Location via proxy:   [ UP ]  
[Report a bug]   [Manage cookies]                

32 Bit Risc Cpu Power: User Interface Panels

Download as pdf or txt
Download as pdf or txt
You are on page 1of 28

www.klinkmann.

com
User Interface Panels
for PLCs and other CPU devices

32 bit
RISC CPU POWER
low cost volume HMI
easy configuring with PC
various interfaces for PLCs, LANs,
fieldbuses, networks, wireless etc. ISO9001
JQA-1367
Programmable
Operator Interfaces
GP SERIES

Faster, Smarter, Brighter


Pro-face's New GP77 series Operator Interfaces with Super
High-Speed 100 MHz RISC CPU

Next generation programmable operator interface -


"From PLC's Face to its Brain" - the Power GP Series!

01
GP SERIES
Programmable Operator Interfaces
contents

High Performance
Interface GP77 Series 03-04
Today's rapid pace of high-tech innovation
has increased the need for industrial
GP77 Series
automation.
Standart Features 05
Pro-face's "GP Series" programmable
operator interfaces, in pursuit of more
Evolving HMI-from PLC's
comfortable communication between "Face" to its "Brain" 06
human and machines, have been striving
for the best: high performance and Allows you to monitor
advanced design. your production site
Going through a series of innovation, GP information in real time! 07
Series have gained popularity among
many users. Save Development
"From PLC's Face to its Brain" - Pro-face's Time and Space while
lineup of new concept programmable Improving Operability 08
display panels each pursues the primary
goals of the next generation of industrial GP-PRO/PB for
Windows ver. 4.0
automation, "Faster, Smarter and
Version up Features 09-10
Brighter".

GP-PRO/PB for
Windows Standart
Features 11-13

A Wide Range of
Supported Data
Formats 14
Power GP Series
Full Line up!! Fieldbus Network and
Peripheral Connections 15-16

Connections 17-18

Global Safety Standard


Complian Products 19

Global Support Network 20

Specifications 21

02
GP SERIES
Programmable Operator Interfaces
High Performance Interface GP77 Series

GP-577RT GP-577RS
100MHz RISC CPU 100MHz RISC CPU
Resolution : 640X480 pixels Resolution : 640X480 pixels
10.4 inch TFT Color LCD 10.4 inch STN Color LCD
FLASH EPROM 2MB FLASH EPROM 2MB
(Screen Memory) (Screen Memory)
32 bit RISC CPU POWER

GP-477RE GP-377RT
100MHz RISC CPU 100MHz RISC CPU
Resolution : 640X400 pixels Resolution : 320X240 pixels
Multi Unit E
(Model: GP377RT-MLTE41)
9 inch High Intensiry EL 6 inch TFT Color LCD *Only for GP-377R
FLASH EPROM 2MB FLASH EPROM 2MB 2-Way (via Ethernet)
(Screen Memory) (Screen Memory) communication
Printer I/F
CF card support

03
GP SERIES
Programmable Operator Interfaces
GP-377S GP-377L
100MHz RISC CPU 100MHz RISC CPU
Resolution : 320X240 pixels Resolution : 320X240 pixels
6 inch STN Color LCD 6 inch Monochrome LCD
FLASH EPROM 1MB FLASH EPROM 1MB
(Screen Memory) (Screen Memory)
new face

New Low-Cost, High Performance 6 inch Models

Ultra-fast 100MHz 2 times brighter *1 / 30,000


RISC CPU equipped hours *2 backlight lifetime
Quick startup and screen change for 2 times brighter display and 1.5 times
smooth operation! longer backlight lifetime.
3 times faster overall performance. *1 *1 Compared to GP-370S and GP-370L.
*2 24 hours/day use at normal operating temperatures.

High Quality Asian Fonts Back light Burn-out Detection


Chinese, Korean and For your safetly operation, the
Taiwanese fonts displayed on backlight can be monitored on the
GP377 S/L units are, front panel LED with the Touch panel
now, available with smoother Input control settings.
quality of 32X32 dots.

China Korea Taiwan


16X16 32X32 16X16 32X32 16X16 32X32

04
GP SERIES
Programmable Operator Interfaces
GP77 Series Standard Features
Faster Brighter Clearer
Fast screen changes for Clear viewing Create active and
smooth operation in bright areas vivid applications
New 100MHz chip is 3 times Both TFT and STN displays 64 color TFT and STN
faster!* are 2 times brighter!* Displays
The GP77's RISC CPU calls up and opens The GP77's screens are twise as bright as The GP77R's easy-to-read 64 color
screens in a flash, providing smooth, GP70 series units, and rival that of a display allows you to create dynamic
"no-wait" operation. standart CRT. application screens.

* Compared with GP70 series unit running demo * Compared with GP70 series.
application.

Reduces oveall debugging Adjusts to any environment


and maintenance time Select from 4 brifhtness levels*
Data transfer is twise as fast You can easily adjust the GP77's brightness
The GP77R's blistering 115.2 Kbps* speed level to fit your operation needs.
cuts your PC to GP data transfer time in a half. * GP-477RE has 2 levels of brightness
It also means you spend your valuable time
maintaining and debugging, instead of waiting
for data download or screens to change.

Type R Alarm types are


115.2Kbps
V4.0 recognizable at a glance
3 flashing speeds*
32 bit RISC CPU POWER

Screen data ON/OFF blinking speeds


are selectable (slow, medium, fast),
making alarms and data easy to
faster recognize.
GP70 Series * Available with GP-577RT, GP-577RS and
38.4Kbps GP-377RT/S only.

* Some PCs do not support 115.2kbps data transfer

Long - life backlight High speed GP - to PLC Built-in 2-port Function


communication
In additionto improved brightness, GP77 Series supports high speed The 2-port function, using the "Data
backlight lifetime is significantly longer RS-232C data transfer (115.2Kbps) Transfer Cable", and "Programming I/F
than GP 70 Series units. Backlights are Cable", allows direct connenctions
also user-replaceable ang easily PLCs supporting 115.2Kbps* between GP and Mitsubishi PLC.
changed.*1 Matsushita FP10SH This reduces your connection costs.
Mitsubishi Melcec QnA series
OMRON CS-1 * No 2-port adapter required
Sharp JW30 series

Programming
tool

GP-377 RT (50,000 hours)*2


Mitsubishi Built-in 2-port
GP-577 RT (40,000 hours)*2 PLC function
GP-377 S/L (30,000 hours)*2
GP-377 RS (25,000 hours)*2 2-port
* For more details, please contact your sales adapter
Data transfer cable
representative or Pro-face.
* 1 exept GP-377RT Ladder
* 2 Time required for backlight brightness to programming
decrease 50%
tool
Programming
I/F cable

Mitsubishi PLC

05
GP SERIES
Programmable Operator Interfaces
Programmable Operator Interface revolution!-GP77R Series

Evolving HMI-from PLC's "Face"to its "Brain"


Intelligent operator interface Past from
The GP77R Series Now

Pro-face's GP77R series units help you meet the recent Network Open Network
demands put on the workplace by ISO, PL and HACCP
requirements. Pro-face's new hardware and software Calculation

allows you to easily collect vital historical production Calculation


Data Processing
Data Processing
Data Filing
maintenence data, and helps you perform esential preven- Data Filing Communication

tive maintenence. Communication


I/O Control
Operator I/F

The newly developed GP77R panel transforms the role of


an HMI from the "face" of the PLC ti its "brain". This adds
up to significant cost and man-hour savings for the manage-
ment and control of your processing information. I/O Control

Furthemore, the combination of high-speed I/O control bet- Operator I/F

ween these units and connectable PLCs, and the GP77R's


enhanced "intelligence" ensures that your applications
perform better than ever.

Intelligent Features
Data Filing Communication
Logging Function Recipe Function 2-Way Communication
Allows you to easily report production Provides production setting data quickly to This software allows you to share data
information directly from your factory floor. PLCs in a Flexible Manufacturing System. with PLCs with ni network capability, or
Present values and process conditions can between different makes and types of PLCs.
be easily replaced at any time.
Separarte Programs
Ethernet
Ethernet Ethernet
PLC
PC Memory PC Memory Maker A Maker B Maker C
Back up Back up
Memory Memory
or or
CF card* CF card*
Printer Printer

Single Configuration
Memory Memory
PLC

PLC PLC
Memory Memory

New Products Supporting the GP77R Series Evolution


Screen editor software Data collection software
GP-577RS
GP-577RT
with Pro-Studio with Pro-Studio
(PSW-ED01-V20 or higher) (PSW-ED01-V20 or higher)

Features include the ability to Log and File PLC This software allows the GP77R to act as
information. Helps to reduce PLC ladder "Ethernet gateway" and provide programless data
programming processes/steps and amount of communication between a host PC, GP77R and
memory used. multiple different PLCs via an Ethernet network.

