00 C33-30 G71MPP-36B-070 3231347
13ACX-024-230 + RFC 23,000 13.00 11.00 C33-30 3231323
13ACX-024-230 + RFC 24,200 14.00 12.00 C33-31 G60UHV-36A-070 3231348
13ACX-024-230 + RFC 24,400 14.00 12.00 C33-31 G60UHV-36B-090 3231349
13ACX-024-230 + RFC 24,200 14.00 12.00 C33-31 G61MPV-36B-045 3231350
13ACX-024-230 + RFC 24,200 14.00 12.00 C33-31 G61MPV-36B-070 3231351
13ACX-024-230 + RFC 24,200 14.00 12.00 C33-31 G71MPP-36B-070 3231352
13ACX-024-230 + RFC 23,800 13.50 11.00 C33-31 3231324
13ACX-024-230 + RFC 23,800 14.00 12.00 C33-36 G60UHV-36A-070 3231353
13ACX-024-230 + RFC 23,800 14.00 12.00 C33-36 G60UHV-36B-090 3231357
13ACX-024-230 + RFC 23,800 14.00 12.00 C33-36 G61MPV-36B-045 3231354
13ACX-024-230 + RFC 23,800 14.00 12.00 C33-36 G61MPV-36B-070 3231355
NOTES:
+ TXV = Matched with Thermostatic Expansion Valve.
+ RFC = Matched with RFC metering device.
Ratings are certified in accordance with USE certification program which is based on AHRI Standard 210/240; 95°F outdoor air temperature, 80°F db / 67°F wb entering
evaporator air with 25 ft. of connecting refrigerant lines.
All ratings include the use of a blower time delay relay (TDR). All Lennox variable-speed furnaces and Air Handlers have time delay capabilities. Other Furnaces and Air
Handlers may require an optional time delay relay (58M81) for field installation. See furnace or air handler specifications to determine if relay is needed.
*Most popular combination.
Also see Expansion Valve Kit Usage Table.

13ACX - 1.5 to 5 Ton Air Conditioner / Page 10


AHRI SYSTEM MATCHES
NOTE - For the latest up-to-date system matches please visit the AHRI web site at http://www.ahridirectory.org
Model Coil or AHRI
Capacity SEER EER Furnace
No. Air Handler Reference
13ACX-024-230 + RFC 23,800 14.00 12.00 C33-36 G71MPP-36B-070 3231356
13ACX-024-230 + RFC 23,200 13.00 11.00 C33-36 3231325
13ACX-024-230 + RFC 24,400 14.00 12.00 C33-38 G60UHV-36A-070 3231358
13ACX-024-230 + RFC 24,600 14.00 12.00 C33-38 G60UHV-36B-090 3231359
13ACX-024-230 + RFC 24,400 14.00 12.00 C33-38 G61MPV-36B-045 3231360
13ACX-024-230 + RFC 24,400 14.00 12.00 C33-38 G61MPV-36B-070 3231361
13ACX-024-230 + RFC 24,400 14.00 12.00 C33-38 G71MPP-36B-070 3231362
13ACX-024-230 + RFC 23,800 13.50 11.00 C33-38 3231326
13ACX-024-230 + RFC 24,000 14.00 12.00 CH23-41 G60UHV-36A-070 3231363
13ACX-024-230 + RFC 23,800 14.00 12.00 CH23-41 G60UHV-36B-090 3231364
13ACX-024-230 + RFC 23,800 14.00 12.00 CH23-41 G61MPV-36B-045 3231365
13ACX-024-230 + RFC 23,800 14.00 12.00 CH23-41 G61MPV-36B-070 3231366
13ACX-024-230 + RFC 23,800 14.00 12.00 CH23-41 G71MPP-36B-070 3231367
13ACX-024-230 + RFC 23,800 14.00 12.50 CH33-19 G60UHV-36A-070 3231384
13ACX-024-230 + RFC 23,200 13.00 11.00 CH33-19 3231330
13ACX-024-230 + RFC 24,000 14.00 12.00 CH33-25 G60UHV-36A-070 3231383
13ACX-024-230 + RFC 24,200 14.00 12.50 CH33-25 G60UHV-36B-090 3231381
13ACX-024-230 + RFC 24,200 14.00 12.00 CH33-25 G61MPV-36B-045 3231382
13ACX-024-230 + RFC 24,000 14.00 12.00 CH33-25 G61MPV-36B-070 3231380
13ACX-024-230 + RFC 24,200 14.00 12.00 CH33-25 G61MPV-36B-071 3231390
13ACX-024-230 + RFC 24,000 14.00 12.00 CH33-25 G71MPP-36B-070 3231385
13ACX-024-230 + RFC 23,600 13.00 11.00 CH33-25 3231332
13ACX-024-230 + RFC 24,400 14.00 12.50 CH33-31 G60UHV-36A-070 3231392
13ACX-024-230 + RFC 24,600 14.00 12.50 CH33-31 G60UHV-36B-090 3231389
13ACX-024-230 + RFC 24,400 14.00 12.50 CH33-31 G61MPV-36B-045 3231391
13ACX-024-230 + RFC 24,400 14.00 12.50 CH33-31 G61MPV-36B-070 3231387
13ACX-024-230 + RFC 24,400 14.00 12.50 CH33-31 G61MPV-36B-071 3231386
13ACX-024-230 + RFC 24,400 14.00 12.50 CH33-31 G71MPP-36B-070 3231388
13ACX-024-230 + RFC 23,800 13.50 11.00 CH33-31 3231331
13ACX-024-230 + RFC 23,800 14.00 12.00 CH33-36 G60UHV-36A-070 3231368
13ACX-024-230 + RFC 23,800 14.00 12.00 CH33-36 G60UHV-36B-090 3231369
13ACX-024-230 + RFC 23,800 14.00 12.00 CH33-36 G61MPV-36B-045 3231370
13ACX-024-230 + RFC 23,800 14.00 12.00 CH33-36 G61MPV-36B-070 3231371
13ACX-024-230 + RFC 23,800 14.00 12.00 CH33-36 G71MPP-36B-070 3231372
13ACX-024-230 + RFC 23,200 13.00 11.00 CH33-36 3231327
13ACX-024-230 + RFC 23,800 14.00 12.00 CR33-24 G61MPV-36B-045 3231373
13ACX-024-230 + RFC 23,600 14.00 12.00 CR33-24 G61MPV-36B-070 3231374
13ACX-024-230 + RFC 23,600 14.00 12.00 CR33-24 G71MPP-36B-070 3231375
13ACX-024-230 + RFC 23,200 13.00 11.00 CR33-24 3231328
13ACX-024-230 + RFC 24,600 14.00 12.00 CR33-30/36 G60DFV-36B-090 3231379
13ACX-024-230 + RFC 24,000 14.00 12.00 CR33-30/36 G61MPV-36B-045 3231378
13ACX-024-230 + RFC 24,000 14.00 12.00 CR33-30/36 G61MPV-36B-070 3231376
13ACX-024-230 + RFC 24,000 14.00 12.00 CR33-30/36 G71MPP-36B-070 3231377
13ACX-024-230 + RFC 23,600 13.00 11.00 CR33-30/36 3231329
13ACX-024-230 + TXV 23,600 14.00 12.00 C33-19 G60UHV-36A-070 3205730
13ACX-024-230 + TXV 23,600 14.00 12.00 C33-19 G60UHV-36B-090 3205744
13ACX-024-230 + TXV 23,600 14.00 11.50 C33-19 G61MPV-36B-045 3205758
NOTES:
+ TXV = Matched with Thermostatic Expansion Valve.
+ RFC = Matched with RFC metering device.
Ratings are certified in accordance with USE certification program which is based on AHRI Standard 210/240; 95°F outdoor air temperature, 80°F db / 67°F wb entering
evaporator air with 25 ft. of connecting refrigerant lines.
All ratings include the use of a blower time delay relay (TDR). All Lennox variable-speed furnaces and Air Handlers have time delay capabilities. Other Furnaces and Air
Handlers may require an optional time delay relay (58M81) for field installation. See furnace or air handler specifications to determine if relay is needed.
*Most popular combination.
Also see Expansion Valve Kit Usage Table.

13ACX - 1.5 to 5 Ton Air Conditioner / Page 11


AHRI SYSTEM MATCHES
NOTE - For the latest up-to-date system matches please visit the AHRI web site at http://www.ahridirectory.org
Model Coil or AHRI
Capacity SEER EER Furnace
No. Air Handler Reference
13ACX-024-230 + TXV 23,600 14.00 12.00 C33-19 G61MPV-36B-070 3205774
13ACX-024-230 + TXV 23,600 14.00 12.00 C33-19 G61MPV-36B-071 3205706
13ACX-024-230 + TXV 23,600 14.00 12.00 C33-19 G71MPP-36B-070 3205795
13ACX-024-230 + TXV 23,200 13.00 11.00 C33-19 3205681
13ACX-024-230 + TXV 24,000 14.00 12.00 C33-25 G60UHV-36A-070 3205731
13ACX-024-230 + TXV 24,000 14.00 12.00 C33-25 G60UHV-36B-090 3205745
13ACX-024-230 + TXV 24,000 14.00 12.00 C33-25 G61MPV-36B-045 3205759
13ACX-024-230 + TXV 23,800 14.00 12.00 C33-25 G61MPV-36B-070 3205775
13ACX-024-230 + TXV 23,800 14.00 12.00 C33-25 G61MPV-36B-071 3205707
13ACX-024-230 + TXV 23,800 14.00 12.00 C33-25 G71MPP-36B-070 3205796
13ACX-024-230 + TXV 23,400 13.00 11.00 C33-25 3205682
13ACX-024-230 + TXV 23,600 14.00 12.00 C33-30 G60UHV-36A-070 3205732
13ACX-024-230 + TXV 23,600 14.00 12.00 C33-30 G60UHV-36B-090 3205746
13ACX-024-230 + TXV 23,600 14.00 11.50 C33-30 G61MPV-36B-045 3205760
13ACX-024-230 + TXV 23,600 14.00 12.00 C33-30 G61MPV-36B-070 3205776
13ACX-024-230 + TXV 23,600 14.00 12.00 C33-30 G61MPV-36B-071 3205708
13ACX-024-230 + TXV 23,600 14.00 12.00 C33-30 G71MPP-36B-070 3205797
13ACX-024-230 + TXV 23,000 13.00 11.00 C33-30 3205680
13ACX-024-230 + TXV 24,400 14.00 12.00 C33-31 G60UHV-36A-070 3205733
13ACX-024-230 + TXV 24,400 14.00 12.00 C33-31 G60UHV-36B-090 3205747
13ACX-024-230 + TXV 24,400 14.00 12.00 C33-31 G61MPV-36B-045 3205761
13ACX-024-230 + TXV 24,400 14.00 12.00 C33-31 G61MPV-36B-070 3205777
13ACX-024-230 + TXV 24,400 14.00 12.00 C33-31 G61MPV-36B-071 3205709
13ACX-024-230 + TXV 24,400 14.00 12.00 C33-31 G71MPP-36B-070 3205798
13ACX-024-230 + TXV 23,800 13.50 11.00 C33-31 3205683
13ACX-024-230 + TXV 23,800 14.00 12.00 C33-36 G60UHV-36A-070 3205734
13ACX-024-230 + TXV 23,800 14.00 12.00 C33-36 G60UHV-36B-090 3205748
13ACX-024-230 + TXV 23,800 14.00 12.00 C33-36 G61MPV-36B-045 3205762
13ACX-024-230 + TXV 23,800 14.00 12.00 C33-36 G61MPV-36B-070 3205778
13ACX-024-230 + TXV 23,800 14.00 12.00 C33-36 G61MPV-36B-071 3205710
13ACX-024-230 + TXV 23,800 14.00 12.00 C33-36 G71MPP-36B-070 3205799
13ACX-024-230 + TXV 23,400 13.00 11.00 C33-36 3205684
13ACX-024-230 + TXV 24,400 14.00 12.00 C33-38 G60UHV-36A-070 3205735
13ACX-024-230 + TXV 24,400 14.00 12.00 C33-38 G60UHV-36B-090 3205749
13ACX-024-230 + TXV 24,400 14.00 12.00 C33-38 G61MPV-36B-045 3205763
13ACX-024-230 + TXV 24,400 14.00 12.00 C33-38 G61MPV-36B-070 3205779
13ACX-024-230 + TXV 24,400 14.00 12.00 C33-38 G61MPV-36B-071 3205711
13ACX-024-230 + TXV 24,400 14.00 12.00 C33-38 G71MPP-36B-070 3205800
13ACX-024-230 + TXV 24,000 13.50 11.50 C33-38 3205685
13ACX-024-230 + TXV 24,200 14.00 12.00 CB27UH-024-230 3205724
13ACX-024-230 + TXV 24,200 14.00 12.00 CB27UH-030-230 3205725
13ACX-024-230 + TXV 24,000 14.00 11.50 CB30M-31P 3205820
13ACX-024-230 + TXV 25,200 14.00 12.00 CB30M-41P 3205821
13ACX-024-230 + TXV 24,000 14.00 11.50 CBX26UH-024 3205816
13ACX-024-230 + TXV 24,200 14.00 12.00 CBX27UH-024-230 3205726
13ACX-024-230 + TXV 24,200 14.00 12.00 CBX27UH-030-230 3205727
13ACX-024-230 + TXV 23,200 13.50 11.00 CBX32M-018/024 3205823
NOTES:
+ TXV = Matched with Thermostatic Expansion Valve.
+ RFC = Matched with RFC metering device.
Ratings are certified in accordance with USE certification program which is based on AHRI Standard 210/240; 95°F outdoor air temperature, 80°F db / 67°F wb entering
evaporator air with 25 ft. of connecting refrigerant lines.
All ratings include the use of a blower time delay relay (TDR). All Lennox variable-speed furnaces and Air Handlers have time delay capabilities. Other Furnaces and Air
Handlers may require an optional time delay relay (58M81) for field installation. See furnace or air handler specifications to determine if relay is needed.
*Most popular combination.
Also see Expansion Valve Kit Usage Table.

13ACX - 1.5 to 5 Ton Air Conditioner / Page 12


AHRI SYSTEM MATCHES
NOTE - For the latest up-to-date system matches please visit the AHRI web site at http://www.ahridirectory.org
Model Coil or AHRI
Capacity SEER EER Furnace
No. Air Handler Reference
13ACX-024-230 + TXV 24,000 14.00 11.50 CBX32M-030 3205817
13ACX-024-230 + TXV 25,200 14.00 12.00 CBX32M-036 3205818
13ACX-024-230 + TXV 23,600 13.50 11.50 CBX32MV-018/024 3205728
13ACX-024-230 + TXV 23,800 14.00 12.00 CBX32MV-024/030 3205729
13ACX-024-230 + TXV 24,600 14.00 12.00 CBX32MV-036 3205819
13ACX-024-230 + TXV 23,600 13.50 11.50 CBX40UHV-024 3291599
13ACX-024-230 + TXV 23,800 14.00 12.00 CBX40UHV-030 3291613
13ACX-024-230 + TXV 24,600 14.00 12.00 CBX40UHV-036 3291645
13ACX-024-230 + TXV 24,000 14.00 12.00 CH23-41 G60UHV-36A-070 3205736
13ACX-024-230 + TXV 24,000 14.00 12.00 CH23-41 G60UHV-36B-090 3205750
13ACX-024-230 + TXV 24,000 14.00 12.00 CH23-41 G61MPV-36B-045 3205764
13ACX-024-230 + TXV 24,000 14.00 12.00 CH23-41 G61MPV-36B-070 3205780
13ACX-024-230 + TXV 24,000 14.00 12.00 CH23-41 G61MPV-36B-071 3205712
13ACX-024-230 + TXV 24,000 14.00 12.00 CH23-41 G71MPP-36B-070 3205801
13ACX-024-230 + TXV 23,400 13.00 11.00 CH23-41 3205686
13ACX-024-230 + TXV 24,200 14.00 12.00 CH33-25 G60UHV-36A-070 3205696
13ACX-024-230 + TXV 24,200 14.00 12.00 CH33-25 G60UHV-36B-090 3205698
13ACX-024-230 + TXV 24,000 14.00 12.00 CH33-25 G61MPV-36B-045 3205700
13ACX-024-230 + TXV 24,000 14.00 12.00 CH33-25 G61MPV-36B-070 3205702
13ACX-024-230 + TXV 24,000 14.00 12.00 CH33-25 G61MPV-36B-071 3205713
13ACX-024-230 + TXV 24,000 14.00 12.00 CH33-25 G71MPP-36B-070 3205704
13ACX-024-230 + TXV 23,400 13.00 11.00 CH33-25 3205678
13ACX-024-230 + TXV 24,400 14.00 12.00 CH33-31 G60UHV-36A-070 3205697
13ACX-024-230 + TXV 24,600 14.00 12.00 CH33-31 G60UHV-36B-090 3205699
13ACX-024-230 + TXV 24,600 14.00 12.00 CH33-31 G61MPV-36B-045 3205701
13ACX-024-230 + TXV 24,600 14.00 12.00 CH33-31 G61MPV-36B-070 3205703
13ACX-024-230 + TXV 24,600 14.00 12.00 CH33-31 G61MPV-36B-071 3205714
13ACX-024-230 + TXV 24,600 14.00 12.00 CH33-31 G71MPP-36B-070 3205705
13ACX-024-230 + TXV 23,800 13.50 11.00 CH33-31 3205679
13ACX-024-230 + TXV 23,400 13.00 11.00 CH33-36 3205687
13ACX-024-230 + TXV 23,800 14.00 12.00 CH33-36A G60UHV-36A-070 3205737
13ACX-024-230 + TXV 24,000 14.00 12.00 CH33-36B G60UHV-36B-090 3205751
13ACX-024-230 + TXV 23,800 14.00 12.00 CH33-36B G61MPV-36B-045 3205765
13ACX-024-230 + TXV 23,800 14.00 12.00 CH33-36B G61MPV-36B-070 3205781
13ACX-024-230 + TXV 23,800 14.00 12.00 CH33-36B G61MPV-36B-071 3205715
13ACX-024-230 + TXV 23,800 14.00 12.00 CH33-36B G71MPP-36B-070 3205802
13ACX-024-230 + TXV 24,200 14.00 12.00 CH33-36C G61MPV-36C-090 3205790
13ACX-024-230 + TXV 24,200 14.00 12.00 CH33-36C G71MPP-36C-090 3205811
13ACX-024-230 + TXV 23,800 14.00 12.00 CR33-24 G61MPV-36B-045 3205766
13ACX-024-230 + TXV 23,800 14.00 12.00 CR33-24 G61MPV-36B-070 3205782
13ACX-024-230 + TXV 23,800 14.00 12.00 CR33-24 G61MPV-36B-071 3205716
13ACX-024-230 + TXV 23,800 14.00 12.00 CR33-24 G71MPP-36B-070 3205803
13ACX-024-230 + TXV 23,200 13.00 11.00 CR33-24 3205688
13ACX-024-230 + TXV 24,200 14.00 12.00 CR33-30/36 G61MPV-36B-045 3205767
13ACX-024-230 + TXV 24,000 14.00 12.00 CR33-30/36 G61MPV-36B-070 3205783
13ACX-024-230 + TXV 24,000 14.00 12.00 CR33-30/36 G61MPV-36B-071 3205717
13ACX-024-230 + TXV 24,200 14.00 12.00 CR33-30/36 G61MPV-36C-090 3205791
NOTES:
+ TXV = Matched with Thermostatic Expansion Valve.
+ RFC = Matched with RFC metering device.
Ratings are certified in accordance with USE certification program which is based on AHRI Standard 210/240; 95°F outdoor air temperature, 80°F db / 67°F wb entering
evaporator air with 25 ft. of connecting refrigerant lines.
All ratings include the use of a blower time delay relay (TDR). All Lennox variable-speed furnaces and Air Handlers have time delay capabilities. Other Furnaces and Air
Handlers may require an optional time delay relay (58M81) for field installation. See furnace or air handler specifications to determine if relay is needed.
*Most popular combination.
Also see Expansion Valve Kit Usage Table.

