Catalog Numbering Guide For EFDB/EFD, N1/N2, and Contender Control Stations

Download as pdf or txt
Download as pdf or txt
You are on page 1of 22

M- 2

Catalog Numbering Guide for EFDB/EFD,


N1/N2, and Contender® Control Stations

Catalog Numbering Guide for EFD/EFDB Control Stations

EFDC T 10 J1U2 JGBG SNPTESTQ U2 SR SNPRUNQ

BACKBOX/HUB HUB SIZE: OPTIONS FOR


ARRANGEMENT: DEVICE FOR SPECIAL
50 - 1/2” FIRST GANG
EFD - Dead-End SECOND GANG NAMEPLATE FOR
75 - 3/4” - SEE TABLE
EFDC - Feed-Thru - SEE TABLE, SECOND GANG
10 - 1” PAGES M-3,M-4
EFK - Cover PAGES M-3 - SEE TABLE,
Only PAGE M-4
BOX TYPE:
Blank - 2 Gang DEVICE FOR
B - Single Gang FIRST GANG OPTIONS FOR
SPECIAL
or Cover Only - SEE TABLE, SECOND GANG
NAMEPLATE FOR
L - 3-Device PAGES M-3 - SEE TABLE,
FIRST GANG -
T - Tandem # OF GANGS: SEE TABLE PAGES M-3,M-4
1 - Single Gang
PAGE M-4
2 - Two Gang
Blank - Tandem, Cover Only
or 3-Device
Refer to pages M-7 through M-25 for complete details.

Catalog Numbering Guide for N1/N2 Control Stations

N2D C 75 102 SRC SLNPFORNQ

SERIES: HUB ARRANGEMENT: HUB SIZE: DEVICE -


N1D - Cover and Box OPTIONS - SEE SPECIAL
Blank - Dead-End or 75 - 3/4” SEE TABLE, TABLE, PAGES NAMEPLATE
N2D - Cover and Box Cover Only Blank - Cover Only PAGES M-3
N1K - Cover Only M-3,M-4 - SEE TABLE,
C - Feed-Thru PAGE M-4
N2K - Cover Only

Refer to pages M-49 through M-60 for complete details.

Catalog Numbering Guide for Contender® Control Stations

EDS C 2 1 524 J3 LNPUPQ 1274 S634 SLNPJORQ

SERIES HUB OPTIONS FOR DEVICE FOR SPECIAL


SIZE: FIRST GANG SECOND GANG NAMEPLATE FOR
1 - 1/2” - SEE TABLE - SEE TABLE, SECOND GANG
2 - 3/4” PAGES M-3,M-4 PAGES M-3 - SEE TABLE,
3 - 1” PAGE M-4
C - Feed Thru DEVICE FOR SPECIAL OPTIONS FOR
M

Blank - Dead End or FIRST GANG NAMEPLATE FOR SECOND GANG


Cover Only - SEE TABLE, FIRST GANG- - SEE TABLE,
PAGES M-3 SEE TABLE, PAGES M-3,M-4
PAGE M-4
BOX TYPE:
2 - Two Gang
Blank - 1 Gang
T - Tandem
L - Three Device
K - Cover Only

Refer to pages M-26 through M-38 for complete details.

Effective September, 2005 800-621-1506


Copyright 2005 www.appletonelec.com
PAGE 2
M-3
Catalog Numbering Guide Descriptions
for EFDB/EFD, N1/N2, and Contender® Control Stations.

Available in
EFD & N1 & N2 Contender Available in
DEVICE DESCRIPTION 1-G, 2-G*
Suffix Suffix Three Device
Tandem
One Pilot Light (Red Standard) J1 524 Y
Two Pilot Lights J2 561 Y
One Pilot Light & One Momentary P.B. J1U1 473 Y
One Pilot Light & Two Momentary P.B.’s J1U2 234 Y Y
One Pilot Light & One Maintained P.B. J1UM1 701 Y
One Pilot Light & One Dust-Cap P.B. J1DU1 702 Y
One Pilot Light & One 12 Selector Switch * J112 703 Y
One Pilot Light & One 35 Selector Switch * J135 704 Y
One Pilot Light & One 102 Selector Switch * J1102 705 Y
One Pilot Light & One 345 Selector Switch * J1345 706 Y
One Monetary P.B. U1 84 Y
Two Monetary P.B.’s U2 90 Y
Two Side-By-Side Momentary P.B.’s U2DBL 195 Y
Three Monetary P.B.’s U3 707 Y Y
One Momentary P.B. & One Maintained P.B. U1UM1 708 Y
One Momentary P.B. & One Dust-Cap P.B. U1DU1 709 Y
One Momentary P.B. & One 12 Selector Switch * U112 710 Y
One Momentary P.B. & One 35 Selector Switch * U135 711 Y
One Momentary P.B. & One 102 Selector Switch * U1102 712 Y
One Momentary P.B. & One 345 Selector Switch * U1345 713 Y
One Maintained P.B. (Mushroom Head - Red) UM1 714 Y
Two Maintained P.B. UM2 715 Y
One Maintained & One Dust-Cap P.B. UM1DU1 716 Y
One Maintained P.B. & One 12-Selector Switch * UM112 717 Y
One Maintained P.B. & One 35-Selector Switch * UM135 718 Y
One Maintained P.B. & One 102-Selector Switch * UM1102 719 Y
One Maintained P.B. & One 345 Selector Switch * UM1345 720 Y
One Dust Cap P.B. DU1 721 Y
Two Dust Cap P.B.’s DU2 722 Y
One Dust Cap & One 12 Selector Switch * DU112 723 Y
One Dust Cap & One 35 Selector Switch * DU135 724 Y
One Dust Cap & One 102 Selector Switch * DU1102 725 Y
One Dust Cap & One 345 Selector Switch * DU1345 726 Y
One 12-Selector Switch * 12 271 Y
One 35-Selector Switch * 35 272 Y
One 102-Selector Switch * 102 273 Y
One 345-Selector Switch * 345 274 Y
120VAC Photocell PC120 727 Y
277VAC Photocell PC277 728 Y
M

Three Dust Cap P.B.’s DU3 729 Y


One Momentary and Two Maintained P.B.’s U1UM2 730 Y
Two Momentary and One Maintained P.B.’s U2UM1 731 Y Y
Three Maintained P.B.’s UM3 732 Y
Three Pilot Lights J3 476 Y
Two Pilot Lights and One Momentary P.B. J2U1 733 Y
One Pilot Light and Two Dust Cap P.B.’s J1DU2 734 Y
Two Pilot Lights and One Dust Cap P.B. J2DU1 735 Y
One Pilot Light and Two Maintained P.B.’s J1UM2 736 Y
Two Pilor Lights and One Maintained P.B. J2UM1 737 Y

Effective September, 2008 800-621-1506


Copyright 2008 www.appletonelec.com
PAGE 3
M-4
Catalog Numbering Guide Descriptions
for EFDB/EFD, N1/N2, and Contender® Control Stations.

