12 - Sucker Rod Pumping - 2007 - Petroleum Production Engineering
12 - Sucker Rod Pumping - 2007 - Petroleum Production Engineering
12 - Sucker Rod Pumping - 2007 - Petroleum Production Engineering
12 Sucker Rod
Pumping
Contents
12.1 Introduction 12/162
12.2 Pumping System 12/162
12.3 Polished Rod Motion 12/165
12.4 Load to the Pumping Unit 12/168
12.5 Pump Deliverability and Power
Requirements 12/170
12.6 Procedure for Pumping Unit Selection 12/172
12.7 Principles of Pump Performance
Analysis 12/174
Summary 12/179
References 12/179
Problems 12/179
Guo, Boyun / Computer Assited Petroleum Production Engg 0750682701_chap12 Final Proof page 162 4.1.2007 2:43pm Compositor Name: SJoearun
12.1 Introduction by means of the walking beam through a pitman arm. The
horse’s head and the hanger cable arrangement is used to
Sucker rod pumping is also referred to as ‘‘beam pump-
ensure that the upward pull on the sucker rod string is
ing.’’ It provides mechanical energy to lift oil from bottom
hole to surface. It is efficient, simple, and easy for field vertical at all times (thus, no bending moment is applied to
people to operate. It can pump a well down to very low the stuffing box). The polished rod and stuffing box com-
pressure to maximize oil production rate. It is applicable to bine to maintain a good liquid seal at the surface and, thus,
slim holes, multiple completions, and high-temperature force fluid to flow into the ‘‘T’’ connection just below the
stuffing box.
and viscous oils. The system is also easy to change to
Conventional pumping units are available in a wide
other wells with minimum cost. The major disadvantages
of beam pumping include excessive friction in crooked/ range of sizes, with stroke lengths varying from 12 to
deviated holes, solid-sensitive problems, low efficiency in almost 200 in. The strokes for any pumping unit type are
gassy wells, limited depth due to rod capacity, and bulky in available in increments (unit size). Within each unit size,
offshore operations. Beam pumping trends include the stroke length can be varied within limits (about six
improved pump-off controllers, better gas separation, gas different lengths being possible). These different lengths
are achieved by varying the position of the pitman arm
handling pumps, and optimization using surface and
bottom-hole cards. connection on the crank arm.
Walking beam ratings are expressed in allowable pol-
ished rod loads (PRLs) and vary from approximately
3,000 to 35,000 lb. Counterbalance for conventional
12.2 Pumping System
pumping units is accomplished by placing weights directly
As shown in Fig. 12.1, a sucker rod pumping system on the beam (in smaller units) or by attaching weights to
consists of a pumping unit at surface and a plunger the rotating crank arm (or a combination of the two
pump submerged in the production liquid in the well. methods for larger units). In more recent designs, the
The prime mover is either an electric motor or an in- rotary counterbalance can be adjusted by shifting the posi-
ternal combustion engine. The modern method is to sup- tion of the weight on the crank by a jackscrew or rack and
ply each well with its own motor or engine. Electric motors pinion mechanism.
are most desirable because they can easily be automated. There are two other major types of pumping units. These
The power from the prime mover is transmitted to the are the Lufkin Mark II and the Air-Balanced Units
input shaft of a gear reducer by a V-belt drive. The output (Fig. 12.2). The pitman arm and horse’s head are in the
shaft of the gear reducer drives the crank arm at a lower same side of the walking beam in these two types of units
speed (4–40 revolutions per minute [rpm] depending on (Class III lever system). Instead of using counter-weights in
well characteristics and fluid properties). The rotary mo- Lufkin Mark II type units, air cylinders are used in the air-
tion of the crank arm is converted to an oscillatory motion balanced units to balance the torque on the crankshaft.
Pitman
Counter weight
Bridle Gear reducer
V-Belt
Prime
mover
Polished rod Stuffing
box Crank
Oil Sampson
Tee post
Gas
Casing
Tubing
Sucker rod
Stroke length
Stroke length
Downhole pump
Figure 12.1 A diagrammatic drawing of a sucker rod pumping system (Golan and Whitson, 1991).
Guo, Boyun / Computer Assited Petroleum Production Engg 0750682701_chap12 Final Proof page 163 4.1.2007 2:43pm Compositor Name: SJoearun
The American Petroleum Institute (API) has established beam counterbalance units, and M is for Mark II units.
designations for sucker rod pumping units using a string of The second field is the code for peak torque rating in
characters containing four fields. For example, thousands of inch-pounds and gear reducer. D stands for
C-- 228D-- 200-- 74: double-reduction gear reducer. The third field is the code
for PRL rating in hundreds of pounds. The last field is the
The first field is the code for type of pumping unit. C is for code for stroke length in inches.
conventional units, A is for air-balanced units, B is for
Walking beam
Fulcrum
an
Force
Pitm
Well
load
Counter
balance
(a)
Walking beam
Fulcrum
an
Force
Pitm
Well
load
Counter
balance
(b)
Walking beam
Fulcrum
Counter balance
Force
an
Pitm
Well
load
(c)
Figure 12.2 Sketch of three types of pumping units: (a) conventional unit; (b) Lufkin Mark II Unit; (c) air-balanced unit.
Guo, Boyun / Computer Assited Petroleum Production Engg 0750682701_chap12 Final Proof page 164 4.1.2007 2:43pm Compositor Name: SJoearun
Figure 12.3 illustrates the working principle of a plunger through the valve, which lets the plunger move to a po-
pump. The pump is installed in the tubing string sition just above the SV. During this downward motion of
below the dynamic liquid level. It consists of a working the plunger, the SV is closed; thus, the fluid is forced to
barrel and liner, standing valve (SV), and traveling valve pass through the TV.
(TV) at the bottom of the plunger, which is connected to When the plunger is at the bottom of the stroke and
sucker rods. starts an upward stroke, the TV closes and the SV opens.