13ACX - 1.5 to 5 Ton Air Conditioner / Page 13


AHRI SYSTEM MATCHES
NOTE - For the latest up-to-date system matches please visit the AHRI web site at http://www.ahridirectory.org
Model Coil or AHRI
Capacity SEER EER Furnace
No. Air Handler Reference
13ACX-024-230 + TXV 24,000 14.00 12.00 CR33-30/36 G71MPP-36B-070 3205804
13ACX-024-230 + TXV 24,200 14.00 12.00 CR33-30/36 G71MPP-36C-090 3205812
13ACX-024-230 + TXV 23,600 13.00 11.00 CR33-30/36 3205689
13ACX-024-230 + TXV 23,600 14.00 12.00 CX34-18/24 G60UHV-36A-070 3205738
13ACX-024-230 + TXV 23,600 14.00 12.00 CX34-18/24 G60UHV-36B-090 3205752
13ACX-024-230 + TXV 23,600 14.00 11.50 CX34-18/24 G61MPV-36B-045 3205768
13ACX-024-230 + TXV 23,600 14.00 12.00 CX34-18/24 G61MPV-36B-070 3205784
13ACX-024-230 + TXV 23,600 14.00 12.00 CX34-18/24 G61MPV-36B-071 3205718
13ACX-024-230 + TXV 23,000 14.00 12.00 CX34-18/24 G61MPV-36C-090 3205792
13ACX-024-230 + TXV 23,600 14.00 12.00 CX34-18/24 G71MPP-36B-070 3205805
13ACX-024-230 + TXV 23,000 14.00 12.00 CX34-18/24 G71MPP-36C-090 3205813
13ACX-024-230 + TXV 23,200 13.00 11.00 CX34-18/24 3205695
13ACX-024-230 + TXV 24,000 14.00 12.00 CX34-25 G60UHV-36A-070 3205739
13ACX-024-230 + TXV 24,000 14.00 12.00 CX34-25 G60UHV-36B-090 3205753
13ACX-024-230 + TXV 24,000 14.00 12.00 CX34-25 G61MPV-36B-045 3205769
13ACX-024-230 + TXV 23,800 14.00 12.00 CX34-25 G61MPV-36B-070 3205785
13ACX-024-230 + TXV 23,800 14.00 12.00 CX34-25 G61MPV-36B-071 3205719
13ACX-024-230 + TXV 23,800 14.00 12.00 CX34-25 G71MPP-36B-070 3205806
13ACX-024-230 + TXV 23,400 13.00 11.00 CX34-25 3205690
13ACX-024-230 + TXV 23,600 14.00 12.00 CX34-30 G60UHV-36A-070 3205740
13ACX-024-230 + TXV 23,600 14.00 12.00 CX34-30 G60UHV-36B-090 3205754
13ACX-024-230 + TXV 23,600 14.00 11.50 CX34-30 G61MPV-36B-045 3205770
13ACX-024-230 + TXV 23,600 14.00 12.00 CX34-30 G61MPV-36B-070 3205786
13ACX-024-230 + TXV 23,600 14.00 12.00 CX34-30 G61MPV-36B-071 3205720
13ACX-024-230 + TXV 23,400 14.00 12.00 CX34-30 G61MPV-36C-090 3205793
13ACX-024-230 + TXV 23,600 14.00 12.00 CX34-30 G71MPP-36B-070 3205807
13ACX-024-230 + TXV 23,400 14.00 12.00 CX34-30 G71MPP-36C-090 3205814
13ACX-024-230 + TXV 23,000 13.00 11.00 CX34-30 3205691
13ACX-024-230 + TXV 24,400 14.00 12.00 CX34-31 G60UHV-36A-070 3205741
13ACX-024-230 + TXV 24,400 14.00 12.00 CX34-31 G60UHV-36B-090 3205755
13ACX-024-230 + TXV 24,400 14.00 12.00 CX34-31 G61MPV-36B-045 3205771
13ACX-024-230 + TXV 24,400 14.00 12.00 CX34-31 G61MPV-36B-070 3205787
13ACX-024-230 + TXV 24,400 14.00 12.00 CX34-31 G61MPV-36B-071 3205721
13ACX-024-230 + TXV 24,400 14.00 12.00 CX34-31 G71MPP-36B-070 3205808
13ACX-024-230 + TXV 23,800 13.50 11.00 CX34-31 3205692
13ACX-024-230 + TXV 23,800 14.00 12.00 CX34-36 G60UHV-36A-070 3205742
13ACX-024-230 + TXV 23,800 14.00 12.00 CX34-36 G60UHV-36B-090 3205756
13ACX-024-230 + TXV 23,800 14.00 12.00 CX34-36 G61MPV-36B-045 3205772
13ACX-024-230 + TXV 23,800 14.00 12.00 CX34-36 G61MPV-36B-070 3205788
13ACX-024-230 + TXV 23,800 14.00 12.00 CX34-36 G61MPV-36B-071 3205722
13ACX-024-230 + TXV 24,000 14.00 12.00 CX34-36 G61MPV-36C-090 3205794
13ACX-024-230 + TXV 23,800 14.00 12.00 CX34-36 G71MPP-36B-070 3205809
13ACX-024-230 + TXV 24,000 14.00 12.00 CX34-36 G71MPP-36C-090 3205815
13ACX-024-230 + TXV 23,400 13.00 11.00 CX34-36 3205693
13ACX-024-230 + TXV 24,400 14.00 12.00 CX34-38 G60UHV-36A-070 3205743
13ACX-024-230 + TXV 24,400 14.00 12.00 CX34-38 G60UHV-36B-090 3205757
13ACX-024-230 + TXV 24,400 14.00 12.00 CX34-38 G61MPV-36B-045 3205773
NOTES:
+ TXV = Matched with Thermostatic Expansion Valve.
+ RFC = Matched with RFC metering device.
Ratings are certified in accordance with USE certification program which is based on AHRI Standard 210/240; 95°F outdoor air temperature, 80°F db / 67°F wb entering
evaporator air with 25 ft. of connecting refrigerant lines.
All ratings include the use of a blower time delay relay (TDR). All Lennox variable-speed furnaces and Air Handlers have time delay capabilities. Other Furnaces and Air
Handlers may require an optional time delay relay (58M81) for field installation. See furnace or air handler specifications to determine if relay is needed.
*Most popular combination.
Also see Expansion Valve Kit Usage Table.

13ACX - 1.5 to 5 Ton Air Conditioner / Page 14


AHRI SYSTEM MATCHES
NOTE - For the latest up-to-date system matches please visit the AHRI web site at http://www.ahridirectory.org
Model Coil or AHRI
Capacity SEER EER Furnace
No. Air Handler Reference
13ACX-024-230 + TXV 24,400 14.00 12.00 CX34-38 G61MPV-36B-070 3205789
13ACX-024-230 + TXV 24,400 14.00 12.00 CX34-38 G61MPV-36B-071 3205723
13ACX-024-230 + TXV 24,400 14.00 12.00 CX34-38 G71MPP-36B-070 3205810
13ACX-024-230 + TXV 24,000 13.50 11.50 CX34-38 3205694
13ACX-030-230 + RFC 28,200 14.00 11.50 C33-19 G60UHV-36A-070 3231421
13ACX-030-230 + RFC 28,000 14.00 11.50 C33-19 G60UHV-36B-090 3231428
13ACX-030-230 + RFC 28,600 13.50 11.50 C33-19 G61MPV-36B-045 3231437
13ACX-030-230 + RFC 28,400 13.50 11.50 C33-19 G61MPV-36B-070 3231445
13ACX-030-230 + RFC 28,400 13.50 11.50 C33-19 G71MPP-36B-070 3231451
13ACX-030-230 + RFC 29,000 14.00 12.00 C33-25 G60UHV-36A-070 3231422
13ACX-030-230 + RFC 29,200 14.00 12.00 C33-25 G60UHV-36B-090 3231429
13ACX-030-230 + RFC 29,200 14.00 11.50 C33-25 G61MPV-36B-045 3231438
13ACX-030-230 + RFC 29,000 14.00 11.50 C33-25 G61MPV-36B-070 3231446
13ACX-030-230 + RFC 29,000 14.00 11.50 C33-25 G71MPP-36B-070 3231452
13ACX-030-230 + RFC 28,800 13.00 11.00 C33-25 3231395
13ACX-030-230 + RFC 29,600 14.00 12.00 C33-31 G60UHV-36A-070 3231423
13ACX-030-230 + RFC 29,600 14.00 12.00 C33-31 G60UHV-36B-090 3231430
13ACX-030-230 + RFC 29,800 14.00 12.00 C33-31 G61MPV-36B-045 3231439
13ACX-030-230 + RFC 29,600 14.00 12.00 C33-31 G61MPV-36B-070 3231447
13ACX-030-230 + RFC 29,600 14.00 12.00 C33-31 G71MPP-36B-070 3231453
13ACX-030-230 + RFC 29,400 13.00 11.00 C33-31 3231396
13ACX-030-230 + RFC 29,000 14.00 12.00 C33-36 G60UHV-36A-070 3231424
13ACX-030-230 + RFC 28,800 14.00 12.00 C33-36 G60UHV-36B-090 3231431
13ACX-030-230 + RFC 28,600 14.00 11.50 C33-36 G61MPV-36B-045 3231440
13ACX-030-230 + RFC 28,600 14.00 12.00 C33-36 G61MPV-36B-070 3231448
13ACX-030-230 + RFC 28,600 14.00 12.00 C33-36 G71MPP-36B-070 3231454
13ACX-030-230 + RFC 28,400 13.00 11.00 C33-36 3231397
13ACX-030-230 + RFC 29,800 14.00 12.00 C33-38 G60UHV-36A-070 3231425
13ACX-030-230 + RFC 29,600 13.50 11.00 C33-38 3231398
13ACX-030-230 + RFC 28,800 14.00 12.00 C33-42 G60UHV-36B-090 3231461
13ACX-030-230 + RFC 28,600 14.00 11.50 C33-42 G61MPV-36B-045 3231457
13ACX-030-230 + RFC 28,600 14.00 12.00 C33-42 G61MPV-36B-070 3231458
13ACX-030-230 + RFC 28,600 14.00 12.00 C33-42 G71MPP-36B-070 3231460
13ACX-030-230 + RFC 28,600 13.00 11.00 C33-42 3231403
13ACX-030-230 + RFC 30,000 14.00 12.00 C33-43 G60UHV-36B-090 3231432
13ACX-030-230 + RFC 30,200 14.00 12.00 C33-43 G61MPV-36B-045 3231441
13ACX-030-230 + RFC 30,000 14.00 12.00 C33-43 G61MPV-36B-070 3231409
13ACX-030-230 + RFC 30,000 14.00 12.00 C33-43 G71MPP-36B-070 3231414
13ACX-030-230 + RFC 29,800 13.50 11.00 C33-43 3231399
13ACX-030-230 + RFC 29,000 14.00 12.00 CH23-41 G60UHV-36A-070 3231426
13ACX-030-230 + RFC 28,800 14.00 12.00 CH23-41 G60UHV-36B-090 3231433
13ACX-030-230 + RFC 28,800 13.50 11.50 CH23-41 G61MPV-36B-045 3231406
13ACX-030-230 + RFC 29,000 14.00 12.00 CH23-41 G61MPV-36B-070 3231410
13ACX-030-230 + RFC 29,000 14.00 12.00 CH23-41 G71MPP-36B-070 3231415
13ACX-030-230 + RFC 29,000 14.00 11.50 CH33-25 G60UHV-36A-070 3231404
13ACX-030-230 + RFC 29,000 14.00 12.00 CH33-25 G60UHV-36B-090 3231405
13ACX-030-230 + RFC 28,600 13.50 11.50 CH33-25 G61MPV-36B-045 3231407
NOTES:
+ TXV = Matched with Thermostatic Expansion Valve.
+ RFC = Matched with RFC metering device.
Ratings are certified in accordance with USE certification program which is based on AHRI Standard 210/240; 95°F outdoor air temperature, 80°F db / 67°F wb entering
evaporator air with 25 ft. of connecting refrigerant lines.
All ratings include the use of a blower time delay relay (TDR). All Lennox variable-speed furnaces and Air Handlers have time delay capabilities. Other Furnaces and Air
Handlers may require an optional time delay relay (58M81) for field installation. See furnace or air handler specifications to determine if relay is needed.
*Most popular combination.
Also see Expansion Valve Kit Usage Table.

13ACX - 1.5 to 5 Ton Air Conditioner / Page 15


AHRI SYSTEM MATCHES
NOTE - For the latest up-to-date system matches please visit the AHRI web site at http://www.ahridirectory.org
Model Coil or AHRI
Capacity SEER EER Furnace
No. Air Handler Reference
13ACX-030-230 + RFC 28,800 14.00 11.50 CH33-25 G61MPV-36B-070 3231411
13ACX-030-230 + RFC 28,600 14.00 11.50 CH33-25 G61MPV-36B-071 3231419
13ACX-030-230 + RFC 28,800 14.00 11.50 CH33-25 G71MPP-36B-070 3231416
13ACX-030-230 + RFC 28,600 13.00 11.00 CH33-25 3231393
13ACX-030-230 + RFC 29,600 14.00 12.00 CH33-31 G60UHV-36A-070 3231459
13ACX-030-230 + RFC 30,000 14.00 12.50 CH33-31 G60UHV-36B-090 3231434
13ACX-030-230 + RFC 29,600 14.00 11.50 CH33-31 G61MPV-36B-045 3231408
13ACX-030-230 + RFC 29,800 14.00 12.00 CH33-31 G61MPV-36B-070 3231412
13ACX-030-230 + RFC 29,800 14.00 12.00 CH33-31 G71MPP-36B-070 3231417
13ACX-030-230 + RFC 29,200 13.50 11.00 CH33-31 3231394
13ACX-030-230 + RFC 29,000 14.00 11.50 CH33-36 G60UHV-36A-070 3231427
13ACX-030-230 + RFC 28,800 14.00 12.00 CH33-36 G60UHV-36B-090 3231435
13ACX-030-230 + RFC 28,800 13.50 11.50 CH33-36 G61MPV-36B-045 3231442
13ACX-030-230 + RFC 29,000 14.00 11.50 CH33-36 G61MPV-36B-070 3231449
13ACX-030-230 + RFC 29,000 14.00 11.50 CH33-36 G71MPP-36B-070 3231455
13ACX-030-230 + RFC 28,600 13.00 11.00 CH33-36 3231400
13ACX-030-230 + RFC 29,600 14.00 12.00 CH33-42 G60UHV-36B-090 3231436
13ACX-030-230 + RFC 29,400 14.00 12.00 CH33-42 G61MPV-36B-045 3231443
13ACX-030-230 + RFC 29,400 14.00 12.00 CH33-42 G61MPV-36B-070 3231450
13ACX-030-230 + RFC 29,400 14.00 12.00 CH33-42 G71MPP-36B-070 3231456
13ACX-030-230 + RFC 29,200 13.00 11.00 CH33-42 3231401
13ACX-030-230 + RFC 29,400 14.00 12.00 CR33-30/36 G60DFV-36B-090 3231420
13ACX-030-230 + RFC 29,000 14.00 12.00 CR33-30/36 G61MPV-36B-045 3231444
13ACX-030-230 + RFC 29,000 14.00 12.00 CR33-30/36 G61MPV-36B-070 3231413
13ACX-030-230 + RFC 29,000 14.00 12.00 CR33-30/36 G71MPP-36B-070 3231418
13ACX-030-230 + RFC 28,800 13.00 11.00 CR33-30/36 3231402
13ACX-030-230 + TXV 29,800 14.00 12.00 CB27UH-030-230 3205934
13ACX-030-230 + TXV 29,800 14.00 12.00 CB27UH-036-230 3205935
13ACX-030-230 + TXV 27,800 13.00 11.00 CB30M-21/26P 3205943
13ACX-030-230 + TXV 30,400 14.00 12.50 CB30M-31P 3205944
13ACX-030-230 + TXV 30,400 14.00 12.50 CB30M-41P 3205945
13ACX-030-230 + TXV 29,200 14.00 12.00 CBX26UH-030 3205939
13ACX-030-230 + TXV 29,800 14.00 12.00 CBX27UH-030-230 3205936
13ACX-030-230 + TXV 29,800 14.00 12.00 CBX27UH-036-230 3205937
13ACX-030-230 + TXV 27,800 13.00 11.00 CBX32M-018/024 3205940
13ACX-030-230 + TXV 30,400 14.00 12.50 CBX32M-030 3205938
13ACX-030-230 + TXV 30,400 14.00 12.50 CBX32M-036 3205941
13ACX-030-230 + TXV 29,400 14.00 12.00 CBX32MV-024/030 3205942
13ACX-030-230 + TXV 29,400 14.00 12.50 CBX32MV-036 3205864
13ACX-030-230 + TXV 29,400 14.00 12.00 CBX40UHV-030 3291615
13ACX-030-230 + TXV 29,400 14.00 12.50 CBX40UHV-036 3291647
13ACX-030-230 + TXV 29,000 14.00 12.00 CH23-41 G60UHV-36A-070 3205841
13ACX-030-230 + TXV 29,200 14.00 12.50 CH23-41 G60UHV-36B-090 3205873
13ACX-030-230 + TXV 29,200 14.00 12.00 CH23-41 G61MPV-36B-045 3205885
13ACX-030-230 + TXV 29,000 14.00 12.00 CH23-41 G61MPV-36B-070 3205895
13ACX-030-230 + TXV 30,000 14.00 12.00 CH23-41 G61MPV-36B-071 3205906
13ACX-030-230 + TXV 29,000 14.00 12.00 CH23-41 G71MPP-36B-070 3205922
NOTES:
+ TXV = Matched with Thermostatic Expansion Valve.
+ RFC = Matched with RFC metering device.
Ratings are certified in accordance with USE certification program which is based on AHRI Standard 210/240; 95°F outdoor air temperature, 80°F db / 67°F wb entering
evaporator air with 25 ft. of connecting refrigerant lines.
All ratings include the use of a blower time delay relay (TDR). All Lennox variable-speed furnaces and Air Handlers have time delay capabilities. Other Furnaces and Air
Handlers may require an optional time delay relay (58M81) for field installation. See furnace or air handler specifications to determine if relay is needed.
*Most popular combination.
Also see Expansion Valve Kit Usage Table.