EFD & N1 & Contender Pilot Light (continued)


Options Description
N2 Suffix Suffix TEST LNPTESTQ
Momentary P.B. Securing Rod SR S153 LOW LNPLOWQ
Selector Switch Lockout LD S349 HIGH LNPHIGHQ
Spring Return From Right Selector Two-Position Selection Switch Nameplates
SRC S634
Switch (3 Positions Only) FORWARD-REVERSE SLNPFRQ
Spring Return From Left Selector Switch HAND-AUTO**† SLNPHAQ
SLC S635
(3 Positions Only)
ON-OFF SLNPOO
Alternate Contacts Selector Switch ALT S636
START-STOP SLNPSS
Change One Red Lens to Green Lens JGBG J3
BLANK SLNPBQ
Change One Red Lens to Opal Lens JGBO J8
UP-DOWN SLNPUDQ
Change One Red Lens to Amber Lens JGBA J6
RUN-JOG SLNPRJQ
Change One Red Lens to Blue Lens JGBB J11
AUTO-HAND SLNPAHQ
Change One Red Lens to Clear Lens JGBC J10
OFF-REMOTE SLNPORQ
Add 220 / 120 V Transformer (J1 Device Only) TR2 S801
Three-Position Selection Switch Nameplates
Add 220 / 120 V Transformer (J1 Device Only) TR3 S802
FORWARD-OFF-REVERSE SLNPFORQ
Add 220 / 120 V Transformer (J1 Device Only) TR4 S803
HAND-OFF-AUTO**† SLNPHOAQ
Add 220 / 120 V Transformer (J1 Device Only) TR5 S804
RUN-OFF-JOG SLNPROJQ
Change One Red Pilot to Red LED LEDR LED1
BLANK SLNPB3
Change One Red Lens to Green LED LEDG LED3
REVERSE-OFF-FORWARD SLNPROFQ
Change One Red Lens to Amber LED LEDA LED6
AUTO-OFF-HAND SLNPAOHQ
Add Red Mushroom Head to Momentary P.B. NMRBRE S805
HAND-OFF-REMOTE SLNPHORQ
Add Black Mushroom Head to Momentary P.B. NMRBBL S806
1-OFF-2 SLNP102Q
Add Green Mushroom Head to Momentary P.B. NMRBGR S807
JOG-OFF-RUN SLNPJORQ
Locking Guard for Maintained P.B. SMPBLG S808
STOP-RUN-START SLNPSRSQ
LOCAL-OFF-REMOTE SLNPLORQ
Nameplates * Mementary Pushbuttons
Mushroom Head Pushbuttons (Maintained and Momentary) For Rectangular Weatherboot Style Only (Not for round weatherboot style)

START MNPSTQ BLANK** SNPBQ


STOP MNPSPQ FORWARD SNPFWDQ
EMERGENCY STOP MNPESTPQ JOG SNPJOGQ
BLANK MNPBQ RUN SNPRUNQ
Pilot Light STOP** SNPSPQ
START** SNPSTQ
BLANK LNPBQ
DOWN SNPDOWNQ
FORWARD LNPFWDQ
FAST SNPFASTQ
JOG LNPJOGQ
SLOW SNPSLOWQ
RUN LNPRUNQ
RAISE SNPRAISEQ
STOP LNPSPQ
LOWER SNPLOWERQ
START LNPSTQ
RESET SNPRESETQ
DOWN LNPDOWNQ
OFF SNPOFFQ
FAST LNPFASTQ
M

ON SNPONQ
SLOW LNPSLOWQ
RAISE LNPRAISEQ REVERSE SNPREVQ
LOWER LNPLOWERQ OPEN
RESET LNPRESETQ CLOSE SNPCLOSEQ
OFF LNPOFFQ UP SNPOPENQ
ON LNPONQ TEST SNPTESTQ
REVERSE LNPREVQ LOW SNPLOWQ
CLOSE LNPCLOSEQ HIGH SNPHIGHQ
* No custom nameplates available
OPEN LNPOPENQ **Included as standard (no need to use suffix)
UP LNPUPQ † Standard on maintained 2 and 3 position selector switches

Effective September, 2008 800-621-1506


Copyright 2008 www.appletonelec.com
PAGE 4
M- 7
Factory Sealed Control Stations and
Pilot Lights: EFDB/EFD and EDS Series
Explosionproof, Dust- Ignitionproof
UNILETS® for use with Threaded Metal Conduit.

Applications
• Push buttons and selector switches
are used in conjunction with contactors
or magnetic starters for remote control
of motors. They provide circuit control
and/or selection.
• Pilot lights provide visual assurance
that an electrical function is being
perfor med at a remote or local
location.
• EFD/EFDB and EDS factory sealed
EFDB Photocontrol
control stations confine arcing of device
within the enclosure, preventing ignition
of ignitable atmospheres during control EFD Combination Pilot
operation of motors and other equipment. Light and Push Buttons

• Used in classified areas where


flammable vapors, gases or highly
combustible dusts are present.
• For installation in chemical and
petrochemical plants, refineries, and
other process industries.
Features: EFD/EFDB Factory Sealed Push
Buttons and Selector Switches
• Eliminate need for adding sealing EDS Rocker Arm
fittings and compound at each conduit Push Button
entrance.
• Heavy-duty, 10 ampere 600V rated.
• Dozens of possible combinations of
push buttons, pilot lights and selector
switches.
• Smooth, rounded integral bushing in
each EFD/EFDB hub protects conductor
insulation.
• Accurately tapped, tapered hubs for
tight, rigid joints and ground continuity.
• Stainless steel push button shaft
operates within stainless steel bushing
assuring long, maintenance-free operation. EFDB Pilot Light
• Push button and selector switch
contacts are silver cadmium oxide which
are “sealed” in lower phenolic cham- • All EFD/EFDB front-operated push • Models also available in combination
ber isolated from corrosive elements. buttons are suppled with lockout type with factory sealed push buttons and
Assures positive contact and long, guards as standard. Hole in guard selector switches.
M

trouble-free operation. will accept locks with up to 1/4” hasp.


Features: EFD/EFDB
Permits locking of push button to
• Enclosed stainless steel helper spring
prevent unauthorized operation.
Selector Switches
prevents accidental operation of push
button in severe vibration installations. • Clearly marked terminals with brass • Factory sealed selector switch-
es furnished with nylon cam-oper-
screws assure quick, easy wiring.
• Push button models also available ated, heavy-duty push buttons for
either two-position or three-position
with Dust Cap for use in areas where Features: EFD/EFDB Pilot Lights
excessive dust, moisture or corrosive • Factory sealed pilot lights supplied maintained contact operation.
conditions are encountered. with red jewel/guard assembly and • High thermal and arc resistance,
• Corrosion-resistant captive stainless 120V, 6W type 6S6 lamp. high dielectric strength.
steel hex-head cap screws hold EFKB
covers to body.
Effective September, 2005 800-621-1506
Copyright 2005 www.appletonelec.com
PAGE 7
M- 8 Factory Sealed Control Stations and
Pilot Lights: EFDB/EFD and EDS Series
Explosionproof, Dust- Ignitionproof
UNILETS® for use with Threaded Metal Conduit.

