User's Guide: IBM System x3850 M2 and System x3950 M2 Types 7141 and 7233
User's Guide: IBM System x3850 M2 and System x3950 M2 Types 7141 and 7233
User's Guide: IBM System x3850 M2 and System x3950 M2 Types 7141 and 7233
User’s Guide
IBM System x3850 M2 and System x3950 M2
Types 7141 and 7233
User’s Guide
Note: Before using this information and the product it supports, read the information in “Notices,” on page 79, the Warranty
Information document, and the IBM Safety Information and Environmental Notices and User Guide documents on the
Documentation CD.
Appendix. Notices . . . . . . . . . . . . . . . . . . . . . . . 79
Trademarks . . . . . . . . . . . . . . . . . . . . . . . . . . 79
Important notes. . . . . . . . . . . . . . . . . . . . . . . . . 80
Particulate contamination . . . . . . . . . . . . . . . . . . . . . 81
Documentation format . . . . . . . . . . . . . . . . . . . . . . 81
Electronic emission notices . . . . . . . . . . . . . . . . . . . . 82
Federal Communications Commission (FCC) statement . . . . . . . . . 82
Industry Canada Class A emission compliance statement . . . . . . . . 82
Avis de conformité à la réglementation d’Industrie Canada . . . . . . . . 82
Australia and New Zealand Class A statement . . . . . . . . . . . . 82
United Kingdom telecommunications safety requirement. . . . . . . . . 82
European Union EMC Directive conformance statement . . . . . . . . . 83
Taiwanese Class A warning statement . . . . . . . . . . . . . . . 83
Germany Electromagnetic Compatibility Directive . . . . . . . . . . . 83
People's Republic of China Class A warning statement . . . . . . . . . 84
Japanese Voluntary Control Council for Interference (VCCI) statement . . . 84
Korean Class A warning statement . . . . . . . . . . . . . . . . 84
Index . . . . . . . . . . . . . . . . . . . . . . . . . . . . 85
iv IBM System x3850 M2 and System x3950 M2 Types 7141 and 7233: User’s Guide
Safety
Before installing this product, read the Safety Information.
Ennen kuin asennat tämän tuotteen, lue turvaohjeet kohdasta Safety Information.
Important:
Each caution and danger statement in this document is labeled with a number. This
number is used to cross reference an English-language caution or danger
statement with translated versions of the caution or danger statement in the Safety
Information document.
For example, if a caution statement is labeled “Statement 1,” translations for that
caution statement are in the Safety Information document under “Statement 1.”
Be sure to read all caution and danger statements in this document before you
perform the procedures. Read any additional safety information that comes with the
server or optional device before you install the device.
vi IBM System x3850 M2 and System x3950 M2 Types 7141 and 7233: User’s Guide
Statement 1:
DANGER
To Connect: To Disconnect:
Safety vii
Statement 2:
CAUTION:
When replacing the lithium battery, use only IBM Part Number 15F8409 or an
equivalent type battery recommended by the manufacturer. If your system has
a module containing a lithium battery, replace it only with the same module
type made by the same manufacturer. The battery contains lithium and can
explode if not properly used, handled, or disposed of.
Do not:
v Throw or immerse into water
v Heat to more than 100°C (212°F)
v Repair or disassemble
Statement 3:
CAUTION:
When laser products (such as CD-ROMs, DVD drives, fiber optic devices, or
transmitters) are installed, note the following:
v Do not remove the covers. Removing the covers of the laser product could
result in exposure to hazardous laser radiation. There are no serviceable
parts inside the device.
v Use of controls or adjustments or performance of procedures other than
those specified herein might result in hazardous radiation exposure.
DANGER
Some laser products contain an embedded Class 3A or Class 3B laser
diode. Note the following.
Laser radiation when open. Do not stare into the beam, do not view directly
with optical instruments, and avoid direct exposure to the beam.
viii IBM System x3850 M2 and System x3950 M2 Types 7141 and 7233: User’s Guide
Statement 4:
CAUTION:
Use safe practices when lifting.
Statement 5:
CAUTION:
The power control button on the device and the power switch on the power
supply do not turn off the electrical current supplied to the device. The device
also might have more than one power cord. To remove all electrical current
from the device, ensure that all power cords are disconnected from the power
source.
2
1
Safety ix
Statement 8:
CAUTION:
Never remove the cover on a power supply or any part that has the following
label attached.
Hazardous voltage, current, and energy levels are present inside any
component that has this label attached. There are no serviceable parts inside
these components. If you suspect a problem with one of these parts, contact
a service technician.
Statement 26:
CAUTION:
Do not place any object on top of rack-mounted devices.
Statement 27:
CAUTION:
Hazardous moving parts are nearby.
x IBM System x3850 M2 and System x3950 M2 Types 7141 and 7233: User’s Guide
Chapter 1. The System x3850 M2 and System x3950 M2 server
The IBM® System x3850 M2 and System x3950 M2 Types 7141 and 7233 servers
are 4-U1-high, high-performance servers. They are ideally suited for networking
environments that require superior microprocessor performance, efficient asset
management, flexibility, and large amounts of reliable data storage.
When they are available, you can purchase one or more SMP expansion kits to
interconnect System x3850 M2 and System x3950 M2 servers to create multi-node
configurations of two, three, or four nodes, for up to a 16-socket operation.
The server comes with a limited warranty. For information about the terms of the
warranty and getting service and assistance, see the Warranty Information
document.
You can obtain up-to-date information about the server and other IBM server
products at http://www.ibm.com/systems/x/.
Related documentation
This User’s Guide contains general information about the server, including how to
install supported optional devices and how to configure the server. The following
documentation also comes with the server:
v Installation Guide
This printed document contains instructions for setting up the server and basic
instructions for installing some optional devices.
v Warranty Information
This printed document contains information about the terms of the warranty.
v Safety Information
This document is in PDF on the IBM Documentation CD. It contains translated
caution and danger statements. Each caution and danger statement that appears
in the documentation has a number that you can use to locate the corresponding
statement in your language in the Safety Information document.
v Rack Installation Instructions
This printed document contains instructions for installing the server in a rack.
v Problem Determination and Service Guide
This document is in PDF on the IBM Documentation CD. It contains information
to help you solve problems yourself, and it contains information for service
technicians.
1. Racks are measured in vertical increments of 4.45 cm (1.75 inches) each. Each increment is called a ″U.″ A 1-U-high device is
1.75 inches tall.
The System x and xSeries Tools Center is an online information center that
contains information about tools for updating, managing, and deploying firmware,
device drivers, and operating systems. The System x and xSeries Tools Center is at
http://publib.boulder.ibm.com/infocenter/toolsctr/v1r0/index.jsp.
The server might have features that are not described in the documentation that
comes with the server. The documentation might be updated occasionally to include
information about those features, or technical updates might be available to provide
additional information that is not included in the server documentation. These
updates are available from the IBM Web site. To check for updated documentation
and technical updates, complete the following steps.
Note: Changes are made periodically to the IBM Web site. The actual procedure
might vary slightly from what is described in this document.
1. Go to http://www.ibm.com/systems/support/.
2. Under Product support, click System x.
3. Under Popular links, click Publications lookup.
4. From the Product family menu, select System x3850 M2 or System x3950 M2
and click Continue.
2 IBM System x3850 M2 and System x3950 M2 Types 7141 and 7233: User’s Guide
v Danger: These statements indicate situations that can be potentially lethal or
extremely hazardous to you. A danger statement is placed just before the
description of a potentially lethal or extremely hazardous procedure step or
situation.
4 IBM System x3850 M2 and System x3950 M2 Types 7141 and 7233: User’s Guide
Table 1. Features and specifications
Microprocessor: Upgradeable microcode: Environment:
v Intel® Xeon® multi-core microprocessor v Air temperature:
with 8 MB Level-2 cache System BIOS, FPGA, diagnostics, service – Server on:
v 1066 MHz front-side bus (FSB) processor, BMC, and SAS microcode - 10° to 35°C (50° to 95°F); altitude:
v Single node minimum: One 0 to 914 m (3000 ft). If the server
microprocessor per core Power supply: has a dual-core microprocessor, at
v Multi-node minimum: One v Standard: One or two dual-rated power maximum power reduce the 35°C
microprocessor per core in each node supplies, depending on the model by 1°C per 300 m above sea level,
v Support for up to four microprocessors – 1440 watts at 220 V ac input or the microprocessor might throttle
– 720 watts at 110 V ac input to remain within the internal thermal
Note: Use the Configuration/Setup Utility specifications.
v Hot-swappable and redundant at 220 V
program to determine the type and speed - 10° to 32°C (50° to 90°F); altitude:
ac, only with two power supplies
of the microprocessors. 914 m to 2133 m (7000 ft).
v If the server is operating at 110 V ac, a – Server off: 10° to 43°C (50.0° to
Memory: second power supply must be installed 109.4°F); maximum altitude: 2133 m
v Single-node minimum: 2 GB depending to maintain a fully functional server. (6998.0 ft)
on server model, expandable to 256 GB v Humidity:
v Multi-node minimum: 4 GB in node 1 Size:
– Server on: 8% to 80%
and 2 GB in all other modes expandable v 4U
– Server off: 8% to 80%
to a total of 1 TB v Height: 128.35 mm (5.05 in.)
v Particulate contamination:
v Type: Registered, ECC, PC2-5300 v Depth: 715 mm (28.15 in.)
v Width: 440 mm (17.32 in.) Attention: Airborne particulates and
double data rate (DDR) II, SDRAM
v Weight: approximately 43.1 kg (95 lb) reactive gases acting alone or in
v Sizes: 1 GB, 2 GB, 4 GB or 8 GB (when
when fully configured or 31.75 kg (70 combination with other environmental
available) in pairs
lb) minimum factors such as humidity or temperature
v Connectors: Two-way interleaved, eight
might pose a risk to the server. For
dual inline memory module (DIMM)
Integrated functions: information about the limits for
connectors per memory card
v Baseboard management controller particulates and gases, see “Particulate
v Maximum: Four memory cards, each
v IBM EXA-4 chip set with integrated contamination” on page 81.
