Location via proxy:   [ UP ]  
[Report a bug]   [Manage cookies]                

01 Fo

Download as pdf or txt
Download as pdf or txt
You are on page 1of 30

FC.14.r1 - p.

1
www.bmetenergy.com
BMET Energy Telecom Industry and Trade LLC

Oromia, Sebeta, Finfine Special Zone Sub City, Sebeta-Hawas Woreda


Kebele: Dima Guranda, Addis Ababa
Tel/Fax no: +251 11 3662034
Mail: info@bmetenergy.com
www.bmetenergy.com

FC.14.r1 - p.2
www.bmetenergy.com
CORRUGATED STEEL TAPE ARMORED
FIBER OPTIC CABLE

1. Outer PE Sheath
2. Corrugated Steel Tape
3. Inner PE Sheath
4. Yarns
5. Core Wrappings
6. Petroleum Jelly
7. Thixotropic Jelly
8. Loose Buffer Tube (Colored)
9. Optical Fiber (Colored)
10. Central Strength Member (FRP or Steel)

All MM and SM Fiber Types Available •


Outdoor type •
Multitube structure •
Corrugated steel tape armored •
Jelly filled core •
Dry Core Option •
In compliance with IEC Specs •

INSTALLATION APPLICATION
Outdoor fiber optic cable for direct burial Telecommunication, Video, Data
and duct installation where protection Transmission, CATV, Long Distance,
against rodents and moisture is required. Backbone, Local Area Network

TECHNICAL DATA
No of fibers : 1...144
Number of Buffer tubes : 1...12
Number of fiber/buffer tubes : 1...12
Nominal cable diameter (mm) : 15...23
Nominal weight (kg/km) : 440...750
Min. Pulling Tension (Nt) : 2500
Min. Crush Strength(Nt/100 mm) : 3500
Permissible Bending Radius (mm)
During/After Installation : 320/160
Temperature Range
Operation : -40 oC to + 70 oC
Installation : -20 oC to + 70 oC

Note: Special designs upto 672 fibers capacity are available upon request.

FC.14.r1 - p.3
www.bmetenergy.com
STEEL TAPE ARMORED FIBER OPTIC CABLE

1. Central Strength Member


2. Loose Buffer Tube (Colored)
3. Optical Fiber (Colored)
4. Thixotropic Jelly
5. Petroleum Jelly
6. Core Wrappings
7. Yarns
8. Aluminium Foil
9. Inner PE Sheath
10. Bitumenized Crepe Paper
11. Steel tape (2 layer) Armoring
12. Outer PE Sheath

All MM and SM Fiber Types Available •


Outdoor type •
Multitube structure •
Double PE Jacket •
Two layers of galvanized steel tape armoring •
Jelly filled core with Moisture Barrier •
Dry Core Option •
In compliance with IEC Specs •

INSTALLATION APPLICATION
Outdoor fiber optic cable for direct burial Telecommunication, Video, Data
and duct installation for heavy duty Transmission, CATV, Long Distance,
applications and where rodent protection Backbone, Local Area Network
is required.

TECHNICAL DATA
No of fibers : 1...144
Number of Buffer tubes : 1...12
Number of fiber/buffer tubes : 1...12
Nominal cable diameter (mm) : 17...24
Nominal weight (kg/km) : 330...580
Min. Pulling Tension (Nt) : 3000
Min. Crush Strength(Nt/100 mm) : 4000
Permissible Bending Radius (mm)
During/After Installation : 360/180
Temperature Range
Operation : -40 oC to + 70 oC
Installation : -20 oC to + 70 oC

Note: Special designs upto 672 fibers capacity are available upon request.

