Programmation Par Commandes AMOS ANG PDF
Programmation Par Commandes AMOS ANG PDF
AMOs
Contents
1 Access to the HiPath 4000 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5
1.1 HiPath 4300/4500 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5
1.2 HiPath 4000 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6
1.3 Access via the Customer LAN . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7
1.4 AMO access via the HiPath 4000 Assistant . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8
1.5 Direct AMO access via the customer LAN . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9
1.6 Direct AMO access via the Atlantic LAN. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11
1.7 Direct AMO access via V.24 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12
2 Syntax for AMO Input . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13
2.1 Example of AMO Input . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14
2.2 AMO SYNTAX DETAILS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15
2.3 Selecting Important Verbs and Nouns . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 17
3 Protection of software features (codeword) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 18
3.1 Feature description . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 18
3.2 Codeword variants . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 19
3.3 Codew description . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 21
3.4 Service information . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 22
3.5 Generation (example) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 23
3.6 Relevant AMO . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 28
4 Administration Software . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 29
4.1 Switching and Configuration AMOs in the CC . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 29
4.2 BCSU - Configuring Mounting Locations for Modules in the SWU . . . . . . . . . . . . . . . 30
4.3 Functions of the AMO . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 30
4.3.1 ADD-BCSU . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 30
1
EN4401EN00EN_0005
© 2005 Siemens AG
AMOs Siemens
4.3.2 CHANGE-BCSU. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 31
4.3.3 DELETE-BCSU . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 32
4.3.4 DISPLAY-BCSU. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 32
4.3.5 REGENERATE-BCSU . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 35
5 BSSU - Board Switch, Switching Unit . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 36
5.1 Functions of the AMO . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 36
5.1.1 ACTIVATE-BSSU. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 36
5.1.2 DEACTIVATE-BSSU . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 38
5.1.3 RESTART-BSSU . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 39
6 UCSU - Unit Configuration of Switching Unit . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 40
6.1 Functions of the AMO . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 40
6.1.1 ADD-UCSU . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 40
6.1.2 CHANGE-UCSU . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 44
6.1.3 DELETE-UCSU . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 44
6.1.4 DISPLAY-UCSU. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 45
6.1.5 REGENERATE-UCSU . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 47
7 USSU - Unit Switch of Switching Unit SWU . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 48
7.1 Functions of the AMO . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 48
7.1.1 ACTIVATE-USSU . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 49
7.1.2 DEACTIVATE-USSU . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 51
7.1.3 DISPLAY-USSU. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 53
7.2 SDSU Status Display of SWU . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 54
7.2.1 Example: Displaying the Status of Circuit 1 of a peripheral board . . . . . . . . . 55
8 AMOs in the User Area . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 56
9 Configuration of a subscriber . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 58
9.1 UP0/E - subscriber. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 58
9.2 Configuration of an IP-subscriber . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 62
10 Deletion of a subscriber . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 63
11 Structure of the DPLN . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 64
11.1 Overview of the CPS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 65
12 WABE - Digit Analysis . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 66
12.1 ADD-WABE . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 67
12.2 DISPLAY-WABE . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 67
12.3 REGENERATE-WABE . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 71
13 COSSU - Classes of Service . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 72
13.1 ADD-COSSU . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 72
13.2 CHANGE-COSSU . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 74
13.3 DELETE-COSSU. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 74
13.4 DISPLAY-COSSU . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 74
13.5 REGENERATE-COSSU . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 77
14 TAPRO - Key Programming . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 78
14.1 CHANGE-TAPRO . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 78
14.2 DISPLAY-TAPRO . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 80
14.3 REGENERATE-TAPRO . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 85
2
EN4401EN00EN_0005
© 2005 Siemens AG
Siemens AMOs
3
EN4401EN00EN_0005
© 2005 Siemens AG
AMOs Siemens
4
EN4401EN00EN_0005
© 2005 Siemens AG
Siemens Access to the HiPath 4000
MTS
ISDN
PPP-Link
SNS-Server
for HTS
WAML Customer-LAN
SNS-Server
Control
8
TAP V24 to RMX RMX
9
FAMOS
SCSI
10
Terminal V24 or UNIX
11 SL200
192.0.2.222 PPP-Link 221
using Script: Siemens.CPPP .5
.3 .4
Atlantic LAN 192.0.2.0
.6 SNS-Server
5
EN4401EN00EN_0005
© 2005 Siemens AG
Access to the HiPath 4000 Siemens
MTS
ISDN
PPP-Link
SNS-Server
for HTS
Customer-LAN
WAML
SNS-Server
Steuerung DSCXL
TAP Atlantik/Service LAN
10
Customer LAN
8/11
.5
.3 .4
Atlantic LAN 192.0.2.0
6
EN4401EN00EN_0005
© 2005 Siemens AG
Siemens Access to the HiPath 4000
Base Administration --> Unix Base Administration --> LAN Configuration --> LAN Cards
Information about the IP settings you will get from the LAN administrator.
Address: unique customer IP address
Netmask: depends on the IP class of the LAN card, e.g. for class C: 255.255.255.0
Broadcast: depends on the IP address of the LAN card. For the LAN card address 1.30.31.5
the Broadcast address is 1.30.31.255
7
EN4401EN00EN_0005
© 2005 Siemens AG
Access to the HiPath 4000 Siemens
8
EN4401EN00EN_0005
© 2005 Siemens AG
Siemens Access to the HiPath 4000
V.24 LAN
9
EN4401EN00EN_0005
© 2005 Siemens AG
Access to the HiPath 4000 Siemens
10
EN4401EN00EN_0005
© 2005 Siemens AG
Siemens Access to the HiPath 4000
11
EN4401EN00EN_0005
© 2005 Siemens AG
Access to the HiPath 4000 Siemens
12
EN4401EN00EN_0005
© 2005 Siemens AG
Siemens Administration: Syntax for AMO Input
13
EN4401EN00EN_0005
© 2005 Siemens AG
Administration: Syntax for AMO Input Siemens
14
EN4401EN00EN_0005
© 2005 Siemens AG
Siemens Administration: Syntax for AMO Input
Entry Modes
– POSITION-ORIENTATED ENTRY
(VERB-NOUN:value1,value2,,,value5,value n)
– KEYWORD-ORIENTATED ENTRY
(VERB-NOUN:name3=value3,name1=value1,name n=value n)
– Prompting (input request)
The POSITION-orientated entry consists of a sequence of parameters, each separated
by a comma. If a parameter is not to be assigned a value, the comma is still entered to
maintain the sequence, i.e. in the example above, value 3 and value 4 are represented by
commas.
With the KEYWORD-orientated entry the parameters to be entered are identified by en-
tering their respective keyword first, e.g. STNO=2104.
Since each parameter is attached to an identifying keyword, the sequence on the input line
is not important; any order is possible.
15
EN4401EN00EN_0005
© 2005 Siemens AG
Administration: Syntax for AMO Input Siemens
The colon ”:” is used to separate the AMO command code from the parameter block. The
semicolon ”;” is the command line termination character. When it is used, values for any
optional parameters which may be entered in the command line are not requested by the
system.
To enter the command line CTRL +C or the RETURN key ( ) is used depending on the
type of terminal.
Blanks between the different parts of the input (verb, hyphen, colon, parameter, equals sign,
comma, and semi-colon) may be used for subdividing the input.
The AMO will ask for Parameter Values if not all of the mandatory parameters have
been supplied with values as yet.
If you input a ’?’, the system will display all of the possible parameter values, and then
prompt for an entry.
A mixture of Position- and keyword-oriented inputs is not possible.
Before the first input with the AMO a system LOGON (CTRL + T) must be made.
16
EN4401EN00EN_0005
© 2005 Siemens AG
Siemens Administration: Syntax for AMO Input
B C S U
17
EN4401EN00EN_0005
© 2005 Siemens AG
Administration: Protection of software features (codeword) Siemens
The dongle or the SIM card and the codeword "tell" the system which feature packages and
quantities were purchased by the customer. When the system is configured, a special plausi-
bility check is used to ensure that the configuration data corresponds to the purchased features
and quantities.
18
EN4401EN00EN_0005
© 2005 Siemens AG
Siemens Administration: Protection of software features (codeword)
PNE
Voice com-
Entry Agent
pression IP
CODEWORD
In HiPath 4000 V2.0 and later, the CODEWORD will feature four variants:
1. Normal mode:
This is the approved operating mode as implemented in HiPath 1.0. In normal mode, a
codeword and licenses are requested for all relevant licenses in the database.
2. Trial mode:
This feature introduces a time-limited trial mode. When you activate trial mode, you can
skip the license restrictions that are temporarily displayed. During this time, the AMOs work
as if unrestricted licenses were available except that an advisory message is sent to the
users if license restriction violations occur.
3. Emergency mode:
The system activates the Emergency mode, in case of special situations.
Special situations are:
Validity of the Codeword is expired;
Dongle resp. SIM card is missing;
Codeword is missing;
19
EN4401EN00EN_0005
© 2005 Siemens AG
Administration: Protection of software features (codeword) Siemens
20
EN4401EN00EN_0005
© 2005 Siemens AG
Siemens Administration: Protection of software features (codeword)
21
EN4401EN00EN_0005
© 2005 Siemens AG
Administration: Protection of software features (codeword) Siemens
22
EN4401EN00EN_0005
© 2005 Siemens AG
Siemens Administration: Protection of software features (codeword)
● The expiry date is shown after each LOGON command or after the initial ADD command.
You can also check the date with the DISPLAY-CODEW command.
● A new codeword is needed every time the purchased quantity is expanded.
(Except "HIPATH AP VOICE COMPRESSION IP" where only the coding is dynamically
changed (from G.729 to G.711) when the limit is reached.)
The purchased quantity can be temporarily expanded in trial mode (see Section 1.2).
● An installed codeword only can be replaced by a new one. The creation date is saved in
the codeword; the serial number is used for information purposes only.
● The codeword can be changed with the codeword tool.
● The hardware ID and codeword must match.
● In order to enter a codeword the date of the system must be valid.
● In the event of contractual violation, the user interface is disabled and you are prevented
from starting any more SWU AMOs (for configuration).
● If the system prevents access although the codeword and dongle are valid, you can acti-
vate the dongle with the following actions: unplug/plug in the dongle, enable line8 or per-
form an A1 soft restart.
● Further information on the AMO CODEW can be found in the AMO description in the
service manual.
23
EN4401EN00EN_0005
© 2005 Siemens AG
Administration: Protection of software features (codeword) Siemens
DISPLAY-CODEW;
H500: AMO CODEW STARDED
CODEWORD: AFTKSB3CJYN4LKZN7GNWZH8TXH63M29A5GA2L2JN261LGKEA8CPHLZV5UGKHVPHP
XGRZDWDF83BG6BLE2U6LSP8GYS8VY5NADW88BUAE6RA58HXMD2N99TJSC9
VERSION : H205
SERIAL NUMBER: 7
HARDWARE ID : C6EB8F3B
ENTRY DATE : 22.02.2004
TRIAL MODE : NOT ACTIVATED
CONFIRMATION : 3706
+---------------------------------------------+-------+-------+-------+-------+
| | | | | |
| UNIT | CON- | USED | FREE |BLOCKED|
| | TRACT | | | |
+---------------------------------------------+-------+-------+-------+-------+
| COMSCENDO | 976 | 913 | 63 | |
| CORDLESS E | 0 | 0 | 0 | |
| PNE | 0 | 0 | 0 | |
| HIPATH PROCENTER ENTRY AGENT | 0 | 0 | 0 | |
| SIGNALING SURVIVABILITY | 0 | 0 | 0 | |
| CC-AP FOR AP EMERGENCY | 0 | 0 | 0 | |
+---------------------------------------------+-------+-------+-------+-------+
H07: THE TEST MODE IS AVAILABLE (ANOTHER) 2 TIMES.
24
EN4401EN00EN_0005
© 2005 Siemens AG
Siemens Administration: Protection of software features (codeword)
DISPLAY-CODEW;
DISPLAY-CODEW;
H500: AMO CODEW STARTED
CODEWORD: 3SK2N24LR9RF4G9919DZL3GN8C8SVWTN7RX7BWNBCTLTZPGMZN9FBXP97RRFTT72
R283HCUX6LSJXW5YD147WGWTV9FXD2CZBSWN7RY63VL9R7ASMWJ546YM7R
VERSION : H205
SERIAL NUMBER: 0
HARDWARE ID : 7ED439FB
ENTRY DATE : 07.01.2004
VALID UNTIL : 17.12.2005
TRIAL MODE : NOT ACTIVATED
CONFIRMATION : 0
+---------------------------------------------+-------+-------+-------+-------+
| | | | | |
| UNIT | CON- | USED | FREE |BLOCKED|
| | TRACT | | | |
+---------------------------------------------+-------+-------+-------+-------+
| COMSCENDO | | 110 | | |
| CORDLESS E | | 0 | | |
| PNE | | 0 | | |
| HIPATH PROCENTER ENTRY AGENT | | 0 | | |
| SIGNALING SURVIVABILITY | | 0 | | |
| CC-AP FOR AP EMERGENCY | | 0 | | |
+---------------------------------------------+-------+-------+-------+-------+
H12: CURRENT CODEWORD IS A TYPE 2 CODEWORD.
25
EN4401EN00EN_0005
© 2005 Siemens AG
Administration: Protection of software features (codeword) Siemens
Trial mode
The purchased quantity can be temporarily expanded with trial mode.
Trial mode is activated with CHANGE-CODEW. Utilization is not unlimited (maximum number
specified in codeword, generally 2) and has a maximum utilization time (generally 30 days).
SWU administration is not disabled even if license violation is shown in trial mode ("!!!!!" in the
"FREE" column). A mark that can be displaced with the AMO SDSU is applied to elements that
exceed the license limit (stations, trunks, etc.). The number of units marked is also displayed in
the AMO CODEW.
Trial mode is automatically terminated if not manually deactivated within the maximum time lim-
it. When this happens, marked elements are disabled for security reasons and can only be en-
abled if an appropriate codeword is set up.
No elements are marked or disabled for the features HIPATH PROCENTER ENTRY AGENT
and HIPATH AP VOICE COMPRESSION IP. However, when trial mode ends, no agents above
and beyond the license limits can log on and compressed connections cannot be set up.
Trial mode does not apply to the features HIPATH AP REMOTE SURVIVABILITY and CC-AP
FOR AP EMERGENCY. The codeword’s license limit cannot be exceeded here.
● Activate trial mode:
CHANGE-CODEW:TRIAL=YES;
....(activated after consultation)
26
EN4401EN00EN_0005
© 2005 Siemens AG
Siemens Administration: Protection of software features (codeword)
CODEWORD: 3SK2N24LR9RF4G9919DZL3GN8C8SVWTN7RX7BWNBCTLTZPGMZN9FBXP97RRFTT72
R283HCUX6LSJXW5YD147WGWTV9FXD2CZBSWN7RY63VL9R7ASMWJ546YM7R
VERSION : H205
SERIAL NUMBER: 0
HARDWARE ID : 7ED439FB
ENTRY DATE : 18.12.2003
VALID UNTIL : 17.12.2004
TRIAL MODE : NOT ACTIVATED
CONFIRMATION : 0
+---------------------------------------------+-------+-------+-------+-------+
| | | | | |
| UNIT | CON- | USED | FREE |BLOCKED|
| | TRACT | | | |
+---------------------------------------------+-------+-------+-------+-------+
| COMSCENDO | 110 | 110 | !!!!! | 1 |
| CORDLESS E | | 0 | | |
| PNE | | 0 | | |
| HIPATH PROCENTER ENTRY AGENT | | 0 | | |
| SIGNALING SURVIVABILITY | | 0 | | |
| CC-AP FOR AP EMERGENCY | | 0 | | |
+---------------------------------------------+-------+-------+-------+-------+
H12: THE TEST MODE IS AVAILABLE (ANOTHER) ONCE.