As the plunger is moved downward by the sucker rod As upward motion continues, the fluid in the well below
string, the TV is open, which allows the fluid to pass the SV is drawn into the volume above the SV (fluid
Tubing
Sucker
rods
Working
barrel
and liner
Traveling
valve
plunger
Standing
valve
passing through the open SV). The fluid continues to fill conventional pumping units. Parameters are defined in
the volume above the SV until the plunger reaches the top Fig. 12.6.
of its stroke.
There are two basic types of plunger pumps: tubing Air-Balanced Pumping Unit. For this type of unit, the
pump and rod pump (Fig. 12.4). For the tubing pump, maximum acceleration occurs at the top of the stroke
the working barrel or liner (with the SV) is made up (i.e., (the acceleration at the bottom of the stroke is less than
attached) to the bottom of the production tubing string simple harmonic motion). Thus, a lower maximum stress is
and must be run into the well with the tubing. The plunger set up in the rod system during transfer of the fluid load to
(with the TV) is run into the well (inside the tubing) on the rods.
the sucker rod string. Once the plunger is seated in the
working barrel, pumping can be initiated. A rod pump The following analyses of polished rod motion apply to
(both working barrel and plunger) is run into the well on conventional units. Figure 12.7 illustrates an approximate
the sucker rod string and is seated on a wedged type motion of the connection point between pitman arm and
seat that is fixed to the bottom joint of the production walking beam.
tubing. Plunger diameters vary from 5⁄8 to 4 5⁄8 in. Plunger If x denotes the distance of B below its top position C
area varies from 0:307 in:2 to 17:721 in:2 . and is measured from the instant at which the crank arm
and pitman arm are in the vertical position with the crank
arm vertically upward, the law of cosine gives
12.3 Polished Rod Motion (AB)2 ¼ (OA)2 þ (OB)2 2(OA)(OB) cos AOB,
The theory of polished rod motion has been established that is,
since 1950s (Nind, 1964). Figure 12.5 shows the cyclic
motion of a polished rod in its movements through the h2 ¼ c2 þ (h þ c x)2 2c(h þ c x) cos vt,
stuffing box of the conventional pumping unit and the air- where v is the angular velocity of the crank. The equation
balanced pumping unit. reduces to
Conventional Pumping Unit. For this type of unit, the x2 2x[h þ c(1 cos vt)] þ 2c(h þ c)(1 cos vt) ¼ 0
acceleration at the bottom of the stroke is somewhat
greater than true simple harmonic acceleration. At the so that
pffiffiffiffiffiffiffiffiffiffiffiffiffiffiffiffiffiffiffiffiffiffiffiffiffiffiffiffiffiffiffiffiffiffiffiffiffiffiffiffiffiffiffi
top of the stroke, it is less. This is a major drawback for x ¼ h þ c(1 cos vt) c2 cos2 vt þ (h2 c2 ):
the conventional unit. Just at the time the TV is closing
and the fluid load is being transferred to the rods, the When vt is zero, x is also zero, which means that the
acceleration for the rods is at its maximum. These two negative root sign must be taken. Therefore,
pffiffiffiffiffiffiffiffiffiffiffiffiffiffiffiffiffiffiffiffiffiffiffiffiffiffiffiffiffiffiffiffiffiffiffiffiffiffiffiffiffiffiffi
factors combine to create a maximum stress on the rods x ¼ h þ c(1 cos vt) c2 cos2 vt þ (h2 þ c2 ):
that becomes one of the limiting factors in designing an
installation. Table 12.1 shows dimensions of some API Acceleration is
Conventional
unit
d2
d1 d2 d1
Polished Polished
rod rod
Air-balanced
unit
Figure 12.5 Polished rod motion for (a) conventional pumping unit and (b) air-balanced unit (Nind, 1964).
Guo, Boyun / Computer Assited Petroleum Production Engg 0750682701_chap12 Final Proof page 166 4.1.2007 2:43pm Compositor Name: SJoearun
A
C
P
R H
G
C-912D-365-168 210 120.03 120 148.5 237.88 86.88 47, 41, 35 1,500 80.32
C-912D-305-168 210 120.03 120 148.5 237.88 86.88 47, 41, 35 1,500 80.32
C-640D-365-168 210 120.03 120 148.5 237.88 86.88 47, 41, 35 1,500 80.32
C-640D-305-168 210 120.03 120 148.5 237.88 86.88 47, 41, 35 1,500 80.32
C-456D-305-168 210 120.03 120 148.5 237.88 86.88 47, 41, 35 1,500 80.32
C-912D-427-144 180 120.03 120 148.5 237.88 86.88 47, 41, 35 650 68.82
C-912D-365-144 180 120.03 120 148.5 237.88 86.88 47, 41, 35 650 68.82
C-640D-365-144 180 120.03 120 148.5 238.88 89.88 47, 41, 35 650 68.82
C-640D-305-144 180 120.08 120 144.5 238.88 89.88 47, 41, 35 520 68.45
C-456D-305-144 180 120.08 120 144.5 238.88 89.88 47, 41, 35 520 68.45
C-640D-256-144 180 120.08 120 144.5 238.88 89.88 47, 41, 35 400 68.45
C-456D-256-144 180 120.08 120 144.5 238.88 89.88 47, 41, 35 400 68.45
C-320D-256-144 180 120.08 120 144.5 238.88 89.88 47, 41, 35 400 68.45
C-456D-365-120 152 120.03 120 148.5 238.88 89.88 47, 41, 35 570 58.12
C-640D-305-120 155 111.09 111 133.5 213 75 42, 36, 30 120 57.02
C-456D-305-120 155 111.09 111 133.5 213 75 42, 36, 30 120 57.02
C-320D-256-120 155 111.07 111 132 211 75 42, 36, 30 55 57.05