card containing four pairs of PC2-5300
DDR II DIMMs memory and I/O controller
v Remote Supervisor Adapter II Heat output:
Drives: v Light path diagnostics
Approximate heat output:
v Slim DVD-ROM: IDE and SATA (optional v Six Universal Serial Bus (USB) ports v Minimum configuration: 1297 Btu (380
in some models) (2.0)
– Three on rear of server watts) per hour
v Serial Attached SCSI (SAS) hard disk v Typical configuration: 2730 Btu (800
drives – Two on front of server
– One internal watts) per hour
v Broadcom 5709 dual 10/100/1000 v Maximum configuration:
Expansion bays:
Gigabit Ethernet controller – 5527 Btu per hour (1620 watts) at 110
v Four SAS, 2.5-inch bays
v ATI RN50 video V ac
v One 12.7 mm removable-media drive
– 16 MB video memory – 5425 Btu per hour (1590 watts) at 220
bay (DVD drive installed, standard on
– SVGA compatible V ac
some models only)
v Serial-attached SCSI (SAS) controller
Electrical input:
Expansion slots: with RAID capabilities
v Sine-wave input (50 - 60 Hz) required
v Support for ServeRAID-MR10k SAS
Seven PCI Express x8 (half-length) slots: v Input voltage low range:
controller
– Minimum: 100 V ac
v Five non-hot-swap v Serial connector
v Two hot-swap – Maximum: 127 V ac
v SMP Expansion Ports
v Input voltage high range:
Acoustical noise emissions: – Minimum: 200 V ac
v Sound power, idle: 6.6 bel declared – Maximum: 240 V ac
v Sound power, operating: 6.6 bel v Approximate input kilovolt-amperes (kVA):
declared – Minimum: 0.39 kVA
– Typical: 0.8 kVA
– Maximum: 1.65 kVA
Note: In messages and documentation, the term service processor refers to the
baseboard management controller or the Remote Supervisor Adapter II.
v IBM Director
IBM Director is a workgroup-hardware-management tool that you can use to
centrally manage IBM System x and xSeries® servers. For more information, see
the IBM Director documentation on the IBM Director CD.
v IBM Electronic Service Agent
IBM Electronic Service Agent is a software tool that monitors the server for
hardware error events and automatically submits electronic service requests to
the IBM Support Center. Also, it can collect and transmit system configuration
information on a scheduled basis so that the information is available to you and
your support representative. It uses minimal system resources, is available free
of charge, and can be downloaded from the Web. For more information and to
download Electronic Service Agent, go to http://www.ibm.com/support/electronic/.
v IBM Enterprise X-Architecture technology
IBM X-Architecture technology combines proven, innovative IBM designs to make
your x86-processor-based server powerful, scalable, and reliable. For more
information, see http://www.ibm.com/servers/eserver/xseries/xarchitecture/
enterprise/index.html.
– Active™ Memory
The Active Memory feature improves the reliability of memory through
online-spare memory, memory mirroring, and memory scrubbing. Online-spare
memory disables a failed pair of DIMMs from the server configuration and
activates a pair of online-spare DIMMs. Memory scrubbing is an automatic
daily test of all the system memory that detects and reports memory errors
that might develop, before they cause a server outage.
– Large system-memory capacity
The server supports up to 256 GB of system memory. The memory controller
supports error correcting code (ECC) for up to 32 industry-standard
PC2-5300, 1.8 V, 240-pin, registered, double-data-rate (DDR) II, synchronous
dynamic random access memory (SDRAM) dual inline memory modules
(DIMMs).
– Memory ProteXion
The Memory ProteXion feature provides the equivalent of a hot-spare drive in
a RAID array. It is based in the memory controller, and it enables the server to
sense when a chip on a DIMM has failed and to route the data around the
failed chip.
v IBM ServerGuide Setup and Installation CD
The ServerGuide Setup and Installation CD that comes with the server provides
programs to help you set up the server and install a Windows operating system.
6 IBM System x3850 M2 and System x3950 M2 Types 7141 and 7233: User’s Guide
The ServerGuide program detects installed optional hardware devices and
provides the correct configuration programs and device drivers. For more
information about the ServerGuide Setup and Installation CD, see “Using the
ServerGuide Setup and Installation CD” on page 68.
v Integrated network support
The server comes with an integrated Broadcom 5709 dual Gigabit Ethernet
controller, which supports connection to a 10 Mbps, 100 Mbps, or 1000 Mbps
network. For more information, see “Configuring the Gigabit Ethernet controller”
on page 70.
v Integrated Trusted Platform Module (TPM)
This integrated security chip performs cryptographic functions and stores private
and public secure keys. It provides the hardware support for the Trusted
Computing Group (TCG) specification. You can download the software to support
the TCG specification, when the software is available. See http://www.ibm.com/
servers/eserver/xseries/scalable_family.html for details about the TPM
implementation.
v Large data-storage capacity and hot-swap capability
The server supports up to four 1-inch (26 mm) slim-high, 2.5-inch hot-swap hard
disk drives that are connected to the SAS backplane. With the hot-swap feature,
you can add, remove, or replace hard disk drives without turning off the server.
v Light path diagnostics
Light path diagnostics provides LEDs to help you diagnose problems. For more
information, see the section about light path diagnostics in the Problem
Determination and Service Guide.
v PCI Express x8 adapter capabilities
The server has seven slots for PCI Express x8 adapters. These slots also accept
x4 adapters.
v Active Energy Manager
The IBM Active Energy Manager solution is an IBM Director extension that
measures and reports server power consumption as it occurs. This enables you
to monitor power consumption in correlation to specific software application
programs and hardware configurations. You can obtain the measurement values
through the systems-management interface and view them, using IBM Director.
For more information, including the required levels of IBM Director and Active
Energy Manager, see the IBM Director documentation on the IBM Director CD, or
go to http://www.ibm.com/servers/eserver/xseries/systems_management/
ibm_director /extensions/.
v Dynamic System Analysis (DSA) Preboot diagnostic programs
The DSA Preboot diagnostic programs are stored in integrated USB memory and
collect and analyze system information to aid in diagnosing server problems. The
diagnostic programs collect the following information about the server:
– System configuration
– Network interfaces and settings
– Installed hardware
– Light path diagnostics status
– Service processor status and configuration
– Vital product data, firmware, and BIOS configuration
– Hard disk drive health
– RAID controller configuration
– Event logs for ServeRAID controllers and service processors
The diagnostic programs create a merged log that includes events from all
collected logs. The information is collected into a file that you can send to the
8 IBM System x3850 M2 and System x3950 M2 Types 7141 and 7233: User’s Guide
v Service processor adapter for remote systems management
v Parity checking on the SAS bus and PCI Express buses
v Power managed and Advanced Configuration and Power Interface (ACPI)
compliant
v Power-on self-test (POST)
v Predictive Failure Analysis (PFA) alerts
v Redundant Ethernet capabilities (requires optional Ethernet adapter) with failover
support
v Redundant hot-swap capability
– Cooling fans with speed-sensing capability
– Power supplies
v Remind button to temporarily flash the system-error LED
v Remote system problem-determination support
v ROM-based diagnostic programs
v Standby voltage for systems-management features and monitoring
v Startup (boot) from LAN using Preboot Execution Environment (PXE) protocol
v System auto-configuring from the configuration menu
v System error logging
v Upgradeable microcode for POST, BIOS, diagnostics, service processor, and
read-only memory (ROM) resident code, locally or over the LAN
v Vital product data (VPD) on microprocessors, system boards, power supplies,
and SAS (hot-swap-drive) backplane
v Wake on LAN capability
IBM Director
With IBM Director, a network administrator can perform the following tasks:
v View the hardware configuration of remote systems, in detail
v Monitor the usage and performance of critical components, such as
microprocessors, disks, and memory
v Centrally manage individual or large groups of IBM and non-IBM
x86-processor-based servers, desktop computers, workstations, and notebook
computers on a variety of platforms
IBM Director also provides an extensible platform that supports advanced server
tools that are designed to reduce the total cost of managing and supporting
For more information about IBM Director, see the documentation on the IBM
Director CD that comes with the server, the IBM Director Information Center at
http://publib.boulder.ibm.com/infocenter/eserver/v1r2/topic/diricinfo_all/
diricinfoparent.html, and the IBM System x and xSeries Systems Management Web
page at http://www.ibm.com/systems/management/, which presents an overview of
IBM Systems Management and IBM Director.
10 IBM System x3850 M2 and System x3950 M2 Types 7141 and 7233: User’s Guide
Server controls, connectors, LEDs, and power
This section describes the controls, connectors, and light-emitting diodes (LEDs)
and how to turn the server on and off.
Front view
The following illustration shows the controls, LEDs, and connectors on the front of
the server.
Hard disk drive activity LED DVD-eject button
Hard disk drive status LED DVD drive activity LED
Operator information panel
USB connectors
1 2
3 4
Scalability LED
Electrostatic-discharge connector
Hard disk drive activity LED: On some server models, each hot-swap hard disk
drive has an activity LED. When this LED is flashing, it indicates that the drive is in
use.
Hard disk drive status LED: On some server models, each hot-swap hard disk
drive has a status LED. When this LED is lit continuously, that individual drive is
faulty. When the drive is connected to the integrated SAS controller with RAID
capabilities, a flashing status LED indicates that the drive is a secondary drive in a
mirrored pair and the drive is being synchronized.
DVD-eject button: Press this button to release a CD or DVD from the DVD drive.
DVD drive activity LED: When this LED is lit, it indicates that the DVD drive is in
use.
Operator information panel: This panel contains controls and LEDs. The following
illustration shows the controls and LEDs on the operator information panel.
Power-control button/power-on LED Information LED
Ethernet icon LED System-error LED
1 2
Power-control button cover Ethernet port activity LEDs Locator button/locator LED
The following controls and LEDs are on the operator information panel:
Note: If this LED is off, it does not mean that there is no electrical power in the
server. The LED might be burned out. To remove all electrical power from the
server, you must disconnect the power cords from the electrical outlets.
v Ethernet-icon LED: This LED lights the Ethernet icon.
v Ethernet activity LEDs: When these LEDs flash, they indicate that there is
activity between the server and the network on the indicated port.
v Locator LED: Use this LED to visually locate the server among other servers.
You can use IBM Director to light this LED remotely or press the locator button to
light the LED manually. This LED is also lit during startup.
In multi-node configurations, when this LED flashes, it indicates that the server is
the primary node. When this LED is lit continuously, it indicates that the server is
a secondary node.
v Locator button: Press this button to turn the locator LED on and off manually. In
multi-node configurations, press this button to turn the locator LED on and off in
all nodes in the configuration.
v Information LED: When this LED is lit, it indicates that there is a suboptimal
condition in the server and that light path diagnostics will light an additional LED
to help isolate the condition. This LED and LEDs on the light path diagnostics
panel remain lit until you resolve the condition or you press the remind button.
v System-error LED: When this LED is lit, it indicates that a system error has
occurred. An LED on the light path diagnostics panel is also lit to help isolate the
error.
Scalability LED: When this LED is lit, it indicates that an optional scalability key is
installed in the server, which enables support for connecting the server to other
servers to form multi-node configurations.
