Location via proxy:   [ UP ]  
[Report a bug]   [Manage cookies]                

Rockwool Architectural Binder

Download as pdf or txt
Download as pdf or txt
You are on page 1of 76

Click here for Click here for Click here for

Commercial Residential Roofing


Applications Applications Applications

The world leader in stone wool insulation


Le leader mondial de l’isolation en laine de roche
Commercial
Applications
Building Insulation CURTAINROCK 40 ®

Product Overview Technical Data Sheet

CAVITYROCK ®
CURTAINROCK 80 ®

Cavity Wall and Technical Data Sheet


Rainscreen Brochure
ROXUL SAFE ™

CAVITYROCK ®
Technical Data Sheet
Technical Data Sheet
ROCKBOARD ®

COMFORTBATT ®
Multipurpose Board
Technical Data Sheet Brochure

COMFORTBOARD 110 ™
ROCKBOARD 40 ®

Thermal Insulated Technical Data Sheet


Sheathing Brochure
ROCKBOARD 60 ®

COMFORTBOARD 110 ™
Technical Data Sheet
Technical Data Sheet
ROCKBOARD 80 ®

ROCKWOOL AFB ®
Technical Data Sheet
Acoustical Fire Batt Brochure
ROXUL SAFE 55 & 65 &

ROCKWOOL AFB ®
ROCKWOOL PLUS MB ™

Technical Data Sheet Metal Buildings Brochure

ROCKWOOL AFB evo ™


ROXUL SAFE 55™

Technical Data Sheet Technical Data Sheet

CURTAINROCK & ROXUL SAFE


® ™
ROXUL SAFE 65™

Perimeter Fire Containment Technical Data Sheet


Systems Brochure
ROCKWOOL PLUS MB ™

CURTAINROCK ®
Technical Data Sheet
Technical Data Sheet

Click on any of the above brochures or data


sheets to be directed to that specific document.

Visit www.rockwool.com for our full


Product Documentation Library.
Density pcf R-value Per Corrosive
Products Standard Thickness Dimensions (WxL)
(Kg/m3) Inch
Fire Acoustic (at 3” Thickness)
Resistance
Compliance

ASTM E 136 & ASTM E 84 ASTM C 423 ASTM


Interior Wall CAN/ULC S114 (UL 723) 250Hz | 500Hz | 1000Hz | 2000Hz C 423 NRC
ASTM C 665 ASTM C 665 CAN/ULC S702 ASTM C 553 UL Design Nos.

1”-4”, 0.5” 2.5 (40) >= 3”,


AFB® 16”x48”, 24”x48” N/A Non-combustible Complies 0.96 | 1.18 | 1.07 | 1.05 1.05 Pass Type 1, Complies Type 1, Complies Type 7, Complies Consult UL/ULC Listings
increments, 5”, 6” 2.8 (45) < 3”

1”-4”, 0.5” 2.5(40) >= 3”,


AFB evoTM 16”x48”,24”x48” N/A Non-combustible Complies 0.96 | 1.18 | 1.07 | 1.05 1.05 Pass Type 1, Complies Type 1, Complies Type 7, Complies Consult UL/ULC Listings
increments, 5”, 6” 2.8 (45) < 3”

ASTM E 136 & ASTM E 84 ASTM C 423 ASTM


Exterior Wall Batt CAN/ULC S114 (UL 723) 250Hz | 500Hz | 1000Hz | 2000Hz C 423 NRC
ASTM C 665 ASTM C 665 CAN/ULC S702 ASTM C 553 UL Design Nos.

COMFORTBATT® 2.5”, 3.5”, 6” (CAN) R10-R24 (CAN)


16.25"x48", 24.25"x48 >2 (>32) Non-combustible Complies N/A N/A Pass Type 1, Complies Type 1, Complies N/A N/A
Steel Stud 2.5”, 3.5”, 6”, 7.25” (USA) R10-R30 (USA)

COMFORTBATT ®
3.5”, 5.5”, 7.25”, 8” (CAN) R14-R32 (CAN)
15.25"x47", 23"x47" >2 (>32) Non-combustible Complies N/A N/A N/A Type 1, Complies Type 1, Complies N/A N/A
Wood Stud 3.5”, 5.5”, 7.25” (USA) R15-R30 (USA)

Corrosive Moisture Fungi Vapor


Fire Acoustic (at 3” Thickness) Compliance
Resistance Resistance Resistance Permeability

ASTM E 136 & ASTM E 84 ASTM C 423 ASTM


Exterior Wall Rainscreen & Cavity Wall CAN/ULC S114 (UL 723) 250Hz | 500Hz | 1000Hz | 2000Hz C 423 NRC
ASTM C 665 ASTM C 1104 ASTM C 1338 ASTM E 96 ASTM C 612

6.2 / 4.1 (100 / 65) 4.3


1” - 4",
CAVITYROCK® 16”x48”, 24”x48” 5.3 (85) 1”-1.5”, Non-combustible Complies 0.93 | 0.88 | 0.84 | 0.90 0.90 Pass 0.03% Zero Growth 27 perms Type IVB, Complies
0.5" increments, 5”, 6"
4.4 (70) 2”

Corrosive Moisture Compressive Vapor


Fire Acoustic (at 2” Thickness) Compliance
Resistance Resistance Strength (psf) Permeability

ASTM E 136 & ASTM E 84 ASTM C 423 ASTM ASTM C 165


Insulated Sheathing for Continuous Insulation CAN/ULC S114 (UL 723) 250Hz | 500Hz | 1000Hz | 2000Hz C 423 NRC
ASTM C 665 ASTM C 1104
@10% | @25%
ASTM E 96 ASTM C 612

COMFORTBOARDTM 110 1", 1.25", 2", 2.5", 3" 24"x48", 48"x72" 11 (176) 4 Non-combustible* Complies 0.71 | 0.85 | 0.90 | 0.96 0.85 Pass 0.28% 584 | 1566 35 perm Type IVB, Complies

48”x24”, 48”x36”,
COMFORTBOARDTM 80 1.25”, 1.5”, 2”, 2.5”, 3” 8 (128) 4 Non-combustible* Complies 0.78 | 0.90 | 0.97 | 0.97 0.90 Pass 0.05% 439 | 1065 31 perm Type IVB, Complies
48”x72”, 48”x96”

Corrosive Moisture
Fire Acoustic (at 3” Thickness) Compliance
Resistance Resistance

ASTM E 136 & ASTM E 84 ASTM C 423 ASTM


Curtain Wall Systems CAN/ULC S114 (UL 723) 250Hz | 500Hz | 1000Hz | 2000Hz C 423 NRC
ASTM C 665 ASTM C 1104 UL/ULC Design Nos. ASTM C 612

CURTAINROCK® 1", 1.5", 2", 3", 4", 5" 24"x48" 3.5 (56) 4.2 Non-combustible Complies 0.95 | 1.14 | 1.01 | 1.03 1.05 Pass 0.01% Consult UL/ULC Listings Type IVB, Complies

CURTAINROCK® 40 2", 3", 4" 24"x48", 48"x72" 4 (64) Nominal 4.3 Non-combustible Complies N/A N/A Pass 0.01% Consult UL/ULC Listings Type IVB, Complies

CURTAINROCK® 80 1”, 2”, 3”, 4” 24"x48", 48"x72" 8 (128) Nominal 4.3 Non-combustible Complies N/A N/A Pass 0.04% Consult UL/ULC Listings Type IVB, Complies

ROXUL SAFETM 2", 3”, 4" 24"x48" 4.5 (72) N/A Non-combustible Complies N/A N/A Pass 0.04% Consult UL/ULC Listings Type IVA, Complies

Corrosive Moisture
Fire Acoustic (at 3” Thickness) Alternative Solutions Compliance
Resistance Resistance

ASTM E 136 & ASTM E 84 ASTM C 423 ASTM


Multi-Purpose Boards CAN/ULC S114 (UL 723) 250Hz | 500Hz | 1000Hz | 2000Hz C 423 NRC
ASTM C 665 ASTM C 1104 Facing Options ASTM C 612

ROCKBOARD® 40 2", 2.5”, 3", 4" 24"x48" 4 (64) 4.2 Non-combustible Complies 0.95 | 1.14 | 1.01 | 1.03 1.05 Pass 0.03% Foil Faced, Black Mat Type IVA, Complies

ROCKBOARD® 60 2", 3", 3.5”, 4" 24"x48" 6 (96) 4.3 Non-combustible* Complies 0.89 | 1.04 | 0.98 | 1.01 1.00 Pass 0.07% Foil Faced, Black Mat Type IVB, Complies

ROCKBOARD® 80 1”, 1.5”, 2”, 3”, 4” 24"x48" 8 (128) 4 Non-combustible* Complies 0.82 | 0.89 | 0.94 | 1.00 0.90 Pass 0.05% Foil Faced, Black Mat Type IVB, Complies

Corrosive Moisture DISCLAIMER AND LIMITATION OF LIABILITY: The statements


Fire Compliance and data contained in this brochure are for general
Resistance Resistance
information purposes ONLY. They are NOT specific technical
recommendations as to any particular design or application
ASTM E 136 & ASTM E 84 and the ultimate determination as to product suitability is
Metal Building CAN/ULC S114 (UL 723)
ASTM C 665 ASTM C 1104 UL Design Nos. ASTM C 612 ASTM C 553 the sole responsibility of the installer or end user. Although
the information contained herein, including ROCKWOOL
product descriptions, is believed to be correct at the time of
24"x48", 31.5"x48", Type IVB,
ROXUL SAFETM 65 3" 6 (96) Nominal 4.2 Non-combustible Complies Pass 0.04% Consult UL/ULC Listings N/A publication, accuracy cannot be guaranteed. ROCKWOOL
32"x48" Complies fully reserves the right to make product specification changes,
without notice or obligation, and to modify or discontinue any
of its products at any time. In no event shall ROCKWOOL be
24"x48", 31.5"x48", Type IVB,
ROXUL SAFETM 55 4" 4.5 (72) Nominal 4.2 Non-combustible Complies Pass 0.04% Consult UL/ULC Listings N/A liable for any direct, indirect, or consequential damages of
32"x48" Complies any kind arising from information contained in this brochure,
including, but not limited to, claims for loss of profits,
2"-4", business interruption, or damages to business reputation. This
ROCKWOOL PLUSTM MB 24"x48" 2 (32) 4 Non-combustible Complies Pass 0.03% N/A N/A Type I, II, III limitation of liability shall apply to all claims whether those
0.5” increments, 5”, 6”
claims are based in contract, tort, or any legal cause of action.

*Applies to CAN/ULC S114 only.

Return to Commercial Applications


HIGH-PERFORMANCE RAINSCREEN SYSTEMS

CAVITYROCK
®

and COMFORTBATT
®

Effective Insulation Solutions – The Future


of High-Performance Rainscreen Systems

Return to Commercial Applications


The Future of High-Performance Rainscreen Systems

✔ Stable Long-Term Thermal


This unique vapor permeable
Resistance
Over 60,000 sq. ft. of ROCKWOOL CAVITYROCK® was installed in the Rush University Medical Center’s 14-story hospital in quality of ROCKWOOL’s
✔ Sound Absorbent
Chicago. (Also shown on front cover.) Rush is seeking gold leadership in energy and environment design (LEED®) certification
for the new hospital. “From the beginning, it’s been designed to use water and energy efficiently and keep down waste. We’re
curtain wall insulation allows
using environmentally responsible building materials, and we’re recycling as much as we possibly can,” says Mick Zdeblick, vice for anResistant
✔ Fire increased potential for
president, campus transformation.​*
drying without trapping
✔ Vapor Permeable
*http://transforming.rush.edu water in the wall assembly.
✔ Continuous Insulation

The Building Envelope Design using


✔ Environmentally Sustainable

ROCKWOOL [BEDR ] Wall System Philosophy ™

Evolution of Rainscreen Systems ROCKWOOL insulation will not slump in stud spacing
The primary functions of a wall system* – to protect, causing gaps, will not expand or contract due to
facilitate, and/or provide heat, air, rain penetration, temperature variances in the rainscreen system, nor is
movement of moisture, fire, durability, noise, light, it adversely affected by the presence of moisture in the The BEDR Wall Rainscreen System

strength, and aesthetics – have not changed over the past system, all of which contribute to the optimal thermal The ROCKWOOL BEDR Wall Rainsceen System

40 years. The same cannot be said for the components performance of a building envelope. ROCKWOOL comprises ROCKWOOL thermal batt insulation in the
and design of cavity wall systems, which have undergone insulation is made from stone and is non-combustible exterior stud wall cavity (up to 6”), combined with a
a significant transformation in North America. with an extremely high melting point, making it the high-density, semi-rigid ROCKWOOL insulation board
safest insulation when compared to both fiberglass and (up to 6”) in the external cavity.
This change in design requirements is a result of the foam plastics.
increased code requirements that are based on changing ROCKWOOL insulation within the exterior wall stud
ASHRAE standards. Increasing requirements also ask cavity and the external cavity offers superior long-term
for continuous insulation (c.i.) to meet the R-value and thermal efficiency, fire resistance, moisture control, and
U-value requirements of ASHRAE 90.1. acoustic performance.

ROCKWOOL is at the forefront of developing wall


systems that meet this call for higher energy efficiency,
sustainability, durability and better overall performance in BEDR Rainscreen System Zone 4-8

commercial buildings. Components: Cladding, Air space, CAVITYROCK , ®

*Canadian Building Digest, NRC National Research Council Canada Permeable air barrier, Exterior gypsum board sheathing,
Steel stud, COMFORTBATT , Vapor barrier, Gypsum board.
®

The ROCKWOOL Difference Note: In climates dominated by heating degree days (HDDs), the blue air barrier
The R-value of ROCKWOOL insulation does not change material should be vapor permeable.
over time because stone wool is not produced with
blowing agents, which off-gas and result in lower thermal
performance. Not only is the thermal performance of
ROCKWOOL insulation maintained over its lifetime,
but the wall system’s thermal performance is maintained
because ROCKWOOL products are dimensionally stable. 1970 1990 2010
A combination of
All insulation in All insulation in
insulation within the
the stud wall with the cavity with no
steel stud and cavity.
building paper on insulation in the
Vapor permeable air
the exterior. steel stud. High-
barriers used.
No cavity wall performance air/vapor
insulation used. barriers used.

ROCKWOOL Group ROCKWOOL Group


5 6
Return to Commercial Applications
ROCKWOOL COMFORTBATT and CAVITYROCK –BEDR ® ® ™
Why this BEDR Wall is a Better Wall? ™

Wall Combination

ROCKWOOL COMFORTBATT ®
Dimensional Stability Long-Term Thermal Performance
The COMFORTBATT product line is a non-combustible,
®
The dimensional stability of an insulation material is As the building industry seeks new and innovative
semi-rigid batt insulation range that is designed for necessary for the faultless function of an insulation solutions that are truly energy efficient, ROCKWOOL
exterior steel stud wall applications. system. Dimensional changes in materials vary according leads the way in developing wall systems with excellent
to their physical properties. Thermal expansion long-term thermal performance. This is the result of two
COMFORTBATT products are available from 2.5” to 8”
®
coefficients express the rate at which materials shrink or inherent properties in its BEDR insulating systems – lack

in thickness and have standard R-values ranging from R10 expand when cooled or heated. ROCKWOOL insulation of thermal loss due to dimensional changes, and the
to R32. Stone wool batt insulation will not slump inside has a much smaller thermal expansion coefficient than insulation’s ability to repel water, which aids in the control
the wall cavity over time. COMFORTBATT products also
®
organic insulation materials such as foam plastics. of heat loss and gain.
provide excellent sound absorption characteristics.
Poor dimensional stability can cause shrinking, expansion, The use of CAVITYROCK as a continuous insulation (c.i.)
®

and buckling of a system's insulation. These actions results in a BEDR wall with higher effective thermal

can lead to thermal bridging, waterproofing breaches, resistance values than foam plastics.
and unpredictable insulation performance.

Expansion Expansion at Temp.


Material Type Co-Efficient Difference of 50°C or
10-6 m/m˚C 90°F over 10 m./33 ft.

Stone Wool 5.5 3

Concrete 12 6

Steel 12 6
ROCKWOOL CAVITYROCK ®

ROCKWOOL CAVITYROCK products are non-combustible,


®
Expanded Polystyrene 70 35
semi-rigid insulation boards specifically engineered for
exterior cavity wall and rainscreen applications. Extruded Polystyrene 80 40

CAVITYROCK is available in sizes from 1” to 6” in


®

Polyurethane 100 50
thickness, in .5” increments. The products available in 1” to
2” thicknesses are mono-density solutions offering thermal
Polyisocyanurate 120 60
resistance of R4.2/in. These products are suggested when
lower exterior thermal resistance is required.
ROCKWOOL CAVITYROCK® products are
compatible with numerous framing systems The CAVITYROCK products available from 2.5” to 6”
®

and cladding attachment systems. To learn thicknesses are produced with dual-density technology Water Vapor Permeance
more visit rockwool.com offering a high-density outer layer and a lower-density The water vapor permeance of ROCKWOOL
inner layer. The high-density outer layer offers greater insulation allows for increased potential for drying
rigidity and water repellency, while the inner layer helps without trapping transient moisture in the assembly.
to conform to architectural features. These products offer ROCKWOOL CAVITYROCK and COMFORTBATT are
® ®

R4.3/in thermal resistance values and allow the designer water repellent yet vapor permeable insulation products,
to reach higher exterior insulation thermal requirements and will allow transient vapors to pass through without
when necessary. restriction. Lower permeable insulations such as foam
plastics can work as vapor retarders and can greatly affect Soleno Project, Montreal, QC
the drying potential of many typical building assemblies. ROCKWOOL CAVITYROCK®

ROCKWOOL Group ROCKWOOL Group


7 8
Return to Commercial Applications
Meeting the Challenges of Today’s Climate Zones Build Your BEDR Wall Rainscreen System ™

COMFORTBATT ®

ASHRAE – History of R-Value Requirements


The American Society of Heating, Refrigerating and Air Canada Only US Only North America
Conditioning Engineers (ASHRAE) is an international
R-value and
Society of technical individuals who provide knowledge R14 (3.5”) R15 (3.5”) R22.5 (6”) R24 (6”)

Steel Stud – On Center


Thickness
to the building industry on heating, ventilation, air- v 16” 24” 16” 24” 16” 24” 16” 24”
conditioning, and refrigeration (HVAC&R). The Society 6 7 6
developed ASHRAE 90.1, an energy conservation 4 19.95 19.95 20.95 20.95 28.45 28.45 29.95 29.95 Stated R-value
R4.20 (1”)
standard that provides the minimum requirements for
12.15 13.45 12.35 13.75 13.85 15.55 14.45 16.25 7.36 Effective R-value

No Insulation in Steel Stud


Continuous Insulation (c.i.)
energy-efficient buildings. This standard, or an equivalent,
5 5
is applied today in many states for commercial, 22.05 22.05 23.05 23.05 30.55 30.55 32.05 32.05 Stated R-value
government and high-rise building applications. In R6.30 (1.5”)
4 14.25 15.55 14.45 15.85 15.65 17.25 15.75 17.55 8.96 Effective R-value
Canada, look to the National Building Code and refer to 3
section A-5.3.1.2 for information on condensation and 24.15 24.15 25.15 25.15 32.65 32.65 34.15 34.15 Stated R-value
2 3
energy conservation standards. R8.40 (2”)
2 16.35 17.65 16.55 17.95 18.05 19.75 18.65 20.45 11.56 Effective R-value
2
26.50 26.50 27.50 27.50 35.00 35.00 36.50 36.50 Stated R-value
R10.75 (2.5”)
1 18.70 20.00 18.90 20.30 20.40 22.10 21.00 22.80 13.91 Effective R-value

®
CAVITYROCK
ASHRAE 90.1 2013 All Buildings Non-Residential 28.65 28.65 29.65 29.65 37.15 37.15 38.65 38.65 Stated R-value
Specific to Cavity Wall/Rainscreen Requirements by ASHRAE Map of Climate Zones R12.90 (3”)
Climate Zone Every rating agency has its own maps that divide 20.85 22.15 21.05 22.45 22.55 24.25 23.15 24.95 16.06 Effective R-value

City/State Climate Zone Mass* Metal Framed**


regions into thermal or climate zones to tailor codes and 30.80 30.80 31.80 31.80 39.30 39.30 40.80 40.80 Stated R-value
standards to what is appropriate for that particular region. R15.05 (3.5”)
Miami, FL 1 NR R13 23.00 24.30 23.20 24.60 24.70 26.40 25.30 27.10 18.21 Effective R-value

Tampa, FL 2 R5.7 ci R13 + R3.8 ci


32.95 32.95 33.95 33.95 41.45 41.45 42.95 42.95 Stated R-value
Charleston, SC 3 R7.6 ci R13 + R5 ci R17.20 (4”)
25.15 26.45 25.35 26.75 26.85 28.55 27.45 29.25 20.36 Effective R-value
New York, NY 4 (except marine) R9.5 ci R13 + R7.5 ci
ASHRAE Correction Factors for Metal Wall Framing 37.25 37.25 38.25 38.25 45.75 45.75 47.25 47.25 Stated R-value
Spokane, WA 5 (and marine) R11.4 ci R13 + R10 ci R21.50 (5”)
Metal Stud Spacing Cavity Correction Effective 29.45 30.75 29.65 30.05 31.15 32.85 31.75 33.55 24.66 Effective R-value
Milwaukee, WI 6 R13.3 ci R13 + R12.5 ci Stud Size O.C. Insulation* Factor R-value
Anchorage, AK

Nome, AK
7

8
R15.2 ci

R19 ci
R13 + R12.5 ci

R13 + R18.8 ci
R11 0.50 5.50
15.75
No Insulation in the Exterior Cavity
15.75 16.76 16.75 24.25 24.25 25.75 25.75 Stated R-value

16” R13 0.46 6.00 7.95 9.25 8.15 9.55 9.65 11.35 10.25 12.05 Effective R-value

R15 0.43 6.40


* Wall without Steel Studs eg. Concrete 2x4
** Steel Stud and Cavity Wall R11 0.60 6.60

24” R13 0.55 7.20 ✔ Units in h.ft² °F/BTU Effective R-values - Example Calculation
R15 0.52 7.80 Components R-values
Canadian Equivalents to US Climate Zones ✔ Effective Insulation/Framing Layer R-values
R19 0.37 7.10
16”
between steel framing factors were obtained Exterior Cladding 0
City Province Climate Zone from ASHRAE 90.1-2013 Table A9.2-2
R21 0.35 7.40 Air Film Ext. 0.17
Vancouver British Columbia 5 2x6
R19 0.45 8.60 1.5” Air Space 0
Calgary Alberta 7 24”
✔ Effective R-values are shown for thermal
R21 0.43 9.00 design only. Assumes CAVITYROCK is installed ®
Insulation in the Cavity 6.3
Regina Saskatchewan 7
16” R25 0.31 7.80
as continuous insulation (c.i.). Exterior Gypsum Sheathing 0.45
Winnipeg Manitoba 7
2x8
Toronto Ontario 6 24” R25 0.38 9.60 ✔ Moisture and condensation potential should Stud Cavity Insulation 0.91

*Cavity Insulation = Steel Stud Wall Insulation be calculated for each assembly designed. Gypsum 0.45
Montreal Quebec 6

Halifax Nova Scotia 6 ✔ COMFORTBATT is also available in 2.5” for ®


Air Film Int. 0.68
steel stud applications. Total 8.96

For more detailed calculations, contact the ROCKWOOL Building Science team
to discuss your specific wall design and your required performance level at
1-800-265-6878.

ROCKWOOL Group ROCKWOOL Group


9 10
Return to Commercial Applications
Superior Sound Absorption ROCKWOOL Stone Wool: Fire Resistant,
Non-Combustible Insulation

Architects are increasingly choosing cladding façades ASTM E90 Sound Transmission Loss Test A key feature of ROCKWOOL products is their fire Fire Safety: Stone Wool Versus Foam
on buildings, which, when compared to brick, tends (Metal stud wall with exterior cladding system) resistance. CAVITYROCK is classified as “non- ®
More recently, as a result of the Shanghai fire in 2010,
to reduce the acoustical performance value of the combustible” as determined by ASTM E136 and new concerns have been raised about fire safety during
wall system. With recent trends towards the use of 60 CAN4-S114. It will not develop toxic smoke or promote construction. In the case of the Shanghai fire, foam
new lightweight construction techniques and cladding flame spread, even when directly exposed to fire, as some insulation was ignited accidentally during construction
50
materials, ROCKWOOL stone wool cavity wall insulation 60 other insulation materials do. When tested in accordance and quickly spread through the building exterior.
provides added acoustical value by outperforming 40
with ASTM E84, results typically show a flame spread of Because of these safety concerns, ROCKWOOL firmly
traditional foam plastic insulation. 50 0 and a smoke development of 0. By comparison, spray believes in the added value that passive fire resistance
30 polyurethane foam (SPUF) results, when tested to ASTM provides for buildings.
In a BEDR wall system, stone wool provides improved

40
E84, typically achieve a flame of 25 and smoke developed
low frequency sound absorption to both normal and 20
in the 350 to 500 range. ROCKWOOL CAVITYROCK and ®

30
random incidents of noise. Reduced noise in the COMFORTBATT stone wool insulation have a melting
®

workplace can result in a more efficient and pleasant work 10


20 point of approximately 2150ºF (1177ºC).
environment for building occupants. 0
10
The stone wool fiber orientation and increased density Assembly STC Assembly OITC

of both CAVITYROCK and COMFORTBATT , compared Temperature Development in a Standard Fire


® ®
0 ROCKWOOL CAVITYROCK® Extruded Polystyrene

to other types of insulation, effectively reduce sound (ASTM E119)


Polyisocyanurate With Thermal Cladding
Assembly STC Assembly OITC
transmission across the wall system. Greater noise ROCKWOOL CAVITYROCK® Extruded Polystyrene
or sound control is further achieved when thicker Polyisocyanurate With Thermal Cladding
CAVITYROCK , COMFORTBATT , and gypsum board are
® ® Test Wall: (Inside to Outside) 1/2” Gypsum, 6” Steel stud, ROCKWOOL 2400–
COMFORTBATT® insulation, 5/8” Gypsum board, Air/Vapor retarder, –1200
used together.
ROCKWOOL CAVITYROCK® insulation, 3/8” Cement board cladding. 2000– stone wool
melts –1000

Temperature (ºC)
Temperature (ºF)
1600–
–800
CAVITYROCK – ® 50
ASTM E90 Sound Transmission Loss Test 1200– fiberglass melts
–600
(Metal stud wall40without exterior cladding system)
Accoustical Performance 50 800– –400
30
40
ASTM C423 - Co-Efficients at Frequencies 400– polyurethane foam burns –200
20 polystyrene foam melts
30
0– –0
1000 2000 4000 0 2 4 6 8
The severity of the Shanghai fire was
Thickness 125 Hz 250 Hz 500 Hz NRC 10
Hz Hz Hz 20
Time (Hours) partially a result of the use of urethane
1.5” 0.19 0.55 1.03 1.06 1.02 1.01 0.90 0
10
Assembly STC Assembly OITC
foam insulation, which aided in the spread
2.0” 0.26 0.71 1.14 1.09 1.04 1.03 1.00
of flame and smoke.
0 ROCKWOOL CAVITYROCK® Extruded Polystyrene
3.0” 0.72 0.93 0.88 0.84 0.90 0.97 0.90
Polyisocyanurate
Assembly STC Assembly OITC
ROCKWOOL CAVITYROCK® Extruded Polystyrene
Polyisocyanurate

Fire Performance

Product Specification Test Result

CAVITYROCK® ASTM E136 Behavior of Materials at 1382ºF (750ºC) Non-Combustible

Test Wall: (Inside to Outside) ½” Gypsum, 6” Steel stud, Gypsum board, Air/Vapor Non-Combustibility in Building
CAVITYROCK®, COMFORTBATT® CAN4 S114 Non-Combustible
retarder, ROCKWOOL CAVITYROCK® insulation, Airspace, 3/8” Cement board Materials
cladding.
Flame Spread = 0
CAVITYROCK® ASTM E84 (UL 723) Surface Burning Characteristics
Smoke Developed = 0

Flame Spread = 0
CAVITYROCK®, COMFORTBATT® CAN/ULC S102 Surface Burning Characteristics
Smoke Developed = 0

ROCKWOOL Group ROCKWOOL Group


11 12
Return to Commercial Applications
6 7 6
4

Moisture Management Long-Term Performance


New York
New York
5 5

Moisture Retention Comparison Double Vapor Barriers can Lead to Moisture Problems 4 WUFI* – Moisture Content within BEDR Wall over 3 WUFI* – Moisture Content within BEDR Wall over 3
To obtain a better understanding of the characteristics of 3 transport and air
Building enclosures see vapor Years in Climate Zone 1 Years in Climate Zone 4
in situ thermal insulation within cavity walls, a Certified movement through the assembly. Although both should
Building Science Expert at ROCKWOOL reviewed two 2 3 6 7 6
be mitigated when designing, air transport will carry
applicable scenarios in Seattle, Washington. The scenarios higher moisture levels, which could lead to significant 4 2
were modeled for a three-year period and the theoretical moisture problems. 2 Florida
wall was located at mid-level of a high-rise on the western New York
elevation. The charts below represent the first modeled Vapor barriers (retarders) are typically required on Miami New York

scenario. Note that, in this scenario, CAVITYROCK had ®


the warm side of the assembly (i.e. the interior side 5 1 5
much less moisture content over the same period than for colder climates). As such, the permeability of the
XPS foam insulation under the same conditions. insulating materials and the exterior weather resistive 4
barrier/air barrier is critical to avoid the use of double
3
vapor barriers and ensure the wall assembly is able to
dry out appropriately.
2 3
Wall with ROCKWOOL CAVITYROCK ®

[(Water Content (kg/m3)] 2


2 Florida
Layer/Material
Start of End of
Min. Max. Vapor Permeability
Calc. Calc. Miami
CAVITYROCK and COMFORTBATT are water repellent,
® ®

Brick (Old) 3.34 2.91 1.19 195.38 yet vapor permeable insulation (30-40 perms) and will 1
Air Layer 25 mm 1.88 2.07 0.46 23.48
allow transient vapors to pass through without restriction.
This vapor permeable quality of ROCKWOOL’s cavity wall
ROCKWOOL CAVITYROCK ®
0.02 0.02 0.00 0.07
insulation allows for an increased potential for drying
Vapor Retarder (1 perm) 0.00 0.00 0.00 0.00 without trapping water in the wall assembly.
Concrete Blocks, Graphs indicate the moisture performance of CAVITYROCK® over a 3-year timeframe.
28.00 11.13 8.33 28.00 Lower-permeability insulations such as spray foam or
Pumice Aggregate
XPS can function as vapor retarders and may affect CAVITYROCK® dries out year over year to the same levels, indicating that moisture does not build up in the insulation over time.
Total Water Content drying potential of typical building assemblies if not
6.0 2.58 2.16 24.79
(kg/m2)
designed appropriately.
Results: Mineral wool insulation in a typical cavity wall will at maximum increase
water content from 0.02 kg/m3 to 0.07 kg/m3. XPS had an increase The stone wool insulation in a cavity wall assembly does
BEDR Wall Layer/Material Start of End of BEDR Wall Layer/Material
in water content from 0.31 kg/m3 to 0.68 kg/m3. not wick water, which means that any bulk water that Min. Max. Start of End of
CLIMATE ZONE 1 Calc. Calc. Min. Max.
Calc. Calc.
contacts the outer surface will drain and not be absorbed CLIMATE ZONE 4
Ten air changes/hour were included in this calculation. Cement Board 43.71 197.46 16.46 349.35
into the body of the insulation.
Cement Board 43.71 144.77 13.08 348.58
Air Layer (25 mm) 1.88 13.97 0.45 26.14
Air Layer (25 mm) 1.88 9.46 0.34 17.99
ROCKWOOL CAVITYROCK® 0.20 2.19 0.05 3.89
WUFI* – Seattle, Washington Climate Zone 4 Wall ROCKWOOL CAVITYROCK® 0.20 0.46 0.04 1.60
with XPS [(Water Content (kg/m3)] Vapor Retarder (10 perm) 0.00 0.00 0.00 0.00
Vapor Retarder (10 perm) 0.00 0.00 0.00 0.01
Start of End of Gypsum Board (USA) 6.19 4.32 2.74 6.19
Layer/Material Min. Max. Gypsum Board (USA) 6.19 6.18 2.44 11.79
Calc. Calc.
ROCKWOOL COMFORTBATT® 0.07 0.04 0.02 0.07
Brick (Old) 3.34 3.01 1.19 195.38 ROCKWOOL COMFORTBATT® 0.07 0.06 0.01 1.41
Interior Gypsum Board 8.65 5.24 3.45 8.65
Air Layer 25 mm 1.88 2.44 .044 24.27 Vapor Retarder (0.1 perm) 0.00 0.00 0.00 0.00
Total Water Content* 0.79 3.05 0.3 5.19
Extruded Polystyrene 0.31 .033 0.12 0.68 Interior Gypsum Board 8.65 4.99 3.56 8.65
*Water content (kg/m3)
Vapor Retarder (1 perm) 0.00 0.00 0.00 0.00 Total Water Content* 0.79 2.21 0.28 4.86

Concrete Blocks,
28.00 10.85 8.17 28.00 *Water content (kg/m3)
Pumice Aggregate
ROCKWOOL CAVITYROCK® thermal insulation has a very low moisture vapor
Total Water Content sorption and does not permit the horizontal transmission of bulk moisture through
6.03 2.58 2.13 24.89 the material or the assembly.
(kg/m2)

*WUFI is the acronym for “Wärme – und Feuchtetransport instationär” (“Transient


Heat and Moisture Transport”). WUFI is designed to calculate the simultaneous
heat and moisture transport in multi-layered building components.