27
EN4401EN00EN_0005
© 2005 Siemens AG
Administration: Protection of software features (codeword) Siemens
DISPLAY-SDSU:STATUS=LICMARK,TYPE=PEN,LEVEL=PER3;
DISPLAY-SDSU:STATUS=LICBLOCK,TYPE=PEN,LEVEL=PER3;
....(specifies the stations disabled on account of license violation
when the trial mode expired.)
28
EN4401EN00EN_0005
© 2005 Siemens AG
Siemens Administration: Administration Software
4 Administration Software
29
EN4401EN00EN_0005
© 2005 Siemens AG
Administration: Administration Software Siemens
This AMO is used to configure peripheral modules, ringing current generator modules, and
SIUs in the LTU.
The module is entered in the SWU database (reference configuration) and, if the correct
module is plugged in, loaded and put into service.
4.3.1 ADD-BCSU
Assign the desired module type.
The LTU in which the module is to be configured must already be assigned. (AMO UCSU).
Caused by feature IPDA there are two different kind of LTUs from now on. The range for tradi-
tional LTUs in HHS (Hicom Host System) are from 1 to HW max. value which depends on the
particular platform - and AP shelves (Access Points). The range for these AP shelves starts
generally from 17 and goes up to 99.
During the load of a HHS shelf (Shelf Broadcast) no module can be configured in that shelf.
The AMO is canceled, producing an error message in case a configuration is attempted in that
state.
Assigning a SIU:
Assigning a SIU requires the actions as follows:
a) Manually blocking of LTU shelf (AMO USSU)
b) assigning a SIU
c) Putting the LTU shelf in service
30
EN4401EN00EN_0005
© 2005 Siemens AG
Siemens Administration: Administration Software
4.3.2 CHANGE-BCSU
Examples
1. Change the SLMA module with the code number Q2041-X and the parameters LTG=1,
LTU=1, SLOT=31 to an SLMA module with the code number Q2057-X100.
Input:
CHANGE-BCSU:PARTNO,1,1,31,,"Q2057-X100";
31
EN4401EN00EN_0005
© 2005 Siemens AG
Administration: Administration Software Siemens
2. Change all SLMA modules of LTG 1 with the code number Q2041-X to SLMA modules with
the code number Q2057-X100.
Input:
CHANGE-BCSU:PARTNO,1,,,"Q2041-X","Q2057-X100";
Output:
H01: BG 1.1. 25 CHANGED - IN SERVICE
H01: BG 1.1. 31 CHANGED - OUT OF SERVICE (NPR)
4.3.3 DELETE-BCSU
Example
1. Remove the RG module having the parameters LTG=1, LTU=1 and SLOT=19.
Input:
DELETE-BCSU:RG,1,1,19;
4.3.4 DISPLAY-BCSU
The type of output is controlled exclusively by parameter TYPE.
● Interrogate the configuration of an LTU with modules in the following format:
– a statistics
– a table
– a table of modules with variable modes
● Interrogate the operating mode RG, ACGEN, SIU- and DIUC- modules.
● Interrogate the connection status of pens.
● Interrogate base stations.
● Interrogate source groups (see also AMO-UCSU).
32
EN4401EN00EN_0005
© 2005 Siemens AG
Siemens Administration: Administration Software
Examples
1. Generate statistics of the reference configuration of the entire system. Parameters (LTG,
LTU, SLOT,CFIG and PARTNO) are assigned default values.
Input:
DISPLAY-BCSU:STAT;
Output:
TOTAL OF THE REFERENCE CONFIGURATION
Output:
ADDRESS : LTG 1 LTU 3 SOURCE GROUP 1
-----+-----------+---------+---+---+-+------------+-----+--------+------------+
| ASSIGNED | MODULE |FCT|HWY| | INSERTED | | | MODULE |
PEN | MODULE | TYPE |ID |BDL| | MODULE |STATE| HW-INFO| STATUS |
-----+-----------+---------+---+---+-+------------+-----+--------+------------+
19 | Q7065-X APPS |*| AVAILABLE | | | NPR |
25 | Q2117-X SLMS A |*| | | | NPR |
31 | AVAILABLE | | AVAILABLE | | | |
37 | AVAILABLE | | AVAILABLE | | | |
43 | Q2303-X STMI 1 A |*| | | | NPR |
+-----------------------------+-+------------+-----+--------+------------+
| IP ADDRESS : 198. 16. 16. 63 BCHLCNT : 20 |
33
EN4401EN00EN_0005
© 2005 Siemens AG
Administration: Administration Software Siemens
+-----------------------------+-+------------+-----+--------+------------+
49 | AVAILABLE | | AVAILABLE | | | |
55 | AVAILABLE | | AVAILABLE | | | |
61 | Q2303-X STMI 1 A |*| | | | NPR |
+-----------------------------+-+------------+-----+--------+------------+
| IP ADDRESS : 198. 16. 16. 64 BCHLCNT : 30 |
+-----------------------------+-+------------+-----+--------+------------+
67 | AVAILABLE | | AVAILABLE | | | |
73 | Q2248-X LTUCE | | Q2248-X | 1 | -A2 - | READY |
79 | Q2144-X SLMO A | | Q2144-X | 1 | -D1 - | READY |
85 | Q2158-X SLMO24 1 A |*| | | | NPR |
91 | Q2115-X SLMU16 A | | Q2115-X | 1 | C812-G | READY |
97 | Q2150-X SLMB A | | Q2150-X | 1 | C360-L | READY |
103 | Q2150-X SLMB A |*| | | | NPR |
109 | Q2141-X SLMA A | | Q2141-X | 1 | B008-D | READY |
115 | Q2025-X300 TMBD A |*| | | | NPR |
121 | Q2121-X TMBCT A |*| | | | NPR |
If there is an inconsistency between reference and actual configuration, the identifier ’*’ is
entered.
Only one status is output for the dependability and AM module status, which may consist of a
combination of states.
3. List the data for all modules in LTG 1 / AP shelf 32 (19" shelf).
Input:
DISPLAY-BCSU:TBL,1,32;
Output:
ADDRESS : LTG 1 LTU 32 SOURCE GROUP 6
-----+-----------+---------+---+---+-+------------+-----+--------+------------+
| ASSIGNED | MODULE |FCT|HWY| | INSERTED | | | MODULE |
PEN | MODULE | TYPE |ID |BDL| | MODULE |STATE| HW-INFO| STATUS |
-----+-----------+---------+---+---+-+------------+-----+--------+------------+
1 | AVAILABLE | | AVAILABLE | | | NPR |
34
EN4401EN00EN_0005
© 2005 Siemens AG
Siemens Administration: Administration Software
4.3.5 REGENERATE-BCSU
For program technical reasons configured base stations will be regenerated before all regular
boards.
Example
Regenerate all modules in the system.
Input:
REGENERATE-BCSU:;
Output:
ADD-BCSU:PER,1,1,61,"Q2144-X ",0,0,,NO,300,700,300,A;
ADD-BCSU:PER,1,1,67,"Q2158-X ",1,0,,NO,300,700,300,A;
ADD-BCSU:PER,1,1,73,"Q2115-X ",0,0,,NO,,,,A;
ADD-BCSU:PER,1,1,79&&85,"Q2150-X ",0,0,,,,,,A;
ADD-BCSU:PER,1,1,91,"Q2141-X ",0,0,,,,,,A;
ADD-BCSU:PER,1,1,97,"Q2025-X300",0,0,,,,,,A;
ADD-BCSU:PER,1,1,103,"Q2121-X ",0,0,,,,,,A;
ADD-BCSU:PER,1,2,31,"Q2117-X ",0,0,,,,,,A;
ADD-BCSU:PER,1,2,55,"Q2214-X ",0,0,,,,,,A;
ADD-BCSU:PER,1,2,61,"Q2208-X100",0,0,,,,,,A;
ADD-BCSU:DIU,1,2,79,"Q2096-X200",0,,,,,0,,,,,A;
ADD-BCSU:DIU,1,2,85,"Q2096-X200",0,,,,,0,,,,,A;
ADD-BCSU:DIU,1,2,91,"Q2096-X200",0,,,,,0,,,,,A;
ADD-BCSU:DIU,1,2,97,"Q2096-X200",0,,,,,0,,,,,A;
ADD-BCSU:PER,1,2,103,"Q2235-X ",0,0,,,,,,A;
ADD-BCSU:PER,1,2,109,"Q2235-X100",0,0,,,,,,A;
ADD-BCSU:DIU,1,2,115,"Q2096-X200",0,,,,,0,,,,,A;
ADD-BCSU:PER,1,2,121,"Q2174-X ",0,0,,,,,,A;
35
EN4401EN00EN_0005
© 2005 Siemens AG
Administration: BSSU - Board Switch, Switching Unit Siemens
5.1.1 ACTIVATE-BSSU
Individual modules are activated, i.e. any ’manual blocking’ status is removed. Hierarchically
subordinate trunks and terminals are also activated.
Before a module is activated, its status is checked. If it is manually blocked, the block is
removed.
If a pre-blocking is in effect for the module to be activated, the activate job removes the pre-
blocking.
Activation can be carried out:
● with conditional loading
● with unconditional loading
● without loading
In the case of an activate job with conditional loading, the trunk circuit data is only loaded when
necessary.
36
EN4401EN00EN_0005
© 2005 Siemens AG
Siemens Administration: BSSU - Board Switch, Switching Unit
After the activate job is executed, a message is output supplying information regarding the
switching state achieved. The message does not specify whether or not the deactivated module
had been manually blocked before the deactivate job.
STMI2-HFA boards
The AMO performs the activation (bring-into-service) action of a STMI2-HFA board from which
IP terminals have been automatically switched from. Because of a board error, either
– without switching back the IP terminals
– with switching back the IP terminals
This command is called after the defective board has been replaced by a board which is ex-
pected to be O.K.
HFASW = IPSTNBCK : AMO switchs (reconfigures) back the IP terminals which had been
originally configured at the specified board and activates the specified board. The DC state of
the specified (standby) board must be MAN_AMO/DEF, where the destination board ( from
which the IP terminals are switched from ) must be DEF or READY.
HFASW = STBYRDY : AMO activates the specified board and changes its Standby Mode
from ...STDBY_DEF to ...STDBY_READY.
HFASW = NONE : AMO just activates the STMI2-HFA board .
HFASW parameter is only valid for STMI2-HFA board, for the rest of the boards this parameter
is ignored.
Description <pen>:
<pen> = <LTG number>.<LTU number>.<Slot>
37
EN4401EN00EN_0005
© 2005 Siemens AG
Administration: BSSU - Board Switch, Switching Unit Siemens
Description of <state>:
DEF Module defect
NPR Module not present
UNACA Module blocked due to interrelationship
UNACH Module hierarchically blocked (superordinate unit blocked)
UA/UH Module blocked hierarchically and due to interrelationships
WBT Wrong board type found
Description of <loaderror>:
1 No load files for this module
2 Error occurred during data transmission
3 Fault in module hardware
Example
The module at LTG 1, LTU 2, SLOT 25 is to be activated with conditional loading.
Input:
ACTIVATE-BSSU:AT,1,2,25;
Output:
H02: MODULE 1.2.25 ACTIVATED
or
H12: MODULE 1.2.25 ACTIVATED - NOT OPERATIONAL (UNACH-NPR)
(The module is not operational since it is hierarchically blocked (UNACH) and not present
(NPR). Any existing manual block was removed.)
5.1.2 DEACTIVATE-BSSU
Individual modules are deactivated, i.e., the status ’manual blocking’ or ’pre-blocking’ is set.
When a module is deactivated, all the hierarchical blocks for subordinate units are also set.
Before a module is deactivated, its status is checked. If the module is in a state that does not
permit deactivation, a deactivate job is not issued and, after a corresponding message is sent
to the operator, the AMO is terminated.
Two types of deactivate jobs are possible:
Deactivate jobs with pre-blocking, i.e. existing connections are not released.
Deactivate jobs without pre-blocking, i.e., without regard for existing connections.
The operator receives an advisory message to say that the switching job is executed. The
message does not specify whether or not the deactivated module had been manually blocked.
38
EN4401EN00EN_0005
© 2005 Siemens AG
Siemens Administration: BSSU - Board Switch, Switching Unit
If the current reference clock generator is on the module(s) to be deactivated, and there are
other reference clock generators available outside the specified range, the optional parameter
REFOFF is prompted with the advisory H26.
The advisory H27 is prompted if the job affects all reference clock generators. In this case, a
prompt is also given if the value YES was specified when the AMO was started.
The operator can determine what the AMO is supposed to do using the values YES or NO for
the new parameter REFOFF.
The value YES means that if applicable, the module with the current reference clock generator
should also be deactivated.
The value NO means that the module with the current reference clock generator should not be
deactivated. In this case, the AMO responds with the advisory H28.
The value PROMPT (default value) means that the parameter should be prompted if the current
reference clock generator is within the specified range.
5.1.3 RESTART-BSSU
This function resets boards; that means the commands DEACTIVATE and ACTIVATE are
combined in one order. For ranges all devices will be deactivated first and activated afterwards.
All deactivations will be done with OFFTYPE= DI, all activations will be done with
ONTYPE=AUL. The last reference clock generator can not be reset by means of this function,
the message H28 will be displayed.
WTIME parameter is used to have a pause time between activation and deactivation process.
HFASW parameter is only valid for STMI2-HFA board, for the rest of the boards this parameter
is ignored.
Example
The module at LTG 1, LTU 2, SLOT 25 is to be activated with conditional loading.
Input:
RESTART-BSSU:1,2,25;
Output:
H23: MODULE 1.2.25 DEACTIVATED
H02: MODULE 1.2.25 ACTIVATED
39
EN4401EN00EN_0005
© 2005 Siemens AG
Administration: UCSU - Unit Configuration of Switching Unit Siemens
Note
The AMO itself determines in which type of system it is running and reacts accordingly.
6.1.1 ADD-UCSU
Create LTG
With the creation of an LTG the LTG status ’not equipped’ is cancelled and the LTG is assigned
the status ’not loaded’.
The LTG newly created by AMO UCSU can be placed into service by means of AMO USSU
following complete configuration.
Since EV3.0 only one LTG (LTG1) can be configured. The parameter itself will not be canceled
for certain reasons.
40
EN4401EN00EN_0005
© 2005 Siemens AG
Siemens Administration: UCSU - Unit Configuration of Switching Unit
Create LTU or AP
The data (module type, identification code) required for the creation of an LTU is read out of the
module table (UBGDAT) reloaded by the AMO and entered in the hardware structure memory
of the SWU database. Before an LTU is created the associated LTG must be set up.
The LTPARTNO parameter specifies which LTUC board will be added.
If the LTUC board doesn’t correspond to the system type the AMO will be aborted.
Possible LTUC boards:
PARTNO UNIT System type
Q2148-X LTUCE Compact shelf
Q2136-X SCC 80CM(X)
Q2166-X LTUCX SIPAC Compact shelf
Q2189-X100 LTUCC SIPAC Compact shelf
Q2189-X300 LTUCC SIPAC Compact shelf
Q2248-X LTUCW SIPAC Compact shelf
Q2261-X100 DSCX 80CXE / 40CMX
Q2266-X LTUCA 600 cPCI
Q2302-X NCUI SIPAC Compact shelf on
AP, 19" box on AP
Q2302-X10 NCUI SIPAC Compact shelf on
AP, 19" box on AP
Q2305-X NCUI2 SIPAC Compact shelf on
AP, 19" box on AP
Q2305-X10 NCUI2 SIPAC Compact shelf on
AP, 19" box on AP
The LTUCC board is not released in the moment and therefore all parameters which are used
to control the „central byte manipulation“ and „echo cancelation“ are not ieffective.
LTUC default value: Q2166-X.
