Design of Rectangular Underground Water Tank: S S M C+ SST
Design of Rectangular Underground Water Tank: S S M C+ SST
Design of Rectangular Underground Water Tank: S S M C+ SST
1. Design Constants :
For HYSD bars , Concrete M = 20
sst = 230 N/mm2 sin 36 = 0.587
wt. of concrete = 25 KN/m3
scbc = 7 N/mm2
m*c 13 x 7 =
k= = 0.283
m*c+sst 13 x 7 + 230
j= 1-k/3 = 1 - 0.283 / 3 = 0.906
R= 0.5.c. j .k = 3.5 x 0.906 x 0.283 = 0.897
9920.00 x 1000
Required depth = = 105 mm = 120 mm
0.897 x 1000
Provide total depth D = 120 + 50 = 170 mm
so that available d = 120 mm
2.2 Reinforcement details for long walls :
2.2.1. Vertical Reinforcemnet
a. Ast for outer face of wall ( Max B.M. on outer face )
Mf 9.92 x 1000000
Ast for B.M. = = = 397 mm2
sst.j.d 230 x 0.906 x 120
Using 12 mm bars , A = 3.14xdia 2
3.14 x 144
= 113 mm2
4 x100 4 x 100
Spacing of Bars = 1000 x 113 / 397 = 285 = 250 mm
Actual Ast for B.M. = 452.2 mm2
Hence Provided 12 mm F bar, @ 250 mm c/c.
b. Ast for inner face of wall ( Max B.M. on inner face )
Mf 4.59 x 1000000
Ast for B.M. = = = 183 mm2
sst.j.d 230 x 0.906 x 120
Using 12 mm bars , A = 3.14xdia 2
3.14 x 144
= 113 mm2
4 x100 4 x 100
Spacing of Bars = 1000 x 113 / 183 = 618 = 300 mm
(3d or 300 mm whichever is lesser)
Actual Ast for B.M. = 376.8 mm2
Hence Provided 12 mm F bar, @ 300 mm c/c.
2.2.2. Horizontal Reinforcemnet
c. Ast for Secondary reinforcement (min)
0.20 % of nominal reinforcement
0.20 x 1000 x 170
Area of steel = = 340 mm2
100
Using 10 mm bars , A = 3.14xdia2 3.14 x 100
= 79 mm2
4 x100 4 x 100
Spacing of Bars = 1000 x 79 / 340 = 231 = 220 mm
Actual Ast for B.M. = 356.8 mm2
Hence Provided 10 mm F bar, @ 220 mm c/c in both direction
12400.00 x 1000
Required depth = = 118 mm < 120 mm OK
0.897 x 1000
Provide total depth D = 120 + 50 = 170 mm
so that available d = 120 mm
3.2 Reinforcement details for short walls :
3.2.1. Vertical Reinforcemnet
a. Ast for outer face of wall ( Max B.M. on outer face )
Mf 12.40 x 1000000
Ast for B.M. = = = 496 mm2
sst.j.d 230 x 0.906 x 120
Using 12 mm bars , A = 3.14xdia2 3.14 x 144
= 113 mm2
4 x100 4 x 100
Spacing of Bars = 1000 x 113 / 496 = 228 = 220 mm
Actual Ast for B.M. = 513.8 mm2
Hence Provided 12 mm F bar, @ 220 mm c/c.
b. Ast for inner face of wall ( Max B.M. on inner face )
Mf 6.20 x 1000000
Ast for B.M. = = = 248 mm2
sst.j.d 230 x 0.906 x 120
Using 12 mm bars , A = 3.14xdia2 3.14 x 144
= 113 mm2
4 x100 4 x 100
Spacing of Bars = 1000 x 113 / 248 = 456 = 300 mm
(3d or 300 mm whichever is lesser)
Actual Ast for B.M. = 376.8 mm2
Hence Provided 12 mm F bar, @ 300 mm c/c.
3.2.2. Horizontal Reinforcemnet
c. Ast for Secondary reinforcement (min)
0.20 % of nominal reinforcement
0.20 x 1000 x 170
Area of steel = = 340 mm2
100
Using 10 mm bars , A = 3.14xdia2 3.14 x 100
= 79 mm2
4 x100 4 x 100
Spacing of Bars = 1000 x 79 / 340 = 231 = 220 mm
Actual Ast for B.M. = 356.8 mm2
Hence Provided 10 mm F bar, @ 220 mm c/c in both direction