Large size / Medium size Multi Unit Expansion Unit

(GP077-MLTE41
(GP377R-MLTE41 (10BASE-T)
GP-477RE (Model: GP070-ET41)
GP-377RT The optional Multi Unit E Photo: Multi Unit E
expands the GP77R Series (Model: GP377R-MLTE41)
connenctivity with an
100MHz RISC CPU Ethernet I/F. CF card I/F and This interface unit
Programmable Operator Interface Sound output I/F for allows GP to transmit data with
GP77R Series P477R/DP577R and
rinter I/F for GP 377RT.
the host via Ethernet
Network.

06
GP SERIES
Programmable Operator Interfaces
2-Way Data Collection Software
Allows you to monitor your production
site information in real time!
Pro-Server with Pro-Studio V2.0
Logging Function Alarm History Function Recipe Function
Allows you to Ensures precise alarm Allows you to
easily create control. Voice alarm and easily give
daily and alarm displays are instructions and
monthly automatically executed. collect data for
Production reports production line.
Control

Provides 6 different types of program-less 2-Way data communication

2 6 3 4 5
Exchanges
data with
network PLCs.

1
Sends and Collects Sends and Sends and
Collects PLC receives GP- event receives PLC receives GP
data via acquired datra data PLC via device data via filing data via
MS Excel. R via MS Excel.R MS Access.R MS Access.R MS Excel.R

Logging Filing
32 bit RISC CPU POWER

Data data storage


storage in GP in GP
memory memory
and/or CF and/or
Work/ card CF card.
production
site Program-less data Program-less data
information. communication communication

Alarm!

A company PLC B company PLC C company PLC

Polling (Optimization Function)


Data can be read from multiple GP units simultaneously,
thereby reducing the number of data read requests from
an application. Improves data read perfomance when using
multiple GP units.

Security Function
Passwords are used to prevent data access by personel
other than system administrators, thereby protecting data
from problrms such as device overwriting, etc.

CF Card Transfer Function


Logging, filing and alarm data that has been "filed" via
the GP's screen editor software can be transfered to
another GP77R unit's CF card using an Ethernet network.*
* requires installation of Multi Unit E.

OPC Compatible (OLE for Process Control)


Microsoft's object technology OLE/ActiveX allows
manufacturing related industrial applications to be easily
connected.

Device Monitoring Function


Since PLC devices can be memored by simply selecting
a symbol, on Pro-Studio a simple simulation can be
performed prior to starting an application. With this function,
multiple screens can be displayed at one time, and the IP
address and device address can be input.

07
GP SERIES
Programmable Operator Interfaces
Save Development Time and Space while Improving Operability

Downsize and Simplify Your Application


Using the GP series keep your systems as
possible, even though your control programs get
more and more sophisticated.
The touchpanel graphic operator interface, GP
Series, is a state-of-the-arts intelligent equipment,
which has been widely installed as a main operator
panel throughout the manufacturing fields. You
can operate production systems via numerous
data and graphics displayed on the screen, while
reducing numbers of control programming
and wiring.

Simple Communication Methods


[Direct Access Method]
Simply select your target PLC when you create
screen data. The Direct Access method allows
the GP to communicate with Word and Bit
devices in the PLC memory directly. Since this
method is, also, called as a program-less
communication, there will be no extra load
on the PLC.

[Memory Link Method]


You can create your own communication
programs to connect the GP with your 0001
specialized controllers, such as single-board
0002
computers and PCs. The GP displays data
0001 0003
mapped from the host's memory for monitoring
0002 0004
and operation.
0003
0004

Create Unique Screens in Minutes

You can simply and freely create your own


operation screens for each requirement in
your applications, using a variety of powerful
tools, such as the Part Box, Tags and
D-Script macro program, on the GP-PRO/PB
||| for Windows software. The software creation
of the operator interface also, allows you easy
change, debugging and reue of the data
whenever required
Meter Graphs

ISO-7000 Symbols

Minimize Your Work for Maintenance and System Expansion


After creating data, just download it to the
GP unit, then connect the GP with the host
via a single cable for immediate operation.
Ypu can, also, simulate the GP with your PC
for quick debugging, before you take it to
the field.

08
GP SERIES
Programmable Operator Interfaces
GP Series Screen Editor Software
GP-PRO/PB ||| for Windows Ver.4.0 Version UP Features

Screen Creation and


1
POINT
Editing is Easier and More
Powerful Than Ever

Use Your Device Addresses More Efficiently


Global Cross references!
Maintenence is System Upgrades
easier than ever! Ares Easier!
(List Display) (Map Display)
All of a project's Device addresses usage
device addresses can can also be displayed as
be checked at a a chart, allowing you to
glance. easily find unused
addresses.

Quickly Check Load Screen nesting Levels


Nesting List!
Version 4.0 can create a Nesting List for complex screens
32 bit RISC CPU POWER

containing multiple Load Screens. This will speed up Your screen


editing as you no longer need to spend time searching for a load
screen's original data.

Try These Userful Functions!!


Enlarge and Move Direct Entry of Drawing Object
Objects Via Your Coordinate Values.
Keyboard Cursor To change an object's
Fine-tuning the position and position or size, just enter
layot of your screen objects on the object's coordinate
screen grid points via a mouse values, guaranteeing
Move by a dot Enlarge by a dot
could be difficult. Version 4.0 100% accurate screen
allows you to use your layot.
keyboard's arrow keys to
enlarge and move objects
easily, making detailed screen
creation and layot easier than
ever.

Cursor Position Zoom. Hairline Cursor Font selection and


Enlarges the area whwere the Use this cursor as a Mark Screens
cursor is currently positioned 3 standard when you align
Windows fonts can be
times, allowing easy editing of screen objects.
imported as character data
detailed screen drawings. to a project's Mark screens
via the font selection function,
allowing you to create
screens with a variety of
types of characters.
Pi!

m Text Images
zoo !
up

09
GP SERIES
Programmable Operator Interfaces
2
POINT
Importing/Exporting Project
Alarm Data ImprovesEfficiency CSV
Format

Alarm Editor Screen

Improve your efficiency by reducing the amount of


repetitious Alarm message editing and registration.
Version 4.0 allows easy editing and document
control via CSV format data.
Using the CSV format, alarm files can be exported to the spread sheet software such as
MS-Excel, where alarm messages can be added and edited more efficiently. Once this
work is completed, these CSV format files can be imported back to GP-PRO/PB||| for
Windows and alarm files.

3
POINT
Extended Logging/Filing/
Programming Functions

[Logging] [Filing]
Improved Data Collection Transferable data items are
via "Looping" increased
When the acquired logging data exceeds the GP's The number of data items, that can be tranferred
memory capacity, data logging can continue by at one time has been increased to 1000 words.
simply overwriting the previosly acquired logging
data. Also, logging data can be saved automatically Multible data filing Folders
to a CF Card with a simple setting. Multiple folders of filing data can be stored in both
the CF-Card and the GP's international memory.
[D-Script]
The number of data items, that can be tranferred GP-X10 Series screen data
Memory Batch Copy can be converted easily
Memory Block Initializatio Up loadded from GP-X10
units to GP-PRO/PB||| for rect
Loop Processing di
Windows V4.0 directly and
Address Offset Designator converted for the later GP GP-*10
Screen Data
models.
GP-PRO/PB||| for
Windows v4.0

4
POINT
Expanded Range of
Poweful Tools
[Wide Variety Files of Images] [Useful Sound Messages]
270 of 64-color Part images are Redy to use 270 message samples
odded for more sophiticated in the WAV format are provided.
screens of your applications. Alarm has occurred. Return loweing elevator
Confirm status. to upper limit position.
Now opening entrance Now raw materials
door. available
Starting operation. This card can not be
Temperature alarm. used.
Careful - Now rotating. Conveyer is operating.
Add material to hopper.

10
GP SERIES
Programmable Operator Interfaces
GP-PRO/PB||| for Windows Features

Intelligent operator interface


More Sophisticated
Create Screens in Minutes High-level funktionalitity Programming

1 Parts
Placement
2 Libraries
Muliple objects can be
3 Tag Setup
A wide variety of user
4 D-Script
Easy to use Macro
Select from over 1800 grouped and registered applications can be easily program reduces the
pre-made Parts. Choose for your own library. created using the Tag host controller's pro-
only the ones you need functions (active screen) gramming load.
and place them on your
screens.
32 bit RISC CPU POWER

Simulation Documentation
Reduces GP program debugging time [Automatic Documentation]
Even if you don't have a PLC available to test your new Reduces time required for creating documents
GP program, you can still quickly and easily check whether Just by selecting the items you wish to print out, you can
the program works as planned via this feature create specification and manual documents easily. You can
also use this feature to export project data in RTF format.
* This feature is not available with Memory Link selection.