13ACX - 1.5 to 5 Ton Air Conditioner / Page 16


AHRI SYSTEM MATCHES
NOTE - For the latest up-to-date system matches please visit the AHRI web site at http://www.ahridirectory.org
Model Coil or AHRI
Capacity SEER EER Furnace
No. Air Handler Reference
13ACX-030-230 + TXV 28,800 13.50 11.00 CH23-41 3205824
13ACX-030-230 + TXV 28,600 14.00 12.00 CH33-19 G60UHV-36A-070 3205842
13ACX-030-230 + TXV 28,400 13.00 11.00 CH33-19 3205825
13ACX-030-230 + TXV 29,400 14.00 12.00 CH33-25 G60UHV-36A-070 3205867
13ACX-030-230 + TXV 29,400 14.00 12.50 CH33-25 G60UHV-36B-090 3205874
13ACX-030-230 + TXV 30,200 14.00 12.00 CH33-25 G61MPV-36B-045 3205849
13ACX-030-230 + TXV 29,400 14.00 12.00 CH33-25 G61MPV-36B-070 3205896
13ACX-030-230 + TXV 30,000 14.00 12.00 CH33-25 G61MPV-36B-071 3205907
13ACX-030-230 + TXV 29,400 14.00 12.00 CH33-25 G71MPP-36B-070 3205923
13ACX-030-230 + TXV 29,200 13.50 11.50 CH33-25 3205826
13ACX-030-230 + TXV 29,800 14.00 12.50 CH33-31 G60UHV-36A-070 3205843
13ACX-030-230 + TXV 30,200 14.00 12.50 CH33-31 G60UHV-36B-090 3205875
13ACX-030-230 + TXV 29,800 14.00 12.50 CH33-31 G61MPV-36B-045 3205886
13ACX-030-230 + TXV 30,200 14.00 12.50 CH33-31 G61MPV-36B-070 3205897
13ACX-030-230 + TXV 31,000 14.00 12.50 CH33-31 G61MPV-36B-071 3205859
13ACX-030-230 + TXV 30,200 14.00 12.50 CH33-31 G71MPP-36B-070 3205924
13ACX-030-230 + TXV 29,800 13.50 11.50 CH33-31 3205827
13ACX-030-230 + TXV 29,000 14.00 12.50 CH33-36 G60UHV-36B-090 3205876
13ACX-030-230 + TXV 29,000 14.00 12.00 CH33-36 G61MPV-36B-045 3205850
13ACX-030-230 + TXV 28,600 13.00 11.00 CH33-36 3205828
13ACX-030-230 + TXV 28,800 14.00 12.00 CH33-36A G60UHV-36A-070 3205868
13ACX-030-230 + TXV 28,800 14.00 12.00 CH33-36B G61MPV-36B-070 3205898
13ACX-030-230 + TXV 29,800 14.00 12.00 CH33-36B G61MPV-36B-071 3205908
13ACX-030-230 + TXV 28,800 14.00 12.00 CH33-36B G71MPP-36B-070 3205925
13ACX-030-230 + TXV 29,600 14.50 12.50 CH33-36C G61MPV-36C-090 3205921
13ACX-030-230 + TXV 29,600 14.50 12.50 CH33-36C G71MPP-36C-090 3205933
13ACX-030-230 + TXV 29,600 14.00 12.50 CH33-42 G60UHV-36B-090 3205877
13ACX-030-230 + TXV 29,600 14.00 12.00 CH33-42 G61MPV-36B-045 3205887
13ACX-030-230 + TXV 29,400 14.00 12.00 CH33-42 G61MPV-36B-070 3205899
13ACX-030-230 + TXV 30,600 14.00 12.00 CH33-42 G61MPV-36B-071 3205909
13ACX-030-230 + TXV 29,400 14.00 12.00 CH33-42 G71MPP-36B-070 3205926
13ACX-030-230 + TXV 29,200 13.50 11.50 CH33-42 3205829
13ACX-030-230 + TXV 28,800 14.00 12.00 CR33-24 G60DFV-36B-090 3205865
13ACX-030-230 + TXV 28,800 14.00 11.50 CR33-24 G61MPV-36B-045 3205851
13ACX-030-230 + TXV 28,600 14.00 12.00 CR33-24 G61MPV-36B-070 3205855
13ACX-030-230 + TXV 29,400 14.00 12.00 CR33-24 G61MPV-36B-071 3205910
13ACX-030-230 + TXV 28,600 14.00 12.00 CR33-24 G71MPP-36B-070 3205860
13ACX-030-230 + TXV 28,400 13.00 11.00 CR33-24 3205830
13ACX-030-230 + TXV 29,400 14.00 12.50 CR33-30/36 G60DFV-36B-090 3205866
13ACX-030-230 + TXV 29,200 14.00 12.00 CR33-30/36 G61MPV-36B-045 3205888
13ACX-030-230 + TXV 29,000 14.00 12.00 CR33-30/36 G61MPV-36B-070 3205900
13ACX-030-230 + TXV 30,400 14.50 12.50 CR33-30/36 G61MPV-36B-071 3205911
13ACX-030-230 + TXV 29,000 14.00 12.00 CR33-30/36 G71MPP-36B-070 3205927
13ACX-030-230 + TXV 29,000 13.50 11.50 CR33-30/36 3205831
13ACX-030-230 + TXV 28,000 13.50 11.50 CX34-18/24 G60UHV-36A-070 3205869
13ACX-030-230 + TXV 28,200 13.50 11.50 CX34-18/24 G60UHV-36B-090 3205878
13ACX-030-230 + TXV 28,400 13.00 11.00 CX34-18/24 G61MPV-36B-045 3205889
NOTES:
+ TXV = Matched with Thermostatic Expansion Valve.
+ RFC = Matched with RFC metering device.
Ratings are certified in accordance with USE certification program which is based on AHRI Standard 210/240; 95°F outdoor air temperature, 80°F db / 67°F wb entering
evaporator air with 25 ft. of connecting refrigerant lines.
All ratings include the use of a blower time delay relay (TDR). All Lennox variable-speed furnaces and Air Handlers have time delay capabilities. Other Furnaces and Air
Handlers may require an optional time delay relay (58M81) for field installation. See furnace or air handler specifications to determine if relay is needed.
*Most popular combination.
Also see Expansion Valve Kit Usage Table.

13ACX - 1.5 to 5 Ton Air Conditioner / Page 17


AHRI SYSTEM MATCHES
NOTE - For the latest up-to-date system matches please visit the AHRI web site at http://www.ahridirectory.org
Model Coil or AHRI
Capacity SEER EER Furnace
No. Air Handler Reference
13ACX-030-230 + TXV 28,400 14.00 12.00 CX34-18/24 G61MPV-36B-070 3205856
13ACX-030-230 + TXV 28,000 13.50 11.50 CX34-18/24 G61MPV-36B-071 3205912
13ACX-030-230 + TXV 28,400 14.00 12.00 CX34-18/24 G71MPP-36B-070 3205861
13ACX-030-230 + TXV 28,600 13.00 11.00 CX34-18/24 3205838
13ACX-030-230 + TXV 28,400 14.00 12.00 CX34-19 G60UHV-36A-070 3205844
13ACX-030-230 + TXV 28,600 14.00 12.00 CX34-19 G60UHV-36B-090 3205847
13ACX-030-230 + TXV 28,600 14.00 11.50 CX34-19 G61MPV-36B-045 3205852
13ACX-030-230 + TXV 29,600 14.00 12.00 CX34-19 G61MPV-36B-071 3205913
13ACX-030-230 + TXV 29,200 13.00 11.00 CX34-19 3205837
13ACX-030-230 + TXV 28,800 14.00 12.00 CX34-25 G60UHV-36A-070 3205845
13ACX-030-230 + TXV 29,000 14.00 12.50 CX34-25 G60UHV-36B-090 3205879
13ACX-030-230 + TXV 29,000 14.00 12.00 CX34-25 G61MPV-36B-045 3205890
13ACX-030-230 + TXV 28,800 14.00 12.00 CX34-25 G61MPV-36B-070 3205901
13ACX-030-230 + TXV 30,200 14.00 12.00 CX34-25 G61MPV-36B-071 3205914
13ACX-030-230 + TXV 28,800 14.00 12.00 CX34-25 G71MPP-36B-070 3205928
13ACX-030-230 + TXV 30,000 13.50 11.50 CX34-25 3205833
13ACX-030-230 + TXV 28,600 14.00 12.00 CX34-30 G60UHV-36A-070 3205870
13ACX-030-230 + TXV 28,600 14.00 12.00 CX34-30 G60UHV-36B-090 3205880
13ACX-030-230 + TXV 28,600 13.50 11.50 CX34-30 G61MPV-36B-045 3205853
13ACX-030-230 + TXV 28,400 14.00 11.50 CX34-30 G61MPV-36B-070 3205902
13ACX-030-230 + TXV 29,000 14.00 11.60 CX34-30 G61MPV-36B-071 3205915
13ACX-030-230 + TXV 28,400 14.00 11.50 CX34-30 G71MPP-36B-070 3205929
13ACX-030-230 + TXV 28,800 13.00 11.00 CX34-30 3205832
13ACX-030-230 + TXV 29,600 14.00 12.50 CX34-31 G60UHV-36A-070 3205871
13ACX-030-230 + TXV 29,600 14.00 12.50 CX34-31 G60UHV-36B-090 3205848
13ACX-030-230 + TXV 29,600 14.00 12.00 CX34-31 G61MPV-36B-045 3205891
13ACX-030-230 + TXV 29,600 14.00 12.50 CX34-31 G61MPV-36B-070 3205903
13ACX-030-230 + TXV 30,800 14.00 12.50 CX34-31 G61MPV-36B-071 3205916
13ACX-030-230 + TXV 29,600 14.00 12.50 CX34-31 G71MPP-36B-070 3205930
13ACX-030-230 + TXV 30,400 13.50 11.50 CX34-31 3205834
13ACX-030-230 + TXV 28,800 14.00 12.00 CX34-36 G60UHV-36A-070 3205872
13ACX-030-230 + TXV 28,800 14.00 12.00 CX34-36 G60UHV-36B-090 3205881
13ACX-030-230 + TXV 28,800 14.00 12.00 CX34-36 G61MPV-36B-045 3205892
13ACX-030-230 + TXV 28,800 14.00 12.00 CX34-36 G61MPV-36B-070 3205904
13ACX-030-230 + TXV 30,000 14.00 12.00 CX34-36 G61MPV-36B-071 3205917
13ACX-030-230 + TXV 28,800 14.00 12.00 CX34-36 G71MPP-36B-070 3205931
13ACX-030-230 + TXV 29,600 13.00 11.50 CX34-36 3205836
13ACX-030-230 + TXV 29,800 14.00 12.50 CX34-38 G60UHV-36A-070 3205846
13ACX-030-230 + TXV 29,800 14.00 12.50 CX34-38 G60UHV-36B-090 3205882
13ACX-030-230 + TXV 29,800 14.00 12.00 CX34-38 G61MPV-36B-045 3205854
13ACX-030-230 + TXV 29,800 14.00 12.50 CX34-38 G61MPV-36B-070 3205857
13ACX-030-230 + TXV 31,000 14.00 12.50 CX34-38 G61MPV-36B-071 3205918
13ACX-030-230 + TXV 29,800 14.00 12.50 CX34-38 G71MPP-36B-070 3205862
13ACX-030-230 + TXV 30,800 13.50 11.50 CX34-38 3205835
13ACX-030-230 + TXV 28,800 14.00 12.00 CX34-42 G60UHV-36B-090 3205883
13ACX-030-230 + TXV 28,800 14.00 12.00 CX34-42 G61MPV-36B-045 3205893
13ACX-030-230 + TXV 28,800 14.00 12.00 CX34-42 G61MPV-36B-070 3205905
NOTES:
+ TXV = Matched with Thermostatic Expansion Valve.
+ RFC = Matched with RFC metering device.
Ratings are certified in accordance with USE certification program which is based on AHRI Standard 210/240; 95°F outdoor air temperature, 80°F db / 67°F wb entering
evaporator air with 25 ft. of connecting refrigerant lines.
All ratings include the use of a blower time delay relay (TDR). All Lennox variable-speed furnaces and Air Handlers have time delay capabilities. Other Furnaces and Air
Handlers may require an optional time delay relay (58M81) for field installation. See furnace or air handler specifications to determine if relay is needed.
*Most popular combination.
Also see Expansion Valve Kit Usage Table.

13ACX - 1.5 to 5 Ton Air Conditioner / Page 18


AHRI SYSTEM MATCHES
NOTE - For the latest up-to-date system matches please visit the AHRI web site at http://www.ahridirectory.org
Model Coil or AHRI
Capacity SEER EER Furnace
No. Air Handler Reference
13ACX-030-230 + TXV 30,000 14.00 12.00 CX34-42 G61MPV-36B-071 3205919
13ACX-030-230 + TXV 28,800 14.00 12.00 CX34-42 G71MPP-36B-070 3205932
13ACX-030-230 + TXV 29,600 13.00 11.50 CX34-42 3205839
13ACX-030-230 + TXV 30,000 14.00 12.50 CX34-43 G60UHV-36B-090 3205884
13ACX-030-230 + TXV 30,000 14.00 12.00 CX34-43 G61MPV-36B-045 3205894
13ACX-030-230 + TXV 29,800 14.00 12.50 CX34-43 G61MPV-36B-070 3205858
13ACX-030-230 + TXV 31,200 14.00 12.50 CX34-43 G61MPV-36B-071 3205920
13ACX-030-230 + TXV 29,800 14.00 12.50 CX34-43 G71MPP-36B-070 3205863
13ACX-030-230 + TXV 31,000 13.50 11.50 CX34-43 3205840
13ACX-036-230 + RFC 34,800 13.50 11.50 C33-38 G60UHV-36A-070 3470058
13ACX-036-230 + RFC 35,400 14.00 11.50 C33-38 G60UHV-36B-090 3470059
13ACX-036-230 + RFC 34,800 13.50 11.50 C33-38 G61MPV-36B-045 3470060
13ACX-036-230 + RFC 34,600 14.00 11.50 C33-38 G61MPV-36B-070 3470061
13ACX-036-230 + RFC 34,600 14.00 11.50 C33-38 G71MPP-36B-070 3470062
13ACX-036-230 + RFC 34,600 13.00 11.00 C33-38 3470063
13ACX-036-230 + RFC 35,600 14.00 12.00 C33-43 G60UHV-36B-090 3470064
13ACX-036-230 + RFC 34,600 14.00 11.50 C33-43 G61MPV-36B-045 3470065
13ACX-036-230 + RFC 35,200 14.00 11.50 C33-43 G61MPV-36B-070 3470066
13ACX-036-230 + RFC 35,200 14.00 11.50 C33-43 G71MPP-36B-070 3470067
13ACX-036-230 + RFC 34,800 13.00 11.00 C33-43 3470068
13ACX-036-230 + RFC 35,600 14.50 12.00 C33-50/60C G60UHV-60C-110 3470069
13ACX-036-230 + RFC 35,400 14.00 11.50 C33-50/60C G61MPV-60C-090 3470070
13ACX-036-230 + RFC 35,600 14.00 11.50 C33-50/60C G61MPV-60C-110 3470071
13ACX-036-230 + RFC 35,400 14.00 11.50 C33-50/60C G71MPP-60C-090 3470072
13ACX-036-230 + RFC 35,600 14.00 11.50 C33-50/60C G71MPP-60C-110 3470073
13ACX-036-230 + RFC 34,800 13.00 11.00 C33-50/60C 3470074
13ACX-036-230 + RFC 34,000 14.00 11.50 CH23-41 G60UHV-36B-090 3470075
13ACX-036-230 + RFC 33,800 13.00 11.00 CH23-41 G61MPV-36B-045 3470076
13ACX-036-230 + RFC 33,800 13.50 11.00 CH23-41 G61MPV-36B-070 3470077
13ACX-036-230 + RFC 33,800 13.50 11.00 CH23-41 G71MPP-36B-070 3470078
13ACX-036-230 + RFC 34,200 14.00 11.50 CH23-51 G60UHV-36B-090 3470079
13ACX-036-230 + RFC 34,000 13.00 11.00 CH23-51 G61MPV-36B-045 3470080
13ACX-036-230 + RFC 33,800 13.00 11.00 CH23-51 G61MPV-36B-070 3470081
13ACX-036-230 + RFC 33,800 13.00 11.00 CH23-51 G71MPP-36B-070 3470082
13ACX-036-230 + RFC 35,400 14.50 12.00 CH33-43 G60UHV-36B-090 3470083
13ACX-036-230 + RFC 35,000 14.00 11.50 CH33-43 G61MPV-36B-045 3470084
13ACX-036-230 + RFC 35,600 14.00 11.50 CH33-43 G61MPV-36B-070 3470085
13ACX-036-230 + RFC 35,400 14.00 11.50 CH33-43 G61MPV-36B-071 3470086
13ACX-036-230 + RFC 35,400 14.50 12.00 CH33-43 G61MPV-36C-090 3470089
13ACX-036-230 + RFC 35,600 14.00 11.50 CH33-43 G71MPP-36B-070 3470087
13ACX-036-230 + RFC 35,400 14.50 12.00 CH33-43 G71MPP-36C-090 3470090
13ACX-036-230 + RFC 35,400 13.50 11.00 CH33-43 3470088
13ACX-036-230 + RFC 35,200 14.00 11.50 CH33-44/48 G60UHV-36B-090 3470091
13ACX-036-230 + RFC 34,800 13.50 11.00 CH33-44/48 G61MPV-36B-045 3470092
13ACX-036-230 + RFC 34,800 13.50 11.00 CH33-44/48 G61MPV-36B-070 3470093
13ACX-036-230 + RFC 34,800 13.50 11.00 CH33-44/48 G71MPP-36B-070 3470094
13ACX-036-230 + RFC 34,600 13.00 11.00 CH33-44/48 3470095
NOTES:
+ TXV = Matched with Thermostatic Expansion Valve.
+ RFC = Matched with RFC metering device.
Ratings are certified in accordance with USE certification program which is based on AHRI Standard 210/240; 95°F outdoor air temperature, 80°F db / 67°F wb entering
evaporator air with 25 ft. of connecting refrigerant lines.
All ratings include the use of a blower time delay relay (TDR). All Lennox variable-speed furnaces and Air Handlers have time delay capabilities. Other Furnaces and Air
Handlers may require an optional time delay relay (58M81) for field installation. See furnace or air handler specifications to determine if relay is needed.
*Most popular combination.
Also see Expansion Valve Kit Usage Table.