FC.14.r1 - p.4
www.bmetenergy.com
STEEL WIRE ARMORED FIBER OPTIC CABLE

1. Central Strength Member


2. Buffer Tube (Colored)
3. Optical Fiber (Colored)
4. Thixotropic Jelly
5. Petroleum Jelly
6. Core Wrappings
7. Yarns
8. Aluminium Foil
9. Inner PE Sheath
10. Crepe Paper
11. Steel Wire Armoring
12. Outer PE Sheath

All MM and SM Fiber Types Available •


Outdoor type •
Multitube structure •
Double PE Jacket •
Steel Wire Armored •
Jelly filled core with Moisture Barrier •
In compliance with IEC Specs •

INSTALLATION APPLICATION
Outdoor fiber optic cable for direct burial Telecommunication, Video, Data
and duct installation. These type of cables Transmission, CATV, Long Distance,
are used for heavy duty applications, river Backbone, Local Area Network
crossings and where rodent protections is
required.

TECHNICAL DATA
No of fibers : 1...144
Number of Buffer tubes : 1...12
Number of fiber/buffer tubes : 1...12
Nominal cable diameter (mm) : 18...25
Nominal weight (kg/km) : 600...900
Min. Pulling Tension (Nt) : 5000
Min. Crush Strength(Nt/100 mm) : 6000
Permissible Bending Radius (mm)
During/After Installation : 360/180
Temperature Range
Operation : -40 oC to + 80 oC
Installation : -20 oC to + 70 oC

Note: Special designs upto 288 fibers capacity are available upon request.

FC.14.r1 - p.5
www.bmetenergy.com
LIGHT WEIGHT NON-METALLIC FIBER OPTIC CABLE

1. Central Strength Member (FRP)


2. Loose Buffer Tube (Colored)
3. Optical Fiber (Colored)
4. Thixotropic Jelly
5. Petroleum Jelly
6. Core Wrappings
7. Aramid Yarns
8. Outer PE Sheath

All MM and SM Fiber Types Available •


Outdoor type •
Light weight •
Multitube structure •
Single PE Jacket •
Jelly filled core •
Non-metallic strength members •
Dry Core Option •
In compliance with IEC Specs •

INSTALLATION APPLICATION
Outdoor fiber optic cable for duct Telecommunication, Video, Data
installation and indoor use. Light and Transmission, CATV, Long Distance,
flexible for easy handling. This cable is Backbone, Local Area Network
mainly preferable for long distance
networks to be installed by blowing
method inside HDPE pipes for fast
installation.

TECHNICAL DATA
No of fibers : 1...144
Number of Buffer tubes : 1...12
Number of fiber/buffer tubes : 1...12
Nominal cable diameter (mm) : 11...16
Nominal weight (kg/km) : 110...220
Min. Pulling Tension (Nt) : 1000
Min. Crush Strength(Nt/100 mm) : 2000
Permissible Bending Radius (mm)
During/After Installation : 220/120
Temperature Range
Operation : -40 oC to + 70 oC
Installation : -20 oC to + 70 oC

Note: Instead of aramid yarns, glass yarns can be applied to increase the resistivity of
cables against rodent attacks. Special designs upto 672 fibers capacity are available
upon request.

FC.14.r1 - p.6
www.bmetenergy.com
LIGHT WEIGHT DUCT TYPE FIBER OPTIC CABLE

1. Central Strength Member (FRP or Steel)


2. Loose Buffer Tube (Colored)
3. Optical Fiber (Colored)
4. Thixotropic Jelly
5. Petroleum Jelly
6. Core Wrappings
7. Yarns
8. Aluminium Tape
9. Outer PE Sheath

All MM and SM Fiber Types Available •


Outdoor type •
Multitube structure •
Single PE Jacket •
Jelly filled core with moisture barrier •
Dry Core Option •
In compliance with IEC Specs •

INSTALLATION APPLICATION
Outdoor fiber optic cable for duct and Telecommunication, Video, Data
HDPE pipe installation and indoor use for Transmission, CATV, Long Distance,
easy handling and quick installation. Backbone, Local Area Network

TECHNICAL DATA
No of fibers : 1...144
Number of Buffer tubes : 1...12
Number of fiber/buffer tubes : 1...12
Nominal cable diameter (mm) : 11...17
Nominal weight (kg/km) : 120...230
Min. Pulling Tension (Nt) : 1500
Min. Crush Strength(Nt/100 mm) : 2200
Permissible Bending Radius (mm)
During/After Installation : 220/120
Temperature Range
Operation : -40 oC to + 70 oC
Installation : -20 oC to + 70 oC

Note: Instead of aluminium tape, corrugated steel tape can be applied to increase the
crush resistance and also resistivity of the cables against rodent attacks. Special
designs upto 672 fibers capacity are available upon request.