Just select from menu...


All
supported
PLCs
are OK!

Export in RTF format ...and print!

File Managament
[Project Manager]
Simplifies Project Screen managament
Screen data can be managed via individual screen files.
In addition to moving or copying screen data, simply
doyble-clicking on a file name allows you to edit that
screen. You can also make data files sharable through
your PC network.

11
GP SERIES
Programmable Operator Interfaces
Simple Communication Methods
Adjustable Switch Sizes and Layot 20 pixels

Minimum Touch Switch Size: 20X20 pixels ON 20 pixels


1 or 2 point touch selectable ON MANUAL MONITOR
MANUAL

MONITOR

Parts
[1,800 Part to Choose] Touch/Switches/Lamps/Graphs/Numeric Displays/Picture Displays/
Alarm Displays/Data Displays
Over 1800 parts and symbols are
stored in the GP-PRO/PB||| library.
Just select the ones you need and Switches Tank Graphs
place them onto your application
screens.

Lamps Library Parts

[Historical Alarm Display] [Alarm Summary]


Display Types: Active, Historic, Log Allows easy machine condition monitoring and fast
Time format: hours, minutes, maintenence
and even seconds* can be displayed. Alarm Types:
* Not supported by GP270 Series summary display,
message scrolling
Printout Sub. Windows
can be easily set
Display screens can be easily printed
up for detailed in
out for daily report.
matim
* Supported only by large-sized GP units Sub-Window Image
GP377RT series
Detailed information for an individual alarm message can be
Data Storage displayed in a sub-window. You can easily create an on-line
manual for quick maintenence.
Alarm data can be backed up in GP's
backup memory.
* This feature is supported only by certain large-
sized GP and GP377 series. [Picture Display] Enable to visualizes entire
systems
[Text Display] Graphics:
Multiple character sets supported Dot, Line, Polyline, Square/
rectangle, Fill, Polygen, Circle,
Fonts: ASC|| (English and European) Oval, Arc, Pie, Scale, Mark,
Chinese, Japanese, Korean, and ISO-7000 Mark Libraries
Taiwanese fonts. Attributes:
Font Styles: Normal, Bold, Raised. Lighted, blink, reserve, off

[Image Display]
Photo and CAD images can be imported
[Graph Display]
Various Types of Graphs to Visualize Important Data
Data Foramat: 16-bit absolute/indirect data
Data Display Format: Binary, BCD
Warning Display: direct/indirect
setup for maximum and minimum
BMP image display ranges
DXF image display Graph Level Status by Colors
Importable Files Fill-Below-Line for Trend Graph
Tank Graph (Library parts)
DXF: Common file format for CAD and 3D screens Meter Graph (parts)*
BMP: Image format for pictures from digital cameras * These features not supported by GP270 series
or image scanners

12
GP SERIES
Programmable Operator Interfaces
Screen Editing
[Dublicate Copy]
Specifying the nuber of columns and
rows to be muliplied will allow you to
easily make multiple copies of any
object. Addres incrementation can
also be performed automatically.
Dublicate copy
Enlarging and
reducing
Drawing Area

[Active Window] [Video Display]


Up to 3 window screens can be Video feeds provide live data
displayed a single base screen, * This feature is only supported by GP-570VM.
all simultaneously displaying Video Display Size: standart
animated data. mode, zoom mode
Global Window: (1/screen) A
[Object Drawing] Transparent display of Video
common window for all screens Window
With a rich array of drawing Local Window: (2/screen) Unique 3 NTSC video input channels
tools, screens can be drawn window display for each screen VGA disolay (640X480 pixel)
quickly and easily - like CAD Screen overlay order can be
software. changed with a touch.
32 bit RISC CPU POWER

VM screen

VGA screen

Powerful Programming Tools

[Tags] Tag Features ["D-Script"-Macro


Programming Language]
Tags are used for the creation Touch Switch Alarm Summary
<touch panel input> <alarm summary text display> Implemet a variety of simple
of your screen animation <keyboard setup> <alarm summary display> control tasks with this
functions. 30 different tag <selector switch input> Alarm Message Display>
powerful tool
functions have been prepared <inching function> Graphic Display
Numeric Display <object drawing>
for the GP Series units. <numeric display> <library display> features include:
Combinations of these tags <static data display> <library static display> Math: +, -, *, /, Remainder,
<alarm boundary display> <mark display>
produce a wide variety of Graph Display Animated Objects
Assign
functionallity, allowing you to <graph display> <free library display> Boolean: AND, OR, NOT,
expand the scope of your <static graph display> <moving mark display> <, <=, >, >=, EQUAL,
<static data display> <rail settings>
applications. Trend Graph Display Character Display
NOT EQUAL
* Depending on the GP models, Setting Input <string display> Triggers: Timer settings,
supported Tag features variety. <key input< <display text data> Bit Rising, Bit Falling, when
<keyboard setup> Time Display
<alarm boundary> <time display> expresion becomes
Device Write True/False
<write to device>
Window Display
Functions: Load screen,Draw
<window display>
Video Window Display
<video window display>

* Some of the
above
features
are not
supported
by GP-270

13
GP SERIES
Programmable Operator Interfaces
A Wide Range of Supported Data Formats

Sound Output Function CF Card Support (Compact Flash)


An optional unit allows WAV format files Filing CSV data
(i.e. sound, alarm) to be imported to the Trend data, sampling data and alarm active/history/log data can all be
GP, and played through an external exported to the CF card using the CSV file format. Database and
speaker. This feature can be used in a spread sheet applications can then easily import this data for
variety of applications, such as multi- information managament and processing.
media, and machine operator information.
Screen Data Storage
A screen project on GP unit can be copied on a CF card for
maintenance purpose. Prior to copying the project to onather GP unit
system, set up on the GP unit is required.

Memory Expansion on CF card


In addition to the internal memory on GP unit, following data can be
stored for GP operation:
Filing Data
Logging Data
Sampling Data
Trend Graph Data
Alarm Data
Image Data
Sound Data
Screen Project Data

* Multi Unit E required

Dynamic Link between Operations and Control


Simple input/output operations can be performed
by merely dragging and dropping. You need no
knowledge of programming.

All the data required for the parts on the screen


(addresses, name plates, and names) are automatically
passed by dragging and dropping
the coresponding cymbols created on the ladder
over the screens of the GP-PRO/PB||| for
Windows. You no longer need to prepare
detailed design specifications to notify
addresses. Thos allows for impelmenting the true
integration of display and control features,
increasing the work efficiency greatly, and
reducing the number of processes significantly. Pro-Control GP-PRO/PB||| for
Editor V2.0 Windows V4.0
(under Development)

Universal File Format Support


Reduces data Duplication
BMP

Text

RTF
DXF

CSV (chart) WAV (sound)


Ve
rs
Up ion

Screen Data from all previous GP Series can be converted to the latest models, also

14
GP SERIES
Programmable Operator Interfaces
Fieldbus Network and Peripherial Connections
Direct Connection to Field Network

[Profibus-DP] [DeviceNet] [Interbus]


Profibus-DP I/F Unit (GP070-PF11) Device Net Unit (GP070-DN41) Interbus Unit (GP070-IB41)
Max.Raud Rate 12Mbps Max.Raud Rate 500Kbps Max.Raud Rate 500Kbps
Max.Node 64 Max.Node 64 Max.Node 512
Max.I/O IN : 64 Words Max.I/O IN : 127 Words Max.I/O IN : 64 Words
OUT : 64 Words OUT : 127 Words OUT : 64 Words

[Units Supported]
SIEMENS
SIMATIC S7-300/400 Series, as well as other
Profibus-DP supporting PLCs.

[Ethernet] [CC-Link] [DeviceNet]


GP Ethernet I/F Unit <10-Base-T> CC-Link I/F Unit (GP070-CL11) Device Net Unit (GP070-DN41)
32 bit RISC CPU POWER

(GP070-ET41) Max.Raud Rate 100Mbps Max.Baud Rate 500Kbps


Max.Node 64 Max.Node 64
Max.I/O IN : 128 Bits
OUT : 128 Bits [Units Supported]
Fuji Electric Co., Ltd.
[Units Supported] MICREX-F Series PLC
Mitsubishi Electric Corp. PLC
MELSEC A Series
MELSEC QnA Series

* The above communication interface modules are only for GP-470 or larger units.