C-456D-256-120 155 111.07 111 132 211 75 42, 36, 30 55 57.05
C-456D-213-120 155 111.07 111 132 211 75 42, 36, 30 0 57.05
C-320D-213-120 155 111.07 111 132 211 75 42, 36, 30 0 57.05
C-228D-213-120 155 111.07 111 132 211 75 42, 36, 30 0 57.05
C-456D-265-100 129 111.07 111 132 211 75 42, 36, 30 550 47.48
C-320D-265-100 129 111.07 111 132 211 75 42, 36, 30 550 47.48
C-320D-305-100 129 111.07 111 132 211 75 42, 36, 30 550 47.48
C-228D-213-100 129 96.08 96 113 180 63 37, 32, 27 0 48.37
C-228D-173-100 129 96.05 96 114 180 63 37, 32, 27 0 48.37
C-160D-173-100 129 96.05 96 114 180 63 37, 32, 27 0 48.37
C-320D-246-86 111 111.04 111 133 211 75 42, 36, 30 800 40.96
C-228D-246-86 111 111.04 111 133 211 75 42, 36, 30 800 40.96
C-320D-213-86 111 96.05 96 114 180 63 37, 32, 27 450 41.61
C-228D-213-86 111 96.05 96 114 180 63 37, 32, 27 450 41.61
C-160D-173-86 111 96.05 96 114 180 63 37, 32, 27 450 41.61
C-114D-119-86 111 84.05 84 93.75 150.13 53.38 32, 27, 22 115 40.98
C-320D-245-74 96 96.05 96 114 180 63 37, 32, 27 800 35.99
C-228D-200-74 96 96.05 96 114 180 63 37, 32, 27 800 35.99
C-160D-200-74 96 96.05 96 114 180 63 37, 32, 27 800 35.99
C-228D-173-74 96 84.05 84 96 152.38 53.38 32, 27, 22 450 35.49
C-160D-173-74 96 84.05 84 96 152.38 53.38 32, 27, 22 450 35.49
C-160D-143-74 96 84.05 84 93.75 150.13 53.38 32, 27, 22 300 35.49
C-114D-143-74 96 84.05 84 93.75 150.13 53.38 32, 27, 22 300 35.49
C-160D-173-64 84 84.05 84 93.75 150.13 53.38 32, 27, 22 550 31.02
C-114D-173-64 84 84.05 84 93.75 150.13 53.38 32, 27, 22 550 31.02
C-160D-143-64 84 72.06 72 84 132 45 27, 22, 17 360 30.59
C-114D-143-64 84 72.06 72 84 132 45 27, 22, 17 360 30.59
C-80D-119-64 84 64 64 74.5 116 41 24, 20, 16 0 30.85
C-160D-173-54 72 72.06 72 84 132 45 27, 22, 17 500 26.22
(Continued)
Guo, Boyun / Computer Assited Petroleum Production Engg 0750682701_chap12 Final Proof page 167 4.1.2007 2:43pm Compositor Name: SJoearun
d2x c
a¼ : amax ¼ v2 c(1 þ ): (12:1)
dt2 h
It also appears that the minimum value of acceleration is
Carrying out the differentiation for acceleration, it is
c
found that the maximum acceleration occurs when vt is amin ¼ v2 c(1 ): (12:2)
equal to zero (or an even multiple of p radians) and that h
this maximum value is If N is the number of pumping strokes per minute, then
C
x
B
Pitman arm
A
wt c Crank arm
O
w
Figure 12.7 Approximate motion of connection point between pitman arm and walking beam (Nind, 1964).
Guo, Boyun / Computer Assited Petroleum Production Engg 0750682701_chap12 Final Proof page 168 4.1.2007 2:43pm Compositor Name: SJoearun
tubing stretch. The theory in this subject has been well But because the tubing cross-sectional area At is greater
established (Nind, 1964). than the rod cross-sectional area Ar , the stretch of the
Two major sources of difference in the motion of the pol- tubing is small and is usually neglected. However, the tub-
ished rod and the plunger are elastic stretch (elongation) of the ing stretch can cause problems with wear on the casing.
rod string and overtravel. Stretch is caused by the periodic Thus, for this reason a tubing anchor is almost always used.
transfer of the fluid load from the SV to the TV and back Plunger overtravel at the bottom of the stroke is a result
again. The result is a function of the stretch of the rod string of the upward acceleration imposed on the downward-
and the tubing string. Rod string stretch is caused by the moving sucker rod elastic system. An approximation to
weight of the fluid column in the tubing coming on to the the extent of the overtravel may be obtained by consider-
rod string at the bottom of the stroke when the TV closes (this ing a sucker rod string being accelerated vertically upward
load is removed from the rod string at the top of the stroke at a rate n times the acceleration of gravity. The vertical
when the TV opens). It is apparent that the plunger stroke will force required to supply this acceleration is nWr . The
be less than the polished rod stroke length S by an amount magnitude of the rod stretch due to this force is
equal to the rod stretch. The magnitude of the rod stretch is Wr Dr
Wf Dr dlo ¼ n (ft): (12:38)
dlr ¼ , (12:36) Ar E
Ar E But the maximum acceleration term n can be written as
where SN 2 1 hc
n¼
Wf ¼ weight of fluid (lb) 70,471:2
Dr ¼ length of rod string (ft) so that Eq. (12.38) becomes
Ar ¼ cross-sectional area of rods (in:2 )
E ¼ modulus of elasticity of steel (30 106 lb=in:2 ). Wr Dr SN 2 1 hc
dlo ¼ (ft), (12:39)
Tubing stretch can be expressed by a similar equation: Ar E 70,471:2
where again the plus sign applies to conventional units and
Wf Dt the minus sign to air-balanced units.
dlt ¼ (12:37)
At E
Guo, Boyun / Computer Assited Petroleum Production Engg 0750682701_chap12 Final Proof page 172 4.1.2007 2:43pm Compositor Name: SJoearun
Let us restrict our discussion to conventional units. index and production rate. A reasonable estimate may be a
Then Eq. (12.39) becomes value that is twice the production drawdown.