ROCKWOOL Group ROCKWOOL Group


13 14
Return to Commercial Applications
At the ROCKWOOL Group, we are
committed to enriching the lives of
everyone who comes into contact
with our solutions. Our expertise
is perfectly suited to tackle many of
today’s biggest sustainability and
development challenges, from energy
consumption and noise pollution
to fire resilience, water scarcity and
flooding. Our range of products
reflects the diversity of the world’s
needs, while supporting our
stakeholders in reducing their own
carbon footprint.

Stone wool is a versatile material and


forms the basis of all our businesses.
With more than 11,000 employees
in 39 countries, we are the world
leader in stone wool solutions,
from building insulation to acoustic
ceilings, external cladding systems
to horticultural solutions, engineered
fibres for industrial use to insulation
for the process industry and marine
and offshore.

AFB , CAVITYROCK ,
® ®

COMFORTBATT , CONROCK ,® ®

CURTAINROCK , ROCKBOARD ,
® ®

TOPROCK , MONOBOARD , ROXUL


® ® ®

are registered trademarks of the


ROCKWOOL Group in USA and
ROXUL Inc. in Canada.

ROCKWOOL , COMFORTBOARD ,
™ ™

FABROCK , ROXUL SAFE ,


™ ™

ROCKWOOL PLUS , and AFB evo™ ™

are trademarks of the ROCKWOOL


Group in USA and ROXUL Inc. in
Canada.

SAFE’n’SOUND is a registered
®

Publication date - edition: 01/2018


trademark used under license by
Masonite Inc.

ROCKWOOL
8024 Esquesing Line
Milton, ON L9T 6W3
Tel: 1 800 265 6878
rockwool.com
Return to Commercial Applications
CAVITYROCK CAVITYROCK
® Technical Data Sheet
®
Board Insulation 07210* • Board Insulation 07 21 13**
Cavity Wall Unit Masonry 04 27 23**
Exterior Insulation for Cavity Wall
Exterior Insulation for Cavity Wall and Rainscreen Applications
and Rainscreen Applications
ROCKWOOL CAVITYROCK® is a semi-rigid, mineral wool insulation board designed for exterior cavity wall
and rainscreen applications.

Performance Test Standard

Mineral Fiber Block and Board Thermal Insulation - Type IVB Compliant ASTM C612

Compliance MEA Approval, New York City Approval 236 - 05 - M

For information on CAN/ULC S702 compliance, contact ROCKWOOL Technical Support

Flame spread index = 0; Smoke developed index = 0 ASTM E84 (UL 723)

Flame spread index = 0; Smoke developed index = 0 CAN/ULC S102


Reaction to Fire
Determination of Non Combustibility of Building Materials - Non Combustible CAN/ULC S114

Behaviour of materials at 750°C - Non Combustible ASTM E136

Density (thickness:1”, 1.5”) Monolithic Density of 5.3 lbs/ft³ (85 kg/m³) ASTM C303
Density (thickness: 2”) Monolithic Density of 4.4 lbs/ft³ (70 kg/m³)

Density (thickness ≥ 2.5”) Dual Density - 6.2 lbs/ft³ (100 kg/m³) outer layer and 4.1 lbs/ft³ (65 kg/m³) inner layer ASTM C303

Stress Corrosion Cracking Tendency of Austenitic Stainless Steel - Passed ASTM C795
Corrosion Resistance
Corrosion of Steel - Passed ASTM C665

R-Value / inch @ 75 F
o
4.3 hr.ft2.F/Btu
Thermal Resistance RSI value / 25.4 mm @ 24 C
o
0.75 m2K/W ASTM C518 (C177)

Moisture Sorption - 0.03% by volume ASTM C1104

Reaction to Moisture Water Vapor Transmission, Desiccant Method - 1555ng/Pa.s.m (27 perm) 2
ASTM E96
Thermal Performance
Determination of Fungi Resistance - Passed ASTM C1338
The use of CAVITYROCK® as a
ROCKWOOL CAVITYROCK® products are semi-rigid continuous insulation helps you Thickness 1” (25.4 mm) to 4” (101.6 mm) in 1/2” increments. 5” (127 mm) and 6” (152.4 mm)
stone wool insulation boards designed for exterior cavity Dimensions 24” x 48” (610 mm x 1219 mm) and 16” x 48” (406 mm x 1219 mm)
meet building code requirements.
wall and rainscreen applications, and are compatible
Thickness 125 Hz 250 Hz 500 Hz 1000 Hz 2000Hz 4000 Hz NRC ASTM C423
with numerous cladding attachment systems.
1.5” 0.19 0.55 1.03 1.06 1.02 1.01 0.9
CAVITYROCK® is non-combustible and fire resistant, Acoustical Performance
2” 0.26 0.71 1.14 1.09 1.04 1.03 1
and will not develop toxic smoke or promote
flame spread, even when directly exposed to fire. 3” 0.72 0.93 0.88 0.84 0.9 0.97 0.9
Approved for use in many NFPA 285-compliant designs,
it is an important component of fire-resilient exterior
wall systems when used as a continuous insulation.

CAVITYROCK® also offers long-term thermal efficiency,


moisture control and acoustic performance – improving Issued 01-01-18 NOTE: *Master Format 1995 Edition **Master Format 2004 Edition. As ROCKWOOL has no control over installation design and
Supersedes 08-23-17 workmanship, accessory materials or application conditions, ROCKWOOL does not warranty the performance or results of any
the energy efficiency and comfort of buildings. installation containing ROCKWOOL’s products. ROCKWOOL’s overall liability and the remedies available are limited by the general
terms and conditions of sale. This warranty is in lieu of all other warranties and conditions expressed or implied, including the warranties
Choose mono-density insulation in thicknesses up of merchantability and fitness for a particular purpose.

to 2” or dual-density in thicknesses of 2.5” to 6”.

Learn more at rockwool.com

8024 Esquesing Line, Milton, ON L9T 6W3


Tel: 800-265-6878 • Fax: 800-991-0110
rockwool.com
ROCKWOOL Group ROCKWOOL Group
16 17
Return to Commercial Applications
COMFORTBATT
COMFORTBATT
®
Technical Data Sheet
® Batt Insulation 07210*
Thermal Batt Insulation Blanket Insulation 07 21 16**

Thermal Batt Insulation


ROCKWOOL COMFORTBATT® is a mineral wool batt insulation designed for thermal resistance in wood and steel framing.

Performance Test Standard

Compliance Mineral Fibre Thermal Insulation for Buildings, Type 1 Compliant CAN/ULC S702

Flame spread index = 0; Smoke developed index = 0 CAN/ULC S102


Reaction to Fire
Determination of Non-combustibility of Building Materials - Non-combustible CAN/ULC S114

Density > 2 lbs/ft³ (>32 kg/m³) ASTM C167

Wood Stud Steel Stud ASTM C518

R14 (RSI 2.47) - 3.5" thick (89 mm) R10 (RSI 1.76) - 2.5" thick (64 mm)

R22 (RSI 3.87) - 5.5" thick (140 mm) R14 (RSI 2.47) - 3.5" thick (89 mm)
Thermal Resistance
R24 (RSI 4.23) - 5.5" thick (140 mm) R22.5 (RSI 3.96) - 6" thick (152 mm)

R28 (RSI 4.93) - 7.25" thick (184 mm) R24 (RSI 4.23) - 6" thick (152 mm)

R32 (RSI 5.64) - 8" thick (203 mm)

Wood Stud 16” (406 mm) on centre: 15.25” x 47” (387 mm x1194 mm)

Wood Stud 24” (610 mm) on centre: 23” x 47” (584 mm x 1194 mm)
Dimensions
Steel Stud 16” (406 mm) on centre: 16.25” x 48” (413 mm x 1219 mm)

Steel Stud 24” (610 mm) on centre: 24.25” x 48” (616 mm x 1219 mm)

Easy Fit
Easily cut to achieve an optimal fit around pipes,
ROCKWOOL COMFORTBATT® is a semi-rigid stone electrical wiring boxes, ductwork and between Issued 01-01-18 NOTE: *Master Format 1995 Edition **Master Format 2004 Edition. As ROCKWOOL has no control over installation design and
wool batt insulation for exterior wood and steel stud studs and joists that are less than standard width. Supersedes 08-23-17 workmanship, accessory materials or application conditions, ROCKWOOL does not warranty the performance or results of any
installation containing ROCKWOOL’s products. ROCKWOOL’s overall liability and the remedies available are limited by the general
applications in both new construction and renovations. terms and conditions of sale. This warranty is in lieu of all other warranties and conditions expressed or implied, including the warranties
of merchantability and fitness for a particular purpose.
It features a unique flexible edge designed to compress
as the batt is inserted then spring back, expanding the
batt against the frame studs to give a complete fill. This
flexibility ensures the expected R-value is achieved and
maintained.

Non-combustible and fire resistant, COMFORTBATT® will


not develop toxic smoke or promote flame spread, even
when exposed directly to a fire. It also offers water and
moisture resistance and excellent sound absorbency.

COMFORTBATT® is an effective way to improve a home’s


energy efficiency. It is GREENGUARD Gold Certified and
contributes to a healthier indoor environment.

Learn more at rockwool.com

8024 Esquesing Line, Milton, ON L9T 6W3


Tel: 800-265-6878 • Fax: 800-991-0110
rockwool.com
Return to Commercial Applications
CONTINUOUS INSULATION

COMFORTBOARD 110

High-Performance Thermal Insulated Sheathing

Return to Commercial Applications


Moisture Resistance ROCKWOOL COMFORTBOARD 110 Creates Breathable ™

Standard Wall Systems


ASTM C1104 Moisture Sorption 0.28 %

Water Vapor
ASTM E96 Transmission, Desiccant
2160 ng/Pa.s.m2 ROCKWOOL COMFORTBOARD 110 (Thermal Insulated ™

Method
(35 perm) Sheathing) is a rigid, high-density, stone wool insulation
board designed for use as an exterior continuous ✔ Vapor Permeable
ASTM C209 Water Absorption 1.2 %
insulation in commercial applications. Fire Resistant

COMFORTBOARD 110 is a thermally efficient,



✔ Environmentally
Fire Resistant moisture resistant, vapor permeable board and takes Sustainable
COMFORTBOARD 110 is fire resistant, able to withstand

the place of other external sheathing insulations to create
temperatures up to 2150°F (1177°C), and does not high-performance wall assemblies that are effective ✔ Moisture Resistant
produce smoke or propagate flames. This provides a against fire, moisture and thermal bridging, and allow for
critical line of defense, keeping occupants safe and ✔ Stable Long-Term
superior drying potential.
reducing property damage in the event of a fire. R-Value
This high-density board provides the rigidity and
✔ Dimensionally
durability needed for many exterior cladding assemblies,
Stable
such as lightweight metal and composite panels
Fire Performance systems. COMFORTBOARD 110 is available in standard

✔ UV Resistant
thicknesses of 1”, 1.25”, 2”, 2.5” and 3” with R-values
Standard
ranging from R4 to R12. ✔ Sound Absorbent
Test for
CAN4 S114 Non-Combustible
Non-Combustibility
A True Continuous Insulation
Surface Burning Flame Spread = 0 The ROCKWOOL BEDR Wall Rainscreen System is ideal for metal panel systems

ASTM E84 (UL 723)


Characteristics Smoke Developed = 0 In commercial steel stud applications, thermal bridging and comprises a high-density, rigid COMFORTBOARD 110 board in the external

plays a large part in heat loss, leading to increased cavity, combined with ROCKWOOL thermal COMFORTBATT insulation in the ®

Surface Burning Flame Spread = 0


CAN/ULC S102 energy consumption. This assembly provides a exterior stud wall cavity.
Characteristics Smoke Developed = 0
true continuous insulation, when combined with
ROCKWOOL COMFORTBATT Steel Stud insulation in
®

the stud wall to form a high-performance, split insulation


wall system. COMFORTBOARD 110 has superior ™ Thermal Resistance
Dimensionally Stable compressive resistance and is compatible with lightweight Standard Temperature R-value/inch RSI value/25.4
Metal panel cladding assemblies are subject to wide hat channel supported cladding systems, eliminating
temperature changes from the exterior. This can cause the need for Z-furring strips which can cause thermal ASTM C518 (C177) 25˚F (-4˚C) 4.3 hr.ft2.F/Btu 0.74 m2K/W
shrinking and expanding in other insulation materials, bridging. This allows for a reduced overall thickness of the 40˚F (4˚C) 4.2 hr.ft2.F/Btu 0.72 m2K/W
resulting in gaps and significant heat loss in cold wall system and greatly improves the energy efficiency of
Energy Efficient/Vapor Permeable
temperatures and vice versa in warm temperatures. the building. 75˚F (24˚C) 4.0 hr.ft2.F/Btu 0.70 m2K/W
The trend toward energy efficiency is driving the need for
COMFORTBOARD 110 remains dimensionally

high-performance building envelopes. These advanced 110˚F (43˚C) 3.6 hr.ft2.F/Btu 0.64 m2K/W
stable behind the assembly wall and does not expand, COMFORTBOARD 110 provides maximum thermal

wall systems are designed to produce higher effective


contract or bow with thermal cycles. This provides for performance, fire resistance and drying potential using
R-values and minimize air leakage. This increases the
a long-term, energy-efficient wall assembly. sustainable materials.
need to design walls more carefully and reduce the risk of
trapping moisture. Compressive Strength
COMFORTBOARD 110 vapor permeable exterior

Standard
insulation enables high-performance wall systems to
ASTM C165 at 10% 1220 psf (58.5 kPa)
have superior drying potential, minimizing the risk
of condensation and water accumulation. The vapor at 25% 1880 psf (90.0 kPa)
permeance of ROCKWOOL insulation allows for
increased drying potential without trapping transient
moisture in the assembly. Foam plastic insulations have
low vapor permeability and can work as vapor retarders. Product Details
This may trap moisture within the wall, leading to mold or
premature deterioration of building components. Product Density Standard Thickness R-value Standard Dimensions W x L

ASTM C165-00 24” x 48” (610 mm x 1219 mm)


COMFORTBOARD™ 110 1”, 1.25”, 2.0”, 2.5”, 3” R4, R5, R8, R10, R12
Actual 11 lb/ft3 , (176 kg/m3) 48” x 72” (1219 mm x 1829 mm)

ROCKWOOL Group ROCKWOOL Group


2 3
Return to Commercial Applications
At the ROCKWOOL Group, we are
committed to enriching the lives of
everyone who comes into contact
with our solutions. Our expertise
is perfectly suited to tackle many of
today’s biggest sustainability and
development challenges, from energy
consumption and noise pollution
to fire resilience, water scarcity and
flooding. Our range of products
reflects the diversity of the world’s
needs, while supporting our
stakeholders in reducing their own
carbon footprint.

Stone wool is a versatile material and


forms the basis of all our businesses.
With more than 11,000 employees
in 39 countries, we are the world
leader in stone wool solutions,
from building insulation to acoustic
ceilings, external cladding systems
to horticultural solutions, engineered
fibres for industrial use to insulation
for the process industry and marine
and offshore.

AFB , CAVITYROCK ,
® ®

COMFORTBATT , CONROCK ,® ®

CURTAINROCK , ROCKBOARD ,
® ®

TOPROCK , MONOBOARD , ROXUL


® ® ®

are registered trademarks of the


ROCKWOOL Group in USA and
ROXUL Inc. in Canada.

ROCKWOOL , COMFORTBOARD ,
™ ™

FABROCK , ROXUL SAFE ,


™ ™

ROCKWOOL PLUS , and AFB evo™ ™

are trademarks of the ROCKWOOL


Group in USA and ROXUL Inc. in
Canada.

SAFE’n’SOUND is a registered
®

Publication date - edition: 01/2018


trademark used under license by
Masonite Inc.

ROCKWOOL
8024 Esquesing Line
Milton, ON L9T 6W3
Tel: 1 800 265 6878
rockwool.com
Return to Commercial Applications
COMFORTBOARD 110 COMFORTBOARD™ 110
Technical Data Sheet
™ Board Insulation 05080*
Board Insulation 07 21 13**
Continuous Insulation
Continuous Insulation
ROCKWOOL COMFORTBOARD™ 110 is a rigid mineral wool, non-structural insulated sheathing board used
as continuous insulation in high-performance wall systems.

Performance Test Standard

Mineral Fiber Block and Board Thermal Insulation - Type IVB Compliant ASTM C612
Compliance
Mineral Fibre Thermal Insulation for Buildings - Type 1 Compliant CAN/ULC S702

Flame spread index = 0; Smoke developed index = 0 ASTM E84 (UL 723)
Reaction to Fire Flame spread index = 0; Smoke developed index = 0 CAN/ULC S102
Determination of Non Combustibility of Building Materials - Non Combustible CAN/ULC S114

Density Actual Density - 11 lbs/ft³ (176 kg/m³) ASTM C303

Stress Corrosion Cracking Tendency of Austenitic Stainless Steel - Passed ASTM C795
Corrosion Resistance Corrosion of Steel - Passed ASTM C665
Corrosion to Aluminum - Passed ASTM C665

R-Value / inch @ 75oF 4 hr.ft2.F/Btu


Thermal Resistance RSI value / 25.4 mm @ 24oC 0.70 m2K/W ASTM C518 (C177)

Moisture Sorption - 0.28% ASTM C1104


Water Vapor Transmission, Desiccant Method - 2160ng/Pa.s.m2 (35 perm) ASTM E96
Reaction to Moisture
Water Absorption - 1.2% ASTM C209
Determination of Fungi Resistance - Passed ASTM C1338

584psf (28kPa) @ 10% compression ASTM C165


Compressive Strength
1566psf (75kPa) @ 25% compression

Thickness 1” (25.4 mm), 1.25” (32 mm), 2” (50.8 mm), 2.5” (63.5 mm), 3” (76.2 mm)
Dimensions 24” x 48” (610 mm x 1219 mm), 48” x 72” (1219 mm x 1829 mm)

Thickness 125 Hz 250 Hz 500 Hz 1000 Hz 2000Hz 4000 Hz NRC ASTM C423

Acoustical Performance 1” 0.13 0.49 0.85 0.89 0.89 0.97 0.8


Thermal Performance
2” 0.5 0.71 0.85 0.9 0.96 1.01 0.85
Compatible with screw through supported
ROCKWOOL COMFORTBOARD™ 110 is a rigid, cladding systems, COMFORTBOARD™ 110 Issued 01-01-18 NOTE: *Master Format 1995 Edition **Master Format 2004 Edition. As ROCKWOOL has no control over installation design and
Supersedes 08-23-17 workmanship, accessory materials or application conditions, ROCKWOOL does not warranty the performance or results of any
high-density, non-combustible stone wool insulation reduces thermal bridging. installation containing ROCKWOOL’s products. ROCKWOOL’s overall liability and the remedies available are limited by the general
board designed for use as an exterior continuous terms and conditions of sale. This warranty is in lieu of all other warranties and conditions expressed or implied, including the warranties
of merchantability and fitness for a particular purpose.
insulation in commercial applications.

Thermally efficient, moisture resistant and vapor


permeable, COMFORTBOARD™ 110 is a non-structural
external sheathing insulation that creates high-performance
wall assemblies to improve the energy efficiency and fire
resilience of buildings.

The vapor permeance of ROCKWOOL insulation allows


for increased drying potential without trapping transient
moisture in the assembly, reducing the risk of mold or
corrosion of building components.

COMFORTBOARD™ 110 provides the rigidity and


durability needed for many exterior cladding assemblies,
such as metal and composite panel systems.

Learn more at rockwool.com

8024 Esquesing Line, Milton, ON L9T 6W3


Tel: 800-265-6878 • Fax: 800-991-0110
rockwool.com
ROCKWOOL Group ROCKWOOL Group
5 6
Return to Commercial Applications
ACOUSTICAL FIRE BATT INSULATION

ROCKWOOL AFB
®

Acoustical Fire Batt Insulation for Commercial


& Interior Partition Wall.

Return to Commercial Applications


Batt insulation that fights
both fire and noise.
Density and Airflow Resistivity for Samples of Absorptive Material
ROCKWOOL AFB ®

Density (kg/m3) Airflow Resistivity (mks rayls/m)


ROCKWOOL AFB is a lightweight, batt insulation
®

specifically designed for steel stud interior wall Average Value Standard Deviation Average Value Standard Deviation
AFB – Acoustically Better
®

and floor applications. Glass Fiber 3½” (89 mm) batt 12.2 0.4 4,800 400
Sound Transmission Class (STC) values don’t take
Glass Fiber 2½” (65 mm) batt 11.7 1.0 3,600 200
This stone wool insulation is made from natural stone and into account Lower Frequency Sounds (LFS) which
recycled content. It’s a sustainable product that provides can cause vibrations between rooms, negatively ROCKWOOL AFB® 3” (75 mm) batt 44.2 1.7 16,600 900

superior sound absorbency and fire protection for overall affecting the sound environment. The higher
occupant comfort and safety. That’s why AFB is quickly density of ROCKWOOL AFB® can reduce sound
®

becoming the insulation of choice for today’s green transmission, helping to create a quiet
builders in commercial and industrial construction. and comfortable space.
Random Incidence Sound Absorption Coefficients, in 1/3 Octave Band

1/3 Octave Band Center Frequency (Hz)

65 80 100 125 160 200 250

Glass Fiber Sample 1 3½” 0.15 0.18 0.21 0.25 0.32 0.43 0.54

Sound Control Glass Fiber Sample 2 3½” 0.15 0.17 0.19 0.22 028 0.37 0.48
When ROCKWOOL AFB is specified for interior wall or
®
ROCKWOOL AFB® Sample 1 3” 0.18 0.22 0.28 0.33 0.40 0.50 0.62
floor assemblies, better overall sound control and fire ROCKWOOL AFB® Sample 2 3” 0.18 0.23 0.29 0.24 0.41 0.52 0.65
protection are achieved. Compared to other types of
Glass Fiber Sample Average 3” 0.15 0.18 0.20 0.20 0.30 0.40 0.50
insulation, AFB provides increased density that effectively
®

reduces airflow and essentially, sound transmissions. ROCKWOOL AFB® Sample


3” 0.18 0.23 0.29 0.34 0.41 0.51 0.64
Average
Greater noise or sound control is further achieved when
thicker AFB and gypsum board are used together. AFB
® ®

thickness ranges from 1.0”


(25 mm) to 6” (152 mm). Acoustical Performance
In commercial applications, much of the sound to be
controlled is in the low frequency or bass ranges. This ASTM E 90 Airborne Sound Transmission Loss Tested
noise includes conversation, projection/video equipment, ASTM E 413 Rating Sound Insulation Tested
mechanical rooms and ventilation systems. In the lower
ASTM C 423 Sound Absorption Coefficients Tested
1/3 octave bands, ROCKWOOL AFB outperforms glass
®

wool insulation, providing more low frequency absorption ASTM E 1050 Impedance and Absorption of Acoustical Materials Tested

when comparing acoustical testing at low frequencies (see


chart “Random Incidence Sound Absorption Coefficients,
in 1/3 Octave Band”, pg. 3).
ASTM C423

Coefficients at Frequencies

Thickness 125 Hz 250 Hz 500 Hz 1000 Hz 2000 Hz 4000 Hz NRC

1.0” 0.14 0.25 0.65 0.90 1.01 1.01 0.70

1.5” 0.18 0.44 0.94 1.04 1.02 1.03 0.85

2.0” 0.28 0.60 1.09 1.09 1.05 1.07 0.95

3.0” 0.52 0.96 1.18 1.07 1.05 1.05 1.05

4.0” 0.86 1.11 1.20 1.07 1.08 1.07 1.10

ROCKWOOL Group ROCKWOOL Group


2 3
Return to Commercial Applications
Features and benefits that set AFB apart.
®

Fire Resistant Water Repellent Sag-Free, Tight Fit Fast, Easy Installation
ROCKWOOL AFB is non-combustible and will not
®
ROCKWOOL AFB will not absorb or hold water and will
®
The higher density of AFB provides superior sag
®
Working with ROCKWOOL insulation is a breeze. Simply
develop toxic smoke or promote flame spread, even not promote mold or fungi growth. It has superior drying resistance and fit. AFB holds its shape without sagging
®
cut with a serrated knife for quick and efficient installation
when directly exposed to fire. AFB will therefore not
®
potential, effectively managing moisture in the event that or slumping in the wall cavity over time to consistently between studs, around electrical boxes, pipes, wiring,
add fuel to an existing fire, making it ideal for use in high it does get into the wall or floor, allowing it to dry out and provide continuous fire protection and sound control. ductwork and between studs and joists that are less than
occupancy buildings. Studies have shown that mineral maintain its sound and fire properties. a standard width.
wool insulated rooms provide a 54% increase in overall
fire resistance rating compared to non-insulated rooms.
Since stone wool does not contribute to a fire, it can
provide valuable extra time for people to reach safety, a
critical factor especially in health and education facilities.
It can also provide fire services personnel additional time
to control the spread of fire while reducing property
damage.