13ACX - 1.5 to 5 Ton Air Conditioner / Page 19


AHRI SYSTEM MATCHES
NOTE - For the latest up-to-date system matches please visit the AHRI web site at http://www.ahridirectory.org
Model Coil or AHRI
Capacity SEER EER Furnace
No. Air Handler Reference
13ACX-036-230 + RFC 35,600 14.00 11.50 CH33-48 G61MPV-60C-090 3470096
13ACX-036-230 + RFC 35,600 14.00 11.50 CH33-48 G61MPV-60C-110 3470097
13ACX-036-230 + RFC 35,600 14.00 11.50 CH33-48 G71MPP-60C-090 3470098
13ACX-036-230 + RFC 35,600 14.00 11.50 CH33-48 G71MPP-60C-110 3470099
13ACX-036-230 + RFC 34,400 13.00 11.00 CH33-48 3470100
13ACX-036-230 + RFC 33,800 13.50 11.50 CR33-48 G60DFV-36B-090 3470101
13ACX-036-230 + RFC 33,400 13.00 11.00 CR33-48 G61MPV-36B-045 3470102
13ACX-036-230 + RFC 33,400 13.00 11.00 CR33-48 G61MPV-36B-070 3470103
13ACX-036-230 + RFC 33,800 13.00 11.00 CR33-48 G61MPV-60C-090 3470107
13ACX-036-230 + RFC 33,800 13.50 11.00 CR33-48 G61MPV-60C-110 3470108
13ACX-036-230 + RFC 33,400 13.00 11.00 CR33-48 G71MPP-36B-070 3470104
13ACX-036-230 + RFC 33,800 13.00 11.00 CR33-48 G71MPP-60C-090 3470109
13ACX-036-230 + RFC 33,800 13.50 11.00 CR33-48 G71MPP-60C-110 3470110
13ACX-036-230 + RFC 34,000 13.00 10.95 CR33-50/60 3470105
13ACX-036-230 + TXV 35,400 14.00 11.50 C33-38 G60UHV-36B-090 3469958
13ACX-036-230 + TXV 34,600 13.50 11.50 C33-38 G61MPV-36B-045 3469959
13ACX-036-230 + TXV 34,600 13.50 11.50 C33-38 G61MPV-36B-070 3469960
13ACX-036-230 + TXV 34,200 14.00 11.50 C33-38 G61MPV-36B-071 3469961
13ACX-036-230 + TXV 34,600 13.50 11.50 C33-38 G71MPP-36B-070 3469962
13ACX-036-230 + TXV 34,600 13.00 11.00 C33-38 3469963
13ACX-036-230 + TXV 35,600 14.50 12.00 C33-43 G60UHV-36B-090 3469964
13ACX-036-230 + TXV 34,400 14.00 11.50 C33-43 G61MPV-36B-045 3469965
13ACX-036-230 + TXV 34,800 14.00 11.50 C33-43 G61MPV-36B-070 3469966
13ACX-036-230 + TXV 34,400 14.00 11.50 C33-43 G61MPV-36B-071 3469967
13ACX-036-230 + TXV 34,800 14.00 11.50 C33-43 G71MPP-36B-070 3469968
13ACX-036-230 + TXV 34,800 13.00 11.00 C33-43 3469969
13ACX-036-230 + TXV 35,600 14.00 12.00 C33-50/60C G60UHV-60C-110 3469970
13ACX-036-230 + TXV 35,400 14.00 11.50 C33-50/60C G61MPV-60C-090 3469971
13ACX-036-230 + TXV 35,600 14.00 12.00 C33-50/60C G61MPV-60C-110 3469972
13ACX-036-230 + TXV 35,600 14.00 12.00 C33-50/60C G61MPV-60C-111 3469973
13ACX-036-230 + TXV 35,000 14.00 11.50 C33-50/60C G71MPP-36C-090 3469974
13ACX-036-230 + TXV 35,600 14.00 12.00 C33-50/60C G71MPP-60C-110 3469975
13ACX-036-230 + TXV 34,600 13.00 11.00 C33-50/60C 3469976
13ACX-036-230 + TXV 34,600 14.00 11.50 CB27UH-036-230 3469977
13ACX-036-230 + TXV 35,600 14.50 12.00 CB27UH-042-230 3469978
13ACX-036-230 + TXV 33,800 13.00 11.00 CB30M-31P 3469979
13ACX-036-230 + TXV 34,200 13.00 11.00 CB30M-41P 3469980
13ACX-036-230 + TXV 34,200 13.00 11.00 CB30M-46P 3469981
13ACX-036-230 + TXV 35,200 13.50 11.50 CB30M-51P 3469982
13ACX-036-230 + TXV 34,200 13.00 11.00 CBX26UH-036 3469985
13ACX-036-230 + TXV 34,600 14.00 11.50 CBX27UH-036-230 3469986
13ACX-036-230 + TXV 35,600 14.50 12.00 CBX27UH-042-230 3469987
13ACX-036-230 + TXV 33,800 13.00 11.00 CBX32M-030 3469988
13ACX-036-230 + TXV 34,200 13.00 11.00 CBX32M-036 3469989
13ACX-036-230 + TXV 34,200 13.00 11.00 CBX32M-042 3469990
13ACX-036-230 + TXV 35,200 13.50 11.50 CBX32M-048 3469991
13ACX-036-230 + TXV 34,400 14.00 11.50 CBX32MV-036 3469992
NOTES:
+ TXV = Matched with Thermostatic Expansion Valve.
+ RFC = Matched with RFC metering device.
Ratings are certified in accordance with USE certification program which is based on AHRI Standard 210/240; 95°F outdoor air temperature, 80°F db / 67°F wb entering
evaporator air with 25 ft. of connecting refrigerant lines.
All ratings include the use of a blower time delay relay (TDR). All Lennox variable-speed furnaces and Air Handlers have time delay capabilities. Other Furnaces and Air
Handlers may require an optional time delay relay (58M81) for field installation. See furnace or air handler specifications to determine if relay is needed.
*Most popular combination.
Also see Expansion Valve Kit Usage Table.

13ACX - 1.5 to 5 Ton Air Conditioner / Page 20


AHRI SYSTEM MATCHES
NOTE - For the latest up-to-date system matches please visit the AHRI web site at http://www.ahridirectory.org
Model Coil or AHRI
Capacity SEER EER Furnace
No. Air Handler Reference
13ACX-036-230 + TXV 35,600 14.50 12.00 CBX32MV-048 3469993
13ACX-036-230 + TXV 34,400 14.00 11.50 CBX40UHV-036 3469994
13ACX-036-230 + TXV 35,600 14.50 12.00 CBX40UHV-042 3469995
13ACX-036-230 + TXV 35,600 14.50 12.00 CBX40UHV-048 3469996
13ACX-036-230 + TXV 34,200 14.00 11.50 CH23-51 G60UHV-36B-090 3469997
13ACX-036-230 + TXV 34,000 13.00 11.00 CH23-51 G61MPV-36B-045 3469998
13ACX-036-230 + TXV 33,800 13.00 11.00 CH23-51 G61MPV-36B-070 3469999
13ACX-036-230 + TXV 34,000 13.50 11.00 CH23-51 G61MPV-36B-071 3470000
13ACX-036-230 + TXV 33,800 13.00 11.00 CH23-51 G71MPP-36B-070 3470001
13ACX-036-230 + TXV 34,200 13.50 11.50 CH33-36C G61MPV-36C-090 3470002
13ACX-036-230 + TXV 34,200 13.50 11.50 CH33-36C G71MPP-36C-090 3470003
13ACX-036-230 + TXV 35,400 14.00 12.00 CH33-43B G60UHV-36B-090 3470004
13ACX-036-230 + TXV 35,400 14.00 11.50 CH33-43B G61MPV-36B-045 3470005
13ACX-036-230 + TXV 35,400 14.00 11.50 CH33-43B G61MPV-36B-070 3470006
13ACX-036-230 + TXV 35,400 14.00 11.50 CH33-43B G61MPV-36B-071 3470007
13ACX-036-230 + TXV 35,400 14.00 11.50 CH33-43B G71MPP-36B-070 3470009
13ACX-036-230 + TXV 35,400 13.00 11.00 CH33-43B 3470011
13ACX-036-230 + TXV 34,800 14.00 12.00 CH33-43C G61MPV-36C-090 3470008
13ACX-036-230 + TXV 34,800 14.00 12.00 CH33-43C G71MPP-36C-090 3470010
13ACX-036-230 + TXV 34,800 13.50 11.50 CH33-44/48 G60UHV-36A-070 3470012
13ACX-036-230 + TXV 35,200 14.00 11.50 CH33-44/48 G60UHV-36B-090 3470013
13ACX-036-230 + TXV 34,600 13.50 11.00 CH33-44/48 G61MPV-36B-045 3470014
13ACX-036-230 + TXV 34,600 13.50 11.50 CH33-44/48 G61MPV-36B-070 3470015
13ACX-036-230 + TXV 34,400 13.50 11.00 CH33-44/48 G61MPV-36B-071 3470016
13ACX-036-230 + TXV 34,600 13.50 11.50 CH33-44/48 G71MPP-36B-070 3470017
13ACX-036-230 + TXV 34,600 13.00 11.00 CH33-44/48 3470018
13ACX-036-230 + TXV 35,400 14.00 11.50 CH33-48C G61MPV-60C-090 3470019
13ACX-036-230 + TXV 35,800 14.00 11.50 CH33-48C G61MPV-60C-091 3470020
13ACX-036-230 + TXV 35,600 14.00 11.50 CH33-48C G61MPV-60C-110 3470021
13ACX-036-230 + TXV 35,600 14.00 12.00 CH33-48C G61MPV-60C-111 3470022
13ACX-036-230 + TXV 35,400 14.00 11.50 CH33-48C G71MPP-36C-090 3470023
13ACX-036-230 + TXV 35,600 14.00 11.50 CH33-48C G71MPP-60C-110 3470024
13ACX-036-230 + TXV 34,600 13.00 11.00 CH33-48C 3470025
13ACX-036-230 + TXV 34,200 13.50 11.50 CR33-30/36 G61MPV-36C-090 3470026
13ACX-036-230 + TXV 34,200 13.50 11.50 CR33-30/36 G71MPP-36C-090 3470027
13ACX-036-230 + TXV 33,600 13.00 11.00 CR33-48 G61MPV-36B-045 3470028
13ACX-036-230 + TXV 33,600 13.50 11.00 CR33-48 G61MPV-36B-070 3470029
13ACX-036-230 + TXV 33,400 13.00 11.00 CR33-48 G61MPV-36B-071 3470030
13ACX-036-230 + TXV 34,000 13.50 11.00 CR33-48 G61MPV-60C-090 3470032
13ACX-036-230 + TXV 33,600 13.50 11.00 CR33-48 G71MPP-36B-070 3470031
13ACX-036-230 + TXV 34,000 13.50 11.00 CR33-48 G71MPP-60C-090 3470033
13ACX-036-230 + TXV 34,400 13.00 10.95 CR33-50/60 3470057
13ACX-036-230 + TXV 33,800 13.00 10.95 CX34-31 3470034
13ACX-036-230 + TXV 33,800 13.50 11.50 CX34-36 G61MPV-36C-090 3470035
13ACX-036-230 + TXV 33,800 13.50 11.50 CX34-36 G71MPP-36C-090 3470036
13ACX-036-230 + TXV 34,600 13.50 11.50 CX34-38 G60UHV-36A-070 3470037
13ACX-036-230 + TXV 35,400 14.00 11.50 CX34-38 G60UHV-36B-090 3470038
NOTES:
+ TXV = Matched with Thermostatic Expansion Valve.
+ RFC = Matched with RFC metering device.
Ratings are certified in accordance with USE certification program which is based on AHRI Standard 210/240; 95°F outdoor air temperature, 80°F db / 67°F wb entering
evaporator air with 25 ft. of connecting refrigerant lines.
All ratings include the use of a blower time delay relay (TDR). All Lennox variable-speed furnaces and Air Handlers have time delay capabilities. Other Furnaces and Air
Handlers may require an optional time delay relay (58M81) for field installation. See furnace or air handler specifications to determine if relay is needed.
*Most popular combination.
Also see Expansion Valve Kit Usage Table.

13ACX - 1.5 to 5 Ton Air Conditioner / Page 21


AHRI SYSTEM MATCHES
NOTE - For the latest up-to-date system matches please visit the AHRI web site at http://www.ahridirectory.org
Model Coil or AHRI
Capacity SEER EER Furnace
No. Air Handler Reference
13ACX-036-230 + TXV 34,600 13.50 11.50 CX34-38 G61MPV-36B-045 3470039
13ACX-036-230 + TXV 34,600 13.50 11.50 CX34-38 G61MPV-36B-070 3470040
13ACX-036-230 + TXV 34,200 14.00 11.50 CX34-38 G61MPV-36B-071 3470041
13ACX-036-230 + TXV 34,600 13.50 11.50 CX34-38 G71MPP-36B-070 3470042
13ACX-036-230 + TXV 34,600 13.00 11.00 CX34-38 3470043
13ACX-036-230 + TXV 35,600 14.50 12.00 CX34-43 G60UHV-36B-090 3470044
13ACX-036-230 + TXV 34,400 14.00 11.50 CX34-43 G61MPV-36B-045 3470045
13ACX-036-230 + TXV 34,800 14.00 11.50 CX34-43 G61MPV-36B-070 3470046
13ACX-036-230 + TXV 34,400 14.00 11.50 CX34-43 G61MPV-36B-071 3470047
13ACX-036-230 + TXV 35,000 14.00 12.00 CX34-43 G61MPV-36C-090 3470050
13ACX-036-230 + TXV 34,800 14.00 11.50 CX34-43 G71MPP-36B-070 3470048
13ACX-036-230 + TXV 35,000 14.00 12.00 CX34-43 G71MPP-36C-090 3470051
13ACX-036-230 + TXV 34,800 13.00 11.00 CX34-43 3470049
13ACX-036-230 + TXV 35,600 14.00 12.00 CX34-50/60C G60UHV-60C-110 3470052
13ACX-036-230 + TXV 35,400 14.00 11.50 CX34-50/60C G61MPV-60C-090 3470053
13ACX-036-230 + TXV 35,600 14.00 12.00 CX34-50/60C G61MPV-60C-111 3470054
13ACX-036-230 + TXV 35,000 14.00 11.50 CX34-50/60C G71MPP-36C-090 3470055
13ACX-036-230 + TXV 34,600 13.00 11.00 CX34-50/60C 3470056
13ACX-042-230 + RFC 42,000 13.50 11.00 C33-38 G60UHV-36B-090 3230519
13ACX-042-230 + RFC 41,500 13.00 11.00 C33-38 G61MPV-36B-070 3230520
13ACX-042-230 + RFC 41,500 13.00 11.00 C33-38 G71MPP-36B-070 3230559
13ACX-042-230 + RFC 42,000 13.50 11.60 C33-43 G60UHV-36B-090 3230521
13ACX-042-230 + RFC 42,000 14.00 11.60 C33-43 G60UHV-60C-090 3230523
13ACX-042-230 + RFC 42,000 14.00 11.60 C33-43 G60UHV-60C-110 3230524
13ACX-042-230 + RFC 42,000 13.00 11.00 C33-43 G61MPV-36B-070 3230522
13ACX-042-230 + RFC 42,500 13.50 11.60 C33-43 G61MPV-60C-090 3230525
13ACX-042-230 + RFC 42,000 14.00 11.60 C33-43 G61MPV-60C-110 3230526
13ACX-042-230 + RFC 42,000 13.00 11.00 C33-43 G71MPP-36B-070 3230560
13ACX-042-230 + RFC 42,000 14.00 11.60 C33-43 G71MPP-60C-110 3230564
13ACX-042-230 + RFC 41,500 13.00 10.90 C33-43 3230512
13ACX-042-230 + RFC 42,500 14.00 11.60 C33-49 G60UHV-60C-090 3230527
13ACX-042-230 + RFC 42,500 14.00 11.60 C33-49 G60UHV-60C-110 3230528
13ACX-042-230 + RFC 42,500 13.50 11.60 C33-49 G61MPV-60C-090 3230529
13ACX-042-230 + RFC 42,500 14.00 11.50 C33-49 G61MPV-60C-110 3230530
13ACX-042-230 + RFC 42,500 14.00 11.50 C33-49 G71MPP-60C-110 3230565
13ACX-042-230 + RFC 41,500 13.00 11.00 C33-49 3230513
13ACX-042-230 + RFC 42,000 14.00 11.60 C33-50/60C G60UHV-60C-090 3230531
13ACX-042-230 + RFC 42,000 14.00 11.60 C33-50/60C G60UHV-60C-110 3230532
13ACX-042-230 + RFC 42,000 13.50 11.00 C33-50/60C G61MPV-60C-090 3230533
13ACX-042-230 + RFC 42,000 13.50 11.60 C33-50/60C G61MPV-60C-110 3230534
13ACX-042-230 + RFC 42,000 13.50 11.60 C33-50/60C G71MPP-60C-110 3230566
13ACX-042-230 + RFC 41,500 13.00 10.80 C33-50/60C 3230514
13ACX-042-230 + RFC 42,500 13.50 11.60 CH33-43 G60UHV-36B-090 3230545
13ACX-042-230 + RFC 42,000 14.00 11.60 CH33-43 G60UHV-60C-090 3230549
13ACX-042-230 + RFC 42,500 13.50 11.60 CH33-43 G60UHV-60C-110 3230550
13ACX-042-230 + RFC 42,500 13.00 10.90 CH33-43 G61MPV-36B-045 3230546
13ACX-042-230 + RFC 42,500 13.00 11.00 CH33-43 G61MPV-36B-070 3230547
NOTES:
+ TXV = Matched with Thermostatic Expansion Valve.
+ RFC = Matched with RFC metering device.
Ratings are certified in accordance with USE certification program which is based on AHRI Standard 210/240; 95°F outdoor air temperature, 80°F db / 67°F wb entering
evaporator air with 25 ft. of connecting refrigerant lines.
All ratings include the use of a blower time delay relay (TDR). All Lennox variable-speed furnaces and Air Handlers have time delay capabilities. Other Furnaces and Air
Handlers may require an optional time delay relay (58M81) for field installation. See furnace or air handler specifications to determine if relay is needed.
*Most popular combination.
Also see Expansion Valve Kit Usage Table.

