Service Manual: Split System Air Conditioner
Service Manual: Split System Air Conditioner
Service Manual: Split System Air Conditioner
by Nemko
CONTENTS
1. Specifications..........................................................................................................2
2. Outline and Dimensions.......................................................................................11
3. Operation ..............................................................................................................20
4. Wiring Diagram.....................................................................................................44
5. Refrigerant Cycle..................................................................................................50
6. Control Block Diagram .........................................................................................51
7. Trouble Shooting...................................................................................................53
8. Key Components of Electronic Circuit .................................................................87
9. Disassembly Instructions .....................................................................................90
1) Indoor Unit ........................................................................................................90
2) Outdoor Unit .....................................................................................................97
3) Exploded Diagram (Indoor Unit)....................................................................100
4) Exploded Diagram (Outdoor Unit).................................................................116
5) Control Box Assembly....................................................................................124
1. SPECIFICATIONS
◆DSB-070LH/071LH
MODEL
DSB-070LH /071LH
ITEM
Class T
Capacity W 2,051/2,051
Btu/h 7,000/7,000
Starting Current A 18
Type Rotary
Capacitor 25µF/370VAC
Control Capillary
Refrigerant
(R-22)
Charge Q'ty g 850
Type Flare
Connection
OD (Liquid/Gas) in(mm) 1/4 (6.35) 3/8 (9.52)
2
◆DSB-091LH/092LH
MODEL
DSB-091LH /092LH
ITEM
Class T
Capacity W 2,637/2,637
Btu/h 9,000/9,000
Starting Current A 24
Type Rotary
Control Capillary
Refrigerant
(R-22)
Charge Q'ty g 800
Type Flare
Connection
OD (Liquid/Gas) in(mm) 1/4 (6.35) 3/8 (9.52)
3
◆DSB-121LH/122LH
MODEL
DSB-121LH/122LH
ITEM
Class T
Capacity W 3,663/3,956
Btu/h 12,500/13,500
Starting Current A 37
Type Rotary
Control Capillary
Refrigerant
(R-22)
Charge Q'ty g 1,060
Type Flare
Connection
OD (Liquid/Gas) in(mm) 1/4 (6.35) 1/2 (12.7)
4
◆DSB-123LH
MODEL
DSB-123LH
ITEM
Class T
Capacity W 3,517/3,810
Btu/h 12,000/13,000
Starting Current A 37
Type Rotary
Control Capillary
Refrigerant
(R-22)
Charge Q'ty g 1,230
Type Flare
Connection
OD (Liquid/Gas) in(mm) 1/4 (6.35) 3/8 (9.52)
5
◆DSB-182LH
MODEL
DSB-182LH
ITEM
Class T1
Capacity W 5,129/5,422
Btu/h 17,500/18,500
Starting Current A 49
Type Rotary
Control Capillary
Refrigerant
(R-22)
Charge Q'ty g 1,480
Type Flare
Connection
OD (Liquid/Gas) in(mm) 1/4 (6.35) 1/2 (12.7)
6
◆DSB-182LH-R
MODEL
DSB-182LH-R
ITEM
Class T1
Capacity W 5,275/5,275
Btu/h 18,000/18,000
Starting Current A 54
Type Recipro
Control Capillary
Refrigerant
(R-22)
Charge Q'ty g 1,550
Type Flare
Connection
OD (Liquid/Gas) in(mm) 1/4 (6.35) 1/2 (12.7)
7
◆DSA-183LH-R
MODEL DSA-183LH-R
ITEM
Class T1
W 5275.5/5422 4500/5400
Capacity
Btu/h 18,000/18,500 15354/18425
Type Recipro
Control Capillary
Refrigerant
(R-22)
Charge Q'ty g 1500
Type Flare
Connection
OD (Liquid/Gas) in(mm) 1/4 (6.35) 1/2 (12.7)
8
◆DSB-240LH-R
MODEL
DSB-240LH-R
ITEM
Class T1
Capacity W 7,034/7,034
Btu/h 24,000/24,000
Type Recipro
Type Flare
Connection
OD (Liquid/Suction) in(mm) 3/8 (9.52) 5/8 (15.9)
9
◆DSA-240LH-R
MODEL DSA-240LH-R
ITEM
Class T1
W 7,034/7,034 5,129
Capacity
Btu/h 24,000/24,000 17.5
Type Recipro
Control Capillary
Refrigerant
(R-22)
Charge Q'ty g 2,100
Type Flare
Connection
OD (Liquid/Gas) in(mm) 3/8 (9.52) 5/8 (15.9)
10
Plate Mounting
2. OUTLINE AND DIMENSIONS
750 REMOCON
11
Grille Insert
Frame Grille
Body
1 INDOOR UNIT
◆DSB-070LH/DSB-091LH
Plate Mounting
245
179
Plate Mounting
750 REMOCON
12
Grille Insert
Frame Grille
Body
◆DSB-071LH/DSB-092LH
Plate Mounting
245
179
Connecting Pipe
REMOCON
925
13
Plate Mounting
Body
Frame Grille
Grille Insert
◆DSB-121LH/122LH
285
Filter - L Filter - R 194
◆DSB-123LH
14
Connecting Pipe
REMOCON
1035
15
Grille Insert
Body
◆DSB-182LH/LH-R
322
430 REMOCON
710 Plate Mounting
◆DSA-183LH-R/DSB-240LH-R/DSA-240LH-R
1080
16
Body
Frame Grille
Grille Insert
298
200
Filter-L Filter-R
2 OUTDOOR UNIT
◆DSB-070LH/071LH/091LH/092LH/121LH/122LH/123LH
17
Inlet
320
Inlet
Guide Support
Cabinet Side Panel Top
Outlet
Foot
18
◆DSB-182LH/LH-R/DSA-183LH-R
Outlet 615
800
Service Valve
Foot Cushion
Inlet
323
380
foot
Cabinet front Service Cover
19
Cabinet Side
◆DSB-240LH-R/DSA-240LH-R
699
Service valve
873
3. OPERATION
1 NAME AND FUNCTION OF PARTS
Indoor Unit
◆DSB-070LH/DSB-091LH
Deodorizing Filter(Option)
Electrostatic Filter(Option) Removes bad smells from the
Removes dust and particles Air Inlet air.
from the air
Lamp
Fan Direction Remote
Antibacterial Filter (Up, Down) Controller
Removes dust and Receiver
prohibits germs.
REMOTE CONTROLLER
Remote Controller
20
◆DSB-071LH/DSB-092LH
Deodorizing Filter(Option)
Electrostatic Filter(Option) Removes bad smells from the
Removes dust and particles Air Inlet air.
from the air
Lamp
Fan Direction Remote
Antibacterial Filter (Up, Down) Controller
Removes dust and Receiver
prohibits germs.