Fire Performance Corrosive Resistance


CAN4 S114 Test for Non-Combustibility Non-Combustible ASTM C 665 Corrosiveness to Steel Pass

ASTM E 136 Behavior of Materials at 750 °C (1382 °F) Non-Combustible Stainless Steel Stress Corrosion Specification as per Test Methods C871 and
ASTM C 795 **** C692: U.S. Nuclear Regulatory Commission, Reg. Guide #1.36: U.S. Military Conforms
Flame Spread = 0
CAN/ULC S102 Surface Burning Characteristics Specifications MIL-I-24244 (all versions including B and C)
Smoke Developed = 0

Flame Spread = 0
ASTM E84 (UL 723) Surface Burning Characteristics
Smoke Developed = 0

CAN/ULC S129 Smolder Resistance 0.09%


Air Erosion
UL 181 Maximum Air Velocity 1000 fpm (5.08 m/s)

ROCKWOOL Group ROCKWOOL Group


4 5
Return to Commercial Applications
Compliance and performance. Commercial wall system performance
using ROCKWOOL AFB . ®

CAN/ULC-S702-07 Mineral Fiber Thermal Insulation for Buildings Type 1, Complies

ASTM C 665 Mineral Fiber Blanket Thermal Insulation Type 1, Complies

ASTM C 553 Mineral Fiber Blanket Thermal Insulation Complies In the following 13 commercial wall For other wall constructions
MEA Approval New York City Approval 338-97-M systems, ROCKWOOL AFB delivers
®
not shown here, please contact
City Of Los Angeles approval RR 25444 excellent fire resistance ratings and ROCKWOOL technical services.
ULC Design Nos. U311, W406, W408, W419, W423, W440, W441, W442, W508, W600, Z500
Sound Transmission Class (STC).
For further details on the illustrated
UL Design Nos. U305, U311, U317, U411, U412, U448, U465, V417, V418, V419 The right-hand column shows the constructions, consult the UL or ULC
results of acoustical tests done on Design Manual. All STC Ratings are
these ROCKWOOL AFB wall systems
®
based on Type X gypsum board.
at the internationally-recognized
Riverbank Acoustical Laboratories.

Dimensions
16.25” (width) x 48” (length)

412.75 mm (width) x 1219 mm (length)

24.25” (width) x 48” (length)


Construction Description Transmission Loss
615.95 mm (width) x 1219 mm (length)
1 Single layer wall Transmission loss (dB)
5/8” (15.9 mm) gypsum board 70
60
Thickness 3 5/8” (92 mm) steel studs spaced 50
24” (610 mm) centers
Product thickness is available in 1” to 3.5” 40
with ½” increments as well as 4”, 5” and 6” offerings. 3” (76 mm) ROCKWOOL AFB ®
30
20
Sound Transmission Class 10
52 (RAL-TL95-195)
Density 0

2” thickness 2.8 lbs/ft3 45 kg/m3


Fire Resistance 160 250 400 630 1000 1600 2500 4000
Frequency (Hz)
1 hour (UL design no. V417 and U465)
1 hour (ULC W447)
Transmission loss (dB)
70
60
50
40
30
20
10
0
160 250 400 630 1000 1600 2500 4000
Frequency (Hz)

Transmission loss (dB)


What is STC? 70
The Sound Transmission Class (STC) is a single-number rating of an assembly’s
60 ability to resist airborne sound
transfer at the frequencies 125-4000 Hz. In general, a higher STC rating blocks
50 more noise from transmitting
through a partition.
40
30
20
ROCKWOOL Group ROCKWOOL Group
6 7
Return to Commercial Applications
10
0
60 60 60 60
10 10 10 10
50 50 50 50
0 0 0 0
40 160 250 400 630 1000 1600 2500 4000 40 160 250 400 630 1000 1600 2500 4000 40 160 250 400 630 1000 1600 2500 4000 40 160 250 400 630 1000 1600 2500 4000
Transmission loss (dB) Transmission loss (dB) Transmission loss (dB) Transmission loss (dB)
Construction Description Transmission
30 Loss Frequency (Hz) 30 Construction Frequency (Hz) 30 Description Frequency (Hz) Transmission
30 Loss Frequency (Hz)
70 70 70 70
20 20 20 20

2 Single layer wall


60
Transmission loss (dB)
10
50
60
5
Transmission loss (dB)
10
50
60
Single
Transmission
Transmission
10 layer
loss (dB) wall
loss (dB)
50 1/2” (12.7 mm) gypsum board
60
Transmission loss (dB)
Transmission
10
50
loss (dB)
1/2” (12.7 mm) gypsum board 70 70 70 70 70 70
0 0 0 0
40 160 250 400 630 1000 1600 2500 4000
60 40 160 250 400 630 1000 1600 2500 4000
60 60 40 160 250 400 630 1000 1600 2500 4000
60 60 40 160 250 400 630 1000 1600 2500 4000
60
3 5/8” (92 mm) steel studs spaced 30
50 Frequency (Hz) 30
50 Frequency (Hz) 50 30 2 1/2” (64 mm) steel studs
50
spaced
Frequency (Hz) 50 30
50 Frequency (Hz)
24” (610 mm) centers 20 20 40 20 24” (610 mm) centers 40 20
40 40 40 40
Transmission
10 loss (dB) Transmission
10 loss (dB) 30 Transmission
Transmission loss (dB)
loss (dB)
10 2 1/2” Transmission
Transmission
30 10 loss (dB)
loss (dB)
3” (76 mm) ROCKWOOL AFB ®
30 30 30 (64 mm) ROCKWOOL AFB® 30
70 70 70
20 70 70
20 70
0
20 0
20 0
20 0
20
Sound Transmission Class 60 160 250 400 630 1000 1600 2500 4000 60 160 250 400 630 1000 1600 2500 4000 60
10 60 Sound
160 250 Transmission
400 630 1000Class
1600 2500 4000 60
10 60 160 250 400 630 1000 1600 2500 4000
10 10 10 10
51 (RAL-TL96-269) 50 Frequency (Hz) 50 Frequency (Hz) 50
0 50 44 (RAL-TL96-285) Frequency (Hz) 50
0 50 Frequency (Hz)
0 0 0 0
40 160 40 160
40 160 250 400 630 1000 1600 2500 4000 40 160 250 400 630 1000 1600 2500 4000 40 250160 250 400 630 1000 16004000
400 630 1000 1600 2500 160 250 400 630 1000 16004000
40 250 400 630 1000 1600 2500
Fire Resistance Transmission loss (dB) Transmission loss (dB) 30
Fire Resistance
Transmission loss (dB) Frequency
2500 4000
(Hz) 30 Transmission loss (dB) Frequency
2500 4000
(Hz) (Hz)
30 Frequency (Hz) 30 Frequency (Hz) 30 Frequency (Hz) 30 Frequency
1 hour (UL design no. U448 and 70 70 20 70 1 hour (UL design no. U448 and 20 70
20 20 20 20
ULC design no W433) ULC design no W433)
60 60 Transmission
60 loss (dB) Transmission
60 loss (dB)
Transmission loss (dB)
10 Transmission loss (dB)
10 10 Transmission loss (dB)
10 10 Transmission loss (dB)
10
50 50 70 50 70 50
70
0 70
0 0 70
0 0 70
0
Transmission
60 160 loss (dB)630 1000 1600 2500 4000 Transmission
60 loss (dB)630 1000 1600 2500 4000
40 160 250 400 630 1000 1600 2500 4000
60 40 160 250 400 630 1000 1600 2500 4000
60 40 250
60 160 400
250 400 630 1000 1600 2500 4000 160
60 160 400
40 250 250 400 630 1000 1600 2500 4000
70 70
30 Frequency (Hz) 30 Frequency (Hz) 50 30 Frequency (Hz)
Frequency (Hz) 50 30 Frequency (Hz)
Frequency (Hz)
50 50 50 50
60 60
20 20 40 20 40 20
40 40 40 40
3 Single layer wall Transmission
10
30
loss (dB) Transmission
10
30 6loss (dB)
50
30 10 Single
Transmission
Transmission
30
layer
loss (dB) wall with resilient
loss (dB)
50
Transmission
30 loss (dB)
Transmission
10
30
loss (dB)
1/2” (12.7 mm) gypsum board 70
0
70
0
40
70
20 70
0 metal channels on one side 40
70
20 70
0
20 20 20 20
60 160 250 400 630 1000 1600 2500 4000 60 160 250 400 630 1000 1600 2500 4000 30
60
10 5/8” (15.9 mm) gypsum
60 160 250 400 630 1000 1600 board
2500 4000 30
60
10 60 160 250 400 630 1000 1600 2500 4000
3 5/8” (92 mm) steel studs spaced 10 10 20 10 20 10
50 Frequency (Hz) 50 Frequency (Hz) 50 50 Frequency (Hz) 50 50 Frequency (Hz)
0 0
24” (610 mm) centers 0 0 10 160 0 3 5/8” (92 mm) steel studs spaced 10 160 0
40 160 250 400 630 1000 1600 2500 4000 40 160 250 400 630 1000 1600 2500 4000 40 40 250 400 630 1000 1600 2500 4000 40 40 250 400 630 1000 1600 2500 4000
24”
160 (610
250 mm)400 centers
630 1000 1600 2500 4000 160 250 400 630 1000 1600 2500 4000
Transmission loss (dB)
30 Transmission loss (dB)
30 300 Transmission loss (dB)
30 Frequency (Hz) 300 Transmission loss (dB)
30 Frequency (Hz)
1 1/2” (38 mm) ROCKWOOL AFB ®

70
Frequency (Hz)
70
Frequency (Hz)
160
70 250 400 630 1000 1600 2500 4000
Frequency (Hz) Frequency (Hz)
70 250 400 630 1000 1600 2500 4000
160
20 20 20 20 Resilient metal channels spaced 20 20
Transmission loss (dB) Frequency (Hz) Transmission loss (dB) Frequency (Hz)
Sound Transmission Class 60
Transmission loss (dB)
10
60
Transmission loss (dB)
10 10 60 horizontally
Transmission
10 at 24” (610 mm) centers
loss (dB) 10 60
10
46 (RAL-TL90-195) 50 50 70 50 70 50
70
0 70
0 0 70
0 0 0
Transmission
60 160 3” loss (dB)
(76250
mm) ROCKWOOL AFB ®
Transmission
60 loss (dB)630 1000 1600 2500 4000
40 160 250 400 630 1000 1600 2500 4000
60 40 160 250 400 630 1000 1600 2500 4000
60 40 250
60 160 400 630
4001000
6301600
10002500
16004000
2500 4000 160 160 400
40 250 250 400 630 1000 1600 2500 4000
Fire Resistance Frequency (Hz) Frequency (Hz)
70
50 Frequency (Hz)
Frequency (Hz)
70
50 Frequency (Hz)
Frequency (Hz)
1 hour (UL design no. U448 and
30
50 30
50 60
30
50 Sound Transmission Class 60
30
20 20 40 20 55 (RAL-TL96-289) 40 20
ULC design no W433) 40 40 50 40 50
Transmission loss (dB) Transmission loss (dB) Transmission
30 loss (dB)
Transmission loss (dB) Transmission
30 loss (dB)
10
30 10
30 10
30 10
70 70 40
70 70 Fire Resistance 40
70
0 0 20 0 20 0
20 20 30
60 20 30
60
60 160 250 400 630 1000 1600 2500 4000 60 160 250 400 630 1000 1600 2500 4000 10 60 1160hour250(UL400design no. V417
630 1000 and4000
1600 2500 U465) 10 160 250 400 630 1000 1600 2500 4000
10 10 20 10 20
50 Frequency (Hz) 50 Frequency (Hz) 50
0 50 1 hour (ULC W447) Frequency (Hz) 50
0 Frequency (Hz)
0 0 10 160
40 0 400 630 1000 1600 2500 4000 10 160 250 400 630 1000 1600 2500 4000
40
40 160 250 400 630 1000 1600 2500 4000 40 160 250 400 630 1000 1600 2500 4000 40 250160 250 400 630 1000 1600 2500 4000
4 Single layer wall Transmission loss (dB)
30
70
Frequency (Hz)
Transmission loss (dB)
30
70
Frequency (Hz)
300
20
Transmission
30
160
loss (dB) Frequency (Hz)
70 250 400 630 1000 1600 2500 4000
Frequency (Hz)
300
20
Frequency (Hz)
160 250 400 630 1000 1600 2500 4000
5/8” (15.9 mm) gypsum board 20 20 20
Frequency (Hz) Frequency (Hz)
60 60 Transmission
10 60 loss (dB) Transmission loss (dB)
10
10 10 10
2 1/2” (64 mm) steel studs spaced 50 50
70
0 50
70
0
24” (610 mm) centers
0
40 160 250 400 630 1000 1600 2500 4000
0
7
40 160 250 400 630 1000 1600 2500 4000 60
0 Single
Transmission
160
40 250
loss
400 layer
(dB) wall1600
630 1000 with resilient
2500 4000
160 250 400 630 1000 1600 2500 4000
Transmission
60 160 250loss (dB)630 1000 1600 2500 4000
400
70
50 metal channels on one side
Frequency (Hz)
70
50 Frequency (Hz)
30 Frequency (Hz) 30 Frequency (Hz) 30 Frequency (Hz)
2 1/2” (64 mm) ROCKWOOL AFB ®
60 1/2” (12.7 mm) gypsum board 60
20 20 40 20 40
50
Transmission loss (dB) 50
Transmission loss (dB)
Sound Transmission Class 10 10
30
10 3 5/8” (92 mm) steel studs spaced
30
40
70 40
70
46 (RAL-TL96-270) 0 0
20
0 24” (610 mm) centers
20
30
60 30
60
160 250 400 630 1000 1600 2500 4000 160 250 400 630 1000 1600 2500 4000 10 160 250 400 630 1000 1600 2500 4000 10
Fire Resistance Frequency (Hz) Frequency (Hz)
20
50
0 Resilient metal channelsFrequency spaced(Hz) 20
50
0
1 hour (NBC of Canada 1995 10 160 horizontally
40 250 400 630 at 24”
1000 (610
1600 mm)
2500 4000centers 10 160 250 400 630 1000 1600 2500 4000
40
and UL design no. U448) 300 Frequency (Hz) 300 Frequency (Hz)
160 3”
250(76
400mm)
630ROCKWOOL
1000 1600 2500 AFB
®

20 4000 20 160 250 400 630 1000 1600 2500 4000


Frequency (Hz) Frequency (Hz)
10 Sound Transmission Class 10
0 53 (RAL-TL96-288)
Transmission loss (dB)
0
Transmission
160 250 400 630 1000 1600 2500 4000 160 250loss (dB)630 1000 1600 2500 4000
400
70
Fire Resistance Frequency (Hz) 70
Frequency (Hz)
60 1 hour (UL design no. U448) 60
50 50
40 40
30 30
ROCKWOOL Group ROCKWOOL Group
8
20
9
Return
20 to Commercial Applications
10 10
20 20 20 20
10
60 10
60 10
60
10 10 10 10
0 0 0
50 0 0
50 0 0
50
160 250 400 630 1000 1600 2500 4000 160 250 400 630 1000 1600 2500 4000 40 160 250 400 630 1000
160 250 400 1600 25001600
630 1000 40002500 4000 160 250160400
250630 1000
400 1600
630 10002500
16004000
2500 4000 160 250 400 630 1000 1600 2500 4000
40 40
Construction Description Frequency (Hz) Transmission Loss Frequency (Hz) 30 Construction
Frequency Frequency
(Hz) (Hz) Description Frequency (Hz) (Hz)
Frequency Transmission Loss Frequency (Hz)
30 30
20 20 20
8 Unbalanced
Transmission loss (dB) wall Transmission loss (dB) Transmission
10
Transmission 11
loss (dB) loss (dB)
10
Double
Transmission loss (dB) layer wall Transmission loss (dB)
10
70 5/8” (15.9 mm) gypsum board, single 70 70 70 70 2 layers of 1/2” (12.7 mm) 70
0 0 gypsum board on both sides 0
60 layer one side; double layer other 60 60 60 60 60
160 250 400 630 1000 1600 2500 4000 160 250 400 630 1000 1600 2500 4000 160 250 400 630 1000 1600 2500 4000
50 50 50 50 50 50
Frequency (Hz) 3 1/2” (92 mm) Frequency (Hz)spaced
steel studs Frequency (Hz)
40 3 5/8” (92 mm) steel studs spaced 40 40 40 40 40
24” (610 mm) centers 24” (610 mm) centers
30 30 30 30 30 30
Transmission loss (dB) Transmission loss (dB) Transmission loss (dB)
20 3” (76 mm) ROCKWOOL AFB / ® 20 20
70 20 20
70 1 1/2” (38 mm) ROCKWOOL AFB ®
20
70
10 3 1/2” (89 mm) AFB ®
10 10 10 10 10
60 60
Sound Transmission Class 60
0 0 0
50 0 0
50 0
50
160 Sound
250 400Transmission Class4000
630 1000 1600 2500 160 250 400 630 1000 1600 2500 4000 160 250 400 1600
630 1000 56 (RAL-TL90-196)
160 250 400 630 1000 25001600
40002500 4000 160 250 400 630 1000 1600 2500 4000 160 250 400 630 1000 1600 2500 4000
56 (RAL-TL96-264)Frequency (Hz) Frequency (Hz) 40 Frequency Frequency (Hz) 40 40
30
(Hz)
30 Fire Resistance Frequency (Hz) 30
Frequency (Hz)

Fire Resistance 20 20
2 hours (UL design no. U412 and 20
11/2 hour (NBC of Canada 1995)* Transmission loss (dB) Transmission loss (dB)
V418) Transmission loss (dB)
10
70 10
70 10
70
1 hour (UL design no. V417)
0 0 0
*NB. 3½” (89 mm) AFB only ®
60
160 250 400 630 1000 1600 2500 4000
60
160 250 400 630 1000 1600 2500 4000
60
160 250 400 630 1000 1600 2500 4000
50 50 50
Frequency (Hz) Frequency (Hz) Frequency (Hz)
40 40 40

12
30
Transmission loss (dB) 30
Transmission loss (dB) layer 30
Transmission loss (dB)
Double wall
20
70 20
70 20
70
2 layers of 5/8” (15.9 mm)
9
on loss (dB)
70
Unbalanced
Transmission loss (dB) wall Transmission loss (dB)
70
10
60 Transmission loss (dB)
70
10
60 gypsum board on both sides 10
60
1/2” (12.7 mm) gypsum board, single 0
50 0
50 0
50
60 layer one side; double layer other 60 40
160 250
60 400 630 1000 1600 2500 4000 40
2 1/2”
160 250 400 (64
630mm)
1000 steel studs
1600 2500 spaced
4000
40
160 250 400 630 1000 1600 2500 4000
50 50 50 Frequency (Hz) 24” (610 mm) centers
Frequency (Hz) Frequency (Hz)
30 30 30
40
2 1/2” (64 mm) steel studs spaced 40 40
24” (610 mm) centers
20 20 1 1/2” (38 mm) ROCKWOOL AFB ®
20
30 30 30
10 10 10
on loss (dB) Transmission loss (dB)
20 1 1/2” (38 mm) ROCKWOOL AFB®
Transmission loss (dB)
20 Transmission loss (dB)
20 Sound Transmission Class
70 70 0 70 0 0
10 10 10 400 630 1000 1600 2500 4000
160 250 160 56 400
250 (RAL-TL90-193)
630 1000 1600 2500 4000 160 250 400 630 1000 1600 2500 4000
60
0 Sound Transmission Class 60
0
60
0 Frequency (Hz) Frequency (Hz) Frequency (Hz)
250 400 630 1000 1600 2500 4000 50 160 50 250(RAL-TL90-186)
400 630 1000 1600 2500 4000 50 160 250 400 630 1000 1600 2500 4000 50 160 250 400 630 1000 1600 2500 4000 Fire Resistance
Frequency (Hz) 40 Frequency (Hz) 40 Frequency (Hz) 40 Frequency (Hz)
2 hours (UL design no. U411
30
Fire Resistance 30 30
and V419, NBC of Canada)
on loss (dB)
1 hour
Transmission
(NBC of Canada 1995
loss (dB) Transmission loss (dB) Transmission loss (dB)
20 20 20
70 and UL design no. U448) 70 70
10 10 10
600 600 600
250 400 630 1000 1600 2500 4000 50 160 250 400 630 1000 1600 2500 4000 50 160 250 400 630 1000 1600 2500 4000 50 160 250 400 630 1000 1600 2500 4000

13
Frequency (Hz) Frequency (Hz) Frequency (Hz) Frequency (Hz)
40 Transmission loss
40 (dB) Transmission
40 loss (dB) Double
Transmission loss (dB)layer wall Transmission loss (dB)
30 70 30 70 30 70 2 layersof ½” (12.7 mm) 70
10
on loss (dB) 20 Double
Transmission layer wall
loss (dB)
60
Transmission loss (dB)
20 60
Transmission loss (dB)
20 60 gypsum board on both sides 60
70 2 layers of 5/8” (15.9 mm) 70 70
10 50 10 50 10 50 50
60
0
gypsum board on both sides 60
0
60
0
2 1/2” (64 mm) steel studs spaced
40 40 40 40
250 400 630 1000 1600 2500 4000 50 160 250 400 630 1000 1600 2500 4000 50 160 250 400 630 1000 1600 2500 4000 50 160 250 400 630 1000 1600 2500 4000 24” (610 mm) centers
Frequency (Hz) 40
3 5/8” (92 mm) steel studs spaced
30
Frequency (Hz) 40 Frequency (Hz)
30
40 Frequency (Hz)
30 30
24” (610 mm) centers 20 20 20 1 1/2” (38 mm) ROCKWOOL AFB ®
20
30 30 30
on loss (dB) Transmission loss (dB) 10® Transmission loss (dB) 10 Transmission loss (dB) 10 10
20 3” (76 mm) ROCKWOOL AFB 20 20 Sound Transmission Class
70
10 0 70
10 0 70
10 0 53 (RAL-TL90-185) 0
600 Sound Transmission Class 160 25060 400 630 1000 1600 2500 4000
0
250 400 630 1000 1600 2500 4000
160 60
0
160 250 400 630 1000 1600 2500 4000 160 250 400 630 1000 1600 2500 4000

250 400 630 1000 1600 2500 4000 50 160 57


250(RAL-TL96-268)
400 630 1000 1600 2500 4000
Frequency (Hz)
50 160 250 400 630 1000 1600 2500 4000
Frequency (Hz)
50 160 250 400 630 1000 1600 2500 4000 Fire Resistance Frequency (Hz) Frequency (Hz)
Frequency (Hz) 40 Frequency (Hz) 40 Frequency (Hz) 40 Frequency (Hz) 2 hours (UL design no. U412
Fire Resistance Transmission loss (dB) Transmission loss (dB) Transmission loss
and(dB)
V418) Transmission loss (dB)
30 30 30
on loss (dB)
2 hours (UL design no. U411 70
Transmission loss (dB) Transmission loss (dB) 70 Transmission loss (dB) 70 70
20 20 20
70
and V419, NBC of Canada 1995) 60 70 60 70 60 60
10 10 10
60 50 60 50 60 50 50
0 0 0
250 400 630 1000 1600 2500 4000 50 160 250 400 630 1000 1600 2500 4000 40 50 160 250 400 630 1000 1600 2500 4000 40 50 160 250 400 630 1000 1600 2500 4000 40 40
Frequency (Hz) 40 Frequency (Hz)30 40 Frequency (Hz) 30 40 Frequency (Hz) 30 30
30 ROCKWOOL Group 20 30 20 30 20 ROCKWOOL Group 20
Return to Commercial Applications
on loss (dB) Transmission
20 loss (dB) 10
10 Transmission
20 loss (dB) 10 20 10
11
10
70
10 70
10 10
At the ROCKWOOL Group, we are
committed to enriching the lives of
everyone who comes into contact
with our solutions. Our expertise
is perfectly suited to tackle many of
today’s biggest sustainability and
development challenges, from energy
consumption and noise pollution
to fire resilience, water scarcity and
flooding. Our range of products
reflects the diversity of the world’s
needs, while supporting our
stakeholders in reducing their own
carbon footprint.

Stone wool is a versatile material and


forms the basis of all our businesses.
With more than 11,000 employees
in 39 countries, we are the world
leader in stone wool solutions,
from building insulation to acoustic
ceilings, external cladding systems
to horticultural solutions, engineered
fibres for industrial use to insulation
for the process industry and marine
and offshore.

AFB , CAVITYROCK ,
® ®

COMFORTBATT , CONROCK ,® ®

CURTAINROCK , ROCKBOARD ,
® ®

TOPROCK , MONOBOARD , ROXUL


® ® ®

are registered trademarks of the


ROCKWOOL Group in USA and
ROXUL Inc. in Canada.

ROCKWOOL , COMFORTBOARD ,
™ ™

FABROCK , ROXUL SAFE ,


™ ™

ROCKWOOL PLUS , and AFB evo™ ™

are trademarks of the ROCKWOOL


Group in USA and ROXUL Inc. in
Canada.

SAFE’n’SOUND is a registered
®

Publication date - edition: 01/2018


trademark used under license by
Masonite Inc.

ROCKWOOL
8024 Esquesing Line
Milton, ON L9T 6W3
Tel: 1 800 265 6878
rockwool.com
Return to Commercial Applications
AFB
AFB
®
Technical Data Sheet
® Batt Insulation 07210 & 09820* • Blanket Insulation 07 21 16**
Acoustical Fire Batt Insulation Acoustical Blanket Insulation 09 81 16**

Acoustical Fire Batt Insulation


ROCKWOOL AFB® is a mineral wool batt insulation for interior partitions in commercial constructions where superior
fire resistance and acoustical performance are required.

Performance Test Standard

Mineral Fiber Thermal Insulation for Buildings, Type 1 Compliant CAN/ULC S702

Mineral Fiber Blanket Thermal Insulation, Type 1 Compliant ASTM C665

Compliance Mineral Fiber Blanket Thermal Insulation, Type 7 Compliant ASTM C553

MEA Approval, New York City Approval 338-97-M

City of Los Angeles Approval RR 25444

Flame spread index = 0; Smoke developed index = 0 ASTM E84 (UL 723)

Flame spread index = 0; Smoke developed index = 0 CAN/ULC S102

Reaction to Fire Determination of Non-combustibility of Building Materials - Non-combustible CAN/ULC S114

Behavior of materials at 750°C - Non-combustible ASTM E136

Smolder Resistance - 0.09% CAN/ULC S129

Actual Density at thicknesses ≥ 3” (76.2 mm) - 2.5 lbs/ft³ (40 kg/m³)


Density ASTM C303
Actual Density at thicknesses < 3” (76.2 mm) - 2.8 lbs/ft³ (45 kg/m³)

Stress Corrosion Cracking Tendency of Austenitic Stainless Steel - Passed ASTM C795
Corrosion Resistance
Corrosion of Steel - Passed ASTM C665

Air Erosion Maximum Air Velocity - 1000 fpm (5.08 m/s) UL 181

Thickness 1” through 4” (25.4 mm - 101.6 mm) in 1/2” increments as well as 5” (127 mm) and 6” (152.4 mm)
Dimensions 16” x 48” (413 mm x 1219 mm), 24” x 48” (610 mm x 1219 mm)

Thickness 125 Hz 250 Hz 500 Hz 1000 Hz 2000Hz 4000 Hz NRC ASTM C423
Quiet Spaces
1.0” 0.14 0.25 0.65 0.9 1.01 1.01 0.7
The higher density of ROCKWOOL AFB®
ROCKWOOL AFB is a lightweight, acoustical fire batt
® 1.5” 0.18 0.44 0.94 1.04 1.02 1.03 0.85
can reduce sound transmission, helping to
stone wool insulation specifically designed for steel stud create a quiet and comfortable space. Acoustical Performance 2” 0.28 0.6 1.09 1.09 1.05 1.07 0.95
interior wall and floor applications. Its superior sound 3” 0.52 0.96 1.18 1.07 1.05 1.05 1.05
absorbency and fire protection contribute to the overall
4” 0.86 1.11 1.2 1.07 1.08 1.07 1.1
comfort and safety of occupants.
Please contact ROCKWOOL for STC ratings on tested wall assemblies ASTM E90
It provides increased density that reduces sound
transmission. Greater noise control is further achieved ULC Classification Code: BZJZC
Fire Rated Designs
when AFB® is part of the wall assembly along with gypsum UL Classification Code: BZJZ
boards and resilient channels.

AFB® is non-combustible and will not develop toxic smoke


or promote flame spread, even when directly exposed
to fire. This helps to provide valuable extra time for people
to reach safety and for fire services personnel to control
the spread. It is a key component of fire-rated partitions.
Issued 01-01-18 NOTE: *Master Format 1995 Edition **Master Format 2004 Edition. As ROCKWOOL has no control over installation design and
AFB® comes in a number of thicknesses to meet the Supersedes 08-23-17 workmanship, accessory materials or application conditions, ROCKWOOL does not warranty the performance or results of any
installation containing ROCKWOOL’s products. ROCKWOOL’s overall liability and the remedies available are limited by the general
requirements of both retrofit and new construction terms and conditions of sale. This warranty is in lieu of all other warranties and conditions expressed or implied, including the warranties
applications. of merchantability and fitness for a particular purpose.

Learn more at rockwool.com

8024 Esquesing Line, Milton, ON L9T 6W3


Tel: 800-265-6878 • Fax: 800-991-0110
rockwool.com
ROCKWOOL Group ROCKWOOL Group
13 14
Return to Commercial Applications
AFB evo
AFB evo
™ Technical Data Sheet
™ Batt Insulation 07210 & 09820* • Blanket Insulation 07 21 16**
Acoustical Fire Batt Insulation Acoustical Blanket Insulation 09 81 16**

Acoustical Fire Batt Insulation


ROCKWOOL AFB evo™ is a no added formaldehyde stone wool batt insulation for interior partitions in commercial
constructions where superior fire resistance and acoustical performance is required. ROCKWOOL AFB evo™ is UL
validated to be Formaldehyde Free.