Volumetric efficiency can decrease significantly due
Wr Dr SN 2 M
dlo ¼ (ft): (12:40) to the presence of free gas below the plunger. As the
Ar E 70,471:2 fluid is elevated and gas breaks out of solution, there is
Equation (12.40) can be rewritten to yield dlo in inches. Wr is a significant difference between the volumetric displace-
ment of the bottom-hole pump and the volume of the
Wr ¼ g s Ar Dr
fluid delivered to the surface. This effect is denoted by
and g S ¼ 490 lb=ft with E ¼ 30 106 lb=m2 . Eq. (12.40)
3
the shrinkage factor greater than 1.0, indicating that
becomes the bottom-hole pump must displace more fluid by some
additional percentage than the volume delivered to the
dlo ¼ 1:93 1011 D2r SN 2 M(in:), (12:41)
surface (Brown, 1980). The effect of gas on volumetric
which is the familiar Coberly expression for overtravel efficiency depends on solution–gas ratio and bottom-hole
(Coberly, 1938). pressure. Down-hole devices, called ‘‘gas anchors,’’ are
Plunger stroke is approximated using the above expres- usually installed on pumps to separate the gas from
sions as the liquid.
Sp ¼ S dlr dlt þ dlo In summary, volumetric efficiency is mainly affected by
the slippage of oil and free gas volume below plunger.
or Both effects are difficult to quantify. Pump efficiency can
12D vary over a wide range but are commonly 70–80%.
Sp ¼ S
E
1 1 SN 2 M Wr
Wf þ (in:): (12:42) 12.5.3 Power Requirements
Ar A t 70,471:2 Ar
The prime mover should be properly sized to provide
If pumping is carried out at the maximum permissible adequate power to lift the production fluid, to overcome
speed limited by Eq. (12.34), the plunger stroke becomes friction loss in the pump, in the rod string and polished
12D rod, and in the pumping unit. The power required for
Sp ¼ S lifting fluid is called ‘‘hydraulic power.’’ It is usually ex-
E
pressed in terms of net lift:
1 1 1 þ hc LWr
Wf þ (in:): (12:43) Ph ¼ 7:36 106 qg l LN , (12:45)
Ar A t 1 hc Ar
1þhc where
For the air-balanced unit, the term 1hc is replaced by its
reciprocal. Ph ¼ hydraulic power, hp
q ¼ liquid production rate, bbl/day
12.5.2 Volumetric Efficiency g l ¼ liquid specific gravity, water ¼ 1
Volumetric efficiency of the plunger mainly depends on LN ¼ net lift, ft,
the rate of slippage of oil past the pump plunger and the
solution–gas ratio under pump condition. and
Metal-to-metal plungers are commonly available with ptf
plunger-to-barrel clearance on the diameter of 0.001, LN ¼ H þ , (12:46)
0:433g l
0.002, 0.003, 0.004, and 0.005 in. Such fits are re-
ferred to as 1, 2, 3, 4, and 5, meaning the plunger where
outside diameter is 0.001 in. smaller than the barrel inside
H ¼ depth to the average fluid level in the annulus, ft
diameter. In selecting a plunger, one must consider the
ptf ¼ flowing tubing head pressure, psig.
viscosity of the oil to be pumped. A loose fit may be
acceptable for a well with high viscosity oil (low 8API The power required to overcome friction losses can be
gravity). But such a loose fit in a well with low viscosity empirically estimated as
oil may be very inefficient. Guidelines are as follows:
Pf ¼ 6:31 107 Wr SN: (12:47)
a. Low-viscosity oils (1–20 cps) can be pumped with a
plunger to barrel fit of 0.001 in. Thus, the required prime mover power can be expressed as
b. High-viscosity oils (7,400 cps) will probably carry sand Ppm ¼ Fs (Ph þ Pf ), (12:48)
in suspension so a plunger-to-barrel fit or approxi-
where Fs is a safety factor of 1.25–1.50.
mately 0.005 in. can be used.
An empirical formula has been developed that can be Example Problem 12.2 A well is pumped off (fluid
used to calculate the slippage rate, qs (bbl/day), through level is the pump depth) with a rod pump described in
the annulus between the plunger and the barrel: Example Problem 12.1. A 3-in. tubing string (3.5-in. OD,
2:9 2.995 ID) in the well is not anchored. Calculate (a)
kp db dp db þ dp Dp
qs ¼ , (12:44) expected liquid production rate (use pump volumetric
m db0:1 Lp efficiency 0.8), and (b) required prime mover power (use
where safety factor 1.35).
kp ¼ a constant
dp ¼ plunger outside diameter (in.) Solution This problem can be quickly solved using the
db ¼ barrel inside diameter (in.) program SuckerRodPumpingFlowrate&Power.xls. The
Dp ¼ differential pressure drop across plunger (psi) solution is shown in Table 12.3.
Lp ¼ length of plunger (in.)
m ¼ viscosity of oil (cp).
