Panel Thermostat: 7T.81.0.000.240x 7T.81.0.000.230x
Panel Thermostat: 7T.81.0.000.240x 7T.81.0.000.230x
Panel Thermostat: 7T.81.0.000.240x 7T.81.0.000.230x
Max
Min
Heating control - Should the panel temperature fall below the (minimum)
set temperature the contact will close to call for heat. The contact will open
when this set temperature is exceeded.
Ventilation control - Should the panel temperature exceed the (maximum) set
temperature then the contact will close to call for cooling. The contact will open
For outline drawing see page 2 when the temperature falls below this set temperature. G
Contact specification
Contact configuration 1 NC 1 NO
Rated current/Maximum peak current A 10/20 10/20
Rated voltage/
250/250 250/250
Maximum switching voltage V AC
Rated load AC1 VA 2500 2500
Rated load AC15 (230 V AC) VA 250 250
Single phase motor rating AC3 (230 V AC)kW 1.1 1.1
Breaking capacity DC1: 30/110/220 V A 1/0.3/0.15 1/0.3/0.15
Minimum switching load mW (V/mA) 500 (12/10) 500 (12/10)
Standard contact material AgNi AgNi
Temperature setting range
Setting range (ventilation) °C — –20…+40 +0…+60
Switch temperature differential K — 7 ± 4
Setting range (heating) °C –20…+40 +0…+60 —
Switch temperature differential K 7 ± 4 —
Technical data
Electrical life at rated load AC1 cycles 100 · 103 100 · 103
Ambient temperature range °C –45…+80 –45…+80
Protection category IP 20 IP 20
Approvals (according to type)
IX-2016, www.findernet.com
1
7T 7T SERIES
SERIES Panel Thermostat
Ordering information
Example: 7T Series, thermostat for ventilation control, contact activates ventilation should the panel temperature exceed the set value (max+60 °C),
35 mm rail (EN 60715) mount.
7 T . 8 1 . 0 . 0 0 0 . 2 3 0 3
Series Control function
Type (Temperature only)
8 = 35 mm rail (EN 60715) mount 1 = (–20…+40)°C
3 = (0…+60)°C
No. of contacts
1 = 1 contact Contact configuration
3 = 1 NO contact
Voltage type
4 = 1 NC contact
0 = No operating voltage required
Monitoring function
Rated operating voltage
2 = Temperature, adjustable
000 = No operating voltage required
Technical data
Insulation
Dielectric strength between open contacts V AC 500
Other data
Screw torque Nm 0.5 0.5
Max. wire size solid cable stranded cable
2
mm 1 x 2.5 1 x 1.5
AWG 1 x 12 1 x 16
G
Outline drawings
7T.81
Screw terminal
IX-2016, www.findernet.com