Performance Test Standard

Mineral Fiber Thermal Insulation for Buildings, Type 1 Compliant CAN/ULC S702
Compliance
Mineral Fiber Blanket Thermal Insulation, Type 1 Compliant ASTM C665

Flame spread index = 0; Smoke developed index = 0 ASTM E84 (UL 723)

Flame spread index = 0; Smoke developed index = 0 CAN/ULC S102


Reaction to Fire
Determination of Non-combustibility of Building Materials - Non-combustible CAN/ULC S114

Behavior of materials at 750°C - Non-combustible ASTM E136

Actual Density at thicknesses ≥ 3” (76.2 mm) - 2.5 lbs/ft³ (40 kg/m³)


Density ASTM C303
Actual Density at thicknesses < 3” (76.2 mm) - 2.8 lbs/ft³ (45 kg/m³)

Corrosion Resistance Corrosion of Steel - Passed ASTM C665

Thickness 1” through 4” (25.4 mm - 101.6 mm) in 1/2” increments as well as 5” (127 mm) and 6” (152.4 mm)
Dimensions 16” x 48” (413 mm x 1219 mm), 24” x 48” (610 mm x 1219 mm)

Thickness 125 Hz 250 Hz 500 Hz 1000 Hz 2000Hz 4000 Hz NRC ASTM C423

1.0” 0.14 0.25 0.65 0.9 1.01 1.01 0.7

1.5” 0.18 0.44 0.94 1.04 1.02 1.03 0.85

Acoustical Performance 2” 0.28 0.6 1.09 1.09 1.05 1.07 0.95

3” 0.52 0.96 1.18 1.07 1.05 1.05 1.05

Greener Building 4” 0.86 1.11 1.2 1.07 1.08 1.07 1.1

ROCKWOOL AFB evo is UL validated to be



Please contact ROCKWOOL for STC ratings on tested wall assemblies ASTM E90
ROCKWOOL AFB evo™ is a lightweight, acoustical
Formaldehyde Free and LBC compliant with the
fire batt stone wool insulation for steel stud interior
Declare Product Transparency Label Database. ULC Classification Code: BZJZC
wall and floor applications. This no added formaldehyde Fire Rated Designs
UL Classification Code: BZJZ
insulation provides superior sound absorbency and fire
protection that contribute to the overall comfort and
safety of occupants.

It provides increased density that reduces sound


transmission. Greater noise control is further achieved
when AFB® is part of the wall assembly along with
gypsum boards and resilient channels.
Issued 01-01-18 NOTE: *Master Format 1995 Edition **Master Format 2004 Edition. As ROCKWOOL has no control over installation design and
Supersedes 08-23-17 workmanship, accessory materials or application conditions, ROCKWOOL does not warranty the performance or results of any
AFB evo™ is non-combustible and will not develop installation containing ROCKWOOL’s products. ROCKWOOL’s overall liability and the remedies available are limited by the general
toxic smoke or promote flame spread, even when terms and conditions of sale. This warranty is in lieu of all other warranties and conditions expressed or implied, including the warranties
of merchantability and fitness for a particular purpose.
directly exposed to fire. This helps to provide valuable
extra time for people to reach safety and for fire services
personnel to control the spread. It is a key component
of fire-rated partitions.

AFB evo™ comes in a number of thicknesses to


meet the requirements of both retrofit and new
construction applications.

Learn more at rockwool.com

8024 Esquesing Line, Milton, ON L9T 6W3


Tel: 800-265-6878 • Fax: 800-991-0110
rockwool.com
ROCKWOOL Group ROCKWOOL Group
15 16
Return to Commercial Applications
CURTAIN WALL SYSTEMS

CURTAINROCK
®

and ROXUL SAFE


Insulation for Curtain Wall Systems

Return to Commercial Applications


Superior Protection and Fire Resistance
CURTAINROCK is non-combustible and fire-resistant,
®

Performance in a Curtain Wall System and will not develop smoke or promote flame spread
when exposed to fire, providing a critical line of defense
in fire protection.

✔ Fire Resistant ROCKWOOL stone wool products have an extremely high


This unique vapor permeable melting point of 2150 °F (1177 °C). When used
quality
✔ of ROCKWOOL’s
Long-Term Stable R-Value in combination with ROXUL SAFE , CURTAINROCK 40 ™ ®

curtain wall insulation allows and CURTAINROCK 80 provide a comprehensive


®

✔ Sound Absorbent fire-stopping system that has been UL/ULC/Intertek


for an increased potential for
tested and approved for perimeter fire containment
drying
✔ Waterwithout
Repellenttrapping water
systems.
in the wall assembly.
✔ Environmentally Sustainable

ROXUL SAFE ™ Temperature Development in a


ROXUL SAFE is a lightweight, semi-rigid stone wool
™ Standard Fire (ASTM E119)
insulation that provides fire-stopping and acoustical 2400–
properties. It is designed to fill perimeter gaps between –1200
Components: Concrete Floor Slab, ROXUL SAFE™ , 2000– stone wool
concrete floor slabs and exterior wall systems, between Fire sealant, Mullion cover – CURTAINROCK®, melts –1000
firewalls and ceiling slabs, and around conduit pipes and Transom, Stiffeners, Spandrel panel.

Temperature (ºC)
Temperature (ºF)
duct openings through walls and floor slabs. 1600–
–800
It is non-combustible and fire resistant, and will not 1200– fiberglass melts
–600
develop toxic smoke or promote flame spread, even
when exposed directly to a fire. When ROXUL SAFE ™
800– –400
is used with CURTAINROCK 40/80, it provides a
®

comprehensive fire-stopping system that has been 400– –200


UL/ULC/Intertek tested and approved for perimeter fire CURTAINROCK ® Designed by James K. M. Cheng Architects Inc., the
visually stunning Living Shangri-La hotel, located
containment systems. CURTAINROCK is a lightweight, semi-rigid stone wool
®

0– –0 on the Vancouver waterfront, was built using


insulation board designed for curtain wall systems. 0 2 4 6 8 CURTAINROCK® and ROXUL SAFE™ products as its
ROXUL SAFE is always used in conjunction with a

ROCKWOOL offers CURTAINROCK , CURTAINROCK 40, ® ®
Time (Hours) specified insulation.
fire sealant to prevent passage of fire and smoke from and CURTAINROCK 80 to meet a wide variety of curtain
®

one floor to the next. wall specifications.

Product Specifications Fire Performance


Product Dimensions W x L Thickness Product Specification Test Result

1" 1.5" 2" 3" 4" 5" 6" ROXUL SAFE™,


       CURTAINROCK® ASTM E136 Behaviour of Materials at 750 °C (1382 °F) Non-Combustible
24” x 48” (610 mm x 1219 mm)
CURTAINROCK®* CURTAINROCK® 40/80
24” x 60” (610 mm x 1524 mm) 
ROXUL SAFE™,
24” x 48” (610 mm x 1219 mm)     CURTAINROCK® CAN4 S114 Test for Non-Combustibility Non-Combustible
24" x 60" (610 mm xx 1524 mm)  CURTAINROCK® 40/80
CURTAINROCK® 40
36” x 60” (914 mm x 1524 mm)    ROXUL SAFE™,
ASTM E 84(UL 723) and Flame Spread = 0
CURTAINROCK® Surface Burning Characteristics
48” x 72” (1219 mm x 1829 mm)   CAN/ULC S102 Smoke Developed = 0
CURTAINROCK® 40/80
24” x 48” (610 mm x 1219 mm)    
CURTAINROCK® 40/80 ASTM E2307/E119 Perimeter Fire Barrier Systems Complies
CURTAINROCK 80®
36” x 60” (914 mm x 1524 mm)   
48” x 72” (1219 mm x 1829 mm)    ROXUL SAFE™ CAN4 S115M Standard Test Method/Fire Stop Systems Complies

ROXUL SAFE™ 24” x 48” (610 mm x 1219 mm)   


ROXUL SAFE™ CAN/ULC-S129 Smoulder Resistance 0.01%

* Canada only
** Custom sizes available
ROCKWOOL Group ROCKWOOL Group
18 19
Return to Commercial Applications
Thermal Resistance Minimizing Noise with
The R-value of ROCKWOOL insulation will not change
Superior Sound Absorption
over time because stone wool is not produced with
blowing agents, which off-gas and result in lower thermal CURTAINROCK demonstrates superior sound
®

performance. Not only is the thermal performance of attenuation characteristics. The unique multi-
ROCKWOOL insulation maintained over its lifetime, directional fiber structure and high density effectively
but the wall’s thermal performance remains consistent traps and dissipates sound waves, reducing noise
because ROCKWOOL products are dimensionally stable. transmission into and out of the building.

ROCKWOOL insulation will not expand or contract due to ROXUL SAFE shares the same unique fiber structure

temperature variances in the curtain wall system. and density, also allowing for greater sound
These attributes result in optimal thermal performance attenuation.
of a building envelope.

Developer Monterey Park used ROCKWOOL


CURTAINROCK Acoustical Performance
®

CURTAINROCK® insulation for its recently opened


ASTM C 423 CO-EFFICIENTS AT FREQUENCIES
75,000 sq. ft. commerical building in Brampton,
Ontario. 125 250 500 1000 2000 4000
Thickness NRC
Hz Hz Hz Hz Hz Hz
Thermal Performance
2" 0.26 0.68 1.12 1.10 1.03 1.04 1.00
Product Specification Test Result 3" 0.63 0.95 1.14 1.01 1.03 1.04 1.05

4.2 hr.ft2.F/Btu 4" 1.03 1.07 1.12 1.04 1.07 1.08 1.10
CURTAINROCK®
R-Value / inch @ 75oF 0.74 m2K/W
ASTM C518 (C177)
RSI value / 25.4 mm @ 24oC 4.3 hr.ft2.F/Btu
CURTAINROCK® 40/80
0.75 m2K/W

CURTAINROCK 40 – Acoustical Performance


®

ASTM C 423 CO-EFFICIENTS AT FREQUENCIES

125 250 500 1000 2000 4000


Thickness NRC
Hz Hz Hz Hz Hz Hz

2" 0.26 0.71 1.14 1.09 1.04 1.03 1.00

3" 0.65 0.94 1.13 1.07 1.06 1.04 1.10

4" 0.92 1.04 1.07 1.07 1.07 1.08 1.05


In addition to superior sound absorption properties,
ROCKWOOL CURTAINROCK® and ROXUL SAFE™ are
Putting on the Ritz frequently specified for a variety of commercial curtain
wall applications.
The elegant and post-modern 53 storey Ritz-
Carlton hotel/condominium in Toronto was built
using more than 30,000 sq.ft of CURTAINROCK®
and ROXUL SAFE™ insulation.ROCKWOOL
insulation is recognized and trusted by top ROXUL SAFE – Acoustical Performance

CURTAINROCK 80 – Acoustical Performance
®

architects and contractors across North America


ASTM C 423 CO-EFFICIENTS AT FREQUENCIES ASTM C 423 CO-EFFICIENTS AT FREQUENCIES
who specify our products for energy efficiency,
sustainability, fire protection, water resistance, 125 250 500 1000 2000 4000 125 250 500 1000 2000 4000
Thickness NRC Thickness NRC
and sound control.Rumenest asitate labo. Elit Hz Hz Hz Hz Hz Hz Hz Hz Hz Hz Hz Hz
pliat od magnimus dollatiora ex et dolo ea 2" 0.26 0.68 1.12 1.10 1.03 1.04 1.00 2" 0.39 0.84 1.08 1.01 1.02 1.01 1.00
voluptam nate verchic ientisto optatur molupta
ssimaio omnis sanisint verum voluptatem 3" 0.63 0.95 1.14 1.01 1.03 1.04 1.05 3" 0.68 0.92 1.08 1.03 1.03 1.03 1.10

4" 1.03 1.07 1.12 1.04 1.07 1.08 1.10 4" 1.00 0.95 1.06 1.04 1.06 1.08 1.05

ROCKWOOL Group ROCKWOOL Group


20 21
Return to Commercial Applications
Excellent Moisture
Management Features

Facing Options To Meet Any


Application Requirement
ROCKWOOL CURTAINROCK products are available
®

with or without reinforced foil facing (RFF). For


example, CURTAINROCK 80 RFF is often used in
®

fire rated assemblies, for aesthetics behind glass,


This unique vapor permeable and as a vapor barrier. CURTAINROCK 40 and
®

This unique
quality vapor permeable
of ROCKWOOL’s curtain CURTAINROCK 80 are approved for use as a
®

quality
wall of ROCKWOOL’s
insulation allows for ancurtain component in UL/ULC/Intertek classified perimeter
wall insulation allows for an
increased potential for drying fire containment systems.
ROCKWOOL CURTAINROCK and ® increased
without potential
trapping forin
water drying
the
ROXUL SAFE are inorganic and

without trapping
wall assembly. water in the
therefore do not rot, corrode or wall assembly.
promote fungi, mold and bacterial
growth.

Both CURTAINROCK and ®

ROXUL SAFE are water repellent,


yet vapor permeable (30-40 perms).


These products resist the infiltration
of water into the insulation layer and Carnegie 57, also known
facilitate the drainage of water out as One57, is a 75-story
of the system to enhance the drying
potential of curtain wall assemblies.
skyscraper in New York
City. Due for completion in
2013, it will be the fourth
tallest building in the city.
CURTAINROCK 80 RFF is
®

specified throughout the


Moisture Resistance curtain wall system
of this architectural jewel.
Product Specification Test Result

CURTAINROCK ,
®

ASTM C 1104 Moisture Sorption 0.01%


CURTAINROCK® 40

ROXUL SAFE™,
ASTM C 1104 Moisture Sorption 0.04%
CURTAINROCK® 80

Corrosive Resistance
Product Specification Test Result

CURTAINROCK®
ASTM C 665 Corrosiveness to Steel Pass
CURTAINROCK® 40/80

Stainless Steel Stress Corrosion Specification as per Test


CURTAINROCK® Methods C871 and C692: U.S. Nuclear Regulatory Commission,
ASTM C 795 Conforms
CURTAINROCK® 40/80 Reg. Guide #1.36: U.S. Military Specifications MIL-I-24244
(all versions including B and C)

ROCKWOOL Group ROCKWOOL Group


22 23
Return to Commercial Applications
At the ROCKWOOL Group, we are
committed to enriching the lives of
everyone who comes into contact
with our solutions. Our expertise
is perfectly suited to tackle many of
today’s biggest sustainability and
development challenges, from energy
consumption and noise pollution
to fire resilience, water scarcity and
flooding. Our range of products
reflects the diversity of the world’s
needs, while supporting our
stakeholders in reducing their own
carbon footprint.

Stone wool is a versatile material and


forms the basis of all our businesses.
With more than 11,000 employees
in 39 countries, we are the world
leader in stone wool solutions,
from building insulation to acoustic
ceilings, external cladding systems
to horticultural solutions, engineered
fibres for industrial use to insulation
for the process industry and marine
and offshore.

AFB , CAVITYROCK ,
® ®

COMFORTBATT , CONROCK ,® ®

CURTAINROCK , ROCKBOARD ,
® ®

TOPROCK , MONOBOARD , ROXUL


® ® ®

are registered trademarks of the


ROCKWOOL Group in USA and
ROXUL Inc. in Canada.

ROCKWOOL , COMFORTBOARD ,
™ ™

FABROCK , ROXUL SAFE ,


™ ™

ROCKWOOL PLUS , and AFB evo™ ™

are trademarks of the ROCKWOOL


Group in USA and ROXUL Inc. in
Canada.

SAFE’n’SOUND is a registered
®

Publication date - edition: 01/2018


trademark used under license by
Masonite Inc.

ROCKWOOL
8024 Esquesing Line
Milton, ON L9T 6W3
Tel: 1 800 265 6878
rockwool.com
Return to Commercial Applications
CURTAINROCK ®
CURTAINROCK
Technical Data Sheet
® Board Insulation 07210* • Board Insulation 07 21 13**
Curtain wall & glazed assemblies 08 44 00**
Curtain Wall Insulation
Curtain Wall Insulation
ROCKWOOL CURTAINROCK® is a semi-rigid, mineral wool insulation board designed for backpan systems
in curtain wall applications.

Performance Test Standard

Compliance Mineral Fiber Block and Board Thermal Insulation - Type IVA Compliant ASTM C612

Flame spread index = 0; Smoke developed index = 0 ASTM E84 (UL 723)
Flame spread index = 0; Smoke developed index = 0 CAN/ULC S102
Reaction to Fire Determination of Non Combustibility of Building Materials - Non Combustible CAN/ULC S114
Test for Non-Combustibility - Non Combustible ASTM E136
Hot Surface Performance - 1200°F ASTM C411

Density Actual Density - 3.5 lbs/ft³ (56 kg/m³) ASTM C303

Dimensional Stability Linear Shrinkage - < 2 % @ 1200°F ASTM C356

Stress Corrosion Cracking Tendency of Austenitic Stainless Steel - Passed ASTM C795
Corrosion Resistance
Corrosion of Steel - Passed ASTM C665

R-Value / inch @ 75oF 4.2 hr.ft2.F/Btu ASTM C518 (C177)


Thermal Resistance RSI value / 25.4 mm @ 24oC 0.74 m2K/W

Moisture Sorption - 0.01% ASTM C1104


Reaction to Moisture Water Vapor Transmission, Desiccant Method - 1805ng/Pa.s.m2 (32 perm) ASTM E96
Determination of Fungi Resistance - Passed ASTM C1338

Thickness Product is available in 1” through 5” offerings (25.4 mm - 127 mm)


Dimensions 24” x 48” (610 mm x 1219 mm)

Thickness 125 Hz 250 Hz 500 Hz 1000 Hz 2000Hz 4000 Hz NRC ASTM C423

2” 0.26 0.68 1.12 1.1 1.03 1.04 1


Acoustical Performance
3” 0.63 0.95 1.14 1.01 1.03 1.04 1.05

A better fit 4” 1.03 1.07 1.12 1.04 1.07 1.08 1.1

CURTAINROCK is easy to fabricate,


®

ROCKWOOL CURTAINROCK® is a lightweight, cut and install, ensuring an optimal fit. Issued 01-01-18 NOTE: *Master Format 1995 Edition **Master Format 2004 Edition. As ROCKWOOL has no control over installation design and workmanship, accessory
materials or application conditions, ROCKWOOL does not warranty the performance or results of any
semi-rigid stone wool insulation board designed Supersedes 08-23-17 installation containing ROCKWOOL’s products. ROCKWOOL’s overall liability and the remedies available are limited by the general
specifically for use in curtain wall systems, and is best terms and conditions of sale. This warranty is in lieu of all other warranties and conditions expressed or implied, including the warranties
of merchantability and fitness for a particular purpose.
suited for backpan or mechanical fastening applications.

CURTAINROCK® is non-combustible and fire resistant,


and will not develop toxic smoke or promote flame
spread, even when exposed directly to a fire.

ROCKWOOL insulation has excellent acoustic


properties and because the products are dimensionally
stable, they maintain thermal performance over
their lifetime, even in rising and falling temperatures.
This contributes to the optimal performance of a
building envelope.

ROCKWOOL offers a variety of curtain wall specifications.


Products are also available with or without reinforced
foil facing (RFF).

Learn more at rockwool.com

8024 Esquesing Line, Milton, ON L9T 6W3


Tel: 800-265-6878 • Fax: 800-991-0110
rockwool.com
ROCKWOOL Group ROCKWOOL Group
25 26
Return to Commercial Applications
CURTAINROCK ® 40
CURTAINROCK 40
Technical Data Sheet
® Board Insulation 07210* • Board Insulation 07 21 13**
Curtain wall & glazed assemblies 08 44 00**
Curtain Wall Insulation
Curtain Wall Insulation
ROCKWOOL CURTAINROCK® 40 is a semi-rigid, mineral wool insulation board designed for fire rated curtain
wall applications.

Performance Test Standard

Mineral Fiber Block and Board Thermal Insulation - Type IVB Compliant ASTM C612
Compliance
MEA Approval, New York City Approval 331-97-M

Flame spread index = 0; Smoke developed index = 0 ASTM E84 (UL 723)
Flame spread index = 0; Smoke developed index = 0 CAN/ULC S102
Determination of Non Combustibility of Building Materials - Non Combustible CAN/ULC S114
Reaction to Fire
Test for Non-Combustibility - Non Combustible ASTM E136
Hot Surface Performance - 1200°F ASTM C411
Perimeter Fire Barrier Systems - Consult UL Directory ASTM E2307/E119

Density Nominal Density, Minimum - 4.0 lbs/ft³ (64 kg/m³) ASTM C303

Dimensional Stability Linear Shrinkage - < 1 % @ 1200°F ASTM C356

Stress Corrosion Cracking Tendency of Austenitic Stainless Steel - Passed ASTM C795
Corrosion Resistance
Corrosion of Steel - Passed ASTM C665

R-Value / inch @ 75oF 4.3 hr.ft2.F/Btu ASTM C518 (C177)


Thermal Resistance RSI value / 25.4 mm @ 24oC 0.75 m2K/W

Moisture Sorption - 0.01% ASTM C1104


Reaction to Moisture
Determination of Fungi Resistance - Passed ASTM C1338

Thickness Product is available in 2” through 4” offerings (50.8 mm - 101.6 mm)


Dimensions 24” x 48” (610 mm x 1219 mm) and 48” x 72” (1219 mm x 1829 mm)
Facing Product is available with a reinforced foil facer

Fire Resistance
Together CURTAINROCK® and ROXUL SAFE™
ROCKWOOL CURTAINROCK® 40 is a stone wool are UL/ULC/Intertek approved for perimeter Issued 01-01-18 NOTE: *Master Format 1995 Edition **Master Format 2004 Edition. As ROCKWOOL has no control over installation design and
insulation board designed for a variety of curtain wall fire containment systems. Supersedes 08-23-17 workmanship, accessory materials or application conditions, ROCKWOOL does not warranty the performance or results of any
systems. CURTAINROCK® is non-combustible and fire installation containing ROCKWOOL’s products. ROCKWOOL’s overall liability and the remedies available are limited by the general
terms and conditions of sale. This warranty is in lieu of all other warranties and conditions expressed or implied, including the warranties
resistant, and will not develop toxic smoke or promote of merchantability and fitness for a particular purpose.
flame spread, even when exposed directly to a fire.

When CURTAINROCK® 40 is used with ROCKWOOL


ROXUL SAFE™, they provide a comprehensive fire-stopping
system that has been UL/ULC/Intertek tested and approved
for perimeter fire containment systems.

ROCKWOOL insulation has excellent acoustic properties


and are dimensionally stable – maintaining thermal
performance over their lifetime, even in rising and
falling temperatures. This contributes to the optimal
performance of a building envelope.

CURTAINROCK® products are available with or without


reinforced foil facing (RFF).

Learn more at rockwool.com

8024 Esquesing Line, Milton, ON L9T 6W3


Tel: 800-265-6878 • Fax: 800-991-0110
rockwool.com
ROCKWOOL Group ROCKWOOL Group
27 28
Return to Commercial Applications
CURTAINROCK ® 80
CURTAINROCK 80
Technical Data Sheet
® Board Insulation 07210* • Board Insulation 07 21 13**
Curtain wall & glazed assemblies 08 44 00**
Curtain Wall Insulation
Curtain Wall Insulation
ROCKWOOL CURTAINROCK® 80 is a rigid, mineral wool insulation board designed for fire rated curtain
wall applications.

Performance Test Standard

Mineral Fiber Block and Board Thermal Insulation - Type IVB Compliant ASTM C612
Compliance
MEA Approval, New York City Approval 331-97-M

Flame spread index = 0; Smoke developed index = 0 ASTM E84 (UL 723)
Flame spread index = 0; Smoke developed index = 0 CAN/ULC S102
Determination of Non Combustibility of Building Materials - Non Combustible CAN/ULC S114
Reaction to Fire
Test for Non-Combustibility - Non Combustible ASTM E136
Hot Surface Performance - 1200°F ASTM C411
Perimeter Fire Barrier Systems - Consult UL Directory ASTM E2307/E119

Density Nominal Density - 8.0 lbs/ft³ (128 kg/m³) ASTM C303

Dimensional Stability Linear Shrinkage - < 1 % @ 1200°F ASTM C356

Stress Corrosion Cracking Tendency of Austenitic Stainless Steel - Passed ASTM C795
Corrosion Resistance
Corrosion of Steel - Passed ASTM C665

R-Value / inch @ 75oF 4.3 hr.ft2.F/Btu ASTM C518 (C177)


Thermal Resistance RSI value / 25.4 mm @ 24oC 0.75 m2K/W

Moisture Sorption - 0.04% ASTM C1104


Reaction to Moisture
Determination of Fungi Resistance - Passed ASTM C1338

Thickness Product is available in 1” through 5” offerings (25.4 mm - 127 mm)


Dimensions 24” x 48” (610 mm x 1219 mm) and 48” x 72” (1219 mm x 1829 mm)
Facing Product is available with a reinforced foil facer

Fire Resistance
Together CURTAINROCK® and ROXUL SAFE™
ROCKWOOL CURTAINROCK® 80 is a stone wool are UL/ULC/Intertek approved for perimeter
insulation board designed for a variety of curtain wall fire containment systems. Issued 01-01-18 NOTE: *Master Format 1995 Edition **Master Format 2004 Edition. As ROCKWOOL has no control over installation design and
Supersedes 08-23-17 workmanship, accessory materials or application conditions, ROCKWOOL does not warranty the performance or results of any
systems. CURTAINROCK® is non-combustible and fire installation containing ROCKWOOL’s products. ROCKWOOL’s overall liability and the remedies available are limited by the general
resistant, and will not develop toxic smoke or promote terms and conditions of sale. This warranty is in lieu of all other warranties and conditions expressed or implied, including the warranties
of merchantability and fitness for a particular purpose.
flame spread, even when exposed directly to a fire.

When CURTAINROCK® 80 is used with ROCKWOOL


ROXUL SAFE™, they provide a comprehensive fire-stopping
system that has been UL/ULC/Intertek tested and approved
for perimeter fire containment systems.

ROCKWOOL insulation has excellent acoustic properties


and is dimensionally stable – maintaining thermal
performance over their lifetime, even in rising and
falling temperatures. This contributes to the optimal
performance of a building envelope.

CURTAINROCK® products are available with or without


reinforced foil facing (RFF).

Learn more at rockwool.com

8024 Esquesing Line, Milton, ON L9T 6W3


Tel: 800-265-6878 • Fax: 800-991-0110
rockwool.com
ROCKWOOL Group ROCKWOOL Group
29 30
Return to Commercial Applications
ROXUL SAFE™
ROXUL SAFE
Technical Data Sheet

Firestopping 07840* • Firestopping 07 84 00**
Fire Safing Insulation Fibrous Fire Safing 07 84 56.13** • Curtain wall & glazed assemblies 08 44 00**

Fire Safing Insulation


ROCKWOOL ROXUL SAFE™ is semi-rigid, mineral wool batt insulation approved for use in fire rated joints,
through penetrations and perimeter fire containment systems.

Performance Test Standard

Mineral Fiber Block and Board Thermal Insulation - Type IVA Compliant ASTM C612
Compliance
MEA Approval, New York City Approval 339-97-M

Flame spread index = 0; Smoke developed index = 0 ASTM E84 (UL 723)
Flame spread index = 0; Smoke developed index = 0 CAN/ULC S102
Determination of Non Combustibility of Building Materials - Non Combustible CAN/ULC S114
Test for Non-Combustibility - Non Combustible ASTM E136
Fire Tests of Firestop Systems CAN/ULC S115
Reaction to Fire
Fire Tests of Penetration Firestop Systems ASTM E814 (UL 1479)
Tests for Fire Resistance of Building Joint Systems UL 2079
Perimeter Fire Barrier Systems ASTM E2307/E119
Smoulder Resistance - 0.01% CAN/ULC S129
Consult UL, ULC and Intertek Directories for fire rated designs

Density Actual Density - 4.5 lbs/ft³ (72 kg/m³) ASTM C303

Stress Corrosion Cracking Tendency of Austenitic Stainless Steel - Passed ASTM C795
Corrosion Resistance
Corrosion of Steel - Passed ASTM C665

Moisture Sorption by weight - 0.04% ASTM C1104


Reaction to Moisture
Determination of Fungi Resistance - Passed ASTM C1338

Thickness Product is available in 2”, 3” and 4” (50.8 mm, 76.2 mm and 101.6 mm)
Dimensions 24” x 48” (610 mm x 1219 mm)

Fire-stopping Material
ROXUL SAFE™ is always used in conjunction Issued 01-01-18 NOTE: *Master Format 1995 Edition **Master Format 2004 Edition. As ROCKWOOL has no control over installation design and
ROCKWOOL ROXUL SAFE™ is a lightweight, semi-rigid with a fire sealant to prevent passage of fire Supersedes 08-23-17 workmanship, accessory materials or application conditions, ROCKWOOL does not warranty the performance or results of any
installation containing ROCKWOOL’s products. ROCKWOOL’s overall liability and the remedies available are limited by the general
stone wool insulation that provides fire-stopping and and smoke from one area to the next. terms and conditions of sale. This warranty is in lieu of all other warranties and conditions expressed or implied, including the warranties
acoustical properties. It is designed to fill perimeter gaps of merchantability and fitness for a particular purpose.
between concrete floor slabs and exterior wall systems,
between firewalls and ceiling slabs, and around conduit
pipes and duct openings through walls and floor slabs.

It is non-combustible and fire resistant, and will not


develop toxic smoke or promote flame spread, even
when exposed directly to a fire. When ROXUL SAFE™
is used with CURTAINROCK® 40/80, it provides a
comprehensive fire-stopping system that has been
UL/ULC/Intertek tested and approved for perimeter
fire containment systems.

ROXUL SAFE™ also helps to increase energy efficiency,


improve thermal stability and reduce noise transmission
into and out of the building for overall occupant comfort.