12 IBM System x3850 M2 and System x3950 M2 Types 7141 and 7233: User’s Guide
Rear view
The following illustration shows the connectors and LEDs on the rear of the server.
Gigabit
Ethernet 2 LED Gigabit
Gigabit Ethernet 2 Ethernet 1 LED
Gigabit Ethernet 1
System-error LED
Power-on LED Locator LED Remote Supervisor Adapter II
Power
supply 1
AC power
DC power
Power-
supply error
USB
SAS
Power
supply 2
System serial
SMP Expansion Port 1
link LED SMP Expansion Port 3
SMP Expansion Port 1
SMP Expansion Port 3
SMP Expansion Port 2 link LED
link LED
SMP Expansion Port 2
Power-on LED: When this LED is lit and not flashing, it indicates that the server is
turned on. When this LED is flashing, it indicates that the server is turned off and
still connected to an ac power source. When this LED is off, it indicates that ac
power is not present or the power supply or the LED itself has failed.
Note: If this LED is off, it does not mean that there is no electrical power in the
server. The LED might be burned out. To remove all electrical power from the
server, you must disconnect the power cords from the electrical outlets.
Locator LED: Use this LED to visually locate the server among other servers. You
can use IBM Director to light this LED remotely or press the locator button to light
the LED manually. This LED is also lit during startup.
System-error LED: When this LED is lit, it indicates that a system error has
occurred. An LED on the light path diagnostics panel is also lit to help isolate the
error.
Gigabit Ethernet 2 LED: When this LED flashes, it indicates that there is activity
between the server and the network. When this LED is lit continuously, it indicates
that there is an active connection on the Ethernet port.
Gigabit Ethernet 1 LED: When this LED flashes, it indicates that there is activity
between the server and the network. When this LED is lit continuously, it indicates
that there is an active connection on the Ethernet port.
External power
supply connector
Ethernet connector
(RJ-45)
Video connector
The following controls, connectors, and LEDs are on the Remote Supervisor
Adapter II:
v Adapter activity LED: When this LED is flashing, the Remote Supervisor
Adapter II is functioning normally. When this LED is lit continuously, there is a
problem with the Remote Supervisor Adapter II. When the LED is off, the Remote
Supervisor Adapter II is not functioning.
v Power LED: When this LED is lit, the Remote Supervisor Adapter II is receiving
power from the server, or from an external power-supply.
v Reset button: (Trained service technician only) Insert and press the open end of
a paper clip (or similar object) into the recessed reset button to manually reset
the Remote Supervisor Adapter II.
v Mini-USB connector: This connector is not supported.
v Video connector: Use this connector to connect the server monitor.
v Ethernet connector (RJ45): Use this connector to connect a Category 3 (10
Mbps) or Category 5 (100 Mbps) Ethernet cable to enable a LAN connection.
v External power-supply connector: Use this connector to connect an external
power-supply to the Remote Supervisor Adapter II.
v ASM connector: This connector is not supported.
14 IBM System x3850 M2 and System x3950 M2 Types 7141 and 7233: User’s Guide
AC power LED: This green LED provides status information about the power
supply. During typical operation, both the ac and dc power LEDs are lit. For any
other combination of LEDs, see the Problem Determination and Service Guide on
the IBM System x Documentation CD.
DC power LED: This green LED provides status information about the power
supply. During typical operation, both the ac and dc power LEDs are lit. For any
other combination of LEDs, see the Problem Determination and Service Guide on
the IBM System x Documentation CD.
Power-supply error LED: When this amber LED is lit, it indicates that there is an
error condition within the power supply. For more information, see the Problem
Determination and Service Guide on the IBM System x Documentation CD.
SMP Expansion Port 3 connector: Use this connector to connect the server to
other servers to form multi-node configurations (requires scalability enablement).
SMP Expansion Port 3 link LED: When this LED is lit, it indicates that there is an
active connection on SMP Expansion Port 3.
SMP Expansion Port 1 link LED: When this LED is lit, it indicates that there is an
active connection on SMP Expansion Port 1.
SMP Expansion Port 1 connector: Use this connector to connect the server to
other servers to form multi-node configurations (requires scalability enablement).
SMP Expansion Port 2 link LED: When this LED is lit, it indicates that there is an
active connection on SMP Expansion Port 2.
SMP Expansion Port 2 connector: Use this connector to connect the server to
other servers to form multi-node configurations (requires scalability enablement).
Some operating systems require an orderly shutdown before you turn off the server.
See your operating-system documentation for information about shutting down the
operating system.
Statement 5:
CAUTION:
The power control button on the device and the power switch on the power
supply do not turn off the electrical current supplied to the device. The device
also might have more than one power cord. To remove all electrical current
from the device, ensure that all power cords are disconnected from the power
source.
2
1
The server can be turned off in any of the following ways:
v You can turn off the server from the operating system, if your operating system
supports this feature. After an orderly shutdown of the operating system, the
server will be turned off automatically.
v You can press the power-control button to start an orderly shutdown of the
operating system and turn off the server, if your operating system supports this
feature.
16 IBM System x3850 M2 and System x3950 M2 Types 7141 and 7233: User’s Guide
v If the operating system stops functioning, you can press and hold the
power-control button for more than 4 seconds to turn off the server.
v If the server is installed in a static partition, pressing the power-control button on
the primary node in the partition will start an orderly shutdown of the operating
system and turn off the server.
v The server can be turned off from the Remote Supervisor Adapter II user
interface.
v If the Wake on LAN feature turned on the server, the Wake on LAN feature can
turn off the server.
v You can turn off the server through a request from the service processor.
Server components
The following illustrations show the major components in the server. The
illustrations in this document might differ slightly from your hardware.
Top cover
PCI divider
with battery holder
Adapter-retention
bracket
ServeRAID-MR10k
controller
PCI divider
PCI switch-card
assembly
Hot-swap power supply
20 IBM System x3850 M2 and System x3950 M2 Types 7141 and 7233: User’s Guide
Memory-card DIMM connectors
The following illustration shows the DIMM connectors on the memory card.
DIMM 1
DIMM 2
DIMM 3
DIMM 4
DIMM 5
DIMM 6
DIMM 7
DIMM 8
Memory-card LEDs
The following illustration shows the LEDs on the memory card.
Memory hot-swap enabled LED
Visible from top of
Memory-card/DIMM error LED memory card
Memory-card power LED
Memory-card only error LED
Fan 5
Fan 4 Fan 6
Fan 2
Fan 1 Fan 3
Microprocessor 3 Microprocessor 4
VRM 3 3 4 VRM 4
Microprocessor 1 Microprocessor 2
Memory card 1
1 2 Memory card 4
Memory card 3
Memory card 2 VRM 2
VRM 1
Scalability key
22 IBM System x3850 M2 and System x3950 M2 Types 7141 and 7233: User’s Guide
Microprocessor-board LEDs
The following illustration shows the LEDs on the microprocessor board.
FPGA heartbeat
LED
BMC heartbeat
Board LED
fault LED
Microprocessor 3 Microprocessor 4
error LED error LED
VRM 3 error LED 3 4 VRM 4 error LED
1 2
Microprocessor 1 Microprocessor 2
error LED error LED
VRM 1 error LED VRM 2 error LED
Table 2 describes the function of each status LED other than light path diagnostics
LEDs.
Table 2. Microprocessor-board status LEDs (other than light path diagnostics)
LED Description
BMC heartbeat When this LED is flashing, it indicates normal operation of the
baseboard management controller.
FPGA heartbeat When this LED is flashing, it indicates normal operation of the FPGA
(field-programmable gate array) chip.
Machine check When this LED is lit continuously, the server is prepared to capture a
machine check. When this LED is flashing, the server has captured
a machine check. When this LED is off, the server is not prepared to
capture a machine check.
Force BMC
update
1 2 (J57)
3 21
Physical
presence
(J70)
3 4
1 2
3
2 Boot recovery (J17)
1
24 IBM System x3850 M2 and System x3950 M2 Types 7141 and 7233: User’s Guide
I/O-board connectors
The following illustration shows the connectors on the I/O board.
Remote Supervisor Adapter II
Internal USB
ServeRAID-MR10k
SAS Hot-plug switch card
backplane
signal PCI Express x8
(x8 lanes) slot 1
PCI Express x8
Remote (x8 lanes) slot 2
Supervisor PCI Express x8
Adapter II (x8 lanes) slot 3
System
Management PCI Express x8
(x8 lanes) slot 4
access
PCI Express x8
Battery (x8 lanes) slot 5
PCI Express x8
Front USB (x8 lanes) slot 6
PCI Express x8
(x8 lanes) slot 7
SATA signal
SATA power
SAS backplane power
Front panel/light path diagnostics
DVD
If you are installing a hypervisor key, install it in the internal USB connector.
I/O-board LEDs
The following illustration shows the LEDs on the I/O board.
I/O card ServeRAID-MR10k
fault LED fault LED Power LED (2x)
RAID write
protect LED
SAS
heartbeat LED
Power-on
password
(J33)
1
2
3
1 1
2 Wake on LAN 2 Force power-on (J32)
3 bypass (J38) 3
26 IBM System x3850 M2 and System x3950 M2 Types 7141 and 7233: User’s Guide
SAS-backplane connectors
The following illustration shows the connectors on the SAS backplane.
Note: Changes are made periodically to the IBM Web site. The actual procedure
might vary slightly from what is described in this document.
1. Go to http://www.ibm.com/systems/support/.
2. Under Product support, click System x.
3. Under Popular links, click Software and device drivers.
4. Click IBM System x3850 M2 or IBM System x3950 M2 to display the matrix
of downloadable files for the server.
For additional information about tools for updating, managing, and deploying
firmware, see the System x and xSeries Tools Center at http://
publib.boulder.ibm.com/infocenter/toolsctr/v1r0/index.jsp.
v Before you install optional hardware devices, make sure that the server is
working correctly. Start the server, and make sure that the operating system
starts, if an operating system is installed, or that a 19990305 error code is
displayed, indicating that an operating system was not found but the server is
otherwise working correctly. If the server is not working correctly, see “Solving
Problems” in the Installation Guide for diagnostic information.
v Observe good housekeeping in the area where you are working. Place removed
covers and other parts in a safe place.
v If you must start the server while the cover is removed, make sure that no one is
near the server and that no tools or other objects have been left inside the
server.
v Do not attempt to lift an object that you think is too heavy for you. If you have to
lift a heavy object, observe the following precautions:
– Make sure that you can stand safely without slipping.
– Distribute the weight of the object equally between your feet.
– Use a slow lifting force. Never move suddenly or twist when you lift a heavy
object.
