Flammability Test Report: 575 Maryville Centre Drive

Download as pdf or txt
Download as pdf or txt
You are on page 1of 2

FLAMMABILITY TEST REPORT

Report No.: LEHTX00880653 Date Received: 25/01/18 Date Tested: 07/02/18 Date Issued: 01/03/18

Company Name & Address: EASTMAN PERFORMANCE FILMS, LLC


575 MARYVILLE CENTRE DRIVE
ST. LOUIS MO 63141-5713
USA
Contact Name:
N/A

Sample Details Reference


No.: Not stated
Order No.: Not stated
Style No.: Not stated
Batch No.: Not stated
Quality: Not stated
Colour: Not stated
Supplier: Not stated
Intended Use: Not stated
Quoted Fibre Composition: Not stated
Retailer: Not stated
Buying Division: Not stated
Sample Description: 6mm glass with 20 µm polyester installed.

Flammability Performance Requirement


Test Method Pre Treatment Result

Burn rate no greater than 4 inches per


FMVSS 302: 2011 None minute (102mm/min) as specified in BS PASS
AU 169a:1992 ISO 3795 1989

…………………………….. ………………………… …………………………. ……………………………..


STEVEN OWEN ANDREW HALLETT CAROLE SPOWART SIMON CHEE
(Chemical Technologist) (Flammability Team Leader) (Flammability Technician) (Operations Manager)

Report No.: LEHTX00900653 Page 1 of 2


FLAMMABILITY TEST REPORT
Test Specification
Test Method: FMVSS 302: 2011
Pretreatment: None
Conditioning: Prior to testing for a minimum of 24 hours at 50±5% RH & 21±2°C

Test Results
Length Of Flame Burn Time From
First Marker Burning Rate B
Specimen Number Travel From First First Marker T
Reached (mm/min)
Marker D (mm) (Seconds)
1 No 0.0 0.0 0.0
2 No 0.0 0.0 0.0
3 No 0.0 0.0 0.0
4 No 0.0 0.0 0.0
5 No 0.0 0.0 0.0

________________________________________________________________________________________________

Average Burning Rate: 0.0 mm/min

Sample Size: 102mm x 356mm

Sample Thickness: ≤7mm on all samples

Direction relative to sample: Transverse

Composite Sample: Yes

Conclusion

On the basis of the tests carried out this sample meetsthe requirements of BS AU 169a:1992 ISO 3795 1989. PASS

This report is made solely on the basis of your instructions and/or information and materials supplied by you. It is not inte nded to be a recommendation for any particular
course of action. Intertek does not accept a duty of care or any other responsibility to any person other than the Client in respect of this report and only accepts liability to
the Client insofar as is expressly contained in the terms and conditions governing Intertek's provision of services to you. Intertek makes no warranties or representations
either express or implied with respect to this report save as provided for in those terms and conditions. We have aimed to conduct the Review on a diligent and careful basis
and we do not accept any liability to you for any loss arising out of or in connection with this report, in contract, tort, by statute or otherwise, except in the event of our
gross negligence or willful misconduct.

Report No.: LEHTX00900653 Page 2 of 2

You might also like