Learn more at rockwool.com

8024 Esquesing Line, Milton, ON L9T 6W3


Tel: 800-265-6878 • Fax: 800-991-0110
rockwool.com
ROCKWOOL Group ROCKWOOL Group
31 32
Return to Commercial Applications
MULTIPURPOSE BOARD INSULATION

ROCKBOARD 40/60/80
®

Premium Multipurpose Board Insulation


for Acoustic/Thermal Applications

Return to Commercial Applications


ROCKWOOL ROCKBOARD Provides Thermal Integrity &
®

Superior Sound Absorption Moisture Control


Acoustic Performance Thermal Integrity Water Repellent Insulation – Will not Rot, Corrode,
ROCKWOOL stone wool insulation products are specified for high acoustical performance. There are two Stone wool is naturally denser than fiberglass, Promote Mold or Bacterial Growth
physical characteristics that support this result. One is the multi-directional fiber orientation, the other is the and will maintain its dimensional integrity under all Moisture can cause a number of structural and/or
density of the products. conditions. It will not slump, shrink, expand with aesthetic problems within commercial buildings.
temperature fluctuations or compress under light As an integral part of any building design, proper
ROCKBOARD products and applications are available in various densities to support different applications.
®

loads as competitive insulations are prone to do. ventilation is necessary to allow any built-up condensation
ROCKBOARD 60 in particular has exceptional energy absorbing characteristics and is effective at reducing sound
®

to drain out of the system. ROCKBOARD stone wool


®

transmission across a wide range of frequencies. insulation is water repellent, helping to deflect moisture
Thermal Resistance away from the surface, alleviating potential issues.

ROCKBOARD® 40 R-value/inch @ 75 °F 4.2 hr.ft2.F/BTU ROCKBOARD insulation is inorganic, and will not rot,
®

ASTM C518 (C177) RSI value/25.4 mm @ 24 °C 0.74 m2K/W corrode, or promote fungi or bacteria growth, which
means the potential for related environmental health
ROCKBOARD 40 – Acoustical Performance
®
ROCKBOARD® 60 R-value/inch @ 75 °F 4.3 hr.ft2.F/BTU issues is also mitigated as a result.
ASTM C518 (C177) RSI value/25.4 mm @ 24 °C 0.75 m2K/W

ROCKBOARD® has superior acoustic ASTM C423 CO-EFFICIENTS AT FREQUENCIES

properties making it ideal for theaters, 125 250 500 1000 2000 4000
ROCKBOARD® 80
ASTM C518 (C177)
R-value/inch @ 75 °F
RSI value/25.4 mm @ 24 °C
4.0 hr.ft2.F/BTU
0.70 m2K/W
recording studios and other sound
Thickness NRC
Hz Hz Hz Hz Hz Hz

damping applications. 2.0" 0.26 0.68 1.12 1.10 1.03 1.04 1.00

3.0" 0.63 0.95 1.14 1.01 1.03 1.04 1.05

4.0" 1.03 1.07 1.12 1.04 1.07 1.08 1.10

ROCKBOARD 60 – Acoustical Performance


®

ASTM C423 CO-EFFICIENTS AT FREQUENCIES

125 250 500 1000 2000 4000


Thickness NRC
Hz Hz Hz Hz Hz Hz

2.0" 0.32 0.81 1.06 1.02 0.99 1.04 0.95

3.0" 0.78 0.89 1.04 0.98 1.01 1.02 1.00

Moisture Resistance
ROCKBOARD 80 – Acoustical Performance
®

ROCKBOARD® 40/60/80
ASTM C423 CO-EFFICIENTS AT FREQUENCIES Moisture Sorption < 0.08%
ASTM C1104

125 250 500 1000 2000 4000


Thickness NRC
Hz Hz Hz Hz Hz Hz
ROCKBOARD® is ideal for maintaining
Fungi Resistance
1.0" 0.11 0.31 0.82 1.01 1.02 1.01 0.80 thermal integrity and moisture control in
2.0" 0.43 0.78 0.90 0.97 0.97 1.00 0.90 interior applications. ROCKBOARD® 40/60/80 Determination of
Passed
ASTM C1338 Fungi Resistance
3.0" 0.75 0.82 0.89 0.94 1.00 1.00 .90

ROCKWOOL Group ROCKWOOL Group


34 35
Return to Commercial Applications
ROCKBOARD Products and Applications
®

Fire Resistant Insulation – Protecting


Product Density Thicknesses WXL Common Applications

ROCKBOARD® 40 4 lb/ft3 (64kg/m3) 2”, 2.5”, 3”, 4” 24” x 48” Mechanical/Utility rooms

both the Building and the Occupants ROCKBOARD® 60 6 lb/ft3 (96kg/m3) 2”, 3”, 3.5”, 4” 24” x 48”
Theaters, Recording studios,
Metal roofs requiring snow load

Surfaces requiring wind load


ROCKBOARD® 80 8 lb/ft3 (128kg/m3) 1”, 1.5”, 2”, 3”, 4” 24” x 48”
(e.g. substrate for stucco walls)
Fire Resistance Fire Performance
ROCKBOARD products are non-combustible.
®

ROCKWOOL stone wool has an extremely high melting ROCKBOARD® 40/60/80 Test for Non- Facing Options
Non-Combustible
point of 2150 °F (1177 °C) compared to fiberglass at CAN/ULC S114 Combustibility Facing can help to obtain optimum thermal and energy efficiency, structural integrity, and enhanced interior aesthetics
~1112 °F (~600 °C), thermoplastic insulation at 160-600 with minimal cost impact on the overall project. ROCKBOARD can be surfaced with a variety of facings to deliver the
®

°F (~70-315 °C). ROCKBOARD products do not produce


®

desired result. Please contact your ROCKWOOL sales representative for our complete facing offering and technical
®
Surface
toxic smoke in the event of a fire and are an excellent ROCKBOARD® 40/60/80
Burning
Flame Spread = 0
information related to materials, permeability, light reflectance, and fire performance. Fire Resistant Insulation –
ASTM E84 (UL723) Smoke Developed = 0
barrier against the spread of flames to help protect Characteristics Protecting both the Building and the Occupants.
occupants and reduce property damage.
ROCKBOARD® 40/60/80 Surface Burning Flame Spread = 0
CAN/ULC S102 Characteristics Smoke Developed = 0

Temperature Development Dimensional Stability


in a Standard Fire (ASTM E119)
ROCKBOARD® 40
Linear Shrinkage
0.47 % @ 1200 °F ROCKBOARD® has excellent sound-
damping characteristics making it ideal for
ASTM C356 (650 °C)
2400–
–1200 buffering the hum from noisy mechanical
1.14 % @ 1200 °F
rooms.
ROCKBOARD® 60
2000– stone wool ASTM C356
Linear Shrinkage
(650 °C)
melts –1000
Temperature (ºC)
Temperature (ºF)

1600–
–800 ROCKBOARD® 80
Linear Shrinkage
0. 41 % @ 1200 °F
ASTM C356 (650 °C)
1200– fiberglass melts
–600
800– –400

400– polyurethane foam burns –200 Compressive Strength


polystyrene foam melts
@10% @25%
0– –0
0 2 4 6 8
ROCKBOARD® 40
Time (Hours) 90 psf (4.3 kPa) 226 psf (10.8 kPa)
ASTM C165

ROCKBOARD® 60
196 psf (9.4 kPa) 547 psf (26.2 kPa)
In an application where elevated temperatures are a ASTM C165
concern, stone wool will provide greater protection than
fiberglass. The maximum service temperature of stone ROCKBOARD® 80
353 psf (16.9 kPa) 794 psf (38 kPa)
ASTM C165
wool insulation when tested to ASTM C411 is 1200 ºF (650
ROCKBOARD adds an extra degree of fire
®

ºC), compared to fiberglass which is limited to a maximum


resistance around utility rooms.
service temperature of 450 ºF (232 ºC).

Compliance and Performance


ROCKBOARD® 40 Mineral Fiber Block and Type IVA,
Maximum Service Temperature ASTM C612 Board Thermal Insulation Complies

ROCKBOARD® 40/60/80 ASTM C411 Hot Surface Performance In Compliance with ASTM C612 @ 1200 °F (650 °C) ROCKBOARD® 60/80 Mineral Fiber Block and Type IVB,
ASTM C612 Board Thermal Insulation Complies

ROCKWOOL Group ROCKWOOL Group


36 37
Return to Commercial Applications
At the ROCKWOOL Group, we are
committed to enriching the lives of
everyone who comes into contact
with our solutions. Our expertise
is perfectly suited to tackle many of
today’s biggest sustainability and
development challenges, from energy
consumption and noise pollution
to fire resilience, water scarcity and
flooding. Our range of products
reflects the diversity of the world’s
needs, while supporting our
stakeholders in reducing their own
carbon footprint.

Stone wool is a versatile material and


forms the basis of all our businesses.
With more than 11,000 employees
in 39 countries, we are the world
leader in stone wool solutions,
from building insulation to acoustic
ceilings, external cladding systems
to horticultural solutions, engineered
fibres for industrial use to insulation
for the process industry and marine
and offshore.

AFB , CAVITYROCK ,
® ®

COMFORTBATT , CONROCK ,® ®

CURTAINROCK , ROCKBOARD ,
® ®

TOPROCK , MONOBOARD , ROXUL


® ® ®

are registered trademarks of the


ROCKWOOL Group in USA and
ROXUL Inc. in Canada.

ROCKWOOL , COMFORTBOARD ,
™ ™

FABROCK , ROXUL SAFE ,


™ ™

ROCKWOOL PLUS , and AFB evo™ ™

are trademarks of the ROCKWOOL


Group in USA and ROXUL Inc. in
Canada.

SAFE’n’SOUND is a registered
®

Publication date - edition: 01/2018


trademark used under license by
Masonite Inc.

ROCKWOOL
8024 Esquesing Line
Milton, ON L9T 6W3
Tel: 1 800 265 6878
rockwool.com
Return to Commercial Applications
ROCKBOARD 40
ROCKBOARD 40
®
Technical Data Sheet
®
Board Insulation 07210* • Board Insulation 07 21 13**
Multipurpose Board Insulation Acoustic Board Insulation 09 81 13**

Multipurpose Board Insulation


ROCKWOOL ROCKBOARD® 40 is a semi-rigid, multi-purpose mineral wool insulation board.

Performance Test Standard

Compliance Mineral Fiber Block and Board Thermal Insulation - Type IVA Compliant ASTM C612

Flame spread index = 0; Smoke development index = 0 ASTM E84 (UL 723)
Flame spread index = 0; Smoke development index = 0 CAN/ULC S102
Reaction to Fire Behaviour of materials at 750°C - Non Combustible CAN/ULC S114
Test for Non-Combustibility - Non Combustible ASTM E136
Hot Surface Performance - 1200°F ASTM C411

Density Actual Density - 4 lbs/ft³ (64 kg/m³) ASTM C303

Dimensional Stability Linear Shrinkage - <1% @ 1200°F ASTM C356

Stress Corrosion Cracking Tendency of Austenitic Stainless Steel - Passed ASTM C795
Corrosion Resistance
Corrosion of Steel - Passed ASTM C665

R-Value / inch @ 75oF 4.2 hr.ft2.F/Btu ASTM C518 (C177)


Thermal Resistance RSI value / 25.4 mm @ 24oC 0.74 m2K/W

Moisture Sorption by weight - 0.03% ASTM C1104


Reaction to Moisture
Determination of Fungi Resistance - Passed ASTM C1338

90psf (4.3kPa) @ 10% compression ASTM C165


Compressive Strength
225psf (10.8kPa) @ 25% compression

Air Erosion Maximum Air Velocity 1000 fpm (5.08 m/s) UL 181

Thickness Product is available in 1” through 4” offerings (25.4 mm - 101.6 mm)


Dimensions 24” x 48” (610 mm x 1219 mm)

Thickness 125 Hz 250 Hz 500 Hz 1000 Hz 2000Hz 4000 Hz NRC ASTM C423

1.0” 0.07 0.32 0.77 1.04 1.05 1.05 0.8


Superior Acoustic Properties 1.5” 0.18 0.48 0.96 1.09 1.05 1.05 0.9
Acoustical Performance
Excellent sound-dampening characteristics 2” 0.26 0.68 1.12 1.1 1.03 1.04 1
ROCKWOOL ROCKBOARD® 40 is a premium, multi-purpose make ROCKBOARD® products ideal for
stone wool insulation board used in walls, ceilings and 3” 0.63 0.95 1.14 1.01 1.03 1.04 1.05
buffering the hum from noisy mechanical rooms.
floors for acoustic and thermal applications. 4” 1.03 1.07 1.12 1.04 1.07 1.08 1.1

ROCKBOARD® 40 is non-combustible and fire resistant,


and will not produce toxic smoke or promote flame
spread, even when exposed directly to a fire. This can NOTE: *Master Format 1995 Edition **Master Format 2004 Edition. As ROCKWOOL has no control over installation design and workmanship, accessory
Issued 01-01-18
add an extra degree of fire resistance and contribute Supersedes 08-23-17
materials or application conditions, ROCKWOOL does not warranty the performance or results of any
installation containing ROCKWOOL’s products. ROCKWOOL’s overall liability and the remedies available are limited by the general
to occupant protection. terms and conditions of sale. This warranty is in lieu of all other warranties and conditions expressed or implied, including the warranties
of merchantability and fitness for a particular purpose.
ROCKBOARD® products also maintain dimensional
integrity under all conditions and, as a result, will not
slump, shrink or expand with temperature.

ROCKBOARD® products can be surfaced with different


facings to achieve optimal performance results. From
mechanical rooms to sound studios to utility rooms,
these products add a high-performance barrier to
noise and fire.

Learn more at rockwool.com

8024 Esquesing Line, Milton, ON L9T 6W3


Tel: 800-265-6878 • Fax: 800-991-0110
rockwool.com
Return to Commercial Applications
ROCKBOARD 60
ROCKBOARD 60
Technical Data Sheet
®

®
Board Insulation 07210* • Board Insulation 07 21 13**
Multipurpose Board Insulation Acoustic Board Insulation 09 81 13**

Multipurpose Board Insulation


ROCKWOOL ROCKBOARD® 60 is a rigid, multi-purpose mineral wool insulation board.

Performance Test Standard

Compliance Mineral Fiber Block and Board Thermal Insulation - Type IVB Compliant ASTM C612

Flame spread index = 0; Smoke development index = 0 ASTM E84 (UL 723)
Flame spread index = 0; Smoke development index = 0 CAN/ULC S102
Reaction to Fire
Behaviour of materials at 750°C - Non Combustible CAN/ULC S114
Hot Surface Performance - 1200°F ASTM C411

Density Actual Density - 6 lbs/ft³ (96 kg/m³) ASTM C303

Dimensional Stability Linear Shrinkage - <1% @ 1200°F ASTM C356

Stress Corrosion Cracking Tendency of Austenitic Stainless Steel - Passed ASTM C795
Corrosion Resistance
Corrosion of Steel - Passed ASTM C665

R-Value / inch @ 75oF 4.3 hr.ft2.F/Btu ASTM C518 (C177)


Thermal Resistance RSI value / 25.4 mm @ 24oC 0.75 m2K/W

Moisture Sorption by weight - 0.07% ASTM C1104


Reaction to Moisture
Determination of Fungi Resistance - Passed ASTM C1338

355psf (17kPa) @ 10% compression ASTM C165


Compressive Strength
585psf (28kPa) @ 25% compression

Thickness Product is available in 2” through 4” offerings (50.8 mm - 101.6 mm)


Dimensions 24” x 48” (610 mm x 1219 mm)

Thickness 125 Hz 250 Hz 500 Hz 1000 Hz 2000Hz 4000 Hz NRC ASTM C423

Acoustical Performance 2” 0.32 0.81 1.06 1.02 0.99 1.04 0.95

3” 0.78 0.89 1.04 0.98 1.01 1.02 1

Superior Acoustic Properties


Excellent sound-dampening characteristics
ROCKWOOL ROCKBOARD® 60 is a premium, multi-purpose make ROCKBOARD® products ideal for
stone wool insulation board used in walls, ceilings and Issued 01-01-18 NOTE: *Master Format 1995 Edition **Master Format 2004 Edition. As ROCKWOOL has no control over installation design and
buffering the hum from noisy mechanical rooms. Supersedes 08-23-17 workmanship, accessory materials or application conditions, ROCKWOOL does not warranty the performance or results of any
floors for acoustic and thermal applications. installation containing ROCKWOOL’s products. ROCKWOOL’s overall liability and the remedies available are limited by the general
terms and conditions of sale. This warranty is in lieu of all other warranties and conditions expressed or implied, including the warranties
of merchantability and fitness for a particular purpose.
ROCKBOARD® 60 is non-combustible and fire resistant,
and will not produce toxic smoke or promote flame
spread, even when exposed directly to a fire. This can
add an extra degree of fire resistance and contribute
to occupant protection.

ROCKBOARD® products also maintain dimensional


integrity under all conditions and, as a result, will not
slump, shrink or expand with temperature.

ROCKBOARD® products can be surfaced with different


facings to achieve optimal performance results.
From mechanical rooms to sound studios to utility
rooms, these products add a high-performance barrier
to noise and fire.

Learn more at rockwool.com

8024 Esquesing Line, Milton, ON L9T 6W3


Tel: 800-265-6878 • Fax: 800-991-0110
rockwool.com
Return to Commercial Applications
ROCKBOARD 80
ROCKBOARD 80
®
Technical Data Sheet
® Board Insulation 07210* • Board Insulation 07 21 13**
Multipurpose Board Insulation Acoustic Board Insulation 09 81 13**

Multipurpose Board Insulation


ROCKWOOL ROCKBOARD® 80 is a rigid, multi-purpose mineral wool insulation board.

Performance Test Standard

Compliance Mineral Fiber Block and Board Thermal Insulation - Type IVB Compliant ASTM C612

Flame spread index = 0; Smoke developed index = 0 ASTM E84 (UL 723)
Flame spread index = 0; Smoke developed index = 0 CAN/ULC S102
Reaction to Fire
Determination of Non Combustibility of Building Materials - Non Combustible CAN/ULC S114
Hot Surface Performance - 1200°F ASTM C411

Density Actual Density - 8 lbs/ft³ (128 kg/m³) ASTM C303

Dimensional Stability Linear Shrinkage - <1% @ 1200°F ASTM C356

Stress Corrosion Cracking Tendency of Austenitic Stainless Steel - Passed ASTM C795
Corrosion Resistance
Corrosion of Steel - Passed ASTM C665

R-Value / inch @ 75oF 4.0 hr.ft2.F/Btu ASTM C518 (C177)


Thermal Resistance RSI value / 25.4 mm @ 24oC 0.70 m2K/W

Moisture Sorption by weight - 0.05% ASTM C1104


Reaction to Moisture
Determination of Fungi Resistance - Passed ASTM C1338

439psf (21kPa) @ 10% compression ASTM C165


Compressive Strength
1065psf (50kPa) @ 25% compression

Thickness Product is available in 2” through 4” offerings (50.8 mm - 101.6 mm)


Dimensions 24” x 48” (610 mm x 1219 mm)

Thickness 125 Hz 250 Hz 500 Hz 1000 Hz 2000Hz 4000 Hz NRC ASTM C423

Acoustical Performance 2” 0.43 0.78 0.9 0.97 0.97 1 0.9

3” 0.75 0.82 0.89 0.94 1 1 0.9

Superior Acoustic Properties


Excellent sound-dampening characteristics
ROCKWOOL ROCKBOARD® 80 is a premium, multi-purpose make ROCKBOARD® products ideal for
stone wool insulation board used in walls, ceilings and buffering the hum from noisy mechanical rooms.
floors for acoustic and thermal applications.

ROCKBOARD® 80 is non-combustible and fire resistant, Issued 01-01-18 NOTE: *Master Format 1995 Edition **Master Format 2004 Edition. As ROCKWOOL has no control over installation design and
and will not produce toxic smoke or promote flame Supersedes 08-23-17 workmanship, accessory materials or application conditions, ROCKWOOL does not warranty the performance or results of any
installation containing ROCKWOOL’s products. ROCKWOOL’s overall liability and the remedies available are limited by the general
spread, even when exposed directly to a fire. This can terms and conditions of sale. This warranty is in lieu of all other warranties and conditions expressed or implied, including the warranties
add an extra degree of fire resistance and contribute of merchantability and fitness for a particular purpose.

to occupant protection.

ROCKBOARD® products also maintain dimensional


integrity under all conditions and, as a result, will not
slump, shrink or expand with temperature.

ROCKBOARD® products can be surfaced with


different facings to achieve optimal performance results.
From mechanical rooms to sound studios to utility rooms,
these products add a high-performance barrier to noise
and fire.

Learn more at rockwool.com

8024 Esquesing Line, Milton, ON L9T 6W3


Tel: 800-265-6878 • Fax: 800-991-0110
rockwool.com
Return to Commercial Applications
PRE-ENGINEERED METAL BUILDINGS

ROXUL SAFE 55 & 65


and ROCKWOOL PLUS MB


Insulation for Pre-Engineered Metal Buildings

Return to Commercial Applications


Exterior Wall Insulation for Assemblies for Zero Lot Line
Pre-Engineered Metal Buildings and Exterior Wall Applications

ROXUL SAFE 55 & 65 and ROCKWOOL PLUS MB


™ ™
Basic Concept of a Fire Rated Wall Featuring ROCKWOOL PLUS MB is a lightweight,

are non-combustible, high-densityinsulation products ROXUL SAFE 55 & 65 Insulation in the Wall Assembly

non-combustible, semi-rigid blanket insulation, designed
for interior and exterior wallsin pre-engineered metal ROXUL SAFE 55 & 65 are non-combustible, rigid stone

for metal building construction where
building construction.This stone wool insulation is made wool insulation boards that provide added fire protection an hourly fire rating is not required.
from natural stone and recycled content, providing for metal buildings in close proximity.
ROXUL SAFE 55 & 65 are designed for interior or
™ Insulating buildings with ROCKWOOL PLUS MB ™

exceptional fire-resistance and energy-saving properties.


exterior non-load bearing metal panel wall assemblies will help increase energy efficiency, improve thermal
While similar in thermal insulating properties,each
where a fire resistance rating is required. stability, and enhance fire protection for the overall
product is designed for specific building applications.
comfort and safety of occupants.
ROCKWOOL offers the option of one or two hour, single
That’s why ROCKWOOL PLUS MB is the insulation

side or double sided fire rated assemblies.


of choice for today’s green builders in commercial
construction.

Components: Exterior Metal Cladding, ROXUL SAFE™ 55 or 65,


Z-Bar Girts, Ceramic Fire Blanket (Z-Girt Cover), Flashing Channels, Wall and
Partition Facings/Accessories

ROXUL SAFE™ 55 & 65 and ROCKWOOL PLUS™ MB Note: For ULC Designs W610 and W611 ceramic strips required on two sides. For
products are used to insulate walls in pre-engineered actual designs please reference UL/ULC Directories. Components: Exterior Metal Cladding, ROCKWOOL PLUS™ MB,
Z-Bar Girts, Flashing Channels, Wall and Partition Facings/Accessories
metal buildings. ROXUL SAFE™ 55 & 65 are ideally
suited for zero lot line applications where buildings are
in close proximity and fire safety is essential.
Top View
These products also provide superior performance
in acoustic assemblies, as well as in applications
for mechanical equipment isolation and insulation.

Complete Wall Assembly 12” min. overlap

ROCKWOOL Group ROCKWOOL Group


46 47
Return to Commercial Applications
Fire Resistance High-Performance Insulation
Designed for Pre-Engineered
ROXUL SAFE 55, ROXUL SAFE 65 and™ ™
Metal Buildings
ROCKWOOL PLUS MB are non-combustible, able

to withstand temperatures up to 2150ºF (1177ºC), and


do not produce smoke or propagate flames, providing
a critical line of defense in fire protection. Energy-Saving Thermal Performance
The excellent thermal properties of
These products provide high temperature fire protection, ROCKWOOL PLUS MB, ROXUL SAFE 55 and
™ ™

particularly when a fire separation wall is required ROXUL SAFE 65 contribute to energy efficient building

envelopes helping to reduce ongoing energy costs.


ROXUL SAFE 55 & 65’s fire resistance ratings allow
™ ROCKWOOL PLUS MB delivers consistent thermal

builders to reduce the required separation and increase performance across the board in metal building wall
the area of buildings in close proximity to each other. construction, maintaining an R-value of R4. ROXUL SAFE ™

65 and ROXUL SAFE 55 maintain R-values of R4.2 and


R4.3, respectively.

Temperature Development in a Standard


Fire (ASTM E119)

2400–
–1200 ROXUL SAFE™ 55 & 65 are able to withstand the
2000– stone wool
intense heat of fire approaching 2150ºF (1177ºC)
melts –1000 Superior Sound Absorption
without melting or burning. They are specifically
Temperature (ºC)
Temperature (ºF)

1600– ROXUL SAFE 55, ROXUL SAFE 65 and


™ ™

–800 designed to meet building codes in high density


ROCKWOOL PLUS MB demonstrate superior sound

areas where buildings are in close proximity.


1200– fiberglass melts
–600 attenuation characteristics. The unique multi-directional
fiber structure and high density effectively trap and
800– –400 dissipate sound waves reducing noise transmission into
and out of the building.
400– –200

0– –0
0 2 4 6 8
Time (Hours)

Water Repellent
The structure and integrity of ROCKWOOL insulation
Fire-Rated Exterior Non-Load Bearing Sheet Steel Walls are not affected by the presence of water. The product is
water repellent, resisting the infiltration of water into the
Product Fire Resistance Rating Fire Protection UL Design No. ULC Design No. Thickness* WxL system. It is compatible with air/vapor barrier systems to
provide an extra layer of protection against moisture and
24” x 48”
thermal transfer. The product is inorganic and therefore
From 1 Side U654 W605 (610 x 1220 mm)
does not rot, corrode, or promote fungi, mold and
3” (76 mm) 31.5” x 48” bacterial growth.
ROXUL SAFE™ 65 1HR
*Contact (2 layers) (800 x 1220 mm)
From 2 Sides ROCKWOOL W610
Technical Services 32” x 48”
(813 x 1220 mm)

24” x 48”
From 1 Side U655 W606 (610 x 1220 mm)

4” (102 mm) 31.5” x 48”


ROXUL SAFE™ 55 2HR
*Contact (2 layers) (800 x 1220 mm)
From 2 Sides ROCKWOOL W611
Technical Services 32” x 48”
(813 x 1220 mm)

*ROXUL SAFE™ 65 & ROXUL SAFE™ 55 products are installed using 2 layers of 3” or 4” material respectively.

ROCKWOOL Group ROCKWOOL Group


48 49
Return to Commercial Applications
ROXUL SAFE 55 & 65 Technical Data

ROCKWOOL PLUS MB Technical Data

Compliance and Performance Compliance and Performance


Standard Specification for Mineral Fiber Blanket
ASTM C612 Mineral Fiber Block and Board Thermal Insulation Type IVB, Complies ASTM C553 Thermal Insulation for Commercial and Industrial Type I, II, III
Applications

Fire Performance
Fire Performance

CAN/ULC S411 Test for Non-Combustibility Non-Combustible Flame Spread = 0


CAN/ULC S102 Surface Burning Characteristics
Smoke Developed = 0
Flame Spread = 0
CAN/ULC S102 Surface Burning Characteristics Flame Spread = 0
Smoke Developed = 0 ASTM E84 (UL 723) Surface Burning Characteristics
Smoke Developed = 0

Maxiumum Service Temperature CAN4-S114 Determination of Non-Combustibility Non-Combustible

In Compliance with
ASTM C411 Hot Surface Performance
ASTM C612 @ 1200°F (650°C) Maximum Service Temperature

Dimensional Stability ASTM C411 Maximum Recommended Use Temperature 450°F (232°C)

ASTM C356 Linear Shrinkage 1% @ 1200°F (650°C)


Dimensional Stability

Moisture Resistance ASTM C356 Linear Shrinkage 0.74 % @ 450°F (232°C)

ASTM C1104 Moisture Sorption 0.04%


Moisture Resistance

Thermal Resistance ASTM C1104 Water Vapor Sorption 0.028%

ROXUL SAFE 65

R-value/inch @75ºF 4.2 hf. ft . F/BTU
2

ASTM C518 (C 177) RSI value/25.4 mm @25ºC 0.74 m2K/W


Thermal Resistance
ROXUL SAFE 55

R-value/inch @75ºF 4.3 hf. ft . F/BTU
2

ASTM C518 (C 177) RSI value/25.4 mm @25ºC 0.76 m2K/W R-value/inch @ 75°F 4.0 hf. ft2. F/BTU
ASTM C518 (C177)
RSI value/25.4 mm @ 24°C 0.71 m2K/W

Corrosive Resistance
Corrosive Resistance
ASTM C665 Corrosiveness to Steel Pass
ASTM C665 Corrosiveness to Steel Pass
Stainless Steel Stress Corrosion Specification as
per Test Methods C871 and C692: U.S. Nuclear Stainless Steel Stress Corrosion Specification as
ASTM C795 Regulatory Commission, Reg. Guide #1.36: U.S. Conforms per Test Methods C871 and C692: U.S. Nuclear
Military Specifications – 24244 ASTM C795 Regulatory Commission, Reg. Guide #1.36: U.S. Conforms
(all versions including B and C) Military Specifications MIL-I-24244
(all versions including B and C)
Dimensions
Dimensions
24” W x 48” L (610 mm x 1219 mm)
31.5” W x 48” L (800 mm x 1219 mm) 24” W x 48” L
32” W x 48” L (813 mm x 1219 mm) Product thickness available in 2” through 4” in ½" increments as well as 5” and 6” offerings.
(610 mm W x 1219 mm L)

Thickness
Density
ROXUL SAFE 65

3” (76 mm) Thickness
2.0 lbs/sq.ft.3
ROXUL SAFE™ 55 4” (102 mm) Thickness ASTM C612-00
32 kg/m3

ROCKWOOL Group ROCKWOOL Group


50 51
Return to Commercial Applications
At the ROCKWOOL Group, we are
committed to enriching the lives of
everyone who comes into contact
with our solutions. Our expertise
is perfectly suited to tackle many of
today’s biggest sustainability and
development challenges, from energy
consumption and noise pollution
to fire resilience, water scarcity and
flooding. Our range of products
reflects the diversity of the world’s
needs, while supporting our
stakeholders in reducing their own
carbon footprint.