Additional fieldbus Network Units Supported


Fieldbus Module *1 GP Model
QPI-ABR-201 GP47*/57* series GP470/570, GP477R/577R Series
AB Remote I/O
QPJ-ABR-201 GP270/370 series
QPI-ABD-201 GP47*/57* series GP470/570, GP477R/577R Series
AB DH+
QPJ-ABD-201 GP270 series
QPI-MDP-201 GP47*/57* series GP470/570, GP477R/577R Series
ModbusPlus
QPJ-MDP-201 GP270 series
*1 Manufactured by total Control Products, Inc.

15
GP SERIES
Programmable Operator Interfaces
GP77 Series Standard Features
[Peripheral Device Connections]

Direct Connection to Various Networks


Communication Module Interface
Direct connection to various Feield networks
becomes possible by attaching communication
modules.
Communication
Module
Real-time Operation
Auxiliary Input/ Output (AUX) (Example: GP-675T Rear face)
From the touch panel, you can send information
to the PLC or to machine's DIO I/F in real time. Communication Module Interface
(Touch output: 8 points, system alarm output: 1-puint, buzzer * Only supported by GP-47* or larger units
output: 1-point, remote reset: 1-point)
Signal Tower
* Only supported by GP-47* or larger units Buzzer, etc.

Communication whit a host Controller Auxiliary Input/Output (AUX)


Serial (SIO) Interfaces DC24V Parallel
A single cable is all you need for host I/F cable (user made)
* Only supported by GP-470 or larger units
communication, reducing maintenance time.
Host Controller
Connecting to a color Printer
Printer interface Serial Interface
RS-232C (Max 15m)
You can printout GP screens while in RUN PLC
RS-422 (max 600m)
mode. Alarm history data, including *host controller connection distances differ
trigger/recovery times can also be printed. Single board
Computer
Screen Data Transfer
Tool Connector PC

This interface is used for transfering screen data


createdby GP-PRO/PB Series. Also, you can
Printer
connect a bar-code reader to the GP.
Printer Interface
PC Screen Data
*Only supported by GP-47* or larger units
VGA Input Interface
Your PC's VGA screen can be displayed on
GP 570 VM unit.
Data Transfer Tool Connector
Cable, etc.
Video Display from Cameras Data Transfer Cable
and Recorders Memory Loader ||
Bar-code Reader
NTSC Video Input Interface (3 channels)
NTSC Video images can be displayed in a
window on certain GPs. Window display size (GP-570VM)
Connectable Barcode Readers
and position can be changed, in addition to
zooming and channel switching, from touch Make Welcome Design
panel operation or host controller. Touch Type Model 1090
(Theese features are only supported by GP-570VM unit.) Handheld Type Model 1240
Foxed Type Model 1045

VGA Input Interface (3ch)


RGB Cable (commercially available type)

CCD camera, VTR, PC


TV output, etc. VGA
Interface

Only for GP-570VM unit.

16
GP SERIES
Programmable Operator Interfaces
Connections

Connections with a PLC

Programless Communication Host controller

Connections with many different types of PLCs Data inquiry

throughout the world PLC

The direct access method supports 76 protocols for PLCs


from 25 manufacturers world wide, meeting diverse
I/O Response
requirements or customers. memory
table

Direct Connection with a PLC


Connections with Multiple PLCs Direct Connection with the CPU
Multi-link Connections Programming Port
Neither a dedicated device nor a special System configuration at low costs
program ir required The supported protocol allows the GP series unit to be connected
directly to the CPU programming port.
Multiple GP series units may be directly connected at
ease to a single host (computer) link unit for PLCs by the * Applicable PLCs: PLC MELSEC A series/QnA series/FX series of Mitsubishi
direct access method without using any dedicated device Electric Corp.
or special program.
* For multilink connections, it is recommended that our multi-link 2-port Adapter II Connected to a peripheral device
cable (GP230-IS12-O) or RS-422 terminal bracket conversion This compact adapter allows you to
adapter (GP070-CN10-O) is used. use both the GP series unit and the
PLC
PLC's peripheral units for the efficient programming
transfer, monitoring, and debugging software
Host PLC of a PLC program.
32 bit RISC CPU POWER

link unit
The direct mode can be selected RS-422 cable
Maximum extended length of for high-speed communication. for two-port
RS-422 cable: Max 600 meters adapter II
Isolated signals via 2 port Adapter II (GP070-MDCB11)
avoids noise interference to PLC'
RS-422 cable
(GP230-IS12-O) CPU. GP series

GP series GP series * The GP430-IP10-O and GP430-IP11-O are not


(up to 16 units
may be connected)
applicable
* Applicable PLCs: PLC MELSEC A series/QnA series/FX series
of Mitsubishi Electric Corp.

Memory link expansion capability:


PLC
Multiple GP units may be connected to a single personal
computer or microcomputer board.
Graphic data can be transferred from the host controller Single-board
computer Data
to the GP unit. table
The transmitted and received data can be checked for errors Memory
including those in check sums, CR, LF, ACK and NAK. table

Up to 32 GPs may be connected to a single host computer

Barcode reader

GP Maintenence
[Easy Backlight Replacement]
Service personell can easily replace the backlight
right on the factory floor, reducing maintenance time.
* Not available with GP-570L, GP-H70 and GP377RT Series units.

[Screen Data Exchange]


Memory Loader II (GP070-LC01-O) [IP65f Rating]
You can transfer GP screen data to an Flash All GP units are suitable for
Memory Card via on the Memory Loader II. installation in machines used
This allows you to update GP screen data in wet or dusty areas.
without a PC. This device is also handy for (Applies to the front panel of
duplicating applications. a unit mounted in a flat panel)
* Prior to using this tool, the GP must be set up. * Does not include GP-H70 Series unit.
* Please check the version for applicable GP unit.

17
GP SERIES
Programmable Operator Interfaces
Connectable PLCs and temperatur Controllers
Series Name CPU Link Direct Series Name CPU Link Direct Multilink DeviceNet
FANUC Power Mate (Motion Controller) Powe Mate-MODEL D O C20H O
Fanuc FANUC Series 16-MC O C28H O
C40H O
Series Name CPU Direct C120 O O
FATEK FACON FB 20MC O C120F O O
C200H O O
Series Name CPU T-Link Link Direct C200HS O O O
F30 O C500 O O
F50 O C500F O O
F60 O SYSMAC C C1000H O O
F80 O Omron C1000HF O O
F80H O O O C2000 O O
F81 O C2000H O O
MICREX-F
F120 O CQM1-CPU11 O
F120H O CQM1-CPU42 O O
Fuji F120S O CPM1-20CDR-A O O O
F200 O O SRM1-C02 O O O
F250 O CPM2A O O O
F70S O O O CS1H O
O O SYSMAC CCS1 O
NB1 CS1G
NB2 O O C200HX-CPU64 O O
FLEX-PC NB3 O O C200HE-CPU42 O O
NJ O O C200HG-CPU43 O O
NS O O C200HX-CPU85-Z O
SYSMAC
C200HX-CPU44 O
Series Name CPU Link Direct C200HG-CPU63 O
Series 90-30 CPU311/CPU331 O O C200HE-CPU42-Z O
CPU731/732 O C200HX-CPU64-Z O O
GE Fanuc Automation
Series 90-70 CPU771/772 O CV500 O O
CPU781/782 O SYSMAC CV CV1000 O O
CVM1 O O
Series Name CPU Link Direct Multilink DeviceNet
SYSMAC CS1
CS1H O O O
2 /2 E O CS1G O O O
HIDIC-S10
4 /4 F O
H20 O Series Name CPU Link
H28 O ORIM VEXTA E1 CPU11
H40 O
H64 O Series Name CPU Link Ch.O DH+ DH485 Remote I/O Multilink DeviceNet
H-200 O SLC-5/01 O
Hitachi HIDIC-H H-252C O SLC-5/02 O
H-300 O O AB SLC500 SLC-5/03 O O O
H-700 O O SLC-5/04 O O O O O
H-2000 O O O PLC-5/11 O O
Rockwell O O O
H-2002 O O O PLC-5/20 O O
H-4010 O O O PLC-5/30 O O
EH-150 O AB PLC-5 PLC-5/40 O O
PLC-5/40L O O
HIDAC EC EC-40HR O PLC-5/60 O O
S10 mini S10min O O PLC-5/60L O O

Series Name CPU Link Direct Series Name CPU Link Direct Multilink
PF2-CPU1 O JW20 O
FA-2
PF2-CPU5M O JW-32CUH O
FA-2J PF2J-CPU1 O JW50 O
Izumi PF3S-CP11 O Sharp New Satellite JW
JW70 O
FA-3S PF3S-CP12 O O JW100 O
PF3S-CP13 O O JW-32CUH1 O
MICRO3 MICRO3 O JW-32CUH3 O O