13ACX - 1.5 to 5 Ton Air Conditioner / Page 22


AHRI SYSTEM MATCHES
NOTE - For the latest up-to-date system matches please visit the AHRI web site at http://www.ahridirectory.org
Model Coil or AHRI
Capacity SEER EER Furnace
No. Air Handler Reference
13ACX-042-230 + RFC 42,500 13.00 11.00 CH33-43 G61MPV-36B-071 3230548
13ACX-042-230 + RFC 42,000 13.50 11.00 CH33-43 G61MPV-36C-090 3230551
13ACX-042-230 + RFC 42,000 13.50 11.60 CH33-43 G61MPV-60C-090 3230556
13ACX-042-230 + RFC 42,500 13.50 11.60 CH33-43 G61MPV-60C-110 3230557
13ACX-042-230 + RFC 42,500 13.00 11.00 CH33-43 G71MPP-36B-070 3230561
13ACX-042-230 + RFC 42,000 13.50 11.00 CH33-43 G71MPP-36C-090 3230562
13ACX-042-230 + RFC 42,500 13.50 11.60 CH33-43 G71MPP-60C-110 3230570
13ACX-042-230 + RFC 42,000 13.00 11.00 CH33-43 3230517
13ACX-042-230 + RFC 42,000 13.50 11.60 CH33-48 G60UHV-36B-090 3230535
13ACX-042-230 + RFC 42,000 13.50 11.00 CH33-48 G61MPV-60C-090 3230536
13ACX-042-230 + RFC 42,000 13.50 11.60 CH33-48 G61MPV-60C-110 3230537
13ACX-042-230 + RFC 42,000 13.50 11.60 CH33-48 G71MPP-60C-110 3230567
13ACX-042-230 + RFC 41,500 13.00 10.80 CH33-48 3230515
13ACX-042-230 + RFC 42,500 14.00 11.60 CH33-49 G60UHV-60C-090 3230552
13ACX-042-230 + RFC 43,000 14.00 11.60 CH33-49 G60UHV-60C-110 3230558
13ACX-042-230 + RFC 42,500 13.50 11.00 CH33-49 G61MPV-36C-090 3230553
13ACX-042-230 + RFC 42,500 13.50 11.60 CH33-49 G61MPV-60C-090 3230554
13ACX-042-230 + RFC 42,500 13.50 11.60 CH33-49 G61MPV-60C-110 3230555
13ACX-042-230 + RFC 42,500 13.50 11.00 CH33-49 G71MPP-36C-090 3230563
13ACX-042-230 + RFC 42,500 13.50 11.60 CH33-49 G71MPP-60C-110 3230569
13ACX-042-230 + RFC 42,000 13.00 11.00 CH33-49 3230518
13ACX-042-230 + RFC 42,000 14.00 11.60 CH33-50/60C G60DFV-60C-090 3230541
13ACX-042-230 + RFC 42,500 14.00 11.60 CH33-50/60C G60DFV-60C-110 3230542
13ACX-042-230 + RFC 43,000 14.00 11.60 CH33-50/60C G60UHV-60C-090 3230538
13ACX-042-230 + RFC 42,500 13.50 11.60 CH33-50/60C G61MPV-60C-090 3230539
13ACX-042-230 + RFC 42,500 13.50 11.60 CH33-50/60C G61MPV-60C-110 3230540
13ACX-042-230 + RFC 42,500 13.50 11.60 CH33-50/60C G71MPP-60C-110 3230568
13ACX-042-230 + RFC 42,000 13.00 11.00 CH33-50/60C 3230516
13ACX-042-230 + RFC 42,500 14.00 11.60 CR33-60 G60DFV-60D-135 3230543
13ACX-042-230 + RFC 42,000 14.00 11.60 CR33-60 G61MPV-60D-135 3230544
13ACX-042-230 + RFC 42,000 14.00 11.60 CR33-60 G71MPP-60D-135 3230571
13ACX-042-230 + TXV 40,500 13.50 11.00 C33-38 G60UHV-36B-090 3208609
13ACX-042-230 + TXV 40,500 13.00 11.00 C33-38 G61MPV-36B-070 3208574
13ACX-042-230 + TXV 40,500 13.00 11.00 C33-38 G61MPV-36B-071 3208578
13ACX-042-230 + TXV 40,000 13.00 10.80 C33-38 3208541
13ACX-042-230 + TXV 40,000 13.00 10.80 C33-38B 3293425
13ACX-042-230 + TXV 41,000 13.50 11.60 C33-43 G60UHV-36B-090 3208610
13ACX-042-230 + TXV 41,000 14.00 11.60 C33-43 G60UHV-60C-090 3208614
13ACX-042-230 + TXV 41,000 14.00 11.60 C33-43 G60UHV-60C-110 3208622
13ACX-042-230 + TXV 41,000 13.00 11.00 C33-43 G61MPV-36B-070 3208575
13ACX-042-230 + TXV 41,000 13.00 11.00 C33-43 G61MPV-36B-071 3208579
13ACX-042-230 + TXV 41,500 13.50 11.60 C33-43 G61MPV-60C-090 3208628
13ACX-042-230 + TXV 41,500 13.50 11.60 C33-43 G61MPV-60C-091 3208554
13ACX-042-230 + TXV 41,000 14.00 11.60 C33-43 G61MPV-60C-110 3208637
13ACX-042-230 + TXV 41,000 14.00 11.60 C33-43 G61MPV-60C-111 3208555
13ACX-042-230 + TXV 41,000 14.00 11.60 C33-43 G71MPP-60C-110 3208658
13ACX-042-230 + TXV 40,500 13.00 10.90 C33-43 3208542
NOTES:
+ TXV = Matched with Thermostatic Expansion Valve.
+ RFC = Matched with RFC metering device.
Ratings are certified in accordance with USE certification program which is based on AHRI Standard 210/240; 95°F outdoor air temperature, 80°F db / 67°F wb entering
evaporator air with 25 ft. of connecting refrigerant lines.
All ratings include the use of a blower time delay relay (TDR). All Lennox variable-speed furnaces and Air Handlers have time delay capabilities. Other Furnaces and Air
Handlers may require an optional time delay relay (58M81) for field installation. See furnace or air handler specifications to determine if relay is needed.
*Most popular combination.
Also see Expansion Valve Kit Usage Table.

13ACX - 1.5 to 5 Ton Air Conditioner / Page 23


AHRI SYSTEM MATCHES
NOTE - For the latest up-to-date system matches please visit the AHRI web site at http://www.ahridirectory.org
Model Coil or AHRI
Capacity SEER EER Furnace
No. Air Handler Reference
13ACX-042-230 + TXV 41,000 14.00 11.60 C33-49 G60UHV-60C-090 3208615
13ACX-042-230 + TXV 41,000 14.00 11.60 C33-49 G60UHV-60C-110 3208623
13ACX-042-230 + TXV 41,000 13.50 11.60 C33-49 G61MPV-60C-090 3208629
13ACX-042-230 + TXV 41,000 13.50 11.60 C33-49 G61MPV-60C-091 3208556
13ACX-042-230 + TXV 41,000 14.00 11.60 C33-49 G61MPV-60C-110 3208638
13ACX-042-230 + TXV 41,000 14.00 11.60 C33-49 G61MPV-60C-111 3208557
13ACX-042-230 + TXV 41,000 14.00 11.60 C33-49 G71MPP-60C-110 3208659
13ACX-042-230 + TXV 41,000 13.00 11.00 C33-49 3208543
13ACX-042-230 + TXV 40,500 14.00 11.60 C33-50/60C G60UHV-60C-090 3208616
13ACX-042-230 + TXV 41,000 14.00 11.60 C33-50/60C G60UHV-60C-110 3208624
13ACX-042-230 + TXV 41,000 13.50 11.00 C33-50/60C G61MPV-60C-090 3208630
13ACX-042-230 + TXV 41,000 13.50 11.00 C33-50/60C G61MPV-60C-091 3208558
13ACX-042-230 + TXV 41,000 14.00 11.60 C33-50/60C G61MPV-60C-110 3208639
13ACX-042-230 + TXV 41,000 14.00 11.60 C33-50/60C G61MPV-60C-111 3208559
13ACX-042-230 + TXV 41,000 14.00 11.60 C33-50/60C G71MPP-60C-110 3208660
13ACX-042-230 + TXV 40,000 13.00 10.80 C33-50/60C 3208544
13ACX-042-230 + TXV 40,000 13.00 11.00 CB26UH-042-R+39L72 3208599
13ACX-042-230 + TXV 41,500 14.00 11.50 CB27UH-042-230 3208649
13ACX-042-230 + TXV 41,500 14.00 11.50 CB27UH-048-230 3208650
13ACX-042-230 + TXV 39,500 13.00 10.90 CB30M-41P 3208600
13ACX-042-230 + TXV 39,500 13.00 10.90 CB30M-46P 3208601
13ACX-042-230 + TXV 41,000 13.00 11.00 CB30M-51P 3208602
13ACX-042-230 + TXV 40,000 13.00 11.00 CBX26UH-042 3208605
13ACX-042-230 + TXV 41,500 14.00 11.50 CBX27UH-042-230 3208651
13ACX-042-230 + TXV 41,500 14.00 11.50 CBX27UH-048-230 3208652
13ACX-042-230 + TXV 39,500 13.00 10.90 CBX32M-036 3208643
13ACX-042-230 + TXV 39,500 13.00 10.90 CBX32M-042 3208644
13ACX-042-230 + TXV 41,000 13.00 11.00 CBX32M-048 3208645
13ACX-042-230 + TXV 41,500 14.00 11.60 CBX32MV-048-230 3208606
13ACX-042-230 + TXV 41,500 14.00 11.50 CBX40UHV-042 3291694
13ACX-042-230 + TXV 41,500 14.00 11.60 CBX40UHV-048 3291728
13ACX-042-230 + TXV 40,500 13.50 11.00 CH23-65 G60UHV-60C-090 3208617
13ACX-042-230 + TXV 40,500 13.50 11.00 CH23-65 G61MPV-60C-090 3208631
13ACX-042-230 + TXV 40,500 13.50 11.00 CH23-65 G61MPV-60C-091 3208560
13ACX-042-230 + TXV 39,500 13.00 10.70 CH23-65 3208545
13ACX-042-230 + TXV 41,500 13.50 11.60 CH33-43 G60UHV-36B-090 3208581
13ACX-042-230 + TXV 41,000 14.00 11.60 CH33-43 G60UHV-60C-090 3208585
13ACX-042-230 + TXV 41,000 14.00 11.60 CH33-43 G60UHV-60C-110 3208586
13ACX-042-230 + TXV 41,500 13.00 10.90 CH33-43 G61MPV-36B-045 3208582
13ACX-042-230 + TXV 41,500 13.00 11.00 CH33-43 G61MPV-36B-070 3208583
13ACX-042-230 + TXV 41,500 13.00 11.00 CH33-43 G61MPV-36B-071 3208584
13ACX-042-230 + TXV 41,000 13.50 11.00 CH33-43 G61MPV-36C-090 3208587
13ACX-042-230 + TXV 41,000 13.50 11.60 CH33-43 G61MPV-60C-090 3208588
13ACX-042-230 + TXV 41,500 13.50 11.00 CH33-43 G61MPV-60C-091 3208595
13ACX-042-230 + TXV 41,000 14.00 11.60 CH33-43 G61MPV-60C-110 3208589
13ACX-042-230 + TXV 41,000 13.50 11.00 CH33-43 G61MPV-60C-111 3208596
13ACX-042-230 + TXV 41,500 13.00 11.00 CH33-43 G71MPP-36B-070 3208653
NOTES:
+ TXV = Matched with Thermostatic Expansion Valve.
+ RFC = Matched with RFC metering device.
Ratings are certified in accordance with USE certification program which is based on AHRI Standard 210/240; 95°F outdoor air temperature, 80°F db / 67°F wb entering
evaporator air with 25 ft. of connecting refrigerant lines.
All ratings include the use of a blower time delay relay (TDR). All Lennox variable-speed furnaces and Air Handlers have time delay capabilities. Other Furnaces and Air
Handlers may require an optional time delay relay (58M81) for field installation. See furnace or air handler specifications to determine if relay is needed.
*Most popular combination.
Also see Expansion Valve Kit Usage Table.

13ACX - 1.5 to 5 Ton Air Conditioner / Page 24


AHRI SYSTEM MATCHES
NOTE - For the latest up-to-date system matches please visit the AHRI web site at http://www.ahridirectory.org
Model Coil or AHRI
Capacity SEER EER Furnace
No. Air Handler Reference
13ACX-042-230 + TXV 41,000 13.50 11.00 CH33-43 G71MPP-36C-090 3208654
13ACX-042-230 + TXV 41,000 14.00 11.60 CH33-43 G71MPP-60C-110 3208656
13ACX-042-230 + TXV 41,000 13.00 11.00 CH33-43 3208539
13ACX-042-230 + TXV 41,000 13.50 11.60 CH33-48 G60UHV-36B-090 3208611
13ACX-042-230 + TXV 41,000 13.50 11.00 CH33-48 G61MPV-60C-090 3208632
13ACX-042-230 + TXV 41,000 13.50 11.00 CH33-48 G61MPV-60C-091 3208561
13ACX-042-230 + TXV 41,000 13.50 11.60 CH33-48 G61MPV-60C-110 3208640
13ACX-042-230 + TXV 41,000 13.50 11.60 CH33-48 G61MPV-60C-111 3208562
13ACX-042-230 + TXV 41,000 13.50 11.60 CH33-48 G71MPP-60C-110 3208661
13ACX-042-230 + TXV 40,000 13.00 10.80 CH33-48 3208546
13ACX-042-230 + TXV 41,500 14.00 11.60 CH33-49 G60UHV-60C-090 3208590
13ACX-042-230 + TXV 41,500 14.00 11.60 CH33-49 G60UHV-60C-110 3208591
13ACX-042-230 + TXV 41,500 13.50 11.00 CH33-49 G61MPV-36C-090 3208592
13ACX-042-230 + TXV 41,500 13.50 11.60 CH33-49 G61MPV-60C-090 3208593
13ACX-042-230 + TXV 41,500 13.50 11.00 CH33-49 G61MPV-60C-091 3208597
13ACX-042-230 + TXV 41,500 14.00 11.60 CH33-49 G61MPV-60C-110 3208594
13ACX-042-230 + TXV 41,500 14.00 11.60 CH33-49 G61MPV-60C-111 3208598
13ACX-042-230 + TXV 41,500 13.50 11.00 CH33-49 G71MPP-36C-090 3208655
13ACX-042-230 + TXV 41,500 14.00 11.60 CH33-49 G71MPP-60C-110 3208657
13ACX-042-230 + TXV 41,000 13.00 11.00 CH33-49 3208540
13ACX-042-230 + TXV 41,500 14.00 11.60 CH33-50/60C G60UHV-60C-090 3208618
13ACX-042-230 + TXV 41,500 13.50 11.60 CH33-50/60C G61MPV-60C-090 3208633
13ACX-042-230 + TXV 41,500 13.50 11.00 CH33-50/60C G61MPV-60C-091 3208563
13ACX-042-230 + TXV 41,500 13.50 11.60 CH33-50/60C G61MPV-60C-110 3208641
13ACX-042-230 + TXV 41,500 13.50 11.60 CH33-50/60C G61MPV-60C-111 3208564
13ACX-042-230 + TXV 41,500 13.50 11.60 CH33-50/60C G71MPP-60C-110 3208662
13ACX-042-230 + TXV 41,000 13.00 11.00 CH33-50/60C 3208547
13ACX-042-230 + TXV 40,000 13.00 10.80 CR33-50/60 G60DFV-60C-090 3208607
13ACX-042-230 + TXV 41,000 14.00 11.60 CR33-50/60 G60DFV-60C-110 3208608
13ACX-042-230 + TXV 41,000 13.50 11.00 CR33-50/60 G61MPV-60C-091 3208565
13ACX-042-230 + TXV 40,500 14.00 11.00 CR33-50/60 G61MPV-60C-111 3208566
13ACX-042-230 + TXV 40,000 13.00 10.80 CR33-50/60 3208548
13ACX-042-230 + TXV 41,000 14.00 11.60 CR33-60 G60DFV-60D-135 3208646
13ACX-042-230 + TXV 41,000 14.00 11.60 CR33-60 G61MPV-60D-135 3208642
13ACX-042-230 + TXV 41,000 14.00 11.60 CR33-60 G71MPP-60D-135 3208665
13ACX-042-230 + TXV 40,000 13.00 10.80 CR33-60 3208549
13ACX-042-230 + TXV 40,500 13.50 11.00 CX34-38 G60UHV-36B-090 3208612
13ACX-042-230 + TXV 40,500 13.00 11.00 CX34-38 G61MPV-36B-070 3208573
13ACX-042-230 + TXV 40,500 13.00 11.00 CX34-38 G61MPV-36B-071 3208577
13ACX-042-230 + TXV 40,000 13.00 10.80 CX34-38B 3293406
13ACX-042-230 + TXV 41,000 13.50 11.60 CX34-43 G60UHV-36B-090 3208613
13ACX-042-230 + TXV 41,000 14.00 11.60 CX34-43 G60UHV-60C-090 3208619
13ACX-042-230 + TXV 41,000 14.00 11.60 CX34-43 G60UHV-60C-110 3208625
13ACX-042-230 + TXV 41,000 13.00 11.00 CX34-43 G61MPV-36B-070 3208576
13ACX-042-230 + TXV 41,000 13.00 11.00 CX34-43 G61MPV-36B-071 3208580
13ACX-042-230 + TXV 41,500 13.50 11.60 CX34-43 G61MPV-60C-090 3208634
13ACX-042-230 + TXV 41,500 13.50 11.60 CX34-43 G61MPV-60C-091 3208567
NOTES:
+ TXV = Matched with Thermostatic Expansion Valve.
+ RFC = Matched with RFC metering device.
Ratings are certified in accordance with USE certification program which is based on AHRI Standard 210/240; 95°F outdoor air temperature, 80°F db / 67°F wb entering
evaporator air with 25 ft. of connecting refrigerant lines.
All ratings include the use of a blower time delay relay (TDR). All Lennox variable-speed furnaces and Air Handlers have time delay capabilities. Other Furnaces and Air
Handlers may require an optional time delay relay (58M81) for field installation. See furnace or air handler specifications to determine if relay is needed.
*Most popular combination.
Also see Expansion Valve Kit Usage Table.