Features: EDS Push Buttons • Three position selector switches with


• Factory sealed—eliminates need for modified operation. Momentary contact
left position, spring return to center,
adding sealing fittings and compound
at each conduit entrance. maintained contact right position. Add
suffix —SLC.
• Heavy duty, 10 ampere 600V rated.
• Alternate contacts add suffix —ALT.
• Switch is enclosed in separate
• EFD/EFDB selector switch Lockout—
sealing chamber.
locks two- or three-position handle in
• Sealing chamber has smooth, double
any position. Suffix —LD.
flanges that mate both to cover and mount-
ing enclosure to provide flame-tight joints. • Push button front operated mush- EDS factory sealed rocker arm push but-
ton control station—shows separate seal-
room head (momentary contact): In red,
• Pigtail leads from push buttons are
add suffix —NMRBRE; In green, add
ing chamber and device construction.
factory sealed in sealing well. Rocker arm has holes for lock.
suffix —NMRBGR; In black, add suffix
• Stainless steel hex-head screws —NMRBBL. Securing Rod for EFD/
attach sealing chamber to cover and
mounting enclosure.
• EFD/EFDB pilot light jewel/guard EFDB Push Button
Lockout Guard—avail-
assembly. Order by suffixes if color
• Side rocker arm push button has desired is other than red, as fol-
able as an optional
item as catalog number
lockout holes. lows: Amber, —JGBA; Blue, —JGBB; NBL-SR (single guard
• EFD/EFDB back box supplied with Clear —JGBC; Green, —JGBG; Opal, only) or add Suffix —SR
internal ground screw. —JGBO. For colored LED jewel/guard to push button catalog
Standard Materials assembly, order by suffixes: red —LEDR; number. Lockout Guard,
green —LEDG; amber —LEDA. furnished as standard
• EFDB control stations: malleable iron
• EFD/EFDB pilot light transformers for with the EFD/ EFDB
body with aluminum cover. push button, may also
single pilot light per gang. Order by suffix:
• SPBB push putton: aluminum upper
Primary Lamp
be padlocked.
barrel and phenolic lower barrel with
nylon plastic button (Dust Cap models Voltage Voltage Suffix
have neoprene buttons). 220 120 —TR-2
• SPLN/SPLS pilot light: aluminum 277 120 —TR-3
guard and body assembly; steel clamp- 440 120 —TR-4 SPBB factory
ing ring; and tempered glass jewel. sealed push button
550 120 —TR-5
• SSBA selector switch: aluminum
• EFD and EDS units may be supplied
used in EFD/EFDB
Series—standard
operator mechanism, nylon cam, and
with brazed hubs as 3, 4, and 5 gang type and unit with
sealed phenolic contact block. dust cap.
in a variety of hub configurations. See
• EDS control stations: malleable iron Ordering Information page for how to
body and cover; aluminum sealing cham- order these and other “custom” units by SPBB Design Features
ber; and nylon 6/6 operating handle. adding suffixes to mounting body catalog
Standard Finishes numbers.
• EFD/EFDB control stations: body, triple- • Securing Rod for EFD/EFDB Push
coat—(1) zinc electroplate, (2) dichro- Button Lockout Guard. Suffix —SR.
mate, and (3) epoxy powder coat. • For complete list of options, see Cat-
• SPBB push button, SPLN/SPLS alog Numbering Guide on Pages M-2
pilot light and SSBA selector switch: through M-4.
natural finish. Compliances

M

EDS control stations: body and cover,


triple-coat—(1) zinc electroplate, (2) di-
• UL Standard 698.
chromate, and (3) epoxy powder coat
• Class I, Div. 1 and 2; Class II, Div. 1 and
2. See listing pages for specific groups.
sealing chamber, natural finish.
• Appleton malleable iron products con-
Options form to ASTM A47-77, Grade 32510,
• Three position selector switches with which has the following properties: ten-
modified operation. Momentary contact sile strength, 50,000 psi; yield, 32,000
right position, spring return to center, psi; and elongation, 10%.
maintained contact left position. For
description and switch diagram see
• Appleton aluminum products are
produced from high strength copper-
page M-15. Add suffix —SRC. free (4/10 of 1% max.) alloy.
Effective September, 2005 800-621-1506
Copyright 2005 www.appletonelec.com
PAGE 8
Class I, Div. 1 and 2
M- 9
Groups B◊,C,D EFD/EFDB Factory Sealed
Class II, Div. 1 and 2 Push Button Stations:
Groups E,F,G
Class III Explosionproof, Dust- Ignitionproof
NEMA 3,7CD,9EFG UNILETS® for use with Threaded Metal Conduit.
10 Ampere, 600V A.C. Max. for Heavy Duty Use.
Furnished with Internal Ground Screw.
U.S. Pat. 3,699,276 Hub Size, Nameplate Catalog Number
Patented Canada 1974 Inches Description Marking Dead-End Feed-Thru

Single Gang*◊
Momentary Contact
1/2 1 Circuit Specify EFDB150-U1 EFDCB150-U1
3/4 Universal EFDB175-U1 EFDCB175-U1
1 EFDB110-U1 EFDCB110-U1

1/2 2 Circuits Specify EFDB150-U2 EFDCB150-U2


3/4 Universal EFDB175-U2 EFDCB175-U2
1 EFDB110-U2 EFDCB110-U2

Maintained Contact
1/2 1 Circuit EFDB150-UM1 EFDCB150-UM1
3/4 Universal EFDB175-UM1 EFDCB175-UM1
1 EFDB110-UM1 EFDCB110-UM1

Two Gang*
Momentary Contact
1/2 2 Circuits Specify EFD250-U1 EFDC250-U1
3/4 Universal EFD275-U1 EFDC275-U1
1 EFD210-U1 EFDC210-U1

1/2 4 Circuits Specify EFD250-U2 EFDC250-U2


3/4 Universal EFD275-U2 EFDC275-U2
1 EFD210-U2 EFDC210-U2

Three Device‡
Momentary Contact
M

1/2 3 Circuits Specify EFDL50-U3 EFDCL50-U3


3/4 Universal EFDL75-U3 EFDCL75-U3
1 EFDL10-U3 EFDCL10-U3

* Malleable iron body and aluminum cover. For aluminum body, add suffix —A.
‡ Aluminum body, not available.
◊ Shaded area indicates items suitable for Class I, Div. 1 and 2, Groups B, C and D; Class II, Groups E, F and G and Class III.
For Class I, Group B, external seals must be installed at each conduit entrance.
See page 16 for push button accessories and parts. Dimensions on pages 24 and 25.