The value of kp is 2:77 106 to 6:36 106 depending on 12.6 Procedure for Pumping Unit Selection
field conditions. An average value is 4:17 106 . The value The following procedure can be used for selecting a pump-
of Dp may be estimated on the basis of well productivity ing unit:
Guo, Boyun / Computer Assited Petroleum Production Engg 0750682701_chap12 Final Proof page 173 4.1.2007 2:43pm Compositor Name: SJoearun
1. From the maximum anticipated fluid production 13. Calculate the ideal counterbalance effect and check it
(based on IPR) and estimated volumetric efficiency, against the counterbalance available for the unit selected.
calculate required pump displacement. 14. From the manufacturer’s literature, determine the
2. Based on well depth and pump displacement, determine position of the counterweight to obtain the ideal coun-
API rating and stroke length of the pumping unit to be terbalance effect.
used. This can be done using either Fig. 12.8 or Table 12.4. 15. On the assumption that the unit will be no more than
3. Select tubing size, plunger size, rod sizes, and pumping 5% out of counterbalance, calculate the peak torque
speed from Table 12.4. on the gear reducer and check it against the API rating
4. Calculate the fractional length of each section of the of the unit selected.
rod string. 16. Calculate hydraulic horsepower, friction horsepower,
5. Calculate the length of each section of the rod string to and brake horsepower of the prime mover. Select the
the nearest 25 ft. prime mover.
6. Calculate the acceleration factor. 17. From the manufacturer’s literature, obtain the gear
7. Determine the effective plunger stroke length. reduction ratio and unit sheave size for the unit
8. Using the estimated volumetric efficiency, determine selected, and the speed of the prime mover. From
the probable production rate and check it against the this, determine the engine sheave size to obtain the
desired production rate. desired pumping speed.
9. Calculate the dead weight of the rod string.
10. Calculate the fluid load. Example Problem 12.3 A well is to be put on a sucker
11. Determine peak polished rod load and check it against rod pump. The proposed pump setting depth is 3,500 ft.
the maximum beam load for the unit selected. The anticipated production rate is 600 bbl/day oil of 0.8
12. Calculate the maximum stress at the top of each rod specific gravity against wellhead pressure 100 psig. It is
size and check it against the maximum permissible assumed that the working liquid level is low, and a
working stress for the rods to be used. sucker rod string having a working stress of 30,000 psi is
Guo, Boyun / Computer Assited Petroleum Production Engg 0750682701_chap12 Final Proof page 174 4.1.2007 2:43pm Compositor Name: SJoearun
to be used. Select surface and subsurface equipment for the Therefore, the selected pumping unit and rod meet well
installation. Use a safety factor of 1.35 for the prime load and volume requirements.
mover power.
7. If a LUFKIN Industries C–320D–213–86 unit is
chosen, the structure unbalance is 450 lb and 4 No. 5
Solution ARO counterweights placed at the maximum position
(c in this case) on the crank will produce an effective
1. Assuming volumetric efficiency of 0.8, the required counterbalance load of 12,630 lb, that is,
pump displacement is
(37) (96:05)
(600)=(0:8) ¼ 750 bbl=day: Wc þ 450 ¼ 12,630 lb,
(37) (111)
2. Based on well depth 3,500 ft and pump displacement
which gives Wc ¼ 14,075 lb. To generate the ideal counter-
750 bbl/day, Fig. 12.8 suggests API pump size 320 unit
balance load of C ¼ 10,327 lb, the counterweights should
with 84 in. stroke, that is, a pump is selected with the
be placed on the crank at
following designation:
(10,327)(111)
r¼ (37) ¼ 31:4 in:
C-- 320D-- 213-- 86 (14,076)(96:05)
3. Table 12.4 g suggests the following:
8. The LUFKIN Industries C–320D–213–86 unit has a
Tubing size: 3 in. OD, 2.992 in. ID gear ratio of 30.12 and unit sheave sizes of 24, 30, and
Plunger size: 21⁄2 in. 44 in. are available. If a 24-in. unit sheave and a 750-
Rod size: 7⁄8 in. rpm electric motor are chosen, the diameter of the
Pumping speed: 18 spm motor sheave is
4. Table 12.1 gives d1 ¼ 96:05 in., d2 ¼ 111 in., c ¼ 37 in., (18)(30:12)(24)
and h ¼ 114 in., thus c/h ¼ 0.3246. The spreadsheet de ¼ ¼ 17:3 in:
program SuckerRodPumpingFlowRate&Power.xls gives (750)
2,500
Curve API size Stroke
Pump Displacement (bbl/day)
2,000 A 40 34
B 57 42
C 80 48
1,500 D 114 54
E 160 64
F 228 74
1,000
G 320 84
H 640 144
500
0
0 2,000 4,000 6,000 8,000 10,000 12,000
Pump Setting Depth (ft)
Figure 12.8 Sucker rod pumping unit selection chart (Kelley and Willis, 1954).