Series Name CPU Link Direct Multilink Series Name CPU Link
KZ-300 O O Shinko SELMART SELMART O
Keyence KEYENCE KZ-A500 O O
KZ-350 O O Series Name CPU Prgm Port 3964/RK512 Profibus MPI Interbus
90U O O
Series Name CPU Link 95U O O
KOSTAC SG SG-8 O S5 100U O O
KOSTAC SU SU-5/6/6B O 115U O O
KOSTAC SZ SZ-4 O 135U O O
Koyo / PLC Direct KOSTAC SR SR-21/22 O 155U O O
DL-205 D2-240 O Siemens CPU212 O
S7-200
DL-305 D3-330 O (SIMATIC) CPU214 O
DL-405 D4-430/440 O CPU312IFM O
CPU313 O O
S7-300
Series Name CPU Link CPU314 O O
P7000-PLC-001 O CPU315 O O
Matsushita Pandac 7000
P7000-PLC-031H O CPU315DP O O O
Electric Industrial P7000-PLC-031S O S7-400 CPU413-2DP O O O O
P7000-PLC-A01 O
Series Name CPU Link Multilink Ethernet
Series Name CPU Link Direct Multilink PROSEC EX EX2000 O
FP3/5 O T2E O
FP10(S) O O T2N O O
FP1 O O PROSEC T
T3 O O
Matsushita FP-M O O Toshiba T3H O O
MEWNET
Electric Works FP10SH O O B200CH O
FP2 O B200CUF O
PROVISOR B
FPQ-C32CT O O B200CURM O
FPQ-C16T O O B200CUFRM O

Series Name CPU Link Direct Multilink Ethernet CC-Link Series Name CPU Link
A2A O O O O O TCCUH O
A3A O O O O O Toshiba Machine PROVISOR TC200
TCCUL O
A2U O O
A4U O O O Series Name CPU Link 1:n
A2U-S1 O O O PC2 O
A2US O O O O O TOYOPUC-PC2 L2 O
AZUS-S1 O
Toyota O
PC2J O
AZUSH-S1 O O O O TOYOPUL-PC3J PC3J O O
A2SH O O O
A3U O O Series Name CPU 1:n
MELSEC-A A0J2 O O CB-100 Z-1021 O
A0J2H O O CB-400 Z-1021 O
A1N O O RKC CB Series CB-500 Z-1021 O
A2N O O O O CB-700 Z-1021 O
Mitsubishi A3N O O O O CB-900 Z-1021 O
A3H O SR-Mini H-RAP-A Z-1021 O
A2CJ-S3 O
A1S O O O Series Name CPU Link Direct Multilink
A1SH O O O U84 O
A1SJ O O O U84J O
A2CCPUC24 O O O U84S O
F2-20M O GL40S O
MELSEC-F2 F2-40M O Memocon SC
GL60S O
F2-60M O GL60H O
FX0 O GL70H O
FX1 O Yaskawa GL120 O O O
FX2 O GL130 O O
FX2C O CP-9200 O
MELSEC-FX FX2N-64MR O Control Pack CP-9200H O
FX2NC-32MT O CP-9200SH O
FXON-60MR O Memocon Micro Micro O
A1FX O PROGIC-8 PC01 O
FX2N O O PROGIC-8 MP930 O
FX2NC-64MR O MP920 O O
Q2A O O O
Q2A-S1 O O Series Name CPU Link Direct 1:n 1:m n:m Ethernet
Q2AS O O O FA500 O O
MELSEC-QnA Q2ASH O Yokogawa FACTORY ACE
FAM3 O O O O O O
Q2AS-S1 O O O
Q3A O Series Name CPU 1:n
Q4A O O O O SDC20 O
SDC21 O
Series Name CPU Direct Modbus Plus (n:m) SDC30 O
Modbus Master _____ O Yamataka SDC
SDC31 O
Modbus Slave _____ O SDC40A O
Modicon 884 O
O SDC40B O
884/984
984 A/B O O SDC40G O

18
GP SERIES
Programmable Operator Interfaces
High Performance Interface GP77 Series

GP77 Series

GP-577RT GP-577RS GP-477RE

GP-377RT GP-377S GP-377L


32 bit RISC CPU POWER

GP70 Series 9"/10.4"/12.1"

GP-675T GP-675S

GP-571T GP-570VM GP-570T

GP-570S GP-470E

19
GP SERIES
Programmable Operator Interfaces
GP70 Series 5"/6"

GP-370S GP-270S
GP-H70S GP-H70L
GP-370L GP-270L

CE Marked UL/c-UL Approved Units


Units
GP675T O O
12.1" GP675S
GP577RT O O
GP577RS
GP571T
10.4" GP570VM
GP570T TC21-24VP TC31-24V
GP570S SC21-24VP SC31-24V
GP477RE O O
9" GP470E EG21-24VP EG31-24V
GP377RT O O
GP377S O O
6" GP377L O O
GP370S O O
GP370L O O
GP270S SC21-24VP SC31-24V
GP270L LG21-24VP LG31-24V
5" GP-H70S O O
GP-H70L O O

Global Support Network


Pro-face HMI B.V. Scandinavia Pro-face HMI B.V.

Europe
31

Asia North
26 America
2

Pro-face UK

Pro-face America Inc.

Oceania
3
Digital Electrpnics Corp.

Pro-face HMI B.V. France

Pro-face HMI B.V. Germany

Pro-face HMI B.V. Italy


Pro-face Corea Co., Ltd.

Pro-face taiwan Co., Ltd.

20
GP SERIES
Programmable Operator Interfaces
Functional Specifications (GP77 Series Units)
Model GP577R-TC11 GP477R-EG11 GP377R-TC11-24V GP377-SC11-24V GP377-LG11-24V
GP577R-SC11 GP377R-TC41-24V GP377-SC41-24V GP377-LG41-24V
Item GP577R-TC41-24VP GP477R-EG41-24VP
Type TFT Color LCD STN Color LCD High Intensity EL TFT Color LCD STN Color LCD Monochrome LCD
Colors 64 colors (Tiling patterns make blends of colors possible) Amber 64 colors (Tiling patterns make blends of colors possible) black and white
CCFL (under normal CCFL (under normal CCFL (under normal
CCFL (under normal temperatures
temperatures and humidity, temperatures and humidity, temperatures and
Backlight _____ and humidity, lifespan = more than
lifespan = more than lifespan = more than humidity, lifespan =
30 000) User replacable.
40 000) User replacable 25 000) User replacable more than 50 000)
Resolution 640 x 480 pixels 640 x 400 pixels 320 x 240 pixels
Nominal Display Area 211.2 mm (W) x 158.4 mm (H) 192mm(W)x120mm(H) 115.2 mm (W) x 86.4 mm (H)
Attributes Blink / Reverse Video
Display Brightness Control 4 levels (via touch panel) 2 levels (via touch panel) 4 levels (via touch panel)
Contrast Control _____ 8 levels (via touch panel) ____ 8 levels (via touch panel)
ASCII: (Code Page 850) Alphanumeric (Incl. European fonts) *1
Chinese: (GB2321-80 codes) simpliefied Chinese fonts
Language fonts Japanese: ANK 158 type, Kanji: 6962 (Standard JIS Type 1 & 2)
Korean: (KSC5601 - 1992 codes) Hangul font
Taiwanese: (Big 5 codes) traditional Chinese fonts
8x8 dot font 80 characters per row, 60 rows 80 characters per row, 50 rows 40 characters per row, 30 rows
No.of
Char 8x16 dot font 80 characters per row, 30 rows 80 characters per row, 25 rows 40 characters per row, 15 rows
Display
16x16 dot font 40 characters per row, 30 rows 40 characters per row, 25 rows 20 characters per row, 15 rows
Font sizes Character size: Height and width can be expanded 1, 2, 4 or 8
Application Memory 2MB FLASH EPROM 1MB FLASH EPROM
Touch Panel (Resistive Film) 32x24 Keys / screen; 1 or 2 point touch 32x20 Keys/screen;1or2 point touch 16x12 Keys / screen; 1 or 2 point touch
32 bit RISC CPU POWER

Asynchronous transmission method: RS-232C/ RS-422


Serial Data length: 8/7 bits; 2/1 bits; stop bits: 2/1 bits
Parity: None/ Even/ Odd; Data Transmission Rate: 2400 bps to 115.2 kbps

Asynchronous Transmission Method, TTL level, non-procedural command interface


Tool Connector [during screen development] used for transferring application screen data
[during RUN mode] used as Bar-code Reader of built-in 2-port function interface
Interfaces