REMOTE CONTROLLER
Remote Controller
21
◆DSB-121LH/122LH
;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;
;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;; ;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;
;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;
;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;
;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;; ;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;
;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;
;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;; ;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;
;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;; ;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;
22
◆DSB-123LH
Lamp
Power Plug
REMO
TE CONT
ROLL
Remote Controller
ER
23
◆ DSB-182LH/DSB-182LH-R
Deodorizing Filter
Removes bad
smells from the air.
Electrostatic Filter Test/Emergency/
Removes dust Remote Switch
particles from the air. Air In Slide to select
the desired position.
Indoor Cover
Fan Direction
(Left/Right)
.
MP
TE
/OFF
ON
DE
MO
P
R. EE
SL
N DI
FA T
D SE
EE RE EL
N SP NC
FA R CA
TE
EN
ER F
TIM OF
ON
24
◆ DSA-183LH-R/DSB-240LH-R/DSA-240LH-R
Deodorizing Filter
Removes bad
smells from the air.
Electrostatic Filter
Removes dust
particles from the air. AIR IN
Indoor Cover
DE LD
MO O/MI
RB
TU
ER
P
EE TIM R/ EL
SL TE NC
EN CA
/OFF
ON
LCD Remote
Controller Power Plug
25
◆DSB-070LH/DSB-091LH
EMR. REMOCON
26
◆DSB-071LH/DSB-092LH
EMR. REMOCON
27
◆DSB-121LH/122LH
28
◆ DSB-123LH
REMOCON
EMERGENCY
REMOCON
EMERGENCY
29
◆ DSB-182LH/182LH-R
EMERGENCY REMOTE
Timer
Quick
Airclean
ON
■ There is a switch panel at inside of Front Panel.
At the time of operating, open the Front Panel.
Timer (Yellow) ON (Red) Emergency switch can be used when the remote
Lights during the time Lights when the controller is lost or Testing.
reservation mode. operation is going on.
Remote switch is usually used by remote controller.
Quick (Red) Air clean (Green)
Lights during the
time Quick
Mode.
30
◆DSB-240LH-R/DSA-240LH-R
EMERGENCY
REMOCON
31
Outdoor Unit
◆ DSB-070LH/071LH/DSB-091LH/092LH/DSB-121LH/122LH/123LH
Connection Cover
Remove cover to access the
AC connection
AIR IN to the indoor unit.
Connection Wire
Drain Hose
Service Valves
The indoor and outdoor units
are connected by copper tubes
which are connected here.
32
◆ DSB-182LH/LH-R / DSA-183LH-R
AC Cover
Remove cover to
access the AC
AIR IN
connection from
this unit to the
indoor unit.
Connection Wire
Drain Hose
COPPER TUBING
AIR OUT
Service Valves
The indoor and outdoor
units are connected by
copper tubes which are
connected here.
Grounding Screw
Ground the unit here.
Ground Wire
(Not supplied)
33
◆DSB-240LH-R / DSA-240LH-R
Connection wire
Air Inlet
Drain Hose
Air Outlet
Connection Pipe
34
2 REMOTE CONTROLLER
Name of Each Button
◆DSB-070LH/DSB-071LH/DSB-091LH/DSB-092LH/DSB-121LH/
DSB-122LH/DSB-123LH/DSA-183LH-R/DSB-240LH-R/DSA-240LH-R
AUTO Display
Displays information
pertaining to unit.
ON/OFF Button
Press to turn the unit
on or off.
TEMPERATURE Buttons
FAN SPEED Button Press to raise or lower
Press to select the fan speed the desired temperature.
(High " ", Middle " ", MODE FAN SPEED FAN DIR.
Low " "). FAN DIR. Button
MODE Button SLEEP
Press to select up/down
Press to cycle through the modes TIMER direction for fan.
(Auto/Quick/Cooling/Fan/Dry)
ON/OFF ENTER/ TURBO/MILD
CANCEL TURBO/MILD
SLEEP Button Press to select super power
Press to set the unit for operation(Turbo) mode
the sleep mode.
35
◆DSB-182LH/182LH-R
AUTO Display
Displays information
pertaining to unit.
ON/OFF Button
Press to turn the unit
on or off.
TEMPERATURE Buttons
FAN SPEED Button Press to raise or lower
Press to select the fan speed the desired temperature.
(High " ", Middle " ", Low " ", MODE FAN SPEED FAN DIR.
FAN DIR. Button
Natural). Press to select up/down
direction for fan.
MODE Button SLEEP FAN DIR.
Press to cycle through the modes TIMER FAN DIR. Button
(Auto/Quick/Cool/Fan/Dehumidifier/ Press to select left/right
Heat) ON/OFF ENTER/
CANCEL
TURBO/MILD direction for fan.
SLEEP Button TURBO/MILD
Press to set the unit for Press to select super power
the sleep mode. operation(Turbo) mode
36
3 REMOTE CONTROLLER DISPLAY
◆DSB-070LH/DSB-071LH/DSB-091LH/DSB-092LH/DSB-121LH/
DSB-122LH/DSB-123LH/DSA-183LH-R/DSB-240LH-R/DSA-240LH-R
AUTO
FAN Indicators
FAN DIRECTION Indicators
Light to indicate
Light to indicate the
the fan speed.
fan direction.
NATURAL Indicator
Light to indicate the
speeds simulating a breeze.
TIMER Indicators (Include sleep)
Light to indicate the timer function mode.
AUTO
FAN Indicators
FAN DIRECTION Indicators
Lights to indicate
Lights to indicate the
the fan speed.
fan direction.
NATURAL Indicator
Lights to indicate the
speeds simulating a breeze.
TIMER Indicators (Include sleep)
Lights to indicate the timer function mode.
Replacing Batteries
LL
ER
MO
TE
CO
NT
RO
LL
ER
37
4 DESCRIPTION OF FUNCTIONS
OFF-Timer
If you set time in OFF-Timer Mode, the unit will stop at the set time.
Unit ON
ON
Unit OFF
OFF
ON-Timer
If you set time in ON-Timer Mode, the unit will run at the set time.
Unit ON
ON
Unit OFF
OFF
-1°C +1°C
0°C (RT-DT) -1°C +1°C
0°C (RT-DT)
(COOLING) HEATING
(3) During the time of test operating, Fan (Indoor, Outdoor) and Compressor is running regardless of room
temperature.
Buzzer
If the Indoor Unit Display receive the signal of Remote Controller, you can hear the signal "beep –" or "beep,
beep".
(1) In the case of receiving ON/OFF signal-"beep" "beep"
(2) And so on-"beep"
38
Fan Speed (Indoor Unit)
(1) Motor speed (Super high speed, high speed, normal speed, low speed, ultra low speed).