– To avoid straining the muscles in your back, lift by standing or by pushing up
with your leg muscles.
v Make sure that you have an adequate number of properly grounded electrical
outlets for the server, monitor, and other devices.
v Back up all important data before you make changes to disk drives.
v Have a small flat-blade screwdriver available.
v You do not have to turn off the server to install or replace hot-swap power
supplies, hot-swap fans, hot-plug adapters, or hot-plug Universal Serial Bus
(USB) devices. However, you must turn off the server before you perform any
steps that involve removing or installing adapter cables.
v Blue on a component indicates touch points, where you can grip the component
to remove it from or install it in the server, open or close a latch, and so on.
28 IBM System x3850 M2 and System x3950 M2 Types 7141 and 7233: User’s Guide
v Orange on a component or an orange label on or near a component indicates
that the component can be hot-swapped, which means that if the server and
operating system support hot-swap capability, you can remove or install the
component while the server is running. (Orange can also indicate touch points on
hot-swap components.) See the instructions for removing or installing a specific
hot-swap component for any additional procedures that you might have to
perform before you remove or install the component.
v When you are finished working on the server, reinstall all safety shields, guards,
labels, and ground wires.
v For a list of supported optional devices for the server, see http://www.ibm.com/
servers/eserver/serverproven/compat/us/.
The server supports hot-plug, hot-add, and hot-swap devices and is designed to
operate safely while it is turned on and the cover is removed. Follow these
guidelines when you work inside a server that is turned on:
30 IBM System x3850 M2 and System x3950 M2 Types 7141 and 7233: User’s Guide
Top cover
Cover release
latch
Bezel
4. Lift the cover-release latch. The cover slides to the rear approximately 13 mm
(0.5 inch). Lift the cover off the server.
Attention: For proper cooling and airflow, replace the top cover before you
turn on the server. Operating the server for more than 2 minutes with the top
cover removed might damage server components.
5. Press on the bezel retention tabs on the sides of the bezel, and pull the bezel
from the server.
Attention: Do not use the media hood handle to lift the server. Damage to the
server might result. Only use the lift handles on each side of the chassis to lift the
server.
Battery
cable
Cable Cable
guide guide
Battery
cable
connector
RAID
controller
1. Read the safety information that begins on page v and “Installation guidelines”
on page 28.
2. Turn off the server and peripheral devices, and disconnect the power cords
and all external cables as necessary to replace the device.
Attention: When you handle static-sensitive devices, take precautions to
avoid damage from static electricity. For details about handling these devices,
see “Handling static-sensitive devices” on page 30.
3. Remove the server cover (see “Removing the cover and bezel” on page 30).
4. Remove the divider that contains the battery holder from the server.
5. Open the retaining clip on each end of the connector.
6. Touch the static-protective package that contains the ServeRAID-MR10k SAS
controller to any unpainted metal surface on the outside of the server; then,
remove the controller from the package.
7. Turn the controller so that the keys align correctly with the slot.
8. Insert the controller into the connector by aligning the edges of the controller
with the slots at the ends of the connector.
Attention: Incomplete insertion might cause damage to the server or the
ServeRAID-MR10k SAS controller.
9. Firmly press the controller straight down into the connector by applying
pressure on both ends simultaneously. The retaining clips snap into the locked
position when the controller is seated in the connector.
10. Install the battery in the divider that contains the battery holder.
11. Connect the battery cable to the ServeRAID-MR10k SAS controller.
12. Install the divider that contains the battery holder in the server.
13. Route the battery cable through the cable routing guides on the divider to the
controller.
32 IBM System x3850 M2 and System x3950 M2 Types 7141 and 7233: User’s Guide
If you have other devices to install or remove, do so now. Otherwise, go to
“Completing the installation” on page 55.
Installing an adapter
The following notes describe the types of adapters that the server supports and
other information that you must consider when you install an adapter:
v Locate the documentation that comes with the adapter and follow those
instructions in addition to the instructions in this section. If you must change the
switch setting or jumper settings on the adapter, follow the instructions that come
with the adapter.
v See the documentation that comes with the operating system for information
about enabling a hot-plug PCI Express slot.
v Avoid touching the components and gold-edge connectors on the adapter.
v The server scans devices and PCI Express slots to assign system resources in
the following order: integrated Ethernet controller, integrated SAS controller, and
then PCI Express slots 1 through 7. If you have not changed the default startup
sequence, the server starts the devices in the following order: DVD drive,
USB-attached diskette drive, integrated SAS controller, PCI Express slots 1
through 7, and the integrated Ethernet controller.
Note: For hot-pluggable adapters, make sure that the PCI Express hot-plug device
driver is installed.
1. Read the safety information that begins on page v and “Installation guidelines”
on page 28.
2. If the adapter is not hot-pluggable, turn off the server and peripheral devices,
and disconnect the power cords and all external cables.
3. Remove the server cover (see “Removing the cover and bezel” on page 30)
and determine which PCI Express expansion slot you will use for the adapter.
PCI
divider
34 IBM System x3850 M2 and System x3950 M2 Types 7141 and 7233: User’s Guide
Retention pin
Adapter-retention
bracket
Removal button
Note: Press the removal button and pull up on the ratchet pin to remove the
ratchet pin from the adapter-retention bracket.
15. Connect any required cables to the adapter.
CAUTION:
The power control button on the device and the power switch on the power
supply do not turn off the electrical current supplied to the device. The device
also might have more than one power cord. To remove all electrical current
from the device, ensure that all power cords are disconnected from the power
source.
2
1
Release latch
Hot-swap
power supply
Release latch
Power supply
filler
36 IBM System x3850 M2 and System x3950 M2 Types 7141 and 7233: User’s Guide
v If the server will be configured for RAID operation, see the documentation that
comes with the controller for instructions for installing a hard disk drive.
v All hot-swap drives in the server should have the same throughput speed rating;
using drives with different speed ratings might cause all drives to operate at the
lowest throughput speed.
v To minimize the possibility of damage to the hard disk drives when you install the
server in a rack configuration, install the server in the rack before you install the
hard disk drives.
v You do not have to turn off the server to install hot-swap drives in the hot-swap
drive bays. However, you must turn off the server when you perform any steps
that involve installing or removing cables.
v Some filler panels come with slim fillers.
The following illustration shows how to install a hot-swap hard disk drive.
Filler panel
Drive-tray assembly
Drive handle
(in open position)
Note: When you turn on the server, check the hard disk drive status LEDs to make
sure that the hard disk drive is operating correctly. If the amber hard disk drive
status LED for a drive is lit continuously, that drive is faulty and must be replaced. If
the green hard disk drive activity LED is flashing, the drive is being accessed.
Retention latch
DVD drive
DVD filler
panel
38 IBM System x3850 M2 and System x3950 M2 Types 7141 and 7233: User’s Guide
Locking collar
1. Read the safety information that begins on page v and “Installation guidelines”
on page 28.
2. Remove the server cover (see “Removing the cover and bezel” on page 30).
3. Insert the drive into the connector.
4. Pull up on the locking collar to lock the drive in place.
Note: To remove an internal removable flash drive, push down on the connector to
unlock the drive before you remove the drive.
Memory module
The following notes describe the types of dual inline memory modules (DIMMs) that
the server supports and other information that you must consider when you install
DIMMs:
v The server supports 1.8 V, 240-pin, PC2-5300 double data-rate (DDR) II,
registered synchronous dynamic random-access memory (SDRAM) with error
correcting code (ECC) DIMMs. These DIMMs must be compatible with the latest
PC2-5300 SDRAM Registered DIMM specifications. For a list of the supported
optional devices for the server, see http://www.ibm.com/servers/eserver/
serverproven/compat/us/.
v The server supports up to four memory cards. Each memory card holds up to
eight DIMMs.
v At least one memory card with one pair of DIMMs must be installed for the
server to operate.
v When you install additional DIMMs on a memory card, be sure to install them in
pairs.
v You do not have to save new configuration information to the BIOS when you
install or remove DIMMs. The only exception is if you replace a DIMM that was
Memory card 1
Memory card 4
1 2 3 4
Memory card 3
Memory card 2
v The following illustration shows the DIMM connectors on the memory card.
DIMM 1
DIMM 2
DIMM 3
DIMM 4
DIMM 5
DIMM 6
DIMM 7
DIMM 8
v Install the DIMMs on each memory card in the order shown in the following
tables, depending on which memory configuration you want to use. You must
install at least one pair of DIMMs on each memory card.
Table 5. Low-cost memory-card installation sequence
DIMM pair installation
order Memory card Connector numbers
First 1 1 and 5
Second 2 1 and 5
Third 1 2 and 6
Fourth 2 2 and 6
40 IBM System x3850 M2 and System x3950 M2 Types 7141 and 7233: User’s Guide
Table 5. Low-cost memory-card installation sequence (continued)
DIMM pair installation
order Memory card Connector numbers
Fifth 1 3 and 7
Sixth 2 3 and 7
Seventh 1 4 and 8
Eighth 2 4 and 8
Ninth 3 1 and 5
Tenth 4 1 and 5
Eleventh 3 2 and 6
Twelfth 4 2 and 6
Thirteenth 3 3 and 7
Fourteenth 4 3 and 7
Fifteenth 3 4 and 8
Sixteenth 4 4 and 8
v There are four memory power buses, which are split among the four memory
cards.
v For memory mirroring, you must install DIMMs in sets of four, one pair in each
memory card. All DIMMs in each set must be the same size and type. Memory
cards 1 and 2 mirror each other, and memory cards 3 and 4 mirror each other.
v If a problem with a DIMM is detected, light path diagnostics will light the
system-error LED on the front of the server, indicating that there is a problem
and guiding you to the defective DIMM. When this occurs, first identify the
defective DIMM; then, remove and replace the DIMM.
The following illustration shows the LEDs that are visible on top of the memory
card.
42 IBM System x3850 M2 and System x3950 M2 Types 7141 and 7233: User’s Guide
Memory hot-swap
enabled LED
Memory card/DIMM
error LED
Memory card
power LED
Memory hot-swap enabled LED: When this LED is lit, it indicates that hot-swap
memory is enabled.
Memory card/DIMM error LED: When this LED is lit, it indicates that a memory
card or DIMM has failed.
Memory card power LED: When this LED is off, it indicates that power is
removed from the card and that you can remove the memory card and replace a
failed DIMM. This LED also turns off when the release levers are opened.
Active Memory
Active Memory is an IBM technology that improves the reliability of the DIMMs
through the memory mirroring, memory scrubbing, and Memory ProteXion™
features.
Note: For memory mirroring to work, DIMMs of the same size and clock speed
must be installed in both memory ports.
