CCIE Data Center Storage Networking Fibre Channel Switching Configuration
CCIE Data Center Storage Networking Fibre Channel Switching Configuration
CCIE Data Center Storage Networking Fibre Channel Switching Configuration
Storage Networking
Copyright © www.INE.com
Virtual SANs (VSANs)
• Use to segment Fabric Services into logical “SAN Islands”
– FLOGI, FC Domain, FC Name Server, Zoning, Aliases, etc.
• Configured as…
– vsan database
– vsan 10
– vsan 10 interface fc1/1
• VSANs and EISLs
– All VSANs allowed on trunk ports by default
– Remotely un-configured VSANs automatically “pruned” off of trunks
• Similar to Ethernet Bridge Assurance
– To avoid merging fabrics, VSANs should be pruned manually
• switchport trunk allowed vsan
Copyright © www.INE.com
FC Fabric Services
• Fibre Channel networks are connection oriented
– Nodes must first register with the control plane of the fabric before sending
any traffic
• FC Fabric Services include…
– FC Domain
• Principle Switch Election & assignment of Domain IDs
– FSPF
• Fabric Routing between Domain IDs
– FLOGI
• End station registers with the fabric and are assigned FCID
– FC Name Services / Directory Services
• Distributes FCID to pWWN/WWPN mappings through Fabric
– Zoning
• Controls which Initiators can talk to which Targets
Copyright © www.INE.com
FC Domain
• Principle Switch assigns Domain IDs to Fabric
• PS Election
– Based on lowest priority and SWWN
– Modified as fcdomain priority 1 vsan 1
• Domain ID selection
– Dynamic from PS by default
– Static as fcdomain domain 0x51 [preferred | static]
• Preferred requests Domain ID but will join without the assignment
• Static requests Domain ID and isolates itself without the
assignment
Copyright © www.INE.com
FC Domain
• FC Domain process restart
– Graceful as fcdomain restart vsan 1
– Forced as fcdomain restart disruptive vsan 1
• Not recommended
• Verified as…
– show fcdomain [vsan]
– show fcdomain domain-list [vsan]
Copyright © www.INE.com
Q&A
Copyright © www.INE.com