Technical Data

190-600V DIESEL 01-01-2012

CUMMINS Alternator: Leroy-somer


TCM450 (Open)
Engine: LSA47.2S5 Generator
KTA19-G3 Optioanl: Stamford HCI544C Model:
Electronic Governor TCM450C (Silent)
Tide TPA354S1

50Hz 3 Phase Power Factor: Emissions


N/A
1500 r.p.m 4 Wires Cos ¢ = 0.8 Certification:

Prime Power Standby Power Rated Current


RATINGS (PRP) (LTP) (A)
Voltage (V) kW kVA kW kVA Amps
440/254 360 450 400 500 590.5
415/240 360 450 400 500 626.1
400/230 360 450 400 500 649.5
380/220 360 450 400 500 683.7

RATINGS:
All three Phase generator sets are rated at 0.8 power factor. All single-phase generator sets are rated at 0.8 or 1.0 power
factor. TIDE Power reserves the right to change the design or specifications without notice and without any obligation
or liability whatsoever.
Prime Power:
Standby Power:
Available continuously at variable load in lieu of
Emergency Standby Power in variable load applications in
commercially purchased power for an unlimited number
accordance with ISO8528-1 in the event of a utility power
of hours per year in accordance with ISO8528-1, and an
failure. No overload available for this service as relevant
overload of 10% permitted for one hour in every twelve
alternators are peak continuous rated at 27℃.
hours of operation in accordance with ISO 3046-1.

Distributed by City Generators 35A Technology Drive Warana 4575 QLD, Australia for Tide Power System Co., Ltd.
Ph (07) 54923220 Web www.citygenerators.com.au
Standard Features
▲ High efficient water cooled diesel engine ▲ Radiator with cap and drain point.
▲ Brushless alternators (Class H, with AVR.) ▲ Fully guarded engine driven fan
▲ Heavy duty rubber anti-vibration mountings ▲ Circuit Breaker - 3 pole (MCCB)
▲ 12/24V starter batteries and connecting cables ▲ Base fuel tank for 6 - 8 hours running at 100% load
▲ Separate engine-drive battery charging alternator ▲ Oil filter - Diesel filter - Air filter
▲ Industrial silencer for open type generator sets ▲ Fully welded steel baseframe with lifting and
▲ Residential silencer for open type generator sets fork-lifting facilities.
▲ Auto start / Digital Tide Easycon Control Panel ▲ Sound proof & Weather protective enclosures for
▲ Wiring with IEC standard silent type generator sets.
▲ Factory Test Certificate
▲ Operation & Maintenance Manual & Diagrams
▲ Worldwide Product / Technical Support

Optional
△ Automatic Transfer Switch (ATS) △Extra air filters for time-maintenance
△ Water - fuel separator △Extra diesel filters for time-maintenance
△ Water heater for severe cold weather △Extra oil filters for time-maintenance
△ Lub-oil heater for severe cold weather △Separated standing fuel tank
△ 50℃-60℃ Radiator △Low coolant level sensor
△Dual wall fuel tank base △Full range of attachments and options available
△Fuel level sensor for alternator
△Maintenance free battery
△Additional CE Features Selection

Overall Dimensions (mm) & Weight (kg)

Open Type Silent Type

Length: Length:
3150 4700
Width: Width:
1300 1600
机组尺寸简图由技术部提供
Height: Height:
2100 2250
Weight: Weight:
3850 5500
Dimension and design are subject to change without notice.
Warranty

The goods of Tide Power System are under warranty against defects in materials and
workmanship for a period of 12 months or 1000 hours whichever come first from the
date of delivery to the end user (except the damageable spare parts of genset caused
by incorrect man-made operation), and that the aforementioned warranty for the same
token is back up by the engine & alternator manufactures and their global distributors.