(2) Remote controller setting fan speed. (Auto, L, M, H, Natural)
(3) Relation of operating mode between fan speed. (legned: X-no relation)
DEHUMI-
FAN ONLY COOL AUTO QUICK HEAT
DIFICATION
H H H L H H H
M M M L M H M
L L L L L H L
(COOLING)
H
(HEATING)
H
39
Sleep Mode
(1) When you are going to sleep, select sleep switch and the unit controls the room to the desired temperature.
(The unit will not operate after 4 hour)
(2) For changing the temperature.
DT +0.5°C DT
+0.5°C –0.5°C
+0.5°C –0.5°C
–0.5°C
(3) To cancel sleep mode, press the SLEEP button again or press the MODE button once.: the SLEEP
indicator will disappear in the display.
Emergency Operation
(1) When the remote controller is lost, damaged or the battery is discharged, the Emergency operation can be
used to run the unit.
(2) The setting conditions of Emergency operation are as follows.
• Operation mode: Quick
• Preset temperature:18°C: Cooling, 32°C: Heating)
• Fan speed: High
You cannot operate with remote controller.
When the unit operates at low ambient temperature, frost may appear on the Evaporator. When the indoor coil
temperature is lower than 0°C at the end of 10 minutes of continuous compressor operation from the start, the
microcomputer of the unit stops the compressor to protect the unit from the frost. The control procedure for
indoor coil freeze protection.
-1°C +7°C
In normal operation, there is a time delay of three minutes between turn off and turning back on including initial
power up.
Auto Mode
(1) In Auto Mode
After the indoor fan is operated for 20 seconds in the Auto Mode the unit will operate automatically by selecting
operating Mode according to the room temperature
(RT: Room temperature)
41
Dehumidification Mode
COOLING POSITION
42
Self-Diagnostic Function
The control will contain diagnostic test to verify the integrity of the system.
43
4. WIRING DIAGRAM
Indoor Unit
◆DSB-070LH/091LH ◆DSB-071LH/092LH
44
◆DSA-181LH/182LH/182LH-R
DSA-181LH/182LH/183LH-R ◆DSA-240LH-R, DSB-240LH-R
45
Outdoor Unit
◆DSA-121LH/122LH, DSB-070LH/071LH
DSB-091LH/092LH/121LH/122LH ◆DSB-123LH/123PH
◆DSA-181LH/182LH
DSB-181LH/182LH/182PH ◆DSA-182LH-R/183LH-R, DSB-183LH-R/183LH-R
◆DSA-240LH-R/240PH-R
DSB-240LH-R/240PH-R
46
1 MAIN ELECTRIC PARTS
◆DSB-070LH/071LH
◆DSB-091LH/092LH
PART NAME PART CODE SPEC. QUANTITY REMARK
Fan Motor 3108003800 YDK-8-4B 1
Indoor Fan Motor Capacitor 3106900300 1.0uF 400VAC 1
Fuse 5FVLB3152L 250V 3.15A 1
Unit Stepping Motor 3108003900 GSP-24SW-061 1
Terminal Block 3108912301 SN-DBW-05P 1
3RC0020KE0 RBB100A001 1
Compressor
3107101900 RBB100A011 1
Fan Motor 3108004100 YDK-30-6B 1
Outdoor 3109502010 1.8+30µF 400VAC 1
Dual Capacitor
Unit 3109502030 1.8+35µF 400VAC 1
Terminal Block 3108912301 SN-DBW-05P 1
Reversing Valve 3104401010 CHV-0104 1
Solenoid coil 3109700110 CHV01AJ 1
◆DSB-121LH/122LH
PART NAME PART CODE SPEC. QUANTITY REMARK
Fan Motor 3108001220 YDK-8-4B/A 1
Fan Motor Capacitor 3106900300 1.0uF 400VAC 1
Indoor Fuse 5FVLB3152L 250V 3.15A 1
Unit Transformer 5EPV050100 220V/18V 1
Stepping Motor 3108000100 MP28GA (L=400mm) 1
Terminal Block 3108912301 SN-DBW-05P 1
Compressor 3100030CE0 RCB150A001 1
Fan Motor 3108000800 YDK-40-4B 1
Outdoor Dual Capacitor 3109500700 3.5+25µF 400VAC 1
Terminal Block 3108912301 SN-DBW-05P 1
Unit
Reversing Valve 3105401000 VH7-A TYPE 1
Solenoid coil 1
47
◆DSB-123LH
PART NAME PART CODE SPEC. QUANTITY REMARK
Fan Motor 3118003500 RP13B 1
Indoor Fan Motor Capacitor CMXW2G155K 1.5uF 400VAC 1
Fuse 5FVLB3152L 250V 3.15A 1
Unit Stepping Motor 3108003910 MP24GA 1
Terminal Block 3118900200 JXO-CH-2P 1
Compressor 3100030CE0 RCB150A001 1
Fan Motor 3108000800 YDK-40-4B 1
Outdoor Dual Capacitor 3109500700 3.5+25µF 400VAC 1
Unit Terminal Block 3108912301 SN-DBW-05P 1
Reversing Valve 3105401000 VH7-A TYPE 1
Solenoid coil 1
◆DSB-182LH/182LH-R
◆DSB-183LH-R
PART NAME PART CODE SPEC. QUANTITY REMARK
Fan Motor 3108007500 IC-9430DWKF7A 1
Fan Motor Capacitor 3106902400 2uF 400VAC 1
Indoor Fuse 5FVLB3152L 250V 3.15A 1
Unit Transformer 5EPV050120 DWA220B 1
Stepping Motor 3108007600 GSP-24RW-062 1
Terminal Block 3108912320 SN-DBW-4P 1
Compressor 3100068110 AWG5519EXN 1
Fan Motor 3108000521 IC-1625DWCF6B 1
Outdoor Dual Capacitor 3116902500 4+25µF 440VAC 1
Unit Terminal Block 3108912300 SN-DBW-3P 1
Reversing Valve 3105400310 STF-0201 1
Solenoid coil 3109700110 CHV-01AJ506BT 1
48
◆DSB-240LH-R
PART NAME PART CODE SPEC. QUANTITY REMARK
Fan Motor 3108003800 220/50/60Hz 1
Fan Motor Capacitor 3106902400 2.0uF 400VAC 1
Indoor Fuse 5FVLB3152L 250V 3.15A 1
Unit Transformer 5EPV050120 230V/50Hz 1
Stepping Motor 3108007600 GSP-24RW-062 1
Terminal Block 3108912320 SN-DBW-4P 1
Compressor 3100068201 AWG-5530EXC 1
Fan Motor 3108001500 220V/60Hz 1
Outdoor Dual Capacitor 3100902500 5/30µF 400VAC 1
Terminal Block 3108912320 SN-DBW-4P 1
Unit
Reversing Valve 3105400310 CHV-0201 1
Solenoid coil 3109700110 CHV-01AJ506B1 1
◆DSA-240LH-R
PART NAME PART CODE SPEC. QUANTITY REMARK
Fan Motor 3108007500 IC-9430DWKF7A 1
Fan Motor Capacitor 3106902400 2µF 400VAC 1
Indoor Fuse 5FVLB3152L 250V 3.15A 1
Unit Transformer 5EPV050120 230V/50Hz 1
Stepping Motor 3108007600 GSP-24RW-082 1
Terminal Block 3108912320 SN-DBW-4P 1
Compressor 3100068300 AWG5524EXN 1
Fan Motor 3108005800 OSME986DERC 1
Outdoor Dual Capacitor 3109504810 5/35µF 400VAC 1
Terminal Block 3108912320 SN-DBW-4P 1
Unit
Reversing Valve 3105400310 CHV-0201 1
Solenoid coil 3109700110 CHV-01AJ506B1 1
49
5. REFRIGERANT CYCLE
Note) If the pipe length exceeds the standard length, add 30g of refrigerant per extra meter.