41
EN4401EN00EN_0005
© 2005 Siemens AG
Administration: UCSU - Unit Configuration of Switching Unit Siemens
With parameter FRMTYPE the type of the LTU-shelf can be determined. The following table
gives an overview, which frametypes are allowed in which LTU of the different HICOM-types:
42
EN4401EN00EN_0005
© 2005 Siemens AG
Siemens Administration: UCSU - Unit Configuration of Switching Unit
Examples
1. Create LTU=1.
Input:
ADD-UCSU:LTU,1,1,,LTUW,LOCAL;
Output:
LTU 1.1 ADDED - IN OPERATION
Possible outputs:
LTU 1.1 ADDED - IN OPERATION
LTU 1.1 ADDED - OUT OF OPERATION
LTU 1.1 ADDED - OUT OF OPERATION (NOT PRESENT)
LTU 1.1 NOT ADDED
| |
| |
| +------ LTU
|
+-------- LTG
Output:
H01: LTU 1.1 ADDED - IN OPERATION (READY)
H02: LTU 1.2 ADDED - OUT OF OPERATION (DEF)
F14: LTU 1.3 ALREADY ADDED
F02: LTU 1.4 NOT ADDED (ORDER ERROR)
3. Create AP 20 (LTG 1)
Input:
ADD-UCSU:AP,1,20,"Q2302-X ",5,INCH19,APDL,,,234,"WILSHIRE BOULEVARD
123",6338234,6338236,30;
Output:
H15: PARAMETER APRTADDR CAN NOT BE CHECKED FOR A PLAUSIBLE VALUE.
THIS CHECK WILL BE DONE LATER WITHIN AMO-APRT.
H03: ADD DATA FOR LTU 1.20 WITH AMO CONSY
43
EN4401EN00EN_0005
© 2005 Siemens AG
Administration: UCSU - Unit Configuration of Switching Unit Siemens
6.1.2 CHANGE-UCSU
Modify by means of the action CHANGE:
– type of LTUC module and some other parameters of LTU
– PARTNO of central SIU
– Only the following LTUC/NCUI boards can be modified:
6.1.3 DELETE-UCSU
Examples
1. Delete LTU 2
Input:
DELETE-UCSU:UNIT=LTU,,2;
Output:
LTU 1.2 DELETED
LTU 1.2 NOT DELETED
| |
| +------ LTU no.
+-------- LTG no.
44
EN4401EN00EN_0005
© 2005 Siemens AG
Siemens Administration: UCSU - Unit Configuration of Switching Unit
Output:
H10: LTU 1.1 IS ALREADY DELETED
H07: LTU 1.2 DELETED
H07: LTU 1.3 DELETED
F07: LTU 1.4 NOT DELETED (ORDER ERROR)
6.1.4 DISPLAY-UCSU
The configuration and states of LTG and LTU can be determined by means of the action
DISPLAY.
Note
If the parameter LTG is not specified for UNIT=LTG, all LTGs are interrogated. In neither
parameter LTU nor parameter LTG is specified for UNIT=LTU, all LTUs are interrogated.
Examples
1. List all LTGs and LTUs. Overlay LTU 10 is assigned to standard LTU 3.
Input:
DISPLAY-UCSU:LTU;
Output:
+-----------+---------------------+-----------------------+------------+
| ADDRESS | EXPECTED CONFIGUR. | STATE OF A/B HALF | PARTNO SIU |
+-----------+---------------------+-----------------------+------------+
| LTG 1 | ADDED | READY / ? | Q2261-X |
+-----------+---------------------+-----------------------+------------+
+---------+-------------------+---------+--------------+----------+--------+
|ADDRESS |EXPECTED CONFIGUR. |STATE |LTUC MODULE |LTU-TYPE |FRMTYPE |
| +-------------------+---------+--------------+----------+--------+
| |CONNTYPE LOCATIONID LOCATION SRCGRP |
| |PHONE: FAX: |
| |AMOUNT VCOM CHIPS CHIPMODE1 CHIPMODE2 CHIPMODE3 CHIPMODE4 |
| | CHIPMODE5 CHIPMODE6 CHIPMODE7 CHIPMODE8 |
| |LOWER THRESHOLD HIGHER THRESHOLD RESERVED FOR AMC |
+---------+-------------------+---------+--------------+----------+--------+
45
EN4401EN00EN_0005
© 2005 Siemens AG
Administration: UCSU - Unit Configuration of Switching Unit Siemens
46
EN4401EN00EN_0005
© 2005 Siemens AG
Siemens Administration: UCSU - Unit Configuration of Switching Unit
2. List LTG 1.
Input:
DISPLAY-UCSU:LTG,1;
Output:
+-----------+---------------------+-----------------------+------------+
| ADDRESS | EXPECTED CONFIGUR. | STATE OF A/B HALF | PARTNO SIU |
+-----------+---------------------+-----------------------+------------+
| LTG 1 | ADDED | READY / READY | Q2234-X |
+-----------+---------------------+-----------------------+------------+
Only one status is output for the dependability and AM status, which may consist of a combi-
nation of statuses.
Possible outputs:
6.1.5 REGENERATE-UCSU
By means of this order, position-oriented commands for the regeneration of MBU, LTG or LTU
data are output.
Note
If parameter LTG is not specified for UNIT=LTG, regenerate commands are created for all
LTGs set up. If neither parameter LTU nor parameter LTG is specified for UNIT=LTU,
regenerate commands are created for all LTUs set up.
47
EN4401EN00EN_0005
© 2005 Siemens AG
Administration: USSU - Unit Switch of Switching Unit SWU Siemens
Example
1. Regenerate all
REGENERATE-UCSU;
Output:
REGENERATE-UCSU;
48
EN4401EN00EN_0005
© 2005 Siemens AG
Siemens Administration: USSU - Unit Switch of Switching Unit SWU
7.1.1 ACTIVATE-USSU
Activation of system units in the SWU.
1. Activating an LTU
2. Activating the LTG
3. Activating an central SIU
4. Activating an HDLC-DCL highway
5. Activating RTM board.
Activating an LTU involves removing the state "manual blocking". When an LTU is activated, all
hierarchically subordinate units are also unblocked by the CDC (Device Configuration, a part
of Dependability).
The system units are activated without testing.
Before it is activated, the state of the LTU is interrogated. If the LTU is in a state that does not
permit activation, the "activate" order is not issued, error message F22 is issued to the operator
and the AMO is terminated.
After the "activate" order has been executed, a message is output providing information about
the new switching state. No test is made after an LTU has been activated.
If an LTU is not specified, the LTG is activated.
Before activating the LTG, the AMO checks that it is configured. If it is configured, then the
presence of the LTG is reported to the operating system. Activating the LTG may take up to
several minutes. Thus, the AMO does not wait until the activation job is completed, but termi-
nates immediately issuing advisory message H13. The present loadingstate of the LTG is
displayed on DB-board.
When activating an central SIU, the AMO first sends a deactivation command which is immedi-
ately followed by the activation command. This ensures that the current circuit data is reloaded.
In the case of a duplex LTG, both central SIUs of the LTG are reloaded. In such cases, the
operator receives two advisories. Peripheral SIUs has to be switched by means of AMO BSSU.
Activating an HDLC-DCL highway may take up to several minutes. Thus, the AMO does not wait
until the activation job is completed, but terminates immediately issuing the advisory message
H25.
Activation of RTM board has two types : BOARD and DATA. BOARD type activation is handled
same as the SIU activation. The error and advisory messages ; F24, F25, F26 , H19 and H28
are used both for SIU and RTM activation.
For AP shelves (LTU from 17 to 99), there is a new mechanism. The AP shelf can not be
activated before the connection to the AP shelf is established via EXEC-USSU.
49
EN4401EN00EN_0005
© 2005 Siemens AG
Administration: USSU - Unit Switch of Switching Unit SWU Siemens
Examples:
Output:
H06: LTU ACTIVATED - NOT OPERATIONAL (NPR)
LTU3 of LTG1 has been manually unblocked. The module does not exist (NPR).Activate LTG1
Input:
ACTIVATE-USSU:LTG,1;
Output:
H13: LTG ACTIVATED
Output:
H06: LTU ACTIVATED - NOT OPERATIONAL (NPR)
LTU3 has been manually unblocked. The module does not exist (NPR).
3. Activate the SIU
Input:
ACTIVATE-USSU:SIU;
Output:
H28: SIU IN A-HALF WILL BE SWITCHED
H19: SIU ACTIVATED
H28: SIU IN B-HALF WILL BE SWITCHED
H19: SIU ACTIVATED
50
EN4401EN00EN_0005
© 2005 Siemens AG
Siemens Administration: USSU - Unit Switch of Switching Unit SWU
Output:
H25: HDLC-DCL HIGHWAY ACTIVATED
The HDLC highway is being activated though the process is not yet complete.
5. Activate LTU17
Input:
ACTIVATE-USSU:LTG,1,17;
F30: ACTIVATION OF THE AP SHELF NOT POSSIBLE.FIRST EXECUTE
’EXEC-USSU:CONFAP’.
6. Activate RTM
Input:
ACTIVATE-USSU:RTM,BOARD;
Output:
H28: RTM IN A-HALF WILL BE SWITCHED
H19: RTM ACTIVATED
H28: RTM IN B-HALF WILL BE SWITCHED
H19: RTM ACTIVATED
7.1.2 DEACTIVATE-USSU
Individual LTG or LTUs are deactivated. Deactivation involves setting of state "manual
blocking". When the LTG or an LTU is deactivated, all hierarchically subordinate units are also
deactivated by the CDC.
Before the LTG or an LTU is deactivated, its state is interrogated. If the LTG or LTU is in a state
which does not permit deactivation, no deactivation order is issued and the AMO is terminated
after issuing error message F22 to the operator. After the deactivation order has been success-
fully executed, the operator receives a positive acknowledgement.
For deactivating the LTG the AMO does not wait until the activation job is completed, but termi-
nates immediately issuing advisory message H26. The present loadingstate of LTG is
displayed on DB-board.
The AMO also checks whether the deactivation job involves the current reference clock
generator. If the current reference clock generator is on the LTG or LTU to be deactivated, and
other reference clock generators are present outside the specified LTG or LTU, the operator is
prompted for a value for the optional parameter REFOFF with advisory H22.
51
EN4401EN00EN_0005
© 2005 Siemens AG
Administration: USSU - Unit Switch of Switching Unit SWU Siemens
Message H23 is issued in the event the job affects all reference clock generators. In this case,
the user is also warned if the value Y was entered for parameter REFOFF.
The operator can specify what to do with regard to the reference clock by giving parameter
REFOFF the apropriate value. The value Y means that, if applicable, the LTG or LTU with the
current reference clock supply may be deactivated. The value N means that the LTU with the
current reference clock supply should not be deactivated. In this case, the AMO responds by
issuing advisory H24 or H27.
The value PROMPT for parameter REFOFF (the default value) means that, in the event the
current reference clock generator is within the specified LTU, the operator will be interrogated
as to whether or not the LTU should really be deactivated.
Examples:
Output:
H03: LTU DEACTIVATED
LTU3 of LTG1 was deactivated. Hierarchically subordinate modules were also deactivated.
2. Deactivate LTU1
Input:
DEACTIVATE-USSU:1,1;
Output:
F16: LTU NOT DEACTIVATED (ACTIVATION/DEACTIVATION IN PROGRESS)
LTU1 of LTG1 has not been deactivated, because an order for activation/deactivation of this
LTU is currently in progress.
52
EN4401EN00EN_0005
© 2005 Siemens AG
Siemens Administration: USSU - Unit Switch of Switching Unit SWU
7.1.3 DISPLAY-USSU
Background loading status of a specific LTU (valid only for AP shelves) is displayed. It also
provides :
● LTU number,
● Source group index,
● Name of the particular LW file or SIU tone files and
● load status
The masks corresponding to each control flag value are as follows :
FLAG MASK
LOAD_NULL NEVER LOADED
LOAD_STARTED STARTED
LOAD_IN_PROGRESS IN PROGRESS
LOAD_FINISHED FINISHED
LOAD_FAILED FAILED
Display mask looks like as follows :
+------------------------------------------------------------------------------+
| LTU: 1 SOURCE GROUP: 3 READY |
| LW FILE : XXXXXXXX FINISHED SIU TONES: XXXXXXXX FAILED |
| SIU RECV : XXXXXXXX IN PROGRESS SIU ANN : XXXXXXXX FAILED |
| SIU MOH : XXXXXXXX FAILED SIU TDS : XXXXXXXX NEVER LOADED|
+------------------------------------------------------------------------------+
53
EN4401EN00EN_0005
© 2005 Siemens AG
Administration: USSU - Unit Switch of Switching Unit SWU Siemens
54
EN4401EN00EN_0005
© 2005 Siemens AG
Siemens Administration: USSU - Unit Switch of Switching Unit SWU
LTG1 (PERIPHERY)
------
MOUNTING LOCATION MODULE NAME BDL BD(#=ACT) STATUS
------------------- LTG 1 --------------------- READY
-------L80XF------- LTU 2 --------------------- READY
P102.C80 1.L80 2.079 SLMO24 A Q2168-X READY
CCT LINE STNO SI BUS TYPE
001 136 OPTI ONLY READY
MULTLINE 8. . . . . . . . . . . . . . .READY
000 NO CONN
001 SUBUNIT . . . . . DIGITE MAIN READY
(OPTISET )
LINE: 179 STNO: 7441 SI: VOICE
001 . . . . . . . . DIGITE SUB A READY
002 . . . . . . . . DIGITE SUB A READY
003 . . . . . . . . DIGITE SUB C READY
002 NO CONN
003 NO CONN
004 NO CONN
005 NO CONN
006 NO CONN
007 NO CONN
008 NO CONN
AMO-SDSU -94 STATUS DISPLAY IN SWITCHING UNIT
DISPLAY COMPLETED;
55
EN4401EN00EN_0005
© 2005 Siemens AG
Administration: AMOs in the User Area Siemens
ZAND SXSU
SCSU / SBCSU STN
Exchange of
ZANDE Per STN No. personal and
STNNo.
Voice Terminals
device-related data
PERSI BERUZ
COSX SA
Personal time
identification controlled Hunt group
PIN / Name data
BERUM AUN
Call pick-up
CHESE COSX
group SSC
Exec./secretary manually
Secretary controlled Special Subscr.
system MESSENGER
Messen-
ger no.
56
EN4401EN00EN_0005
© 2005 Siemens AG
Siemens Administration: AMOs in the User Area
57
EN4401EN00EN_0005
© 2005 Siemens AG
Administration: Configuration of a subscriber Siemens
9 Configuration of a subscriber
PEN:
optional parameter, system is using the
next free PEN of a SLMO24/SLMOP, if the
parameter PEN isn’t used.
Related AMO: BCSU/SDSU
58
EN4401EN00EN_0005
© 2005 Siemens AG
Siemens Administration: Configuration of a subscriber
DPLN-group 0-15
Standard=0
Related AMO:
WABE
ITR-group 0-15
Standard=0
Related AMO:
COSX-group 0-15 VBZ
Standard=0
Related AMOs:
BERUM, BERUZ for switching
Secret station number
FEASU: COSXCD, COSXDB, COSXKEY, CO-
If “yes” is selected, the setting of the AMO
SXATND, COSXT
ZAND instead of PERSI is used.
WABE: DAR ACOSX/DCOSX
Related AMOs:
PERSI: PIN for COPIN 7 for the STN
ZAND: ALLDATA2, DISPNUUM=XXX
If ONLYEXT is selected, it is possible to trans-
mit an other number instead of the extension
number.