Distributed by City Generators 35A Technology Drive Warana 4575 QLD, Australia for Tide Power System Co., Ltd.
Ph (07) 54923220 Web www.citygenerators.com.au
Engine Specification 50HZ

General Performance Lubrication System


Manufacture CCEC Cummins Oil Pan Capacity(High-Low) 38-32 Litres
Engine Model KTA19-G3 Maximum Oil Temperature 121℃
Engine Type 4 cycle, in-line, 6-cylinder Maximum Oil Consumption N/A
Engine Speed 1500 r.p.m Total System Capacity Including Bypass Filter 50 Litres
Base Output Power 403kW/540hp
Standby Power 448kW/600hp Fuel System
Governor Type Electronic Type Injection System Direct Injection Cummins PT
Air Intake Way Turbocharged and Aftercooled Fuel Consumption at 100% Standby power 107 Litres/hour
Displacement 18.9L Fuel Consumption at 100% Prime power 97 Litres/hour
Cylinder Bore * Stroke 159mm × 159mm Fuel Consumption at 75% Prime power 73 Litres/hour
NO. of Cylinders 6 Fuel Consumption at 50% Prime power 51 Litres/hour
Compression Ratio 13.9:1 Fuel Consumption at 25% Prime power 30 Litres/hour
Engine Idle Speed 675-775 r/min Fuel Tank Capacity
Piston Speed 7.9 m/s - Open Type Genset 6 Hours at Full Load
Intake Air Flow 533 Litres/sec. - Silent Type Gensets 582 Litres
Air Clearner Type Dry
Cooling System
Exhaust System Coolant Capacity - Engine Only 30 Litres
Exhaust Gas Flow 1489 Litres/sec. Standard Thermostat (Modulating) Range 82 - 93℃
Exhaust Gas Temperature 524 - 532℃ Maximum Top Tank Temperature
Maximum Back Pressure 10kPa/76mm Hg - Standby Power 104℃
Exhaust Pipe Size 127mm - Prime Power 100℃

Air Intake System Electric System


Recommended intake piping size N/A Electrical System Voltage 24V
Maximum Intake Air Restriction Battery Maintenance-free
- Dirty Element 635mm H2O Connecting Cables Auailable
- Clean Element 254mm H2O
Thermal
Radiated Heat to Ambient 58-64kW
Heat Rejection to Coolant 247-274kW
Heat Rejection to Exhaust 263-287kW
Alternator Specification
General Data 50HZ/1500R.P.M
Manufacture / Brand Leroy-somer Prime Output Power 364kW/455kVA
Model LSA47.2S5 Standby Output Power 400kW/500kVA
AVR Model R250 Insulation class H
Coupling / Bearing Direct / Single Bearing Voltage regulation ± 0,5 %
Phase 3 Phase Total harmonic TGH / THC at no load<1,5 %-on load<2%
Power Factor Cos¢ = 0.8 Wave form : NEMA = TIF - (*) < 50
Winding pitch - Code 2/3 - (N° 6) Wave form : I.E.C. = THF - (*) <2%
Drip Proof IP 23 Altitude ≤ 1000 m
Excitation Shunt Overspeed 2250 min -1

Distributed by City Generators 35A Technology Drive Warana 4575 QLD, Australia for Tide Power System Co., Ltd.
Ph (07) 54923220 Web www.citygenerators.com.au
TIDE Easycon Control Systems “Let your Generator always in Control”

TIDE Power comprehensive Easycon range control panels are compact, versatile and easy to use.

Easycon 2.0L/H (GU601A / Deepsea DSE3110) panel is a key-start


auto control panel, it’s a basic control panel fits for generators up to
100kVA to provide basic operating parameters display and
protection.

Easycon 3.0 L/H (GU641B / Deepsea DSE7210) panel is an


auto & digital control panel, it’s an entry level control panel
which provides full power monitoring and protection facilities.
All operating parameters are with LCD display.
(Auto Main Failure Version DSE7220 also Available.)

Easycon 4.0L/H (GU620A / Deepsea DSE7310) panel is an


auto & digital & Remote control panel which includes all the
features of Easycon 3.0, and plus data communication of full
telemetry via the RS232/RS485 interfaces, CANBus is
also included.
(Auto Main Failure Version DSE7320 also Available.)

