Data Sheet 6AG1515-2RM00-7AB0: General Information
Data Sheet 6AG1515-2RM00-7AB0: General Information
Data Sheet 6AG1515-2RM00-7AB0: General Information
General information
Product type designation CPU 1515R-2 PN
Display
Screen diagonal [cm] 6.1 cm
Control elements
Number of keys 6
Mode selector switch 1
Supply voltage
Type of supply voltage 24 V DC
permissible range, lower limit (DC) 19.2 V
permissible range, upper limit (DC) 28.8 V
Reverse polarity protection Yes
Mains buffering
● Mains/voltage failure stored energy time 5 ms
Input current
Current consumption (rated value) 0.8 A
Power loss
Power loss, typ. 6.3 W
Memory
Number of slots for SIMATIC memory card 1
SIMATIC memory card required Yes
Work memory
● integrated (for program) 500 kbyte
● integrated (for data) 3 Mbyte
Load memory
● Plug-in (SIMATIC Memory Card), max. 32 Gbyte
Backup
● maintenance-free Yes
CPU-blocks
Number of elements (total) 6 000; Blocks (OB, FB, FC, DB) and UDTs
DB
● Number range Number range: 1 to 59 999
● Size, max. 3 Mbyte; For non-optimized block accesses, the max. size of the
DB is 64 KB
FB
● Number range 0 ... 65 535
● Size, max. 500 kbyte
FC
● Number range 0 ... 65 535
● Size, max. 500 kbyte
OB
● Size, max. 500 kbyte
● Number of free cycle OBs 100
● Number of time alarm OBs 20
● Number of delay alarm OBs 20
● Number of cyclic interrupt OBs 20
● Number of process alarm OBs 50
● Number of startup OBs 100
● Number of asynchronous error OBs 4
● Number of synchronous error OBs 2
Address area
Number of IO modules 4 096; max. number of modules / submodules
I/O address area
● Inputs 32 kbyte; All inputs are in the process image
● Outputs 32 kbyte; All outputs are in the process image
per integrated IO subsystem
— Inputs (volume) 8 kbyte
— Outputs (volume) 8 kbyte
Subprocess images
● Number of subprocess images, max. 32
Time of day
Clock
● Backup time 6 wk; At 40 °C ambient temperature, typically
● Deviation per day, max. 10 s; Typ.: 2 s
Operating hours counter
● Number 16
Clock synchronization
● supported Yes
● in AS, master No
● in AS, slave No
● on Ethernet via NTP Yes
Interfaces
Number of PROFINET interfaces 1
1. Interface
Interface types
● RJ 45 (Ethernet) Yes; X1
● Number of ports 2
● integrated switch Yes
Protocols
● IP protocol Yes; IPv4
● PROFINET IO Controller Yes
● PROFINET IO Device No
● SIMATIC communication Yes; Only Server
● Open IE communication Yes
● Web server No
● Media redundancy Yes
PROFINET IO Controller
Services
— PG/OP communication Yes
— Isochronous mode No
— IRT No
— MRP Yes; Only Manager Auto, max. 50 nodes; only 16 are
recommended, however
— MRPD No
— PROFIenergy Yes
— Number of connectable IO Devices, max. 64
2. Interface
Interface types
● RJ 45 (Ethernet) Yes; X2
● Number of ports 1
● integrated switch No
Protocols
● IP protocol Yes; IPv4
● PROFINET IO Controller No
● PROFINET IO Device No
● SIMATIC communication Yes; Only Server
● Open IE communication Yes
● Web server No
● Media redundancy No
Interface types
RJ 45 (Ethernet)
● 100 Mbps Yes
● Autonegotiation Yes
● Autocrossing Yes
● Industrial Ethernet status LED Yes
Protocols
Number of connections
● Number of connections, max. 108
● Number of connections reserved for 10
ES/HMI/web
Redundancy mode
Media redundancy
— MRP Yes; Manager Auto is permanently set in TIA. Max. 50 nodes are
possible, 16 are recommended
— MRPD No
— Switchover time on line break, typ. 200 ms; PROFINET MRP
— Number of stations in the ring, max. 50; Only 16 are recommended, however
SIMATIC communication
● S7 routing No
● S7 communication, as server Yes
● S7 communication, as client No
Open IE communication
S7 message functions
Program alarms No
Interrupts/diagnostics/status information
Diagnostics indication LED
● RUN/STOP LED Yes
● ERROR LED Yes
● MAINT LED Yes
● Connection display LINK TX/RX Yes
Ambient conditions
Ambient temperature during operation
● horizontal installation, min. -40 °C; = Tmin (incl. condensation/frost); start-up @ -20 °C
● horizontal installation, max. 70 °C; Display: 50 °C, at an operating temperature of typically 50
°C, the display is switched off
● vertical installation, min. -40 °C; = Tmin (incl. condensation/frost); start-up @ -20 °C
● vertical installation, max. 40 °C; Display: 40 °C, at an operating temperature of typically 40
°C, the display is switched off
Ambient temperature during storage/transportation
● min. -40 °C
● max. 70 °C
Altitude during operation relating to sea level
● Ambient air temperature-barometric pressure- Tmin ... Tmax at 1 140 hPa ... 795 hPa (-1 000 m ... +2 000 m) //
altitude Tmin ... (Tmax - 10 K) at 795 hPa ... 658 hPa (+2 000 m ... +3 500
m) // Tmin ... (Tmax -20 K) at 658 hPa ... 540 hPa (+3 500 m ... +5
000 m)
Relative humidity
● With condensation, tested in accordance with 100 %; RH incl. condensation / frost (no commissioning in
IEC 60068-2-38, max. bedewed state), horizontal installation
Resistance
Coolants and lubricants
— Resistant to commercially available Yes; Incl. diesel and oil droplets in the air
coolants and lubricants
Use in stationary industrial systems
Configuration
Programming
Programming language
— LAD Yes
— FBD Yes
— STL Yes
— SCL Yes
— CFC No
— GRAPH No
Know-how protection
● User program protection/password protection Yes
● Copy protection No
Dimensions
Width 105 mm
Height 147 mm
Depth 129 mm
Weights
Weight, approx. 1 100 g
Other
Note: At temperatures below 0 °C legibility may be restricted and
representation of dynamic contents may be slower