Location via proxy:   [ UP ]  
[Report a bug]   [Manage cookies]                

42U - CCTV Equipment Room

Download as pdf or txt
Download as pdf or txt
You are on page 1of 9

Server & Networking Cabinets 1200kg

General Technical Datasheet


Welded Cabinets for Server and LAN applications
ESN Series

Application

Belden Enclosures for use in 19” Data, Telecommunications, LAN and Server applications. Varying depths are available
for various applications.

Features
 4 Sliding vertical rails for mounting (6 rails for cabinets deeper than 800 mm).
 Main grounding point is on the bottom of the enclosure by one M8 screw.
 Top cover has knockout cut-outs for fan-unit and various cable entries.
 The frame is connected to the removable parts with grounding wires.
 The maximum permissible load is 1200kg and 20kg on the doors.
 The 800mm wide cabinet can be upgraded to bear 1500kg.
 Optional cable routing sides for between cabinets.
 Optional lacing panel and PDU holder.
 IP20 protection.
TDS ESN Series
Version CONCEPT 3
Date October 2016
Page 2 of 9

General

European standards
European standards: EN 62208 ed.2:2011

Installation of the cabinet


 It is necessary to distribute the load equally to ensure the maximum recommended load.
 The cabinet must be installed on a flat floor and adjust any differences using the levelling feet.
 To avoid dust penetration at the cable entries use the blanking panel with brush or protective frame.

Environmental protection
All parts are made of recyclable materials and after decommissioning the cabinet must be disposed of according to
relevant regulations.

Operating conditions

Operating environment:
 Office, Telecomm room, computing room.
 The cabinet is not intended for outdoor installation; or for installations in environment that can negatively influence the
functionality of the cabinet and the mounted devices (e.g. environment with the danger of explosion).

Must be protected against:


 Mechanical damage.
 Improper handling.
 A different usage than the cabinet is intended for.

Improper handling is especially:


 Overloading (exceeding the maximum recommended load).
 Installing devices which may negatively influence the operation and function of the cabinet or the installed equipment.
 Change of the construction or design of the cabinet.

Construction

The welded enclosures are available in widths 600mm for 19” mounting equipment and in 800mm width for 19”, 21” or
23” mounting equipment. The maximum load capacity is 1200kg. The minimum thickness of the surface coating finish is
65μm.

Material
 Strengthened frame: Cold-rolled steel 1.3 mm.
 Sliding rail (fixed at four points): Cold-rolled steel 2.5 mm.
 Side panels and doors: 1.0mm

Figure 1 800mm wide cabinet Figure 2 Flex frame for installation of19", 21" or 23"
TDS ESN Series
Version CONCEPT 3
Date October 2016
Page 3 of 9

Frame
Enlarged frame rails allow installation of lacing panel accessory for PDU and cable management.

Figure 4 Wide frame Figure 3 Lacing panel accessory installed

Figure 5 - Accessory Front-Rear cable management Figure 6 - Perforated frame for additional
accessories

Figure 7 Laser Unit marking


TDS ESN Series
Version CONCEPT 3
Date October 2016
Page 4 of 9

Door types
Door types are available in single (standard left side opening) or double doors. The maximum load on the door is 20 kg.
 Solid Steel door with rigid design.
 Glass door with safety tempered glass of 4 mm.
 Perforated door with 80% airflow with mesh pattern.
Rear panel
The standard enclosure comes with a rear solid panel. In case easy rear access is required, door types can be selected.

Side panels & Baying


Removable side panels are installed on metal pins on bottom of the frame and secured by a key locking mechanism.
They can be easily removed by unclicking grounding wires instantly. When cabinets are bayed together in a row,
knockout panels can be removed for easy cable management in between cabinets.

Figure 8 - Two side panels with locking mechanisms

Figure 9 Two side panels with locking mechanisms and additional Cable knock-out panels for between-
cabinet cable management
TDS ESN Series
Version CONCEPT 3
Date October 2016
Page 5 of 9

Top and bottom cover


Each enclosure is supplied with a top and bottom cover which is prepared to receive a Fan unit by removing knock-out
panel. On the front and rear of the cover knock-outs are pre-cut to enable cable access.

Figure 10 Multiple knock-outs for fan and cable Figure 11 Protective edge for cable entry

Figure 12 Top view 600mm wide Figure 13 Top view 800mm wide

Color
Available in Jet black (RAL9005) and Light grey (RAL7035).

Grounding
Ground wires are provided in the standard package. By use of click on studs and connectors, side panels and doors are
removed quick and easy. These need to be properly fixed and inserted into connectors during all the time when using the
cabinet.
TDS ESN Series
Version CONCEPT 3
Date October 2016
Page 6 of 9

Reinforcement upgrade kit from 1200kg to 1500kg and stability frame

For the ESN cabinets with a width of 800mm and a height of 37RU and above an upgrade kit is available to extend the
maximum permissible load from 1200kg to 1500kg (EDASR***). The stability frame is a recommended reinforcement for
extra stability when the 800mm Cabinet is standing alone (not bayed) and is loaded multiple sliding servers.