Touch switch output DC24Vx8 points


(inching) DC24Vx1 point
Auxiliary Input/
System alarm output DC24Vx1 point ____________
Output (AUX) Buzzer output DC24Vx1 point
Run output

Printer Output Conforms to Centronix (HP LaserJet PCL4 compatible, NEC PR Series, EPSON ESC/P or equivalent) ____________

General Specifications

Model GP377R-TC11-24V GP377-SC11-24V GP377-LG11-24V


Item GP577R-TC11 GP577R-SC11 GP477R-EG11 GP577R-TC41-24VP GP477R-EG41-24VP GP377R-TC41-24V GP377-SC41-24V GP377-LG41-24V
Input voltage AC85V to AC132V 50/60Hz DC20.4V to DC27.6V
Power Consumption 50VA or less 50W or less (TVP 20W) 20W or less (TVP 13W)
Electrical Allowable Voltage Drop Up to 20 ms Up to 2 ms
Voltage Endurance AC 1500V -20 mA 1 minute AC 1000V -10 mA 1 minute (between charging and FG terminals)
Above 10MW at DC500V Above 20MW at DC500V
Insulation Resistance Above 10MW at DC500V (between charging and FG terminals) (between charging and FG terminals) (between charging and FG terminals)
Ambient Operating
0ºC to 40ºC 0ºC to 50ºC 0ºC to 40ºC 0ºC to 50ºC 0ºC to 40ºC 0ºC to 50ºC
Temperature
Ambient Storage
-10ºC to 60ºC -20ºC to 60ºC
Temperature

Ambient Humidity 30 to 85% RH 20 to 85% RH 30 to 85% RH 20 to 85% RH


(non-condensing) (non-condensing) (non-condensing) (non-condensing)
Environmental
Vibration Resistance 10 to 25 Hz (X, Y, Z directions 30 minutes each 2G)
Noise Immunity Noise voltage: 1200Vp-p Noise voltage: 1000Vp-p
(via noise simulator) Pulse length: 1 µs; Arise Time: 1ns Pulse length: 1 µs; Arise Time: 1ns
Atmosphere Must not contain corrosive gas
Rating Equivalent to IP65f (Limited to front face of GP installed in panel)
External 317mm(W)x243mm(H) 274mm(W)x216mm(H) 317mm(W)x243mm(H) 274mm(W)x216mm(H)
x85mm(D) 171mm(W)x138mm(H)x57mm(D)
x56.5Dmm(D) x85Dmm(D) x56.5Dmm(D)
Dimensions (GP unit only) (GP unit only)
(GP unit only) (GP unit only) (GP unit only)
Structural Less than 2.5kg Less than 3.5kg Less than 2.5kg
Weight Less than 3.5 kg (GP unit only) (GP unit only) (GP unit only) (GP unit only) Less than 0.95 kg (GP unit only)
Cooling Method Natural air circulation
*1 Japanese character input requires the Japanese version screen editor software.

21
GP SERIES
Programmable Operator Interfaces
Functional Specifications (10.4" and 12.1" Display)
Model GP570-TV11 GP675-TC11 GP675-SC11
Items GP675-TC41-24VP
Type TFT Color LCD STN Color LCD
8 colors (white, red, blue, green, yellow, purple, light blue, black)
Colors Tiling patterns make blends of colors possible 64 colors (Tiling patterns make blends of colors possible)
CCFL (under normal temperatures CCFL (under normal temperatures CCFL (under normal temperatures
Backlight and humidity, lifespan = 20 000 and humidity, lifespan = 25 000 and humidity, lifespan = 25 000
hours) User replacable hours) User replacable hours) Non-replacable by user
Resolution 640x480 pixels 800x600 pixels
Nominal Display Area 211mm(W)x158mm(H) 246mm(W)x184.5mm(H)
Features Blank / Reverse Video
Display Contrast Adjustment ____ 8 levels from touch panel
ASCII: (Code page 850) Alphanumeric (Incl. European fonts) *1
Chinese: (GB2321-80 codes) simplified Chinese fonts
Language Fonts Japanese: ANK 158 type, Kanji: 6962 (Standard JIS Type 1 & ?)
Korean: (KSC5601 - 1992 codes) Hangul font
Taiwanese: (Big 5 codes) Traditional Chinese fonts
8 x 8 dot font 80 characters per row, 60 rows 100 characters per row, 75 rows
No. of
Char. 8 x 16 dot font 80 characters per row, 30 rows 100 characters per row, 37 rows
Display
16 x 16 dot font 40 characters per row, 30 rows 50 characters per row, 37 rows
Font sizes Character size: Height and Width can be expanded 1, 2, 4 or 8 times
Application Memory 1MB FLASH EPROM 2MB FLASH EPROM
Touch Panel (Resistive Film) 32x24 keys / screen;
1 or 2 point touch 40x50 keys / screen; 1 or 2 point touch
Serial Acynchronous transmission method: RS-232C/ RS-422; Data length: 8/7 bits; stop bits: 2/1 bits;
Parity: None/ Even/ Odd; Data Transmission Rate: 2400 to 38400 bps
Asynchronous Transmission Method, TTL level, non-procedure command interface
Tool Connector <during screen development> used for downloading application screens
Interface <during RUN mode> used as Bar-code Reader interface
Auxiliary Input / Output (AUX) Touch Switch Output: DC24Vx8 points; System Alarm Output: DC24Vx1 point; Buzzer Output: DC24Vx 1 point
RUN output: DC24Vx1 point; Remote Reset Input: DC24Vx1 point
Printer Output Conforms to Centronix (HP LaserJet PCL4 compatible, NEC PR Series, EPSON ESC/P or equivalent)

General Specifications
Model GP570-TV11 GP675-TC11 GP675-SC11
Items GP675-TC41-24VP
GP675-TC11: AC85 to AC132V 50/60 Hz
Input Voltage AC85 to AC132V 50/60 Hz GP675-TC41: DC19.2V to DC28.8V
AC85 to AC132V 50/60 Hz
GP675-TC11: 50W or less
Power Consumption 50VA or less GP675-TC41: 50VA or less 50VA or less
GP675-TC11: Up to 20 ms
Electrical Allowable Voltage Drop Up to 20ms GP675-TC41: Up to 2 ms Up to 20ms
AC1500V 20mA 1 minute GP675-TC11: AC1500V 20mA 1minute AC1500V 20mA 1minute
Voltage Endurance (between changing and FG terminals)
GP675-TC41: AC1000V 10mA 1 minute
(between charging and FG terminals) (between changing and FG terminals)
Insulation Resistance Above 10MW at DC500V (between changing and FG terminals)
Operation Temperature 0ºC to 40ºC
Storage Temperature -10ºC to 60ºC
Ambient Humidity 30 to 85% RH (non-condensing)
Environ-
Vibration Resistance 10 to 25 Hz (X, Y, Z directions 30 minutes 2G)
mental
Noise Immunity Noise voltage: 1200Vp-p(GP675-TC41: 1000Vp-p) Pulse length: 1 µs Arise time: 1 ns
(via noise simulator)
Atmosphere Must not contains corrosive gas
Rating Equivalent to IP65f (Limited to front face of GP installed in panel)
External Dimensions 317mm(W)x243mm(H)x85mm(D) (GP only) 346mm(W)x272mm(H)x81mm(D) (GP only)
Structural Weight Less than 3.5 kg (GP only) Less than 3.8 kg (GP only)
Cooling Method Natural Air Circulation

VM Display Specifications
Model GP570-TV11
Items
Display Colors 32768 colors
Input Channels 3 channels
Video Transmission Method NTSC
Display Number of Video Screens 1 (size, location and channel are adjustable)
Color Control tone, brightness anc contrast
Special Features still (freezes video display), transparent color settings, and zoom
Input Signal Method Analog RGB
Input Signal Synchronous Signal TTL level, negative true or positive true
Characteristics Scanning Type Non-interlaced
Flicker 8 level
Adjustment Brightness 4 level
Controls Horizontal Display Positioning -16 to 15 pixels
Vertical Display Positioning -8 to 7 pixels
Resolution 640x480 pixels
Dot-clock Range 25.175 MHz +/- 1%
* Japanese character input require the Japanese version screen editor software

22
GP SERIES
Programmable Operator Interfaces
Functional Specifications
Model GP571-TC11 GP570-TC** GP-570-SC** GP570-LG** GP470-EG**
Items