FC.14.r1 - p.7
www.bmetenergy.com
NON-METALLIC FIBER OPTIC CABLE

1. Central Strength Member (FRP)


2. Loose Buffer Tube (Colored)
3. Optical Fiber (Colored)
4. Thixotropic Jelly
5. Petroleum Jelly
6. Core Wrappings
7. Yarns
8. Inner PE Sheath
9. Filler
10. Aramid Yarns
11. Outer PE Sheath

All MM and SM Fiber Types Available •


Outdoor type •
Fully non-metallic •
Multitube structure •
Double PE Jacket •
Non-metallic strength members •
Jelly filled core •
Dry Core Option •
In compliance with IEC Specs •

INSTALLATION APPLICATION
Outdoor fiber optic cable for plastic duct Telecommunication, Video, Data
and HDPE pipe installation. This cable is Transmission, CATV, Long Distance,
mainly preferable for blowing type Backbone, Local Area Network
installation methods. These cables are
used for fast installation.

TECHNICAL DATA
No of fibers : 1...144
Number of Buffer tubes : 1...12
Number of fiber/buffer tubes : 1...12
Nominal cable diameter (mm) : 14...21
Nominal weight (kg/km) : 170...280
Min. Pulling Tension (Nt) : 1500
Min. Crush Strength(Nt/100 mm) : 2800
Permissible Bending Radius (mm)
During/After Installation : 280/140
Temperature Range
Operation : -40 oC to + 70 oC
Installation : -20 oC to + 70 oC

Note: Special designs upto 672 fibers capacity are available upon request.

FC.14.r1 - p.8
www.bmetenergy.com
SLOTTED CORE FIBER OPTIC CABLE

1. Central Strength Member (FRP)


2. Slotted Core
3. Optical Fiber (Colored)
4. Thixotropic Jelly
5. Core Wrappings
6. Outer PE Sheath

All MM and SM Fiber Types Available •


Outdoor type •
Light weight •
Small diameter •
Non-metallic •
Slotted core with single or multiple fibers •
Jelly filled core •
In compliance with IEC Specs •

INSTALLATION APPLICATION
Outdoor fiber optic cable for duct Telecommunication, Video, Data
installation and also suitable for indoor Transmission, CATV, Long Distance,
applications. Easy handling and quick Backbone, Local Area Network
installation.
Optional Constructions
TECHNICAL DATA 1. Steel Wire Armored
No of fibers : 1...48 2. Steel Tape Armored
Number of Slots : 6...12 3. Light Weight Duct
Number of Fiber/Slots : 1...8 4. Light Weight Non-metallic
Nominal cable diameter (mm) : 12...18 5. Non-metallic Duct
Nominal weight (kg/km) : 105...130 6. Corrugated Steel Tape Armored
Min. Pulling Tension (Nt) : 1100 7. Light Duty Aerial
Min. Crush Strength(Nt/100 mm) : 3000 8. Non-metallic Aerial (ADSS)
Permissible Bending Radius (mm) 9. Indoor
During/After Installation : 220/110
Temperature Range
Operation : -40 oC to + 70 oC
Installation : -20 oC to + 70 oC

FC.14.r1 - p.9
www.bmetenergy.com
SLOTTED CORE RIBBON FIBER OPTIC CABLE

1. Central Strength Member (FRP)


2. Ribbon Fibers (Colored)
3. Slotted Core
4. Thixotropic Jelly
5. Core Wrappings
6. Outer PE Sheath

All MM and SM Fiber Types Available •


Outdoor type •
Light weight •
Small diameter •
Non-metallic •
Slotted core •
Jelly filled •
Ribbon Fibers •
In compliance with IEC Specs •