Effective September, 2005 800-621-1506


Copyright 2005 www.appletonelec.com
PAGE 9
M- 10
Class I, Div. 1 and 2
Groups B◊,C,D EFD/EFDB Factory Sealed Combination
Class II, Div. 1 and 2 Push Button and Pilot Light Stations:
Groups E,F,G
Class III Explosionproof, Dust- Ignitionproof
NEMA 3,7CD,9EFG UNILETS® for use with Threaded Metal Conduit.
10 Ampere, 600V A.C. Max. for Heavy Duty Use.
Momentary Contact. Furnished with Internal Ground Screw.
U.S. Pat. 3,699,276 Hub Size, Nameplate Catalog Number
Patented Canada 1974 Inches Description Marking Dead-End Feed-Thru
Single Gang*◊

1/2 1 Circuit Specify EFDB150-J1U1 EFDCB150-J1U1


3/4 Universal EFDB175-J1U1 EFDCB175-J1U1
1 and 1 Pilot EFDB110-J1U1 EFDCB110-J1U1
Light

1/2 2 Circuits Specify EFDB150-J1U2 EFDCB150-J1U2


3/4 Universal EFDB175-J1U2 EFDCB175-J1U2
1 Circuit 2 Circuit 1 and 1 Pilot EFDB110-J1U2 EFDCB110-J1U2
1 Pilot Light 1 Pilot Light Light

Two Gang*

1/2 2 Circuits Specify EFD250-J1U2 EFDC250-J1U2


3/4 Universal EFD275-J1U2 EFDC275-J1U2
1 and 1 Pilot EFD210-J1U2 EFDC210-J1U2
Light

1/2 2 Circuits Specify EFD250-J2U2 EFDC250-J2U2


3/4 Universal EFD275-J2U2 EFDC275-J2U2
1 Pilot Light 2 Pilot Lights 1 and 2 Pilot EFD210-J2U2 EFDC210-J2U2
2 Circuit 2 Circuit Lights

Three Device‡

1/2 2 Circuits Specify EFDL50-J1U2 EFDCL50-J1U2


3/4 Universal EFDL75-J1U2 EFDCL75-J1U2
1 and 1 Pilot EFDL10-J1U2 EFDCL10-J1U2
Light

1/2 1 Circuit Specify EFDL50-J2U1 EFDCL50-J2U1


2 Circuit, 1 Circuit, 3/4 Universal EFDL75-J2U1 EFDCL75-J2U1
1 Pilot Light 2 Pilot Lights 1 and 2 Pilot EFDL10-J2U1 EFDCL10-J2U1
Lights

Two Gang Tandem‡


1/2 2 Circuits Specify EFDT50-J1U2 EFDCT50-J1U2
3/4 Universal EFDT75-J1U2 EFDCT75-J1U2
1 and 1 Pilot EFDT10-J1U2 EFDCT10-J1U2
Light
M

1/2 2 Circuits Specify EFDT50-J2U2 EFDCT50-J2U2


3/4 Universal EFDT75-J2U2 EFDCT75-J2U2
1 and 2 Pilot EFDT10-J2U2 EFDCT10-J2U2
2 Circuit, 2 Circuit, Lights
2 Pilot Lights 1 Pilot Light

* Malleable iron body and aluminum cover. For aluminum body, add suffix —A. ‡ Aluminum body not available. For tandem bodies, external
seals must be installed within 5 feet of each conduit entrance for Class I, Groups C and D. Pilot Lights furnished with 6W, 120V A.C. 6S6
lamp and red jewel—Other colored jewels and LED’s listed on page 17. See page 16 for push button accessories and parts.
◊ Shaded area indicates items suitable for Class I, Div. 1 and 2, Groups B, C and D; Class II, Groups E, F and G and Class III.
For Class I, Group B, external seals must be installed at each conduit entrance.
Dimensions on pages 24 and 25.
Effective September, 2005 800-621-1506
Copyright 2005 www.appletonelec.com
PAGE 10
Class I, Div. 1 and 2
M- 11
Groups B◊,C,D EDS Factory Sealed Push Button
Class II, Div. 1 and 2 Stations with Rocker Arm Handle:
Groups E,F,G
Class III Explosionproof, Dust- Ignitionproof
NEMA 3,7BCD,9EFG UNILETS® for use with Threaded Metal Conduit.
10 Ampere, 600V A.C. Max. for Heavy Duty Use.
Furnished with Internal Ground Screw.
Hub Size, Nameplate Catalog Number
Inches Description Marking Dead-End Feed-Thru

Single Gang◊
Malleable Iron Body and Cover*
Momentary Contact

1/2 1 Circuit Specify EDS150-RU1 EDSC150-RU1


3/4 Universal EDS175-RU1 EDSC175-RU1
1 EDS110-RU1 EDSC110-RU1

1/2 2 Circuits Specify ——— EDSC150-RU2


3/4 Universal EDS175-RU2 EDSC175-RU2
1 EDS110-RU2 EDSC110-RU2

Two Gang
Malleable Iron Body and Cover*
Momentary Contact

1/2 2 Circuits Specify ——— EDSC250-RU1


3/4 Universal EDS275-RU1 EDSC275-RU1
1 EDS210-RU1 EDSC210-RU1

1/2 4 Circuits Specify ——— EDSC250-RU2


3/4 Universal EDS275-RU2 EDSC275-RU2
1 EDS210-RU2 EDSC210-RU2

Nameplate Cover and Chamber


Description Marking with Device

Momentary Contact

1 Circuit Universal Specify EFK-RU1-Q

2 Circuits Universal Specify EFK-RU2-Q


M

Cover and Chamber


with Device

◊ Shaded area indicates items suitable for Class I,


Group B, in addition to Class I, Groups C and D; Class II, Groups E, F, and G; and Class III.
*For aluminum body, add suffix —A. (not suitable for Class I, Group B). For dimensions, see page 24.