Model Name
Contents DSB-070LH/071LH DSB-091LH/092LH DSB-121LH/122LH DSB-123LH DSB-240LH
Cool IDØ1.2 x L700 IDØ1.4 x L900 IDØ1.8 x ODØ3.2 x 500L IDØ1.8 x L1,200 IDØ2.0 x ODØ3.2 x 600L
Capillary Tube
Heat IDØ1.2 x L700 IDØ1.4 x L900 IDØ1.8 x ODØ3.2 x 900L IDØ1.8 x L800 IDØ2.0 x ODØ3.2 x 300L
Charge Quantity 850 g 800 g 1,060 g 1,230 g 2,050 g
Temp. Setting
ON/OFF
Room air temp.
SLEEP
Indoor coil temp.
REMOCON
Outdoor coil
temp
Circuit for signal receiver
51
◆DSB-121LH/DSB-122LH/DSB-182LH/182LH-R/
DSA-183LH-R/DSB-240LH-R/DSA-240LH-R
Temp. Setting
ON/OFF
Room air temp.
SLEEP
Indoor coil temp.
REMOCON
Outdoor coil
temp
Circuit for signal receiver
YES YES
Does
NO YES
the compressor run
normally?
Is the Place the switch
53
press the power ON/OFF switch position NO position to the
YES button on remote controller on switch pannel at "Remote" and then
"Remote" Check it once
YES more
Indoor unit does NO
not run(note 1) YES
NO
Is the unit YES
display Does the
Normal
mormal? beeper beep two
times? Does
NO Check the failure control PCB
code according to status LED repeat one
check the YES NO
the self diagnostic second "on and
(note 2) connecting off"?
YES point of
magnetic • control PCB fault
NO Is the display
contactor • Micom or reset
all off? IC fault YES
YES
Self-Diagnostic Function
• Error Code •
1 When the compressor do not run.
i) Check the voltage between L and Y of terminal block.
(Indoor Unit, Outdoor Unit)
ii) Check connecting wire of indoor unit and outdoor unit.
iii) Check relay RL1 on power P.C.B
2 Check fixing of indoor coil thermistor.
3 Check the GAS LEAKAGE of the pipe.
54
Neither Indoor Unit nor Outdoor Unit Runs
Yes
Yes
Press the ON/OFF switch of
No
Remote Control Check according to
self Diagnostic function
Is the indoor unit display all off?
55
Outdoor Unit Runs but Indoor Fan does Not Run
YES
Normal
Run again
No
Check the starting of indoor fan motor Normal
Run again
56
Outdoor Fan and Compressor Do Not Run
Check compressor,
outdoor fan motor individually
57
Only Compressor does not Run
OK
58
PCB DRIVING DESCRIPTION
1 PCB CIRCUIT DIAGRAM
◆DSB-071LH, 092LH
◆DSB-123LH
◆DSB-121LH/DSB-122LH
◆DSB-182LH/182LH-R/DSA-183LH-R/DSB-240LH-R/DSA-240LH-R
◆DSB-071LH PART LIST (INDOOR UNIT)
64
PART NAME SPEC QTY LOC.
DIODE 1N4007 TAPE 1 D3
DIODE UF203 1 D2
DIODE ZENOR 1N5241B 1 ZD1
DIODE ST01D-200 1 D1
C-CERA 2200pF, 250V 1 CY1
CHOKE COIL 1mH, 0.5A 1 L1
FILTER EMI 0.6*10*3TURN 1 L2
BUZZER BM-20K 1 BZ1
COIL 130uH, 3A 1 L3
IC REGULATOR KIA7805P 1 IC3
TR KRC102M 1 TR1
IC RESET KIA7042P 1 IC5
RELAY US11-12S 2 RL3,4
RELAY UKH-12S 1 RL1
SW TRANS 264P,1916 1 TRS1
CAPACITOR 2.0uF,400VAC CAP1
CAPACITOR 1.5uF,400VAC CAP1
CAPACITOR 1uF,400VAC 1 CAP1
PCB CONTROL 165.5X140X1.6T PCB
PCB CONTROL 162.5X140X1.6T 1 PCB
IC SWITCHING TNY264P 1 IC2
DIODE BRIDGE S1NB80 1 BD1
TRIAC SM3JZ47 1 T1
PHOTO COUPLER TLP560J 1 PT1
IC DRIVE TD62004AP 2 IC4,IC6
RESONATOR CST8.00MGW 1 OSC
IC MICOM TMP87C846AN 1 IC1
PHOTO COUPLER TLP421 2 PC1,PC2
65
◆DSB-092LH PART LIST (INDOOR UNIT)
66
PART NAME SPEC QTY LOC.
DIODE 1N4007 TAPE 1 D3
DIODE UF203 1 D2
DIODE ZENOR 1N5241B 1 ZD1
DIODE ST01D-200 1 D1
C-CERA 2200pF, 250V 1 CY1
CHOKE COIL 1mH, 0.5A 1 L1
FILTER EMI 0.6*10*3TURN 1 L2
BUZZER BM-20K 1 BZ1
COIL 130uH, 3A 1 L3
IC REGULATOR KIA7805P 1 IC3
TR KRC102M 1 TR1
IC RESET KIA7042P 1 IC5
RELAY US11-12S 2 RL3,4
RELAY UKH-12S 1 RL1
SW TRANS 264P,1916 1 TRS1
CAPACITOR 2.0uF,400VAC CAP1
CAPACITOR 1.5uF,400VAC CAP1
CAPACITOR 1uF,400VAC 1 CAP1
PCB CONTROL 165.5X140X1.6T PCB
PCB CONTROL 162.5X140X1.6T 1 PCB
IC SWITCHING TNY264P 1 IC2
DIODE BRIDGE S1NB80 1 BD1
TRIAC SM3JZ47 1 T1
PHOTO COUPLER TLP560J 1 PT1
IC DRIVE TD62004AP 2 IC4,IC6
RESONATOR CST8.00MGW 1 OSC
IC MICOM TMP87C846AN 1 IC1
PHOTO COUPLER TLP421 2 PC1,PC2
67
◆DSB-123LH PART LIST (INDOOR UNIT)
68
PART NAME SPEC QTY LOC.