INSTALLATION APPLICATION
Outdoor fiber optic cable for duct Telecommunication, Video, Data
installation in long distance and local Transmission, CATV, Long Distance,
area where high fiber counts are Backbone, Local Area Network
required, also suitable for indoor
applications. Easy handling and quick
Optional Constructions
installation. Time saving when splicing
1. Steel Wire Armored
with mass fusion splicers.
2. Steel Tape Armored
3. Light Weight Duct
TECHNICAL DATA 4. Light Weight Non-metallic
No of fibers : 4...576 5. Non-metallic Duct
Number of Slots : 6...12 6. Corrugated Steel Tape Armored
Number of Fiber/Ribbon : 4 or 8 7. Light Duty Aerial
Number of Ribbon/Slots : 1...6 8. Non-metallic Aerial (ADSS)
Nominal cable diameter (mm) : 13...28 9. Indoor
Nominal weight (kg/km) : 110...600
Min. Pulling Tension (Nt) : 1100
Min. Crush Strength(Nt/100 mm) : 3000
Permissible Bending Radius (mm)
During/After Installation : 260/140
Temperature Range
Operation : -40 oC to + 70 oC
Installation : -20 oC to + 70 oC

Note: Special designs upto 960 fibers capacity are available upon request.

FC.14.r1 - p.10
www.bmetenergy.com
CENTRAL TUBE OUTDOOR FIBER OPTIC CABLE

1. Optical Fiber (Colored)


2. Tube Filling Jelly
3. Central Loose Tube
4. Yarns
5. Inner PE Sheath
6. Corrugated Steel Tape
7. Outer PE Sheath

All MM and SM Fiber Types Available •


Outdoor type •
Central Tube Design •
Double PE Jacket •
Corrugated Steel Tape Armored •
Jelly filled Central Tube •
In compliance with IEC Specs •

INSTALLATION APPLICATION
Outdoor fiber optic cable with central tube Telecommunication, Video,
design to be used specially in local area Data Transmission, CATV
networks and inside the campus areas. Local Area Network (LAN)
These type of cables are used for duct
applications.
Optional Constructions
TECHNICAL DATA 1. Single Sheathed Corrugated
No of fibers : 1...12 Steel Tape Armored
Nominal cable diameter (mm) : 10 2. Single or Double Sheathed
Nominal weight (kg/km) : 80 Non-Metallic
Min. Pulling Tension (Nt) : 1100 3. Steel Wire Armored
Min. Crush Strength(Nt/100 mm) : 1500 4. HFFR PE or PVC Sheath
Permissible Bending Radius (mm)
During/After Installation : 250/130
Temperature Range
Operation : -40 oC to + 80 oC
Installation : -20 oC to + 70 oC

Note: Special designs upto 24 fibers capacity are available upon request.
Single mode, Multi Mode, Tight Coated fibers can be used in these design, as per
Customer’s requirements.

FC.14.r1 - p.11
www.bmetenergy.com
CENTRAL TUBE INDOOR FIBER OPTIC CABLE

1. Optical Fiber (Colored)


2. Tube Filling Jelly
3. Central Loose Tube
4. Yarns
5. Outer Sheath (PE, HFFR PE or PVC)

All MM and SM Fiber Types Available •


Indoor type •
Central Tube Design •
Single PE, HFFR PE or PVC Jacket •
Jelly Filled Tube •
In compliance with IEC Specs •

INSTALLATION APPLICATION
Indoor fiber optic cable with central tube Telecommunication, Video,
design and Flame Retardant/Halogen Free Data Transmission, CATV
(HFFR) outer sheaths or PVC Sheath to be Local Area Network (LAN)
used specially inside the buildings.

TECHNICAL DATA
No of fibers : 1...12
Nominal cable diameter (mm) : 8
Nominal weight (kg/km) : 50
Min. Pulling Tension (Nt) : 800
Min. Crush Strength(Nt/100 mm) : 1000
Permissible Bending Radius (mm)
During/After Installation : 160/80
Temperature Range
Operation : -40 oC to + 80 oC
Installation : -20 oC to + 70 oC

Note: Special designs upto 24 fibers capacity are available upon request.
Single mode, Multi Mode, Tight Coated fibers can be used in these designs,
as per Customer’s requirements.