Stone wool is a versatile material and


forms the basis of all our businesses.
With more than 11,000 employees
in 39 countries, we are the world
leader in stone wool solutions,
from building insulation to acoustic
ceilings, external cladding systems
to horticultural solutions, engineered
fibres for industrial use to insulation
for the process industry and marine
and offshore.

AFB , CAVITYROCK ,
® ®

COMFORTBATT , CONROCK ,® ®

CURTAINROCK , ROCKBOARD ,
® ®

TOPROCK , MONOBOARD , ROXUL


® ® ®

are registered trademarks of the


ROCKWOOL Group in USA and
ROXUL Inc. in Canada.

ROCKWOOL , COMFORTBOARD ,
™ ™

FABROCK , ROXUL SAFE ,


™ ™

ROCKWOOL PLUS , and AFB evo™ ™

are trademarks of the ROCKWOOL


Group in USA and ROXUL Inc. in
Canada.

SAFE’n’SOUND is a registered
®

Publication date - edition: 01/2018


trademark used under license by
Masonite Inc.

ROCKWOOL
8024 Esquesing Line
Milton, ON L9T 6W3
Tel: 1 800 265 6878
rockwool.com
Return to Commercial Applications
ROXUL SAFE™ 55
ROXUL SAFE 55
Technical Data Sheet

Board Insulation 05080* • Board Insulation 07 21 13**
Metal Building Insulation Metal Wall Panels 07 42 13**

Metal Building Insulation


ROCKWOOL ROXUL SAFE™ 55 is a mineral wool insulation board approved for use in metal building assemblies
where a 2-hour fire resistance rating is required from one side or both sides of the wall.

Performance Test Standard

Compliance Mineral Fiber Block and Board Thermal Insulation - Type IVB Compliant ASTM C612

Flame spread index = 0; Smoke developed index = 0 ASTM E84 (UL 723)
Flame spread index = 0; Smoke developed index = 0 CAN/ULC S102
Determination of Non Combustibility of Building Materials - Non Combustible CAN/ULC S114
Test for Non-Combustibility - Non Combustible ASTM E136
Reaction to Fire ULC 2 hr rated from interior side - W606
ULC 2 hr rated from both sides - W611
UL 2 hr rated from interior side - U655
UL 2 hr rated from both sides - U659
Consult UL and ULC Directories for fire rated designs

Density Nominal Density, Minimum - 4.5 lbs/ft³ (72 kg/m³) ASTM C303

R-Value / inch @ 75 F o
4.2 hr.ft2.F/Btu ASTM C518 (C177)
Thermal Resistance RSI value / 25.4 mm @ 24oC 0.74 m2K/W

Dimensional Stability Linear Shrinkage - <1% @ 1200°F ASTM C356

Stress Corrosion Cracking Tendency of Austenitic Stainless Steel - Passed ASTM C795
Corrosion Resistance
Corrosion of Steel - Passed ASTM C665

Moisture Sorption by weight - 0.04% ASTM C1104


Reaction to Moisture
Determination of Fungi Resistance - Passed ASTM C1338

Thickness Product is available in 4” thickness (101.6 mm)


Dimensions 24” x 48” (610 mm x 1219 mm), 31.5” x 48” (800 mm x 1219 mm), 32” x 48” (813 mm x 1219 mm)

Fire-resistant Material
A 2-hour fire resistance rating from the interior
ROCKWOOL ROXUL SAFE™ 55 is a medium-density stone side allows builders to reduce the required
wool insulation for exterior and interior non-load-bearing, separation between buildings.
steel-faced firewall applications where a fire resistance Issued 01-01-18 NOTE: *Master Format 1995 Edition **Master Format 2004 Edition. As ROCKWOOL has no control over installation design and
Supersedes 08-23-17 workmanship, accessory materials or application conditions, ROCKWOOL does not warranty the performance or results of any
rating is required. It is approved for use in a 2-hour fire installation containing ROCKWOOL’s products. ROCKWOOL’s overall liability and the remedies available are limited by the general
terms and conditions of sale. This warranty is in lieu of all other warranties and conditions expressed or implied, including the warranties
rated system. of merchantability and fitness for a particular purpose.

Designed to meet building codes in high-density areas,


ROXUL SAFE™ 55 is non-combustible, withstanding
temperatures up to 2150°F (1177°C), and will not produce
toxic smoke or promote flame spread. As a result,
it provides high-temperature fire protection, enhancing
occupant safety, particularly when a fire separation wall
is required.

It is also UL/ULC tested and approved for fire-rated


assemblies.

ROCKWOOL offers single- or double-sided fire-rated


assemblies. ROXUL SAFE™ 55 is ideally suited for zero
lot line applications where buildings are in close proximity
and fire safety is essential.

Learn more at rockwool.com

8024 Esquesing Line, Milton, ON L9T 6W3


Tel: 800-265-6878 • Fax: 800-991-0110
rockwool.com
Return to Commercial Applications
ROXUL SAFE™ 65
ROXUL SAFE 65
Technical Data Sheet

Board Insulation 15080* • Board Insulation 07 21 013**
Metal Building Insulation Metal Wall Panels 07 42 13**

Metal Building Insulation


ROCKWOOL ROXUL SAFE™ 65 is a mineral wool insulation board approved for use in metal building assemblies
where a 1-hour fire resistance rating is required from one side or both sides of the wall.

Test Stand-
Performance
ard
Compliance Mineral Fiber Block and Board Thermal Insulation - Type IVB Compliant ASTM C612

Flame spread index = 0; Smoke developed index = 0 ASTM E84 (UL 723)
Flame spread index = 0; Smoke developed index = 0 CAN/ULC S102
Determination of Non Combustibility of Building Materials - Non Combustible CAN/ULC S114
Test for Non-Combustibility - Non Combustible ASTM E136
Reaction to Fire ULC 1 hr rated from interior side - W605
ULC 1 hr rated from both sides - W610
UL 1 hr rated from interior side - U654
UL 1 hr rated from both sides - U658
Consult UL and ULC Directories for fire rated designs

Density Nominal Density, Minimum - 6.0 lbs/ft³ (96 kg/m³) ASTM C303

R-Value / inch @ 75oF 4.2 hr.ft2.F/Btu ASTM C518 (C177)


Thermal Resistance RSI value / 25.4 mm @ 24oC 0.74 m2K/W

Dimensional Stability Linear Shrinkage - <1% @ 1200°F ASTM C356

Stress Corrosion Cracking Tendency of Austenitic Stainless Steel - Passed ASTM C795
Corrosion Resistance
Corrosion of Steel - Passed ASTM C665

Moisture Sorption by weight - 0.04% ASTM C1104


Reaction to Moisture
Determination of Fungi Resistance - Passed ASTM C1338

Thickness Product is available in 3” thickness (76.2mm)


Dimensions 24” x 48” (610 mm x 1219 mm), 31.5” x 48” (800 mm x 1219 mm), 32” x 48” (813 mm x 1219 mm)

Fire-resistant Material
A 1-hour fire resistance rating from the interior
ROCKWOOL ROXUL SAFE™ 65 is a medium-density side allows builders to reduce the required
stone wool insulation for exterior and interior non-load- separation between buildings.
bearing, steel-faced firewall applications where a fire
resistance rating is required. It is approved for use in Issued 01-01-18 NOTE: *Master Format 1995 Edition **Master Format 2004 Edition. As ROCKWOOL has no control over installation design and
Supersedes 08-23-17 workmanship, accessory materials or application conditions, ROCKWOOL does not warranty the performance or results of any
a 1-hour fire-rated system. installation containing ROCKWOOL’s products. ROCKWOOL’s overall liability and the remedies available are limited by the general
terms and conditions of sale. This warranty is in lieu of all other warranties and conditions expressed or implied, including the warranties
of merchantability and fitness for a particular purpose.
Designed to meet building codes in high-density areas,
ROXUL SAFE™ 65 is non-combustible, withstanding
temperatures up to 2150°F (1177°C), and will not produce
toxic smoke or promote flame spread. As a result,
it provides high-temperature fire protection, enhancing
occupant safety, particularly when a fire separation wall
is required.

It is also UL/ULC tested and approved for fire-rated


assemblies.

ROCKWOOL offers single- or double-sided fire-rated


assemblies. ROXUL SAFE™ 65 is ideally suited for zero lot
line applications where buildings are in close proximity
and fire safety is essential.

Learn more at rockwool.com

8024 Esquesing Line, Milton, ON L9T 6W3


Tel: 800-265-6878 • Fax: 800-991-0110
rockwool.com
Return to Commercial Applications
ROCKWOOL PLUS MB
ROCKWOOL PLUS MB
™ Technical Data Sheet
™ Batt Insulation 07810 • Blanket Insulation 07 21 16**
Pre-engineered Metal Building Insulation Metal Wall Panels 07 42 13**

Pre-engineered Metal Building Insulation


ROCKWOOL PLUS™ MB is a mineral wool insulation batt designed for use in pre-engineered metal
building constructions.

Performance Test Standard

Compliance Mineral Fiber Blanket Thermal Insulation, Type I, II and III ASTM C553

Flame spread index = 0; Smoke developed index = 0 ASTM E84 (UL 723)

Flame spread index = 0; Smoke developed index = 0 CAN/ULC S102


Reaction to Fire
Determination of Non Combustibility of Building Materials - Non Combustible CAN/ULC S114

Behaviour of materials at 750°C - Non Combustible ASTM E136

Density Actual Density - 2 lbs/ft³ (32 kgs/m³) ASTM C303

R-Value / inch @ 75 F o
4.0 hr.ft2.F/Btu
Thermal Resistance RSI value / 25.4 mm @ 24oC 0.70 m2K/W ASTM C518 (C177)

Stress Corrosion Cracking Tendency of Austenitic Stainless Steel - Passed ASTM C795
Corrosion Resistance
Corrosion of Steel - Passed ASTM C665

Moisture Sorption - 0.03% ASTM C1104


Reaction to Moisture
Determination of Fungi Resistance - Passed ASTM C1338

Thickness 2” through 4” (50.8 mm - 101.6 mm) in 1/2” increments as well as 5” (127 mm) and 6” (152.4 mm)
Dimensions 24” x 48” (610 mm x 1219 mm)

Thickness 125 Hz 250 Hz 500 Hz 1000 Hz 2000Hz 4000 Hz NRC ASTM C423

2.5” 0.34 0.76 1.12 1.05 1.04 1.04 1


Acoustical Performance
3.5” 0.56 0.99 1.17 1.04 1.05 1.05 1.05

6” 1.17 1.2 1.16 1.08 1.08 1.07 1.15


Energy-saving Thermal Performance
Maintaining an R-value of R4,
ROCKWOOL PLUS™ MB is a lightweight, semi-rigid ROCKWOOL PLUS™ MB delivers
mineral wool batt insulation designed for pre-engineered consistent thermal performance,
metal building construction where an hourly fire rating is Issued 01-01-18 NOTE: *Master Format 1995 Edition **Master Format 2004 Edition. As ROCKWOOL has no control over installation design and
contributing to energy-efficient Supersedes 08-23-17 workmanship, accessory materials or application conditions, ROCKWOOL does not warranty the performance or results of any
not required. for pre-engineered metal building. installation containing ROCKWOOL’s products. ROCKWOOL’s overall liability and the remedies available are limited by the general
terms and conditions of sale. This warranty is in lieu of all other warranties and conditions expressed or implied, including the warranties
of merchantability and fitness for a particular purpose.
It is non-combustible and fire resistant, and will not
produce toxic smoke or promote flame spread. As a
result, it provides high-temperature fire protection,
particularly when a fire separation wall is required.

ROCKWOOL PLUS™ MB also helps to increase energy


efficiency and improve thermal stability. Strong and
durable onsite, it is easy to cut and install, and can
contribute to earning LEED® points.

This product is recommended for installation on the


interior side of a watertight metal cladding. It is not
recommended for use in a rainscreen or cavity wall
application where it may be exposed to the elements
during construction or in situ.

Learn more at rockwool.com

8024 Esquesing Line, Milton, ON L9T 6W3


Tel: 800-265-6878 • Fax: 800-991-0110
rockwool.com
ROCKWOOL Group ROCKWOOL Group
57 58
Return to Commercial Applications
Residential
Applications
COMFORTBATT ®

Thermal Batt Insulation Brochure

COMFORTBATT ®

Technical Data Sheet

SAFE’n’SOUND ®

Fire and Sound proofing Brochure

SAFE’n’SOUND ®

Technical Data Sheet

ROXUL SAFE 45 ™

Residential Party Wall


Technical Data Sheet

COMFORTBOARD 80 ™

Technical Data Sheet Continuous Insulation

Click on any of the above brochures or data


sheets to be directed to that specific document.

Visit www.rockwool.com for our full


Product Documentation Library.
THERMAL BATT INSULATION

COMFORTBATT
®

Thermal Batt Insulation for


Residential & Commercial Construction.

FPO

Return to Residential Applications


Superior building envelope performance
by ROCKWOOL Insulation.
Performance Matters.
Managing moisture in wall assemblies Better fit equals better wall performance
Depending on your building codes and geographic To ensure the labeled R-value is achieved, batt insulation
ROCKWOOL COMFORTBATT® is a semi-rigid batt insulation location, a vapor barrier may be required when insulating in wood and steel stud wall cavities must be gap free
exterior wall cavities. The use of a vapor retarder will limit and void free. Gaps and voids are most prevalent around
designed specifically for exterior wood and steel stud the amount of water vapor that will move to the outside electrical boxes, wires and pipes.
applications in residential and commercial construction. wall – reducing condensation in the wall assembly.
ROCKWOOL COMFORTBATT is produced at a slight
®

Made from natural stone and recycled slag, ROCKWOOL ROCKWOOL COMFORTBATT will not absorb or retain
®

water in the event that moisture does get into the wall over-thickness to ensure a friction fit within the wall
stone wool is a high-density insulation that will fit snugly assembly. cavity. The batts will stay in place and perform equally
into wall cavities and will not slump over time. It also adds well in horizontal, sloped, dormer, vertical and overhead
When insulation material such as fiberglass gets wet, it applications.
superior acoustical performance to wall assemblies and can absorb moisture, reducing R-value, and will slump
floors and can be used in acoustic applications required by or sag within the wall cavity. This can also create the risk ROCKWOOL COMFORTBATT ’s unique flexible edge
®

building code. of mold growth in the insulation. COMFORTBATT is ® ensures the semi-rigid batts compress and expand
made from inorganic stone and does not support mold between studs and joists to eliminate slumping or
or fungus growth, even when exposed to moisture. sagging and conform to off-standard wood studs.
COMFORTBATT is also vapor permeable, meaning that
®

Higher-density batts reduce airflow within the wall cavity,


it will not absorb water but it if does get wet, it will dry
reducing convective losses. This translates into a better-
out and maintain its R-value.
performing and more comfortable thermal wall.
 Fire test performance

CAN/ULC-S702-09 Mineral Wool Thermal Type 1, Complies


Insulation for Buildings

CAN4-S114 Determination of Non-Combustible


Non-Combustibility

ASTM E 136 Determination of Non-Combustible


Non-Combustibility

CAN/ULC S102 Surface Burning Flame Spread = 0  Compliance & Specification › 2 lb/ft3 32 kg/m3
Characteristics Smoke Developed = 0
R14/15 89 mm 2.8 kg/m2
Fire-safe insulation for wall assemblies – ASTM E 84 Surface Burning Flame Spread = 0
won’t burn or develop smoke Characteristics Smoke Developed = 0 R22/23 150 mm 4.8 kg/m2

ROCKWOOL COMFORTBATT stone ®

NBC 2010, Insulation Materials Conforms R28/30 184 mm 5.9 kg/m2


wool insulation is non-combustible as Article 9.25.2.2
determined by fire tests ASTM E 136 and R32 203 mm 6.5 kg/m2
CCMC Evaluation Listing Master Format 07212: 12018-L
CAN4-S114. It will not develop smoke or promote flame Mineral Wool Batt Density ASTM C 612-00 – 32 kg/m3 (2 lb/ft3)
spread, even when directly exposed to fire, as most Insulation
other insulation materials will. CAN/ULC S102 Surface Burning Characteristics
Fire Flame Spread = 0
• Extremely high melting point of 1177°C (2150°F) Smoke Developed = 0

Moisture Resistance ASTM C 1104 Moisture Sorption 0.03%


• Does not produce smoke or toxic gases in the event The Insurance Bureau of Canada (IBC)
of a fire reference to NFPA 285: Standard Fire Test
Method for Evaluation of Fire
•  xcellent barrier against the spread of flames
E Propagation Characteristics of Exterior
2012-2013

to help protect occupants and reduce property Non-Load-Bearing Wall Assemblies Containing ROCKWOOL cuts quickly and accurately with a serrated
damage Combustible Components has led to several Studies have proven that wall assemblies with knife, such as a bread knife, so you can easily achieve
rainscreen wall system manufacturers to test with gaps and voids can result in 35% loss of the optimal fit around pipes, electrical boxes, wiring,
• Eliminates the risk of insulation accidently catching ROCKWOOL cavity wall insulation. The use of stated R-value. ROCKWOOL COMFORTBATT®’s ductwork and between studs and joists that are less than
fire during installation Spray Polyurethane Foam insulation does not allow higher-density batts make it simple for precise a standard width.
rainscreen manufacturers to meet this requirement. cutting to ensure a fit without gaps and voids.
• Excellent Passive Fire Protection – COMFORTBATT ®

can add up to an additional 15 minutes of fire


protection to wall assemblies

ROCKWOOL Group ROCKWOOL Group


2 3
Return to Residential Applications
Determining your climate zone and Specifically engineered for use in all
building code requirements. residential thermal applications.

Cathedral Ceilings

6 7 6
Attics
4

5 5

4
3

2 3
2
2
Exterior Walls
4 Zone 4 - Marine 1 Above Grade

Exposed Floors

In the northern states and Canada, chances are that standard that provides the minimum requirements for Basement Walls
building code mandates a vapor control layer be energy-efficient buildings.
installed on the warm side of the insulation. A vapor
control layer in northern climates helps to reduce This standard, or an equivalent, is applied today
the moisture diffusion through the wall assembly and in many states for commercial, government and
through to the drywall. high-rise building applications. In Canada, look to
the National Building Code and refer to section
Vapor control layers and barriers have different A-5.3.1.2 for information on condensation and energy
permeance levels measured in perms and depending conservation standards.
on your building code you may need to install a vapor
control layer with a specific perm rating. In Canada ASHRAE map of climate zones (above) Environmental Benefits That Go Beyond Residential Homes
and some northern US states, a 6 mil polyethylene Every rating agency has its own maps that divide The GREENGUARD Environmental Institute (GEI) is a non-profit organization that oversees the
®

sheet is commonly used, but always check with your regions into thermal or climate zones to tailor codes GREENGUARD Gold standards. The GEI’s mission is to protect human health and quality of life
local building code for guidance. and standards to what is appropriate for that particular through programs that improve indoor air that people breathe. GREENGUARD Gold Certification
region. (formerly known as GREENGUARD Children & Schools Certification) offers stricter certification
ASHRAE – history of R-value requirements criteria, considering safety factors to account for sensitive individuals (such as children and the
The American Society of Heating, Refrigerating and Air In Zone 1, Zone 2, Zone 3 and Zone 4 (except Zone 4 elderly), and ensures that a product is acceptable for use in environments such as schools and
Conditioning Engineers (ASHRAE) is an international Marine), no vapor retarder is required on the interior healthcare facilities. ROCKWOOL COMFORTBATT products are certified to this standard and are
®

society of technical individuals who provide knowledge surface of insulated wall and floor assemblies while recognized by the United States Green Building Council’s (USGBC) LEED program.
®

to the building industry on heating, ventilation, air in the northern states, some form of vapor retarder is
conditioning, and refrigeration (HVAC&R). The Society likely code mandatory.
developed ASHRAE 90.1, an energy conservation

ROCKWOOL Group ROCKWOOL Group


4 5
Return to Residential Applications
Ideal applications for COMFORTBATT insulation. ®

The higher density of ROCKWOOL COMFORTBATT ensures a


A range of COMFORTBATT products to
®
®

snug friction fit in the wall cavity. Note: A vapor retarder may be
required in the wall assembly, depending on the geographical
location of the building.
7 suit all your building requirements.
The COMFORTBATT Residential Wall Assembly
®
5 4
Coverage
Available Available Stud/Joist
(shown from outside to inside) R-Value RSI Value Thickness Width Length Sq. Ft.
6 in Canada in US Type
➊ Cladding 2 (per bag)
➋ Air Barrier 3 Wood Stud
➌ Sheathing
➍ 2” x 6” Wood Studs R14 4 7 2.47 Wood 3.5” 15.25” 47” 59.7
1
➎ 5.5” COMFORTBATT ®

➏ Vapor Retarder* R14 4 7 2.47 Wood 3.5” 23” 47” 60.1

➐ Gypsum
R15 7 4 2.64 Wood 3.5” 15.25” 47” 59.7

R15 7 4 2.64 Wood 3.5” 23” 47” 60.1

R22 4 7 3.87 Wood 5.5” 15.25” 47” 39.8

In addition to residential applications, ROCKWOOL COMFORTBATT ®


9
R22 4 7 3.87 Wood 5.5” 23” 47” 37.5

is ideal as a component of the BEDR cavity wall system.


R23 7 4 4.05 Wood 5.5” 15.25” 47” 39.8

BEDR Wall Components


R23 7 4 4.05 Wood 5.5” 23” 47” 37.5
(shown from outside to inside) 7 8

➊ Terra Cotta Cladding R24 4 7 3.87 Wood 5.5” 15” 47” 29.4
➋ 1” Air Space (1/2” minimum)
➌1  ”-2” CAVITYROCK® MD Insulation (R4.2–R8.4) R24 4 7 3.87 Wood 5.5” 22.75” 47” 29.7
6
or 2.5”–5” CAVITYROCK® DD (R10.75–R21.5)
➍ Permeable Air Barrier 5 R28 4 7 4.92 Wood 7.25” 15.25” 47” 29.9

➎ Exterior Gypsum Board 3


4
R28 4 7 4.92 Wood 7.25” 23” 47” 30.7
➏ 3.5” or 6” Steel Stud
➐ 3.5” or 6” COMFORTBATT® Insulation 1 R30 7 4 5.28 Wood 7.25” 15.25” 47” 29.9
➑ Vapor Barrier* 2

➒ 5/8” Gypsum Board R30 7 4 5.28 Wood 7.25” 23” 47” 30.7

R32 4 7 5.64 Wood 8” 15.25” 47” 29.9

R32 4 7 5.64 Wood 8” 23” 47” 30.0

Steel Stud

When insulating attics, use two layers of COMFORTBATT to achieve


®

R10 4 4 1.76 Steel 2.5” 16.25” 48” 86.7


the required R-value. The bottom layer should run parallel to the
joists and the top layer run in the opposite direction. For attics and 1 2 R14 4 7 2.47 Steel 3.5” 16.25” 48” 65.0
cathedral ceilings, only a single layer of COMFORTBATT is required
®

3 R14 4 7 2.47 Steel 3.5” 24.25” 48” 64.7


between the roof trusses. 5
4

The COMFORTBATT Roof/Attic Assembly


® R15 7 4 2.64 Steel 3.5” 16.25” 48” 65

(shown from outside to inside) R15 7 4 2.64 Steel 3.5” 24.25” 48” 64.7
➊ Shingles
➋ Tar Paper R22.5 4 4 3.96 Steel 6.0” 16.25” 48” 43.3
➌ Sheathing 4

➍ 2” x 10” Roof Trusses R22.5 4 4 3.96 Steel 6.0” 24.25” 48” 40.4

➎ COMFORTBATT® (R30/R32)
R24 4 4 4.22 Steel 6.0” 16.25” 48” 43.3
➏ Ceiling Joists 7
➐ COMFORTBATT® (R22/R23 or R28/R30) R24 4 4 4.22 Steel 6.0” 24.25” 48” 40.4
two layers running perpendicular 6

*Check with your local building code for approved vapor barrier/retarder information.

ROCKWOOL Group ROCKWOOL Group


6 7
Return to Residential Applications
At the ROCKWOOL Group, we are
committed to enriching the lives of
everyone who comes into contact
with our solutions. Our expertise
is perfectly suited to tackle many of
today’s biggest sustainability and
development challenges, from energy
consumption and noise pollution
to fire resilience, water scarcity and
flooding. Our range of products
reflects the diversity of the world’s
needs, while supporting our
stakeholders in reducing their own
carbon footprint.

Stone wool is a versatile material and


forms the basis of all our businesses.
With approx. 10,500 passionate
colleagues in 38 countries, we are
the world leader in stone wool
solutions, from building insulation to
acoustic ceilings, external cladding
systems to horticultural solutions,
engineered fibres for industrial use
to insulation for the process industry
and marine & offshore.

AFB , CAVITYROCK ,
® ®

COMFORTBATT , CONROCK ,
® ®

CURTAINROCK , ROCKBOARD ,
® ®

TOPROCK , MONOBOARD , ROXUL


® ® ®

are registered trademarks of the


ROCKWOOL Group in USA
and ROXUL Inc. in Canada.

ROCKWOOL , COMFORTBOARD ,
™ ™

FABROCK , ROXUL SAFE ,


™ ™

ROCKWOOL PLUS , and AFB evo


™ ™

are trademarks of the ROCKWOOL


Group in USA and ROXUL Inc. in
Canada.

SAFE’n’SOUND is a registered
®

trademark used under license by


Masonite Inc. Publication date - edition: 12/2017

ROCKWOOL
8024 Esquesing Line
Milton, ON L9T 6W3
Tel: 1 800 265 6878
rockwool.com
Return to Residential Applications
COMFORTBATT Technical Data Sheet
®

COMFORTBATT
Batt Insulation 07210*
® Thermal Batt Insulation Blanket Insulation 07 21 16**

Thermal Batt Insulation ROCKWOOL COMFORTBATT® is a mineral wool batt insulation designed for thermal resistance in wood and steel framing.

Performance Test Standard

Compliance Mineral Fibre Thermal Insulation for Buildings, Type 1 Compliant CAN/ULC S702

Flame spread index = 0; Smoke developed index = 0 CAN/ULC S102


Reaction to Fire
Determination of Non-combustibility of Building Materials - Non-combustible CAN/ULC S114

Density > 2 lbs/ft³ (>32 kg/m³) ASTM C167

Wood Stud Steel Stud ASTM C518

R14 (RSI 2.47) - 3.5" thick (89 mm) R10 (RSI 1.76) - 2.5" thick (64 mm)

R22 (RSI 3.87) - 5.5" thick (140 mm) R14 (RSI 2.47) - 3.5" thick (89 mm)
Thermal Resistance
R24 (RSI 4.23) - 5.5" thick (140 mm) R22.5 (RSI 3.96) - 6" thick (152 mm)

R28 (RSI 4.93) - 7.25" thick (184 mm) R24 (RSI 4.23) - 6" thick (152 mm)

R32 (RSI 5.64) - 8" thick (203 mm)

Wood Stud 16” (406 mm) on centre: 15.25” x 47” (387 mm x1194 mm)

Wood Stud 24” (610 mm) on centre: 23” x 47” (584 mm x 1194 mm)
Dimensions
Steel Stud 16” (406 mm) on centre: 16.25” x 48” (413 mm x 1219 mm)

Steel Stud 24” (610 mm) on centre: 24.25” x 48” (616 mm x 1219 mm)

Easy Fit
Easily cut to achieve an optimal fit around pipes,
ROCKWOOL COMFORTBATT® is a semi-rigid stone electrical wiring boxes, ductwork and between Issued 01-01-18 NOTE: *Master Format 1995 Edition **Master Format 2004 Edition. As ROCKWOOL has no control over installation design and
wool batt insulation for exterior wood and steel stud studs and joists that are less than standard width. Supersedes 08-23-17 workmanship, accessory materials or application conditions, ROCKWOOL does not warranty the performance or results of any
installation containing ROCKWOOL’s products. ROCKWOOL’s overall liability and the remedies available are limited by the general
applications in both new construction and renovations. terms and conditions of sale. This warranty is in lieu of all other warranties and conditions expressed or implied, including the warranties
of merchantability and fitness for a particular purpose.
It features a unique flexible edge designed to compress
as the batt is inserted then spring back, expanding the
batt against the frame studs to give a complete fill. This
flexibility ensures the expected R-value is achieved and
maintained.

Non-combustible and fire resistant, COMFORTBATT® will


not develop toxic smoke or promote flame spread, even
when exposed directly to a fire. It also offers water and
moisture resistance and excellent sound absorbency.

COMFORTBATT® is an effective way to improve a home’s


energy efficiency. It is GREENGUARD Gold Certified and
contributes to a healthier indoor environment.