DIODE 1N4007 TAPE 1 D3
DIODE UF203 1 D2
DIODE ZENOR 1N5241B 1 ZD1
DIODE ST01D-200 1 D1
C-CERA 4700pF, 250V 2 CY1,CY2
CHOKE COIL 1mH, 0.5A 2 L1,L2,L4
BUZZER BM-20K 1 BZ1
COIL 130uH, 3A 1 L3
COIL UU,40mH 1 L5
IC REGULATOR KIA7805P 1 IC3
TR KRC102M 1 TR1
IC RESET KIA7042P 1 IC5
RELAY US11-12S 2 RL3,4
RELAY UKH-12S 1 RL1
SW TRANS 264P,1916 1 TRS1
CAPACITOR 1.5uF,400VAC 1 CAP1
PCB CONTROL 165.5X140X1.6T 1
IC SWITCHING TNY264P 1 IC2
DIODE BRIDGE S1NB80 1 BD1
TRIAC SM3JZ47 1 T1
PHOTO COUPLER TLP560J 1 PT1
IC DRIVE TD62004AP 2 IC4,IC6
RESONATOR CST8.00MGW 1 OSC
IC MICOM TMP87C846AN 1 IC1
PHOTO COUPLER TLP421 2 PC1,PC2
69
◆DSB-182LH/182LH-R/DSA-183LH-R/DSB-240LH-R/DSA-240LH-R PART LIST(INDOOR UNIT)
70
No PART CODE PART NAME SPEC Q'TY UNIT REMARK
IC5 1KA7042P-- IC RESET KIA7042P 5L 1 EA
IC6 1KD65004AP IC DRIVER KID65004AP 1 EA
L1 52C1374001 COIL 130UH 3A 1 EA
OSC 4850103610 RESONATOR CST8.00MTW,8MHZ 1 EA
PCB 3104398102 PCB CONTROL 160.5*140*1.6T.1(42) 1 EA
PT1 1TLP560J-- IC PHOTO COUPLER TLP 560J 1 EA
R-OPT 3104810000 RESISTOR OPTION NOTE OPTION TABLE 1 ST
R1 RD-4K101J- R CARBON FILM 1/4 100 OHM J 1 EA
R10 RN-4K1272F R METAL FILM 1/4 12.7K OHM F 1 EA
R11 RN-4K1272F R METAL FILM 1/4 12.7K OHM F 1 EA
R12 RD-4K102J- R CARBON FILM 1/4 1K OHM J 1 EA
R13 RD-4K562J- R CARBON FILM 1/4 5.6K OHM J 1 EA
R14 RD-4K102J- R CARBON FILM 1/4 1K OHM J 1 EA
R15 RD-4K102J- R CARBON FILM 1/4 1K OHM J 1 EA
R16 RD-4K102J- R CARBON FILM 1/4 1K OHM J 1 EA
R17 RD-4K102J- R CARBON FILM 1/4 1K OHM J 1 EA
R18 RD-4K102J- R CARBON FILM 1/4 1K OHM J 1 EA
R19 RD-4K102J- R CARBON FILM 1/4 1K OHM J 1 EA
R2 RD-4K562J- R CARBON FILM 1/4 5.6K OHM J 1 EA
R20 RD-4K102J- R CARBON FILM 1/4 1K OHM J 1 EA
R21 RD-4K102J- R CARBON FILM 1/4 1K OHM J 1 EA
R23 RD-4K102J- R CARBON FILM 1/4 1K OHM J 1 EA
R24 RD-4K102J- R CARBON FILM 1/4 1K OHM J 1 EA
R25 RD-4K102J- R CARBON FILM 1/4 1K OHM J 1 EA
R26 RD-4K102J- R CARBON FILM 1/4 1K OHM J 1 EA
R27 RD-4K102J- R CARBON FILM 1/4 1K OHM J 1 EA
R28 RD-4K102J- R CARBON FILM 1/4 1K OHM J 1 EA
R29 RD-4K102J- R CARBON FILM 1/4 1K OHM J 1 EA
R3 RD-4K103J- R CARBON FILM 1/4 10K OHM J 1 EA
R30 RD-4K102J- R CARBON FILM 1/4 1K OHM J 1 EA
R31 RD-4K102J- R CARBON FILM 1/4 1K OHM J 1 EA
R32 RD-4K102J- R CARBON FILM 1/4 1K OHM J 1 EA
R38 RS01F121J- R M-OXIDE FILM 1W 120 OHM J 1 EA
R4 RD-4K102J- R CARBON FILM 1/4 1K OHM J 1 EA
R5 RD-2K102J- RESISTOR 1/2W - 1K 1 EA
R6 RD-4K331J- R CARBON FILM 1/4 330 OHM J 1 EA
R7 RD-4K331J- R CARBON FILM 1/4 330 OHM J 1 EA
R8 RD-4K331J- R CARBON FILM 1/4 330 OHM J 1 EA 070LH,091LH,240LH-R
R9 RN-4K1272F R METAL FILM 1/4 12.7K OHM F 1 EA 070LH,091LH,240LH-R
RA1 RA8K5103J- RESISTOR ARRAY 6A 103J 1 EA
RA2 RA8K4103J- RESISTOR ARRAY 5A 103J 1 EA
RA3 RA8K3103J- RESISTOR ARRAY 4A 103J 1 EA
RL1 5SC0101220 RELAY UKH-12SP 1 EA
RL1 5SC0101128 RELAY CS11-12SH 1C 1P 1 EA 240L-R/LH-R
RL2 5SC0101128 SW RELAY CS11-12SH 1C 1P 1 EA
RL3 5SC0101128 SW RELAY CS11-12SH 1C 1P 1 EA
SCRW 7122401211 SCREW TAPPING T2S TRS 4*12 MFZN 1 EA
T1 TSM3JZ47-- TRIAC SM3JZ47 1 EA
TEST 3108804300 WAFER YF254S-02 1 EA
TR1 TKRC102M-- TR KRC 102-M (TAPPING) 1 EA
VAR D15G561K-- VARISTOR 15G561K/350V 1 EA
WSHR 3106002900 WASHER 3*6 1 EA
71
◆CONTROL PCB ASS`Y (MODEL : 082M/H,102M/H,122M/H,151L,122L/LH,182L/L-R,182LH/LH-R)
72
No PART CODE PART NAME SPEC Q'TY UNIT REMARK
R2 RD-4K103J- R CARBON FILM 1/4 10K OHM J 1 EA
R20 RN-4K1272F R METAL FILM 1/4 12.7K OHM F 1 EA
R21 RD-4K331J- R CARBON FILM 1/4 330 OHM J 1 EA
R22 RN-4K1272F R METAL FILM 1/4 12.7K OHM F 1 EA 122LH,182LH/LH-R
R23 RD-4K331J- R CARBON FILM 1/4 330 OHM J 1 EA 122LH,182LH/LH-R
R26 RD-4K102J- R CARBON FILM 1/4 1K OHM J 1 EA