FC.14.r1 - p.12
www.bmetenergy.com
INDOOR FIBER OPTIC CABLE

1. Central Strength Member (FRP)


2. Loose Buffer Tube (Colored)
3. Optical Fiber (Colored)
4. Thixotropic Jelly
5. Core Wrappings
6. Yarns
7. Outer Sheath (PE, HFFR PE or PVC)

All MM and SM Fiber Types Available •


Indoor type •
Multitube Structure •
Small Size, Light Weight •
Single PE, HFFR PE or PVC Jacket •
Jelly Filled Core Option •
In compliance with IEC Specs •

INSTALLATION APPLICATION
Indoor fiber optic cable with special Telecommunication, Video, Data
Flame Retardant/Halogen Free (HFFR) or Transmission, CATV, Long Distance,
PVC outer sheaths for indoor use inside Backbone, Local Area Network
the buildings and/or tunnels.

TECHNICAL DATA
No of fibers : 1...144
Number of Buffer tubes : 1...12
Number of fiber/buffer tubes : 1...12
Nominal cable diameter (mm) : 10...16
Nominal weight (kg/km) : 90...170
Min. Pulling Tension (Nt) : 1000
Min. Crush Strength(Nt/100 mm) : 1500
Permissible Bending Radius (mm)
During/After Installation : 200/100
Temperature Range
Operation : -40 oC to + 70 oC
Installation : -20 oC to + 70 oC

Note: Special designs upto 672 fibers capacity are available upon request.

FC.14.r1 - p.13
www.bmetenergy.com
STEEL TAPE ARMORED AERIAL FIBER OPTIC CABLE

A : PE Coating
B : Steel Wire Stranded Supporting Rope
C : Web
1. Central Strength Member (FRP) with PE coating
2. Loose Buffer Tube (Colored)
3. Optical Fiber (Colored)
4. Thixotropic Jelly
5. Core Wrappings
6. Yarns
7. Aluminium Foil
8. Inner PE Sheath
9. Bitumenized Crepe Paper
10. Steel Tape (2 Layers) Armoring
11. Outer PE Sheath

All MM and SM Fiber Types Available •


Outdoor type •
Multitube Structure •
Double PE Jacket •
Two Layers of Galvanized Steel Type Armoring •
Moisture barrier •
Jelly Filled Core Option •
Steel Wired Stranded Supporting Rope •
In compliance with IEC Specs •

INSTALLATION APPLICATION
Outdoor fiber optic cable for aerial installation with Telecommunication, Video, Data
heavy duty applications and where ballistic Transmission, CATV, Long
protection is also required. Special designs are Distance, Backbone, Local Area
available for pole span lengths more than 60 Network
meters.

TECHNICAL DATA
No of fibers : 1...144
Number of Buffer tubes : 1...12
Number of fiber/buffer tubes : 1...12
Nominal cable diameter (mm) : 15...23
Nominal weight (kg/km) : 440...750
Min. Pulling Tension (Nt) : 6000
Min. Crush Strength(Nt/100 mm) : 4000
Permissible Bending Radius (mm)
During/After Installation : 320/160
Temperature Range
Operation : -40 oC to + 70 oC
Installation : -20 oC to + 70 oC
Note: Special designs upto 288 fibers capacity are available upon request.

FC.14.r1 - p.14
www.bmetenergy.com
LIGHT DUTY AERIAL FIBER OPTIC CABLE

A.PE Coating
B. Steel Wire Stranded Supporting Rope
C. Web
1. Central Strength Member (FRP)
2. Loose Buffer Tube (Colored)
3. Optical Fiber (Colored)
4. Thixotropic Jelly
5. Core Wrappings
6. Yarns
7. Aluminium Foil
8. Outer PE Sheath
9. Filler
All MM and SM Fiber Types Available •
Outdoor type •
Light Weight •
Multitube Structure •
Single PE Jacket •
Moisture Barrier •
Jelly Filled Core Option •
Steel Wired Stranded Supporting Rope •
In compliance with IEC Specs •
INSTALLATION APPLICATION
Outdoor fiber optic cable for aerial Telecommunication, Video, Data
installations where ballistic protection is Transmission, CATV, Long Distance,
not required. Special designs are available Backbone, Local Area Network
for pole span lengths more than 60
meters.