Related AMO:
KNMAT: MODCON=REPEXT
Central speed calling lists: 0-15
SPDC1: table 1
SPDC2: table 2 Speed Calling Individual
“16” code for deleting 0, 10, 20, 30 destinations
Related AMOs: Related AMOs:
LRNGZ, ZRNGZ DIMSU: SPDI
DIMSU: SPDCL, SPDCD FEASU: SPDI
FEASU: SPDC WABE: KZP=SPDI and SPDIPROG
WABE: DAR SPDC1, SPDC2 ZIEL
59
EN4401EN00EN_0005
© 2005 Siemens AG
Administration: Configuration of a subscriber Siemens
IDCR
Station with identity card reader
Station in service
yes/no or signed off (no PEN is used)
Alarmnumber
0: no alarm assigned
8-519: number of directional alarm group
520-583: number of personal alarm group
Related AMOs:
VADSU
Related AMOs:
FEASU: CBK, DCBB, DCBNOA
ZAND: ALLDATA, CBKNO
(number of callbacks for a STN activated in
case of busy or no answer)
60
EN4401EN00EN_0005
© 2005 Siemens AG
Siemens Administration: Configuration of a subscriber
Headset
WITHIND Headset with HW indication
NOIND: Headset ohne HW indication
Attention to parameter HSKEY in AMO SBCSU
Related AMOs:
FEASU: CBK, DCBB, DCBNOA
ZAND: ALLDATA, CBKNO
Related AMOs:
ZAND: ALLDATA2, TEXTSEL
In ACTIVE TEXTSEL up to 5 languages can be
selected.
An user should select the language with a key:
TAPRO: key LANSEL
SDAT: Attribute LNGDYN or LNGSTAT
61
EN4401EN00EN_0005
© 2005 Siemens AG
Administration: Configuration of a subscriber Siemens
62
EN4401EN00EN_0005
© 2005 Siemens AG
Siemens Administration: Deletion of a subscriber
10 Deletion of a subscriber
63
EN4401EN00EN_0005
© 2005 Siemens AG
Administration: Structure of the DPLN Siemens
Tabelle 1:
DPLN - General Part (valid for all dial plans)
DIS-WABE:GEN;
Here are listed all codes for those digit analysis results (DAR) which are
displays only the
to be accessible for all stations (valid for all dial plans).
general part!
All stations (DAR=STN) must be listed here.
64
EN4401EN00EN_0005
© 2005 Siemens AG
Siemens Administration: Structure of the DPLN
Tabelle 2:
65
EN4401EN00EN_0005
© 2005 Siemens AG
Administration: WABE - Digit Analysis Siemens
Associated digit analysis results are combined into a digit analysis result pair.
Add simultaneously
DAR 1 DAR 2
AFWDREM DFWDREM
AFWDDTE DFWDDTE
AFWDFAX DFWDFAX
AFFWDDTE DFFWDDTE
AFFWDFAX DFFWDFAX
AFFWDVCE DFFWDVCE
ACBK DCBK
AHTDTE DHTDTE
AHTFAX DHTFAX
AHTVCE DHTVCE
AREM DREM
VMOWN VMFOR
MBON MBOFF
Digit analysis result pairs
66
EN4401EN00EN_0005
© 2005 Siemens AG
Siemens Administration: WABE - Digit Analysis
12.1 ADD-WABE
With this command it is possible to create 1 DAR for one or more CDs or several DARs for one
CD.
In the case of digit analysis result pairs, it is possible to assign both partners for the same sta-
tion number if the desired call progress states are completely mutually exclusive.
If parameter DPLN is omitted, the DAR is created without DPLN branching for all DPLN groups.
If CHECK is not specified, CHECK=ALL is taken as default value.
Example
1. Assign the DAR=STN (station) to station numbers 3200-3299 for all call progress states
allowed for STN.
Input:
ADD-WABE:CD=3200&&3299,DAR=STN;
12.2 DISPLAY-WABE
This function allows the user to
1. display the contents of the DPLN tables according to various criteria (TYPE=GEN).
2. display STN seizures throughout the network based on the destination numbers
(TYPE=STN) or the destination node numbers (TYPE=DNNO).
3. output all CPS values valid for specific DARs (TYPE=CPS).
4. view the office codes currently assigned to the ARNs (TYPE=ARN). This display reflects
the current data stored in the ARN to office code assignment table for digit code display.
In the TYPE=GEN branch, all dial plan data is listed in a table, that is valid independent of
DPLN groups. This is followed by the specific tables for the individual DPLN groups. These ta-
bles show the CDs and CPSs for which a DAR is set up. To obtain a complete output (indepen-
dent of DPLN groups and all DPLN group specific), enter the parameter DPLN=0&&15. If no
value is entered for the parameter DPLN, then the table with the DPLN-independent entries is
only output.
The column for additional information (RESERVED and so on) shows which route DARs are
predefined in the dial plan and are not otherwise used in the system. This is shown by the value
’R’. The same information is output for DAR=STN. If dialed number conversion is assigned to
a station, then this will be shown by the value ’C’ in this column (It is assigned by the AMO RU-
FUM). If a station is assigned as destination for DNI by ACD, then this will be shown by the value
67
EN4401EN00EN_0005
© 2005 Siemens AG
Administration: WABE - Digit Analysis Siemens
’D’ in this column (It is assigned by the AMO DNIT). The output of an ARN assigned to a CD
of DAR OWNNODE in the dial plan is done also in this column as well as the output of a DEST-
NO and DNNO assigned to a CD of DAR STN, NETW, NETRTE.
Apart from the parameter TYPE, all parameters are optional. If parameters are not explicitly de-
clared, the inputs are initialized with the maximum permitted range in most cases. The default
range for the parameter DESTNO is the entire possible range (0...254); the default value for
DAR is ALL. The exception is parameter DPLN, which must be specified if any DPLN group
specific data should be output.
In the DISPLAY command with TYPE=GEN, a range for the parameter CD may be specified
both, with special characters and different length.
Examples
1. Display the DPLN data with the DAR=ADND
Input:
DISPLAY-WABE:DAR=ADND;
Output:
------------------------------------------------------------------------------
| DIGIT INTERPRETATION VALID FOR ALL DIAL PLANS |
------------------------------------------------------------------------------
| | CALL PROGRESS STATE | DIGIT | RESERVED/CONVERT |
| STATION NUMBER | 1 11111 11112 22| ANALYSIS | DNI/ADD-INFO |
| |0 12345 67890 12345 67890 12| RESULT | *=OWN NODE |
------------------------------------------------------------------------------
| 812 |. ....* ..... ..... ..... ..| ADND | |
| *12 |. ....* ..... ..... ..... ..| ADND | |
------------------------------------------------------------------------------
68
EN4401EN00EN_0005
© 2005 Siemens AG
Siemens Administration: WABE - Digit Analysis
69
EN4401EN00EN_0005
© 2005 Siemens AG
Administration: WABE - Digit Analysis Siemens
70
EN4401EN00EN_0005
© 2005 Siemens AG
Siemens Administration: WABE - Digit Analysis
12.3 REGENERATE-WABE
REGENERATE is similar to DISPLAY. First the commands are output which are valid for all
DPLN (DLN group independent), followed by those that are valid for individual DPLN groups.
All commands are output with CHECK=N.
The DARs STN always are treated as internal reserved stations. After the last ADD command
is output, external stations are searched and the CHANGE commands are output for increasing
order of station numbers.
The DARs OWNNODE are always displayed with the actual ARNs, stored in the dial plan. To
rebuild the ARN to office code assignment table for digit code display, the CHANGE commands
of TYPE=ARN are created after the last ADD command is output.
For the parameters of the REGENERATE command please refer the notes for the parameters
of action DISPLAY / TYPE=GEN.
Example:
Regenerate the DPLN group 2
Input:
REG-WABE:DPLN=2;
Output:
ADD-WABE: 0 , , 9, ANSINT , N,,,,, , ;
ADD-WABE: 00 , , 2, SPDC1 , N,,,,, , ;
ADD-WABE: 00 , , 3, SPDC1 , N,,,,, , ;
ADD-WABE: 20 , , 2, SPDC2 , N,,,,, , ;
ADD-WABE: 28 , , 5, HUNT , N,,,,, , ;
ADD-WABE: 3111 , , , ATNDDID , N,,,,, , ;
ADD-WABE: 3112 &&3199 , , 6, STN , N,,,,, , ;
ADD-WABE: 401 , , 10, ATNDIND , N,,,,, , ;
ADD-WABE: 722 , , 5, AFWDDTE , N,,,,, , ;
ADD-WABE: 726 , , 5, DFWDDTE , N,,,,, , ;
ADD-WABE: DD8 , , , NETRTE , N,,,,, , ;
ADD-WABE: 21011 , 2, 5, TIEATND , N,,,,, , ;
ADD-WABE: 401 , 2, , CONF3 , N,,,,, , ;
ADD-WABE: 401 , 2, 8, PRESCONF, N,,,,, , ;
ADD-WABE: 500 , 2, , CCMANS , N,,,,, , ;
ADD-WABE: 51 , 2, 9, CCMS , N,,,,, , ;
ADD-WABE: 50 , 2, 16, CCMSURG , N,,,,, , ;
ADD-WABE: 70* , 2, , VMOWN , N,,,,, , ;
ADD-WABE: 70# , 2, , VMFOR , N,,,,, , ;
ADD-WABE: 7A , 2, , NETW , N,,,,, 213, ;
CHANGE-WABE: 3127 &&3136 , 172;
CHANGE-WABE: 3137 &&3139 , 11;
71
EN4401EN00EN_0005
© 2005 Siemens AG
Administration: COSSU - Classes of Service Siemens
13.1 ADD-COSSU
A COS can be added in several different ways:
1. Add a new COS while specifying the COS number
ADD-COSSU:NEWCOS=.., .. plus the selected authorizations
2. Add a new COS by copying an existing COS and changing the contents
a) Specify the number of the new COS
ADD-COSSU:COPYCOS=..,NEWCOS=.., .. plus the desired changes
b) The new COS can have any number (1 - 1000)
ADD-COSSU:COPYCOS=.., plus the desired changes
72
EN4401EN00EN_0005
© 2005 Siemens AG
Siemens Administration: COSSU - Classes of Service
3. Add a new COS without specifying the COS number and without specifying a COS to be
copied. Only the selected authorizations are specified.
a) If an identical class of service exists, a new COS is not added. The number of the iden-
tical COS is returned.
b) If an identical class of service does not exist, a new COS is added with the specified
authorizations.
4. Add an “empty” COS.
ADD-COSSU:;
In each case, the number of the COS added is output with an advisory message.
The authorizations are inserted by means of the parameters AVCE, AFAX, ADTE or deleted by
means of the parameters DVCE, DFAX, DDTE.
Examples
1. Add a new COS (see item 3.) with the voice authorizations TA, HOT, CDRS, TRACE and
the fax authorization BASIC.
Input:
ADD-COSSU:AVCE=RTA1&RTA6&HOT&CDRS&TRACE,AFAX=BASIC;
Output:
H04: THE NUMBER OF THE CLASS OF SERVICE ADDED IS 27.
2. Add a COS by copying COS 23 (see item 2b.) and inserting the new authorization CDRS.
Input:
ADD-COSSU:COPYCOS=13,AVCE=CDRS;
Output:
H04: THE NUMBER OF THE CLASS OF SERVICE ADDED IS 28.
3. Add COS 30 by copying COS 1 and assigning the external class of service COEX 5 (see
item 2a.)
Input:
ADD-COSSU:COPYCOS=1,NEWCOS=30,COEX=5;
Output:
H04: THE NUMBER OF THE CLASS OF SERVICE ADDED IS 30.
73
EN4401EN00EN_0005
© 2005 Siemens AG
Administration: COSSU - Classes of Service Siemens
13.2 CHANGE-COSSU
If a COS is changed, the change affects all the stations or trunk circuits to which this COS is
assigned. You can display this assignment by means of the AMOs ACSU, SCSU/SBCSU and
TACSU.
Example
1. Change authorizations in COS 16.
(delete BASIC for FAX, insert RTA3 for voice)
CHANGE-COSSU:TYPE=COS,COS=16,AVCE=RTA3,DFAX=BASIC;
13.3 DELETE-COSSU
Classes of service can be deleted provided that they are not used by any stations or trunk cir-
cuits.
Example
Delete COS 27.
DELETE-COSSU:COS=27;
13.4 DISPLAY-COSSU
1. Output all classes of service.
All the configured classes of service, the 16 COEX (even if not assigned to a COS) and all
the LCR classes of services are output.
2. Selectively output one or more COS.
3. Output the COS containing the specified authorizations (TYPE = COS ).
4. Output the external classes of service (COEX).
5. You can display all the LCR classes of service for voice (TYP=LCOSV parameter only) or
all the LCR classes of service for data (TYP=LCOSD parameter only) along with their LCR
authorizations and options.
You can display specific LCR classes of service for voice (TYPE=LCOSV plus LCOSV pa-
rameter) or specific LCR classes of service for data (TYP=LCOSD plus LCOSD parame-
ter) along with their LCR authorizations and options.
6. However, you can also display the numbers of the LCR classes of service containing at
least one of maximum five predefined LCR authorizations (TYPE=LCOS and LCOS pa-
rameter).
74
EN4401EN00EN_0005
© 2005 Siemens AG
Siemens Administration: COSSU - Classes of Service
7. Finally, you can also output the station numbers of all the stations and the port equipment
numbers of all the circuits (by specifying the associated AMO for each) to which a specific
COS or a specific LCOSV/D is assigned (TYPE=COS with FORMAT=REF or
TYPE=LCOSV/D with FORMAT=REF).
Examples
1. Display COS 1 and 3 to 5
DISPLAY-COSSU:TYPE=COS,COS=1&3&&5;
Output:
+-----+----------------+----------------+----------------+
| COS | VOICE | FAX | DTE |
+-----+----------------+----------------+----------------+
| 1 |>EXAMPLE 1 |
| | RTA1 | RTA1 | RTA1 |
| | RTA4 | RTA4 | RTA4 |
| 3 |>EXAMPLE 3 |
| | RTA3 | NOTIE | NOTIE |
| | RTA4 | RTA4 | RTA4 |
| 4 |> |
| | RTA | NOTIE | NOTIE |
| | TTCR3 | RTA | RTA |
| | TTCR4 | BASIC | BASIC |
| | COSXCD | | |
| | COEX1 | | |
| | | | |
+-----+----------------+----------------+----------------+
Only COS 1, 3 and 4 are configured. In this case, no INFOTEXT is configured for COS 4.
2. Display the COS containing the specified authorization pattern.
DISPLAY-COSSU:TYPE=AUTH,COND=SUBSET,VCE=RTA&RTA1&RTA2&TTCR1&TTCR2;
(Note: COND=SUBSET parameter does not have to be specified because the value
of SUBSET is assumed to be the DEFAULT value.)
Output:
+------------------------------------------------------+
| THE CLASS MARKS ARE CONTAINED IN THE FOLLOWING COS |
+----------+----------+----------+----------+----------+
| COS 24 | COS 25 | | | |
+----------+----------+----------+----------+----------+
75
EN4401EN00EN_0005
© 2005 Siemens AG
Administration: COSSU - Classes of Service Siemens
3. OUTPUT LCOSS 2 TO 5
Input:
DISPLAY-COSSU:TYPE=LCOSV,LCOSV=2&&5;
Output:
+----+----------------------------------------------------------------+-----+
|LCOS| LAUTH | LCR |
| V | 1 2 3 4 5 6 |OPTS=|
| |1234567890123456789012345678901234567890123456789012345678901234|LCRET|
| |>SERVICE INFORMATION | LCR |
+----+----+----|----+----|----+----|----+----|----+----|----+----|----+-----+
| 2|XX..............................................................| . |
| 3|XX..............................................................| . |
| 4|.............X......................X...........................| X |
| 5|................................................................| . |
+----+----------------------------------------------------------------+-----+
+-----+-----------------------------------------------------------------+
| LCOS| LCOSV | LCOSD |
| | 1 2 3 | 1 2 3 |
| |12345678901234567890123456789012|12345678901234567890123456789012|
| |>SERVICE INFORMATION |
+-----+----+----|----+----|----+----|--+----+----|----+----|----+----|--+
| 4 |XXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXX|X |
| 8 |XXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXX|X |
+---- +-----------------------------------------------------------------+
76
EN4401EN00EN_0005
© 2005 Siemens AG
Siemens Administration: COSSU - Classes of Service
13.5 REGENERATE-COSSU
If no parameter is entered, all the COS, COEX and LCR COS are regenerated.
1. Regenerate all configured classes of service (TYPE=COS only) or the specified COS (in
addition to TYPE=COS, also COS=<number>).