R3 RD-4K102J- R CARBON FILM 1/4 1K OHM J 1 EA
R32 RD-4K102J- R CARBON FILM 1/4 1K OHM J 1 EA
R33 RD-4K102J- R CARBON FILM 1/4 1K OHM J 1 EA
R34 RD-4K102J- R CARBON FILM 1/4 1K OHM J 1 EA
R4 RD-4K102J- R CARBON FILM 1/4 1K OHM J 1 EA
R5 RD-4K102J- R CARBON FILM 1/4 1K OHM J 1 EA
R6 RD-4K102J- R CARBON FILM 1/4 1K OHM J 1 EA
R7 RD-4K102J- R CARBON FILM 1/4 1K OHM J 1 EA
R8 RD-4K102J- R CARBON FILM 1/4 1K OHM J 1 EA
R9 RD-4K102J- R CARBON FILM 1/4 1K OHM J 1 EA
RA1 RA8K5103J- RESISTOR ARRAY 6A 103J 1 EA
RA2 RA8K3103J- RESISTOR ARRAY 4A 103J 1 EA
TEST 3108804300 WAFER YF254S-02 1 EA
TR1 TZTC3198Y- TRANSISTOR KTC3198Y-(1815Y) 1 EA 182L/L-R, 182LH/LH-R
TR2 TKRC102M-- TR KRC 102-M (TAPPING) 1 EA 182L/L-R, 182LH/LH-R
73
◆POWER PCB ASS`Y (MODEL : 122L/LH,151L,182L/L-R,182LH/LH-R,082M/H,102M/H,122M/H)
74
◆LED PCB ASS`Y (MODEL : 070L/LH, 071LH, 091L/LH, 092LH, 052M/H)
No PART CODE PART NAME SPEC Q'TY UNIT REMARK
CC1 CDXE1H104M C-MULTI CR501B-Z5U,104Z,50V 1 EA
CN1 3108804800 WAFER SMAW250-08 1 EA
HOLD 3103002700 HOLDER LED ABS 1 EA
L1 DDLS05031D LED DLSO-5031D(RED) 1 EA
L2 DDLG05031D LED DLG-5031D(GRN) 1 EA
L3 DDLS05031D LED DLSO-5031D(RED) 1 EA
L4 DDLY05031D LED DLY-5031D(YLW) 1 EA
PCB 3104398201 PCB LED 110*31*1.6T.10(288) 1 EA
RCV 1TSP1838YA RECEIVER MODULE TSOP-1838YA1(HOLDER) 1 EA
SW1 5S40202000 S/W PUSH JPS2281 1 EA
75
Power Supply(1)
G
+ + +
3.15A D4 D3 104 16V
104 35V 25V 104
1000µF 470µF 100µF
POWER TRANS
DESCRIPTION
DC Power Supply in circuit needs +12V and +5V. +12V is used for Compressor Driving Relay, Triac Driving
Photo Triac, Buzzer Driving Swing, Sweep Motor. AC voltage of secondary Power Transformer is rectified by
Bridge Diode, and it is filtering by Main Condensor CE1.
Filtered DC voltage is about +18V, is regulated +12V DC by Regulator IC7812.
And it is regulated +5V DC by Regulator IC7805.
VAR is serge filter and CC1, CC2, CC3 is Noise filter.
Oscillator(2)
5V
19
CC13
OSC 104
20
8M
76
DESCRIPTION
VDD-10%
VSS+10%
Fig 2-1
Sensor(3)
070LH,091LH
182LH, 240LH
330 R8
23
R9 CC7
O/C SENSOR
CN10 12.7kF 103 MICOM
103
CN9 CC6
24
I/C SENSOR R10 R7 330
12.7KF
25
ROOM SENSOR R11 R6 330
12.7KF CC5
103
DESCRIPTION
-5 1.127 1.127
0 1.378 1.378
5 1.650 1.650
10 1.936 1.936
15 2.228 2.228
Table 3-1
77
Triac Driving(4)
12V
N
TLP561 L1 AC 220V
PT1 1 2 L
130µH
3A
MICOM SN1
0.1µF
T1 120Ohm
IC4 SM3JZ47
KID 65004
2 15 R5 TO MOTOR
38
1K
1/2W
DESCRIPTION
Number 38 Terminal of Micom is put out Pulse Output, by way of Buffer it is driving Photo Triac is supplied
Trigger Signal.
Trigger Test of Triac is detected Zero Cross Part of AC input and it is triggered from Zero Cross part to Time
delay part according to Fan Speed. (Ref. Fig 4-1) SN1 is Snubber.
AC220V
TRIGGER
LOW
LOWSPEED
SPEED MEDIUM SPEED
MEDIUM SPEED HIGH
HIGHSPEED
SPEED
MOTOR
INPUT
Fig 4-1
78
Remote Controller(5)
DESCRIPTION
Signal from Remote Controller put in only Control Data Signal at Micom Terminal of Number 33, which is gotten
fid of Carrier (38KHz) from Receive Module. Signal Wave repeat third as following Fig 5-1.
But in Secondary Wave Custom Code is Reversed Face.
Selecting Mode(6)
5V
RA1
R14
MICOM 1K
MODE
13 SELECT
P2 PUSH S/W
CA1
F4104Z
DESCRIPTION
79
Micom Power Supply(7)
5V
VDD 42 +
CE5 CC11
10µF 104
16V
41
40
MICOM 39
OSC 19
8MHz
20
21
VSS 22 CC13
104
DESCRIPTION
MICOM Power is supplied 5V at Number 42 using VDD, Number 19, 20 Vsing Oscillator, CC13 is noise filter.
80
Reset(8)
MICOM
R13 5.6K
1K R12
7042P 18
IC5 CC9
10.3
CE4
4.7uF/50V
DESCRIPTION
Voltage less than about 0.8V put in Micom Terminal of Number 18 and then Micom reset. Reset IC detect
Power ON and Voltage less than 4.25V, and then send Reset Signal.