To enable memory mirroring, complete the following steps:
1. Install DIMMs of the same size and clock speed in the two memory ports.
2. Enable memory mirroring in the Configuration/Setup Utility program:
a. Turn on the server.
b. When the prompt Press F1 for Configuration/Setup is displayed, press
F1.
c. From the Configuration/Setup Utility main menu, select Advanced Setup.
d. Select Memory Settings.
Note: Memory scrubbing and Memory ProteXion technology work with each
other and do not require that memory mirroring be enabled.
When an error is detected, memory scrubbing determines whether the error is
recoverable. If it is recoverable, Memory ProteXion is enabled, and the data that
was stored in the damaged locations is rewritten to a new location. The event is
logged for informational purposes. Provided that there are enough good locations
to enable the correct operation of the server, no further action is taken other than
recording the event in the error logs.
If the error is not recoverable, memory scrubbing sends an error message to light
path diagnostics, which lights LEDs to guide you to the damaged DIMM. If
memory mirroring is enabled, the mirrored copy of the data in the mirrored DIMM
is used to refresh the new DIMM after it is installed.
v Memory ProteXion reassigns memory bits to new locations within memory when
recoverable errors have been detected.
When a recoverable error is found by memory scrubbing, the Memory ProteXion
feature writes the data that was to be stored in the damaged memory locations to
spare memory locations within the same DIMM.
44 IBM System x3850 M2 and System x3950 M2 Types 7141 and 7233: User’s Guide
c. Install DIMMs in the memory card (see “Installing DIMMs” on page 46).
5. Add the memory card.
Attention: When you move the memory card, do not allow it to touch any
components or structures inside the server.
a. Grasp the memory card by the retention levers and turn the memory card so
that the connector aligns with the connector on the microprocessor board
and the guides on the chassis.
b. Insert the memory card into the memory-card connector.
c. Press the memory card into the connector and close the retention levers.
d. Slide the orange release latch to the locked position.
Attention: When you move the memory card, do not allow it to touch any
components or structures inside the server.
5. Remove the memory card from the server:
a. Slide the orange release latch to the unlocked position.
Attention: To avoid loss of data, make sure that the memory port power
LED is off before you remove the memory card.
b. Make sure that the retention levers on the edge of the memory card are fully
open.
c. Lift the memory card out of the server.
6. Replace the memory card:
a. Grasp the new memory card by the retention levers and turn the memory
card so that the connector aligns with the connector on the microprocessor
board and the guides on the chassis.
Installing DIMMs
DIMMs must be installed in pairs of the same type and speed. For you to use the
memory mirroring feature, all the DIMMs that are installed in the server must be the
same type and speed, and the operating system must support memory mirroring.
The following instructions are for installing one pair of DIMMs. To install DIMM pairs
on more than one memory card, repeat steps 3 though 7 for each memory card.
Installing a DIMM
To install a DIMM, complete the following steps:
1. Read the safety information that begins on page v and “Installation guidelines”
on page 28.
2. If you are not hot-swapping a DIMM, turn off the server and peripheral devices,
and disconnect the power cords and all external cables as necessary to
replace the device.
3. Remove the server cover (see “Removing the cover and bezel” on page 30).
Attention: When you move the memory card, do not allow it to touch any
components or structures inside the server.
Release latch
46 IBM System x3850 M2 and System x3950 M2 Types 7141 and 7233: User’s Guide
Attention: To avoid loss of data, make sure that the memory port power
LED is off before you remove the memory card.
b. Open the retention levers on the top of the memory card.
c. While you hold the retention levers open, lift the memory card out of the
server.
5. Place a memory card on a flat, static-protective surface, with the DIMM
connectors facing up.
Attention: To avoid breaking the DIMM retaining clips or damaging the
DIMM connectors, open and close the clips gently.
6. Open the retaining clip on each end of the DIMM connector.
7. Touch the static-protective package that contains the DIMM to any unpainted
metal surface on the outside of the server. Then, remove the DIMM from the
package.
8. Turn the DIMM so that the DIMM keys align correctly with the slot.
9. Insert the DIMM into the connector by aligning the edges of the DIMM with the
slots at the ends of the DIMM connector. Firmly press the DIMM straight down
into the connector by applying pressure on both ends of the DIMM
simultaneously. The retaining clips snap into the locked position when the
DIMM is firmly seated in the connector.
Note: If there is a gap between the DIMM and the retaining clips, the DIMM
has not been correctly inserted; open the retaining clips, remove the DIMM,
and then reinsert it.
10. Replace the memory card:
a. Insert the memory card into the memory-card connector.
b. Press the memory card into the connector and close the retention levers.
c. Slide the orange release latch to the locked position.
Hot-swapping DIMMs
To hot-swap DIMMs, complete the following steps:
1. Read the safety information that begins on page v and “Installation guidelines”
on page 28.
Release latch
48 IBM System x3850 M2 and System x3950 M2 Types 7141 and 7233: User’s Guide
9. Insert the DIMM into the connector by aligning the edges of the DIMM with the
slots at the ends of the DIMM connector. Firmly press the DIMM straight down
into the connector by applying pressure on both ends of the DIMM
simultaneously. The retaining clips snap into the locked position when the
DIMM is firmly seated in the connector.
Note: If there is a gap between the DIMM and the retaining clips, the DIMM
has not been correctly inserted; open the retaining clips, remove the DIMM,
and then reinsert it.
10. Replace the memory card:
a. Insert the memory card into the memory-card connector.
b. Press the memory card into the connector and close the small retention
lever.
c. Wait 2 seconds and close the large retention lever.
d. Slide the orange release latch to the locked position.
Hot-adding DIMMs
The following notes describe information that you must consider when you hot-add
DIMMs and memory cards:
v The server must contain a minimum of 4 GB of memory.
v You must enable hot-add memory in the Configuration/Setup Utility program:
1. Turn on the server.
2. When the prompt Press F1 for Configuration/Setup is displayed, press F1.
3. From the Configuration/Setup Utility main menu, select Advanced Setup.
4. Select Memory Settings.
5. Enable the hot-add setting from within this window.
6. Save the settings and exit the Configuration/Setup Utility program.
v The operating system must support the hot-add feature.
v If a single memory card is installed in memory-card connector 1, you can hot-add
a memory card only in memory-card connector 2.
v If a single memory card is installed in memory-card connector 3, you can hot-add
a memory card only in memory-card connector 4.
v If two memory cards are installed in memory-card connectors 1 and 3, you can
hot-add two memory cards only in memory-card connectors 2 and 4.
Note: If there is a gap between the DIMM and the retaining clips, the DIMM
has not been correctly inserted; open the retaining clips, remove the DIMM,
and then reinsert it.
Release latch
8. Open the memory-card retention levers on the top of the memory card.
Attention: When you move the memory card, do not allow it to touch any
components or structures inside the server.
9. Insert the memory card into the memory-card connector.
10. Press the memory card into the connector and close the small retention lever.
11. Wait 2 seconds and close the large retention lever.
12. Slide the orange release latch to the locked position.
Installing a microprocessor
The following notes describe the type of microprocessor that the server supports
and other information that you must consider when you install a microprocessor:
50 IBM System x3850 M2 and System x3950 M2 Types 7141 and 7233: User’s Guide
v For a list of supported optional devices for the server, see http://www.ibm.com/
servers/eserver/serverproven/compat/us/.
v The server supports up to four Intel Xeon microprocessors. If you are installing
two or more microprocessors, they must be the same cache size and type, and
the same clock speed.
v The server can operate as a symmetric multiprocessing (SMP) server. With SMP,
certain operating systems and application programs can distribute the processing
load among the microprocessors. This enhances performance for database and
point-of-sale applications, integrated manufacturing solutions, and other
applications.
v The voltage regulators that come with the optional microprocessor must be
installed on the microprocessor board.
v Read the documentation that comes with the microprocessor to determine
whether you have to update the basic input/output system (BIOS) code. To
download the most current level of BIOS code for the server, complete the
following steps.
Note: Changes are made periodically to the IBM Web site. The actual procedure
might vary slightly from what is described in this document.
1. Go to http://www.ibm.com/systems/support/.
2. Under Product support, click System x.
3. Under Popular links, click Software and device drivers.
4. Click IBM System x3850 M2 or IBM System x3950 M2 to display the matrix
of downloadable files for the server.
v Obtain an SMP-capable operating system. For a list of supported operating
systems, see http://www.ibm.com/servers/eserver/serverproven/compat/us/.
v You can use the Configuration/Setup Utility program to determine the specific
type of microprocessor in the server.
v Populate the microprocessor sockets in numeric order, starting with socket 1. The
following illustration shows the locations of the microprocessor sockets and VRM
connectors on the microprocessor board.
VRM 3 VRM 4
connector connector
3 4
1 2
VRM 1 VRM 2
connector connector
V V
R R
CPU
CPU
M M
4
3
3 4
CPU CPU
1 2
Memory V V Memory
Cards R R Cards
M M
1 2 3 4
1 2
52 IBM System x3850 M2 and System x3950 M2 Types 7141 and 7233: User’s Guide
Captive
screws
5. If necessary, remove the microprocessor air baffle from between socket 1 and
socket 2.
6. If you are installing a microprocessor in microprocessor socket 2 and it
contains a heat-sink blank, remove the heat-sink blank and store it for future
use.
7. Remove the protective cover, tape, or label from the surface of the
microprocessor socket, if any is present.
Lever fully
open
Lever closed
Microprocessor
connector
Microprocessor-
release lever
Alignment posts
12. Remove the heat sink from its package and open the heat-sink retention clip:
a. Release the heat-sink retention clip from the locked position.
b. Rotate the heat-sink clip to its fully open position.
13. Remove the cover from the bottom of the heat sink.
14. Position the heat sink above the microprocessor and align the heat sink with
the alignment posts; then, press on the top of the heat sink, rotate the
heat-sink release lever, and move the lever to the locked position.
54 IBM System x3850 M2 and System x3950 M2 Types 7141 and 7233: User’s Guide
Alignment indicator
VRM cradle
Note: Make sure that the “Front” label on the VRM is facing the front of the
server.
16. Replace the microprocessor air baffle between socket 1 and socket 2, if you
removed it.
17. Rotate the media hood to the closed position and tighten the captive screws.
1. Make sure that all internal cables are correctly routed. In the order listed, route
the following cables through the cable channel; then, connect the cables to the
I/O board.
a. SAS power cable
b. SAS 4x signal cable
c. Operator information panel cable
Top cover
Cover release
latch
Bezel
3. Install the server in a rack. See the Rack Installation Instructions that come with
the server for complete rack installation and removal instructions.