Effective September, 2005 800-621-1506


Copyright 2005 www.appletonelec.com
PAGE 11
M- 12
Class I, Div. 1 and 2
Groups B◊,C,D EFD/EFDB Factory Sealed
Class II, Div. 1 and 2 Dust Cap Push Button Stations:
Groups E,F,G
Class III Explosionproof, Dust- Ignitionproof
NEMA 3,7CD,9EFG UNILETS® for use with Threaded Metal Conduit.
10 Ampere, 600V A.C. Max. for Heavy Duty Use.
Momentary Contact. Furnished with Internal Ground Screw.
U.S. Pat. 3,699,276 Hub Size, Nameplate Catalog Number
Patented Canada 1974 Inches Description Marking Dead-End Feed-Thru

Single Gang*◊

3/4 1 Circuit Specify EFDB175-DU1* EFDCB175-DU1*


1 Universal EFDB110-DU1* EFDCB110-DU1*

3/4 2 Circuits Specify EFDB175-DU2* EFDCB175-DU2*


1 Universal EFDB110-DU2* EFDCB110-DU2*

Three Device‡

3/4 2 Circuits Specify EFDL75-J1DU2 EFDCL75-J1DU2


1 Universal EFDL10-J1DU2 EFDCL10-J1DU2
and 1 Pilot
Light

Nameplate Catalog
Description Marking Number

Push Button and Replacement Cap


Dust Cap
Push Button STOP-START-BLANK SPBB-DU1-Q

Replacement
Dust Cap Only STOP-START-BLANK DC-Q

Nameplate STOP-START-BLANK DU-NP-Q

Has 1/2 - 14NPSM thread size. Supplied with 1/2” to 3/4” enlarger.

Covers Complete with Pilot Lights,


Push Buttons—Factory-Sealed
1 Circuit Specify EFKB-DU1
Universal

2 Circuits Specify EFKB-DU2


Universal
M

2 Circuits Specify EFKL-J1DU2★★


Universal
and 1 Pilot Light

* Malleable iron body and aluminum cover. For aluminum body, add suffix —A. ‡ Aluminum body not available. ★★ For use with three device mounting bodies.
◊ Shaded area indicates items suitable for Class I, Div. 1 and 2, Groups B, C and D; Class II, Groups E, F and G and Class III.
For Class I, Group B, external seals must be installed at each conduit entrance.
Dimensions on pages 24 and 25.

Effective September, 2005 800-621-1506


Copyright 2005 www.appletonelec.com
PAGE 12
Class I, Div. 1 and 2
M- 13
Groups B◊,C,D EFD/EFDB Factory Sealed
Class II, Div. 1 and 2 Pilot Light Stations:
Groups E,F,G
Class III Explosionproof, Dust- Ignitionproof
NEMA 3,7CD,9EFG UNILETS® for use with Threaded Metal Conduit.
Pilot Light Furnished with 6W, 120V A.C. 6S6 Lamp and Red Jewel.†
Furnished with Internal Ground Screw.
Hub Size, Catalog Number
Inches Description Dead-End Feed-Thru

Single Gang*◊

1/2 One EFDB150-J1 EFDCB150-J1


3/4 Pilot Light EFDB175-J1 EFDCB175-J1
1 EFDB110-J1 EFDCB110-J1

1/2 Two EFDB150-J2 EFDCB150-J2


3/4 Pilot Lights EFDB175-J2 EFDCB175-J2
1 EFDB110-J2 EFDCB110-J2

Two Gang*

1/2 Two EFD250-J1 EFDC250-J1


3/4 Pilot Lights EFD275-J1 EFDC275-J1
1 EFD210-J1 EFDC210-J1

1/2 Four EFD250-J2 EFDC250-J2


3/4 Pilot Lights EFD275-J2 EFDC275-J2
1 EFD210-J2 EFDC210-J2

Three Device‡

1/2 Three EFDL50-J3 EFDCL50-J3


3/4 Pilot Lights EFDL75-J3 EFDCL75-J3
1 EFDL10-J3 EFDCL10-J3

Two Gang Tandem

1/2 Two EFDT50-J1 EFDCT50-J1


3/4 Pilot Lights EFDT75-J1 EFDCT75-J1
1 EFDT10-J1 EFDCT10-J1

1/2 Four EFDT50-J2 EFDCT50-J2


M

3/4 Pilot Lights EFDT75-J2 EFDCT75-J2


1 EFDT10-J2 EFDCT10-J2

† Other colored jewels, LED’s, and pilot light accessories and parts are listed on page 17. Dimensions on pages 24 and 25.
* Malleable iron body and aluminum cover. For aluminum body, add suffix —A. ‡ Aluminum body not available. For tandem bodies,
external seals must be installed within 5 feet of each conduit entrance for Class I, Groups C and D.
◊ Shaded area indicates items suitable for Class I, Groups B, C and D; Class II, Groups E, F, and G; and Class III. For Class I, Group B
external seals must be installed at each conduit entrance.

Effective September, 2005 800-621-1506


Copyright 2005 www.appletonelec.com
PAGE 13
M- 14
Class I, Div. 1 and 2
Groups B◊,C,D EFDB Factory Sealed Selector
Class II, Div. 1 and 2 Switches and Photocontrols:
Groups E,F,G
Class III Explosionproof, Dust- Ignitionproof
NEMA 3,7CD,9EFG UNILETS® for use with Threaded Metal Conduit.
10 Ampere, 600V A.C. Max. for Heavy Duty Use.
Furnished with Internal Ground Screw.
Hub Size, Diagram Catalog Number
Selector Switches Inches Description Left Center Right Dead-End Feed-Thru

Single Gang*◊ Maintained Contact

1/2 2 Position, None EFDB150-12 EFDCB150-12


3/4 2 Circuit EFDB175-12 EFDCB175-12
1 EFDB110-12 EFDCB110-12

1/2 2 Position, None EFDB150-35 EFDCB150-35


3/4 4 Circuits EFDB175-35 EFDCB175-35
1 EFDB110-35 EFDCB110-35

Three position units can be supplied for momentary contact right position, spring return to
center, maintained contact left position. Add suffix —SRC.

1/2 3 Position, EFDB150-102 EFDCB150-102


3/4 2 Circuit EFDB175-102 EFDCB175-102
1 EFDB110-102 EFDCB110-102

1/2 3 Position, EFDB150-345 EFDCB150-345


3/4 4 Circuits EFDB175-345 EFDCB175-345
1 EFDB110-345 EFDCB110-345
Note: Standard legend plate reads HAND OFF AUTO

Two Position Nameplates Three Position Nameplates

Forward—Reverse SLNP-FRQ Forward—Off—Reverse SLNP-FORQ


Hand—Auto SLNP-HAQ Hand—Off—Auto SLNP-HOAQ
On—Off SLNP-OO Run—Off—Jog SLNP-ROJQ
Start—Stop SLNP-SS Blank SLNP-B3
Blank SLNP-BQ Reverse—Off—Forward SLNP-ROFQ
Two Position Three Position Up—Down SLNP-UDQ Auto—Off—Hand SLNP-AOHQ
Nameplate Nameplate Run—Job SLNP-RJQ Hand—Off—Remote SLNP-HORQ
Auto—Hand SLNP-AHQ 1—Off—2 SLNP-102Q
Off—Remote SLNP-ORQ Jog—Off—Run SLNP-JORQ
Stop—Run—Start SLNP-SRSQ
Local—Off—Remote SLNP-LORQ

Selector Switch Locking Devices


Permit locking in any position.