Vcc (+5V)
4.25V
t
DELAY TIME
FOR POWER ON
H RESET
L t
POWER
ON
81
Function Selecting(9)
CA3 RA3
F3 104Z 4A 103J RA3
41
R32 1K JS5
40 MILD/HIGH
R31 1K JS4
39 HEAT/COOL
R30 1K
MICOM
F5 104Z 6A 103J
CA1 RA1 R36 heat/low
30
1K R28
model R35 cool/low
JS3 1K R17 29
14 1K R25
R34 heat/high
JS2 1K R16 28
15 1K R24
R33 cool/high
JS1 1K R15 27
16 1K R23
RA2
CA2 R37 monitoring
26
1K R29
DESCRIPTION
Buzzer Driving(10)
VCC
12V
DESCRIPTION
MICOM
R4
1K BZ1
KID 65004 Micom 34 Terminal put out Buzzer Driving Pulse,
34
6 11 its output is driving Buzzer through Buffer.
Ocillatory Frequency of buzzer is selected by
internal Micom.
This unit is setting at 4KHz.
82
Zero Crossing Detect(11)
VCC
R3
TR1 10K
KRC120M
R27
2
D5 1K MICOM
1 2 1 31
3
TRANS
OUTPUT
1
D6 R2 CC4 2 1
5.6K 103
2
DESCRIPTION
It defect Zero Cross part of Trans output voltage, Transistor TR1 is used to put in the Micom.
Detail Driving is as following Fig 11-1.
R19 is Resistance to limit current.
AC18V
The
Number
31 of H
Micom
terminal
DETECT POINT
Fig 11-1
83
Stepping Motor Driving(12)
12V
CN13
1
IC6
2 B+
1 3 Ø1
M1
2 4 Ø2 FOR SWING
MICOM
3 5 Ø3
4 6 Ø4
KID65004
DESCRIPTION
There are one Stepping Motor for Flap (up and down) and it is used 4 face Drive Method.
It is driving as following Fig 12-1. (Ring Count Method of 8 Status)
Ø4
Ø3
Ø2
Ø1
84
2 REMOTE CONTROLLER ASSMBLY FUNCTIONAL TEST METHOD
TEST START No
Power supply again
Power Supply
Is Display at the No
beginning ON?
Select ON/OFF button
Check the Following
Yes BATTERY SPRING
Is Display at the No MICOM
beginning ON? PCB
LCD
No
Is it normal? ERROR
No
Is it normal? ERROR
No
Is it normal? ERROR
Is display at the No
ERROR
begining ON?
No
Is it normal? ERROR
85
No
Is LCD display OFF? ERROR
No
Is it normal ERROR
No
TIMER display? ERROR
No
Is all display OFF? ERROR
No
Is it normal? ERROR
SLEEP MODE No
ERROR
Display ON?
Is display at the No
ERROR
beginning ON?
TEST OK!
86
8. KEY COMPONENTS OF ELECTRONIC CIRCUIT
(1) U1 (MICOM)
1 P77(HSO) VDD 42
87
(2) U2, 4 (KID65004) DARLINGTON ARRAYS
IN1 1 16 OUT 1
KID65004AP
IN2 2 15 OUT 2
COMMON
IN 3 3 14 OUT 3 INPUT
OUTPUT
IN 4 4 13 OUT 4 10.5KΩ
IN5 5 12 OUT 5 7.2KΩ
3KΩ
IN6 6 11 OUT 6 GND
IN7 7 10 OUT 7
GND 8 9 COMMON FREE
WHEELING DIODES (Equivalent Circuit)
(Top View)
SCHEMATIC DIAGRAM
INPUT
100K 500 100 100 10K
240
INPUT
10K 10K
210
16K
100
300 200
36K
64K 300
50K
012
520 50 200
40
pF OUTPUT
60K
26K
29K
Pin 1. INPUT 20K
2. GROUND
3. OUTPUT 20K
GND
(Equivalent Ciircuit)
88
(5) U9 (KIA7042P) : RESET IC
1 VCC
KIA70
42P 3 OUT
2 GND
INPUT
GROUND OUTLINE
OUTPUT
89
9. DISASSEMBLY INSTRUCTIONS
1 INDOOR UNIT
◆DSB-070LH/DSB-091LH
PROCEDURES PHOTOS
1. Stop the operation of the Air conditioner and disconnect the power cord
from the wall
outlet.
Fig 1
Fig 4
4. Removing the Drain Pan. (Fig 4)
1 Disconnect the Body drain hole. (left and right Body)
2 Disconnect three hooks and remove the Drain Pan.
Fig 5
5. Removing the Indoor Evaporator. (Fig 5~6)
1 Remove the screw fixed at the indoor Evaporator of the Body.
2 Remove the hook fixed at the Bracket Pipe of the back of Body.
3 Remove Indoor Evaporator.
Fig 6
6. Removing the Cross Flow Fan. (Fig 7)
1 Remove set screw fixed at the Motor shaft.
2 Remove Cross Flow Fan.
90
◆DSB-071LH/DSB-092LH
PROCEDURES PHOTOS
1. Stop the operation of the Air conditioner and disconnect the power cord
from the wall
outlet.
Fig 1
Fig 4
4. Removing the Drain Pan. (Fig 4)
1 Disconnect the Body drain hole. (left and right Body)
2 Disconnect three hooks and remove the Drain Pan.
Fig 5
5. Removing the Indoor Evaporator. (Fig 5~6)
1 Remove the screw fixed at the indoor Evaporator of the Body.
2 Remove the hook fixed at the Bracket Pipe of the back of Body.
3 Remove Indoor Evaporator.
Fig 6
6. Removing the Cross Flow Fan. (Fig 7)
1 Remove set screw fixed at the Motor shaft.
2 Remove Cross Flow Fan.
91
◆DSB-121LH/DSB-122LH
PROCEDURES PHOTOS
1. Stop the operation of the Air conditioner and disconnect the power cord
from the wall outlet.
Fig 1
2. Removing the Insert Grille and Frame Grille. (Fig 1~2)
1 Draw up the Insert Grille and remove it.
2 Loosen two special screws fixed at the Cover Ter-Block.
3 Loosen three screws fixed at the Body.
4 Remove the Frame Grille. Fig 2
92
◆DSB-123LH
PROCEDURES PHOTOS
1. Stop the operation of the Air conditioner and disconnect the power cord
from the wall
outlet.
Fig 1
Fig 4
4. Removing the Drain Pan. (Fig 4)
1 Disconnect the Body drain hole. (left and right Body)
2 Disconnect three hooks and remove the Drain Pan.
Fig 5
5. Removing the Indoor Evaporator. (Fig 5~6)
1 Remove two screws fixed at the indoor Evaporator of the Body.
2 Remove the hook fixed at the Bracket Pipe of the back of Body.
3 Remove Indoor Evaporator.
Fig 6
6. Removing the Cross Flow Fan. (Fig 7)
1 Remove set screw fixed at the Motor shaft.
2 Remove Cross Flow Fan.
93
◆DSB-182LH/DSB-182LH-R
PROCEDURES PHOTOS
1. Stop the operation of the Air conditioner and disconnect the power cord
from the wall outlet.