Guo, Boyun / Computer Assited Petroleum Production Engg 0750682701_chap12 Final Proof page 175 4.1.2007 2:43pm Compositor Name: SJoearun
Table 12.4 Design Data for API Sucker Rod Pumping Units
(a) Size 40 unit with 34-in. stroke
Pump Plunger Tubing Rod Pumping speed
depth (ft) size (in.) size (in.) sizes (in.) (stroke/min)
1,000–1,100 23⁄4 3 7
⁄8 24–19
1,100–1,250 21⁄2 3 7
⁄8 24–19
1,250–1,650 21⁄4 21⁄2 3
⁄4 24–19
1,650–1,900 2 21⁄2 3
⁄4 24–19
1,900–2,150 13⁄4 21⁄2 3
⁄4 24–19
2,150–3,000 11⁄2 2 5
⁄8 –3⁄4 24–19
3,000–3,700 11⁄4 2 5
⁄8 –3⁄5 22–18
5
3,700–4,000 1 2 ⁄8 –3⁄6 21–18
1,150–1,300 23⁄4 3 7
⁄8 24–19
1,300–1,450 21⁄2 3 7
⁄8 24–19
1,450–1,850 21⁄4 21⁄2 3
⁄4 24–19
1,850–2,200 2 21⁄2 3
⁄4 24–19
2,200–2,500 13⁄4 21⁄2 3
⁄4 24–19
2,500–3,400 11⁄2 2 5
⁄8 –3⁄4 23–18
3,400–4,200 11⁄4 2 5
⁄8 –3⁄5 22–17
5
4,200–5,000 1 2 ⁄8 –3⁄6 21–17
1,400–1,500 23⁄4 3 7
⁄8 24–19
1,550–1,700 21⁄2 3 7
⁄8 24–19
1,700–2,200 21⁄4 21⁄2 3
⁄4 24–19
2,200–2,600 2 21⁄2 3
⁄4 24–19
2,600–3,000 13⁄4 21⁄2 3
⁄4 23–18
3,000–4,100 11⁄2 2 5
⁄8 –3⁄4 23–19
4,100–5,000 11⁄4 2 5
⁄8 –3⁄5 21–17
5
5,000–6,000 1 2 ⁄8 –3⁄6 19–17
1,700–1,900 23⁄4 3 7
⁄8 24–19
1,900–2,100 21⁄2 3 7
⁄8 24–19
2,100–2,700 21⁄4 21⁄2 3
⁄4 24–19
2,700–3,300 2 21⁄2 3
⁄4 23–18
3,300–3,900 13⁄4 21⁄2 3
⁄4 22–17
3,900–5,100 11⁄2 2 5
⁄8 –3⁄4 21–17
5,100–6,300 11⁄4 2 5
⁄8 –3⁄5 19–16
5
6,300–7,000 1 2 ⁄8 –3⁄6 17–16
2,000–2,200 23⁄4 3 7
⁄8 24–19
2,200–2,400 21⁄2 3 7
⁄8 24–19
2,400–3,000 21⁄4 21⁄2 3
⁄4 7
– ⁄8 24–19
3,000–3,600 2 21⁄2 3
⁄4 –7⁄8 23–18
3,600–4,200 13⁄4 21⁄2 3
⁄4 –7⁄8 22–17
4,200–5,400 11⁄2 2 5
⁄8 –3⁄4 –7⁄8 21–17
5,400–6,700 11⁄4 2 5
⁄8 –3⁄4 –7⁄8 19–15
5
6,700–7,700 1 2 ⁄8 –3⁄4 –7⁄8 17–15
Guo, Boyun / Computer Assited Petroleum Production Engg 0750682701_chap12 Final Proof page 176 4.1.2007 2:43pm Compositor Name: SJoearun
2,400–2,600 23⁄4 3 7
⁄8 24–20
2,600–3,000 21⁄2 3 7
⁄8 23–18
3,000–3,700 21⁄4 21⁄2 3
⁄4 –7⁄8 22–17
3,700–4,500 2 21⁄2 3
⁄4 –7⁄8 21–16
4,500–5,200 13⁄4 21⁄2 3
⁄4 –7⁄8 19–15
5,200–6,800 11⁄2 2 5=8-- 3⁄4 –7⁄8 18–14
6,800–8,000 11⁄4 2 5=8-- 3⁄4 –7⁄8 16–13
8,000–8,500 11=16 2 5=8-- 3⁄4 –7⁄8 14–13
2,800–3,200 23⁄4 3 7
⁄8 23–18
3,200–3,600 21⁄2 3 7
⁄8 21–17
3,600–4,100 21⁄4 21⁄2 3
⁄4 –7⁄8 --1 21–17
4,100–4,800 2 21⁄2 3
⁄4 –7⁄8 --1 20–16
4,800–5,600 13⁄4 21⁄2 3
⁄4 –7⁄8 --1 19–16
5,600–6,700 11⁄2 21⁄2 3
⁄4 –7⁄8 --1 18–15
6,700–8,000 11⁄4 21⁄2 3
⁄4 –7⁄8 --1 17–13
8,000–9,500 11=16 21⁄2 3
⁄4 –7⁄8 --1 14–11
3,200–3,500 23⁄4 3 7
⁄8 –1 18–14
3,500–4,000 21⁄2 3 7
⁄8 –1 17–13
4,000–4,700 21⁄4 21⁄2 3
⁄4 –7⁄8 --1 16–13
4,700–5,700 2 21⁄2 3
⁄4 –7⁄8 --1 15–12
5,700–6,600 13⁄4 21⁄2 3
⁄4 –7⁄8 --1 14–12
6,600–8,000 11⁄2 21⁄2 3
⁄4 –7⁄8 --1 14–11
8,000–9,600 11⁄4 21⁄2 3
⁄4 –7⁄8 --1 13–10
9,600–11,000 11=16 21⁄2 3
⁄4 –7⁄8 --1 12–10
Self-aligning bear
Lugs
Winged nut
Stylus
Lugs
Plunger assembly
Pump liner
two lugs, which are attached to the winged nut, which run The use of the pump dynagraph involves pulling the
in vertical grooves in the cover tube. The stylus is mounted rods and pump from the well bath to install the instrument
on a third tube, which is free to rotate and is connected by and to recover the recording tube. Also, the dynagraph
a self-aligning bearing to the upper end of the calibrated cannot be used in a well equipped with a tubing pump.
rod. Lugs attached to the cover tube run in spiral grooves Thus, the dynagraph is more a research instrument than an
cut in the outer surface of the rotating tube. Consequently, operational device. Once there is knowledge from a dyna-
vertical motion of the plunger assembly relative to the graph, surface dynamometer cards can be interpreted.
barrel results in rotation of the third tube, and the stylus The surface, or polished rod, dynamometer is a device
cuts a horizontal line on a recording tube. that records the motion of (and its history) the polished
Any change in plunger loading causes a change in length rod during the pumping cycle. The rod string is forced by
of the section of the calibrated rod between the winged nut the pumping unit to follow a regular time versus position
supporting the recording tube and the self-aligning bearing pattern. However, the polished rod reacts with the load-
supporting the rotating tube (so that a vertical line is cut ings (on the rod string) that are imposed by the well.
on the recording tube by the stylus). When the pump is in The surface dynamometer cards record the history of
operation, the stylus traces a series of cards, one on top of the variations in loading on the polished rod during a
the other. To obtain a new series of cards, the polished rod cycle. The cards have three principal uses:
at the well head is rotated. This rotation is transmitted to
the plunger in a few pump strokes. Because the recording a. To obtain information that can be used to determine
tube is prevented from rotating by the winged nut lugs that load, torque, and horsepower changes required of the
run in the cover tube grooves, the rotation of the sucker pump equipment
rod string causes the winged nut to travel—upward or b. To improve pump operating conditions such as pump
downward depending on the direction of rotation—on speed and stroke length
the threaded calibrated rod. Upon the completion of a c. To check well conditions after installation of equipment
series of tests, the recording tube (which is 36 in. long) is to prevent or diagnose various operating problems (like
removed. pounding, etc.)
