Failure Mode and Effect Analysis of Centrifugal Pump
Failure Mode and Effect Analysis of Centrifugal Pump
Failure Mode and Effect Analysis of Centrifugal Pump
Action Results
Potential Potential Current
Process Potential RPN S O D R
Component Failure Effect(s) of Sev Occ Process Det RPN Recommended Action(s)
Function Cause(s) Rank Actions Taken (if) e c e P
Mode Failure Controls
v c t N
Velocity variation at
Eventual Shaft
points around the Daily inspection, Have spare parts and check for Shaft monitored for sound and
Shaft deflection and pump 8 3 7 168 1 2 3 2 12
impeller -> High excess vibrations felt sound and excess vibrations vibration, replaced if needed
Failure
Transmit radial load
Shaft torque/input
power
Shaft maintained through
Cleaning, lubrication and spare
Excessive wear Shaft damage 8 Fretting Corrosion 3 Daily inspection 6 144 2 cleaning and lubrication, 2 3 2 12
parts availability
replaced if needed
Accumulation of
Clogging of Reduced pump Overhead tank fills Install a pressure gauge at Pressure gauge installed at
5 small debris or 4 5 100 7 3 2 1 6
impeller performance slowly outlet, perform maintenance outlet, impeller blades cleaned
contaminants
Increase fluid
Impeller
pressure
Impeller used to it's service life
Crack formation Impeller Breaks 9 Fatigue 2 N/A 7 126 4 yearly maintenance, spare part 2 1 6 12
and replaced when needed
Support shaft
weight/ matain Eventual Shaft Use vibration and sound
Daily inspection, Shaft aligned, condition
Bearing alignment of rotor Mis-alignment and Pump 7 Shaft unbalance 4 5 140 3 measuring devices, check shaft 2 2 2 8
excess vibrations felt monitored
with stationary Failure for alignment
parts
Provide a rotating
Motor Stator magnetic field to
drive armature Winding Motor windings are checked
Check motor windings, use
Failure/ Pump failure 8 Voltage surges 2 Daily inspection 3 48 12 and added if needed or 3 2 2 12
stabilizer
Shortage replaced
Produces phase
difference
Capacitor
between current in Pump fails to
Capacitor Capacitor fails 8 Overheating 3 temperature 2 48 12 Replace the capacitor Capacitor replaced 3 3 2 18
primary and main start
increases.
winding to start
motor
Total
1443