Canon Radrex Brochure
Canon Radrex Brochure
Canon Radrex Brochure
radiography systems
https://global.medical.canon
©Canon Medical Systems Corporation 2011-2018. All rights reserved.
Design and specifications are subject to change without notice.
Model number: MRAD-A80S, MRAD-A50S, MRAD-A32S, MRAD-A25S
MCAXR0232EAD 2018-02 CMSC/D/Printed in Japan
Canon Medical Systems Corporation meets internationally recognized standards for Quality Management System ISO 9001,
ISO 13485. Canon Medical Systems Corporation meets the Environmental Management System standard ISO 14001.
RADREX and Made for Life are trademarks of Canon Medical Systems Corporation.
High-quality
radiography – a most
important tool
Basic radiography requirements neatly fitted into a balanced and optimized package
• Reliable and user-friendly
• High image quality
• Digital upgradeability - by combining with Canon Medical Systems Flat Panel Detector
(TFD-2020A)
Overall savings Wide range of applications Easy operation High image quality
These systems are excellent space savers and can The X-ray tube supports, with their wide range of These systems are designed with the user’s needs in The Bucky device employs the renowned oscillating
be installed swiftly. Built to have a long working life, movement, are ideal for a large variety of mind, and have excellent positioning characteristics. system, so clear images are a matter of course. In
they use fully reliable components. radiographic functions. The Bucky table has a wide Furthermore, the generators are provided with addition, the generators employ a high-frequency
range of accessories which are designed to be microprocessor and memory functions. Various inverter, ensuring a stable, high output and high-
easily attached (optional). They support the lateral radiographic parameters can be registered and quality images.
radiographic procedure and compression of the then retrieved with a one-touch operation.
abdomen, expanding the variety of examinations. Simple and easy cassette (or FPD) loading.
Tabletop protective mat reduce the burden of Just a touch is enough to operate the anatomical
patients. positioning functions.
2 3
System variations
Canon Medical Systems RADREX could maximize productivity, performance and patient
care with the variety of system for optimization of clinical application.
All of RADREX system have availability to Digital Radiography system by combining with
MRAD-A80S MRAD-A50S / MRAD-A32S
Canon Medical Systems Flat Panel Detector (TFD-2020A).
High power full system Standard system
MRAD-A32S / MRAD-A25S
Basic system
4 5
Raising the standard for
productivity and performance
Availability to Digital radiography system with cassette size FPD and full size FPD
• Reducing examination time
• Providing optimum image quality with CsI type FPD and Advanced image processor
• Enhancing various clinical application
6 7
Components
X-ray generator Ceiling-suspended tube support
KXO-80SS
80 kW, 150 kV, 1000 mA
• Color liquid touch panel
• One-touch control
• Max. 672 programs (7 × 24 × 4)
• High frequency new inverter
• Small foot print cabinet
• CR/DR serial communication (option)
• Solidet AEC detector combination (option)
DST-2000A DST-1000A
• Column vertical movement: Approx. 170 cm • Column vertical movement: Approx. 170 cm
• Distance from the ceiling mounting surface to the X-ray • Distance from the ceiling mounting surface to the X-ray
tube focus: Approx. 85 cm to 255 cm (varies depending tube focus: Approx. 85 cm to 255 cm (varies depending
on the X-ray tube unit and X-ray beam limiting device on the X-ray tube unit and X-ray beam limiting device
used in combination.) used in combination.)
• Locking system: Electromagnetic brake • Locking system: Electromagnetic brake
KXO-50SS • Collimator: Auto-Collimation • Collimator: Manual-Collimation
50 kW, 150 kV, 630 mA • X-ray setting can be changed at tube support
• One-touch control
• Max. 3996 programs
• High frequency new inverter
• Small foot print cabinet
• CR/DR serial communication (option) X-ray tube assembly support unit
• Solidet AEC detector combination (option)
DS-TA-5A
Floor-to-ceiling type
• Longitudial movement : 250 cm
KXO-32SS KXO-25SS • Lateral movement : 40 cm
32 kW, 150 kV, 500 mA 25 kW, 150 kV, 320 mA • Vertical movement : 166 cm
• Locking system : Electromagnetic brake
• One-touch control • One-touch control
• Collimator : Manual-Collimation
• Max. 3996 programs • Max. 3996 programs
• High frequency new inverter • High frequency new inverter
• Small foot print cabinet • CR/DR serial communication (option)
• CR/DR serial communication (option)
• Solidet AEC detector combination (option)
8 9
Components
Bucky table Bucky stand X-ray tube assembly
DRX-3724HD
Focal spot : 0.6 mm/1.2 mm
Anode heat capacity : 210 kJ (300 kHU)
Maximum rating : 40 kW/100 kW
DRX-1824B
Focal spot : 0.6 mm/1.2 mm
Anode heat capacity : 100 kJ (140 kHU)
Maximum rating : 17.5 kW/40 kW
DRX-1603B
EBT-100A Elevator-type Bucky table FBT-10A Floating-top Bucky table BS-02A Vertical Bucky stand
Focal spot : 1.0 mm/2.0 mm
Tabletop Tabletop Bucky device Anode heat capacity : 100 kJ (140 kHU)
• Tabletop size : 82 cm × 230 cm • Tabletop size : 82 cm × 210 cm • Grid movement : Oscillation
• Height of the tabletop : 35 cm to 95 cm • Height of the tabletop : 68 cm Maximum rating : 22.5 kW/47 kW
• Cassette size : 18 cm × 24 cm to 35 cm × 48 cm
Floating stroke Floating stroke (8” × 10” to 14” × 17”)
• Longitudinal movement : 100 cm • Longitudinal movement : 90 cm
• Bucky movement : 120 cm
• Lateral movement : ±12 cm • Lateral movement : ±12 cm
Bucky device Bucky device
• Grid movement : Oscillation • Grid movement : Oscillation
• Cassette size : 18 cm × 24 cm to 35 cm × 48 cm • Cassette size : 18 cm × 24 cm to 35 cm × 48 cm
(8” × 10” to 14” × 17”) (8” × 10” to 14” × 17”)
• Longitudinal movement : 48 cm • Longitudinal movement : 38 cm
Disclaimer: Some features presented in this brochure may not be commercially available on all systems shown or may require the purchase of additional options.
Please contact your local representative from Canon Medical Systems for details.
10 11