13ACX - 1.5 to 5 Ton Air Conditioner / Page 25


AHRI SYSTEM MATCHES
NOTE - For the latest up-to-date system matches please visit the AHRI web site at http://www.ahridirectory.org
Model Coil or AHRI
Capacity SEER EER Furnace
No. Air Handler Reference
13ACX-042-230 + TXV 41,000 14.00 11.60 CX34-43 G61MPV-60C-110 3208647
13ACX-042-230 + TXV 41,000 14.00 11.60 CX34-43 G61MPV-60C-111 3208568
13ACX-042-230 + TXV 41,000 14.00 11.60 CX34-43 G71MPP-60C-110 3208663
13ACX-042-230 + TXV 40,500 13.00 10.90 CX34-43 3208551
13ACX-042-230 + TXV 41,000 14.00 11.60 CX34-49 G60UHV-60C-090 3208620
13ACX-042-230 + TXV 41,000 14.00 11.60 CX34-49 G60UHV-60C-110 3208626
13ACX-042-230 + TXV 41,000 13.50 11.60 CX34-49 G61MPV-60C-090 3208635
13ACX-042-230 + TXV 41,000 13.50 11.60 CX34-49 G61MPV-60C-091 3208569
13ACX-042-230 + TXV 41,000 14.00 11.60 CX34-49 G61MPV-60C-110 3208648
13ACX-042-230 + TXV 41,000 14.00 11.60 CX34-49 G61MPV-60C-111 3208570
13ACX-042-230 + TXV 41,000 14.00 11.60 CX34-49 G71MPP-60C-110 3208664
13ACX-042-230 + TXV 41,000 13.00 11.00 CX34-49 3208552
13ACX-042-230 + TXV 40,500 14.00 11.60 CX34-50/60C G60UHV-60C-090 3208621
13ACX-042-230 + TXV 41,000 14.00 11.60 CX34-50/60C G60UHV-60C-110 3208627
13ACX-042-230 + TXV 41,000 13.50 11.00 CX34-50/60C G61MPV-60C-090 3208636
13ACX-042-230 + TXV 41,000 13.50 11.00 CX34-50/60C G61MPV-60C-091 3208571
13ACX-042-230 + TXV 41,000 14.00 11.60 CX34-50/60C G61MPV-60C-111 3208572
13ACX-042-230 + TXV 40,000 13.00 10.80 CX34-50/60C 3208553
13ACX-048-230 + RFC 47,500 13.50 11.60 C33-38 G60UHV-60C-090 3230589
13ACX-048-230 + RFC 47,000 13.50 11.00 C33-38 G60UHV-60C-110 3230590
13ACX-048-230 + RFC 47,000 13.50 11.00 C33-38 G61MPV-60C-090 3230591
13ACX-048-230 + RFC 47,000 13.50 11.00 C33-38 G61MPV-60C-110 3230592
13ACX-048-230 + RFC 47,000 13.50 11.00 C33-38 G71MPP-60C-110 3230645
13ACX-048-230 + RFC 47,000 13.00 11.00 C33-38 3230573
13ACX-048-230 + RFC 48,000 14.00 11.60 C33-43 G60UHV-60C-090 3230593
13ACX-048-230 + RFC 47,500 14.00 11.60 C33-43 G60UHV-60C-110 3230594
13ACX-048-230 + RFC 47,500 13.50 11.00 C33-43 G61MPV-60C-090 3230595
13ACX-048-230 + RFC 47,500 13.50 11.00 C33-43 G61MPV-60C-110 3230596
13ACX-048-230 + RFC 47,500 13.50 11.00 C33-43 G71MPP-60C-110 3230646
13ACX-048-230 + RFC 47,500 13.00 11.00 C33-43 3230574
13ACX-048-230 + RFC 49,000 14.00 11.60 C33-49 G60UHV-60C-090 3230597
13ACX-048-230 + RFC 48,500 14.00 11.60 C33-49 G60UHV-60C-110 3230598
13ACX-048-230 + RFC 48,500 14.00 11.60 C33-49 G61MPV-60C-090 3230599
13ACX-048-230 + RFC 48,500 14.00 11.60 C33-49 G61MPV-60C-110 3230600
13ACX-048-230 + RFC 48,500 14.00 11.60 C33-49 G71MPP-60C-110 3230647
13ACX-048-230 + RFC 48,000 13.50 11.00 C33-49 3230575
13ACX-048-230 + RFC 47,500 13.50 11.60 C33-50/60C G60UHV-60C-090 3230601
13ACX-048-230 + RFC 47,500 13.50 11.60 C33-50/60C G60UHV-60C-110 3230602
13ACX-048-230 + RFC 47,000 13.50 11.00 C33-50/60C G61MPV-60C-090 3230603
13ACX-048-230 + RFC 47,000 13.50 11.00 C33-50/60C G61MPV-60C-110 3230604
13ACX-048-230 + RFC 47,000 13.50 11.00 C33-50/60C G71MPP-60C-110 3230648
13ACX-048-230 + RFC 47,000 13.00 11.00 C33-50/60C 3230572
13ACX-048-230 + RFC 48,500 14.00 12.00 C33-60D G60UHV-60D-135 3230609
13ACX-048-230 + RFC 48,500 14.00 11.60 C33-60D G61MPV-60D-135 3230610
13ACX-048-230 + RFC 48,500 14.00 11.60 C33-60D G71MPP-60D-135 3230656
13ACX-048-230 + RFC 48,000 13.50 11.00 C33-60D 3230576
13ACX-048-230 + RFC 49,500 14.00 11.60 C33-62C G60UHV-60C-090 3230605
NOTES:
+ TXV = Matched with Thermostatic Expansion Valve.
+ RFC = Matched with RFC metering device.
Ratings are certified in accordance with USE certification program which is based on AHRI Standard 210/240; 95°F outdoor air temperature, 80°F db / 67°F wb entering
evaporator air with 25 ft. of connecting refrigerant lines.
All ratings include the use of a blower time delay relay (TDR). All Lennox variable-speed furnaces and Air Handlers have time delay capabilities. Other Furnaces and Air
Handlers may require an optional time delay relay (58M81) for field installation. See furnace or air handler specifications to determine if relay is needed.
*Most popular combination.
Also see Expansion Valve Kit Usage Table.

13ACX - 1.5 to 5 Ton Air Conditioner / Page 26


AHRI SYSTEM MATCHES
NOTE - For the latest up-to-date system matches please visit the AHRI web site at http://www.ahridirectory.org
Model Coil or AHRI
Capacity SEER EER Furnace
No. Air Handler Reference
13ACX-048-230 + RFC 49,500 14.00 12.00 C33-62C G60UHV-60C-110 3230606
13ACX-048-230 + RFC 49,000 14.00 11.60 C33-62C G61MPV-60C-090 3230607
13ACX-048-230 + RFC 49,500 14.00 11.60 C33-62C G61MPV-60C-110 3230608
13ACX-048-230 + RFC 49,500 14.00 11.60 C33-62C G71MPP-60C-110 3230649
13ACX-048-230 + RFC 49,000 13.50 11.60 C33-62C 3230577
13ACX-048-230 + RFC 49,000 14.00 12.00 C33-62D G60UHV-60D-135 3230611
13ACX-048-230 + RFC 49,000 14.00 12.00 C33-62D G61MPV-60D-135 3230612
13ACX-048-230 + RFC 48,500 13.50 11.00 C33-62D 3230578
13ACX-048-230 + RFC 48,000 14.00 11.60 CH23-68 G60UHV-60D-135 3230613
13ACX-048-230 + RFC 48,000 14.00 11.60 CH23-68 G61MPV-60D-135 3230614
13ACX-048-230 + RFC 48,000 14.00 11.60 CH23-68 G71MPP-60D-135 3230657
13ACX-048-230 + RFC 47,500 13.50 11.00 CH23-68 3230579
13ACX-048-230 + RFC 48,000 14.00 11.60 CH33-43 G60UHV-60C-090 3230633
13ACX-048-230 + RFC 48,000 13.50 11.60 CH33-43 G60UHV-60C-110 3230634
13ACX-048-230 + RFC 47,500 13.50 11.00 CH33-43 G61MPV-60C-090 3230635
13ACX-048-230 + RFC 47,500 13.50 11.00 CH33-43 G61MPV-60C-110 3230636
13ACX-048-230 + RFC 47,500 13.50 11.00 CH33-43 G71MPP-60C-110 3230653
13ACX-048-230 + RFC 47,500 13.00 11.00 CH33-43 3230586
13ACX-048-230 + RFC 47,500 13.50 11.00 CH33-48 G60UHV-60C-090 3230615
13ACX-048-230 + RFC 47,500 13.50 11.60 CH33-48 G60UHV-60C-110 3230616
13ACX-048-230 + RFC 47,500 13.50 11.00 CH33-48 G61MPV-60C-090 3230617
13ACX-048-230 + RFC 47,500 13.50 11.00 CH33-48 G61MPV-60C-110 3230618
13ACX-048-230 + RFC 47,500 13.50 11.00 CH33-48 G71MPP-60C-110 3230650
13ACX-048-230 + RFC 47,000 13.00 11.00 CH33-48 3230580
13ACX-048-230 + RFC 48,500 14.00 11.60 CH33-49 G60UHV-60C-090 3230637
13ACX-048-230 + RFC 48,500 14.00 11.60 CH33-49 G60UHV-60C-110 3230638
13ACX-048-230 + RFC 48,500 14.00 11.60 CH33-49 G61MPV-60C-090 3230639
13ACX-048-230 + RFC 48,500 14.00 11.60 CH33-49 G61MPV-60C-110 3230640
13ACX-048-230 + RFC 48,500 14.00 11.60 CH33-49 G71MPP-60C-110 3230654
13ACX-048-230 + RFC 48,000 13.50 11.00 CH33-49 3230587
13ACX-048-230 + RFC 48,500 14.00 11.60 CH33-50/60C G60UHV-60C-090 3230619
13ACX-048-230 + RFC 48,000 14.00 11.60 CH33-50/60C G60UHV-60C-110 3230620
13ACX-048-230 + RFC 48,000 13.50 11.00 CH33-50/60C G61MPV-60C-090 3230621
13ACX-048-230 + RFC 48,000 13.50 11.00 CH33-50/60C G61MPV-60C-110 3230622
13ACX-048-230 + RFC 48,000 13.50 11.00 CH33-50/60C G71MPP-60C-110 3230651
13ACX-048-230 + RFC 48,000 13.50 11.00 CH33-50/60C 3230581
13ACX-048-230 + RFC 48,000 14.00 11.60 CH33-60D G60UHV-60D-135 3230623
13ACX-048-230 + RFC 48,000 14.00 11.60 CH33-60D G61MPV-60D-135 3230624
13ACX-048-230 + RFC 48,000 14.00 11.60 CH33-60D G71MPP-60D-135 3230658
13ACX-048-230 + RFC 47,500 13.00 11.00 CH33-60D 3230582
13ACX-048-230 + RFC 48,500 14.00 11.60 CH33-62D G60UHV-60C-090 3230641
13ACX-048-230 + RFC 48,000 14.00 11.60 CH33-62D G60UHV-60C-110 3230642
13ACX-048-230 + RFC 48,000 14.00 11.60 CH33-62D G61MPV-60C-090 3230643
13ACX-048-230 + RFC 48,000 14.00 11.60 CH33-62D G61MPV-60C-110 3230644
13ACX-048-230 + RFC 48,000 14.00 11.60 CH33-62D G71MPP-60C-110 3230655
13ACX-048-230 + RFC 47,500 13.50 11.00 CH33-62D 3230588
13ACX-048-230 + RFC 48,500 14.00 12.00 CH33-62D G60UHV-60D-135 3230625
NOTES:
+ TXV = Matched with Thermostatic Expansion Valve.
+ RFC = Matched with RFC metering device.
Ratings are certified in accordance with USE certification program which is based on AHRI Standard 210/240; 95°F outdoor air temperature, 80°F db / 67°F wb entering
evaporator air with 25 ft. of connecting refrigerant lines.
All ratings include the use of a blower time delay relay (TDR). All Lennox variable-speed furnaces and Air Handlers have time delay capabilities. Other Furnaces and Air
Handlers may require an optional time delay relay (58M81) for field installation. See furnace or air handler specifications to determine if relay is needed.
*Most popular combination.
Also see Expansion Valve Kit Usage Table.

13ACX - 1.5 to 5 Ton Air Conditioner / Page 27


AHRI SYSTEM MATCHES
NOTE - For the latest up-to-date system matches please visit the AHRI web site at http://www.ahridirectory.org
Model Coil or AHRI
Capacity SEER EER Furnace
No. Air Handler Reference
13ACX-048-230 + RFC 48,500 14.00 11.60 CH33-62D G61MPV-60D-135 3230626
13ACX-048-230 + RFC 48,500 14.00 11.60 CH33-62D G71MPP-60D-135 3230659
13ACX-048-230 + RFC 48,000 13.00 11.00 CH33-62D 3230583
13ACX-048-230 + RFC 47,000 13.50 11.00 CR33-50/60 G60DFV-60C-090 3230627
13ACX-048-230 + RFC 46,500 13.50 11.00 CR33-50/60 G60DFV-60C-110 3230628
13ACX-048-230 + RFC 46,500 13.50 11.00 CR33-50/60 G61MPV-60C-090 3230629
13ACX-048-230 + RFC 46,500 13.50 11.00 CR33-50/60 G61MPV-60C-110 3230630
13ACX-048-230 + RFC 46,500 13.50 11.00 CR33-50/60 G71MPP-60C-110 3230652
13ACX-048-230 + RFC 46,000 13.00 10.50 CR33-50/60 3230584
13ACX-048-230 + RFC 47,000 13.50 11.60 CR33-60 G60DFV-60D-135 3230631
13ACX-048-230 + RFC 46,500 13.50 11.00 CR33-60 G61MPV-60D-135 3230632
13ACX-048-230 + RFC 46,500 13.50 11.00 CR33-60 G71MPP-60D-135 3230660
13ACX-048-230 + RFC 46,000 13.00 10.50 CR33-60 3230585
13ACX-048-230 + TXV 47,500 13.50 11.60 C33-38 G60UHV-60C-090 3229366
13ACX-048-230 + TXV 47,000 13.50 11.00 C33-38 G60UHV-60C-110 3229378
13ACX-048-230 + TXV 47,000 13.50 11.00 C33-38 G61MPV-60C-090 3229397
13ACX-048-230 + TXV 47,000 13.50 11.00 C33-38 G61MPV-60C-110 3229410
13ACX-048-230 + TXV 47,000 13.50 11.00 C33-38 G71MPP-60C-110 3229436
13ACX-048-230 + TXV 47,000 13.00 11.00 C33-38 3229305
13ACX-048-230 + TXV 48,000 14.00 11.60 C33-43 G60UHV-60C-090 3229367
13ACX-048-230 + TXV 47,500 14.00 11.60 C33-43 G60UHV-60C-110 3229379
13ACX-048-230 + TXV 47,500 13.50 11.60 C33-43 G61MPV-60C-090 3229398
13ACX-048-230 + TXV 47,500 13.50 11.00 C33-43 G61MPV-60C-091 3229312
13ACX-048-230 + TXV 47,500 13.50 11.60 C33-43 G61MPV-60C-110 3229411
13ACX-048-230 + TXV 47,500 13.50 11.00 C33-43 G61MPV-60C-111 3229313
13ACX-048-230 + TXV 47,500 13.50 11.60 C33-43 G71MPP-60C-110 3229437
13ACX-048-230 + TXV 47,500 13.00 11.00 C33-43 3229306
13ACX-048-230 + TXV 49,000 14.00 11.60 C33-49 G60UHV-60C-090 3229368
13ACX-048-230 + TXV 48,500 14.00 11.60 C33-49 G60UHV-60C-110 3229380
13ACX-048-230 + TXV 48,500 14.00 11.60 C33-49 G61MPV-60C-090 3229399
13ACX-048-230 + TXV 48,500 13.50 11.60 C33-49 G61MPV-60C-091 3229314
13ACX-048-230 + TXV 48,500 14.00 11.60 C33-49 G61MPV-60C-110 3229412
13ACX-048-230 + TXV 48,500 14.00 11.60 C33-49 G61MPV-60C-111 3229315
13ACX-048-230 + TXV 48,500 14.00 11.60 C33-49 G71MPP-60C-110 3229438
13ACX-048-230 + TXV 48,000 13.50 11.00 C33-49 3229307
13ACX-048-230 + TXV 47,500 13.50 11.60 C33-50/60C G60UHV-60C-090 3229369
13ACX-048-230 + TXV 47,500 13.50 11.60 C33-50/60C G60UHV-60C-110 3229381
13ACX-048-230 + TXV 47,000 13.50 11.00 C33-50/60C G61MPV-60C-090 3229400
13ACX-048-230 + TXV 47,000 13.50 11.00 C33-50/60C G61MPV-60C-091 3229316
13ACX-048-230 + TXV 47,000 13.50 11.00 C33-50/60C G61MPV-60C-110 3229413
13ACX-048-230 + TXV 47,000 13.50 11.00 C33-50/60C G61MPV-60C-111 3229317
13ACX-048-230 + TXV 47,000 13.50 11.00 C33-50/60C G71MPP-60C-110 3229439
13ACX-048-230 + TXV 47,000 13.00 11.00 C33-50/60C 3229308
13ACX-048-230 + TXV 48,500 14.00 12.00 C33-60D G60UHV-60D-135 3229390
13ACX-048-230 + TXV 48,500 14.00 11.60 C33-60D G61MPV-60D-135 3229418
13ACX-048-230 + TXV 48,500 14.00 11.60 C33-60D G71MPP-60D-135 3229444
13ACX-048-230 + TXV 48,000 13.50 11.00 C33-60D 3229309
NOTES:
+ TXV = Matched with Thermostatic Expansion Valve.
+ RFC = Matched with RFC metering device.
Ratings are certified in accordance with USE certification program which is based on AHRI Standard 210/240; 95°F outdoor air temperature, 80°F db / 67°F wb entering
evaporator air with 25 ft. of connecting refrigerant lines.
All ratings include the use of a blower time delay relay (TDR). All Lennox variable-speed furnaces and Air Handlers have time delay capabilities. Other Furnaces and Air
Handlers may require an optional time delay relay (58M81) for field installation. See furnace or air handler specifications to determine if relay is needed.
*Most popular combination.
Also see Expansion Valve Kit Usage Table.