The regenerated COS is distributed over several commands (one command per service). If
a COS is assigned to a COEX, a CHANGE command with TYPE=COEX is also generated.
2. Regenerate external classes of service (COEX) only.
3. You can regenerate all the LCR classes of service for voice (TYPE=LCOSV parameter on-
ly) or all the LCR classes of service for data (TYPE=LCOSD parameter only) along with
their LCR authorizations and LCR options. You can regenerate specific LCR classes of
service along with their LCR authorizations and LCR options (TYPE=LCOSV/D plus
LCOSV/D parameter).
Examples
1. Regenerate class of service 16
INPUT:
REGERATE-COSSU:COS=16;
OUTPUT:
ADD-COSSU:,16,TA&TNOTCR&CDRATN&CDRSTN&CDRINT,,,,,,,,,,,;
77
EN4401EN00EN_0005
© 2005 Siemens AG
Administration: TAPRO - Key Programming Siemens
Functions
The AMO TAPRO can be used for the following terminal types:
● optiset E T3 / T8 / T12
● optipoint 500 T8 / T12 / T19
● optipoint 600 T19
● optiPoint 400 T12
● optiPoint 410 T8 / T12 / T19
● optiPoint 420 T12 / T18
● as well as the various add-on terminal types for optiset E and optipoint 500/600/410/420.
With the AMO TAPRO, it is not necessary to set up the standard key assignments, since all 127
for optiset valid standard assignments for each terminal type are already stored in the data-
base. All terminals are allocated one of these standard assignments when they are first config-
ured.
14.1 CHANGE-TAPRO
Change the standard key layout or change the freely-programmable key layout for one or more
stations.
The changes are carried out as follows:
● Changing a standard key layout.
For this, the number of the standard key layout must be specified instead of a station num-
ber. Changing a standard key layout has no direct effect on the key layouts already loaded
at the various terminals.
Hints for changing the standard key layouts:
– Max. 4 RNGXFER keys and max. 4 PUS keys.
78
EN4401EN00EN_0005
© 2005 Siemens AG
Siemens Administration: TAPRO - Key Programming
– The remaining functions (except VACANT, LINE, NAME and DSS) may only be as-
signed once. When allocating an existing key function to a different key during a stand-
ard key layout change, the old key allocation is canceled automatically.
● Assigning the key functions
For this, at least one station number must be specified. If a standard key layout number is
also specified, a standard key layout is assigned. If no standard key layout is specified, the
AMO assumes that only the functions of the freely-programmable keys are to be loaded.
Only one command is necessary to change the standard key layout and assign new func-
tions to the freely-programmable keys of the specified station(s).
Hints for assigning the key functions
– Max. 4 RNGXFER keys (execpt subscriber is executive) and max. 4 PUS keys.
– Max. 1 RNGXFER key if subscriber is executive
A standard with more than 1 RNGXFER key can be assigned to a executive, but the
executive can only use the first RNGXFER key and the others are only allocated with
this function. If one RNGXFER key is indiviual changed, all other RNGXFER keys are
deleted.
– The remaining functions (except VACANT, LINE, NAME and DSS) may only be as-
signed once. When allocating an existing key function to a different key during a stand-
ard key layout change, the old key allocation is canceled automatically.
– The MB key function cannot be re-assigned if the user’s "mailbox" contains new (i.e.
unheard) messages.
– The following keys must not be deleted while in the active state:
FWD key, REP key, KNOVR key, DND key and HT key.
Note
The terminal will be not deactivated from the AMO TAPRO, exeption deletion of DSS keys.
If the terminal was deactivated befor the processing, it remain deactivated.
A standard key layout with add-on terminal can be assigned to a subscriber OPTISET without
add-on terminal, but only the key functions of the basic terminal are accepted.
Examples
1. Change the standard key layout 5 for all optiset terminals. Change KY01 to call forwarding
and KY02 - KY04 to name keys.
Input:
CHANGE-TAPRO:STD=5,DIGTYP=OPTISET,KY01=FWD,KY02=NAME,KY03=NAME,KY04=NAME;
79
EN4401EN00EN_0005
© 2005 Siemens AG
Administration: TAPRO - Key Programming Siemens
Output:
H04: STANDARD 5 CHANGED FOR OPTISET.
2. Load the new standard 5 at the optiset terminal of station 3154, and change the function
of key 12 to TIME.
Input:
CHANGE-TAPRO:STNO=3154,STD=5,DIGTYP=OPTISET,KY12=TIME;
Output:
H03: FUNCTION KEY LAYOUT CHANGED FOR STATION 3154.
14.2 DISPLAY-TAPRO
This function is used to output the following information:
1. all valid standard key layouts and all loaded key layouts for all stations with digital terminals.
2. specific standard key layouts in a specific output format. Patternsearch in info service field.
3. key layouts loaded at specific stations.
Examples
1. Display the key layout of standard 7 and standards 38 to 40 for optiset.
Input:
DISPLAY-TAPRO:TYPE=STD,STD=7&38&&40,DIGTYP=OPTISET;
Output:
+-----+---------+--------------------------------------------------------------+
| STD | DIGTYP | "SERVICE INFORMATION’ KEY LAYOUT |
+-----+---------+--------------------------------------------------------------+
| 7 | OPTIT3 | "3 KEYS U.S. STD 3: HOLD/PARK (SYSTEM ORBIT) " |
| | | 1 HOLD 2 SPARK 3 LINE |
| + - - - - + - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -+
| | OPTIA1 | 1 VACANT 2 VACANT 3 VACANT 4 VACANT 5 VACANT |
| | | 6 VACANT 7 VACANT 8 VACANT 9 VACANT 10 VACANT |
| | | 11 VACANT 12 VACANT 13 VACANT 14 VACANT 15 VACANT |
| + - - - - + - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -+
| | OPTIA2 | 1 VACANT 2 VACANT 3 VACANT 4 VACANT 5 VACANT |
| | | 6 VACANT 7 VACANT 8 VACANT 9 VACANT 10 VACANT |
| | | 11 VACANT 12 VACANT 13 VACANT 14 VACANT 15 VACANT |
| + - - - - + - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -+
| | OPTIA3 | 1 VACANT 2 VACANT 3 VACANT 4 VACANT 5 VACANT |
| | | 6 VACANT 7 VACANT 8 VACANT 9 VACANT 10 VACANT |
| | | 11 VACANT 12 VACANT 13 VACANT 14 VACANT 15 VACANT |
80
EN4401EN00EN_0005
© 2005 Siemens AG
Siemens Administration: TAPRO - Key Programming
| + - - - - + - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -+
| | OPTIA4 | 1 VACANT 2 VACANT 3 VACANT 4 VACANT 5 VACANT |
| | | 6 VACANT 7 VACANT 8 VACANT 9 VACANT 10 VACANT |
| | | 11 VACANT 12 VACANT 13 VACANT 14 VACANT 15 VACANT |
+-----+---------+--------------------------------------------------------------+
| 38 | OPTIT19 | "19 KEYS I.M. STD 6: ADVANCED KEY 5 LINES " |
| | | 1 CH 2 SNR 3 MB 4 SPKR 5 PU |
| | | 6 PARK 7 HOLD 8 LINE 9 LINE 10 LINE |
| | | 11 LINE 12 LINE 13 NAME 14 NAME 15 NAME |
| | | 16 NAME 17 NAME 18 NAME 19 RLS |
| + - - - - + - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -+
| | OPTIA1 | 1 VACANT 2 VACANT 3 VACANT 4 VACANT 5 VACANT |
| | | 6 VACANT 7 VACANT 8 VACANT 9 VACANT 10 VACANT |
| | | 11 VACANT 12 VACANT 13 VACANT 14 VACANT 15 VACANT |
| + - - - - + - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -+
| | OPTIA2 | 1 VACANT 2 VACANT 3 VACANT 4 VACANT 5 VACANT |
| | | 6 VACANT 7 VACANT 8 VACANT 9 VACANT 10 VACANT |
| | | 11 VACANT 12 VACANT 13 VACANT 14 VACANT 15 VACANT |
| + - - - - + - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -+
| | OPTIA3 | 1 VACANT 2 VACANT 3 VACANT 4 VACANT 5 VACANT |
| | | 6 VACANT 7 VACANT 8 VACANT 9 VACANT 10 VACANT |
| | | 11 VACANT 12 VACANT 13 VACANT 14 VACANT 15 VACANT |
| + - - - - + - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -+
| | OPTIA4 | 1 VACANT 2 VACANT 3 VACANT 4 VACANT 5 VACANT |
| | | 6 VACANT 7 VACANT 8 VACANT 9 VACANT 10 VACANT |
| | | 11 VACANT 12 VACANT 13 VACANT 14 VACANT 15 VACANT |
+-----+---------+--------------------------------------------------------------+
| 39 | OPTIT19 | "19 KEYS U.S. STD 0: 2 LINE PHONEMAIL " |
| | | 1 PHML 2 NAME 3 CH 4 MENU 5 CL |
| | | 6 NAME 7 NAME 8 NAME 9 NAME 10 NAME |
| | | 11 NAME 12 PU 13 PARK 14 CONF 15 CONS |
| | | 16 CNCT 17 HOLD 18 LINE 19 LINE |
| + - - - - + - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -+
| | OPTIA1 | 1 VACANT 2 VACANT 3 VACANT 4 VACANT 5 VACANT |
| | | 6 VACANT 7 VACANT 8 VACANT 9 VACANT 10 VACANT |
| | | 11 VACANT 12 VACANT 13 VACANT 14 VACANT 15 VACANT |
| + - - - - + - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -+
| | OPTIA2 | 1 VACANT 2 VACANT 3 VACANT 4 VACANT 5 VACANT |
| | | 6 VACANT 7 VACANT 8 VACANT 9 VACANT 10 VACANT |
| | | 11 VACANT 12 VACANT 13 VACANT 14 VACANT 15 VACANT |
| + - - - - + - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -+
| | OPTIA3 | 1 VACANT 2 VACANT 3 VACANT 4 VACANT 5 VACANT |
| | | 6 VACANT 7 VACANT 8 VACANT 9 VACANT 10 VACANT |
| | | 11 VACANT 12 VACANT 13 VACANT 14 VACANT 15 VACANT |
| + - - - - + - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -+
| | OPTIA4 | 1 VACANT 2 VACANT 3 VACANT 4 VACANT 5 VACANT |
| | | 6 VACANT 7 VACANT 8 VACANT 9 VACANT 10 VACANT |
| | | 11 VACANT 12 VACANT 13 VACANT 14 VACANT 15 VACANT |
+-----+---------+--------------------------------------------------------------+
| 40 | OPTIT19 | "19 KEYS U.S. STD 1: ACD AGENT " |
| | | 1 PHML 2 SCROL 3 CH 4 MENU 5 CL |
| | | 6 ACDLOG 7 ACDNAV 8 ACDWORK 9 ACDAV 10 ACDSPVM |
81
EN4401EN00EN_0005
© 2005 Siemens AG
Administration: TAPRO - Key Programming Siemens
Output:
+--------------+-----+---------+----------------------------------------------+
| STATION | STD | DIGTYP | FUNCTION KEYS WHICH DIFFER FROM STANDARD |
+--------------+-----+---------+----------------------------------------------+
| 2190 | 0 | OPTISET | 4 VACANT 10 DOOR 11 SPKR |
+--------------+-----+---------+----------------------------------------------+
| 2191 | 1 | OPTISET | 1 MB 2 ST 3 SNR 5 VACANT |
+--------------+-----+---------+----------------------------------------------+
| 2193 | 1 | OPTISET | 2 CONS 8 MB |
| | + - - - - + - - - - - - - - - - - - - - - - - - - - - - -+
| | | OPTIA1 | 12 WW |
+--------------+-----+---------+----------------------------------------------+
| 2194 | 1 | OPTISET | 2 CONS 8 MB |
| | + - - - - + - - - - - - - - - - - - - - - - - - - - - - -+
| | | OPTIA2 | 9 DR |
| | + - - - - + - - - - - - - - - - - - - - - - - - - - - - -+
| | | OPTIA4 | 8 DOOR 12 SNR |
+--------------+-----+---------+----------------------------------------------+
The key layout is displayed for all terminals whose station numbers lie within the specified range
of 2190 to 2191, regardless of the terminal type.
82
EN4401EN00EN_0005
© 2005 Siemens AG
Siemens Administration: TAPRO - Key Programming
3. Display the key layout for all stations with optiset terminals and the standard key layout 0.
Input:
DISPLAY-TAPRO:TYPE=STN,STD=0,DIGTYP=OPTISET;
Output:
+--------------+-----+---------+--------------------------------------------+
| STATION | STD | DIGTYP | FUNCTION KEYS WHICH DIFFER FROM STANDARD |
+--------------+-----+---------+--------------------------------------------+
| 2191 | 0 | OPTISET | 1 MB 2 ST 3 SNR 5 VACANT |
+--------------+-----+---------+--------------------------------------------+
| 3500 | 0 | OPTISET | |
| | + - - - - + - - - - - - - - - - - - - - - - - - - - - -+
| | | OPTIA2 | 1 RR |
+--------------+-----+---------+--------------------------------------------+
All digital optiset terminals with the specified standard key layout are output according to station
number.