Attention:
v Install the server only in a rack cabinet that has perforated doors.
v Do not leave open spaces above or below an installed server in the rack
cabinet. To help prevent damage to server components, always install filler
panels to cover open spaces and to help ensure proper air circulation. See
the documentation that comes with your rack cabinet for more information.
4. Connect the cables and power cords. For more information, see “Connecting
the cables.”
5. Update the server configuration. See “Updating the server configuration” on
page 57.
Cable identifiers are printed on the cables that come with the server and optional
devices. Use these identifiers to connect the cables to the correct connectors.
For details about the locations and functions of the input and output connectors,
see “Server controls, connectors, LEDs, and power” on page 11.
When available, you can install one or more optional SMP Expansion kits to
interconnect the SMP Expansion Ports of two or more servers.
The following illustrations show the locations of the input and output connectors on
the server. Detailed cabling instructions are in the Rack Installation Instructions that
come with the server.
56 IBM System x3850 M2 and System x3950 M2 Types 7141 and 7233: User’s Guide
Rear view
Remote Supervisor Adapter II
SAS USB
System serial Power-supply 1
Front view
Power-control button/power-on LED Information LED
Ethernet icon LED System-error LED
1 2
Power-control button cover Ethernet port activity LEDs Locator button/locator LED
Some optional devices have device drivers that you must install. For information
about installing device drivers, see the documentation that comes with each device.
The server can operate as a symmetric multiprocessing (SMP) server. You might
have to upgrade the operating system to support SMP. For more information, see
“Using the ServerGuide Setup and Installation CD” on page 68 and the
operating-system documentation.
If the server has a RAID configuration that uses an optional RAID controller and
you have installed or removed a hard disk drive, see the documentation that comes
with the RAID controller for information about reconfiguring the disk arrays.
If the server has a RAID configuration that uses the integrated SAS controller with
RAID capabilities and you have installed or removed a hard disk drive, you might
have to reconfigure the disk arrays.
For information about configuring the integrated Gigabit Ethernet controller, see
“Configuring the Gigabit Ethernet controller” on page 70.
Chapter 2. Installing optional devices 57
58 IBM System x3850 M2 and System x3950 M2 Types 7141 and 7233: User’s Guide
Chapter 3. Configuring the server
The following configuration programs come with the server:
v Configuration/Setup Utility program
The Configuration/Setup Utility program is part of the basic input/output system
(BIOS). Use it to configure serial port assignments and scalable partitions,
change interrupt request (IRQ) settings, change the startup-device sequence, set
the date and time, and set passwords. For information about using this program,
see “Using the Configuration/Setup Utility program” on page 60.
v IBM ServerGuide Setup and Installation CD
The ServerGuide program provides software-setup tools and installation tools
that are designed for the server. Use this CD during the installation of the server
to configure basic hardware features, such as an integrated SAS controller with
RAID capabilities, and to simply the installation of your operating system. For
information about using this CD, see “Using the ServerGuide Setup and
Installation CD” on page 68.
v Boot Menu program
The Boot Menu program is part of the BIOS. Use it to override the startup
sequence that is set in the Configuration/Setup Utility program and temporarily
assign a device to be first in the startup sequence. For information about using
this program, see “Using the Boot Menu program” on page 70.
v Ethernet controller configuration
For information about configuring the Ethernet controller, see “Configuring the
Gigabit Ethernet controller” on page 70.
v Baseboard management controller utility programs
Use these programs to configure the baseboard management controller, to apply
updates to the firmware, and to remotely manage a server. For information about
using these programs, see “Using the baseboard management controller utility
programs” on page 70.
v Remote Supervisor Adapter II configuration
For information about setting up and cabling the Remote Supervisor Adapter II,
see the Remote Supervisor Adapter II SlimLine and Remote Supervisor Adapter
II User’s Guide on the IBM System x Documentation CD.
v IBM Electronic Service Agent
IBM Electronic Service Agent is a software tool that monitors the server for
hardware error events and automatically submits electronic service requests to
the IBM Support Center. Also, it can collect and transmit system configuration
information on a scheduled basis so that the information is available to you and
your support representative. It uses minimal system resources, is available free
of charge, and can be downloaded from the Web. For more information and to
download Electronic Service Agent, go to http://www.ibm.com/support/electronic/.
v RAID configuration programs
– LSI Logic Configuration Utility program
Use the LSI Logic Configuration Utility program to perform the initial
configuration on the disk-array subsystem that is connected to the integrated
SAS controller with RAID capabilities and, optionally, the ServeRAID-MR10k
controller. For information about using this program, see “Using the LSI Logic
Configuration Utility program” on page 74.
– LSI Logic MegaRAID Storage Manager program
60 IBM System x3850 M2 and System x3950 M2 Types 7141 and 7233: User’s Guide
stored in electrically erasable programmable ROM (EEPROM), and the
revision level of the firmware on the Remote Supervisor Adapter II.
– System Card Data
Select this choice to view vital product data (VPD) for some server
components.
v Devices and I/O Ports
Select this choice to view or change assignments for devices and input/output
(I/O) ports.
Select this choice to enable or disable integrated SAS and Ethernet controllers
and all standard ports (such as serial and parallel). Enable is the default setting
for all controllers. If you disable a device, it cannot be configured, and the
operating system will not be able to detect it (this is equivalent to disconnecting
the device). If you disable the integrated Ethernet controller and no Ethernet
adapter is installed, the server will have no Ethernet capability.
This choice is on the full Configuration/Setup Utility menu only.
v Date and Time
Select this choice to set the date and time in the server, in 24-hour format
(hour:minute:second).
This choice is on the full Configuration/Setup Utility menu only.
v System Security
Select this choice to set passwords. See “Passwords” on page 66 for more
information about passwords. You can also enable the chassis-intrusion detector
to alert you each time the server cover is removed.
This choice is on the full Configuration/Setup Utility menu only.
– Power-on Password
Select this choice to set or change a power-on password. For more
information, see “Power-on password” on page 66.
– Administrator Password
Attention: If you set an administrator password and then forget it, there is
no way to change, override, or remove it. You must replace the
microprocessor board.
Select this choice to set or change an administrator password. An
administrator password is intended to be used by a system administrator; it
limits access to the full Configuration/Setup Utility menu. If an administrator
password is set, the full Configuration/Setup Utility menu is available only if
you type the administrator password at the password prompt. See
“Administrator password” on page 67 for more information.
v Start Options
Select this choice to view or change the start options. Changes in the start
options take effect when you restart the server.
You can set keyboard operating characteristics, such as the keyboard speed, and
you can specify whether the server starts with the keyboard number lock on or
off.
The startup sequence specifies the order in which the server checks devices to
find a boot record. The server starts from the first boot record that it finds. If the
server has Wake on LAN hardware and software and the operating system
supports Wake on LAN functions, you can specify a startup sequence for the
Wake on LAN functions.
If you enable the boot fail count, the BIOS default settings will be restored after
three consecutive failures to find a boot record.
62 IBM System x3850 M2 and System x3950 M2 Types 7141 and 7233: User’s Guide
Select this choice enable or disable the execute disable bit feature. Enable
is the default value.
- Intel Virtualization Technology
Select this choice to enable or disable the Intel virtualization technology.
Select Enable to make available the additional hardware capabilities of
virtual machine extensions. Enable is the default value.
- Processor IP Prefetcher
Select this choice to enable or disable the IP prefetcher. Enable is the
default value.
- Processor DCU Prefetcher
Select this choice to enable or disable the DCU prefetcher. Enable is the
default value.
- C1E
Select this choice to enable or disable the C1E feature. The C1E feature
reduces microprocessor power consumption. Enable is the default value.
– TPM Menu
Select this choice to set the trusted platform module (TPM) feature. For more
information, see http://www.ibm.com/systems/support/supportsite.wss/
docdisplay?lndocid=MIGR-5072502&brandind=5000008.
– Partition Chassis Options
Select this choice to set the partition configuration options for use in a
multi-node configuration.
– Advanced PCI Settings
Select this choice to view and set the end-to-end cyclic redundancy check
(ECRC) of individual PCI Express slots. ECRC is a data transmission error
detection feature. You can also enable or disable the ROM execution of
individual PCI Express slots.
– PCI Slot/Device Information
Select this choice to view system resources that are used by installed PCI
Express devices. PCI Express devices are usually configured automatically.
This information is saved when you exit. The Save Settings, Restore
Settings, and Load Default Settings choices on the Configuration/Setup
Utility main menu do not save the PCI Slot/Device Information settings.
– RSA II Settings
Select this choice to view and change Remote Supervisor Adapter II settings.
Select Save Values and Reboot RSA II to save the changes that you have
made in the settings and restart the Remote Supervisor Adapter II.
- RSA II MAC Address
This is a nonselectable menu item that displays the Remote Supervisor
Adapter II MAC address.
- DHCP IP Address
This is a nonselectable menu item that displays the Remote Supervisor
Adapter II DHCP IP address, if DHCP is enabled.
- DHCP Control
Select this choice to set the DHCP control. DHCP Enabled is the default. If
you select Use Static IP, use Static IP Address to set the address.
- Static IP Address
Select this choice to set the static IP address for the Remote Supervisor
Adapter II.
64 IBM System x3850 M2 and System x3950 M2 Types 7141 and 7233: User’s Guide
Select this choice to set the DHCP control. DHCP Enabled is the default
setting. If you select Use Static IP, use IP Address to set the address.
v IP Address
Select this choice to set the static IP address for the BMC. The initial
value is assigned by the DHCP server or is 169.254.0.2.
v Subnet Mask
Select this choice to set the subnet mask for the BMC. The default is
255.255.0.0.
v Gateway
Select this choice to set the gateway for the BMC. The default is 0.0.0.0.
v Save Network Settings in BMC
Select this choice to save any changes to the network configuration.
- BMC System Event Log
Select this choice to view the BMC system event log, which contains all
system-error and warning messages that have been generated. Use the
arrow keys to move among pages in the log. See the Problem
Determination and Service Guide on the IBM System x Documentation CD
for instructions. Select Clear error logs to clear the BMC system event log.
Note: Use the IBM Remote Supervisor Adapter II system event log or run
the diagnostic programs for more information about the error codes.
- User Account Settings
Select this choice to view and change the BMC user account information.
You can define up to four user accounts. By default, two user accounts are
defined: NULL and USERID. The USERID user account is enabled by
default. The password for the USERID user account is PASSW0RD.
- UserID
Select this choice to view or change settings for user accounts 1, 2, 3, and
4.
v UserID
Select this choice to enable or disable the user account. The NULL user
account is disabled by default.
v Username
Select this choice to view or change the user name.
v Password
Select this choice to set the password.
v Confirm Password
Select this choice to confirm the password.
v Privilege Limit
Select this choice to set the level of access.
v Save User Account Settings in BMC
Select this choice to save any changes to the user account configuration.
v Event/Error Logs
Select this choice to view or clear error logs.
