REQUIRED GATE OPENING

PLANT CAPACITY : 100 TPH

GATE
SIZE OF EQUATION OF
PROPORTION( % ) OUTPUT REQUIRED (TPH) "Y" OPENING(%)
AGGREGATE LINE(From Graph )
"x"

40MM 35% 35.0 y = 0.386x+3.78 81


20MM 15% 15.0 y = 0.387x-5.07 52
10MM 22% 22.0 y = 1.45x-5.05 19
Stone Dust 28% 28.0 y = 1.51x-5.6 22
PLANT CAPACITY : 90 TPH
GATE
SIZE OF EQUATION OF
PROPORTION( % ) OUTPUT REQUIRED (TPH) "Y" OPENING(%)
AGGREGATE LINE(From Graph )
"x"
40MM 35% 31.5 y = 0.386x+3.78 72
20MM 15% 13.5 y = 0.387x-5.07 48
10MM 22% 19.8 y = 1.45x-5.05 17
Stone Dust 28% 25.2 y = 1.51x-5.6 20
PLANT CAPACITY : 80 TPH
GATE
SIZE OF EQUATION OF
PROPORTION( % ) OUTPUT REQUIRED (TPH) "Y" OPENING(%)
AGGREGATE LINE(From Graph )
"x"

40MM 35% 28.0 y = 0.386x+3.78 63


20MM 15% 12.0 y = 0.387x-5.07 44
10MM 22% 17.6 y = 1.45x-5.05 16
Stone Dust 28% 22.4 y = 1.51x-5.6 19
PLANT CAPACITY : 70 TPH
GATE
SIZE OF EQUATION OF
PROPORTION( % ) OUTPUT REQUIRED (TPH) "Y" OPENING(%)
AGGREGATE LINE(From Graph )
"x"

40MM 35% 24.5 y = 0.386x+3.78 54


20MM 15% 10.5 y = 0.387x-5.07 40
10MM 22% 15.4 y = 1.45x-5.05 14
Stone Dust 28% 19.6 y = 1.51x-5.6 17