4. Display service Informations for key standards 0.
Input:
DISPLAY-TAPRO:TYPE=STD,STD=0,FORMAT=S,INFOPAT="12 KEYS";
Output:
+-----+---------+--------------------------------------------------------------+
| STD | DIGTYP | "SERVICE INFORMATION' KEY LAYOUT |
+-----+---------+--------------------------------------------------------------+
| 8 | OPTIT12 | "12 KEYS I.M. STD 0: BASIC12 /SPEAKER12 " |
+-----+---------+--------------------------------------------------------------+
| 9 | OPTIT12 | "12 KEYS I.M. STD 1: BASIC12 /SPEAKER12 ALTERNATIVE" |
+-----+---------+--------------------------------------------------------------+
| 10 | OPTIT12 | "12 KEYS I.M. STD 2: 4 PERSON TEAM " |
+-----+---------+--------------------------------------------------------------+
| 11 | OPTIT12 | "12 KEYS I.M. STD 3: 8 PERSON TEAM (1 KEU) " |
+-----+---------+--------------------------------------------------------------+
| 12 | OPTIT12 | "12 KEYS I.M. STD 4: SECRETARY 1/1 (1 KEU) " |
+-----+---------+--------------------------------------------------------------+
| 13 | OPTIT12 | "12 KEYS I.M. STD 5: SECRETARY 1/2 OR 2/2 (1 KEU) " |
+-----+---------+--------------------------------------------------------------+
| 14 | OPTIT12 | "12 KEYS I.M. STD 6: SECRETARY 4/1 OR 4/2 (1 KEU) " |
+-----+---------+--------------------------------------------------------------+
| 15 | OPTIT12 | "12 KEYS I.M. STD 7: SECRETARY MEMBER OF MINI CHESE" |
+-----+---------+--------------------------------------------------------------+
| 16 | OPTIT12 | "12 KEYS I.M. STD 8: EXECUTIVE MEMBER OF MINI CHESE" |
+-----+---------+--------------------------------------------------------------+
| 17 | OPTIT12 | "12 KEYS I.M. STD 9: ACD AGENT 1 " |
+-----+---------+--------------------------------------------------------------+
| 18 | OPTIT12 | "12 KEYS I.M. STD 10: ACD SUPERVISOR 1 " |
83
EN4401EN00EN_0005
© 2005 Siemens AG
Administration: TAPRO - Key Programming Siemens
+-----+---------+--------------------------------------------------------------+
| 19 | OPTIT12 | "12 KEYS I.M. STD 11: ACD AGENT 2 " |
+-----+---------+--------------------------------------------------------------+
| 20 | OPTIT12 | "12 KEYS I.M. STD 12: ACD SUPERVISOR (1 KEU) " |
+-----+---------+--------------------------------------------------------------+
| 21 | OPTIT12 | "12 KEYS I.M. STD 13: BASIC12 /SPEAKER12 KEY STD " |
+-----+---------+--------------------------------------------------------------+
| 22 | OPTIT12 | "12 KEYS I.M. STD 14: ADVANCED KEY 4 LINES " |
+-----+---------+--------------------------------------------------------------+
| 23 | OPTIT12 | "12 KEYS I.M. STD 15: ADVANCED KEY (1 KEU) " |
+-----+---------+--------------------------------------------------------------+
| 24 | OPTIT12 | "12 KEYS I.M. STD 16: ADVANCED KEY (2 KEU) " |
+-----+---------+--------------------------------------------------------------+
| 25 | OPTIT12 | "12 KEYS I.M. STD 17: BASIC KEY AGENT " |
+-----+---------+--------------------------------------------------------------+
| 26 | OPTIT12 | "12 KEYS I.M. STD 18: BASIC KEY SUPERVISOR (1 KEU) " |
+-----+---------+--------------------------------------------------------------+
| 27 | OPTIT12 | "12 KEYS I.M. STD 19: ADVANCED KEY AGENT (1 KEU) " |
+-----+---------+--------------------------------------------------------------+
| 28 | OPTIT12 | "12 KEYS I.M. STD 20: ADV. KEY SUPERVISOR (1 KEU) " |
+-----+---------+--------------------------------------------------------------+
| 96 | OPTIT12 | "12 KEYS U.S. STD 0: 1 LINE PHONEMAIL " |
+-----+---------+--------------------------------------------------------------+
| 97 | OPTIT12 | "12 KEYS U.S. STD 1: 1 LINE PHONEMAIL PICKUP " |
+-----+---------+--------------------------------------------------------------+
| 98 | OPTIT12 | "12 KEYS U.S. STD 2: 2 LINE MB " |
+-----+---------+--------------------------------------------------------------+
| 99 | OPTIT12 | "12 KEYS U.S. STD 3: 2 LINE ACD AGENT PHONEMAIL " |
+-----+---------+--------------------------------------------------------------+
| 100 | OPTIT12 | "12 KEYS U.S. STD 4: 2 LINE ACD SUPERVISOR " |
+-----+---------+--------------------------------------------------------------+
| 101 | OPTIT12 | "12 KEYS U.S. STD 5: 1 LINE DDS " |
+-----+---------+--------------------------------------------------------------+
| 102 | OPTIT12 | "12 KEYS U.S. STD 6: 2 LINE INTERCOM " |
+-----+---------+--------------------------------------------------------------+
| 103 | OPTIT12 | "12 KEYS U.S. STD 7: 3 LINE PHONEMAIL " |
+-----+---------+--------------------------------------------------------------+
| 104 | OPTIT12 | "12 KEYS U.S. STD 8: 1 LINE PHML (1 KEU: DDS) " |
+-----+---------+--------------------------------------------------------------+
| 105 | OPTIT12 | "12 KEYS U.S. STD 9: 1 LINE PHML (1 KEU: EXECUTIVE)" |
+-----+---------+--------------------------------------------------------------+
| 106 | OPTIT12 | "12 KEYS U.S. STD 10: 1 LINE PHML (1 KEU: LINES) " |
+-----+---------+--------------------------------------------------------------+
| 107 | OPTIT12 | "12 KEYS U.S. STD 11: ACD SUPERVISOR (KEU) " |
+-----+---------+--------------------------------------------------------------+
| 108 | OPTIT12 | "12 KEYS U.S. STD 11: ACD SUPERVISOR (KEU) " |
+-----+---------+--------------------------------------------------------------+
84
EN4401EN00EN_0005
© 2005 Siemens AG
Siemens Administration: TAPRO - Key Programming
14.3 REGENERATE-TAPRO
This function is used to output a command batch with the following information:
1. all valid standard key layouts and all loaded key layouts for all stations with digital terminals.
2. specific standard key layouts.
3. key layouts loaded at specific stations.
For 1 and 3, the parameters are only output for those terminals whose key function alloca-
tion differs from the standard key layout.
Example
1. Regenerate standard key layout 0 for optiset.
Input:
REGENERATE-TAPRO:TYPE=STD,STD=0,DIGTYP=OPTISET;
Output:
CHANGE-TAPRO:,0,OPTIT8,MB,ST,RLS,FWD,CDK,SNR,CONS,SPKR,,,,,,,,,,,,"8 KEYS I.M. STD
0: ENTRY 8";
CHANGE-
TAPRO:,0,OPTIA1,VACANT,VACANT,VACANT,VACANT,VACANT,VACANT,VACANT,VACANT,VACANT,VAC
ANT,VACANT,VACANT,VACANT,VACANT,VACANT,,,,,;
CHANGE-
TAPRO:,0,OPTIA2,VACANT,VACANT,VACANT,VACANT,VACANT,VACANT,VACANT,VACANT,VACANT,VAC
ANT,VACANT,VACANT,VACANT,VACANT,VACANT,,,,,;
CHANGE-
TAPRO:,0,OPTIA3,VACANT,VACANT,VACANT,VACANT,VACANT,VACANT,VACANT,VACANT,VACANT,VAC
ANT,VACANT,VACANT,VACANT,VACANT,VACANT,,,,,;
CHANGE-
TAPRO:,0,OPTIA4,VACANT,VACANT,VACANT,VACANT,VACANT,VACANT,VACANT,VACANT,VACANT,VAC
ANT,VACANT,VACANT,VACANT,VACANT,VACANT,,,,,;
2. Regenerate the functions which differ from standard for stations 3154 to 3200.
Input:
REGENERATE-TAPRO:TYPE=STN,STNO=3154&&3200;
Output :
CHANGE-TAPRO:2190,,OPTISET,,,,VACANT,,,,,,DOOR,SPKR,,,,,,,,,;
CHANGE-TAPRO:2191,,OPTISET,MB,ST,SNR,,VACANT,,,,,,,,,,,,,,,;
CHANGE-TAPRO:2193,,OPTISET,,CONS,,,,,,MB,,,,,,,,,,,,;
CHANGE-TAPRO:2193,,OPTIA3,,,,,,,,,,,,SNR,,,,,,,,;
CHANGE-TAPRO:2194,,OPTISET,,CONS,,,,,,MB,,,,,,,,,,,,;
CHANGE-TAPRO:2194,,OPTIA2,,,,,,,,,DR,,,,,,,,,,,;
CHANGE-TAPRO:2194,,OPTIA4,,,,,,,,DOOR,,,,SNR,,,,,,,,;
85
EN4401EN00EN_0005
© 2005 Siemens AG
Administration: TAPRO - Key Programming Siemens
The key layout is regenerated for all terminals whose station numbers lie within the specified
range of 3154 to 3200, regardless of the terminal type, and whose key layout differs from stan-
dard.
3. Regenerate the key layouts which differ from standard for all optiset terminals with stand-
ard 0.
Input:
REGENERATE-TAPRO:TYPE=STN,STD=0,DIGTYP=OPTISET;
Output:
CHANGE-TAPRO:2191,,OPTISET,MB,ST,SNR,,VACANT,,,,,,,,,,,,,,,;
CHANGE-TAPRO:3500,,OPTIA2,CBK,,,,,,,,,,,,,,,,,,,;
All digital optiset terminals with the specified standard key layout, and whose key layout differs
from standard, are output according to station number.
86
EN4401EN00EN_0005
© 2005 Siemens AG
Siemens Administration: ZIEL - Destination Addresses for Stations
87
EN4401EN00EN_0005
© 2005 Siemens AG
Administration: ZIEL - Destination Addresses for Stations Siemens
Fixed destinations can be created for each service. This AMO however does not activate or de-
activate forwarding. Destinations can be entered in the services VCE (voice), FAX and DTE.
Destinations for devices working to the DSS1 protocol can only be activated as variable for-
warding destinations by AMO ACTDA.
Destinations can be entered for all created STNOs (station numbers) with the exception of at-
tendant terminals, irrespective of whether or not the station concerned has any terminal devic-
es.
The following diversion types can be used:
for SYSTEM forwarding
● CFU (Call Forward Unconditional)
● CFB (Call Forward Busy)
● CFNR (Call Forward No Reply)
● CFDND (Call Forward Do Not Disturb)
for STATION forwarding
● CFU (Call Forward Unconditional)
At the system forwarding it is distinguished, whether it is operative for internal or external calls.
Destinations can be entered for all added phone numbers except attendant consoles, immate-
rial, if a device is installed or not.
The following destinations are allowed:
● Existing station numbers and hunting group masters for each service
● Personal attendant call numbers
● General attendant call numbers
● Specific hunting groups
● PSs (paging systems, also ’code calling’ systems)
● Voice mailboxes
● Announcements via TMOM (adapter set for special equipment)
● External destinations
● ACD (automatic call distribution) DNIS (dialed number identification service) routing num-
ber
Destinations are not checked any more, except for few cases. To external destinations a name
can be assigned.
More informations about call forwarding can be found in the service handbook.
88
EN4401EN00EN_0005
© 2005 Siemens AG
Siemens Administration: ZIEL - Destination Addresses for Stations
Messenger Call
The members of an integrated executive/secretary system can have a messenger call key on
their voice terminal for which a fixed destination can be entered. This destination can also be
programmed at the administration and maintenance terminal. Only analog stations are permit-
ted.
Name/repertory key
The key functions for the OPTISET and Optipoint 500 are defined with the help of the AMO
TAPRO. Destinations can only be entered after the key functions have been defined. The des-
tination entry may be any combination of digits comprising a maximum of 22 characters.
Destination entries may be protected against changing and deleting by the destination terminal
user, using parameter PROTECT=YES. Changing or deleting by AMO will be possible further-
more.
Name/repertory keys of OPTISET / Optipoint 500 add on terminals have two levels to store des-
tination entries. A level can be selected by entering a value for parameter LEVEL.
89
EN4401EN00EN_0005
© 2005 Siemens AG
Administration: ZIEL - Destination Addresses for Stations Siemens
The destinations are entered into a storage area that can hold up to 42
The configuration is carried out when the attendant console is created by means of AMO AC-
SU.
The destination keys write memory locations 1-40, while the trunk group keys R1 and R2 are
always defined at locations 41 and 42.
15.1 ADD-ZIEL
Example
A fixed call forwarding destination for diversion type CFNR to STNO 3101 for the VOICE service
can be created for voice station 2100.
Input:
ADD-ZIEL:TYPE=FWD,SRCNO=2100,SI=VCE,DESTNOF=3101,DTYPE=CFNR,ITYPE=GEN
,CFVAR=SYSTEM;
15.2 DISPLAY-ZIEL
Example
Interrogate the call forwarding destination for station 2100.
Input:
DISPLAY-ZIEL:TYPE=FWD,SRCNO=2100;
Output:
FWD
SOURCE | SERVICE | DTYPE | ITYPE | CFVAR | DESTINATION
-------+----------+-------+---------+---------+-----------------------
2100 | VCE | CFU | INT | SYSTEM | 3140
90
EN4401EN00EN_0005
© 2005 Siemens AG
Siemens Administration: ZIEL - Destination Addresses for Stations
15.3 REGENERATE-ZIEL
Example
Regenerate the call forwarding destination for station 2100.
Input:
REGENERATE-ZIEL:TYPE=FWD,SRCNO=2100;
Output
ADD-ZIEL :FWD,2100,VCE,2100,VCE,3101,,CFNR,GEN,SYSTEM;
91
EN4401EN00EN_0005
© 2005 Siemens AG
Administration: ACTDA - Activation of User Features Siemens
TYPE Feature
STN DND Do-not-disturb
FWD Fixed call forwarding
Variable call forwarding
OPTISET individual optiset E / optipoint 500 settings
OUTHUNT switch out of hunt group
RCUTOFF Ringer Cutoff
REMIND Timed reminder
REPSECR Deputy for secretary
RNGXFER Ring transfer
VCR Voice call rejection
ATNDGR NOPT Night variant for ATNDGR
ITR DNDGR Group do-not-disturb function
ISTR Controlled station-to-station restriction
Controlled station-to-station restriction for all ISTR groups
MOBHFA MLOGOFF Logoff of mobile hfa-user
MLOGON Logon of mobile hfa-user
92
EN4401EN00EN_0005
© 2005 Siemens AG
Siemens Administration: ACTDA - Activation of User Features
Some user data is already administrated by other AMOs. These data are not additionally ad-
ministrated by ACTDA.
AMO Feature-specific data
CHESE Secretarial transfer function destinations
ZIEL Individual speed dialing numbers
Call numbers for stored number redial
Name/repertory key data for DIGITEs
DSS (direct station selection) destinations
Messenger call destinations
Name/repertory key data for ATNDs
TAPRO Store key functions for DIGITEs
BERUM Data for class-of-service changeovers (individual, group, all)
16.1 ADD-ACTDA
Create the feature-specific user data in the database.
Note:
If no entry is made for parameter ACT in the branch ATNDGR, the entered night option will be
preselected, but not activated.
Examples
1. Enter a variable call-forwarding destination (and activate) and enter a timed reminder for
STN 62850.
Input:
ADD-ACTDA:STN,62850,FWD,STATIONV,CFU,GEN,VCE,63627;
ADD-ACTDA:STN,62850,REMIND,01130;
Output:
H04 : NIGHT SWITCH FOR ATND GROUP 2 ACTIVATED.
93
EN4401EN00EN_0005
© 2005 Siemens AG
Administration: ACTDA - Activation of User Features Siemens
16.2 DELETE-ACTDA
Deactivate the features FWD and ’Voice Call Rejection’ for a station.
Example 1
Deactivate FWD for station 250123 in service FAX.
Input:
DELETE-ACTDA:STN,250123,FWD,,,,FAX;
16.3 DISPLAY-ACTDA
Interrogate the feature-specific data in the database for a specific station, ITR groups, or ATND
groups.
Examples
1. Display the features for the stations 250200 to 250220.
Input:
DISPLAY-ACTDA:STN,250200&&250220;
Output:
+--------------------------------------------------------------------+
| STATION NUMBER 250200 |
+--------------------------------------------------------------------|
| DIVERSION : |
| DESTINATION NUMBER | CFVAR | DTYPE | ITYPE | SI |
| | | | | |
+------------------------+----------+----------+----------+----------+
| 250201 | STATIONV | CFBNR | GEN | VCE |
+------------+-----------+----------+----------+----------+----------+
| DO NOT | VOICE CALL| RING | REP. | REMIND | RINGER- |
| DISTURB | REJECT | XFER .| SECR. | HH:MM | CUTOFF |
+------------+-----------+----------+----------+----------+----------+
| | x | | | 11:00 | |
+------------+-----------+----------+----------+----------+----------+
| INDIVIDUAL SETTINGS FOR OPTISET AND OPTIPOINT 500: |
| RINGVOL : 3 RINGSOUN: 5 ALERTVOL: 3 CALLVOL: 3 |
| SPKRVOL : 2 ROOMCHAR: NORMAL |
+--------------------------------------------------------------------+
+--------------------------------------------------------------------+
| STATION NUMBER 250210 |
+--------------------------------------------------------------------+
| DIVERSION : |
| DESTINATION NUMBER | CFVAR | DTYPE | ITYPE | SI |
| | | | | |
94
EN4401EN00EN_0005
© 2005 Siemens AG
Siemens Administration: ACTDA - Activation of User Features
+------------------------+----------+----------+----------+----------+
| 08972247230 | STATIONV | CFU | EXT | VCE |
| 03038652226 | STATIONV | CFU | GEN | FAX |
+------------+-----------+----------+----------+----------+----------+
| DO NOT | VOICE CALL| RING | REP. | REMIND | RINGER- |
| DISTURB | REJECT | XFER .| SECR. | HH:MM | CUTOFF |
+------------+-----------+----------+----------+----------+----------+
| | x | | | 11:00 | |
+------------+-----------+----------+----------+----------+----------+
| INDIVIDUAL SETTINGS FOR OPTISET AND OPTIPOINT 500: |
| RINGVOL : 3 RINGSOUN: 5 ALERTVOL: 3 CALLVOL: 3 |
| SPKRVOL : 2 ROOMCHAR: NORMAL |
+--------------------------------------------------------------------+
| SWITCHED OUT OF HUNT GROUP IN SERVICE: VCE |
+------------+-----------+----------+----------+----------+----------+
+--------------------------------------------------------------------+
| STATION NUMBER 250211 |
+------------+-----------+----------+----------+----------+----------+
| DO NOT | VOICE CALL| RING | REP. | REMIND | RINGER- |
| DISTURB | REJECT | XFER .| SECR. | HH:MM | CUTOFF |
+------------+-----------+----------+----------+----------+----------+
| | x | | | 11:00 | |
+------------+-----------+----------+----------+----------+----------+
| INDIVIDUAL SETTINGS FOR OPTISET AND OPTIPOINT 500: |
| RINGVOL : 3 RINGSOUN: 5 ALERTVOL: 3 CALLVOL: 3 |
| SPKRVOL : 2 ROOMCHAR: NORMAL |
+--------------------------------------------------------------------+
16.4 REGENERATE-ACTDA
Example
Regenerate the feature-specific data in the database.