Learn more at rockwool.com

8024 Esquesing Line, Milton, ON L9T 6W3


Tel: 800-265-6878 • Fax: 800-991-0110
rockwool.com
ROCKWOOL Group
9
Return to Residential Applications
FIRE & SOUNDPROOFING INSULATION

SAFE’N’SOUND
®

Fire and Soundproofing Insulation


for Interior Partition Walls and Floors.

Return to Residential Applications


Fire resistance enhances home safety Higher density means a better fit
• Combination of natural stone and recycled content • ROCKWOOL SAFE’n’SOUND Batts are simple to cut
®

makes ROCKWOOL insulation an excellent fire barrier with a serrated knife (such as a bread knife)

•  oes not develop smoke or promote flame spread,


D •  lean, straight cuts provide optimal fit around
C
even when directly exposed to fire electrical boxes, wiring, and pipes – minimizing air flow

•  an withstand temperatures up to 1177°C (2150°F)


C •  uperior friction fit between studs completely fills the
S
providing occupants valuable extra time in case of a fire wall cavity preventing insulation from sagging – unlike
Sound control and fire safety competitors’ products

from one batt Insulation.


ROCKWOOL SAFE’n’SOUND is a batt insulation
®
Water repellent & won’t sustain mold
designed specifically for interior wall and floor/ceiling • ROCKWOOL SAFE’n’SOUND is resistant to water,
®

applications. This stone wool insulation is made from rot, mold, mildew and bacterial growth
natural stone and recycled content. It’s a green product
that provides superior sound absorbency and fire • 
Contributes to a safer and healthier indoor
protection for overall comfort and safety. environment

Because SAFE’n’SOUND is designed for interior


® • GREENGUARD certified, receiving the highest
®

applications, it has not been engineered as a thermal designation for indoor air quality
insulation but as a fire barrier and for soundproofing.
Stone wool in general has excellent fire ratings, does not
burn and can add valuable time for evacuation in the
event that a fire occurs. Its higher density properties
also make it an ideal solution for minimizing sound
traveling between rooms.

ROCKWOOL SAFE’n’SOUND® is an excellent


acoustic barrier that effectively absorbs
sound, making it the choice of professional
recording studios.

ROCKWOOL Group ROCKWOOL Group


2 3
Return to Residential Applications
Typical Assemblies for
Bathrooms Bedrooms
ROCKWOOL SAFE’n’SOUND . ®

Side View

Top View

Home Offices Entertainment Rooms Laundry/Utility Rooms

Single stud interior wall Interior ceiling/floor


(Wood Studs – 16” On Center) (2 x 10 Joists – 16” On Center)

Using ROCKWOOL SAFE’n’SOUND , ®


Using ROCKWOOL SAFE’n’SOUND , ®

5/8” drywall (type x) and resilient 5/8” drywall (type x) and resilient
channels at 16” provides: channels at 24” provides:

• Fire Rating: 1 hour • Fire Rating: 30 minutes

• Sound Transmission Class (STC): 45 • Sound Transmission Class (STC): 50

SAFE’n’SOUND ®
SAFE’n’SOUND ®

Wall Components Ceiling/Floor Components


Sound control delivers peace and quiet
(shown from outside to inside) (shown from top to bottom)
1. 5/8” Type X Gypsum 1. Plywood Floor • Install SAFE’n’SOUND in interior walls between
®
• Provides higher sound absorption against low-
rooms and in ceilings between floors frequency (bass) ranges, which are most difficult to
2. 3” SAFE‘n’SOUND ®
2. Air Space block
• Higher-density batts more effectively reduce
3. Resilient Channel 3. Two layers of SAFE’n’SOUND ®
airflow – thereby decreasing sound transmission • Typical household applications include home theater,
basements (ceilings), home office, laundry room,
4. 5/8” Type X Gypsum Board 4. Resilient Channel bathroom and furnace room
5. Gypsum Board

The SAFE‘n’SOUND® interior partition


Because it doesn’t burn, SAFE‘n’SOUND®
wall and floor system is ideal for
can delay the spread of fire for added safety.
residential renovation activity such as
media rooms.

ROCKWOOL Group ROCKWOOL Group


4 5
Return to Residential Applications
Specify ROCKWOOL SAFE’n’SOUND ® Compliance and performance

for every home.


System Description Sound Transmission Class (STC) Fire Resistance

5/8” gypsum boards


3 5/8” steel studs spaced
52 1 Hour
24” centers
ROCKWOOL SAFE‘n’SOUND®

Home life has changed, and sound dampening Satisfy your customers by creating Above results are based upon testing using Type X gypsum board.
is more important than ever a quieter home For additional designs, please contact ROCKWOOL Technical Services.

Life is getting louder around the home. Televisions, home Don’t wait for your home buyers to ask about
theaters, computers and video games blare from almost ways to make their homes quieter, safer and
Acoustical performance
every room. Family cell phones constantly ring. More more comfortable. Make peace and quiet and
people work from home offices and entertainment rooms fire protection available on every new build ASTM C423
are the norm. with ROCKWOOL SAFE‘n’SOUND . ®

CO-EFFICIENTS AT FREQUENCIES

More and more, sound dampening is a must-have Unlike other insulation, ROCKWOOL SAFE‘n’SOUND ®

System Description Thickness 125 Hz 250 Hz 500 Hz 1000 Hz 2000 Hz 4000 Hz NRC
requirement for any modern family home. And, it’s an ideal provides higher sound absorption against low-frequency
revenue-generating opportunity to offer ROCKWOOL (bass) ranges. ROCKWOOL
3” 0.52 0.96 1.18 1.07 1.05 1.05 1.05
SAFE’n’SOUND – the premium acoustic insulation for
®
SAFE’n’SOUND®

interior walls and for ceilings between floors.


Compliance and performance

CAN/ULC-S702-09 Mineral Fiber Thermal Insulation for Buildings Type 1, Complies

ASTM C 665 Mineral Fiber Blanket Thermal Insulation Type 1, Complies

CAN4-S114 Determination of Non-Combustibility Non-Combustible

ASTM E 136 Surface Burning Characteristics Non-Combustible

Flame Spread = 0
CAN/ULC S102 Surface Burning Characteristics
Smoke Developed = 0

Flame Spread = 0
ASTM E 84 (UL 723) Surface Burning Characteristics
Smoke Developed = 0
ROCKWOOL SAFE’n’SOUND ®

& GREENGUARD Gold ® CAN/ULC S102 Smolder Resistance 0.09%

The GREENGUARD Environmental Institute


(GEI) is a non-profit organization that oversees
the GREENGUARD Gold standards. The GEI’s
Dimensions
mission is to protect human health and quality of
life through programs that improve indoor air Steel Stud Wood Stud
that people breathe. Greenguard Gold
Certification (formerly known as Greenguard 3” x 16.25” x 48” 3” x 15.25” x 47”
Children & Schools Certification) offers stricter 76 mm x 413 mm x 1219 mm 76 mm x 387 mm x 1194 mm

certification criteria, considering safety factors


With flexible edges With flexible edges ROCKWOOL leads the way with
to account for sensitive individuals (such as 3” x 24.25” x 48” 3” x 23” x 47” sustainable, eco-friendly products
children and the elderly), and ensures that a 76 mm x 616 mm x 1219 mm
With flexible edges
76 mm x 584 mm x 1194 mm
With flexible edges
in the building industry and contains
product is acceptable for use in environments natural, inorganic materials made with
such as schools and healthcare facilities. recycled content.
ROCKWOOL SAFE’n’SOUND® products are Density
certified to this standard and are recognized by
the United States Green Building Council’s 2.5 lbs/ft3 40 kg/m3
(USGBC) LEED® program.

ROCKWOOL Group ROCKWOOL Group


6 7
Return to Residential Applications
At the ROCKWOOL Group, we are
committed to enriching the lives of
everyone who comes into contact
with our solutions. Our expertise
is perfectly suited to tackle many of
today’s biggest sustainability and
development challenges, from energy
consumption and noise pollution
to fire resilience, water scarcity and
flooding. Our range of products
reflects the diversity of the world’s
needs, while supporting our
stakeholders in reducing their own
carbon footprint.

Stone wool is a versatile material and


forms the basis of all our businesses.
With more than 11,000 employees
in 39 countries, we are the world
leader in stone wool solutions,
from building insulation to acoustic
ceilings, external cladding systems
to horticultural solutions, engineered
fibres for industrial use to insulation
for the process industry and marine
and offshore.

AFB , CAVITYROCK ,
® ®

COMFORTBATT , CONROCK ,® ®

CURTAINROCK , ROCKBOARD ,
® ®

TOPROCK , MONOBOARD , ROXUL


® ® ®

are registered trademarks of the


ROCKWOOL Group in USA and
ROXUL Inc. in Canada.

ROCKWOOL , COMFORTBOARD ,
™ ™

FABROCK , ROXUL SAFE ,


™ ™

ROCKWOOL PLUS , and AFB evo™ ™

are trademarks of the ROCKWOOL


Group in USA and ROXUL Inc. in
Canada.

SAFE’n’SOUND is a registered
®

Publication date - edition: 01/2018


trademark used under license by
Masonite Inc.

ROCKWOOL
8024 Esquesing Line
Milton, ON L9T 6W3
Tel: 1 800 265 6878
rockwool.com
Return to Residential Applications
SAFE’N’SOUND Technical Data Sheet
®

SAFE’N’SOUND
Batt Insulation 07210 & 09820*
® Residential Fire and Soundproofing Insulation Acoustic Blanket Insulation 09 81 16**

Fire and Soundproofing Insulation ROCKWOOL SAFE’n’SOUND® is a mineral wool batt insulation for interior partitions of wood and steel frame
construction where superior fire resistance and acoustical performance is required.

Performance Test Standard

Mineral Fiber Blanket Thermal Insulation, Type 1 Compliant ASTM C665


Compliance
Mineral Fiber Thermal Insulation for Buildings, Type 1 Compliant CAN/ULC S702

Flame spread index = 0; Smoke developed index = 0 ASTM E84 (UL 723)

Flame spread index = 0; Smoke developed index = 0 CAN/ULC S102

Reaction to Fire Determination of Non-combustibility of Building Materials - Non-combustible CAN/ULC S114

Behavior of materials at 750°C - Non-combustible ASTM E136

Smolder Resistance - 0.09% CAN/ULC S129

Density Actual Density - 2.5 lb/ft³ (40 kg/m³) ASTM C167

Thickness Product is available in 3” thickness (76.2 mm)


Dimensions Wood Stud 16” (406 mm) on center: 15.25” x 47” (387 mm x 1194 mm)
Wood Stud 24” (610 mm) on center: 23” x 47” (584 mm x 1194 mm)
Steel Stud 16” (406 mm) on center: 16.25” x 48” (413 mm x 1219 mm)
Steel Stud 24” (610 mm) on center: 24.25” x 48” (616 mm x 1219 mm)

System Description Sound Transmission Fire Resistance


Class (STC)

5/8" gypsum boards (type x) 52 1 hour


3 5/8” steel studs spaced 24” OC
SAFE’n’SOUND® Steel Stud

5/8" gypsum boards (type x) 45 1 hour (non-loadbearing)


System Testing
2x4” wood studs spaced 16” OC 45 min (loadbearing)
A Quiet Space SAFE’n’SOUND® Wood Stud
Resilient Channels spaced 16” OC
A high density and unique fiber structure absorbs
ROCKWOOL SAFE‘n’SOUND® is a stone wool insulation sound and reduces noise traveling from one 2x10" Wood Joists spaced 16" OC 50 30 minutes
for use in interior partitions of residential wood and steel 2 layers SAFE’n’SOUND® Wood Stud
room to another, improving occupant comfort. Resilient Channels spaced 24” OC
stud construction where superior fire resistance and
5/8” gypsum boards (type x)
acoustical performance are required.
Thickness 125 Hz 250 Hz 500 Hz 1000 Hz 2000Hz 4000 Hz NRC ASTM C423
Withstanding temperatures up to 2150°F (1177°C), Acoustical Performance
SAFE‘n’SOUND® is non-combustible and will not produce 3” 0.52 0.96 1.18 1.07 1.05 1.05 1.05
toxic smoke or promote flames spreading, even when
directly exposed to fire. This adds valuable extra time
for people to reach safety and for fire services personnel
to arrive.

SAFE‘n’SOUND® has excellent acoustical dampening


properties and provides an easy friction fit into walls, Issued 01-01-18 NOTE: *Master Format 1995 Edition **Master Format 2004 Edition. As ROCKWOOL has no control over installation design and
ceiling and floor applications. It is GREENGUARD Supersedes 08-23-17 workmanship, accessory materials or application conditions, ROCKWOOL does not warranty the performance or results of any
installation containing ROCKWOOL’s products. ROCKWOOL’s overall liability and the remedies available are limited by the general
Gold Certified and contributes to a healthier terms and conditions of sale. This warranty is in lieu of all other warranties and conditions expressed or implied, including the warranties
indoor environment. of merchantability and fitness for a particular purpose.

Learn more at rockwool.com

8024 Esquesing Line, Milton, ON L9T 6W3


Tel: 800-265-6878 • Fax: 800-991-0110
rockwool.com
Return to Residential Applications
ROXUL SAFE™ 45 Technical Data Sheet

ROXUL SAFE 45
Board Insulation 07210*
™ Residential Party Wall Insulation Board Insulation 07 21 13**

Residential Party Wall Insulation ROXUL SAFE™ 45 is a semi-rigid, mineral wool insulation board designed for firestopping in concealed spaces
of residential units. This product complies with the 2010 National Building Code 9.10.16.3(2).

Performance Test Standard

Mineral Fiber Block and Board Thermal Insulation - Type IVA Compliant ASTM C612
Compliance
Mineral Fiber Thermal Insulation for Buildings - Type 1 Compliant CAN/ULC S702

Flame spread index = 0; Smoke developed index = 0 ASTM E84 (UL 723)
Flame spread index = 0; Smoke developed index = 0 CAN/ULC S102
Reaction to Fire
Determination of Non-combustibility of Building Materials - Non-combustible CAN/ULC S114
Behavior of materials at 750°C - Non-combustible ASTM E136

Density Actual Density - 4.4 lbs/ft³ (70 kg/m³) ASTM C303

Dimensional Stability Linear Shrinkage - <1% @ 1200°F ASTM C356

Stress Corrosion Cracking Tendency of Austenitic Stainless Steel - Passed ASTM C795
Corrosion Resistance
Corrosion of Steel - Passed ASTM C665

R-Value / inch @ 75oF 4.2 hr.ft2.F/Btu ASTM C518 (C177)


Thermal Resistance RSI value / 25.4 mm @ 24oC 0.74 m2K/W

Moisture Sorption by weight - 0.03% ASTM C1104


Reaction to Moisture
Determination of Fungi Resistance - Passed ASTM C1338

Thickness Product is available in 1” thickness (25.4 mm)


Dimensions 16” x 48” (406 mm x 1219 mm), 24” x 48” (610 mm x 1219 mm)

Issued 01-01-18 NOTE: *Master Format 1995 Edition **Master Format 2004 Edition. As ROCKWOOL has no control over installation design and
Supersedes 08-23-17 workmanship, accessory materials or application conditions, ROCKWOOL does not warranty the performance or results of any
installation containing ROCKWOOL’s products. ROCKWOOL’s overall liability and the remedies available are limited by the general
Party Wall System Advantage terms and conditions of sale. This warranty is in lieu of all other warranties and conditions expressed or implied, including the warranties
of merchantability and fitness for a particular purpose.
Reduces time, labor and material costs
ROXUL SAFE™ 45 is a semi-rigid stone wool insulation on party wall stud partitions and increases
board from ROCKWOOL that is specifically engineered as occupant comfort.
a fire-blocking material for concealed spaces of
multi-unit residential buildings.

Using ROXUL SAFE™ 45 with our ROCKWOOL batt 3.5” ROCKWOOL


Batt insulation
insulation creates a high-density “party” wall system
that improves sound dampening and fire performance.
It also reduces the time, labor and material costs usually
associated with adding a double layer of gypsum over 1" air space
the wall studs. 5/8"gypsum

With this party wall system in place, required performance Double wood studs
(2"x4" / 16" OC)

specs exceed code while vibration and sound transmission


between party walls is reduced.

ROXUL SAFE™ 45 fire separation board complies with the


fire-blocking National Building Code, is easy to install, ROCKWOOL
ROXUL SAFE® 45 (Fire Stop)
Batt insulation
and offers excellent water and moisture resistance.

Learn more at rockwool.com

8024 Esquesing Line, Milton, ON L9T 6W3


Tel: 800-265-6878 • Fax: 800-991-0110
rockwool.com
Return to Residential Applications
COMFORTBOARD™ 80 Technical Data Sheet

COMFORTBOARD™ 80
Board Insulation 07210*
Continuous Insulation Board Insulation 07 21 13**

Continuous Insulation ROCKWOOL COMFORTBOARD™ 80 is a rigid mineral wool, non-structural insulated sheathing board used
as continuous insulation in high-performance wall systems.

Performance Test Standard

Mineral Fiber Block and Board Thermal Insulation - Type IVB Compliant ASTM C612
Compliance
Mineral Fiber Thermal Insulation for Buildings - Type 1 Compliant CAN/ULC S702

Flame spread index = 0; Smoke developed index = 0 ASTM E84 (UL 723)
Reaction to Fire Flame spread index = 0; Smoke developed index = 0 CAN/ULC S102
Determination of Non-combustibility of Building Materials - Non-combustible CAN/ULC S114

Density Actual Density - 8 lbs/ft³ (128 kg/m³) ASTM C303

Stress Corrosion Cracking Tendency of Austenitic Stainless Steel - Passed ASTM C795
Corrosion Resistance
Corrosion of Steel - Passed ASTM C665

R-Value / inch @ 75oF 4 hr.ft2.F/Btu


Thermal Resistance RSI value / 25.4 mm @ 24oC 0.70 m2K/W ASTM C518 (C177)

Moisture Sorption - 0.05% ASTM C1104


Reaction to Moisture Water Vapor Transmission, Desiccant Method - 1768ng/Pa.s.m2 (31 perm) ASTM E96
Determination of Fungi Resistance - Passed ASTM C1338

439psf (21kPa) @ 10% compression ASTM C165


Compressive Strength
1065psf (50kPa) @ 25% compression

Thickness 1.25” (31.8 mm), 1.5” (38.1 mm), 2” (50.8 mm), 2.5” (63.5 mm), 3” (76.2 mm)
Dimensions 24” x 48” (610 x 1219 mm), 36” x 48” (914 x 1219 mm),
48” x 72”(1219 x 1829 mm), 48” x 96” (1219 x 2438 mm)

Thickness 125 Hz 250 Hz 500 Hz 1000 Hz 2000Hz 4000 Hz NRC ASTM C423

1.5” 0.21 0.64 0.92 1 0.95 1.01 0.9


Acoustical Performance
2” 0.43 0.78 0.9 0.97 0.97 1 0.9
Reduce Thermal Bridging 3” 0.75 0.82 0.89 0.94 1 1 0.9
COMFORTBOARD™ 80 helps reduce thermal
ROCKWOOL COMFORTBOARD™ 80 is a rigid stone wool bridging through wood framing, leading to SM

continuous insulation board used as a non-structural sheathing


ROCKWOOL™ Exterior Stone Wool

a higher-performing building envelope.


Insulation-Unfaced: CAVITYROCK®,
CURTAINROCK® 40/80,

Please contact ROCKWOOL for


COMFORTBOARD™ 110/80, ROXUL
SAFE™
ROCKWOOL

product in residential construction.


Final Assembly: Byhalia, MS, USA

Declare labels for other ROCKWOOL


Life Expectancy: Life of Structure
End of Life Options: Salvageable/Reusable in its En-

Ingredients:

Mineral Wool; Urea, Polymer with Formaldehyde

manufacturing facilities.
and Phenol1; Syrups, Hydrolized Starch;
Proprietary Ingredient (0.05-0.2%)2

It is designed to provide increased thermal performance


LBC Temp Exception I10-E9 Phenol Formaldehyde in Mineral
1

Wool Insulation
2
LBC Temp Exception I10-E4 Proprietary Ingredients <1%

3773
Living Building Challenge Criteria:

RXL-0002 EXP. 01 AUG 2019

to the building envelope. Installing COMFORTBOARD™ 80


VOC Content: N/A VOC Emissions: N/A
Declaration Status LBC Red List Free
LBC Compliant
Declared
MANUFACTURER RESPONSIBLE FOR LABEL ACCURACY
INTERNATIONAL LIVING FUTURE INSTITUTE SM
declareproducts.com

as continuous insulation with our ROCKWOOL


COMFORTBATT® as the wall cavity insulation Issued 01-01-18 NOTE: *Master Format 1995 Edition **Master Format 2004 Edition. As ROCKWOOL has no control over installation design and
Supersedes 08-23-17 workmanship, accessory materials or application conditions, ROCKWOOL does not warranty the performance or results of any
contributes to a higher effective R-value wall system. installation containing ROCKWOOL’s products. ROCKWOOL’s overall liability and the remedies available are limited by the general
terms and conditions of sale. This warranty is in lieu of all other warranties and conditions expressed or implied, including the warranties
COMFORTBOARD™ 80 is non-combustible, vapor permeable, of merchantability and fitness for a particular purpose.
water repellent and sound absorbent.
It has also received ICC-ES validated product acceptance in
accordance to IRC and IBC for the following uses:
• non-structural thermal insulation in non-fire-resistive rated
dwellings
• exterior perimeter insulation around foundation
• under flat concrete slab
• a component of residential wood-framed cathedral ceilings
• and in areas where probability of termite infestation is
‘very heavy.’

Learn more at rockwool.com

8024 Esquesing Line, Milton, ON L9T 6W3


Tel: 800-265-6878 • Fax: 800-991-0110
rockwool.com
Return to Residential Applications
Roofing
Applications
Low Slope
Roofing Brochure

TOPROCK DD®

Flat Roof Technical Data Sheet

TOPROCK DD PLUS
®

Bitumen-coated Flat Roof Technical Data Sheet

MULTIFIX ™

Flat Roof Technical Data Sheet

Click on any of the above brochures or data


sheets to be directed to that specific document.

Visit www.rockwool.com for our full


Product Documentation Library.
ENRICHING MODERN LIVING

Low Slope Roofing


Improving Value with Stone Wool Roof Systems

ROCKWOOL Group
16
Return to Roofing Applications
The Value in Stone Wool Roofing Insulation ROCKWOOL MULTIFIX ™

Our stone wool roof boards provide increased value to Thermal resistance of stone wool increases at colder ROCKWOOL MULTIFIX™ is a dual-density, rigid roofing insulation faced with a
low-slope roofing projects due to the inherent benefits temperatures and does not decrease over time, allowing
offered by stone wool insulation. By utilizing a layer of for more predictable, longer-lasting energy performance high-performance mineral coated glass fiber layer.
stone wool above the rest of the thermal insulation in a that provides increased ROI. Read more pg. 7
hybrid system, the stone wool provides added resilience ROCKWOOL MULTIFIX has all the product qualities of

and energy efficiency to improve the overall system. The Why it matters: our TOPROCK DD product:
®

positive effects of the hybrid solution can begin with as More predictable energy performance allows for properly
little as 2” of stone wool insulation added and based on designed mechanical equipment and longer-lasting • Insulation and coverboard in one
energy modeling can be incremental up to 50% of the performance means saving money.
• Suitable for new building, re-roofing and re-covering
required R-value before showing decreasing effects in
TOPROCK DD has a high-density upper layer and a
®
applications
performance benefits.
lower-density bottom layer. The high-density upper layer
allows for increased compressive strength while the lower- • Fire, impact and hail resistant
This layer acts as a thermal buffer between the extreme
density bottom layer allows for loads to be shared across The glass fiber coating allows the product to be used with
temperature of the exterior and the thermal insulation,
the entire board. Read more pg. 10 a number of different bonding methods for conventional
as well as providing added mass for acoustics, increased
dimensional stability, fire resistance and impact resistance Why it matters: roofing systems.
that can lengthen the life of the roof assembly. Point load resistance is key on flat roofs during
construction and maintenance work where occasional
foot traffic impacts the boards. The TOPROCK DD ®

boards also return to their original state once the load is


removed. Bonding Method TOPROCK® DD TOPROCK® DD Plus ROCKWOOL MULTIFIX™

Mechanically Fastened • •
Made from basalt rock and steel slag, stone wool
Torch Applied Membranes • •
products are naturally fire resistant, meet the FM 4470
NCC rating requirements and have 0/0 flame and smoke Hot Mopped Membranes • •
spread ratings. Read more pg. 10 Some applications,
Cold Applied Membranes •
consult ROCKWOOL
Why it matters:
Self-Adhered/Peel and Stick Membranes •
Increased fire resistance reduces the risk of a fire event
causing damages, loss of business or increased insurance
costs. Toxic smoke can cause additional environmental
and health concerns.
Better Adhesion, Better Performance
Non-directional fiber structure and increased mass lead ROCKWOOL MULTIFIX has been tested for compliance

to improved acoustic performance over traditional foam with a number of membrane systems in order to prove
plastic insulations. Read more pg. 9 the performance of this mineral-coated product.
Why it matters: ROCKWOOL MULTIFIX has received approval from

When used in combination with other mass layers, such a number of membrane manufacturers for use in their
as gypsum, high sound reduction can be achieved, critical systems. Better adhesion between the insulation or
for areas subject to increased noise pollution. coverboard and membrane can improve performance
in high-wind areas and reduce potential for leaks and
Lower co-efficient of expansion means increased moisture in a system.
dimensional stability over temperature changes and less
gapping between boards. Read more pg. 8

Why it matters:
Over time, gaps between other insulation products
become large and decrease effective thermal resistance.

Return to Roofing Applications


Building Better With Building Science
Roofing Products
Building science research is continuously being
TOPROCK DD ®
conducted to improve the performance of the buildings
Thermal Roofing Insulation and in order to achieve more effective performance in
Coverboard the building enclosure. The performance of the roof
Building Science
enclosure can have a significant effect on the overall
TOPROCK DD is a dual-density
®
building, especially on large one-story buildings.
rigid stone wool roof board available
unfaced or with facing for improved Building science research allows for increased building
adhesion. TOPROCK DD Plus has
®
modeling to better reflect the performance of the
a bitumen coating for hot adhered building once it is in use. For walls, research has shown R-Value Calculations
systems. ROCKWOOL MULTIFIX has ™
that the nominal R-value of the insulation is not what you
a mineral coated fiber glass facer that should expect due to the effects of thermal drift, thermal
is approved for use with hot and cold bridging and other factors, and exterior walls have begun
adhered systems. to move to an “effective R-value” for the wall rather than
nominal. For low-slope roofs, energy codes still rely on Thermal Bridging Modeling
• Insulation and coverboard in one nominal R-values; however, better performance can be
achieved by looking at the effective performance of the
• Suitable for new building,
roof system.
re-roofing and re-covering
applications More than Just R-value
Hygrothermal Modeling
Modeling the system components together allows
• Also used in tapered systems for
additional factors to be considered in the performance
positive drainage
of the roof system such as temperature changes, thermal
• Standard thicknesses: 2 – 6", .5" drift, thermal bridging and gaps occurring.
increments
While it never guarantees results, it can allow the owner Full Building Modeling
• R-value of 3.8 per inch as tested to better understand the expected performance of their
at 75ºF per ASTM C518 standard building and not experience sticker shock once the
energy bills start to add up.

ROCKWOOL BUILDING SCIENCE (RBS)


We offer building science resources for architects,
designers, specifiers, consultants and owners who are
looking for information on how to efficiently design or
improve their building enclosure systems, including their
low-slope roof systems. These knowledgeable building
science specialists can review building assemblies and
provide quantitative feedback and recommendations that
can be implemented into your project.

RBS Team work is completed on an individual project


basis and will include good, better and best
recommendations that can provide assistance to make
informed, educated decisions to increase
the overall performance of the building.

TOPROCK® DD products are available with


two different facing options: bitumen or
mineralcoated fiberglass. The bitumen-coated
TOPROCK® DD Plus products are used in hot
adhered applications such as torch or hot-
mopped asphalt. The mineral-coated fiberglass
facing used on ROCKWOOL MULTIFIX™ can be
used with both hot and cold adhesives.