Fig 2
3. Removing the Control Box.
1 Disconnect indoor room and coil thermistors. (Fig 3)
2 Disconnect the fan motor lead wire from connection at the main
PCB. (Fig 3)
3 Disconnect the swing motor connection wire.
4 Loosen the screw fixed at the ground wire.
Fig 3
5 Loosen two screws fixed at the body.
Fig 6-1
94
PROCEDURES PHOTOS
Fig 7
Fig 8
95
◆DSB240LH-R/DSA-240LH-R
PROCEDURES PHOTOS
1. Stop the operation of the Air conditioner and disconnect the power cord
from the wall outlet.
Fig 1
2. Removing the Insert Grille and Frame Grille. (Fig 1~2)
1 Draw up the Insert Grille and remove it.
2 Loosen the screws fixed at the Cover Ter-Block.
3 Loosen two screw at the Frame Grille.
4 Remove the Frame Grille. Fig 2
Fig 7
96
2 OUTDOOR UNIT
◆DSB-070LH/071LH/DSB-091LH/092LH/DSB-121LH/122LH/123LH
PROCEDURES PHOTOS
1.Stop the operation of the air conditioner and disconnect the wire from
Indoor Unit to Outdoor Unit.
Fig 6
Fig 7
97
◆DSB-182LH/182LH-R/DSA-183LH-R
PROCEDURES PHOTOS
1.Stop the operation of the air conditioner and dis connect the wire from in
door unit to out door unit.
Fig 2
3. Removing the Propeller Fan. (Fig 3)
1Loosen the screw fixed at the motor bracket.
2Remove the Plain Washer.
3Remove the Propeller Fan.
Fig 6
98
◆DSB-240LH-R/DSA-240LH-R
PROCEDURES PHOTOS
1.Stop the operation of the air conditioner and disconnect the wire from in
door unit to out door unit.
Fig 6
99
3 EXPLODED DIAGRAM (Indoor Unit)
◆DSB-070LH/DSB-091LH
100
◆DSB-070LH/DSB-091LH PART LIST(INDOOR UNIT)
101
◆DSB-071LH/DSB-092LH
102
◆DSB-071LH/DSB-092LH PART LIST(INDOOR UNIT)
103
◆DSB-121LH
104
◆DSB-121LH/122LH PART LIST(INDOOR UNIT)
105
No PART CODE PART NAME Q'TY SPEC REMARK
NO 15, 15-11, 16, 26, 28 Will be changed depend on export destination & buyer requirements.
106
◆DSB-123LH
107
◆DSA-123LH PART LIST (INDOOR UNIT)
13 3113309800 PIPE ARTRON HOSE 1 O.D •’32 I.D •’20 T=6, F-PE
3110059400 1 DSB-123L
3110059420 1 DSB-123PH
108
No PART CODE PART NAME Q'TY SPEC REMARK
3114302020 1 DSB-123L
3114302210 1 DSB-123PH
109
◆DSB-182LH/LH-R
v
x
110
◆DSB-182LH/LH-R Parts List (Indoor Unit)
111
No PART CODE PART NAME Q'TY SPEC REMARK
112
◆DSA-183LH-R/DSB-240LH -R/DSA-240LH-R
113
◆DSA-183LH-R/DSB-240LH-R/DSA-240LH-R PART LIST (INDOOR UNIT)
1 3100400600 BODY 1
11 3100089100 EVAPORATOR 1
17 3107600500 FLAP UP 2
20 3100702000 BUSHING 2
114
No PART CODE PART NAME Q'TY SPEC REMARK
32 2150013200 AL FOIL EMI 0.1 AL100P (W100XL100)
115
4 EXPLODED DIAGRAM (Outdoor Unit)
◆DSB-070LH/071LH/DSB-091LH/092LH/DSB-121LH/122LH/123LH
116
◆DSB-070LH/071LH/DSB-091LH/092LH/DSB-121LH/122LH/123LH PART LIST(OUTDOOR UNIT )
117
No PART CODE PART NAME Q'TY SPEC REMARK
118
◆DSB-182LH/182LH-R/DSA-183LH-R
;;
;;;;
; ;
119
◆DSB-182LH/182LH-R/DSA-183LH-R Parts List (Outdoor Unit)
3118100220 DSB-182LH-R,
DSA-183LH-R
8 3105300100 SUPPORTER MOTOR 1 SGCC T1.0
120
No PART CODE PART NAME Q'TY SPEC REMARK
3110010700 DSB-182LH
19 PIPE DISCHARGE ASS’Y 1
3110010800 DSB-182LH-R, DSA-183LH-R
3 HITACHI DSB-182LH
28 3101500800 GROMMET COMP
4 TECUMSEH DSB-182LH-R, DSA-183LH-R
3 DSB-182LH
29 3107101120 COMP M8.4 x 22 x T1.6
4 DSB-182LH-R, DSA-183LH-R
3 DSB-182LH
30 3107101130 NUT COMP M8 x P1.25 MEZN
4 DSB-182LH-R, DSA-183LH-R
121
23
8
9
5
16 7
10
4
16-5
3
16-4 25
16-6 16-2 15
12
14
122
18
16-3 24
20 13
16-1
1 11
19
◆DSB-240LH-R/DSA-240LH-R
2
17
24
21
◆DSB-240LH-R/DSA-240LH-R PART LIST (OUT DOOR UNIT)
123
5 CONTROL BOX ASSEMBLY
◆DSB-070LH/071LH/DSB-091LH/092LH
0
9
4
8
7
6
L Y 1 2
2 q
w
124
◆DSB-070LH/071LH/DSB-091LH/092LH
125
◆DSB-121LH/DSB-122LH
126
◆DSB-090LH/DSB-121LH/DSB-122LH
127
◆DSB-123LH
128
◆DSB-123LH
AC250V, 10/16A
2 3111312110 POWER CORD 1
H0.5V V-F x 1mm2
129
◆DSB-182LH/182LH-R
130
◆DSB-182LH/182LH-R
131
◆DSA-183LH-R/DSB-240LH-R/DSA-240LH-R
3
13
7
4
6
9
10
5
11
12
132
◆DSA-183LH-R/DSB-240LH-R/DSA-240LH-R
133
DEAWOO ELECTRONICS CO., LTD
686, AHYEON-DONG MAPOGU,
SEOUL, KOREA.
C.P.O. BOX 8003 SEOUL KOREA
TELEX: DWELEC K28177-8
CABLE:"DAEWOOELEC"
FAX: +82-2-364-5588
TEL: +82-2-360-7114, 8114
http://www.dwe.daewoo.co.kr
S/M NO. : 3113907100 PRINTED DATE: MAY. 2001