Location via proxy:   [ UP ]  
[Report a bug]   [Manage cookies]                

BP Man: Solar Pumping Project

Download as pdf or txt
Download as pdf or txt
You are on page 1of 5

BERNT LORENTZ GmbH

Siebenstuecken 24 Tel: +49-(0)4193 8806-700


D-24558 Henstedt-Ulzburg Fax:
www.lorentz.de info2018@lorentz.de

Thursday, June 10, 2021


Bp Man

Solar pumping project

Note: Head : 160 m


Output : 22 m3/day

Parameter
Location: Indonesia, Waingapu (10° South; 120° Water temperature: 25 °C
East)
Required daily output: 20 m³; Sizing for average month Dirt loss: 5,0 % Motor cable: 50 m
Pipe type: - Total dynamic head: 160 m Pipe length: -

Products Quantity Details


PS2-4000 C-SJ3-32 1 pc. Submersible pump system including controller with DataModule, motor and pump end
SLN200P 24 pc. 4.800 Wp; 8 x 3 modules; 15 ° tilted
Motor cable 50 m 4 mm² 3-phase cable for power and 1-phase cable for ground
Accessories 1 set Well Probe V2, PV Disconnect 440-40-3, Surge Protector2

Sun Sensor setting in PumpScanner min. 200 W/m²


Daily output in average month 22 m³
Daily values Jan Feb Mar Apr May Jun Jul Aug Sep Oct Nov Dec Av.

Output [m³]

Energy [kWh] 20 20 23 24 24 23 23 26 27 26 23 21 23
Irradiation [kWh/m²] 4,8 4,9 5,5 5,8 5,8 5,4 5,6 6,3 6,7 6,5 5,7 5,2 5,7
Rainfall [mm] 6,7 6,7 6,0 3,5 1,7 0,97 0,57 0,23 0,30 0,87 2,3 5,3 2,9
Ambient temp. [°C] 26 26 26 26 26 26 26 26 27 28 27 27 27

Hourly values 6:00 7:00 8:00 9:00 10:00 11:00 12:00 13:00 14:00 15:00 16:00 17:00 18:00

Output [m³/h]

Energy [kWh] 0,030 0,71 1,5 2,2 2,8 3,1 3,1 3,0 2,7 2,2 1,5 0,69 0,029
Irradiation [kWh/m²] 0,007 0,16 0,35 0,52 0,66 0,75 0,78 0,75 0,66 0,52 0,35 0,16 0,007
Ambient temp. [°C] 22 22 23 25 27 29 31 32 32 32 32 31 31

Created by LORENTZ COMPASS 3.1.0.183


1/5 All specifications and information are given with good intent, errors are possible and products may be subject to change
without notice.
BERNT LORENTZ GmbH
Siebenstuecken 24 Tel: +49-(0)4193 8806-700
D-24558 Henstedt-Ulzburg Fax:
www.lorentz.de info2018@lorentz.de

Thursday, June 10, 2021


Bp Man

Solar pumping project

System characteristic

Min. 800 W/m², 20 °C Max./STC*


PV generator Cell temperature [°C] 46 25
Temperature loss [%] 8,4 -
Dirt loss [%] 5,0 -
Pmax [Wp] 3.340 4.800
Vmp [V] 222 242
Imp [A] 15 20
Voc [V] 261 286
Isc [A] 17 22
Pout [W] 3.070 -
Vout [V] 240 -
Iout [A] 13 -
Motor cable Power loss [%] 1,3 2,9 2,9
Pump systems Motor power [W] 707 2.960 2.960
Motor voltage [V EC] 156 212 212
Motor current [A] 4,5 14 14
Motor speed [rpm] 2.605 3.070 3.070
Flow rate [m³/h] 0 3,2 3,2
Efficiency [%] 0 45 46
*STC: Standard test conditions for photovoltaic modules, 1000 W/m² solar iradiance, 25 °C cell temperature

Created by LORENTZ COMPASS 3.1.0.183


2/5 All specifications and information are given with good intent, errors are possible and products may be subject to change
without notice.
BERNT LORENTZ GmbH
Siebenstuecken 24 Tel: +49-(0)4193 8806-700
D-24558 Henstedt-Ulzburg Fax:
www.lorentz.de info2018@lorentz.de

Thursday, June 10, 2021


Bp Man

Solar pumping project

Wiring diagram

Created by LORENTZ COMPASS 3.1.0.183


3/5 All specifications and information are given with good intent, errors are possible and products may be subject to change
without notice.
BERNT LORENTZ GmbH
Siebenstuecken 24 Tel: +49-(0)4193 8806-700
D-24558 Henstedt-Ulzburg Fax:
www.lorentz.de info2018@lorentz.de

Thursday, June 10, 2021


Bp Man

Solar pumping project

System Layout

1: PS2 Controller 11: Float Switch


2: Submersible Pump 12: Sun Switch
3: Flow Sleeve 13: PV Disconnect
4: Well Probe 14: Lightning Surge Protector
5: Cable Splice Kit 15: PV Generator
6: Grounding Rod *It is recommended to install a Surge Protector at each
controller sensor input.
7: Surge Protector*
8: Safety Rope
9: Water Meter
10: Pressure Sensor

Created by LORENTZ COMPASS 3.1.0.183


4/5 All specifications and information are given with good intent, errors are possible and products may be subject to change
without notice.
BERNT LORENTZ GmbH
Siebenstuecken 24 Tel: +49-(0)4193 8806-700
D-24558 Henstedt-Ulzburg Fax:
www.lorentz.de info2018@lorentz.de

Thursday, June 10, 2021


Bp Man

Solar pumping project

Sizing Layout

H (Static head): Vertical height from the dynamic water level to the highest point of delivery.
B (Drawdown): Lowering of water level depending on flow rate and recovery rate of the well.
D (Pipeline inner diameter)
L (Pipe length): Entire pipeline from the pump outlet to the point of delivery. Ellbows and armatures must be added as an
equivalent length of pipeline.
M (Motor cable): The cable between controller and pump unit.
T (Tilt angle): Angle of the PV generator surface from the horizontal plane.

Created by LORENTZ COMPASS 3.1.0.183


5/5 All specifications and information are given with good intent, errors are possible and products may be subject to change
without notice.

You might also like