It is important to note that although the bottom-hole Surface instruments can be mechanical, hydraulic, and
dynagraph records the plunger stroke and variations in electrical. One of the most common mechanical instru-
plunger loading, no zero line is obtained. Thus, quantita- ments is a ring dynamometer installed between the hanger
tive interpretation of the cards becomes somewhat specu- bar and the polished rod clamp in such a manner as the
lative unless a pressure element is run with the dynagraph. ring may carry the entire well load. The deflection of the
Figure 12.10 shows some typical dynagraph card results. ring is proportional to the load, and this deflection is
Card (a) shows an ideal case where instantaneous valve amplified and transmitted to the recording arm by a series
actions at the top and bottom of the stroke are indicated. of levers. A stylus on the recording arm traces a record of
In general, however, some free gas is drawn into the pump the imposed loads on a waxed (or via an ink pen) paper
on the upstroke, so a period of gas compression can occur card located on a drum. The loads are obtained in terms of
on the down-stroke before the TV opens. This is shown in polished rod displacements by having the drum oscillate
card (b). Card (c) shows gas expansion during the upstroke back and forth to reflect the polished rod motion. Correct
giving a rounding of the card just as the upstroke begins. interpretation of surface dynamometer card leads to esti-
Card (d) shows fluid pounding that occurs when the well is mate of various parameter values.
almost pumped off (the pump displacement rate is higher
than the formation of potential liquid production rate).
This fluid pounding results in a rapid fall off in stress in the . Maximum and minimum PRLs can be read directly
rod string and the sudden imposed shock to the system. from the surface card (with the use of instrument cali-
Card (e) shows that the fluid pounding has progressed so bration). These data then allow for the determination of
that the mechanical shock causes oscillations in the sys- the torque, counterbalance, and horsepower require-
tem. Card (f) shows that the pump is operating at a very ments for the surface unit.
low volumetric efficiency where almost all the pump stroke . Rod stretch and contraction is shown on the surface
is being lost in gas compression and expansion (no liquid is dynamometer card. This phenomenon is reflected in
being pumped). This results in no valve action and the area the surface unit dynamometer card and is shown in
between the card nearly disappears (thus, is gas locked). Fig. 12.11a for an ideal case.
Usually, this gas-locked condition is only temporary, and . Acceleration forces cause the ideal card to rotate clock-
as liquid leaks past the plunger, the volume of liquid in the wise. The PRL is higher at the bottom of the stroke and
pump barrel increases until the TV opens and pumping lower at the top of the stroke. Thus, in Fig. 12.11b,
recommences. Point A is at the bottom of the stroke.
Figure 12.10 Pump dynagraph cards: (a) ideal card, (b) gas compression on down-stroke, (c) gas expansion on
upstroke, (d) fluid pound, (e) vibration due to fluid pound, (f) gas lock (Nind, 1964).
Guo, Boyun / Computer Assited Petroleum Production Engg 0750682701_chap12 Final Proof page 178 4.1.2007 2:43pm Compositor Name: SJoearun
. Rod vibration causes a serious complication in the in- Figure 12.12 presents a typical chart from a strain-gage
terpretation of the surface card. This is result of the type of dynamometer measured for a conventional unit
closing of the TV and the ‘‘pickup’’ of the fluid load operated with a 74-in. stroke at 15.4 strokes per minute. It
by the rod string. This is, of course, the fluid pounding. shows the history of the load on the polished rod as a
This phenomenon sets up damped oscillation (longitu- function of time (this is for a well 825 ft in depth with a
dinal and bending) in the rod string. These oscillations No. 86 three-tapered rod string). Figure 12.13 reproduces
result in waves moving from one end of the rod string to the data in Fig. 12.12 in a load versus displacement dia-
the other. Because the polished rod moves slower near gram. In the surface chart, we can see the peak load of
the top and bottom of the strokes, these stress (or load) 22,649 lb (which is 28,800 psi at the top of the 1-in. rod) in
fluctuations due to vibrations tend to show up more Fig. 12.13a. In Fig. 12.13b, we see the peak load of
prominently at those locations on the cards. Figure 17,800 lb (which is 29,600 psi at the top of the 7⁄8 -in. rod).
12.11c shows typical dynamometer card with vibrations In Fig. 12.13c, we see the peak load of 13,400 lb (which
of the rod string. is 30,300 psi at the top of the 3⁄4 -in. rod). In Fig. 12.13d is
Rod stretch
Rod
contraction
Wr-Wrb
Zero line
(a)
Zero line
A
B
C
F Wr-Wrb+Wf
Wr-Wrb
Figure 12.11 Surface dynamometer card: (a) ideal card (stretch and contraction), (b) ideal card (acceleration),
(c) three typical cards (Nind, 1964).