Input:
REGENERATE-ACTDA;
Output:
ADD-ACTDA:STN,62850,FWD,STATIONV,CFBNR,GEN,VCE,636271154;
ADD-ACTDA:STN,62850,REMIND,01130;
ADD-ACTDA:ITR,,DNDGR;
95
EN4401EN00EN_0005
© 2005 Siemens AG
Administration: SDAT - Administration of Individual Subscriber Attributes and Siemens
17.1 CHANGE-SDAT
96
EN4401EN00EN_0005
© 2005 Siemens AG
Siemens Administration: SDAT - Administration of Individual Subscriber Attributes and
17.2 DELETE-SDAT
The action DELETE-SDAT can be used to delete specific subscriber attributes which were con-
figured with CHANGE-SDAT, TYPE=DATA1.
PUBNUM
When deleting PUBNUM the parameters TON and NPI are deleted, too.
17.3 DISPLAY-SDAT
The action DISPLAY-SDAT results in the following:
1. In the branch SUBDATA
the general subscriber data and the subscriber-related attributes / features of a subscriber
are output in tabular form.
2. In the branch SUBFIND
subscribers with a particular subscriber-related attribute / feature are output in tabular
form.
3. In the branch SUBOV
the assigned device and the AMO used to add the subscriber are output in tabular form for
the subscribers entered.
4. In the branch NNOFIND
subscribers with a particular NNO are output in tabular form.
Example 1
Input:
DISP-SDAT:2100,SUBDATA;
Output:
--------------------------- SUBSCRIBERDATA ----------------------------
STNO = 2100 COS1 = 22 DPLN = 0 SSTNO = NO
PEN : 1- 1- 25- 0 COS2 = 1 ITR = 7 TRACE = NO
DVCFIG : ANATE LCOSV1 = 1 COSX = 0 ALARMNO = 0
AMO : SCSU LCOSV2 = 1 SPDI = 10 RCBKB = NO
KEYSYS: LCOSD1 = 1 SPDC1 = 0 RCBKNA = NO
LCOSD2 = 1 SPDC2 = 1
-----------------------------------------------------------------------
CDRACC =
97
EN4401EN00EN_0005
© 2005 Siemens AG
Administration: SDAT - Administration of Individual Subscriber Attributes and Siemens
Example 2
Input:
DISP-SDAT:2100&&2120,SUBFIND,AGENT;
Output:
-------------------------------------------
STNO DVCFIG AMO CDRACC NNO
-------------------------------------------
2100 ANATE SCSU 1-1-15
Example 3
Input:
DISP-SDAT:2100&&2110,SUBOV;
Output:
STNO = 2100 DVCFIG: ANATE AMO: SCSU
--------------------------------------------
STNO DVCFIG AMO CDRACC NNO
--------------------------------------------
2100 ANATE SCSU 1-1-15
2101 ANATE 1-1-15
2102 ANATE 1-1-15
2103 ANATE 1-1-15
2104 ANATE 1-1-15
2105 ANATE 1-1-15
2106 ANATE 1-1-15
98
EN4401EN00EN_0005
© 2005 Siemens AG
Siemens Administration: SDAT - Administration of Individual Subscriber Attributes and
17.4 REGENERATE-SDAT
The action REGENERATE-SDAT can be used to restrict the output to subscribers with
particular subscriber-related attributes / features.
Example:
Input:
REGEN-SDAT:2190,ATTRIBUT;
Output:
CHANGE-SDAT:2190,AATTR=AGENT&AUTOLOG&DNDSR&CBSTMON;
99
EN4401EN00EN_0005
© 2005 Siemens AG
Administration: PERSI - Personal Identification Siemens
100
EN4401EN00EN_0005
© 2005 Siemens AG
Siemens Administration: PERSI - Personal Identification
The "class of PIN" (COPIN) is used for each PIN type in order to implement the PIN display
feature and in order to distinguish between the different PIN types.
The characteristics of the COPINs (1 through 15) are summarized in the so-called COPIN table
in which the following default values are assigned to the type of PIN:
18.1 ADD-PERSI
1. Definition of general PIN data
Create length of pins for each PIN type.
Create pin-display for each PIN type.
Create class of service changeover to COS2 with COSXCD.
Create number of failed attempts to enter the pin
2. Assigning a company code to an ITR group
3. Assigning the name and PIN to the STNO; assigning org. unit to name.
4. STNO-Code calling number conversion for CCMS.
If a range of station numbers is to be specified, the parameter ALLOC can be used to de-
termine whether the specified code calling number is to be assigned to all station numbers
101
EN4401EN00EN_0005
© 2005 Siemens AG
Administration: PERSI - Personal Identification Siemens
(ALLOC=SAME) or whether, starting with the specified code calling number, each station
number is to be assigned a new code calling number in ascending order (ALLOC=AS-
CEND).
5. Create project code (PCODE)
6. Create service id (SI)
7. Create account code (CDRAC)
Examples
1. Create the length of the personal ID number (card) (=8) and the pointer to the personal ID
number (card) (=7) (the manual personal ID numbers and the codes for class of service
changeover remain blocked).
Input:
ADD-PERSI:TYPE=SYS,PINCLEN=8,PINPOINT=7;
3. Create a STNO-Code calling number allocation for CCMS with code *7, with station
number range 2500-2520, with code calling number 300 to be allocated in ascending order.
Input:
ADD-PERSI:TYPE=CCMS,CCMSCD=*7,STNO=2500&&2520,CCNO=300,ALLOC=ASCEND;
6. Create the same pin for pinc and pin1 (length of pinc, pin1 and pin4=8)
Input:
ADD-PERSI:TYPE=STN,STNO=2100,PINC=21000000,PIN1=21000000,PININDIV=YES;
102
EN4401EN00EN_0005
© 2005 Siemens AG
Siemens Administration: PERSI - Personal Identification
18.2 CHANGE-PERSI
1. Change the length entries for each pin type. Any type of PIN can be deactivated by speci-
fying "0" as PIN length.
(this is only possible if the relevant PINs have not been created already)
2. Change the pointer indicating the card personal ID number
3. Change the company code or the pointer indicating the company code
4. Change one of the assigned names
5. Change one of the assigned ORG entries. This entry will be automatically changed for all
names to which it is assigned.
6. Change one of the assigned ORG entries for all names assigned to the specified station
number(s).
7. Change one of the assigned ORG entries for a specific name.
8. Change specific codes
(OLDCODE and NEWCODE must be of equal length)
If the same COSXCD is assigned to several different station numbers, the code can be
changed only for the station concerned by specifying the station number. If the station
number is omitted, the code will be changed for all station numbers.
9. Change the code-calling number associated with a registered station number for a partic-
ular CCMS.
10. Change the COPIN in the COPIN table
11. Change the modulo check algorithm
Notes:
CHANGE-PERSI:TYPE=ORGSYS or TYPE=ORGSTNO:
If several OLDORGs are to be changed to a NEWORG (new organizational unit), the NEWORG
must be specified only once. All remaining OLDORGs will then be assigned this NEWORG.
CHANGE-PERSI:TYPE=ORGNAME:
If a NEWORG is to be allocated for several names (change existing ORG to another), then the
NEWORG need be entered only once. All remaining names are then allocated the new orga-
nizational unit.
CHANGE-PERSI:TYPE=NAME:
If the first name (i.e. the name which is displayed on the screen) is to be changed, the param-
eter OLDNAME can be omitted and the name which used to be the first name is overwritten
with the first NEWNAME.
103
EN4401EN00EN_0005
© 2005 Siemens AG
Administration: PERSI - Personal Identification Siemens
CHANGE-PERSI:TYPE=PIN:
If the same COSXCD is assigned to several different stations, the STNO parameter needs to
be specified only when changing the COSXCD.
Examples
Assignment of station number.3109 designated ’FLIERL*GABI’ to a new organizational unit
designated ’PN V8332’.
Input:
CHANGE-PERSI:TYPE=ORGNAME,STNO=3109,NAME=FLIERL*GABI,NEWORG=PN V8332;
18.3 DELETE-PERSI
1. All assigned company codes are deleted for the specified traffic relation groups.
2. Delete all name entries (NAME and ORG) of a station DN
3. Delete Name(s) and ORG allocated to a station DN
4. Delete the specified ORG for all assigned names.
5. Delete all ORG units which are assigned to all names of a station number.
6. Delete the ORG unit which is assigned to a specific name of a station number.
7. Delete all codes indicated
Only for the PIN types specified under PINTYPE, or for all PIN types if the parameter is not
specified.
If the same COSXCD is assigned to several different station numbers, the code can be de-
leted only for the station concerned by specifying the station number. If the station number
is omitted, the code will be deleted for all station numbers.
8. Delete the codes assigned to the station numbers specified
Only for the PIN types specified under PINTYPE, or for all PIN types if the parameter is not
specified.
9. Delete station(s) from STNO/CCNO table for a particular CCMS.
Note
When NAMES or an organizational units which have been assigned to NAMES are deleted, the
surname and the name (but not any additional information) are compared with the station num-
ber entry.
The NAME may be abbreviated. Care should, however, be taken to specify as many letters as
104
EN4401EN00EN_0005
© 2005 Siemens AG
Siemens Administration: PERSI - Personal Identification
necessary to ensure that a specific station number entry is unique (see example of input).
If several entries of the same name exist for the same station number, the first of these entries
will be deleted.
Examples
1. Delete name ’RICCATO*’ from directory no.3100
Input:
DELETE-PERSI:TYPE=NAME,STNO=3100,NAME=RICCATO*;
Output:
H01: NAME TO BE DELETED RICCATO IS ONLY NAME FOR
ORG : ORG IS DELETED
3. The personal ID numbers (card) assigned to station number 7580 are to be deleted
DELETE-PERSI:TYPE=STN,STNO=7580,PINTYPE=6;
18.4 DISPLAY-PERSI
1. Interrogation of general personal ID data
(PIN length and pointer, COCO and pointer)
(Pin display for each pin type and class of service changeover)
2. Display the names and the assigned ORG for the specified/all station numbers.
3. Display PIN for all station numbers or for the specified station number(s).
4. Interrogation of STNO/CCNO entries for a particular CCMS.
5. Display the specified/all PINs for the specified/all pin types.
6. Display the specified/all COPINs of the COPIN table
7. Display all modulo check algorithms
105
EN4401EN00EN_0005
© 2005 Siemens AG
Administration: PERSI - Personal Identification Siemens
Examples
Interrogating the general PERSI data.