Return to Roofing Applications


Our Solutions
Thermal Insulation
Hybrid Insulation System
A hybrid insulation system utilizes the benefits of two
In the system shown before, the polyiso is subjected to
a 40°F temperature average and a 10°F temperature at
That Won't Degrade
different insulating materials to achieve increased the top of the layer. Increasing the thickness of the stone
performance. Polyisocyanurate insulation is the most wool increases both the average temperature and the Thermal Resistance Across Temperatures Effects of Aging
widely used insulation in the low-slope roofing industry due temperature at the face of the polyiso layer. The ASTM C518 (C177) standard is conducted at mean In a third party in-situ test conducted by RDH Building
to its high published R-value per inch and its lightweight temperatures of 25°F (-4°C), 40°F (4°C) , 75°F (24°C) Science, polyisocyanurate lost 10% of its nominal R-value
boards. Using a layer of stone wool insulation as a Stone Wool System and 110°F (43°C), but most R-values are published at mean 75°F and showed decreases of up to 20%
coverboard on top of the polyiso allows the roof system Utilizing a full height stone wool system can increase the based on 75°F (24°C). Our roof boards provide after being aged in the field for three years. The stone
performance to improve. The stone wool layer moderates overall thickness of the roof system, due to the lower increased performance at cold temperatures and wool system showed no decrease in overall thermal
the temperature the polyiso is subject to and provides R-value per inch, but it can also provide additional benefits drop slightly at warmer temperatures. performance over the three-year period in the RDH study.
increased dimensional stability for the membrane. over a hybrid system. By utilizing non-combustible As the product is exposed to air, the blowing agents are
materials in the roof system, the risk of a fire event is The graph below shows the values of an average replaced with the higher conductive air, reducing overall
The hybrid system also reduces the need for hard-to use reduced and insurance premiums may be decreased. polyisocyanurate board from testing conducted by the thermal performance of the boards. The rate of expansion
coverboard materials and the number of fasteners or National Roofing Contractors Association (NRCA) and depends on many factors of the roof board but has shown
amount of adhesive required in certain systems in order In addition, the stone wool roof system has increased TOPROCK DD from a third party test. ®

to happen rapidly in the first five years of use of the board


to reduce the installed cost. When exposed to colder acoustic properties due to the fibers and mass of the before finding an equilibrium level. Polyiso products
temperatures, such as during the winter in northern stone wool roof boards. Finally, a smart membrane layer At colder temperatures, the polyisocyanurate boards
typically report their R-value as an LTTR value, which is
climates or during the night, the stone wool layer on the bottom of the roof system can be used to allow perform worse, reducing the overall effectiveness of their
a timeweighted average meant to emulate the 180-day
moderates the temperature, keeping it nears its optimum vapor to diffuse through the roof system, allowing the thermal resistance. This is most prevalent in cold climates,
R-value of other foam plastic products. However, this
temperature range. roof to dry any trapped moisture in the roof enclosure. but can also be seen at night in all climates as the
means that they will be deficient after that point and they
temperature drops. The NRCA has recommended that
will continue to drop until they reach an equilibrium point.
a design R-value of R5.0/in be used for polyiso in all
climates based on theirtesting published in early 2016. Our stone wool and other inorganic products do not use
-16˚F blowing agents, so there is no change in the composition
Membrane
of the product over time due to offgassing and stone
(R7.6) 2” TOPROCK® DD -2.4°F
10.6˚F
R-Value ASTM C518
wool shows no drop in R-value performance. We even
(R17.5)
3.5” POLYISO 40.6°F 7 provide a Limited 100% Thermal Warranty on our
products, guaranteeing that they will not drop in thermal
6 resistance over time.
75˚F

5
Apparent R-value of Roof Insulation Arrangements Based on Measurements

R-Value (hr.ft2.F/BTU.in)
Polyisocyanurate [NRCA]
of Temperature-Dependent and Aging Effects on Polyiso Insulation
-16˚F
23
4
Membrane
22
(R2.7) 0.5” WOOD FIBERBOARD -2.4°F [11-006-02732, 11-06-M0609-TH]
Stone wool roof boards provide
21
(R10) 2.5” POLYISO 7.4°F 3
20
(R12.5) 2”POLYISO 25.4˚F 47.9°F
added fireresistance and dimensional 19

stability to the roof system for


2
18 Stone Wool (Original)

added resiliency and longevity. The


Hybrid (3 Year Field Aged)
75˚F 17
Polyiso (3 Year Field Aged)
1
mass of the boards also moderate
16 Rated (Average)

the temperature of the roof and do


15
0 14
25ºF (-9ºC) 90ºF (9ºC) 75ºF (29ºC) 110ºF (93ºC)
not decrease in thermal resistance Temperature
-10
(14ºF)
0
(32ºF)
10
(50ºF)
20
(68ºF)
30
(86ºF)
40
(104ºF)
50
(122ºF)
60
(140ºF)

over time. Roofing Membrane Surface Temperature (Indoor. 21ºC, 70ºF)

Polyisocyanurate provides an increased


R-value per inch, allowing for decreased
thickness of the roof system, which can
affect the total cost and effective
performance of the system.

Return to Roofing Applications


Dimensionally Stable Sound Absorbent to
Year after Year Improve Comfort
Our stone wool is inherently dimensionally stable, as its Dimensional Stability and Membranes Sound Absorbency Reduces Distractions and Can High-performance Roof Enclosures
co-efficient of linear expansion is small compared to other As the roof boards expand and contract, membranes Improve Health To meet performance requirements of clients and owners,
materials like foam plastics. The larger the co-efficient the that are secured directly to those boards move along TOPROCK DD roof boards are able to provide
®
high-performance roof enclosures require additional
more products will expand and contract. with them, putting additional stresses on the membrane. sound attenuation benefits to low-slope roof systems. layers and resilience. Utilizing alternating layers of
Climates that experience great variance in temperatures TOPROCK DD roof boards are dual-density, providing
®
gypsum and stone wool creates additional benefits
Over time and temperature cycling, some insulating seen throughout the day and night, as well as seasonally, increased mass, and their non-directional fibers allow for in the roof enclosures. The gypsum coverboards provide
materials never return to their original size, causing gaps are at greater risk of seeing membranes fail prematurely improved sound-absorbent properties. reflectance of sound while the fibrous nature of the stone
to form between the boards. These gaps can significantly due to unnecessary stress caused by the roof boards. wool provides sound absorbency, allowing for high STC
affect the thermal performance of roof systems. Oakridge Sound absorbency is a key attribute for a number of low- or OITC requirements to be met.
National Laboratory found that 1” gaps between boards Stone wool roof boards not only have superior dimensional slope roof assemblies. Certain buildings, such as hospitals
(½” gaps from each board) caused a 10-15% drop in stability to foam plastic insulations, they also increase or schools, request additional sound absorption in order In addition, these systems provide added resiliency by
thermal performance even when two layers of insulation the thermal capacity of the roof system. This reduces the to protect the health of the occupants. Others, such as creating redundancy in the roof system to limit damage in
were used.1 peaks and valleys that the second thermal insulation layer offices or buildings near airports or other noise polluters, the case of roof leaks, a fire event or hail storms. Resilient
is exposed to. It also moderates the temperature of the desire additional sound properties in order to limit designs seek to provide more than the minimum to help
This drop in thermal performance is in addition to the membrane layer, helping to provide additional relief to the distractions or interruptions during the course of the day. owners feel comfortable that their roof enclosure will
drop expected from the temperature and the effects stresses membranes are exposed to. withstand external forces out of their control.
of aging of the roof boards, therefore the effective TOPROCK DD products can provide additional sound
®

performance differs from expected performance based reduction in combination with the other components
on the design R-value. of the roof system and work well to provide additional We have tested acoustic assemblies to
benefits for STC, OITC and other sound reduction ratings
In a third-party study by RDH Building for low-slope roofing applications.
meet a variety of performance criteria.
Roof Membrane Cap Sheet Temperatures
Science, three systems were tested in-situ For information on acoustic designs,
TOPROCK DD products also work well in metal contact your local ROCKWOOL roofing
®

in Chilliwack, BC to monitor their


90 194

80
84˚C at 13:00
176
performance over time. This graph, taken
roofing systems where rain driven and impact noise or specifications representative or
are a large concern.
70
81˚C at 13:00 80˚C at 14:00
158
in the first year of the study, highlights the contact our Technical Innovations team
60 140
thermal capacity of the stone wool and via phone at 1-877-823-9790 or by email
at contactus@rockwool.com
Temperature {ºC]

Temperature {ºF]

50 122 hybrid systems. In the hybrid system, the


40 104 peak temperature of the membrane cap
30 86 sheet is reduced by 3°C and in the stone
20 68 wool system, the peak is reduced by 4°C
10 50
and pushed an hour later. This snapshot
0 32
taken of one day is representative of the
Jun 30 00:00 Jun 30 06:00 Jun 30 12:00 Jun 30 18:00 Jul 1 00:00 moderating effects stone wool can have
B-ISO T-CAP over time to improve the performance of
B-ISO-SW T-CAP the roof membrane and help extend the
B-SW T-CAP service life of the roof.
For more information on this study, visit
Ambient Exterior

Reference: Oakridge National Laboratory. “Effects of Mechanical Fasteners and


1
rockwool.com or rdh.com
Gaps between Insulation Boards on Thermal Performance of Low-Slope Roofs”

Return to Roofing Applications


Roofing Projects
Fire Resistant
Insulation Wayne State University – Detroit, MI
In order to meet the energy demands of a growing
Flynn Canada Office Building – Toronto, ON
This office building was located near Toronto Pearson
campus, Wayne State University wanted to reduce the International Airport in Toronto, ON. To improve the
Our stone wool insulation has a melting point that Learn More: energy usage of their existing buildings by improving comfort of their office staff, Flynn Canada decided to
exceeds the temperatures of most commercial fires, Search “Comparative Roof Insulation Fire Test with Tony their roof systems. They utilized TOPROCK DD Plus on
®
improve their roof enclosure with TOPROCK DD. The
®

stone wool roofing insulation is non-combustible and Crimi” online or go to rockwool.com to see a comparison top of the existing systems or in combination with other new roof system reduced the sound transfer between
will not develop toxic smoke or promote flame spread, of common flat roof insulation types with the ASTM E119 insulations to meet their energy requirements. the nearby air traffic and the interior space, allowing for
even when directly exposed to fire. It meets the fire test. improved occupant comfort.
requirements for FM 4470 NCC (Non-Combustible
Core) rating. Therefore it will not add fuel to an existing
fire, making it ideal for high occupancy buildings or
those with particular fire concerns. Manufacturing
facilities and critical facilities that cannot be disrupted
may also desire added fire protection.

Stone wool provides passive fire protection – a strong


complement to active systems such as sprinklers. This
is important while a building is operational and just as
important in the construction and maintenance stages.

Impact and Hail


Resistant Distribution Warehouse – Quebec City, QC
This warehouse chose to perform a re-cover of their GW Williams Secondary School – Aurora, ON
existing roof in order to improve the overall energy This high school in Aurora, ON was part of a school
TOPROCK DD roof boards have two different densities
®
efficiency of their building. In order to do so they added board initiative to reduce the energy usage of their
built into the product. This allows the product to 2” of ROCKWOOL MULTIFIX to the existing roof system

buildings. 2In order to do so, they chose to use
withstand both loads asserted onto the product as well as and installed a new membrane over top. This re-cover of TOPROCK DD Plus as part of a hybrid roof system in
®

impact loads (such as hail or foot traffic). their existing roof allows them to increase performance combination with polyisocyanurate. The polyiso has a
and extend the life of the roof system without tearing off high initial R-value that decreases over time which is offset
The upper layer of the TOPROCK DD products is a
®

the existing roof or disturbing the use of the building. by TOPROCK DD Plus, providing added dimensional
®

higher-density, allowing it to deal with heavy loads, and stability and increased thermal capacity.
the lower-density layer allows the loads to be spread out
across the rest of the board with foot traffic. In addition, For more information on the impact resistance of our
the lower-density layer allows the board to return toits TOPROCK products, search for our technical bulletinon
®

original form over time after a load is removed for the subject or contact our Technical Innovations:
temporary loading such as construction materials or
foot traffic. For areas of heavy traffic or constant loading
such as paving stones, an additional coverboard layer is Phone: 1-877-823-9790
recommended based on good roofing practice. Email: contactus@rockwool.com

Return to Roofing Applications


At the ROCKWOOL Group, we are
committed to enriching the lives of
everyone who comes into contact
with our solutions. Our expertise
is perfectly suited to tackle many of
today’s biggest sustainability and
development challenges, from energy
consumption and noise pollution
to fire resilience, water scarcity and
flooding. Our range of products
reflects the diversity of the world’s
needs, while supporting our
stakeholders in reducing their own
carbon footprint.

Stone wool is a versatile material and


forms the basis of all our businesses.
With more than 11,000 employees
in 39 countries, we are the world
leader in stone wool solutions,
from building insulation to acoustic
ceilings, external cladding systems
to horticultural solutions, engineered
fibres for industrial use to insulation
for the process industry and marine
and offshore.

AFB , CAVITYROCK ,
® ®

COMFORTBATT , CONROCK ,® ®

CURTAINROCK , ROCKBOARD ,
® ®

TOPROCK , MONOBOARD , ROXUL


® ® ®

are registered trademarks of the


ROCKWOOL Group in USA and
ROXUL Inc. in Canada.

ROCKWOOL , COMFORTBOARD ,
™ ™

FABROCK , ROXUL SAFE ,


™ ™

ROCKWOOL PLUS , and AFB evo™ ™

are trademarks of the ROCKWOOL


Group in USA and ROXUL Inc. in
Canada.

SAFE’n’SOUND is a registered
®

Publication date - edition: 01/2018


trademark used under license by
Masonite Inc.

ROCKWOOL
8024 Esquesing Line
Milton, ON L9T 6W3
Tel: 1 800 265 6878
rockwool.com
ROCKWOOL Group
12
Return to Roofing Applications
TOPROCK DD Technical Data Sheet
®

TOPROCK DD
Roof Insulation 07220* • Roof Insulation 07 22 00**
® Flat Roof Insulation Mineral Wool Board Insulation 07 21 13**

Flat Roof Insulation ROCKWOOL TOPROCK® DD is a dual-density, mineral wool insulation board for flat roofing applications.

Performance Test Standard

Standard Specification for Mineral Fiber Roof Insulation Boards ASTM C726
Approval Standard for Single Ply, Polymer Modified Bitumen Sheet, Built-Up Roof and Liquid FM 4470
Compliance
Applied Roof Assemblies for use in Class 1 and Noncombustible Roof Deck Construction
NCC (Non Combustible Core) Rated Roof Insulation FM 4470

Flame spread index = 0; Smoke developed index = 0 ASTM E84 (UL 723)
Flame spread index = 0; Smoke developed index = 0 CAN/ULC S102
Determination of Non Combustibility of Building Materials - Non Combustible CAN/ULC S114
Standard Method of Fire Tests for Determining Heat Release Rate of Roofing Assemblies NFPA 276
Reaction to Fire with Combustible Above Deck Roofing Components - Class 1
Fire Tests of Roof Coverings - Class A CAN/ULC S107-03
Fire Spread under Roof Deck Assemblies - See ULC Directory CAN/ULC S126-06
Standard Test Methods for Fire Tests of Roof Coverings - Class A UL 790 (ASTM E108)
Fire Tests of Building Construction and Materials - See UL Directory UL 263 (ASTM E119)

Top Layer - 13.75 lb/ft³ (220 kg/m³) ASTM C303


Density Bottom Layer - 10 lb/ft³ (160 kg/m³) - for 2” (50.8 mm) and 2.5” (63.5 mm) thickness ASTM C303
Bottom Layer - 9.36 lb/ft³ (150 kg/m³) - for >2.5” (63.5 mm) thicknesses ASTM C303

Linear Shrinkage - 0.71% @ 1200°F (650°C) ASTM C356


Linear Change 7 days @ -40°F (-40°C), ambient RH - 0.1% ASTM D2126
Dimensional Stability
Linear Change 7 days @ 200°F (93°C), ambient RH - 0.1%
Linear Change 7 days @ 158°F (70°C), 97% RH - 0.0%

Test Standard for Susceptibility to Hail Damage - Class 1 - SH (Severe Hail) FM 4470
Hail Performance Impact Resistance by Impacting with Freezer Ice Balls - Class 4 FM 4473
Impact Resistance of Prepared Roof Covering Materials - Class 4 UL 2218

Mean Temperature R-Value RSI Value ASTM C518 (C177)


75°F (24°C) 3.8 hr.ft2.F/Btu 0.68 m2K/W
Thermal Resistance 25°F (-4°C) 4.3 hr.ft2.F/Btu 0.74 m2K/W
40°F (4°C) 4.2 hr.ft2.F/Btu 0.72 m2K/W
110°F (43°C) 3.6 hr.ft2.F/Btu 0.64 m2K/W
Dimensionally Stable
Moisture Sorption - 0.15% ASTM C1104
Low co-efficient of linear expansion means less Reaction to Moisture Water Absorption - <1.0% ASTM C209
ROCKWOOL TOPROCK® DD is a high-density, uncoated movement during temperature changes and Water Vapor Transmission, Desiccant Method - 2330 ng/Pa.s.m2 (41 perm) ASTM E96
stone wool insulation board for low-slope roof applications. no shrinking over time causing energy loss.
TOPROCK® DD is a suitable substrate board for all Top Layer - 20psi (140kPa) @ 10%, 37psi (250kPa) @ 25% ASTM C165
low-slope roof decks and is compatible as the substrate Compressive Strength Entire Board - 11psi (75kPa) @ 10%, 15psi (105kPa) @ 25%
for mechanically attached membrane systems. Point Load @ 5 mm Compression - 30psi (205 kPa) EN 12430

Stress Corrosion Cracking Tendency of Austenitic Stainless Steel - Passed ASTM C795
TOPROCK® DD is non-combustible and will not develop Corrosion Resistance
Corrosion of Steel - Passed ASTM C665
toxic smoke or promote flame spread, even when directly
exposed to fire. It can be used either as a base layer of Thickness Product available in 2” - 6” (50.8 mm - 152.4 mm) in 1/2” (12.7 mm) increments
thermal insulation in an assembly with TOPROCK® DD Dimensions 48” x 48” (1219 mm x 1219 mm)
Plus or as the top layer of a hybrid roof assembly with Thickness 125 Hz 250 Hz 500 Hz 1000 Hz 2000Hz 4000 Hz NRC ASTM C423
polyisocyanurate or other roof insulations.
Acoustical Performance 2’ 0.5 0.71 0.85 0.9 0.96 1.01 0.85
TOPROCK® DD has exclusive stone wool dual-density Contact ROCKWOOL for STC rated assemblies ASTM E90
properties that feature a higher-density top layer, providing
strong point load resistance and effective load distribution
to minimize puncture damage to the membrane –
particularly during installation.

Learn more at rockwool.com


Issued 01-01-18 NOTE: *Master Format 1995 Edition **Master Format 2004 Edition. As ROCKWOOL has no control over installation design and
Supersedes 08-23-17 workmanship, accessory materials or application conditions, ROCKWOOL does not warranty the performance or results of any
installation containing ROCKWOOL’s products. ROCKWOOL’s overall liability and the remedies available are limited by the general
terms and conditions of sale. This warranty is in lieu of all other warranties and conditions expressed or implied, including the warranties
of merchantability and fitness for a particular purpose.

8024 Esquesing Line, Milton, ON L9T 6W3


Tel: 800-265-6878 • Fax: 800-991-0110
rockwool.com
Return to Roofing Applications
TOPROCK DD PLUS Technical Data Sheet
®

TOPROCK DD PLUS
Roof Insulation 07220* • Roof Insulation 07 22 00**
® Bitumen-coated Flat Roof Insulation Mineral Wool Board Insulation 07 21 13**

Bitumen-coated Flat Roof Insulation ROCKWOOL TOPROCK® DD PLUS is a dual-density, bitumen-coated, mineral wool insulation board
for flat roofing applications.

Performance Test Standard

Standard Specification for Mineral Fiber Roof Insulation Boards ASTM C726***
Approval Standard for Single Ply, Polymer Modified Bitumen Sheet, Built-Up Roof and Liquid FM 4470
Compliance
Applied Roof Assemblies for use in Class 1 and Noncombustible Roof Deck Construction
NCC (Non Combustible Core) Rated Roof Insulation FM 4470

Flame spread index = 0; Smoke developed index = 0 ASTM E84 (UL 723)***
Flame spread index = 0; Smoke developed index = 0 CAN/ULC S102***
Determination of Non Combustibility of Building Materials - Non Combustible CAN/ULC S114
Standard Method of Fire Tests for Determining Heat Release Rate of Roofing Assemblies NFPA 276
Reaction to Fire with Combustible Above Deck Roofing Components - Class 1
Fire Tests of Roof Coverings - Class A CAN/ULC S107-03
Fire Spread under Roof Deck Assemblies - See ULC Directory CAN/ULC S126-06
Standard Test Methods for Fire Tests of Roof Coverings - Class A UL 790 (ASTM E108)
Fire Tests of Building Construction and Materials - See UL Directory UL 263 (ASTM E119)

Top Layer - 13.75 lb/ft³ (220 kg/m³) ASTM C303


Density Bottom Layer - 10 lb/ft³ (160 kg/m³) - for 2” (50.8mm) and 2.5” (63.5mm) thickness ASTM C303
Bottom Layer - 9.36 lb/ft³ (150 kg/m³) - for >2.5” (63.5mm) thicknesses ASTM C303

Linear Shrinkage - 0.71% @ 1200°F (650°C) ASTM C356


Linear Change 7 days @ -40°F (-40°C), ambient RH - 0.1% ASTM D2126
Dimensional Stability
Linear Change 7 days @ 200°F (93°C), ambient RH - 0.1%
Linear Change 7 days @ 158°F (70°C), 97% RH - 0.0%

Test Standard for Susceptibility to Hail Damage - Class 1 - SH (Severe Hail) FM 4470
Hail Performance Impact Resistance by Impacting with Freezer Ice Balls - Class 4 FM 4473
Impact Resistance of Prepared Roof Covering Materials - Class 4 UL 2218

Mean Temperature R-Value RSI Value ASTM C518 (C177)


75°F (24°C) 3.8 hr.ft2.F/Btu 0.68 m2K/W
Thermal Resistance 25°F (-4°C) 4.3 hr.ft2.F/Btu 0.74 m2K/W
Simplified Application 40°F (4°C) 4.2 hr.ft2.F/Btu 0.72 m2K/W
110°F (43°C) 3.6 hr.ft2.F/Btu 0.64 m2K/W
A pre-applied coating makes it compatible
ROCKWOOL TOPROCK® DD Plus is a high-density, with both torch and mop applied membranes Moisture Sorption - 0.15% ASTM C1104
bitumen-coated stone wool insulation board for Reaction to Moisture Water Absorption - <1.0% ASTM C209
and simplifies the application process – saving Water Vapor Transmission, Desiccant Method - 2330 ng/Pa.s.m2 (41 perm) ASTM E96
low-slope roof applications. It is compatible as the time and costs.
substrate for the following membrane attachment Top Layer - 20psi (140kPa) @ 10%, 37psi (250kPa) @ 25% ASTM C165
types: torched, hot mopped and self-adhered. Compressive Strength Entire Board - 11psi (75kPa) @ 10%, 15psi (105kPa) @ 25%
Point Load @ 5 mm Compression - 30psi (205 kPa) EN 12430
It has excellent acoustic properties and can be used
either as a top layer of thermal insulation in an assembly Stress Corrosion Cracking Tendency of Austenitic Stainless Steel - Passed ASTM C795
Corrosion Resistance
Corrosion of Steel - Passed ASTM C665
with TOPROCK® DD or as the top layer of a hybrid roof
assembly with polyisocyanurate or other roof insulations. Thickness Product available in 2” - 4” (50.8 mm - 101.6 mm) in 1/2” (12.7 mm) increments
Dimensions 48” x 48” (1219 mm x 1219 mm)
TOPROCK® DD Plus has exclusive stone wool dual-density
properties that feature a higher-density top layer, providing Thickness 125 Hz 250 Hz 500 Hz 1000 Hz 2000Hz 4000 Hz NRC ASTM C423
strong point load resistance and effective load distribution 2’ 0.5 0.71 0.85 0.9 0.96 1.01 0.85
Acoustical Performance
to minimize puncture damage to the membrane –
particularly during installation. Contact ROCKWOOL for STC rated assemblies ASTM E90

Learn more at rockwool.com

Issued 01-01-18 NOTE: *Master Format 1995 Edition **Master Format 2004 Edition***. As ROCKWOOL has no control over installation design and
Supersedes 08-23-17 workmanship, accessory materials or application conditions, ROCKWOOL does not warranty the performance or results of any
installation containing ROCKWOOL’s products. ROCKWOOL’s overall liability and the remedies available are limited by the general
terms and conditions of sale. This warranty is in lieu of all other warranties and conditions expressed or implied, including the warranties
of merchantability and fitness for a particular purpose.

8024 Esquesing Line, Milton, ON L9T 6W3


Tel: 800-265-6878 • Fax: 800-991-0110
rockwool.com
Return to Roofing Applications
MULTIFIX Technical Data Sheet

MULTIFIX
Roof Insulation 07220* • Roof Insulation 07 22 00**
Flat Roof Insulating Coverboard Mineral Wool Board Insulation 07 21 13**

Flat Roof Insulation ROCKWOOL TOPROCK® DD MULTIFIX is a dual-density, mineral wool insulation board with a glass fiber coating
for flat roofing applications.

Performance Test Standard

Standard Specification for Mineral Fiber Roof Insulation Boards ASTM C726
Approval Standard for Single Ply, Polymer Modified Bitumen Sheet, Built-Up Roof and Liquid FM 4470
Compliance
Applied Roof Assemblies for use in Class 1 and Noncombustible Roof Deck Construction
NCC (Non Combustible Core) Rated Roof Insulation FM 4470

Flame spread index = 0; Smoke developed index = 0 ASTM E84 (UL 723)
Flame spread index = 0; Smoke developed index = 0 CAN/ULC S102
Determination of Non Combustibility of Building Materials - Non Combustible CAN/ULC S114
Standard Method of Fire Tests for Determining Heat Release Rate of Roofing Assemblies NFPA 276
Reaction to Fire with Combustible Above Deck Roofing Components - Class 1
Fire Tests of Roof Coverings - Class A CAN/ULC S107-03
Fire Spread under Roof Deck Assemblies - See ULC Directory CAN/ULC S126-06
Standard Test Methods for Fire Tests of Roof Coverings - Class A UL 790 (ASTM E108)
Fire Tests of Building Construction and Materials - See UL Directory UL 263 (ASTM E119)

Top Layer - 13.75 lb/ft³ (220 kg/m³) ASTM C303


Density Bottom Layer - 10 lb/ft³ (160 kg/m³) - for 2” (50.8mm) and 2.5” (63.5mm) thickness ASTM C303
Bottom Layer - 9.36 lb/ft³ (150 kg/m³) - for >2.5” (63.5mm) thicknesses ASTM C303

Linear Shrinkage - 0.71% @ 1200°F (650°C) ASTM C356


Linear Change 7 days @ -40°F (-40°C), ambient RH - 0.1% ASTM D2126
Dimensional Stability
Linear Change 7 days @ 200°F (93°C), ambient RH - 0.1%
Linear Change 7 days @ 158°F (70°C), 97% RH - 0.0%

Test Standard for Susceptibility to Hail Damage - Class 1 - SH (Severe Hail) FM 4470
Hail Performance Impact Resistance by Impacting with Freezer Ice Balls - Class 4 FM 4473
Impact Resistance of Prepared Roof Covering Materials - Class 4 UL 2218

Mean Temperature R-Value RSI Value ASTM C518 (C177)


75°F (24°C) 3.8 hr.ft2.F/Btu 0.68 m2K/W
Thermal Resistance 25°F (-4°C) 4.3 hr.ft2.F/Btu 0.74 m2K/W
40°F (4°C) 4.2 hr.ft2.F/Btu 0.72 m2K/W
Energy-saving Performance 110°F (43°C) 3.6 hr.ft2.F/Btu 0.64 m2K/W
Low co-efficient of thermal expansion
ROCKWOOL TOPROCK® DD MULTIFIX™ is the first provides for overall dimensional stability, Moisture Sorption - 0.15% ASTM C1104
stone wool insulation product with a mineral-coated Reaction to Moisture Water Absorption - <1.0% ASTM C209
resulting in optimal thermal performance. Water Vapor Transmission, Desiccant Method - 2330 ng/Pa.s.m2 (41 perm) ASTM E96
fiberglass facer that is compatible with multiple
attachment methods including torched, hot-mopped, Top Layer - 20psi (140kPa) @ 10%, 37psi (250kPa) @ 25% ASTM C165
self-adhered, cold-adhered and liquid systems. Compressive Strength Entire Board - 11psi (75kPa) @ 10%, 15psi (105kPa) @ 25%
Point Load @ 5 mm Compression - 30psi (205 kPa) EN 12430
It can be used as an insulating coverboard over other
insulations. In these cases, it improves performance Stress Corrosion Cracking Tendency of Austenitic Stainless Steel - Passed ASTM C795
Corrosion Resistance
Corrosion of Steel - Passed ASTM C665
by regulating the temperature of the thermal insulation.
In fact, just one layer improves the performance of the Thickness Product available in 2” - 4” (50.8 mm - 101.6 mm) in 1/2” (12.7 mm) increments
entire assembly. Dimensions 48” x 48” (1219 mm x 1219 mm)

TOPROCK® DD MULTIFIX™ has exclusive stone wool Thickness 125 Hz 250 Hz 500 Hz 1000 Hz 2000Hz 4000 Hz NRC ASTM C423
dual-density properties that feature a higher-density Acoustical Performance 2’ 0.5 0.71 0.85 0.9 0.96 1.01 0.85
top layer, providing strong point load resistance and
effective load distribution to minimize puncture damage Contact ROCKWOOL for STC rated assemblies ASTM E90
to the membrane – particularly during installation.

Learn more at rockwool.com

Issued 01-01-18 NOTE: *Master Format 1995 Edition **Master Format 2004 Edition. As ROCKWOOL has no control over installation design and
Supersedes 08-23-17 workmanship, accessory materials or application conditions, ROCKWOOL does not warranty the performance or results of any
installation containing ROCKWOOL’s products. ROCKWOOL’s overall liability and the remedies available are limited by the general
terms and conditions of sale. This warranty is in lieu of all other warranties and conditions expressed or implied, including the warranties
of merchantability and fitness for a particular purpose.

8024 Esquesing Line, Milton, ON L9T 6W3


Tel: 800-265-6878 • Fax: 800-991-0110
rockwool.com
Return to Roofing Applications
Master Guide Specs
07 21 13 – Board Insulation 23 07 16 – Equipment Insulation
07 21 16 – Blanket Insulations 23 07 19 – Piping Insulation
07 22 00 – Roof and Deck Insulation

Stone wool insulation • Isolant en laine de roche

Fire Resistant Sound Absorbent Saves Energy Water Repellent Made From Stone
Résistant au feu Absorption sonore Écoénergétique Résistant à l’eau Fabriqué à partir de roche

Return to Cover

You might also like