This choice is available on the full Configuration/Setup Utility menu only.
– POST Error Log
Passwords
From the System Security choice, you can set, change, and delete a power-on
password and an administrator password. The System Security choice is on the
full Configuration/Setup Utility menu only.
If you set only a power-on password, you must type the power-on password to
complete the system startup, and you have access to the full Configuration/Setup
Utility menu.
If you set a power-on password for a user and an administrator password for a
system administrator, you can type either password to complete the system startup.
A system administrator who types the administrator password has access to the full
Configuration/Setup Utility menu; the system administrator can give the user
authority to set, change, and delete the power-on password. A user who types the
power-on password has access to only the limited Configuration/Setup Utility menu;
the user can set, change, and delete the power-on password, if the system
administrator has given the user that authority.
Power-on password
If a power-on password is set, when you turn on the server, you must type the
power-on password to complete the system startup. You can use any combination
of up to seven characters (A - Z, a - z, and 0 - 9) for the password.
If a power-on password is set, you can enable the Unattended Start mode, in which
the keyboard and mouse remain locked but the operating system can start. You can
unlock the keyboard and mouse by typing the power-on password.
66 IBM System x3850 M2 and System x3950 M2 Types 7141 and 7233: User’s Guide
If you forget the power-on password, you can regain access to the server in any of
the following ways:
v If an administrator password is set, type the administrator password at the
password prompt. Start the Configuration/Setup Utility program and reset the
power-on password.
v Remove the battery from the server and then reinstall it. For instructions for
removing the battery, see ″Replacing the battery″ in the Problem Determination
and Service Guide.
v Change the position of the power-on password override jumper (J33 on the I/O
board) to bypass the power-on password check.
Attention: Before changing any switch settings or moving any jumpers, turn off
the server; then, disconnect all power cords and external cables. See the safety
information that begins on page v. Do not change settings or move jumpers on
any system-board switch or jumper blocks that are not shown in this document.
The following illustration shows the location of the power-on password override,
force power-on, and Wake on LAN (WOL) bypass jumpers.
Power-on
password
(J33)
1
2
3
1 1
2 Wake on LAN 2 Force power-on (J32)
3 bypass (J38) 3
While the server is turned off, move the jumper on J9 from pins 1 and 2 to pins 2
and 3. You can then start the Configuration/Setup Utility program and reset the
power-on password. After you reset the password, turn off the server again and
move the jumper back to pins 1 and 2.
The power-on password override switch does not affect the administrator
password.
Administrator password
If an administrator password is set, you must type the administrator password for
access to the full Configuration/Setup Utility menu. You can use any combination of
up to seven characters (A - Z, a - z, and 0 - 9) for the password.
Attention: If you set an administrator password and then forget it, there is no way
to change, override, or remove it. You must replace the microprocessor board.
If a later version of the ServerGuide program is available, you can download a free
image of the ServerGuide Setup and Installation CD, or you can purchase the CD.
To download the image, go to the IBM ServerGuide Web page at
http://www.ibm.com/pc/qtechinfo/MIGR-4ZKPPT.html. To purchase the latest
ServerGuide Setup and Installation CD, go to the ServerGuide fulfillment Web site
at http://www.ibm.com/systems/management/serverguide/sub.html.
ServerGuide features
Features and functions can vary slightly with different versions of the ServerGuide
program. To learn more about the version that you have, start the ServerGuide
Setup and Installation CD and view the online overview. Not all features are
supported on all server models.
68 IBM System x3850 M2 and System x3950 M2 Types 7141 and 7233: User’s Guide
Note: Features and functions can vary slightly with different versions of the
ServerGuide program.
When you start the ServerGuide Setup and Installation CD, the program prompts
you to complete the following tasks:
v Select your language.
v Select your keyboard layout and country.
v View the overview to learn about ServerGuide features.
v View the readme file to review installation tips for your operating system and
adapter.
v Start the operating-system installation. You will need your operating-system CD.
Note: Features and functions can vary slightly with different versions of the
ServerGuide program.
1. After you have completed the setup process, the operating-system installation
program starts. (You will need your operating-system CD to complete the
installation.)
2. The ServerGuide program stores information about the server model, service
processor, hard disk drive controllers, and network adapters. Then, the program
checks the CD for newer device drivers. This information is stored and then
passed to the operating-system installation program.
3. The ServerGuide program presents operating-system partition options that are
based on your operating-system selection and the installed hard disk drives.
4. The ServerGuide program prompts you to insert your operating-system CD and
restart the server. At this point, the installation program for the operating system
takes control to complete the installation.
Note: Changes are made periodically to the IBM Web site. The actual procedure
might vary slightly from what is described in this document.
1. Go to http://www.ibm.com/systems/support/.
2. Under Product support, click System x.
3. From the menu on the left side of the page, click System x support search.
4. From the Task menu, select Install.
5. From the Product family menu, select IBM System x3850 M2 or IBM System
x3950 M2.
6. From the Operating system menu, select your operating system, and then click
Search to display the available installation documents.
The next time the server is started, it returns to the startup sequence that is set in
the Configuration/Setup Utility program.
You do not have to set any jumpers or configure the controller. However, you must
install a device driver to enable the operating system to address the controller. For
device drivers and information about configuring the Ethernet controller, see the
Broadcom NetXtreme Gigabit Ethernet Software CD that comes with the server. To
find updated information about configuring the controller, complete the following
steps.
Note: Changes are made periodically to the IBM Web site. The actual procedure
might vary slightly from what is described in this document.
1. Go to http://www.ibm.com/systems/support/.
2. Under Product support, click System x.
3. Under Popular links, click Publications lookup.
4. From the Product family menu, select System x3850 M2 or System x3950 M2
and click Continue.
70 IBM System x3850 M2 and System x3950 M2 Types 7141 and 7233: User’s Guide
To download the program, complete the following steps.
Note: Changes are made periodically to the IBM Web site. The actual procedure
might vary slightly from what is described in this document.
1. Go to http://www.ibm.com/systems/support/.
2. Under Product support, click System x.
3. Under Popular links, click Software and device drivers.
4. Click IBM System x3850 M2 or IBM System x3950 M2 to display the matrix of
downloadable files for the server.
5. From the BMC software section, download the file for the operating system and
for the DOS firmware update utility from which you will perform the configuration
and create a firmware update diskette or CD.
Note: Changes are made periodically to the IBM Web site. The actual procedure
might vary slightly from what is described in this document.
1. Go to http://www.ibm.com/systems/support/.
2. Under Product support, click System x.
3. Under Popular links, click Software and device drivers.
4. Click IBM System x3850 M2 or IBM System x3950 M2 to display the matrix of
downloadable files for the server.
5. From the BMC software section, download the file for the operating system and
the media (diskette or CD) that you plan to use.
Attention: Before changing any switch settings or moving any jumpers, turn off
the server; then, disconnect all power cords and external cables. See the safety
information beginning on page v. Do not change settings or move jumpers on any
system-board switch or jumper blocks that are not shown in this document.
The following illustration shows the location of the force BMC update, and boot
recovery jumpers.
Force BMC
update
1 2 (J57)
3 21
Physical
presence
(J70)
3 4
1 2
3
2 Boot recovery (J17)
1
While the server is turned off, place a jumper over pins 1 and 2 on J57. Then,
perform a firmware update. Turn off the server again and remove the jumper from
pins 1 and 2.
Note: Only use the force BMC update jumper if the normal firmware update
procedure fails and the operational firmware image is corrupted. Use of the force
BMC update jumper disables normal baseboard management controller operation.
72 IBM System x3850 M2 and System x3950 M2 Types 7141 and 7233: User’s Guide
Using the management utility program
Use the baseboard management controller management utility program to remotely
manage and configure a server. The following features are available from the
program:
v IPMI (Intelligent Platform Management Interface) Shell
Use this feature to remotely perform power-management and system
identification control functions over a LAN or serial port interface from a
command-line interface. Use this feature also to remotely view the event log.
v Serial over LAN Proxy
Use this feature to remotely perform control and management functions over a
Serial over LAN network. Use this feature also to remotely view and change the
BIOS settings.
To download the utility program and create the baseboard management controller
management utility CD, complete the following steps.
Note: Changes are made periodically to the IBM Web site. The actual procedure
might vary slightly from what is described in this document.
1. Go to http://www.ibm.com/systems/support/.
2. Under Product support, click System x.
3. Under Popular links, click Software and device drivers.
4. Click IBM System x3850 M2 or IBM System x3950 M2 to display the matrix of
downloadable files for the server.
5. From the BMC software section, download the management utility
(SMBRIDGE).
6. Review the readme file on the CD to install and use the program.
Note: The bezel identifies the SCSI IDs of the hard disk drive bays.
74 IBM System x3850 M2 and System x3950 M2 Types 7141 and 7233: User’s Guide
Using the LSI Logic MegaRAID Storage Manager program
Use the LSI Logic MegaRAID Storage Manager program to monitor and manage
the disk-array subsystem connected to the integrated SAS controller with RAID
capabilities and the ServeRAID-MR10k controller option. The LSI Logic MegaRAID
Storage Manager program, device drivers, and information come with the
ServeRAID-MR10k controller option.
To install the IBM Director updates and any other applicable updates and interim
fixes, complete the following steps:
1. Check for the latest version of IBM Director:
a. Go to http://www.ibm.com/systems/management/director/downloads.html.
b. If a newer version of IBM Director than what comes with the server is shown
in the drop-down list, follow the instructions on the Web page to download
the latest version.
2. Install the IBM Director program.
3. Download and install any applicable updates or interim fixes for the server:
a. Go to http://www.ibm.com/systems/support/.
b. Under Product support, click System x.
c. Under Popular links, click Software and device drivers.
d. Click IBM Director downloads.
e. Select any applicable update or interim fix that you want to download.
f. Click the file link for the executable file to download the file, and follow the
instructions in the readme file to install the update or interim fix.
g. Repeat steps 3e and 3f for any additional updates or interim fixes that you
want to install.
IBM may not offer the products, services, or features discussed in this document in
other countries. Consult your local IBM representative for information on the
products and services currently available in your area. Any reference to an IBM
product, program, or service is not intended to state or imply that only that IBM
product, program, or service may be used. Any functionally equivalent product,
program, or service that does not infringe any IBM intellectual property right may be
used instead. However, it is the user’s responsibility to evaluate and verify the
operation of any non-IBM product, program, or service.