Two or Three Positions SBL-3-Q

Hub Size, Max. Max. Catalog Number


Photocontrols Inches Voltage Current VA Dead-End Feed-Thru

1/2 120 8.3A 1000 EFDB150PC120 EFDCB150PC120


3/4 120 8.3A 1000 EFDB175PC120 EFDCB175PC120
M

1 120 8.3A 1000 EFDB110PC120 EFDCB110PC120

1/2 208-277 3.5A 1000 EFDB150PC277 EFDCB150PC277


3/4 208-277 3.5A 1000 EFDB175PC277 EFDCB175PC277
1 208-277 3.5A 1000 EFDB110PC277 EFDCB110PC277

* Malleable iron body and aluminum cover. For aluminum body, add suffix —A. (Suitable for Class I, Div. 1 and 2, Group B—single gang only).
† Supplied as standard with maintained contact selector switches. Specify catalog number from nameplate listings if other than
standard nameplate is desired.
Shaded area indicates items suitable for Class I, Div. 1 and 2, Groups B, C and D; Class II, Groups E, F and G and Class III. For
◊ Class I, Group B, external seals must be installed at each conduit entrance.
Effective September, 2005 800-621-1506
Copyright 2005 www.appletonelec.com
PAGE 14
Class I, Div. 1 and 2
M- 15
Groups C,D EFDB Factory Sealed Selector
Class II, Div. 1 and 2 Switches and Cover Assemblies:
Groups E,F,G
Class III Explosionproof, Dust- Ignitionproof
NEMA 3,7CD,9EFG 10 Ampere, 600V A.C. Max. for Heavy Duty Use.

EFDB Selector Switch Operator/Switch Assembly (Maintained Contact)

Thread Switch Switch


Size Diagram Assembly Assembly
(In., NPSM) Description Left Center Right Only with Cover

1/2 2 Position, None SSBA1-2Q EFKB-12


2 Circuit

1/2 2 Position, None SSBA2-2Q EFKB-35


4 Circuits

1/2 3 Position, SSBA1-3Q EFKB-102


2 Circuit

1/2 3 Position, SSBA2-3Q EFKB-345


4 Circuits

EFDB Selector Switch Operator/Switch Assembly (Modified Operations)


Thread Switch Switch
Size Diagram Assembly Assembly
(In., NPSM) Description Left Center Right Only with Cover
1/2 3 Position, SSBAS-1-3 EFKB-102-SRC
2 Circuit

1/2 3 Position, SSBAS-2-3 EFKB-345-SRC


4 Circuits
Momentary contact right position. Spring return to center. Maintained contact left position.
Note: Standard legend plate reads HAND OFF AUTO

1/2 3 Position, SSBASL-1-3 EFKB-102-SLC


2 Circuit

1/2 3 Position, SSBASL-2-3 EFKB-345-SLC


4 Circuits
Momentary contact left position. Spring return to center. Maintained contact right position.
Note: Standard legend plate reads AUTO OFF HAND

1/2 3 Position, SSBASRA-2-3 EFKB-637-SRC


4 Circuit
Momentary contact right position. Spring return to center. Maintained contact left position.
Note: Standard legend plate reads STOP RUN START
M

Effective September, 2005 800-621-1506


Copyright 2005 www.appletonelec.com
PAGE 15
M- 16
Class I, Div. 1 and 2
Groups B*,C,D EFD/EFDB Push Buttons:
Class II, Div. 1 and 2 Accessories and Parts
Groups E,F,G
Class III

Description Catalog Number


Push Button, Factory Sealed - Momentar y Contact
10 Amp 600V A.C. Heavy Duty 1/2” thread size. Furnished with 1/2” to 3/4” enlarger,
Weather Boot, Guard, Start, Stop and Blank Nameplates.

Universal SPBB-U1-Q

Push Button, Factory Sealed - Maintained Conta ct


10 Amp 600V A.C. Heavy Duty 1/2” thread size. Furnished with 1/2” to 3/4” enlarger,
Maintained Momentary Guard not furnished.
Contact Contact
Universal SMPB-U1-Q

Rectangular Button with Weather Boot


Furnished with Start, Stop and Blank Nameplates. NBN-WB

Nameplates for Rectangular Push Buttons


Blank SNP-B-Q Off SNP-OFF-Q
Forward SNP-FWD-Q On SNP-ON-Q
Jog SNP-JOG-Q Reverse SNP-REV-Q

Run SNP-RUN-Q Open SNP-OPEN-Q


Stop SNP-SP-Q Close SNP-CLOSE-Q
Start SNP-ST-Q Up SNP-UP-Q

Down SNP-DOWN-Q Test SNP-TEST-Q


Fast SNP-FAST-Q Low SNP-LOW-Q
Slow SNP-SLOW-Q High SNP-HIGH-Q

Raise SNP-RAISE-Q
Lower SNP-LOWER-Q
Reset SNP-RESET-Q

Push Button Replacement Locking Guards-


Glass Reinforced Polypropylene (Gasketed)
Has hole for 1/4” hasp.

Single Guard (Maintained Switch) SMPB-LG


Single Guard NPB-LG1
Double Guard NPB-LG2
Maintained Single Double Single Guard (No Lockout Holes) NPB-LG1-LL
Switch Guard Guard Guard Double Guard (No Lockout Holes) NPB-LG2-LL

Push Button Securing Rod with Chain-


Stainless Steel (For use with Single Guard Only) NBL-SR

Mushroom Button with Weather Boot (Gasketed)


For use with Momentary Contact
Black NMRB-BL
Green NMRB-GR
M

Red NMRB-RE

For use with For use with Mushroom Button (For use with Maintained Contact)
Maintained Momentary Solid-colored non-metallic button.
Red NMRBM-RE

Nameplates For Mushroom Head Push Button (Momentary & Maintained)


Start MNPSTQ
Stop MNPSPQ
Emergency Stop MNPESTPQ
Blank MNPBQ
*Suitable for Class I, Group B when installed in an enclosure rated for Class I, Group B.
Effective September, 2005 800-621-1506
Copyright 2005 www.appletonelec.com
PAGE 16
Class I, Div. 1 and 2
M- 17
Groups B*,C,D
EFD/EFDB Pilot Lights:
Class II, Div. 1 and 2 Accessories and Parts
Groups E,F,G
Class III

Description Catalog Number

Pilot Light, Factory Sealed – Incandescent


Furnished with 6S6 120V incandescent lamp, jewel and guard. Has 18” long, type SFF-2
(150°C) pigtail leads. Body has 3/4” straight thread (NPSM).