TECHNICAL DATA
No of fibers : 1...144
Number of Buffer tubes : 1...12
Number of fiber/buffer tubes : 1...12
Nominal cable diameter (mm) : 12...20
Nominal weight (kg/km) : 250...460
Min. Pulling Tension (Nt) : 6000
Min. Crush Strength(Nt/100 mm) : 3000
Permissible Bending Radius (mm)
During/After Installation : 250/130
Temperature Range
Operation : -40 oC to + 70 oC
Installation : -20 oC to + 70 oC

Note: Special designs upto 288 fibers capacity are available upon request.
FC.14.r1 - p.15
www.bmetenergy.com
NON-METALLIC AERIAL FIBER OPTIC CABLE (ADSS)

1. Central Strength Member (FRP)


2. Loose Buffer Tube (Colored)
3. Optical Fiber (Colored)
4. Thixotropic Jelly
5. Core Wrappings
6. Inner PE Sheath
7. Layers of Yarns
8. Outer PE Sheath

All MM and SM Fiber Types Available •


Outdoor type •
Fully non-metallic •
Multitube structure •
Double PE jacket •
Non-metallic strength members •
In compliance with IEC Specs •

INSTALLATION APPLICATION
Outdoor fiber optic cable for aerial Telecommunication, Video, Data
installations upto 60 meters span length. Transmission, CATV, Long Distance,
Flexible light weight design where electro- Backbone, Local Area Network
magnetic and high voltage protections and
high voltage protections are required.
Special designs are available for longer
span lengths upto 500 meters.

TECHNICAL DATA
No of fibers : 1...144
Number of Buffer tubes : 1...12
Number of fiber/buffer tubes : 1...12
Nominal cable diameter (mm) : 14...22
Nominal weight (kg/km) : 160...370
Min. Pulling Tension (Nt) : 5000
Min. Crush Strength(Nt/100 mm) : 3500
Permissible Bending Radius (mm)
During/After Installation : 320/160
Temperature Range
Operation : -40 oC to + 70 oC
Installation : -20 oC to + 70 oC

Note: Special designs upto 288 fibers capacity are available upon request.
Spiral type installation materials can also be supplied upon requirest.

FC.14.r1 - p.16
www.bmetenergy.com
SELF SUPPORTING BALLISTIC PROTECTED
AERIAL FIBER OPTIC CABLE

1. Central Strength Member (FRP)


2. Loose Buffer Tube (Colored)
3. Optical Fiber (Colored)
4. Thixotropic Jelly
5. Petroleum Jelly
6. Core Wrappings
7. Aramid Yarns (1st Layer)
8. Inner PE Sheath
9. Aramid Yarns (2nd Layer)
10. Corrugated Steel Tape
11. Outer PE Sheath

All MM and SM Fiber Types Available •


Outdoor Aerial type •
Multitube structure •
Corrugated steel tape armored •
Ballistic Protected •
Dry Core Option •
In compliance with IEC Specs •

INSTALLATION APPLICATION
Outdoor fiber optic cable for aerial Telecommunication, Video, Data
installation where ballistic protection is Transmission, CATV, Long Distance,
required. Backbone, Local Area Network

TECHNICAL DATA
No of fibers : 1...144
Number of Buffer tubes : 1...12
Number of fiber/buffer tubes : 1...12
Nominal cable diameter (mm) : 17...21
Nominal weight (kg/km) : 290...480
Min. Pulling Tension (Nt) : 5000
Min. Crush Strength(Nt/100 mm) : 4000
Permissible Bending Radius (mm)
During/After Installation : 420/210
Temperature Range
Operation : -40 oC to + 70 oC
Installation : -20 oC to + 70 oC

Note: Special designs upto 288 fibers capacity are available upon request.