IBM may have patents or pending patent applications covering subject matter
described in this document. The furnishing of this document does not give you any
license to these patents. You can send license inquiries, in writing, to:
IBM Director of Licensing
IBM Corporation
North Castle Drive
Armonk, NY 10504-1785
U.S.A.
Any references in this information to non-IBM Web sites are provided for
convenience only and do not in any manner serve as an endorsement of those
Web sites. The materials at those Web sites are not part of the materials for this
IBM product, and use of those Web sites is at your own risk.
IBM may use or distribute any of the information you supply in any way it believes
appropriate without incurring any obligation to you.
Trademarks
IBM, the IBM logo, and ibm.com are trademarks or registered trademarks of
International Business Machines Corporation in the United States, other countries,
or both. If these and other IBM trademarked terms are marked on their first
occurrence in this information with a trademark symbol (® or ™), these symbols
indicate U.S. registered or common law trademarks owned by IBM at the time this
information was published. Such trademarks may also be registered or common law
trademarks in other countries. A current list of IBM trademarks is available on the
Web at “Copyright and trademark information” at http://www.ibm.com/legal/
copytrade.shtml.
© Copyright IBM Corp. 2009 79
Adobe and PostScript are either registered trademarks or trademarks of Adobe
Systems Incorporated in the United States and/or other countries.
Intel, Intel Xeon, Itanium, and Pentium are trademarks or registered trademarks of
Intel Corporation or its subsidiaries in the United States and other countries.
Java and all Java-based trademarks are trademarks of Sun Microsystems, Inc., in
the United States, other countries, or both.
UNIX is a registered trademark of The Open Group in the United States and other
countries.
Important notes
Processor speed indicates the internal clock speed of the microprocessor; other
factors also affect application performance.
CD or DVD drive speed is the variable read rate. Actual speeds vary and are often
less than the possible maximum.
When referring to processor storage, real and virtual storage, or channel volume,
KB stands for 1024 bytes, MB stands for 1 048 576 bytes, and GB stands for
1 073 741 824 bytes.
Maximum internal hard disk drive capacities assume the replacement of any
standard hard disk drives and population of all hard disk drive bays with the largest
currently supported drives that are available from IBM.
80 IBM System x3850 M2 and System x3950 M2 Types 7141 and 7233: User’s Guide
Some software might differ from its retail version (if available) and might not include
user manuals or all program functionality.
Particulate contamination
Attention: Airborne particulates (including metal flakes or particles) and reactive
gases acting alone or in combination with other environmental factors such as
humidity or temperature might pose a risk to the server that is described in this
document. Risks that are posed by the presence of excessive particulate levels or
concentrations of harmful gases include damage that might cause the server to
malfunction or cease functioning altogether. This specification sets forth limits for
particulates and gases that are intended to avoid such damage. The limits must not
be viewed or used as definitive limits, because numerous other factors, such as
temperature or moisture content of the air, can influence the impact of particulates
or environmental corrosives and gaseous contaminant transfer. In the absence of
specific limits that are set forth in this document, you must implement practices that
maintain particulate and gas levels that are consistent with the protection of human
health and safety. If IBM determines that the levels of particulates or gases in your
environment have caused damage to the server, IBM may condition provision of
repair or replacement of servers or parts on implementation of appropriate remedial
measures to mitigate such environmental contamination. Implementation of such
remedial measures is a customer responsibility.
Table 8. Limits for particulates and gases
Contaminant Limits
Particulate v The room air must be continuously filtered with 40% atmospheric dust
spot efficiency (MERV 9) according to ASHRAE Standard 52.21.
v Air that enters a data center must be filtered to 99.97% efficiency or
greater, using high-efficiency particulate air (HEPA) filters that meet
MIL-STD-282.
v The deliquescent relative humidity of the particulate contamination
must be more than 60%2.
v The room must be free of conductive contamination such as zinc
whiskers.
Gaseous v Copper: Class G1 as per ANSI/ISA 71.04-19853
v Silver: Corrosion rate of less than 300 Å in 30 days
1
ASHRAE 52.2-2008 - Method of Testing General Ventilation Air-Cleaning Devices for
Removal Efficiency by Particle Size. Atlanta: American Society of Heating, Refrigerating and
Air-Conditioning Engineers, Inc.
2
The deliquescent relative humidity of particulate contamination is the relative humidity at
which the dust absorbs enough water to become wet and promote ionic conduction.
3
ANSI/ISA-71.04-1985. Environmental conditions for process measurement and control
systems: Airborne contaminants. Instrument Society of America, Research Triangle Park,
North Carolina, U.S.A.
Documentation format
The publications for this product are in Adobe Portable Document Format (PDF)
and should be compliant with accessibility standards. If you experience difficulties
when you use the PDF files and want to request a Web-based format or accessible
PDF document for a publication, direct your mail to the following address:
Information Development
IBM Corporation
205/A015
Appendix. Notices 81
3039 E. Cornwallis Road
P.O. Box 12195
Research Triangle Park, North Carolina 27709-2195
U.S.A.
In the request, be sure to include the publication part number and title.
When you send information to IBM, you grant IBM a nonexclusive right to use or
distribute the information in any way it believes appropriate without incurring any
obligation to you.
Properly shielded and grounded cables and connectors must be used in order to
meet FCC emission limits. IBM is not responsible for any radio or television
interference caused by using other than recommended cables and connectors or by
unauthorized changes or modifications to this equipment. Unauthorized changes or
modifications could void the user’s authority to operate the equipment.
This device complies with Part 15 of the FCC Rules. Operation is subject to the
following two conditions: (1) this device may not cause harmful interference, and (2)
this device must accept any interference received, including interference that may
cause undesired operation.
82 IBM System x3850 M2 and System x3950 M2 Types 7141 and 7233: User’s Guide
European Union EMC Directive conformance statement
This product is in conformity with the protection requirements of EU Council
Directive 2004/108/EC on the approximation of the laws of the Member States
relating to electromagnetic compatibility. IBM cannot accept responsibility for any
failure to satisfy the protection requirements resulting from a nonrecommended
modification of the product, including the fitting of non-IBM option cards.
This product has been tested and found to comply with the limits for Class A
Information Technology Equipment according to CISPR 22/European Standard EN
55022. The limits for Class A equipment were derived for commercial and industrial
environments to provide reasonable protection against interference with licensed
communication equipment.
Appendix. Notices 83
IBM verändert bzw. wenn Erweiterungskomponenten von Fremdherstellern ohne
Empfehlung der IBM gesteckt/eingebaut werden.
Generelle Informationen:
84 IBM System x3850 M2 and System x3950 M2 Types 7141 and 7233: User’s Guide
Index
A cover, removing 30
accessible documentation 81
Active
Memory 6, 43
D
PCI Express 33 danger statements 2
adapter device drivers 10
hot-plug 33 dimensions 5
installing 33 documentation format 81
ServeRAID-MR10k 31 drives 5
PCI 33 DVD drive
PCI Express 33 install 38
ServeRAID-MR10k 31 DVD-eject button 11
adding memory card 44 DVD-ROM
administrator password 67 activity LED 11
attention notices 2 eject button 11
Automatic BIOS recovery 8
availability 8
E
electrical input 5
B electronic emission Class A notice 82
baseboard management controller 6 electrostatic-discharge connector 12
bays 5 Enterprise X-Architecture technology 6
bezel removing 30 environment 5
error LED
memory 21, 43
C memory card 21, 43
microprocessor 23
cable
microprocessor board 22, 23
external cabling 56
system 12, 13
routing 56
VRM 23
cabling the server 56
Ethernet 8
cache 5
activity LED 12, 14
caution statements 2
configuring 59
Class A electronic emission notice 82
Gigabit activity LED 12, 14
components, server 19
Gigabit configuring 59
configuration
Gigabit connector 13
baseboard management controller utility
Gigabit controller 7
programs 59
Gigabit link LED 13
boot menu program 59
expansion bays 5
Gigabit Ethernet controller 59
expansion slots 5
SAS/SCSI device 57
external cabling 56
ServerGuide Setup and Installation CD 59
with ServerGuide 68
Configuration/Setup Utility program 59, 60
connector
F
electrostatic-discharge 12 fans 8
external SAS 15 FCC Class A notice 82
Gigabit Ethernet 13 features
power-supply 14, 15 ServerGuide 68
Remote Supervisor Adapter II 14 specifications 4
system serial 15 filler panel, hard disk drive bay 37
USB, front 11 front USB connector 11
USB, rear 15
connectors
memory card 21 G
microprocessor-board 22 gaseous contamination 5, 81
contamination, particulate and gaseous 5, 81 Gigabit Ethernet
cooling 8 activity LED 13
86 IBM System x3850 M2 and System x3950 M2 Types 7141 and 7233: User’s Guide
N ServerGuide
features 68
noise emissions 5
NOS installation 69
NOS installation
Setup and Installation CD 6, 59
with ServerGuide 69
using 68
without ServerGuide 69
serviceability 8
notes 2
setup
notes, important 80
with ServerGuide 68
notices 79
size 5
electronic emission 82
slots 5
FCC, Class A 82
SMP
notices and statements 2
description 8
expansion port link LEDs 15
SMP Expansion Port connectors
O expansion port connectors 15
online publications 2 specifications 4
operator information panel 11 statements and notices 2
symmetric multiprocessing 8
system reliability guidelines 29
P system-error LED 12, 13
particulate contamination 5, 81 systems management 8, 9
password
administrator 67
power-on 66 T
power-on override jumper 67, 72 table
passwords 66 features and specifications 4
power I/O board jumpers 23, 24
features 15 I/O-board jumpers 26
requirement 5 memory
power supply cost-sensitive configuration 41
connector 14, 15 memory-mirroring configuration 41
specification 5 performance configuration 40
power-control temperature 5
button 12 trademarks 79
button cover 12 turning off the server 16
power-on turning on the server 15
LED 12, 13
password 66
publications 1 U
United States electronic emission Class A notice 82
United States FCC Class A notice 82
R UpdateXpress 10
rack, installing your server in 56 USB connectors 11, 15
RAS features 8 utility
rear baseboard management controller utility
USB connectors 15 programs 70
view 13 Configuration/Setup program 60
redundant cooling and power 8 LSI Logic Configuration Utility program 73
reliability 8 LSI Logic MegaRAID Storage Manager program 73
Remote Supervisor Adapter II connectors 14 ServerGuide 68
removing the boot menu program 70
bezel 30
cover 30
W
Web site
S ServerGuide 68
SAS connector 15 utility program 73
scalability LED 12 weight 5
serial connector 15 working inside the server with the power on 29
ServeRAID 8
Index 87
X
X-Architecture technology 6
88 IBM System x3850 M2 and System x3950 M2 Types 7141 and 7233: User’s Guide
Printed in USA