24,000
Polished Rod Load (lb)
21,000
18,000
15,000
12,000
9,000
6,000
3,000
0
0
Displacement (ft)
Polished Rod
8
0 1 2 3 4 5 6 7 8 9
Time (sec)
28,000
24,000
(a)
20,000
(b)
16,000
Load (lb)
(c)
12,000
8,000
4,000 (d)
−4,000
8 7 6 5 4 3 2 1 0 −1 −2 −3 −4
Displacement (ft)
Figure 12.13 Surface to down hole cards derived from surface dynamometer card.
the dynagraph card at the plunger itself. This card indicates 12.3 Use your knowledge of kinematics to prove that for
gross pump stroke of 7.1 ft, a net liquid stroke of 4.6 ft, and Class I lever systems,
a fluid load of Wf ¼ 3,200 lb. The shape of the pump card,
a. the polished rod will travel faster in down stroke
Fig. 12.13d, indicates some down-hole gas compression.
than in upstroke if the distance between crank-
The shape also indicates that the tubing anchor is holding
shaft and the center of Sampson post is less than
properly. A liquid displacement rate of 200 bbl/day is cal-
dimension d1 .
culated and, compared to the surface measured production
b. the polished rod will travel faster in up stroke than
of 184 bbl/day, indicated no serious tubing flowing leak.
in down stroke if the distance between crankshaft
The negative in Fig. 12.13d is the buoyancy of the rod
and the center of Sampson post is greater than
string.
dimension d1 .
The information derived from the dynamometer card
(dynagraph) can be used for evaluation of pump perfor- 12.4 Derive a formula for calculating the effective di-
mance and troubleshooting of pumping systems. This sub- ameter of a tapered rod string.
ject is thoroughly addressed by Brown (1980).\ 12.5 Derive formulas for calculating length fractions of
equal-top-rod-stress tapered rod strings for (a) two-
sized rod strings, (b) three-sized rod strings, and
Summary (c) four-sized rod strings. Plot size fractions for
This chapter presents the principles of sucker rod pumping each case as a function of plunger area.
systems and illustrates a procedure for selecting components 12.6 A tapered rod string consists of sections of 5⁄8 - and 1⁄2 -
of rod pumping systems. Major tasks include calculations of in. rods and a 2-in. plunger. Use the formulas from
polished rod load, peak torque, stresses in the rod string, Problem 12.5 to calculate length fraction of each size
pump deliverability, and counterweight placement. Opti- of rod.
mization of existing pumping systems is left to Chapter 18. 12.7 A tapered rod string consists of sections of 3⁄4 -, 5⁄8 -,
and 1⁄2 -in. rods and a 13⁄4 -in. plunger. Use the for-
mulas from Problem 12.5 to calculate length fraction
of each size of rod.
References
12.8 The following geometry dimensions are for the
brown, k.e. The Technology of Artificial Lift Methods, pumping unit C–80D–133–48:
Vol. 2a. Tulsa, OK: Petroleum Publishing Co., 1980. d1 ¼ 64 in.
coberly, c.j. Problems in modern deep-well pumping. Oil d2 ¼ 64 in.
Gas J. May 12, 1938. c ¼ 24 in.
golan, m. and whitson, c.h. Well Performance, 2nd edi- h ¼ 74.5 in.
tion. Englewood Cliffs: Prentice Hall, 1991. Can this unit be used with a 2-in. plunger and 3⁄4 -in.
nind, t.e.w. Principles of Oil Well Production. New York: rods to lift 30 8API gravity crude (formation volume
McGraw-Hill Book Co., New York, 1964. factor 1.25 rb/stb) at depth of 2,000 ft? If yes, what is
the required counter-balance load?
12.9 The following geometry dimensions are for the
Problems pumping unit C–320D–256–120:
d1 ¼ 111:07 in.
12.1 If the dimensions d1 , d2 , and c take the same values d2 ¼ 155 in.
for both conventional unit (Class I lever system) and c ¼ 42 in.
air-balanced unit (Class III lever system), how differ- h ¼ 132 in.
ent will their polished rod strokes length be?
12.2 What are the advantages of the Lufkin Mark II and Can this unit be used with a 21⁄2 -in. plunger and 3⁄4 -,
7
air-balanced units in comparison with conventional ⁄8 -, 1-in. tapered rod string to lift 22 8API gravity
units? crude (formation volume factor 1.22 rb/stb) at a
Guo, Boyun / Computer Assited Petroleum Production Engg 0750682701_chap12 Final Proof page 180 4.1.2007 2:43pm Compositor Name: SJoearun
depth of 3,000 ft? If yes, what is the required coun- pated production rate is 500 bbl/day oil of 40 8API
ter-balance load? gravity against wellhead pressure 150 psig. It is as-
sumed that the working liquid level is low, and a
12.10 A well is pumped off with a rod pump described
sucker rod string having a working stress of
in Problem 12.8. A 21⁄2 -in. tubing string (2.875-in.
30,000 psi is to be used. Select surface and subsur-
OD, 2.441 ID) in the well is not anchored. Calculate
face equipment for the installation. Use a safety
(a) expected liquid production rate (use pump volu-
factor of 1.40 for prime mover power.
metric efficiency 0.80) and (b) required prime mover
12.13 A well is to be put on a sucker rod pump. The
power (use safety factor 1.3).
proposed pump setting depth is 4,000 ft. The antici-
12.11 A well is pumped with a rod pump described in
pated production rate is 550 bbl/day oil of 35 8API
Problem 12.9 to a liquid level of 2,800 ft. A 3-in.
gravity against wellhead pressure 120 psig. It is as-
tubing string (31⁄2 -in. OD, 2.995-in. ID) in the well
sumed that working liquid level will be about
is anchored. Calculate (a) expected liquid production
3,000 ft, and a sucker rod string having a working
rate (use pump volumetric efficiency 0.85) and (b)
stress of 30,000 psi is to be used. Select surface and
required prime mover power (use safety factor 1.4).
subsurface equipment for the installation. Use a
12.12 A well is to be put on a sucker rod pump. The
safety factor of 1.30 for prime mover power.
proposed pump setting depth is 4,500 ft. The antici-