Vertical rail reinforcement strength member


The closed profile (2 mm cold-rolled steel) increases the load capacity of the 800 mm width cabinet up to 1500 kg.

Figure 14 EDASR strength member

EPN Full description BPCS and Label


EDASR037 ESN Reinforcement kit 37U Upgrade 1500kg
EDASR042 ESN Reinforcement kit 42U Upgrade 1500kg
EDASR045 ESN Reinforcement kit 45U Upgrade 1500kg
EDASR047 ESN Reinforcement kit 47U Upgrade 1500kg

Stability frame incl. cable management


The reinforcement kit is for 800mm wide ESN cabinets which to provide
extra stability when standing alone and provides cable management.

Figure 15 EDASC stability frame and cable management

Accessory Cabinet Type Depth


Accessory for Stability frame & 6 600mm
EDA C
EMEA Cabinets cable manager 8 800mm
9 900mm
1 1000mm
0 1100mm
2 1200mm

EDA S C 8 42

Cabinet Range Height *


S ESN 37 37RU - 1750mm
42 42RU - 1970mm
45 45RU - 2105mm
47 47RU - 2194mm
TDS ESN Series
Version CONCEPT 3
Date October 2016
Page 7 of 9

Dimensions

Width (mm) 600


Height (RU) 37 42 45 47
A - Height Outer Dimension (mm) 1750 1970 2105 2194
B - Height Inner Door Opening (mm) 1648 1868 2003 2092
C - Width Inner Door Opening (mm) 487
Maximum recommended load (kg) 1200kg
Maximum recommended load (kg)
-
with strengthening kit
Weight (kg)
600 83,9 92,0 96,1 98,7
800 95,6 104,5 108,9 111,9
900 101,3 110,5 115,2 118,3
E - Depth (mm)
1000 107,2 116,7 121,7 124,9
1100 113,7 123,6 128,7 132,1
1200 117,7 129,9 135,3 138,7

Width (mm) 800


Height (RU) 15 18 22 27 32 37 42 45 47
A - Height Outer Dimension (mm) 770 900 1080 1300 1525 1750 1970 2105 2194
B - Height Inner Door Opening (mm) 668 798 978 1198 1423 1648 1868 2003 2092
C - Width Inner Door Opening (mm) 687
Maximum recommended load (kg) 1200kg
Maximum recommended load (kg)
- 1500kg
with strengthening kit
Weight (kg)
600 55,7 60,3 66,7 74,6 82,5 93,9 102,8 107,3 110,2
800 65,8 70,9 79,1 86,4 95,1 107,2 116,9 121,8 125,1
900 70,5 75,8 83,0 92,0 101,1 113,6 123,6 128,7 132,2
E - Depth (mm)
1000 75,2 88,2 97,5 107,0 119,8 130,2 135,6 139,2 126,0
1100 79,7 85,1 92,9 102,6 112,4 125,6 136,4 142,0 145,7
1200 83,9 89,8 98,0 108,0 118,2 129,9 142,9 148,7 152,6

Table 1 - Dimensions
TDS ESN Series
Version CONCEPT 3
Date October 2016
Page 8 of 9

Delivery

The standard package consists of:


Amount Delivered Accessory
2x Keys for doors, rear & side panels
16x Cage nut sets
1x Blanking panel with brush
1 meter Plastic flex strip for cable entry edge
4x Adjustable feet

Ordering information

Cabinet Type Width Depth Top Cover Bottom Cover Side Panel
Server Networking 6 600 mm 6 600mm Cable Entry and Cable Entry and 0 No Sides
ESN C C
1200kg 8 800 mm 8 800mm Fanunit knockout Fanunit knockout 1 One Side
*ESN 800W 37U+ 9 900mm 2 Both sides
Upgradable to 1 1000mm Extra Cable
1500kg 3
0 1100mm entries
2 1200mm

ESN 42 8 8 G V C C 2 G

Height * Front Door Rear Door Color


15 15RU - 770mm* S Solid left S Solid left B Black RAL 9005
18 18RU - 900mm* G Glass left G Glass left G Grey RAL 7035
22 22RU - 1080mm* P Perforated left P Perforated left
27 27RU - 1300mm* D Double Solid D Double Solid
32 32RU - 1525mm* L Double Glass L Double Glass
37 37RU - 1750mm V Double Perforated V Double Perforated
42 42RU - 1970mm A Solid right A Solid right
45 45RU - 2105mm B Glass right B Glass right
47 47RU - 2194mm C Perforated right C Perforated right
N No door R Removable panel
N No door

Notes
 ESN 800mm wide version with 37RU and above can be upgraded to 1500kg by ordering reinforcement kit EDASR.
 ESN 600mm wide version only available in 37RU and above.
 Perforated doors have 80% openings by Mesh pattern

Belden declares this product to be in compliance with the environmental regulations EU RoHS (Directive 2002/95/EC, 27
January 2003); this is valid for all material produced after the RoHS compliant date for this product.
TDS ESN Series
Version CONCEPT 3
Date October 2016
Page 9 of 9

You might also like