GAS FLOW CALCULATION

AGA - 3 BASE ON L-10 CHART

Meter : Date :
Service : -
Location :

Flange Taps : ( 1 ) Up Stream ( 2 ) Down Stream 1 Up Stream

INPUT DATA :
D [inch] Meter Tube Diameter 5.700000
d [inch] Orifice Diameter 3.000000
Range
Hu Differential reading on L-10 chart 200 In H2O 5.900000
Pu Static Pressure Reading on L-10 chart 1500 Psi 7.350000
Tu Temperature Reading on L-10 chart 200 o
F 5.154000
Mc [%] Mol Percent of CO2 Content 7.678000
Mn [%] Mol Percent of N2 Content 0.264000
SG Specific Gravity 0.680000
k Specific Heat Ratio , Cp/Cv 1.300000
Pb [PsiA] Pressure Base 14.650000
Tb [ºR] Temperature Base 520.000000
Duration [Hour] Time Duration 24.000000
[Minute] 0.000000

CALCULATION :
Hw [inch H2O] Differential Pressure 69.620000
Pf [PsiA] Absolute Static Pressure 824.987500
Tf [ºR] Absolute Temperature 513.127432
b Beta Ratio 0.526316
Ke Empirical Equation for K 0.630902
K1 0.630902
K2 0.000000
K3 0.000000
K4 0.000000
Ko Flow Coefficien when Rd is infinite 0.628065
E Value for E determination 903.462770
B Value for B determination 221.992571
Fb Basic Orifice Factors 1,911.533422
Y1 Expansion Factors for Upstream 0.998976
Y2 Expansion Factors for Downstream 1.000500
b Value for Fr determination 0.037190
Fr "b" Values for Reynold Number Factors. 1.000155
Fpb Pressure Base Factors. 1.005461
Ftb Temperature Base Factors. 1.000635
Ftf Flowing Temperature Factors. 1.006355
Fgr Specific Gravity Factors. 1.212678
Fa Orifice Thermal Expansion Factors (mat. SS304,316) 0.999725
Fpv Supercompressibility Factors. 1.079497
Padj Adjusted Pressure 827.882049
Tadj Adjusted Temperature 44.677206
l Value for Fpv determination 0.842582
t Value for Fpv determination 1.009354
m Value for Fpv determination 0.026307
n Value for Fpv determination 6.578801
B Value for Fpv determination 11.074039
E2 Value for Fpv determination 0.999043
b Value for Fpv determination 25.301280
D Value for Fpv determination 4.121337

C' Orifice Flow Constant 2,530.718583


Q [scf/hr] Flow Rate in cubic feet per hour at base conditions 606,505.226421
Q [M scfd] Flow Rate in M scfd at base conditions 14,556.1254
Q [M scf] Total Gas Measured in M cubic feet at base condition 14,556.1254

Approved By, Prepared By,