With Red Jewel SPLSREB


Pilot With Green Jewel SPLSGRB
Light With Amber Jewel SPLSAMB
With Blue Jewel SPLSBLB
With Clear Jewel SPLSCLB
With Opal Jewel SPLSOPB

Pilot Light, Factory Sealed – LED


Furnished with candelabra base 120V LED, jewel and guard. Has 18” long, type SFF-2
Chamber (150°C) pigtail leads. Body has 3/4” straight thread (NPSM).
Only
With Red LED, Clear Jewel SPLNSREB
With Green LED, Clear Jewel SPLNSGRB
With Amber LED, Clear Jewel SPLNSAMB

Chamber Only SPLSSCB


(Same as above, less jewel, guard and lamp)

Pilot Light Jewel/Guard Assembly


The below catalog numbers indicate an assembly of the Pilot Light Jewels and Guards.
Jewels and Guards are not available as separate items.

Amber Jewel/Guard JGBNA


Blue Jewel/Guard JGBNB
Clear Jewel/Guard JGBNC
Green Jewel/Guard JGBNG
Opal Jewel/Guard JGBNO
Red Jewel/Guard JGBNR

Transformer
Add Suffix as listed below. Transformer clamps directly to pilot light barrel.
Only one pilot light transformer assembly per one gang body.
Primary Voltage Lamp Voltage Suffix
220 120 TR2
277 120 TR3
440 120 TR4
550 120 TR5
M

Clear Bulbs
Furnished with candelabra base. 6W, 120V Type 6S6 EPL-B6W
LED Replacements
Furnished with candelabra base. 120 VAC, 10 mA

Red LED EPLLEDR


Green LED EPLLEDG
Amber LED EPLLEDA

*Suitable for Class I, Group B when installed in an enclosure rated for Class I, Group B.
Effective September, 2005 800-621-1506
Copyright 2005 www.appletonelec.com
PAGE 17
M- 18
EFD/EFDB Series Pilot Lights:
Accessories

Description Catalog Number

Nameplates for Pilot Light


Blank LNPBQ
Forward LNPFWDQ
Jog LNPJOGQ
Run LNPRUNQ
Stop LNPSPQ

Start LNPSTQ
Down LNPDOWNQ
Fast LNPFASTQ
Slow LNPSLOWQ
Raise LNPRAISEQ

Lower LNPLOWERQ
Reset LNPRESETQ
Off LNPOFFQ
On LNPONQ
Reverse LNPREVQ

Close LNPCLOSEQ
Open LNPOPENQ
Up LNPUPQ
Test LNPTESTQ
Low LNPLOWQ

High LNPHIGHQ
M

Effective September, 2005 800-621-1506


Copyright 2005 www.appletonelec.com
PAGE 18
M- 19
NPBRKT Nameplate Mounting Bracket
For use with EFDB, EFS, Contender® and N1/N2 Series
Control Stations, Tumbler Switches and Manual Motor Starters.

Applications
• For mounting on EFDB, EFS, Con-
tender and Intraground series control
stations to make circuit description/
identification easy.
Features
• Pre-drilled holes in bottom of bracket
allow direct mounting to Appleton EFDB,
EFS, Contender and intraground series
control stations with existing cover bolts
(Intraground series bracket is mounted
using nameplate screws).
• Pre-drilled holes in middle of bracket
allow mounting of customer’s circuit
identification nameplate; epoxy glue
may also be used for mounting (phe-
nolic nameplate not included).
• Nameplate mounting bracket is cor-
rosion resistant stainless steel.
• Bracket eliminates costly field instal-
lation of drilling and tapping to accom-
modate circuit identification nameplate.
• Brackets fit side-by-side on 2, 3 and
4 gang boxes and 3 Device EFD Se-
ries.

Description Catalog Number*


Nameplate Mounting Bracket for EFDB and EFS series NPBRKT-EFDB
Nameplate Mounting Bracket for Contender® and 3 Device EFD Series NPBRKT-C0NT
Nameplate Mounting Bracket for N1/N2 series NPBRKT-N1N2

* To order bracket with either series control station or manual motor starter, add
suffix–NPBRKT to end of catalog number.

Dimensions (In Inches):


Note: Mount bracket between cover
screws and cover. Do not mount brack-
et between ground joint flame path
between cover and back box.

Secure
1.00 bracket
2.00 under cover
M

screws of
box.
Torque
cover
screws to
12ft - lbs.

Catalog No. A B C D E
NPBRKT-CONT 2.81 2.50 3.38 2.75 .27 x .33
NPBRKT-EFDB 2.38 2.50 3.00 2.75 .25
NPBRKT-N1N2 2.13 2.25 2.75 2.69 .16

Effective September, 2005 800-621-1506


Copyright 2005 www.appletonelec.com
PAGE 19
M- 20
Class I, Div. 1 and 2
Groups C,D EFKB Covers with Pilot Lights, Push Buttons,
Class II, Div. 1 and 2 or Photocontrol for EFD Bodies
Groups E,F,G
Class III All Covers are Copper-Free Aluminum.
Supplied with Four Captive Stainless Steel Bolts.

Nameplate Catalog
Description Marking Number
Cover complete with Push Button
Factory Sealed, Momentary Contact
For use on standard EFD bodies

1 Circuit Universal Specify* EFKB-U1


U1
2 Circuit Universal Specify* EFKB-U2
U2
Cover complete with Push Button
Factory Sealed, Maintained Contact
For use on standard EFDB bodies

1 Circuit Universal (Red) Specify EFKB-UM1

Cover complete with Pilot Lights


Factory Sealed, Momentary Contact
6W120V, Type 6S6 Lamp. For use on standard EFD bodies

One pilot light (red jewel†) and two Specify* EFKB-J1U2


universal push buttons
J1U2
One pilot light (red jewel†) and one Specify* EFKB-J1U1
universal push button

One pilot light (red jewel†) and one Specify* EFKB-J1DU1


universal push button–dust cap

One pilot light (red jewel†) Specify EFKB-J1


J1
Two pilot lights (red jewels†) Specify EFKB-J2

Photocontrol relay cover (120V) EFKB-PC120

Photocontrol relay cover (208-277V) EFKB-PC277

J2
M

* Start - Stop and Blank Nameplate Standard


†Other colored jewels listed on Page 17

Effective September, 2005 800-621-1506


Copyright 2005 www.appletonelec.com
PAGE 20
Class I, Div. 1 and 2
M- 21
Groups C,D ESK/EFK Covers for Pilot Lights, Push Buttons,
Class II, Div. 1 and 2 or Selector Switches for EFD Bodies
Groups E,F,G
Class III All Covers are Copper-Free Aluminum.
Supplied with Four Captive Stainless Steel Bolts*.

Catalog
Description Number
Covers Only — for use on standard EFD bodies
Supplied with 4 cover bolts and blank cover nameplate.

