MP14 / MP214 / MP314 Do not use the equipment if there is any mechanical

selec Operating Instructions damage.


Ensure that the equipment is supplied with correct
OP371-V01

voltage.
CAUTION :
1. Read complete instructions prior to installation and
operation of the unit.
2. Risk of electric shock.
3. The equipment in its installed state must not come in
(48 x 96) (72 x 72) (96 x 96) close proximity to any heating sources, caustic vapors,
oils, steam, or other unwanted process by products.
SPECIFICATIONS
WIRING GUIDELINES
Display : 4 Digit, 7 Segment LED Display,
WARNING :
0.56 inch digit height
Display Range : -1.000 to +1.000 1. To prevent the risk of electric shock, power supply to the
Wiring Input : 1 Ø - 2 wire equipment must be kept OFF while doing the wiring
Errors Indication arrangement.
Current absent : (Blinking) 2. Wiring shall be done strictly according to the terminal
CT reverse : and power factor displays layout. Confirm that all connections are correct.
alternately
3. Use lugged terminals.
Resolution : 0.001
Current Input : 0.25-6A(AC) 4. To reduce electromagnetic interference use of wires with
Measurement : ±0.5% ±1digit adequate ratings and twists of the same in equal size shall
Accuracy be made with shortest connections.
Measuring / Supply : 240V AC(± 20%), 50/60Hz 5. Layout of connecting cables shall be away from any
Voltage 110V AC(± 20%), 50/60Hz internal EMI source.
Power Consumption : 5VA max.
6. Cable used for connection to power source, must have a
Environmental Conditions
Temperature : Operating : -10°C to 55°C cross section of 0.5mm2 to 2.5mm2 (20 to 14AWG ; 750C
Storage : -20°C to 75°C (min)). These wires shall have current carrying capacity of
Humidity : Up to 95% RH(non condensing) 6A.
Altitude : Up to 2000 meters 7. Copper cable should be used (Stranded or Single core
Pollution degree : II
cable).
Installation Category : II (300V)
Mounting : Panel Mounting 8. Before attempting work on device, ensure absence of
Protection Class : II voltages using appropriate voltage detection device.
Weight : MP14 : 170gms
MP214 : 180gms
MP314 : 180gms INSTALLATION GUIDELINES
CAUTION :
ORDER CODE INFORMATION
1. This equipment, being built-in-type, normally becomes a
Product Supply Certification part of main control panel and in such case the terminals
R

LISTED
do not remain accessible to the end user after installation
and internal wiring.
MP14 240V AC (±20%), 50 / 60Hz
2. Conductors must not come in contact with the internal
MP14-110V 110V AC (±20%), 60Hz circuitry of the equipment or else it may lead to a safety
240V AC (±20%), 50 / 60Hz
hazard that may in turn endanger life or cause
MP14-CU
electrical shock to the operator.
MP14-110V-CU 110V AC (±20%), 60Hz 3. Circuit breaker or mains switch must be installed
MP214 240V AC (±20%), 50 / 60Hz between power source and supply terminals to facilitate
power 'ON' or ‘OFF’ function. However this switch or
MP314 240V AC (±20%), 50 / 60Hz
breaker must be installed in a convenient position
MP314-110V 110V AC (±20%), 60Hz normally accessible to the operator.
4. Before disconnecting the secondary of the external
current transformer from the equipment, make sure that
SAFETY PRECAUTIONS the current transformer is short circuited to avoid risk of
All safety related codifications, symbols and electrical shock and injury.
instructions that appear in this operating manual or on the 5. The equipment shall not be installed in environmental
equipment must be strictly followed to ensure the safety conditions other than those mentioned in this manual.
of the operating personnel as well as the instrument. 6. The equipment does not have a built-in-type fuse.
If the equipment is not used in a manner specified by Installation of external fuse of rating 275V AC / 0.5Amp
the manufacturer it might impair the protection provided for electrical circuitry / battery is highly recommended.
by the equipment.
Doc. name : OP INST MP14/MP214/MP314 OP371-V01(Page 1 of 2)
MECHANICAL INSTALLATION
For installing the meter
1. Prepare the panel cutout with proper dimensions as
shown below.
2. Push the meter into the panel cutout. Secure the meter
in its place by pushing the clamp on the rear side. The
clamps must be secured in diagonally opposite slots.
3. For proper sealing, tighten the screws evenly with
required torque.
Terminal screw tightening torque :
0.68 N-m to 0.79 N-m (6.018 In-Lb to 6.992 In-Lb)
Screw clamp tightening torque : 0.1N-m (0.885 Lb-inch)
Outline Panel cutout
Dimensions (in mm) Dimensions (in mm)
MP14

44.8
52

46

102 50 92
4.5
MP214

67.5

67.5
76

50 67.5
76 3.5
MP314

91

92
99

46 92
99 5

MAINTENANCE
1. The equipment should be cleaned regularly to avoid
blockage of ventilating parts.
2. Clean the equipment with a clean dry or damp cloth.
Do not useany cleaning agent other than water.

TERMINAL CONNECTIONS
MP14 / MP214 / MP314

P1 P2 L
O
A
D
N 1 2 L S2 3 4 S1

WIRING DIAGRAM

MP14 / MP214 / MP314

N L S2 S1

# (Specifications subject to change as development is a continuous process.)


L
N o
R/Y/B A Selec Controls Pvt. Ltd., India
D
Factory Address :
EL-27/1, Electronic Zone, TTC Industrial Area,
# All fuse types : 0.5A class CC UL type ; 0.5A fast acting 600V MIDC, Mahape, Navi Mumbai - 400 710, INDIA.
Tel. No. : +91-22-28476443 / 1882
Fax No. : +91-22-28471733 I Toll free : 1800 227 353
Website: www.selec.com I Email: sales@selec.com
Doc. name : OP INST MP14/MP214/MP314 OP371-V01(Page 2 of 2)