NOTES

1. THIS DRAWING SHALL BE READ WITH ALL RELEVANT


ARCHITECTURAL AND ENGINEERING DRAWINGS.
2. THE REINFORCEMENT SHALL UNLESS SPECIFIED
OTHERWISE BE MILD STEEL COMPLYING WITH B.S.4449
WITH YIELD STRESS OF 250 N/mm2 OR SIMILAR APPROVED.
3. ANY CONSIGNMENT OF STEEL INTENDED TO BE USED ON
THIS PROJECT SHALL BE ACCOMPANIED BY MANUFACTURER'S
TEST CERTIFICATE STIPULATING THAT THE ABOVE
SPECIFICATION HAS BEEN COMPLIED WITH.

4. NOT WITHSTANDING THE PROVISION OF No.3 ABOVE,THE


THE CONTRACTOR SHALL AT HIS OWN COST AND AS
DIRECTED BY THE ENGINEER SUPPLY SAMPLES FOR
THE TENSILE AND OTHER RELEVANT TESTS.
5. ANY CONSIGNMENT NOT MEETING THE SPECIFICATIONS
ABOVE SHALL BE REMOVED FROM THE SITE WITHIN 24
HOURS UPON NOTIFICATION TO DO SO BY THE ENGINEER.
6. N0 REINFORCEMENT BAR SHALL BE WELDED WITHOUT
THE WRITTEN PERMISSION OF THE ENGINEER. BEFORE ANY
WELDING IS CARRIED OUT, DETAILS OF WELDING PROCESS
SHALL BE SUBMITTED TO THE ENGINEER FOR HIS
APPROVAL OR OTHERWISE.
7.
1 2 3 4 5 5a 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25
CONCRETE COVER FOR MAIN REINFORCEMENT SHALL
UNLESS SPECIFIED OTHERWISE BE AS FOLLOWS :-
I. FOUNDATIONS................ 75mm
II. COLUMNS ......................50mm
III. BEAMS......................... .50mm
IV. SLABS...........................25mm
V. STAIRCASES...................25mm

8. COARSE AGGREGATE SHALL CONSIST OF CRUSHED ROCK


OF EITHER GRANITE BASALT OR QUARTZITE.
9. FINE AGGREGATE SHALL CONSIST OF SAND OR CRUSHED
ROCK ONE OR MORE OF TYPES GIVEN ABOVE OR CRUSHED
GRAVEL AND SAND.
10. THE AGGREGATE SHALL NOT CONTAIN ANY HARMFUL
MATERIAL IN SUFFICIENT QUANTITY TO AFFECT ADVERSELY
THE STRENGTH, WEAR RESISTANCE OR DURABILITY OF
THE CONCRETE.
2500 6075 25001250 1550 846 2404 796 1350 2654 896 1904 896 1104 2050 4800 2000979 2800 1350 3450 1150 4150
1150 1154 11. THE MAXIMUM SIZE OF AGGREGATE SHALL BE 40mm
GRADED DOWN TO 5mm.

12. THE VARIOUS SIZE OF PARTICLES OF WHICH AN


AGGREGATE IS COMPOSED SHALL BE UNIFORMLY
DISTRIBUTED THROUGHOUT THE MASS.

13. CONCRETE IN BLINDING SHALL HAVE A MAXIMUM


AGGREGATE SIZE OF 20mm. A MINIMUM 28 DAYS CUBE
STRENGTH OF 10 N/mm2.
14. CONCRETE IN FOUNDATION SHALL HAVE A MAXIMUM

A B AGGREGATE SIZE OF 40mm. AND A MINIMUM 28 DAYS


CUBE STRENGTH OF 30 N/mm2.
15. CONCRETE IN COLUMNS, BEAMS AND FLOOR SLABS SHALL

A A HAVE A MAXIMUM AGGREGATE OF 20mm. AND A MINIMUM


28 DAYS CUBE STRENGTH OF 30 N/mm2.

E8
1350

1350
E1 E4 E6 E7 E9 E10
16. MECHANICAL VIBRATORS SHALL BE USED THROUGHOUT
ALL CONCRETE OPERATIONS.

B B 17. ALL REINFORCEMENT SHALL UNLESS OTHERWISE


DIRECTED, BE BENT ON SITE.
18. STRUCTURAL TIMBER SHALL BE WELL SEASONED ODUM
FREE FROM ALL DEFECTS AND COMPLYING WITH THE
1875

1875
CURRENT B.S.112 OR SIMILAR APPROVED.

19. I.D INDICATES INTERNAL DIMENSION

C C
C
875

875
D D
E14
2050

2050
E D G H K E
E3
975

975
F F
600 1350 300 1350 263 500 1075

600 1350 300 1350 263 500 1075


G G
HA C H
338

338
J K K J
E2 E5 F2 F1 E13 E12 E11
L L
M A B M
N N
P P
2000

2000
Q Q
L1 L2 L2 L1
REVISION
FOR CONSTRUCTION
ABP CONSULT LTD.

2500 6075 1250 1250 1550 846 2404 796 1350 2654 896 1904 896 1104 2050 2754 1021 979 1450 1350 3450 696 1150 1150 1154 P. O. Box 7186, Accra-North, Ghana
Tel: (233-302) 773078, 773081, 773093
Fax: (233-302) 773094
E-mail: abp@abpconsult.com
In Association with
EDIV CIVIL ( 2016 )
1 2 3 4 5 5a 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25
Client:

SETTING OUT KNUST SCHOOL OF


ENGINEERING
Project

Title : ADMINISTRATION BLOCK


SETTING OUT PLAN

DRN: A.A CKD: A.A APP Revision

Scale:1:100 Job No Drg No


Date:
FEB. 2010 BD.160 ARC/01