SPECIFICATION SHEET

Airco inverter chiller units (AIV)


AIRCO INVERTER CHILLER UNITS 2

AIRCO INVERTER CHILLER UNIT


TECHNICAL FEATURES

MAR-IX inverter chiller units are designed in such way


- Equipped with variable capacity rotary compressor
that all refrigeration components are placed in a
- Filled with environmental friendly refrigerant
stainless steel housing. This ensures sound reduction
- Mainly manufactured from stainless steel
and protection of the chiller against conditions in an
- Sea water resistant condenser
engine room or other technical space. A major - Sea water resistant water pump
advantage of the compact design it that the chiller - Standard equipped with vibration absorbers
occupies little space. - Pressure and temperature protected
- Low current
The MAR-IX AIV series chiller units are equipped with - Quiet operation
inverter technology which means that the chiller will - Compact system
not switch on and off the compressor, but varies in - No current peak at start-up
speed to control the cooling capacity. By using - Energy saving
this inverter technology current peaks belong to the
past and the electric system on board the ship will not
be disrupted. AIV units are standard suitable for the
most common power supplies, and will function on 50
STANDARD SUPPLY
as well as 60Hz.

All units are equipped with a sea water-cooled - Chiller unit


condenser made of copper/nickel. Optionally available - User manual
is a high efficient condenser that can be connected - Spare part list
directly to a box cooler. - Declaration of Conformity
- Test Certificate
The AIV series chiller units can be connected to all
MAR-IX fan coil units and controlled by our electronics
with or without communication.
OPTIONAL
If the AIV chiller is connected to the MAR-IX
communication system, the chiller will also adjust its
capacity to the power requirements of the areas which - Sea water kit
are being cooled. The chiller will not deliver more - Circulation pump
cooling capacity than what is actually demanded for, - Marine approved air hose, thermal and acoustic
which relieves the electric power consumption. - insulated
AIRCO INVERTER CHILLER UNITS 3

GENERAL DATA

Power supply Power supply Cool Refrigerant Current Power (W) Req. Chilled water Min. req. Max.
AC DC capacity flow @ 6-12°C sea water flow Sea water temp.

220-240V
12-24V 3.400-17.000 Btu R407C 1.5 - 5 A 1 - 5 Kw 0,7 m3/hr 0,6 m3/hr 40 °C
50-60Hz

220-240V
12-24V 6.800-27.300 Btu R410A 2-8A 2 - 8 Kw 1,12 m3/hr 1,0 m3/hr 40 °C
50-60Hz

220-240V
12-24V 6.800-34.100 Btu R410A 10 - 12 A 2 - 10 Kw 1,4 m3/hr 1,25 m3/hr 40 °C
50-60Hz

220-240V
12-24V 6.800-51.200 Btu R410A 2 - 15 A 2 - 15 Kw 2,1 m3/hr 1,9 m3/hr 40 °C
50-60Hz

400V / 50-60Hz
12-24V 13.600-68.300 Btu R410A 9A 4 - 20 Kw 2,8 m3/hr 2,5 m3/hr 40 °C
(3ph+N+Pe)

400V / 50-60Hz
12-24V 13.600-85.300 Btu R410A 9A 4 - 25 Kw 3,5 m3/hr 3,1 m3/hr 40 °C
(3ph+N+Pe)

400V / 50-60Hz
12-24V 13.600-102.300 Btu R410A 8 - 11 A 4 - 30 Kw 4,2 m3/hr 3,75 m3/hr 40 °C
(3ph+N+Pe)
AIRCO INVERTER CHILLER UNITS 4

DIMENSIONS & WEIGHTS

A B C F G H N1 N2 N3 N4 Weight
(mm) (mm) (mm) (mm) (mm) (mm) Chilled fluid in Chilled fluid Sea water in Sea water out
out

534 264 407 515 265 Ø7 ¾” BSP OT ¾” BSP OT ¾” BSP OT ¾” BSP OT 40 kg

534 264 442 515 265 Ø7 ¾” BSP OT ¾” BSP OT ¾” BSP OT ¾” BSP OT 48 kg

445 400 436 416 396 Ø7 ¾” BSP IT ¾” BSP IT ¾” BSP OT ¾” BSP OT 55 kg

630 387 596 596 384 Ø7 1” BSP IT 1” BSP IT 1” BSP OT 1” BSP OT 60 kg

709 441 687 687 444 Ø9 1” BSP IT 1” BSP IT 1” BSP OT 1” BSP OT 110 kg

709 441 687 687 444 Ø9 1” BSP IT 1” BSP IT 1” BSP OT 1” BSP OT 110 kg

709 441 687 687 444 Ø9 1” BSP IT 1” BSP IT 1” BSP OT 1” BSP OT 110 kg

Note:

Dimensional sketch AIV5 thru AIV15 on page 6


Dimensional sketch AIV20 thru AIV30 on page 7
AIRCO INVERTER CHILLER UNITS 5

DIMENSIONAL SKETCH – AIV5/AIV8/AIV10/AIV15

B A

C N3 N4

N2 N1

D
AIRCO INVERTER CHILLER UNITS 6

DIMENSIONAL SKETCH – AIV20/AIV25/AIV30

B A

N1

C N4

N3
N2

D
Loofklapper 14 - 8256 SL Biddinghuizen - The Netherlands
Tel.: +31(0)321-337467
Web: www.mave.nl - Email: info@mave.nl