FC.14.r1 - p.17
www.bmetenergy.com
MULTITUBE RIVER CROSSING FIBER OPTIC CABLE

1. Petroleum Jelly
2. Loose Buffer Tube (Colored)
3. Tube Filling Jelly
4. Optical Fiber (Colored)
5. Central Strength Member (FRP)
6. Filler
7. Core Wrappings
8. Yarns
9. Aluminium Foil
10. First PE Sheath
11. Steel wires (1st layer)
12. Second PE Sheath
13. Steel wires (2nd layer)
14. Outer PE Sheath

All MM and SM Fiber Types Available •


River crossing type •
Multitube structure •
Multi PE Jacket •
Steel wire armored •
Jelly filled core •
Moisture Barrier •
In compliance with IEC Specs •

INSTALLATION APPLICATION
River crossing type fiber optic cable which Telecommunication, Video, Data
is used to cross the rivers and canals Transmission, CATV, Long Distance,
safely for more than 1000 meters in Backbone, Local Area Network
width.

TECHNICAL DATA
No of fibers : 1...144
Number of Buffer tubes : 1...12
Number of fiber/buffer tubes : 1...12
Nominal cable diameter (mm) : 21...28
Nominal weight (kg/km) : 700...1100
Min. Pulling Tension (Nt) : 25000
Min. Crush Strength(Nt/100 mm) : 10000
Permissible Bending Radius (mm)
During/After Installation : 840/420
Temperature Range
Operation : -40 oC to + 80 oC
Installation : -20 oC to + 70 oC

Note: Special designs upto 288 fibers capacity are available upon request.

FC.14.r1 - p.18
www.bmetenergy.com
MULTITUBE SUBMARINE FIBER OPTIC CABLE

1. Petroleum Jelly
2. Loose Buffer Tube (Colored)
3. Tube Filling Jelly
4. Optical Fiber (Colored)
5. Central Strength Member
6. PE Coating
7. Yarns
8. First PE Sheath
9. Steel wires (1 st layer)
10. Second PE Sheath
11. Aluminium foil
12. Third PE Sheath
13. Steel wires (2nd layer)
14. Outer PE Sheath

All MM and SM Fiber Types Available •


Submarine type •
Multitube structure •
Multi PE Jacket •
Double Steel wire armored •
Jelly filled core •
Moisture Barrier •
In compliance with IEC Specs •

INSTALLATION APPLICATION
Submarine fiber optic cabe to be installed Telecommunication, Video, Data
at shallow (Upto 100 mt.) sea conditions. Transmission, CATV, Long Distance,
These type of cables are used in sea, Backbone, Local Area Network
where anchoring and fishing activities
frequently occur.

TECHNICAL DATA
No of fibers : 1...144
Number of Buffer tubes : 1...12
Number of fiber/buffer tubes : 1...12
Nominal cable diameter (mm) : 25...36
Nominal weight (kg/km) : 1350...2400
Min. Pulling Tension (Nt) : 50000
Min. Crush Strength(Nt/100 mm) : 15000
Permissible Bending Radius (mm)
During/After Installation : 900/450
Temperature Range
Operation : -40 oC to + 80 oC
Installation : -20 oC to + 70 oC

Note: Special designs upto 288 fibers capacity are available upon request.

FC.14.r1 - p.19
www.bmetenergy.com
LIGHT WEIGHT(LW) TYPE SUBMARINE FIBER OPTIC CABLE

1. Tube Filling Jelly


2. Optical Fibers (Colored)
3. Central Buffer Tube
4. First PE Sheath
5. Metallic moisture Barrier/Conductor
6. Second PE Sheath
7. Steel Wire Armoring
8. Outer PE Sheath

All MM and SM Fiber Types Available •


Submarine type •
Central Tube structure •
Light Weight •
Multi PE Jacket •
Steel Wire Armored •
Moisture Barrier •
Jelly Filled Tube •
In Compliance with IEC Specs •

INSTALLATION APPLICATION
Submarine fiber optic cabe to be installed Telecommunication, Video, Data
in deep sea conditions where protection Transmission, CATV, Long Distance,
against fishing activities and anchoring is Backbone, Local Area Network
not required.