Type TFT Color LCD STN Color LCD Monochrome LCD High Intensity EL
64 colors (Tiling patterns make 8 colors (white, red, blue, green, yellow, purple, light blue, black)
Color black and white Amber (monochrome)
blends of colors possible) (Tiling patterns make blends of colors possible)
CCFL (under normal temperatures
CCFL (under normal temperatures and humidity, lifespan - 20 000 hours) *1
Backlight and humidity, lifespan - 25 000 ____
User replacable
hours) Non-replacable by user
Resolution 640 x 480 pixels 640 x 400 pixels

Nominal Display Area 211mm(W)x158mm(H) 192mm(W)x120mm(H)

Features Blink / Reverse Video


Display Brightness Control ____ 2 levels from touch panel
Functions
Contrast Control ____ 8 levels from touch panel ____

ASCII: (Code Page 850) Alphanumeric (incl. European fonts) *1


Chinese: (GB2321 - 80 codes) simplified Chinese fonts
Language Fonts Japanese: ANK 158 type, Kanji: 6962 (Standard JIS Type 1 & 2)
Korean: (KSC5601 - 1992 codes) Hangul font
Taiwanese: (Big 5 codes) traditional Chinese fonts

8 x 8 dot font 80 characters per row, 60 rows 80 characters per row, 50 rows
No. of
Char. 8 x 16 dot font 80 characters per row, 30 rows ?0 characters per row, 25 rows
Display
16 x 16 dot font 40 characters per row, 30 rows 40 characters per row, 25 rows

Font Size Character Size: Height and Width can be expanded 1, 2, 4 or 8 times

Application Memory 3MB FLASH EPROM 1MB FLASH EPROM


32 bit RISC CPU POWER

Touch Panel (Resistive Film) 32x20 keys / screen;


32 x 24 keys / screen: 1 or 2 point touch
1 or 2 point touch
Serial Asynchronous transmission method: RS-232C/ RS-422; Data length: 8/7 bits; stop bits: 2/1 bits;
Parity: None/ Even/ Odd; Data Transmission Rate: 2400 to 38400
Asynchronous Transmission Method, TTL level, non-procedure command interface
Tool Connector <during screen development> used for downloading application screens
Interfaces <during RUN mode> used as Bar-code Reader interface
Auxiliary Input / Output (AUX)Touch Switch Output: DC24Vx8points; System Alarm Output: DC24Vx1point; Buzzer Output: DC24Vx1point
RUN Output: DC24Vx1point; Remote Reset Input: DC24Vx1point
Printer Output Conforms to Centronix (HP LaserJet PCL4 compatible, NEC PR Series, EPSON ESC/P or equivalent)

General Specifications
Model GP571-TC11 GP570-TC** GP570-SC** GP570-LG** GP470-EG**
Items
GP570-*C11: AC85 to AC132V 50/60Hz GP470-EG11: AC85 to AC132V 50/60Hz
Input Voltage AC85 to AC132V 50/60Hz GP-570-*C21/ *C31: DC19.2 to DC28.8V DC19.2V toDC28.8V GP470-EG21/ EG31: DC19.2 to DC28.8V
GP570-*C11: 50VA or less GP470-EG11: 50VA or less
Power Consuption 50VA or less GP-570-*C21/ *C31: 50W or less
50W or less GP470-EG21/ EG31: 50W or less
GP570-*C11: Up to 20ms GP470-EG11: Up to 20ms
Electrical Allowable Voltage Drop Up to 20ms GP-570-*C21/ *C31: Up to 2ms Up to 2ms GP470-EG21/ EG31: Up to 2ms
AC1500V 20mA 1minute GP570-*C11: AC1500V 20mA 1minute GP470-EG11: AC1500V 20mA 1 minute
GP470-EG2124VP/ EG31-24VP:
Voltage Endurance (between changing and GP-570-*C21/ *C31: AC1000V 10mA 1 minute AC1000 AC1000V 10mA 1 minute
FG terminals) (between changing and FG terminals) (between charging and FG terminals)

Insulation Resistance Above 10MW at DC500V (between the wire and ground terminals)

Operation Temperature 0ºC to 40ºC 0ºC to 50ºC

Storage Temperature -10ºC to 60ºC

Ambient Humidity 30 to 85% RH (non-condensing) 20 to 85% RH (non-condensing)

Environmental Vibration Endurance 10 to 25 Hz (X, Y, Z directions 30 minutes 2G)


Specifications
Noise voltage: 1200Vp-p; Noise voltage: GP570-*C11: 1200Vp-p. Noise voltage: 1000Vp-p; Noise voltage: GP470-EG11: 1200Vp-p.
Noise Endurance Pulse length: 1µs; GP570-*C21-24VP/ *C31-24VP: 1000Vp-p Pulse length: 1µs; GP470-EG21-24VP/ EG31-24VP: 1000Vp-p;
Arise Time: 1ns Pulse length: 1µs; Arise Time: 1ns Arise Time: 1ns Pulse length: 1µs; Arise Time: 1ns
Atmosphere Must not contain corrosive gas

Rating Equivalent to IP65f (Limited to front base of GP installed in panel)

274mm(W)x216mm(H)
External Dimensions (mm) 317mm(W)x243mm(H)x85mm(D) (GP only) x56.5mm(D)
(GP only)
Structural
Specifications
Weight Less than 3.5 kg (GP only) Less than 2.5 kg (GP only)

Cooling System Natural Air Circulation


1) With GP570-TC21-24VP units that are Rev. E or later, the estimated lifetime of the backlight is 40 000 hours (assuming 24 hour operation).
2) Japanese character input require the Japanese version screen editor software

23
GP SERIES
Programmable Operator Interfaces
Functional Spetifications (Medium Size Display Units)
Model GP370-SC**-24V* GP370-LG**-24V* GP270-SC**-24V* GP270-SC**-24V* GPH70-SC**-24V GPH70-LG**-24V
Items

Type STN Color LCD Monochrome LCD STN Color LCD Monochrome LCD STN Color LCD Monochrome LCD
8 colors (white, red, blue, 8 colors (white, red, blue, 8 colors (white, red, blue,
green, yellow, purple, light blue, green, yellow, purple, light blue, green, yellow, purple, light blue,
Color black and white black and white black and white
black) Tiling patterns make black) Tiling patterns make black) Tiling patterns make
blends of colors possible blends of colors possible blends of colors possible

CCFL (under normal temperatures and humidity, lifespan = 20 000 hours) CCFL (under normal temperatures
Backlight and humidity, lifespan = 25 000
User replacable hours) Non-replacable by user
Resolution 320 x 240 pixels

Nominal Display Area 115mm(W)x86mm(H) 96mm(W)x72mm(H) 115mm(W)x86mm(H)

Features Blink / Reverse Video


Display
Functions Brightness Control 2 levels from touch panel __________

Contrast Control 8 levels from touch panel

ASCII: (Code Page 850) Alphanumeric (incl. European fonts) *1


Chinese: (GB2321 - 80 codes) simplified Chinese fonts
Language Fonts Japanese: ANK 158 type, Kanji: 6962 (Standard JIS Type 1 & 2)
Korean: (KSC5601 - 1992 codes) Hangul font
Taiwanese: (Big 5 codes) traditional Chinese fonts

8 x 8 dot font 40 characters per row, 30 rows


No. of
Char. 8 x 16 dot font 40 characters per row, 15 rows
Display
16 x 16 dot font 20 characters per row, 15 rows

Font Size Character Size: Height and Width can be expanded 1, 2, 4 or 8 times

Application Memory 1MB FLASH EPROM 256KB FLASH EPROM 1MB FLASH EPROM

Touch Panel (Resistive Film) 16x12 keys/screen; 1 or 2 point touch

Function Keys __________ 12


One is located on the back of the case; the other
Operation Switches __________ is the front face's function swithc (OP.) key

Push Button Switch __________ Push-Lock (E-Stop) type switch


Asynchronous transmission method: RS-232C/ RS-422; Data length: 8/7 bits; stop bits: 2/1 bits;
Serial Parity: None/ Even/ Odd; Data Transmission Rate: 2400-38400 bps
RS-232C Acynchronous Transmission Method, TTL level, non-procedure command interface
Tool Connector <during screen development> used for downloading application screens
Interfaces <during RUN mode> used as Bar-code Reader interface
DOUT: Two-point Open Controller: 5-24VDC, 50mA max
OP: One-point Controller: 5-24VDC, 50mA max
External Outputs __________ Buzzer: One-point Controller: 5-24VDC, 0.1-0.3A
Push-Lock Switch: Single B-contact, rated 30VDC, 0.3A

General Specifications
Model GP370-SC**-24V* GP370-LG**-24V* GP270-SC**-24V* GP270-SC**-24V* GPH70-SC**-24V GPH70-LG**-24V
Items
Input Voltage DC20.4V to DC27.6V