Input:
DISPLAY-PERSI:TYPE=SYS;
Output:
+---------------------------------------------+
| COPIN |
| 1 PIN1LEN 10 |
| 2 PIN2LEN 8 |
| 3 PIN3LEN 6 |
| 4 PIN4LEN 10 |
| 5 PIN5LEN 6 |
| 6 PINCLEN 8 PINPOINT 10 |
| 7 COSLEN 4 COSXCOS2 N |
| 8 SILEN 10 |
| 9 CDRACLEN 5 COSXCOS2 N |
| 10 PIN10LEN 4 |
| 11 PIN11LEN 2 |
| 12 PIN12LEN 2 |
| 13 PIN13LEN 2 |
| 14 PIN14LEN 2 |
| 15 PIN15LEN 2 |
| |
| ATTEMPTS 5 (NUMBER OF FAILED ATTEMPTS)|
| |
| ITR COCO CPOINT |
| 04 SIE 4 |
| 06 SIE 4 |
| 07 AGFA 8 |
| 08 BMW 6 |
+---------------------------------------------+
Output:
+--------+---------------------------------+--------------------------+
| STNO | CHRISTIAN AND SURNAME | ORGANIZATIONAL UNIT |
+--------+---------------------------------+--------------------------+
| 3100 | RICCATO* | |
| 3101 | BINDER* | PNEA 41 |
| 3102 | DUMONT* | |
| 3103 | BULLE* | |
| 3104 | TEAM ASSISTANT* | |
+--------+---------------------------------+--------------------------+
106
EN4401EN00EN_0005
© 2005 Siemens AG
Siemens Administration: PERSI - Personal Identification
Output:
+--------------+--------+------------------------------------+
| PIN | STNO | PINTYPE |
| | | 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15|
+--------------+--------+------------------------------------+
| 12345678 | 7580 | X . . . . X . . . . . . . . . |
| 23456789 | 4500 | X . . . . X . . . . . . . . . |
| 20007777 | 7580 | X . . . . X . . . . . . . . . |
+--------------+--------+------------------------------------+
10. Interrogation of card personal ID numbers to station numbers 4700 and 5600
Input:
DISPLAY-PERSI:TYPE=STN,STNO=4700&5600,PINTYPE=6;
Output:
+--------+-----------+------------------------------------+
| STNO | PIN | PINTYPE |
| | | 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15|
+--------+-----------+------------------------------------+
| 4700 | 10000009 | . . . . . X . . . . . . . . . |
| 5600 | 12345678 | X . . . . X . . . . . . . . . |
| 5600 | 23456789 | X . . . . X . . . . . . . . . |
+--------+-----------+------------------------------------+
Output:
+--------------+--------+------------------------------------+
| PIN | STNO | PINTYPE |
| | | 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15|
+--------------+--------+------------------------------------+
| 1111 | 4711 | X . X . . . . . . . . . . . . |
| 1234 | 4712 | X X X . . . . . . . . . . . . |
| 12345 | ---- | . . . . X . . . . . . . . . . |
+--------------+--------+------------------------------------+
107
EN4401EN00EN_0005
© 2005 Siemens AG
Administration: PERSI - Personal Identification Siemens
Output:
+--------------+--------+------------------------------------+
| PIN | STNO | PINTYPE |
| | | 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15|
+--------------+--------+------------------------------------+
| 4444444 | 4712 | . . . . . . X . . . . . . . . |
+--------------+--------+----------------------------------+
13. Interrogation of all pins with the assigned station number 4711
Input:
DISPLAY-PERSI:TYPE=STN,STNO=4711;
Output:
+--------+--------------+------------------------------------+
| STNO | PIN | PINTYPE |
| | | 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15|
+--------+--------------+------------------------------------+
| 4711 | 1111 | X . X . . . . . . . . . . . . |
| | 22222 | . . . X . . . . . . . . . . . |
+--------+--------------+------------------------------------+
Output:
+-------+-------------------------------------------------+
| COPIN | COPIN-PARAMETER |
+-------+-------------------------------------------------+
| 1 | COTYPE = MOBILE |
| | PINTEXT = ’MAN. PIN MOBILE USER’ |
| | PIN1LEN = 0 |
| | CDRTEXTS = NO |
| | CDRTEXT = ’ ’ |
| | DISPRSTN = NO IDHOME = NO |
| | PINTEST = TABLE DISPID = PERMDISP |
| | TRKCD = 0 TRACE = NO |
| | TRKCDTYP = NO PINEXT = NO |
| | PINDUR = TIME DISPPIN = NO |
| | TRANSFER = ALL PINNKEY = NO |
| | DEACKEY = NO POSCHKN = 1 |
108
EN4401EN00EN_0005
© 2005 Siemens AG
Siemens Administration: PERSI - Personal Identification
| | COSHOME = NO PINLCOS2 = NO |
| | DPTEST = NO DISPTRKC = NO |
+-------+-------------------------------------------------+
| 2 | COTYPE = BUSLONG |
| | PINTEXT = ’BUSINESS PIN, LONG ’ |
| | PIN2LEN = 0 |
| | CDRTEXTS = YES |
| | CDRTEXT = ’+ 0 ’ |
| | DISPRSTN = YES IDHOME = NO |
| | PINTEST = TABLE DISPID = TIMEDISP |
| | TRKCD = 0 TRACE = NO |
| | TRKCDTYP = NO PINEXT = NO |
| | PINDUR = PERM DISPPIN = NO |
| | TRANSFER = NO PINNKEY = NO |
| | DEACKEY = NO POSCHKN = 1 |
| | COSHOME = NO PINLCOS2 = NO |
| | DPTEST = NO DISPTRKC = NO |
+-------+-------------------------------------------------+
| 3 | COTYPE = BUSSHRT |
| | PINTEXT = ’BUSINESS PIN, 1 CALL’ |
| | PIN3LEN = 0 |
| | CDRTEXTS = YES |
| | CDRTEXT = ’+ 1 ’ |
| | DISPRSTN = YES IDHOME = NO |
| | PINTEST = TABLE DISPID = TIMEDISP |
| | TRKCD = 0 TRACE = NO |
| | TRKCDTYP = UNICD PINEXT = NO |
| | PINDUR = ONE DISPPIN = NO |
| | TRANSFER = NO PINNKEY = NO |
| | DEACKEY = NO POSCHKN = 1 |
| | COSHOME = NO PINLCOS2 = NO |
| | DPTEST = NO DISPTRKC = NO |
+-------+-------------------------------------------------+
| 4 | COTYPE = PRIVSHRT |
| | PINTEXT = ’PRIVATE PIN, 1 CALL ’ |
| | PIN4LEN = 0 |
| | CDRTEXTS = YES |
| | CDRTEXT = ’+ 2 ’ |
| | DISPRSTN = YES IDHOME = NO |
| | PINTEST = TABLE DISPID = TIMEDISP |
| | TRKCD = 0 TRACE = NO |
| | TRKCDTYP = UNICD PINEXT = NO |
| | PINDUR = ONE DISPPIN = NO |
| | TRANSFER = NO PINNKEY = NO |
| | DEACKEY = NO POSCHKN = 1 |
| | COSHOME = NO PINLCOS2 = NO |
| | DPTEST = NO DISPTRKC = NO |
+-------+-------------------------------------------------+
| 5 | COTYPE = PCODE |
| | PINTEXT = ’PROJECT CODE, 1 CALL’ |
| | PIN5LEN = 0 |
| | CDRTEXTS = NO |
109
EN4401EN00EN_0005
© 2005 Siemens AG
Administration: PERSI - Personal Identification Siemens
| | CDRTEXT = ’ ’ |
| | DISPRSTN = NO IDHOME = NO |
| | PINTEST = LENGTH DISPID = PERMDISP |
| | TRKCD = 0 TRACE = NO |
| | TRKCDTYP = NO PINEXT = YES |
| | PINDUR = ONE DISPPIN = YES |
| | TRANSFER = NO PINNKEY = NO |
| | DEACKEY = NO POSCHKN = 1 |
| | COSHOME = NO PINLCOS2 = NO |
| | DPTEST = NO DISPTRKC = NO |
+-------+-------------------------------------------------+
| 6 | COTYPE = PIN CARD |
| | PINTEXT = ’ID CARD, MOBILE USER’ |
| | PINCLEN = 0 |
| | CDRTEXTS = NO |
| | CDRTEXT = ’ ’ |
| | DISPRSTN = NO IDHOME = NO |
| | PINTEST = TABLE DISPID = PERMDISP |
| | TRKCD = - TRACE = NO |
| | TRKCDTYP = NO PINEXT = NO |
| | PINDUR = PERM DISPPIN = NO |
| | TRANSFER = ALL PINNKEY = NO |
| | DEACKEY = NO POSCHKN = 1 |
| | COSHOME = NO PINLCOS2 = NO |
| | DPTEST = NO DISPTRKC = NO |
+-------+-------------------------------------------------+
| 7 | COTYPE = COSXCD |
| | PINTEXT = ’COS SWITCHOVER CODE ’ |
| | COSLEN = 0 |
| | CDRTEXTS = NO |
| | CDRTEXT = ’ ’ |
| | DISPRSTN = NO IDHOME = NO |
| | PINTEST = TABLE DISPID = TIMEDISP |
| | TRKCD = - TRACE = NO |
| | TRKCDTYP = NO PINEXT = NO |
| | PINDUR = - DISPPIN = NO |
| | TRANSFER = NO PINNKEY = NO |
| | DEACKEY = NO POSCHKN = 1 |
| | COSHOME = NO PINLCOS2 = NO |
| | DPTEST = NO DISPTRKC = NO |
+-------+-------------------------------------------------+
| 8 | COTYPE = SI |
| | PINTEXT = ’PIN FOR SERVICE ID ’ |
| | SILEN = 0 |
| | CDRTEXTS = NO |
| | CDRTEXT = ’ ’ |
| | DISPRSTN = NO IDHOME = NO |
| | PINTEST = TABLE DISPID = TIMEDISP |
| | TRKCD = 0 TRACE = NO |
| | TRKCDTYP = NO PINEXT = NO |
| | PINDUR = - DISPPIN = NO |
| | TRANSFER = NO PINNKEY = NO |
110
EN4401EN00EN_0005
© 2005 Siemens AG
Siemens Administration: PERSI - Personal Identification
| | DEACKEY = NO POSCHKN = 1 |
| | COSHOME = NO PINLCOS2 = NO |
| | DPTEST = NO DISPTRKC = NO |
+-------+-------------------------------------------------+
| 9 | COTYPE = PCODE |
| | PINTEXT = ’CDR ACCOUNT CODE ’ |
| | CDRACLEN = 5 |
| | CDRTEXTS = NO |
| | CDRTEXT = ’ ’ |
| | DISPRSTN = NO IDHOME = NO |
| | PINTEST = LENGTH DISPID = PERMDISP |
| | TRKCD = 0 TRACE = NO |
| | TRKCDTYP = NO PINEXT = YES |
| | PINDUR = ONE DISPPIN = YES |
| | TRANSFER = NO PINNKEY = NO |
| | DEACKEY = NO POSCHKN = 1 |
| | COSHOME = NO PINLCOS2 = NO |
| | DPTEST = NO DISPTRKC = NO |
+-------+-------------------------------------------------+
| 10 | COTYPE = PCODE |
| | PINTEXT = ’FAC, 1 CALL ’ |
| | PIN10LEN = 0 |
| | CDRTEXTS = NO |
| | CDRTEXT = ’ ’ |
| | DISPRSTN = NO IDHOME = NO |
| | PINTEST = LENGTH DISPID = PERMDISP |
| | TRKCD = 0 TRACE = NO |
| | TRKCDTYP = NO PINEXT = YES |
| | PINDUR = ONE DISPPIN = YES |
| | TRANSFER = NO PINNKEY = NO |
| | DEACKEY = NO POSCHKN = 1 |
| | COSHOME = NO PINLCOS2 = NO |
| | DPTEST = NO DISPTRKC = NO |
+-------+-------------------------------------------------+
| 11 | COTYPE = MOBILE |
| | PINTEXT = ’MAN. PIN MOBILE USER’ |
| | PIN11LEN = 0 |
| | CDRTEXTS = NO |
| | CDRTEXT = ’ ’ |
| | DISPRSTN = NO IDHOME = NO |
| | PINTEST = TABLE DISPID = PERMDISP |
| | TRKCD = 0 TRACE = NO |
| | TRKCDTYP = NO PINEXT = NO |
| | PINDUR = TIME DISPPIN = NO |
| | TRANSFER = ALL PINNKEY = NO |
| | DEACKEY = NO POSCHKN = 1 |
| | COSHOME = NO PINLCOS2 = NO |
| | DPTEST = NO DISPTRKC = NO |
+-------+-------------------------------------------------+
| 12 | COTYPE = MOBILE |
| | PINTEXT = ’MAN. PIN MOBILE USER’ |
| | PIN12LEN = 0 |
111
EN4401EN00EN_0005
© 2005 Siemens AG
Administration: PERSI - Personal Identification Siemens
| | CDRTEXTS = NO |
| | CDRTEXT = ’ ’ |
| | DISPRSTN = NO IDHOME = NO |
| | PINTEST = TABLE DISPID = PERMDISP |
| | TRKCD = 0 TRACE = NO |
| | TRKCDTYP = NO PINEXT = NO |
| | PINDUR = TIME DISPPIN = NO |
| | TRANSFER = ALL PINNKEY = NO |
| | DEACKEY = NO POSCHKN = 1 |
| | COSHOME = NO PINLCOS2 = NO |
| | DPTEST = NO DISPTRKC = NO |
+-------+-------------------------------------------------+
| 13 | COTYPE = MOBILE |
| | PINTEXT = ’MAN. PIN MOBILE USER’ |
| | PIN13LEN = 0 |
| | CDRTEXTS = NO |
| | CDRTEXT = ’ ’ |
| | DISPRSTN = NO IDHOME = NO |
| | PINTEST = TABLE DISPID = PERMDISP |
| | TRKCD = 0 TRACE = NO |
| | TRKCDTYP = NO PINEXT = NO |
| | PINDUR = TIME DISPPIN = NO |
| | TRANSFER = ALL PINNKEY = NO |
| | DEACKEY = NO POSCHKN = 1 |
| | COSHOME = NO PINLCOS2 = NO |
| | DPTEST = NO DISPTRKC = NO |
+-------+-------------------------------------------------+
| 14 | COTYPE = MOBILE |
| | PINTEXT = ’MAN. PIN MOBILE USER’ |
| | PIN14LEN = 0 |
| | CDRTEXTS = NO |
| | CDRTEXT = ’ ’ |
| | DISPRSTN = NO IDHOME = NO |
| | PINTEST = TABLE DISPID = PERMDISP |
| | TRKCD = 0 TRACE = NO |
| | TRKCDTYP = NO PINEXT = NO |
| | PINDUR = TIME DISPPIN = NO |
| | TRANSFER = ALL PINNKEY = NO |
| | DEACKEY = NO POSCHKN = 1 |
| | COSHOME = NO PINLCOS2 = NO |
| | DPTEST = NO DISPTRKC = NO |
+-------+-------------------------------------------------+
| 15 | COTYPE = MOBILE |
| | PINTEXT = ’MAN. PIN MOBILE USER’ |
| | PIN15LEN = 0 |
| | CDRTEXTS = NO |
| | CDRTEXT = ’ ’ |
| | DISPRSTN = NO IDHOME = NO |
| | PINTEST = TABLE DISPID = PERMDISP |
| | TRKCD = 0 TRACE = NO |
| | TRKCDTYP = NO PINEXT = NO |
| | PINDUR = TIME DISPPIN = NO |
112
EN4401EN00EN_0005
© 2005 Siemens AG
Siemens Administration: PERSI - Personal Identification
18.5 REGENERATE-PERSI
1. Regeneration of the general or of all general and individual user data for personal identifi-
cation, of the CCMS data, project codes and service ids.
2. Regeneration of the individual user data for personal identification.
3. Regeneration of project codes
4. Regeneration of service ids
5. Regeneration of CDR account codes
6. Regeneration of COPINs
7. Regeneration of modulo check algorithm
If no parameter is specified, all general and individual user data as well as all CCMS data is
regenerated for personal identification.
If parameter STNO is omitted, all names, organizational units, and PINs in the system are re-
generated.
1. Regenerate all entries
Input:
REG-PERSI:;
Output:
ADD-PERSI:CCMS,922,,33&2100
,2105,GLEICH;
ADD-PERSI:ALG,7,3,5,6,5,5,5,6,10,5,4,2,2,2,2,2,1&2,JA;
ADD-PERSI:STN,3110,"SCHMIDT*HANNES","ORG1","60231100"&"70244817",
,,,,,,,,,,,YES,;
ADD-PERSI:PCODE,"600600"&"606060",5;
ADD-PERSI:SI,"5005005005";
ADD-PERSI:CDRAC,12345;
113
EN4401EN00EN_0005
© 2005 Siemens AG
Administration: PERSI - Personal Identification Siemens
BLE,0,UNICD,ONE,NO,NO,TIMEDISP,NO,NO,NO,NO,NO,1,NO,NO,NO,NO;
CHANGE-PERSI:COPIN,4,PRIVSHRT,"PRIVATE PIN, 1 CALL ",YES,"+ 2",YES,TA-
BLE,0,UNICD,ONE,NO,NO,TIMEDISP,NO,NO,NO,NO,NO,1,NO,NO,NO,NO;
CHANGE-PERSI:COPIN,5,PCODE,"PROJECT CODE, 1
CALL",NO,,NO,LENGTH,0,NO,ONE,NO,NO,PERMDISP,NO,YES,YES,NO,NO,1,NO,NO,NO,NO;
CHANGE-PERSI:COPIN,6,,"ID CARD, MOBILE USER",NO,,NO,TABLE,,NO,,ALL,NO,PERM-
DISP,NO,NO,NO,NO,NO,1,NO,NO,NO,NO;
CHANGE-PERSI:COPIN,7,,"COS SWITCHOVER CODE ",NO,,NO,TABLE,,NO,,NO,NO,TIME-
DISP,NO,NO,NO,NO,NO,1,NO,NO,NO,NO;
CHANGE-PERSI:COPIN,9,,"CDR ACCOUNT CODE ",NO,,NO,LENGTH,0,NO,ONE,NO,NO,PERM-
DISP,NO,YES,YES,NO,NO,1,NO,NO,NO,NO;
CHANGE-PERSI:COPIN,10,PCODE,"FAC, 1 CALL ",NO,,NO,LENGTH,0,NO,ONE,NO,NO,PERM-
DISP,NO,YES,YES,NO,NO,1,NO,NO,NO,NO;
CHANGE-PERSI:COPIN,11,MOBILE,"MAN. PIN MOBILE USER",NO,,NO,TA-
BLE,0,NO,TIME,ALL,NO,PERMDISP,NO,YES,YES,NO,NO,1,NO,NO,NO,NO;
CHANGE-PERSI:COPIN,12,MOBILE,"MAN. PIN MOBILE USER",NO,,NO,TA-
BLE,0,NO,TIME,ALL,NO,PERMDISP,NO,YES,YES,NO,NO,1,NO,NO,NO,NO;
CHANGE-PERSI:COPIN,13,MOBILE,"MAN. PIN MOBILE USER",NO,,NO,TA-
BLE,0,NO,TIME,ALL,NO,PERMDISP,NO,YES,YES,NO,NO,1,NO,NO,NO,NO;
CHANGE-PERSI:COPIN,14,MOBILE,"MAN. PIN MOBILE USER",NO,,NO,TA-
BLE,0,NO,TIME,ALL,NO,PERMDISP,NO,YES,YES,NO,NO,1,NO,NO,NO,NO;
CHANGE-PERSI:COPIN,15,MOBILE,"MAN. PIN MOBILE USER",NO,,NO,TA-
BLE,0,NO,TIME,ALL,NO,PERMDISP,NO,YES,YES,NO,NO,1,NO,NO,NO,NO;
CHANGE-PERSI:MODULO,1,2-1-2-1-2-1-2-1-2-1-2-1,SUMPRO,10,1,COMPREM;
CHANGE-PERSI:MODULO,2,2-1-2-1-2-1-2-1-2-1-2-1,SUMPRO,10,1,COMPREM;
CHANGE-PERSI:MODULO,3,2-1-2-1-2-1-2-1-2-1-2-1,SUMPRO,10,1,COMPREM;
114
EN4401EN00EN_0005
© 2005 Siemens AG