Wallaby 

Metering Systems Pvt. Ltd. 

Display Parameters List – MSEDCL ABT

Sr.No. Name of Display Parameters On Meter Display

MODE -A Auto Scroll Mode

1 Display Check LCD test


2 Unique Identification Number Serial No

3 Phase Sequence of Voltage and Current Volt Curr Seq

4 Cum.kWh Import CUM Imp kWh'


5 Rate A kWh Import Rate A kWh Imp
6 Rate B kWh Import Rate B kWh Imp'
7 Rate C kWh Import Rate C kWh Imp'
8 Rate D kWh Import Rate D kWh Imp'
9 Cum.kVArh Import Lag 'CUM kVArh ImpLg'
10 Cum.kVArh Import Lead 'CUM kVArh ImpLd'
11 Cum.kVAh Import 'CUM kVAh Imp'
12 Average Power Factor Import Avg PF Import'
13 Rate A Max kVA Import Rate A MaxkVAImp'
14 Rate B Max kVA Import Rate B MaxkVAImp'
15 Rate C Max kVA Import Rate C MaxkVAImp'
16 Rate D Max kVA Import Rate D MaxkVAImp'
17 Cum.kWh Export CUM. kWh Exp'
18 Rate A kWh Export Rate A kWh Exp'
19 Rate B kWh Export Rate B kWh Exp'
20 Rate C kWh Export Rate C kWh Exp'
21 Rate D kWh Export Rate D kWh Exp'
22 Cum.kVArh Export Lag CUM kVArh Exp Lg'
23 Cum.kVArh Export Lead CUM kVArh Exp Lg'

Page 1 of 3 Display Parameters list


Wallaby Metering Systems Pvt. Ltd. 

24 Cum.kVAh Export CUM kVArh Exp Lg'


25 Average Power Factor Export Avg PF export'
26 Rate A Max kVA Export Rate A MaxkVAExp'
27 Rate B Max kVA Export Rate B MaxkVAExp'
28 Rate C Max kVA Export Rate C MaxkVAExp'
29 Rate D Max kVA Export Rate D MaxkVAExp'
30 Last Block avg Frequency Pre blk Avg Frq'
31 Last block net kWh transmitted with +/_ signPre blk Net kWh'
32 Net KVArh High Net KVArh high'
33 Net KVArh Low Net KVArh Low'
Voltage A Voltage B Voltage C
34 ABC V + ABC A'
Current A Current B Current C
35 Instantaneous PF Inst PF'
36 Demand Reset Count MDReset Count'
37 Instantaneous frequency Inst Freq'
Mode B- On Demand Display
38 Cumulative meter OFF duration Tot Powerofftime'
39 Inst.average Percent Voltage Inst Avg % Volt'
40 Inst.Active power with Sign Inst kW'
41 Inst.Reactive power with Sign Inst KVAr'
42 Inst. Apparent Power with Sign Inst KVA'
43 Last Reset Rate A Max kVA Import H1 Rate A MD Imp'
44 Last Reset Rate B Max kVA Import H1 Rate B MD Imp'
45 Last Reset Rate C Max kVA Import H1 Rate C MD Imp'
46 Last Reset Rate D Max kVA Import H1 Rate D MD Imp'
47 Last Reset Rate A Max kVA Export H1 Rate A MD Exp'
48 Last Reset Rate B Max kVA Export H1 Rate B MD Exp'
49 Last Reset Rate C Max kVA Export H1 Rate C MD Exp'
50 Last Reset Rate D Max kVA Export H1 Rate D MD Exp'
51 Last Reset Date & Time MD rst Date'
52 Cumulative Tamper Count Cum Tamper Count'
53 Last Tamper occurrence with date and Time Last Tamper Occ'

Page 2 of 3 Display Parameters list


Wallaby Metering Systems Pvt. Ltd. 

54 Last Tamper Restoration with date and Time Last Tamper Res'
MODE C- Test Mode Display
55 High Resolution total kWh Import CUMkWh imp '
56 High Resolution total kVArh Import Lag CUMKVarh implag'
57 High Resolution total kVArh Import Lead CUMkVarh impld'
58 High Resolution total kVAh Import Lag CUMkVAh imp'
Rising Demand Import kVA with Elapsed
59 RD Imp kVA'
Time(Simultaneously Displayed)
60 High Resolution total kWh Export CUMkWh exp '
61 High Resolution total kVArh Export Lag CUMkVarh explg'
62 High Resolution total kVArh Export Lead CUMkVarh expld'
63 High Resolution total kVAh Export Lag CUMkVAh exp '
Rising Demand Export kVA with Elapsed
64 RD Exp kVA'
Time(Simultaneously Displayed)

Display Cyclic Time - 10sec

Number Of Display Characters – 16 * 2 Row

High Resolution – 8* 4 (xxxxxxxx.xxxx)

Page 3 of 3 Display Parameters list