Datasheet: L6D Load Cell: Specifications
Datasheet: L6D Load Cell: Specifications
Datasheet: L6D Load Cell: Specifications
Specifications:
1
Accuracy class C3D OIML R60 C3 OIML R60 C4 OIML R60 C5
Output sensitivity mV/V 1.8 ± 0.2 2.0 ± 0.2
1
Maximum capacity ( Emax ) kg 2.5 3, 5, 6, 8, 10, 15, 20, 30, 35, 40, 50
Maximum number of load cell intervals ( nLC ) 3000 3000 4000 5000
Ratio of minimum LC verification interval Y = Emax / vmin 7000 10000 15000 20000
Ratio of minimum dead load output return Z =Emax/2 * DR 3000 6000 7500
Combined Error %FS ≤ ± 0.0200 ≤ ± 0.0175 ≤ ± 0.0140
Minimum dead load kg 0
Safe overload of Emax 150 %
Ultimate overload of Emax 300 %
Zero balance of FS ≤ ± 2.0 %
Excitation, recommended voltage V 5 ~ 12
Excitation maximum V 18
Terminal resistance, input Ω 409 ± 6
Terminal resistance, output Ω 350 ± 3
Insulation impedance MΩ ≥ 5000 ( at 50VDC )
Temperature range, compensated °C -10 ~+40
Temperature range, operating °C -35 ~ +65
Element material Aluminium
Recommended torque on fixation bolts Nm < 30kg: 6 ≥30kg:10
Ingress Protection (according to EN 60529) IP65
Note 1: 2.5kg is not OIML approved
Please visit our website WWW.ZEMIC.NL for the most actual information Nr. 2011.03 L6D Rev6