Calculation of Column C4
Calculation of Column C4
Calculation of Column C4
General Data
Column No. : C4
Level : Base to Ground
Design Code = IS 456 + IS 13920 - 2016
Grade Of Concrete = M25 N/sqmm
Grade Of Steel = Fe500 N/sqmm
Column B = 750 mm
Column D = 750 mm
Clear Floor Height @ B = 1350 mm
Clear Floor Height @ D = 1350 mm
No Of Floors = 1
No Of Columns In Group = 1
Column Type : UnBraced
Minimum eccentricity check : One Axis at a Time
Code defined D/B ratio : 4
D/B Ratio : 1 <= 4 Hence, Design as
Column
Load Data
Analysis Reference No. = 10
[55] : 1.5 ( DL) +1.5 ( EQX+)
Load Combination = +(TEMP(-17.7))
Pu = 1352.99 kN
Mux = 485.25 kNm
Muy = 3.1 kNm
Vux = 45.09 kN
Vuy = 247.7 kN
Column
Joint Beta
Stiffness
Beam 1 Beam 2
(Length (Length
Beam 1 Beam 2
x Width x x Width x
Depth) Depth)
N/m mm mm N/m N/m
Bottom 1255.58 No Beam No Beam - - 1
6750 x 350 x
Top 1255.58 No Beam 182.292 - 0.949
750
Sway Condition (as per Stability
Index) = Sway
Effective Length Factor
along Minor axis = 1.2
Slenderness Check
Max Slenderness Ratio(L/B) = 1.8
< 60 (Hence Ok)
Column Is Unbraced Along
D Slenderness Check Along
D:
Effective Length Factor = 1.2
Slenderness Ratio = Effective Length / D
2.16, Column not Slender
= Along D
Column Is Unbraced Along B
Slenderness Check Along B:
Effective Length Factor = 1.2
Slenderness Ratio = Effective Length / B
2.16, Column not Slender Along B
=
Calculation of Design Moment
Mslndx Mdesign-
Direction Manalysis Mmin (Abs) Mdesign
(Abs) final
A B C E F
Major Axis - Mux 485.25 --- 485.25 0 485.25
Minor Axis - Muy 3.1 37.48 37.48 0 37.48
Where
A = Moments directly from analysis
B = Moments due to minimum eccentricity
C = Maximum of analysis moment and min. eccentricity = Max
(A,B) E = Moment due to slenderness effect
F = Final design Moment = Max(C- Top Bottom , D- Top Bottom) + E
Pu = 1352.99 kN
Mux = 485.25 kNm
Muy = 37.48 kNm
Design Of Shear
Shear Calculation from Beam
Capacity
Along D:
Height of column above level
= 2250 mm
considered (hst1)
Height of column below
= 675 mm
level considered (hst2)
Height (hst) = 3675 mm
Along B:
Height of column above level
considered (hst1) = 2250 mm
Height of column below
level considered (hst2) = 675 mm
Height (hst) = 3675 mm
Beam Beam Torsio Moment Capacity Beam Moment Capacity Beam Resultant Moment
Size angle n @ Top @ Bottom
w.r.t. mome
colum nt
n Ly
Ast Mu Ast Mu Top Top Bot Bot
Mu Ast req Mu Ast req
pro cap pro cap Ly Lx Ly Lx
(kNm (sqmm (kNm (sqmm
(mm) (deg) (kNm) (sqmm (kNm (sqm (kNm (kNm (kNm (kNm (kNm
) ) ) )
) ) m) ) ) ) ) )
350x75 606.3 2453.1 2513.2 644.8 474.9 1855.6 506.8 644.8 506.8
180 0 2010.6 0 0
0 1 5 8 4 9 8 3 4 3
350x75 502.1 1987.1 506.8 285.2 1031.5 334.4 506.8 334.4
270 0 2010.6 1231.5 0 0
0 2 8 3 9 7 1 3 1
= 193.08
= 1.0086
= 1.5
= 1 + 3 x Pu / ( B x D x = 1.0086
Enhanced shear strength, Tc-e = 0.706 N/sqmm
Design shear check = Tvy < Tc x Enhancement factor
Link for Shear Design along D are not
required
= 1.0086
Shear Strength Enhancement
Factor (max) = 1.5
Shear Strength Enhancement
Factor = 1.0086
Enhanced shear strength, Tc-e = 0.706 N/sqmm
Design shear check = Tvx < Tc x Enhancement factor
Link for Shear Design along B are not
required
Design Of Links
Links in the zone where special confining links are not required
Normal Links
Diameter of link =8 mm
> Max. longitudinal bar dia / 4
=8 mm
Criterion for spacing of normal
links
Min. Longitudinal Bar dia X 16 = 400 mm
Min. dimension of column = 750 mm
Max. 300 mm = 300 mm
Least lateral edge dimension/2 = 375
= 41.62 sqmm
Area of special confining
link, Ash = Maximum (Ash1,Ash2)
= 41.62 sqmm
Diameter of special confining link = 8 mm
= > Max. longitudinal bar dia / 4
=8 mm
Zone for special confining links -
criterion
Max. Size of column,D = 750 mm
Clear height/6 = 225 mm
Minimum value = 450 mm
: No
Consider Capacity Design Consider
Overburden
: Yes
Pressure
No. of Piles = 4
Pile Diameter = 600 mm
Pilecap Offset = 150 mm
Pile Spacing = 2.5 xØ
Alternate Pile Spacing = 2.5 xØ
Pilecap Size = 2400 X 2400 mm
Pilecap Depth = 750 mm
Soil Wt. + Pile-cap Wt. = 444.96 kN
Check for Maximum Load on One Pile:
Critical Analysis Load : 1101
Combination
Critical Load Combination : [10] : (LOAD 6: PO) +(LOAD 4: EO) +(LOAD 1: DL) +
(LOAD 2: LL) +(LOAD 18: TEMP (+13.3))
Pcomb = 3023.98 kN
Ptotal = Pcomb + Soil Wt. + Pilecap Wt.