13ACX - 1.5 to 5 Ton Air Conditioner / Page 28


AHRI SYSTEM MATCHES
NOTE - For the latest up-to-date system matches please visit the AHRI web site at http://www.ahridirectory.org
Model Coil or AHRI
Capacity SEER EER Furnace
No. Air Handler Reference
13ACX-048-230 + TXV 49,500 14.00 11.60 C33-62C G60UHV-60C-090 3229370
13ACX-048-230 + TXV 49,500 14.00 12.00 C33-62C G60UHV-60C-110 3229382
13ACX-048-230 + TXV 49,000 14.00 11.60 C33-62C G61MPV-60C-090 3229401
13ACX-048-230 + TXV 49,000 14.00 11.60 C33-62C G61MPV-60C-091 3229318
13ACX-048-230 + TXV 49,500 14.00 11.60 C33-62C G61MPV-60C-110 3229414
13ACX-048-230 + TXV 49,500 14.00 11.60 C33-62C G61MPV-60C-111 3229319
13ACX-048-230 + TXV 49,500 14.00 11.60 C33-62C G71MPP-60C-110 3229440
13ACX-048-230 + TXV 49,000 13.50 11.60 C33-62C 3229310
13ACX-048-230 + TXV 49,000 14.00 12.00 C33-62D G60UHV-60D-135 3229391
13ACX-048-230 + TXV 49,000 14.00 12.00 C33-62D G61MPV-60D-135 3229419
13ACX-048-230 + TXV 49,000 14.00 12.00 C33-62D G71MPP-60D-135 3229445
13ACX-048-230 + TXV 48,500 13.50 11.00 C33-62D 3229311
13ACX-048-230 + TXV 48,500 14.00 11.60 CB26UH-048-R+39L72 3229352
13ACX-048-230 + TXV 47,500 14.00 11.50 CB27UH-048-230 3229429
13ACX-048-230 + TXV 47,500 14.00 11.50 CB27UH-060-230 3229430
13ACX-048-230 + TXV 49,500 14.00 11.60 CB30M-46P 3229353
13ACX-048-230 + TXV 47,500 13.50 11.00 CB30M-51P 3229354
13ACX-048-230 + TXV 48,500 13.50 11.60 CB30M-65P 3229355
13ACX-048-230 + TXV 48,500 14.00 11.60 CBX26UH-048 3229360
13ACX-048-230 + TXV 47,500 14.00 11.50 CBX27UH-048-230 3229431
13ACX-048-230 + TXV 47,500 14.00 11.50 CBX27UH-060-230 3229432
13ACX-048-230 + TXV 49,500 14.00 11.60 CBX32M-042 3229426
13ACX-048-230 + TXV 47,500 13.50 11.00 CBX32M-048 3229427
13ACX-048-230 + TXV 48,500 13.50 11.60 CBX32M-060 3229428
13ACX-048-230 + TXV 48,000 13.50 11.60 CBX32MV-048-230 3229361
13ACX-048-230 + TXV 48,500 14.00 11.60 CBX32MV-060-230 3229362
13ACX-048-230 + TXV 48,000 13.50 11.60 CBX40UHV-048 3291730
13ACX-048-230 + TXV 48,500 14.00 11.60 CBX40UHV-060 3291808
13ACX-048-230 + TXV 48,000 14.00 11.60 CH23-68 G60UHV-60D-135 3229392
13ACX-048-230 + TXV 48,000 14.00 11.60 CH23-68 G61MPV-60D-135 3229420
13ACX-048-230 + TXV 48,000 14.00 11.60 CH23-68 G71MPP-60D-135 3229446
13ACX-048-230 + TXV 47,500 13.50 11.00 CH23-68 3229288
13ACX-048-230 + TXV 48,000 14.00 11.60 CH33-43 G60UHV-60C-090 3229334
13ACX-048-230 + TXV 48,000 13.50 11.60 CH33-43 G60UHV-60C-110 3229344
13ACX-048-230 + TXV 47,500 13.50 11.00 CH33-43 G61MPV-60C-090 3229345
13ACX-048-230 + TXV 47,500 13.50 11.00 CH33-43 G61MPV-60C-091 3229346
13ACX-048-230 + TXV 47,500 13.50 11.00 CH33-43 G61MPV-60C-110 3229335
13ACX-048-230 + TXV 47,500 13.50 11.00 CH33-43 G61MPV-60C-111 3229347
13ACX-048-230 + TXV 47,500 13.50 11.00 CH33-43 G71MPP-60C-110 3229433
13ACX-048-230 + TXV 47,500 13.00 11.00 CH33-43 3229302
13ACX-048-230 + TXV 47,000 13.00 11.00 CH33-44/48 3229289
13ACX-048-230 + TXV 47,500 13.50 11.60 CH33-48 G60UHV-60C-090 3229371
13ACX-048-230 + TXV 47,500 13.50 11.60 CH33-48 G60UHV-60C-110 3229383
13ACX-048-230 + TXV 47,500 13.50 11.00 CH33-48 G61MPV-60C-090 3229402
13ACX-048-230 + TXV 47,500 13.00 11.00 CH33-48 G61MPV-60C-091 3229320
13ACX-048-230 + TXV 47,500 13.50 11.00 CH33-48 G61MPV-60C-110 3229415
13ACX-048-230 + TXV 47,500 13.50 11.00 CH33-48 G61MPV-60C-111 3229321
NOTES:
+ TXV = Matched with Thermostatic Expansion Valve.
+ RFC = Matched with RFC metering device.
Ratings are certified in accordance with USE certification program which is based on AHRI Standard 210/240; 95°F outdoor air temperature, 80°F db / 67°F wb entering
evaporator air with 25 ft. of connecting refrigerant lines.
All ratings include the use of a blower time delay relay (TDR). All Lennox variable-speed furnaces and Air Handlers have time delay capabilities. Other Furnaces and Air
Handlers may require an optional time delay relay (58M81) for field installation. See furnace or air handler specifications to determine if relay is needed.
*Most popular combination.
Also see Expansion Valve Kit Usage Table.

13ACX - 1.5 to 5 Ton Air Conditioner / Page 29


AHRI SYSTEM MATCHES
NOTE - For the latest up-to-date system matches please visit the AHRI web site at http://www.ahridirectory.org
Model Coil or AHRI
Capacity SEER EER Furnace
No. Air Handler Reference
13ACX-048-230 + TXV 47,500 13.50 11.00 CH33-48 G71MPP-60C-110 3229441
13ACX-048-230 + TXV 47,000 13.00 11.00 CH33-48 3229290
13ACX-048-230 + TXV 48,500 14.00 11.60 CH33-49 G60UHV-60C-090 3229336
13ACX-048-230 + TXV 48,500 14.00 11.60 CH33-49 G60UHV-60C-110 3229340
13ACX-048-230 + TXV 48,500 14.00 11.60 CH33-49 G61MPV-60C-090 3229341
13ACX-048-230 + TXV 48,500 13.50 11.00 CH33-49 G61MPV-60C-091 3229348
13ACX-048-230 + TXV 48,500 14.00 11.60 CH33-49 G61MPV-60C-110 3229337
13ACX-048-230 + TXV 48,500 14.00 11.60 CH33-49 G61MPV-60C-111 3229349
13ACX-048-230 + TXV 48,500 14.00 11.60 CH33-49 G71MPP-60C-110 3229434
13ACX-048-230 + TXV 48,000 13.50 11.00 CH33-49 3229303
13ACX-048-230 + TXV 48,500 14.00 11.60 CH33-50/60C G60UHV-60C-090 3229372
13ACX-048-230 + TXV 48,000 14.00 11.60 CH33-50/60C G60UHV-60C-110 3229384
13ACX-048-230 + TXV 48,000 13.50 11.60 CH33-50/60C G61MPV-60C-090 3229403
13ACX-048-230 + TXV 48,000 13.50 11.00 CH33-50/60C G61MPV-60C-091 3229322
13ACX-048-230 + TXV 48,000 13.50 11.60 CH33-50/60C G61MPV-60C-110 3229416
13ACX-048-230 + TXV 48,000 13.50 11.00 CH33-50/60C G61MPV-60C-111 3229323
13ACX-048-230 + TXV 48,000 13.50 11.60 CH33-50/60C G71MPP-60C-110 3229442
13ACX-048-230 + TXV 48,000 13.50 11.00 CH33-50/60C 3229291
13ACX-048-230 + TXV 48,000 14.00 11.50 CH33-60D G60UHV-60D-135 3229393
13ACX-048-230 + TXV 48,000 14.00 11.60 CH33-60D G61MPV-60D-135 3229421
13ACX-048-230 + TXV 48,000 14.00 11.60 CH33-60D G71MPP-60D-135 3229447
13ACX-048-230 + TXV 47,500 13.00 11.00 CH33-60D 3229292
13ACX-048-230 + TXV 48,500 14.00 11.60 CH33-62D G60UHV-60C-090 3229338
13ACX-048-230 + TXV 48,500 14.00 11.60 CH33-62D G60UHV-60C-110 3229342
13ACX-048-230 + TXV 48,500 14.00 12.00 CH33-62D G60UHV-60D-135 3229394
13ACX-048-230 + TXV 48,500 14.00 11.60 CH33-62D G61MPV-60C-090 3229343
13ACX-048-230 + TXV 48,500 13.50 11.60 CH33-62D G61MPV-60C-091 3229350
13ACX-048-230 + TXV 48,500 14.00 11.60 CH33-62D G61MPV-60C-110 3229339
13ACX-048-230 + TXV 48,500 14.00 11.60 CH33-62D G61MPV-60C-111 3229351
13ACX-048-230 + TXV 48,500 14.00 11.60 CH33-62D G61MPV-60D-135 3229422
13ACX-048-230 + TXV 48,500 14.00 11.60 CH33-62D G71MPP-60C-110 3229435
13ACX-048-230 + TXV 48,500 14.00 11.60 CH33-62D G71MPP-60D-135 3229448
13ACX-048-230 + TXV 48,000 13.50 11.00 CH33-62D 3229304
13ACX-048-230 + TXV 47,000 13.50 11.00 CR33-50/60 G60DFV-60C-090 3229363
13ACX-048-230 + TXV 46,500 13.50 11.00 CR33-50/60 G60DFV-60C-110 3229364
13ACX-048-230 + TXV 46,500 13.50 11.00 CR33-50/60 G61MPV-60C-090 3229404
13ACX-048-230 + TXV 46,500 13.40 11.00 CR33-50/60 G61MPV-60C-091 3229324
13ACX-048-230 + TXV 46,500 13.50 11.00 CR33-50/60 G61MPV-60C-110 3229417
13ACX-048-230 + TXV 46,500 13.50 11.00 CR33-50/60 G61MPV-60C-111 3229325
13ACX-048-230 + TXV 46,500 13.50 11.00 CR33-50/60 G71MPP-60C-110 3229443
13ACX-048-230 + TXV 46,000 13.00 10.50 CR33-50/60 3229293
13ACX-048-230 + TXV 47,000 13.50 11.60 CR33-60 G60DFV-60D-135 3229365
13ACX-048-230 + TXV 46,500 13.50 11.00 CR33-60 G61MPV-60D-135 3229423
13ACX-048-230 + TXV 46,500 13.50 11.00 CR33-60 G71MPP-60D-135 3229449
13ACX-048-230 + TXV 46,000 13.00 10.50 CR33-60 3229294
13ACX-048-230 + TXV 47,500 13.50 11.60 CX34-38 G60UHV-60C-090 3229373
13ACX-048-230 + TXV 47,000 13.50 11.00 CX34-38 G60UHV-60C-110 3229385
NOTES:
+ TXV = Matched with Thermostatic Expansion Valve.
+ RFC = Matched with RFC metering device.
Ratings are certified in accordance with USE certification program which is based on AHRI Standard 210/240; 95°F outdoor air temperature, 80°F db / 67°F wb entering
evaporator air with 25 ft. of connecting refrigerant lines.
All ratings include the use of a blower time delay relay (TDR). All Lennox variable-speed furnaces and Air Handlers have time delay capabilities. Other Furnaces and Air
Handlers may require an optional time delay relay (58M81) for field installation. See furnace or air handler specifications to determine if relay is needed.
*Most popular combination.
Also see Expansion Valve Kit Usage Table.

