Location via proxy:   [ UP ]  
[Report a bug]   [Manage cookies]                

Catálogo ACE 6000

Download as pdf or txt
Download as pdf or txt
You are on page 1of 4

ACE6000

Commercial & Industrial Electricity Meter

ACE6000 four-quadrant load profiling Wide Range of Applications


meters support the new needs arising from Thanks to an auto-ranging power supply
deregulation and competition in the and wide measuring range,
electricity market as well as classic a single meter type can be used across
metering. a variety of applications – from large
commercial installations to industrial
Smart metering.
Compliant with IEC standards, these
meters include large innovative capabilities. Accuracy and linearity ensure high
They allow multiple recording of load quality billing data, (including Load
profiles along with local and remote Profiles).
communication.
Instantaneous values for a variety of
Flexible quantities serve as a base for network
Designed for direct or transformer monitoring.
connection, ACE6000 meters employ
a scalable architecture that makes them PSTN, GSM, GPRS and IP
equally suitable for use with existing and communications are supported thanks to
new electricity distribution networks. DLMS-Cosem Protocol.
Adding value
Through the application of the latest-generation metrological and communications
technologies, ACE6000 meters bring significant benefits to utilities and end-users alike, adding
value to every aspect of the metering process.

Utility Benefits
Reduced Inventory Cost
Thanks to a wide measuring range and auto-ranging power supply, industrial and commercial
users need only one type of meter for many types of installations.

Reduced Data Collection Cost


Read cycles are kept to a minimum by internal storage of all billing data, and powerful
communications capabilities permit low-cost remote meter reading. Conformance with
the latest IEC DLMS-Cosem communications standards ensures that the meters can be easily
integrated into standard data collection systems as well as future GPRS or IP based systems.

Reduced Non-Technical Losses


Multiple safety features guard against technical problems being introduced by human
intervention.

Feature Upgrades
ACE6000 meters include an upgrade engine to further enhance functionality. Upgrade costs
can be kept to a minimum through the re-use of existing equipment.

Withstand Adverse Environments


Our meters are designed and tested to cope with severe environmental conditions, such as
electromagnetic disturbances and network condition variations.

End-User Benefits
Excess Consumption Feature
ACE6000 meters can monitor consumption against configurable thresholds and can activate
contacts if consumption exceeds limits.

Instantaneous values such as Power Factor, Demand, Volts and Amps are made available for
the end-user to help him monitor his consumption.
Key Features ACE6000 Meter series

Multi-Energy Basic version without outputs with 1 serial

Internal measurement of active and reactive power in each direction. port


Flexible version with 4 outputs and 1

Load Profiles serial port


Serial port can either be RS232 or RS485
Can store up to sixteen channels of load profile for various base quantities.

Multi-Rate
- Multi-rate billing for energy and demand.
- Ten base quantities can be submitted to billing.
- 32 energy-rate registers and 24 demand-rate registers are available.
- Rate switching mainly performed by internal clock.

Communications
- Two communication channels.
- Local- and remote-reading ports.
- External telephone modem can be supplied from the meter, (PSTN, GSM).
- DLMS-Cosem compliance opens to GPRS and IP networks.
Commercial & Industrial applications

Software
Actaris offers a complete range of associated software:
- ACE PRO for reading and programming
- Compatibility with AMR systems already deployed
Dimensions Technical Data
Ratings Voltage: 3*57.7/100V up to 3*240/415V auto ranging
Direct current: Ib 5A, Imax 100A (under special wiring conditions)
Ct/connection: Ib 2.5A, Imax 10A
Network types Direct connection: 4-wire meter, fully operational in 3-wire connection
without neutral
C/t, v/t connection: 3- and 4-wire configurable connections
Accuracy Direct connected: Active energy Class 1
Transformer connected: Active energy Class 0.5S & Class 1
Reactive energy: Class 2
Frequency 50 / 60 Hz
Temperature range -40°C to +70°C
Real Time Clock Back up with external removable battery and internal super capacitor
Compliant with IEC 61038
Standards Full compliance with IEC 62052-11 and IEC 62053-21/22/23 and CE marking
standards (mechanical, climatic, electrical, electromechanical, metrological)
Communications IR-port (IEC 62056/21 and IEC 62056/42-46-53-61-62)
RS232C or RS485 DLMS-Cosem, Protocol (IEC 62056/42-46-53-61-62)

EL-0177.0-GB-02.05 - © Copyright 2005, Actaris, All Rights Reserved. - Actaris reserves the right to change these specifications without prior notice.
Accessories
Communications External telephone modem
Cabling for external communications devices
IR-reading device for connection to PC
Configuration/Calibration ACE PRO Utility software for configuration and reading
Documentation Test certificate
User guide
Installation manual

Please note, these specifications are valid only after confirmation from Actaris

Actaris SAS
ZI de Chasseneuil - Avenue des Temps Modernes
86361 Chasseneuil du Poitou cedex - France t e l +33 5 49 62 70 00
For more information, see www.actaris.com fax +33 5 49 62 70 89

You might also like