= 3468.94 kN
Mx = 28.72 kNm
My = -16.81 kNm
P = Ptotal/ No. of Piles
= 867.24 kN
Pmx = 9.57 kN
Pmy = 5.6 kN
= 3872 kN
Check for Maximum shear on Pile Group:
Critical Analysis Load : 2119
Combination
Critical Load Combination : [27] : (LOAD 6: PO) +(LOAD 4: EO) +(LOAD 1: DL) +0.8
(LOAD 2: LL) +0.8 (LOAD 14: -WLZ-0.2) +(LOAD 19: TEMP(-
17.7))
Pcomb = 2889.16 kN
Ptotal = Pcomb + Soil Wt. + Pilecap Wt.
= 3334.12 kN
Mx = 28.72 kNm
My = -17.46 kNm
Vx = 47.22 kNm
Vy = 45.6 kNm
Maximum shear on pile
group = sqrt(47.222 + 45.62)
= 65.65 kN
Shear capacity of pile group 4 x 60 x 1 x
= 1
= 240 kN
Check for Uplift Load on
Pile:
No uplift in any pile
Design for Bending:
Bottom Reinforcement Along Column-D
Critical Analysis Load : 4501
Combination
Critical Load Combination : [155] : 1.5 (LOAD 4: EO) +1.5 (LOAD 1: DL) +1.5 (LOAD 6: PO)
+1.5 (LOAD 2: LL) +1.5 (LOAD 18: TEMP (+13.3))
Pcomb = 4535.97 kN
Ptotal = Pcomb + Soil Wt. + Pilecap Wt.
= 5203.41 kN
Mx = 43.07 kNm
My = -25.21 kNm
Ppile = Max Load on pile
= 1323.62 kN
Deff = 690 mm
Beff = 900 mm
DfCol = 0.38 m
BMux = Ppile X DfCol
= 496.36 kNm
PtReq = 0.28 %
AstReq (BM) = 1947.97 sqmm/m
AstPrv = T25 @ 250 C/C
= 2011 sqmm/m
= 462 sqmm/m
Design for One Way
Shear: Along Column-D
Critical Analysis Load : 4501
Combination
Critical Load Combination : [155] : 1.5 (LOAD 4: EO) +1.5 (LOAD 1: DL) +1.5 (LOAD 6: PO)
+1.5 (LOAD 2: LL) +1.5 (LOAD 18: TEMP (+13.3))
Pcomb = 4535.97 kN
Ptotal = Pcomb + Soil Wt. + Pilecap Wt.
= 5203.41 kN
Mx = 43.07 kNm
My = -25.21 kNm
Ppile = Max Load on pile
= 1323.615 kN
Location of critical section is at d/2 from face of column
Section Location from
column center = 720 mm
Data for Piles
Pile No Load (kN) % covered Shear (kN)
P1 1294.9 45 712.19
P2 1323.62 45 727.99
P3 1278.09 45 702.95
P4 1306.81 45 718.74
Along Column-B
Critical Analysis Load
: 4501
Combination
Critical Load Combination : [155] : 1.5 (LOAD 4: EO) +1.5 (LOAD 1: DL) +1.5 (LOAD 6: PO)
+1.5 (LOAD 2: LL) +1.5 (LOAD 18: TEMP (+13.3))
Pcomb = 4535.97 kN
Ptotal = Pcomb + Soil Wt. + Pilecap Wt.
= 5203.41 kN
Mx = 43.07 kNm
My = -25.21 kNm
Ppile = Max Load on pile
= 1323.615 kN
Location of critical section is at d/2 from face of column
Section Location from
column center = 710 mm
Data for Piles
Pile No Load (kN) % covered Shear (kN)
P1 1294.9 43.33 733.78
P2 1323.62 43.33 750.05
P3 1278.09 43.33 724.25
P4 1306.81 43.33 740.52