Power Consumption 20W or less (TYP10W) 12W or less (TYP8W) 12W or less (TYP10W)

Electrical Allowable Voltage Drop Up to 2ms

Voltage Endurance AC1000V 10mA 1 minute (between the live wire and ground terminals) *2

Insulation Resistance Above 20MW at DC500V (between the live wire and ground terminals)

Operation Temperature 0ºC to 60ºC 0ºC to 40ºC

Storage Temperature -20ºC to 60ºC

Ambient Humidity 20 to 85% RH (non-condensing)

Environmental Vibration Endurance 10 to 25 Hz (X, Y, Z dimensions 30 minutes 2G)


Specifiactions
Noise voltage: 1000Vp-p
Noise Endurance Pulse length: 1µs
Arise time: 1ns

Atmosphere Must not contain corrosive gas

Rating Equivalent to IP65f (Limited to front face of GP installed in panel) Equivalent to IP63

External Dimensions (mm) 171mm(W)x138mm(H)x57mm(D) (GP only) 172mm(W)x127mm(H)x58mm(D) (GP only) 237mm(W)x173mm(H)x52mm(D) (GP only)
Structural
Weight Less than 0.9 kg (GP only) Less than 0.8 kg (GP only) Less than 0.87 kg (GP only)
Specifications
Cooling System Natural Air Circulation
*1 Japanese character input require the Japanese version screen editor software
*2 With GPH70-**41-24V untits, the allowable power failure is AC500V, 10mA for 1 minute

24
GP SERIES
Programmable Operator Interfaces
Optional Items
Screen Editor Software 2-Way Comunicator Pro-Server with Data Transfer Cable Memory Loader ||
GP-PRO/PB||| Pro-Studio (Memory card included)
for Windows for Windows

Item

Catalog GPW-PB01M-V40 PSW-ED01-V20 GPW-CB02 GP070-LD-O


code
for PLC commimication for PLC commimication for GP-H70 Series for GP-H70 Series
RS-232C Cable (5m) RS-422 Cable (5m) RS-232C Cable (3m) RS-422 Cable (3m)

Item

Catalog GP410-IS00-O GP320-IS11-O GPH70-C232-O GPH70-C422-O


code (some PLCs require a different cable) GP23--IS12-O (For Multi-link)

userful for multi-link connection for easy debugging RS-422 Cable


RS-422 Connector Mitsubishi PLC for 2 Port Adapter ||
Terminal Exchange Adapter A Series/QnA Series
FX Series
2 Port Adapter ||
Item
32 bit RISC CPU POWER

Catalog GP070-CN10-O GP070-MD11 GP070-MDCB11


code
direct connection to programming port direct connection to programming port direct connection to programming port
Mitsubishi A Series PLC Mitsubishi FX Series PLC Siemens S5 Series PLC
Programming I/F Programming I/F Programming I/F
Cable (5m) Cable (5m) Cable (5m)

Item

Catalog GP430-IP10-O GP430-IP11-O GP000-IS11-O


code
connector type for GP-H70 connector type for GP-H70
RS-232C Cable RS-232C RS-422 Cable RS-422
for GP-H70 Conversion for GP-H70 Conversion
Series With Adapter Series With Adapter
D-SUB D-SUB
Item connector (3m) connector (3m)

Catalog GPH70-D232 GPH70-AP232-O GPH70-D422 GPH70-AP422-O


code
CF Card CF Card Front Maintenance Unit Protective Screen Cover

Item

Catalog GP077-CF10 (8MB) GP070-CFFM10 GP370-DC10


code GP077-CF20 (16MB) (Under development)

Cover Sheets Backlight Bulbs User's Manual

Item

Soft Type Hard Type GP675S-BL00-MS GP-H70(S/L) GPH70-MM11-STD-ENG


10 sheets / set 5 sheets / set GP675T-BL10-MS GP-270(S/L) GP270-MM11-ENG
GP570-COVER-10P GP675-DF10-O GP570-BL00-MS *1 GP-370(S/L) GP370-MM11-ENG
GP470-COVER-10P GP570-DF10-O GP577RT-BL00-MS GP-470E GP470/570-MM21-ENG
Catalog GP570/577-COVER-10P
GP470/477-COVER-10P
GP470-DF10-O
GP570/577-DF10
GP370-BL00-MS
GP270-BL00-MS
GP-570(T/S/L)
GP-571T
GP470/570-MM21-ENG
GP470/570-MM21-ENG
code GP470/477-DF10 GP-675T GP675-MM21-ENG
20 sheets / set 10 sheets / set *1 With GP570-TC21-24VP units that are Rev. E or GP-477R/577R GP477R/577R-MM11-ENG
GP370-COVER-20P GP370-DF10-O later, use backlight GP-377R GP377R-MM11-ENG
GP270-COVER-20P GP270-DF10-O model: GP577RT-BL00-MS GP-377(S/L) GP377-MM11-ENG
GPH70-DF10-O

25
GP SERIES
Programmable Operator Interfaces
Operation Enviroment for Software
GP-PRO/PB||| Windows Pro-Server with Pro-Studio
PC IBM Compatible PC IBM Compatible
OS Version MS-Windows 95/98/NT OS Version MS-Windows 95/98/NT
Memory 16MB, or higer Memory 16MB, or higer
30MB minimum Disk Space 10MB or higer
Disk Space
53MB maximum *1 Mouse Windows 95/98/NT compatible
Mouse Windows 95/98/NT compatible Printer Windows 95/98/NT compatible
Printer Windows 95/98/NT compatible *2 Ethernet 10BASE-2/5T
*1 40MB maximum for CD-ROM version Protocol TCP/IP
*1 Printers with only Windows drivers cannot be used. Others Ethernet Hub, Ethernet cable

External Dimensions (mm)

GP-675 GP-577RT GP-571T


GP-675S GP-577RS GP-570VM
GP-570T
(top)
331.0 301 GP-570S
GP-570L
Panel Cut-out
7.5 81 Panel Cut-out
+1 (top) 85
346 259 -0
7.5
317 302+0.5-0.5
123.5+1-0

-0.5
+0.5
272

275

243

227

228
under 4-R2 under 4-R2

(front) (side) (front) (side)

GP-477RE GP-377RT GP-377S


GP-470E GP-377S GP-370L
GP-377L
258 155.5
(top)

Panel Cut-out
(top) Panel Cut-out 57
274 56.5 171 5 156+1-0
7.5
+1
259 -0
123.5
123.0
-0

138
200
216

+1
201

under 4-R3
under 4-R2

(front) (side) (front) (side)

GP-270S GP-H70S
GP-270L GP-H70L
157.5
52

(top) 58 Panel Cut-out


5 (top) MAX68
237
172
158+0.5-0
112.5
127

-0
+0.5

173
113

under 4-R3

(front) (side) (front) (side)

26
GP SERIES
Programmable Operator Interfaces
The Family-HMI yhat you can count on
Flat Panel Display
Panel Computer PL Series FP Series
IBM Compatible Industrial Panel Computers Panel Displays that can replace your CRT, keyboard
PL-X900 Ñåðèÿ and mouse, and save valuable space
PL-6700 Ñåðèÿ

FP-570T
PL-3700S
PL-5700 Ñåðèÿ Äèñïëåé VGA

FP-770T/FP-775S
Äèñïëåé XGA

PL-B900 Ñåðèÿ Graphic Panel GP Series


Programmable Operator Interface for Industrial Controllers

Graphic Logic Controller


GLC Series
Programmable Operator Interface with I/O
control features.

GP77R ñåðèÿ GP70 ñåðèÿ GP-PRO/PB III


100 MHz RISC CPU è 32 áèò RISC CPU Äëÿ Windows
2 ñïîñîáà ïîäêëþ÷åíèÿ ê ñåòè Ýêðàííûé ðåäàêòîð

GLC300T Pro-Control ðåäàêòîð

GLC100 Ñåðèÿ

Klinkmann - total solution for HMI


Wonderware InTouch is with 150.000
installations world leading HMI/SCADA PC
software. InTouch is part of Wonderware
FactorySuite , which offers also Industrial
SQL Server automation database,
SuiteVoyager automation internet portal,
Terminal erver thin client server, InControl
SoftPLC etc.
Klinkmann's development develop interface
and wireless automation software for
various automation devices incl.
Siemens, ABB, Profibus, Interbus and
thernet. Klinkmann software is used in
over 60 countries araound the world.

POB 38 FIN-00371 Helsinki, Finland


ph. int. +358-9-540 4940
fax int. +358-9-541 3541
e-mail: automation@klinkmann.fi
WEB : www.klinkmann.com

You might also like