Specifications
2 Over Speed pre-alarm & shutdown - Auto Start -
. Low Oil Pressure Pre-Alarm & shutdown - Oil Pressure -
3 0 High Water Temp. Pre-alarm & shutdown - Genset Running Hours -
4 . L Volts, Current, Frequency, Rpm (Instruments)- Battery Voltage and Charging -
. 0 / Fuel Sensor as optional -
0 L H AMF Module as optional -
L / Digital Control Panel - Switch Opening as Optional -
/ H Overcurrent Pre-alarm - AMF Module as optional -
H Overcurrent Shutdown - Power Factor -
Prefix Start, Service Indicate, Fault History for Deepsea Module.-
Remote Start (Data communication of full telemetry via the RS232/RS485) -
CANBus -

Options
Easycon 5.0H (Deepsea DSE8610) panel fits for Easycon 6.0H (Deepsea DSE8620) panel fits for Single Gen
Gen-Gen automatic Synchronising and load sharing. - Mains automatic Synchronising.

Deepsea DSE7560 Synchronising Controller for Multi


gen – Mains Synchronising. This is a separate control (For details specifications of Control Panels,
unit which enables multiple Easycon 5.0 equipped Gens please consult our sale department.)
to be synchronised with the Mains supply.

Distributed by City Generators 35A Technology Drive Warana 4575 QLD, Australia for Tide Power System Co., Ltd.
Ph (07) 54923220 Web www.citygenerators.com.au
Circuit Breaker 3 Pole MCCB - Standard (4 Pole as optional)

The generators are supplied together with a circuit breaker that permits a thermal protection against overloads and
magnetic protection against short-circuit.

Automatic Transfer Switch A.T.S - 4 Poles

TIDE Power offers not only a changeover switch but also an


integrated mains detection and switch system for your 24 Hour Power
Protection. The system enables automatic start-up and operation of the
generating set in the event of a mains power failure, overvoltage or
loss of phase; and also mains automatic re-transfer once it come back.

ATS: Automatically transfer and re-transfer load from main power to


gen-power without operator intervention. (Both Automatic and manual
operation.)
Please consult our sales department for specifications.

Enclosure / Canopy (Sound-attenuated & Weather Protective)

“Ensure a quieter life with our sound attenuation system.”


Features:

Extremely Rugged & Security and Safety


Highly Corrosion ResistantConstruction ▲Earth leakage protection
▲Body made from 2.0mm sheet steel components ▲40-50mm non-inflammable sponge inside
with powder coating ▲Control panel viewing window in a lockable access door
▲8-12 hours built-in fuel tank integrated ▲Emergency stop button mounted on canopy exterior

into the skid-mount base ▲Fuel fill and battery can only be reached via lockable
▲Excellent design and craftmanship access doors
▲Zinc alloy with black powder coated ▲Exhaust silencing system enclosed for operator safety

or Bright polished stainless steel hinges tested ▲Excellent cooling system to avoid high water temp.,

and proven to withstand corrosive conditions. reliable operation under harshest conditions.
▲Compact structure and longer service life ▲(Ambient temp.upto 40-52℃ and altitudes up to 1000M)

Easy Commissioning and Maintenance Transportability


▲Separate & Standing control cabinet at one side, ▲Lifting points on baseframe

quick fix electrical power connections. ▲Lifting shelf as optional


▲Lube oil drain and radiator drain
▲Side doors allowing 180°opening rotation Quiet (Reduce Sound and Vibration)
▲Radiator fill access through cover in canopy roof. Noice Level:
△Sockets and Lifting shelf as Optional 77-88dBA at 1m & 67-78dBA at 7m

Distributed by City Generators 35A Technology Drive Warana 4575 QLD, Australia for Tide Power System Co., Ltd.
Ph (07) 54923220 Web www.citygenerators.com.au

You might also like