Specification NF S94-080-1
Specification NF S94-080-1
Specification NF S94-080-1
NF S94-080-1
January 1997
AFNOR
Association Française de Normalisation
www.afnor.fr
S94-080-1
Surgical implants
Titanium alloy TA6V
ICS: 11.040.40
Surgical implants
Titanium alloy TA6V
Replaces the experimental specification with the same index dated October
1994.
Cross reference
Analysis This document defines the characteristics of bars and rods in titanium alloy
for surgical implant.
Corrections
Edited and distributed by the Association Française de Normalisation (AFNOR), Tour Europe 92049 Paris La Défense Cedex
Tel.: 01 42 91 55 55 – International tel.: +33 1 42 91 55 55
AFNOR S93Q
This document specifies the characteristics and test methods corresponding to the products to be
forged or machined in titanium alloy, elaborated in the form of bars or rods (alloy TA6V), used for the
manufacture of surgical implants.
2 Specification references
This document includes by dated or non dated reference provisions from other publications. These
specification references are cited in the appropriate sections in the text and the publications are listed
below. For the dated references, later amendments or reviews of any of these publications only apply
to this document if they have been incorporated by amendment or review. For the non dated
references, the last edition of the publication referred to applies.
NF EN 10002-1 Metal materials – Traction test – Part 1: Test method (at room temperature)
(classification index: A 03-001).
NF A 06-931 Steel and cast iron – Total carbon assay – Infrared absorption method after
combustion in an induction oven.
NF A 06-650 Titanium and titanium alloys chemical analysis – Hydrogen assay.
NF A 06-651 Titanium and titanium alloys chemical analysis – Oxygen assay.
NF A 06-652 Titanium and titanium alloys chemical analysis – Aluminium in Ti-Al-V alloys
assay – Volumetric EDTA method.
NF A 06-653 Titanium and titanium alloys chemical analysis – Iron assay – Molecular
absorption spectrometry method.
NF A 06-654 Titanium and titanium alloys chemical analysis – Nitrogen assay – Volumetric
method.
NF A 06-656 Titanium and titanium alloys chemical analysis – Vanadium in Ti-Al-V alloys
assay – Volumetric method.
NF A 08-650 Titanium and titanium alloys chemical analysis – Aluminium, vanadium and iron
elements in TA6Vgrade alloys – Flame Atomic absorption spectrometry or plasma
emission spectrometry method.
E 05-015 State of the surface of the products – Prescriptions – Part 1: Generalities,
terminology, and definitions.
ETTC 2 Standard microstructures for titanium + alloys – European Titanium Producers
Technical Commission.
ETTC 5 Definition of a standard aeronautic quality (STQ) and the quality disks (DQ) for
titanium alloys - European Titanium Producers Technical Commission.
ETTC 6 Titanium and titanium alloy scraps treated for recycling – European Titanium
Producers Technical Commission.
ETTC 7 Regulations for the ultrasound control testing of titanium and titanium allow half-
products – European Titanium Producers Technical Commission.
ETTC 8 Titanium and titanium alloy metallography –European Titanium Producers
Technical Commission.
3 Definitions
3.1 bars
3.2 rods
The sponge, master alloys, addition elements and recycling materials sources must be certified by the
ingot manufacturer. The recycling of scraps and chips is authorised in accordance with document
ETTC 6.
The elaboration of the material must comply with the requirements of document ETTC 5, standard
quality.
6 Reception characteristics
NOTE: The specifications of the ISO 5832-3 specifications comply with the corresponding
specifications in table 1.
Table 1
The following control tests must be carried, unless there are special indications on the order:
a) Diameter tolerance
Table 2
Dimensions in millimetres
Diameter Tolerance
9 < 18 + 0.2
0
18 < 30 + 0.2
0
30 < 50 + 0.6
0
50 < 80 + 0.7
0
80 < 120 + 0.9
0
120 < 250 +1
0
250 +4
0
For the products ordered in unit or multiple lengths, the tolerance must be stated on the order.
c) Dressing-off tolerances
The maximum slag must be less than 2 mm per meter of the bar and less than 0.12 % of the total
length of the bar.
d) Shape tolerance
Local retouching is authorised on conditional that the depth does not exceed 3 % of the diameter. The
retouching must be open ended in shape, length 10 times to 20 times the depth of the retouched zone.
6.2 Examination of the surface for the products destined for forging
Table 3
Diameter Ra Rt
(mm) (m) (m)
50 Ra 1.6 Rt 12.5
50 < 100 Ra 3.2 Rt 16
> 100 Ra 6.4 Rt 32
The ultrasound control test must be carried out according to the instructions in document ETTC 7, and
in accordance with the client for products of a thickness less than or equal to 12 mm.
7 Test methods
The test methods to be used for the determination of the compliance with the specifications of this
document must be those given in table 4.
Table 4