13ACX - 1.5 to 5 Ton Air Conditioner / Page 30


AHRI SYSTEM MATCHES
NOTE - For the latest up-to-date system matches please visit the AHRI web site at http://www.ahridirectory.org
Model Coil or AHRI
Capacity SEER EER Furnace
No. Air Handler Reference
13ACX-048-230 + TXV 47,000 13.50 11.00 CX34-38 G61MPV-60C-090 3229405
13ACX-048-230 + TXV 47,000 13.00 11.00 CX34-38 3229295
13ACX-048-230 + TXV 48,000 14.00 11.60 CX34-43 G60UHV-60C-090 3229374
13ACX-048-230 + TXV 47,500 14.00 11.60 CX34-43 G60UHV-60C-110 3229386
13ACX-048-230 + TXV 47,500 13.50 11.60 CX34-43 G61MPV-60C-090 3229406
13ACX-048-230 + TXV 47,500 13.50 11.00 CX34-43 G61MPV-60C-091 3229326
13ACX-048-230 + TXV 47,500 13.50 11.00 CX34-43 G61MPV-60C-111 3229327
13ACX-048-230 + TXV 47,500 13.00 11.00 CX34-43 3229296
13ACX-048-230 + TXV 49,000 14.00 11.60 CX34-49 G60UHV-60C-090 3229375
13ACX-048-230 + TXV 48,500 14.00 11.60 CX34-49 G60UHV-60C-110 3229387
13ACX-048-230 + TXV 48,500 14.00 11.60 CX34-49 G61MPV-60C-090 3229407
13ACX-048-230 + TXV 48,500 13.50 11.60 CX34-49 G61MPV-60C-091 3229328
13ACX-048-230 + TXV 48,500 14.00 11.60 CX34-49 G61MPV-60C-111 3229329
13ACX-048-230 + TXV 48,000 13.50 11.00 CX34-49 3229297
13ACX-048-230 + TXV 47,500 13.50 11.60 CX34-50/60C G60UHV-60C-090 3229376
13ACX-048-230 + TXV 47,500 13.50 11.60 CX34-50/60C G60UHV-60C-110 3229388
13ACX-048-230 + TXV 47,000 13.50 11.00 CX34-50/60C G61MPV-60C-090 3229408
13ACX-048-230 + TXV 47,000 13.50 11.00 CX34-50/60C G61MPV-60C-091 3229330
13ACX-048-230 + TXV 47,000 13.50 11.00 CX34-50/60C G61MPV-60C-111 3229331
13ACX-048-230 + TXV 47,000 13.00 11.00 CX34-50/60C 3229298
13ACX-048-230 + TXV 48,500 14.00 12.00 CX34-60D G60UHV-60D-135 3229395
13ACX-048-230 + TXV 48,500 14.00 11.60 CX34-60D G61MPV-60D-135 3229424
13ACX-048-230 + TXV 48,500 14.00 11.60 CX34-60D G71MPP-60D-135 3229450
13ACX-048-230 + TXV 48,000 13.50 11.00 CX34-60D 3229299
13ACX-048-230 + TXV 49,500 14.00 11.60 CX34-62C G60UHV-60C-090 3229377
13ACX-048-230 + TXV 49,500 14.00 12.00 CX34-62C G60UHV-60C-110 3229389
13ACX-048-230 + TXV 49,000 14.00 11.60 CX34-62C G61MPV-60C-090 3229409
13ACX-048-230 + TXV 49,000 14.00 11.60 CX34-62C G61MPV-60C-091 3229332
13ACX-048-230 + TXV 49,500 14.00 11.60 CX34-62C G61MPV-60C-111 3229333
13ACX-048-230 + TXV 49,000 13.50 11.60 CX34-62C 3229300
13ACX-048-230 + TXV 49,000 14.00 12.00 CX34-62D G60UHV-60D-135 3229396
13ACX-048-230 + TXV 49,000 14.00 12.00 CX34-62D G61MPV-60D-135 3229425
13ACX-048-230 + TXV 49,000 14.00 12.00 CX34-62D G71MPP-60D-135 3229451
13ACX-048-230 + TXV 48,500 13.50 11.00 CX34-62D 3229301
13ACX-060-230 + RFC 60,000 13.50 11.00 C33-49 G60UHV-60C-090 3470194
13ACX-060-230 + RFC 60,000 13.00 11.00 C33-49 G60UHV-60C-110 3470195
13ACX-060-230 + RFC 59,500 13.00 11.00 C33-49 G61MPV-60C-110 3470196
13ACX-060-230 + RFC 59,500 13.00 11.00 C33-49 G71MPP-60C-110 3470197
13ACX-060-230 + RFC 59,500 13.00 11.00 C33-49 3470198
13ACX-060-230 + RFC 60,000 13.50 11.50 C33-60D G60UHV-60D-135 3470199
13ACX-060-230 + RFC 60,000 13.50 11.00 C33-60D G61MPV-60D-135 3470200
13ACX-060-230 + RFC 60,000 13.50 11.00 C33-60D G71MPP-60D-135 3470201
13ACX-060-230 + RFC 61,000 13.50 11.50 C33-62C G60UHV-60C-090 3470202
13ACX-060-230 + RFC 61,000 13.50 11.50 C33-62C G60UHV-60C-110 3470203
13ACX-060-230 + RFC 60,500 13.00 11.00 C33-62C G61MPV-60C-090 3470204
13ACX-060-230 + RFC 61,000 13.50 11.00 C33-62C G61MPV-60C-110 3470205
13ACX-060-230 + RFC 61,000 13.50 11.00 C33-62C G71MPP-60C-110 3470206
NOTES:
+ TXV = Matched with Thermostatic Expansion Valve.
+ RFC = Matched with RFC metering device.
Ratings are certified in accordance with USE certification program which is based on AHRI Standard 210/240; 95°F outdoor air temperature, 80°F db / 67°F wb entering
evaporator air with 25 ft. of connecting refrigerant lines.
All ratings include the use of a blower time delay relay (TDR). All Lennox variable-speed furnaces and Air Handlers have time delay capabilities. Other Furnaces and Air
Handlers may require an optional time delay relay (58M81) for field installation. See furnace or air handler specifications to determine if relay is needed.
*Most popular combination.
Also see Expansion Valve Kit Usage Table.

13ACX - 1.5 to 5 Ton Air Conditioner / Page 31


AHRI SYSTEM MATCHES
NOTE - For the latest up-to-date system matches please visit the AHRI web site at http://www.ahridirectory.org
Model Coil or AHRI
Capacity SEER EER Furnace
No. Air Handler Reference
13ACX-060-230 + RFC 61,000 13.00 11.00 C33-62C 3470207
13ACX-060-230 + RFC 61,000 13.50 11.60 C33-62D G60UHV-60D-135 3470208
13ACX-060-230 + RFC 60,500 13.50 11.50 C33-62D G61MPV-60D-135 3470209
13ACX-060-230 + RFC 60,000 13.00 11.00 C33-62D 3470210
13ACX-060-230 + RFC 60,500 13.50 11.50 CH23-68 G60UHV-60D-135 3470211
13ACX-060-230 + RFC 60,500 13.50 11.50 CH23-68 G61MPV-60D-135 3470212
13ACX-060-230 + RFC 60,500 13.50 11.50 CH23-68 G71MPP-60D-135 3470213
13ACX-060-230 + RFC 60,000 13.00 11.00 CH23-68 3470214
13ACX-060-230 + RFC 59,500 13.00 11.00 CH33-50/60C G60UHV-60C-090 3470215
13ACX-060-230 + RFC 59,500 13.00 11.00 CH33-50/60C G60UHV-60C-110 3470216
13ACX-060-230 + RFC 59,500 13.50 11.50 CH33-60D G60UHV-60D-135 3470217
13ACX-060-230 + RFC 59,500 13.00 11.00 CH33-60D G61MPV-60D-135 3470218
13ACX-060-230 + RFC 59,500 13.00 11.00 CH33-60D G71MPP-60D-135 3470219
13ACX-060-230 + RFC 59,500 13.50 11.00 CH33-62D G60UHV-60C-090 3470220
13ACX-060-230 + RFC 59,500 13.50 11.00 CH33-62D G60UHV-60C-110 3470221
13ACX-060-230 + RFC 59,500 13.50 11.50 CH33-62D G60UHV-60D-135 3470222
13ACX-060-230 + RFC 59,500 13.00 11.00 CH33-62D G61MPV-60C-090 3470223
13ACX-060-230 + RFC 59,500 13.00 11.00 CH33-62D G61MPV-60C-110 3470224
13ACX-060-230 + RFC 59,500 13.50 11.00 CH33-62D G61MPV-60D-135 3470225
13ACX-060-230 + RFC 59,500 13.00 11.00 CH33-62D G71MPP-60C-110 3470226
13ACX-060-230 + RFC 59,500 13.50 11.00 CH33-62D G71MPP-60D-135 3470227
13ACX-060-230 + RFC 59,500 13.00 11.00 CH33-62D 3470228
13ACX-060-230 + RFC 59,500 13.00 11.00 CR33-60 G60DFV-60D-135 3470229
13ACX-060-230 + RFC 59,000 13.00 11.00 CR33-60 G61MPV-60D-135 3470230
13ACX-060-230 + RFC 59,000 13.00 11.00 CR33-60 G71MPP-60D-135 3470231
13ACX-060-230 + TXV 60,000 13.50 11.00 C33-49 G60UHV-60C-090 3470111
13ACX-060-230 + TXV 60,000 13.50 11.00 C33-49 G60UHV-60C-110 3470112
13ACX-060-230 + TXV 60,000 13.00 11.00 C33-49 G61MPV-60C-110 3470113
13ACX-060-230 + TXV 59,500 13.00 11.00 C33-49 G61MPV-60C-111 3470114
13ACX-060-230 + TXV 60,000 13.00 11.00 C33-49 G71MPP-60C-110 3470115
13ACX-060-230 + TXV 60,000 13.50 11.50 C33-60D G60UHV-60D-135 3470116
13ACX-060-230 + TXV 60,000 13.50 11.50 C33-60D G61MPV-60D-135 3470117
13ACX-060-230 + TXV 60,000 13.50 11.50 C33-60D G71MPP-60D-135 3470118
13ACX-060-230 + TXV 61,000 13.50 11.50 C33-62C G60UHV-60C-090 3470119
13ACX-060-230 + TXV 60,500 13.50 11.50 C33-62C G60UHV-60C-110 3470120
13ACX-060-230 + TXV 60,500 13.50 11.00 C33-62C G61MPV-60C-090 3470121
13ACX-060-230 + TXV 60,500 13.00 11.00 C33-62C G61MPV-60C-091 3470122
13ACX-060-230 + TXV 61,000 13.50 11.50 C33-62C G61MPV-60C-110 3470123
13ACX-060-230 + TXV 60,500 13.50 11.00 C33-62C G61MPV-60C-111 3470124
13ACX-060-230 + TXV 61,000 13.50 11.50 C33-62C G71MPP-60C-110 3470125
13ACX-060-230 + TXV 60,000 14.00 11.50 C33-62D G60UHV-60D-135 3470126
13ACX-060-230 + TXV 60,000 13.50 11.50 C33-62D G61MPV-60D-135 3470127
13ACX-060-230 + TXV 60,000 13.50 11.50 C33-62D G71MPP-60D-135 3470128
13ACX-060-230 + TXV 61,000 13.50 11.50 CB26UH-060 3470129
13ACX-060-230 + TXV 59,500 13.50 11.00 CB27UH-060-230 3470130
13ACX-060-230 + TXV 57,500 13.00 11.00 CB30M-51P 3470131
13ACX-060-230 + TXV 59,000 13.00 11.00 CB30M-65P 3470132
NOTES:
+ TXV = Matched with Thermostatic Expansion Valve.
+ RFC = Matched with RFC metering device.
Ratings are certified in accordance with USE certification program which is based on AHRI Standard 210/240; 95°F outdoor air temperature, 80°F db / 67°F wb entering
evaporator air with 25 ft. of connecting refrigerant lines.
All ratings include the use of a blower time delay relay (TDR). All Lennox variable-speed furnaces and Air Handlers have time delay capabilities. Other Furnaces and Air
Handlers may require an optional time delay relay (58M81) for field installation. See furnace or air handler specifications to determine if relay is needed.
*Most popular combination.
Also see Expansion Valve Kit Usage Table.

13ACX - 1.5 to 5 Ton Air Conditioner / Page 32


AHRI SYSTEM MATCHES
NOTE - For the latest up-to-date system matches please visit the AHRI web site at http://www.ahridirectory.org
Model Coil or AHRI
Capacity SEER EER Furnace
No. Air Handler Reference
13ACX-060-230 + TXV 61,000 13.50 11.50 CBX26UH-060 3470135
13ACX-060-230 + TXV 59,500 13.50 11.00 CBX27UH-060-230 3470136
13ACX-060-230 + TXV 57,500 13.00 11.00 CBX32M-048 3470137
13ACX-060-230 + TXV 59,000 13.00 11.00 CBX32M-060 3470138
13ACX-060-230 + TXV 59,000 13.00 11.00 CBX32MV-048 3470139
13ACX-060-230 + TXV 59,000 13.00 11.00 CBX32MV-060 3470140
13ACX-060-230 + TXV 59,000 13.00 11.00 CBX40UHV-048 3470141
13ACX-060-230 + TXV 59,000 13.00 11.00 CBX40UHV-060 3470142
13ACX-060-230 + TXV 60,500 14.00 11.50 CH23-68 G60UHV-60D-135 3470143
13ACX-060-230 + TXV 60,500 13.50 11.50 CH23-68 G61MPV-60D-135 3470144
13ACX-060-230 + TXV 60,500 13.50 11.50 CH23-68 G71MPP-60D-135 3470145
13ACX-060-230 + TXV 60,000 13.00 11.00 CH23-68 3470146
13ACX-060-230 + TXV 59,500 13.00 11.00 CH33-50/60C G60UHV-60C-090 3470147
13ACX-060-230 + TXV 59,500 13.00 11.00 CH33-50/60C G60UHV-60C-110 3470148
13ACX-060-230 + TXV 59,500 13.00 11.00 CH33-50/60C G61MPV-60C-110 3470149
13ACX-060-230 + TXV 59,500 13.00 11.00 CH33-50/60C G61MPV-60C-111 3470150
13ACX-060-230 + TXV 59,500 13.00 11.00 CH33-50/60C G71MPP-60C-110 3470151
13ACX-060-230 + TXV 59,500 13.00 11.00 CH33-50/60C 3470152
13ACX-060-230 + TXV 59,500 13.50 11.50 CH33-60D G60UHV-60D-135 3470153
13ACX-060-230 + TXV 59,500 13.50 11.00 CH33-60D G61MPV-60D-135 3470154
13ACX-060-230 + TXV 59,500 13.50 11.00 CH33-60D G71MPP-60D-135 3470155
13ACX-060-230 + TXV 59,000 13.00 11.00 CH33-60D 3470156
13ACX-060-230 + TXV 60,000 13.50 11.50 CH33-62D G60UHV-60C-090 3470157
13ACX-060-230 + TXV 59,500 13.50 11.00 CH33-62D G60UHV-60C-110 3470158
13ACX-060-230 + TXV 60,500 13.50 11.50 CH33-62D G60UHV-60D-135 3470159
13ACX-060-230 + TXV 59,500 13.00 11.00 CH33-62D G61MPV-60C-090 3470160
13ACX-060-230 + TXV 59,500 13.00 11.00 CH33-62D G61MPV-60C-091 3470161
13ACX-060-230 + TXV 59,500 13.00 11.00 CH33-62D G61MPV-60C-110 3470162
13ACX-060-230 + TXV 59,500 13.00 11.00 CH33-62D G61MPV-60C-111 3470163
13ACX-060-230 + TXV 59,500 13.50 11.00 CH33-62D G61MPV-60D-135 3470164
13ACX-060-230 + TXV 59,500 13.00 11.00 CH33-62D G71MPP-60C-110 3470165
13ACX-060-230 + TXV 59,500 13.50 11.00 CH33-62D G71MPP-60D-135 3470166
13ACX-060-230 + TXV 59,500 13.00 11.00 CH33-62D 3470167
13ACX-060-230 + TXV 59,000 13.00 11.00 CR33-60 G60DFV-60D-135 3470168
13ACX-060-230 + TXV 58,500 13.50 11.00 CR33-60 G60UHV-60D-135 3470169
13ACX-060-230 + TXV 58,500 13.00 11.00 CR33-60 G61MPV-60D-135 3470170
13ACX-060-230 + TXV 58,500 13.00 11.00 CR33-60 G71MPP-60D-135 3470171
13ACX-060-230 + TXV 60,000 13.50 11.00 CX34-49 G60UHV-60C-090 3470172
13ACX-060-230 + TXV 60,000 13.50 11.00 CX34-49 G60UHV-60C-110 3470173
13ACX-060-230 + TXV 60,000 13.00 11.00 CX34-49 G61MPV-60C-110 3470174
13ACX-060-230 + TXV 59,500 13.00 11.00 CX34-49 G61MPV-60C-111 3470175
13ACX-060-230 + TXV 60,000 13.00 11.00 CX34-49 G71MPP-60C-110 3470176
13ACX-060-230 + TXV 59,500 13.00 11.00 CX34-49 3470177
13ACX-060-230 + TXV 60,000 13.50 11.50 CX34-60D G60UHV-60D-135 3470178
13ACX-060-230 + TXV 60,000 13.50 11.50 CX34-60D G61MPV-60D-135 3470179
13ACX-060-230 + TXV 60,000 13.50 11.50 CX34-60D G71MPP-60D-135 3470180
13ACX-060-230 + TXV 59,500 13.00 11.00 CX34-60D 3470181
NOTES:
+ TXV = Matched with Thermostatic Expansion Valve.
+ RFC = Matched with RFC metering device.
Ratings are certified in accordance with USE certification program which is based on AHRI Standard 210/240; 95°F outdoor air temperature, 80°F db / 67°F wb entering
evaporator air with 25 ft. of connecting refrigerant lines.
All ratings include the use of a blower time delay relay (TDR). All Lennox variable-speed furnaces and Air Handlers have time delay capabilities. Other Furnaces and Air
Handlers may require an optional time delay relay (58M81) for field installation. See furnace or air handler specifications to determine if relay is needed.
*Most popular combination.
Also see Expansion Valve Kit Usage Table.

13ACX - 1.5 to 5 Ton Air Conditioner / Page 33


AHRI SYSTEM MATCHES
NOTE - For the latest up-to-date system matches please visit the AHRI web site at http://www.ahridirectory.org
Model Coil or AHRI
Capacity SEER EER Furnace
No. Air Handler Reference
13ACX-060-230 + TXV 61,000 13.50 11.50 CX34-62C G60UHV-60C-090 3470182
13ACX-060-230 + TXV 60,500 13.50 11.50 CX34-62C G60UHV-60C-110 3470183
13ACX-060-230 + TXV 60,500 13.50 11.00 CX34-62C G61MPV-60C-090 3470184
13ACX-060-230 + TXV 60,500 13.00 11.00 CX34-62C G61MPV-60C-091 3470185
13ACX-060-230 + TXV 61,000 13.50 11.50 CX34-62C G61MPV-60C-110 3470186
13ACX-060-230 + TXV 60,500 13.50 11.00 CX34-62C G61MPV-60C-111 3470187
13ACX-060-230 + TXV 61,000 13.50 11.50 CX34-62C G71MPP-60C-110 3470188
13ACX-060-230 + TXV 61,000 13.50 11.00 CX34-62C 3470189
13ACX-060-230 + TXV 60,000 14.00 11.50 CX34-62D G60UHV-60D-135 3470190
13ACX-060-230 + TXV 60,000 13.50 11.50 CX34-62D G61MPV-60D-135 3470191
13ACX-060-230 + TXV 60,000 13.50 11.50 CX34-62D G71MPP-60D-135 3470192
13ACX-060-230 + TXV 60,000 13.00 11.00 CX34-62D 3470193
NOTES:
+ TXV = Matched with Thermostatic Expansion Valve.
+ RFC = Matched with RFC metering device.
Ratings are certified in accordance with USE certification program which is based on AHRI Standard 210/240; 95°F outdoor air temperature, 80°F db / 67°F wb entering
evaporator air with 25 ft. of connecting refrigerant lines.
All ratings include the use of a blower time delay relay (TDR). All Lennox variable-speed furnaces and Air Handlers have time delay capabilities. Other Furnaces and Air
Handlers may require an optional time delay relay (58M81) for field installation. See furnace or air handler specifications to determine if relay is needed.
*Most popular combination.
Also see Expansion Valve Kit Usage Table.
REVISIONS
Specifications Updated electrical data for -018-024-030-036-048-060

Visit us at www.lennox.com
For the latest technical information, www.lennoxdavenet.com
Contact us at 1-800-4-LENNOX

NOTE - Due to Lennox’ ongoing commitment to quality, Specifications, Ratings and Dimensions subject to change without notice and without incurring liability.
Improper installation, adjustment, alteration, service or maintenance can cause property damage or personal injury.
Installation and service must be performed by a qualified installer and servicing agency. ©2009 Lennox Industries, Inc.

You might also like