Location via proxy:   [ UP ]  
[Report a bug]   [Manage cookies]                

M 9593 Mu52

Download as pdf or txt
Download as pdf or txt
You are on page 1of 1

Calibration Summary M-9593-MU52

Target Injection Pressure = 39.15 psid

FNPW_LSCOMP FNPW_BKCOMP
Pressure Multiplier Pressure Multiplier
ALOSL (lb/s) 0.017711 (psid) (psid)
AHISL (lb/s) 0.015851 20.01 0.7570 20.01 0.6519
FUEL_BKPT (lb) 0.0000162600 30.02 0.9577 30.02 0.8444
MINPW (ms) 0.730 39.15 1.0000 39.15 1.0000
50.03 1.1280 50.03 1.1415
54.96 1.3780 54.96 1.0449
60.03 1.3877 60.03 1.1039

FNPW_OFFSET FNPW_HSCOMP FNPW_OFFCOMP


VBAT Voltage Offset Pressure Multiplier Pressure Multiplier
(volts) (msec) (psid) (psid)
6 7.611 20.01 0.7149 20.01 0.7149
8 3.084 30.02 0.8756 30.02 0.8756
10 1.812 39.15 1.0000 39.15 1.0000
11 1.505 50.03 1.1304 44.95 1.0621
12 1.282 54.96 1.1945 50.03 1.1304
13 1.109 60.03 1.3020 54.96 1.2158
14 0.970 60.03 1.1638
15 0.856

ALOSL "low" injector slope


AHISL "high" injector slope
FUEL_BKPT Fuel mass at which to switch from low to high injector slope
MINPW Minimum repeatable fuel pulsewidth at 39.15 psid
FNPW_LSCOMP Multiplier to low slope as a function of injection pressure in psid
FNPW_HSCOMP Multiplier to high slope as a function of injection pressure in psid
FNPW_BKCOMP Multiplier to FUEL_BKPT as a function of injection pressure in psid
FNPW_OFFSET Injector voltage offset as a function of battery voltage
FNPW_OFFCOMP Multiplier on FNPW_OFFSET as a function of injection pressure in psid