Push Button or Pilot Light Covers


3/4” tapped openings

One opening: one push button or ESKB-1PBQ


one pilot light

Two openings: two push buttons, ESKB-2PBQ


two pilot lights, or one of each

Three openings: three device (EFDL) EFKL-3HQ*


three push buttons or three pilot lights,
or combination of push button(s)
and pilot light(s)

Push Button or Selector Switch Cover


1/2” tapped openings.

Two openings: selector switch ESKB-2SPQ


or two push buttons
2SPQ

Push Button, Pilot Light or Selector Switch Covers


3/4” top and 1/2” bottom tapped openings.

One top and two bottom openings: ESKB-3JPBQ


one pilot light, two push buttons;
one pilot light, one selector switch.

Blank ESKB-BQ

* Cat. No. EFKL-3HQ supplied with 6 stainless steel non-captive bolts.

Effective September, 2005 800-621-1506


Copyright 2005 www.appletonelec.com
PAGE 21
M- 22
2
Class I, Div. 1 and 2
Groups C,D Mounting Bodies for EFD and EDS
Class II, Div. 1 and 2 Control Stations
Groups E,F,G
Class III Furnished with Internal Ground Screw.
NEMA 7CD,9EFG

Hub Size, Dead-End Catalog Numbers Feed-Thru Catalog Numbers


Inches Malleable Iron Aluminum Malleable Iron Aluminum

Single Gang, Two Gang, Tandem, and Three Device Bodies


Single Gang

1/2 EFD150-NL-Q EFD150A-NL-Q EFDC150-NL-Q EFDC150A-NL-Q


3/4 EFD175-NL-Q EFD175A-NL-Q EFDC175-NL-Q EFDC175A-NL-Q
1 EFD110-NL-Q EFD110A-NL-Q EFDC110-NL-Q EFDC110A-NL-Q

Two-Gang

1/2 EFD250-NL-Q EFD250A-NL-Q EFDC250-NL-Q EFDC250A-NL-Q


3/4 EFD275-NL-Q EFD275A-NL-Q EFDC275-NL-Q EFDC275A-NL-Q
1 EFD210-NL-Q EFD210A-NL-Q EFDC210-NL-Q EFDC210A-NL-Q

Tandem †

1/2 EFDT50-NL-Q —— EFDCT50-NL-Q ——


3/4 EFDT75-NL-Q —— EFDCT75-NL-Q ——
1 EFDT10-NL-Q —— EFDCT10-NL-Q ——

Three Device
For use with EFKL Covers.

1/2 EFDL50-Q —— EFDCL50-Q ——


3/4 EFDL75-Q —— EFDCL75-Q ——
1 EFDL10-Q —— EFDCL10-Q ——

Blank Bodies for Brazed Hubs


Deep—malleable iron

Construct complete catalog number


Gang Cat. No.
per page M-23. Hubs will be located
1 Gang EFD-1-NL
in center of walls and evenly spaced
2 Gang EFD-2-NL
unless otherwise specified. Where
3 Gang EFD-3-NL
spacings are critical, submit sketch
4 Gang EFD-4-NL
M

showing spacing requirements.


5 Gang EFD-5-NL

Covers and Devices are listed on Pages M-12,15,20, and 21. Accessories on Pages M-16, 17, and 18. Dimensions on Pages M-24 and 25.
† For tandem bodies, external seals must be installed within 5 feet of each conduit entrance for Class I, Groups C and D.

Effective September, 2005 800-621-1506


Copyright 2005 www.appletonelec.com
PAGE 22
M- 23
Ordering Information:
EFD Cast Device Boxes; Blank Bodies
for Brazed Threaded Hubs
Single, Two, Three, Four and Five Gang Boxes.
Brazed Threaded Hubs for Rigid Conduit, 1/2” thru 1”;
Brazed Union Hubs, 1/2” thru 1”.

Determine catalog number as follows: Standard Hub Arrangement Diagrams


(1) select EFD device box catalog num- Hub “a” is always TOP of box
ber; (2) select “Standard Hub Arrange-
ment Diagram” number; and (3) select Two, Three, Four and Five Gang (Front View)
symbols that represent hub sizes from
“Symbol Table.” (Use “0” where no hub
is required, and separate the various
divisions of the complete catalog num-
ber by dashes.)
Example
The blank body device box selected
is EFD3NL and the hub arrangement
is diagram #8. Hub “a” is to be 3/4”
BRAZED THREADED; hub “b”, 1”
BRAZED THREADED; hub “c”, 3/4”
BRAZED THREADED; hub “d”, no hub
is required; and hub “e”, 1” BRAZED
UNION. The complete catalog number
will be:
EFD–3NL–8–2320T

Single Gang (Front View)

Symbol Table
Brazed Brazed
Hub Threaded Union
Size Hub Hub
(Inches) Symbol Symbol If a “Standard Hub Arrangement” is not suitable for the application, or when hubs
Blank 0 0 are to be more accurately spaced, submit sketch locating hubs (1) from centerlines
1/2 1 1E of walls and (2) from outside back of box (or from mounting lug surface if lugs
3/4 2 2E are supplied).
1 3 3E All hubs will be located in centerlines of walls and evenly spaced unless
otherwise specified.
Effective September, 2005 800-621-1506
Copyright 2005 www.appletonelec.com
PAGE 23
M- 24
Dimensions: EFD/EFDB Push Buttons,
EFDB Dust Cap Push Buttons;
Pilot Light; EDS Rocker Arm Push Button

11/32” Dia.
EFD/EFDB (2) Mtg. Holes
Single and
Two Gang
Combination
Pilot Light
and Push Buttons

EFD/EFDB
Single Gang
Dust Cap
Push Button,
Single Gang
Maintained Contact
Push Button, and
Photo Control

EDS
Single and
Two Gang
Rocker Arm
Push Button
M

Dimensions in Inches Dimensions in Centimeters


Hub Size A B C A B C
1/2” and 3/4” 5.38 6.13 .78 13.7 15.6 2.0
1” 5.50 6.31 .94 14.0 16.0 2.4

Effective September, 2005 800-621-1506


Copyright 2005 www.appletonelec.com
PAGE 24
M- 25
Dimensions:
EFD Three Device and Two Gang Tandem

EFD Three
Device
Pilot Light 1/2” and 3/4” Hub = .78” (2.0cm)
and Push 1” Hub = .94” (2.4cm)
Buttons

9/32” Dia. Hole

11/32” Dia.
(2) Mtg. Holes
1/2” & 3/4” Hub = 8.88” (22.6cm)
1” Hub = 9.31” (23.6cm)

1/2” and 3/4” Hub = .78” (2.0cm)


EFD Two 5/16” Dia.
1” Hub = .94” (2.4cm)
(2) Mtg. Holes
Gang
Tandem
Pilot Light
and Push
Buttons

9/32” Dia. Hole

Effective September, 2005 800-621-1506


Copyright 2005 www.appletonelec.com
PAGE 25

You might also like