TECHNICAL DATA
No of fibers : 1...12
Nominal cable diameter (mm) : 15
Nominal weight (kg/km) : 450
Max. Pulling Tension (Nt) : 35000
Min. Crush Strength(Nt/100 mm) : 8000
Permissible Bending Radius (mm)
During/After Installation : 450/230
Temperature Range
Operation : -40 oC to + 80 oC
Installation : -20 oC to + 70 oC

Note: Special designs upto 24 fibers capacity are available upon request.

FC.14.r1 - p.20
www.bmetenergy.com
PROTECTED (SWP) TYPE SUBMARINE FIBER OPTIC CABLE

1. Tube Filling Jelly


2. Optical Fibers (Colored)
3. Central Buffer Tube
4. First HDPE Sheath
5. Metallic moisture Barrier/Conductor
6. Second PE Sheath
zzzz 7. Steel Wire Armoring (1st layer)
8. Third PE Sheath
9. Steel Wire Armoring (2nd layer)
10. PE Outer Sheath

All MM and SM Fiber Types Available •


Submarine Type •
Central Tube Structure •
Multi PE Jacket •
Steel Wire Armored •
Moisture Barrier •
Jelly Filled Tube •
In compliance with IEC Specs •

INSTALLATION APPLICATION
Submarine fiber optic cabe to be installed Telecommunication, Video, Data
in shallow sea conditions where heavy Transmission, CATV, Long Distance,
protection is required against fishing Backbone, Local Area Network
activities and anchoring.

TECHNICAL DATA
No of fibers : 1...12
Nominal cable diameter (mm) : 26
Nominal weight (kg/km) : 1100
Max. Pulling Tension (Nt) : 130000
Min. Crush Strength(Nt/100 mm) : 12000
Permissible Bending Radius (mm)
During/After Installation : 650/330
Temperature Range
Operation : -40 oC to + 80 oC
Installation : -20 oC to + 70 oC

Note: Special designs upto 24 fibers capacity are available upon request.

FC.14.r1 - p.21
www.bmetenergy.com
ANNEX-1: OPTICAL FIBER DATASHEETS

ITU-T G.652.B (Singlemode Fiber)


Physical Characteristics
Cladding Diameter 125,0 ± 0,7 µm
Cladding Non-Circularity ≤ 0,5 %
Core/Cladding Concentricity Error ≤ 0,5 µm
Coating Diameter (Colored/Uncolored) 250 ± 15 µm / 245 ± 10 µm
Coating/Cladding Concentricity Error ≤ 12 µm
Tensile Proof Test ≥ 1,0 %
Optical Characteristics
at 1310 nm ≤ 0,34 dB /km
at 1550 nm ≤ 0,21 dB /km
Attenuation
(Uncabled) Change in Attenuation vs
Temperature (-60 oC to +85 oC), at ≤ 0,05 dB /km
1310, 1550 and 1625 nm
at 1285-1330 nm ≤ 3,5 ps/nm•km
at 1550 nm ≤ 18,0 ps/nm•km
Chromatic Dispersion (CD)
Zero Dispersion Slope (S 0 ) ≤ 0,092 ps/(nm2•km)
Zero Dispersion Wavelength (λ 0 ) 1300-1324 nm
at 1310 nm 1.466
Index of Refraction (IOR)
at 1550 nm 1.467
at 1310 nm 9,2 ± 0,4 µm
Mode Field Diameter (MFD)
at 1550 nm 10,4 ± 0,5 µm
Polarization Mode Dispersion (PMD) Uncabled Fiber PMD Coefficient ≤ 0,20 ps/ √km
Cut-off Wavelength (λ CC ) ≤ 1260 nm

FC.14.r1 - p.22
www.bmetenergy.com
ANNEX-1: OPTICAL FIBER DATASHEETS
652.D (Low Water Peak Singlemode Fiber)
Physical Characteristics
Cladding Diameter 125,0 ± 0,7 µm
Cladding Non-Circularity ≤ 0,5 %
Core/Cladding Concentricity Error ≤ 0,5 µm
Coating Diameter (Colored/Uncolored) 250 ± 15 µm / 245 ± 10 µm
Coating/Cladding Concentricity Error ≤ 12 µm
Tensile Proof Test ≥ 1,0 %
Optical Characteristics
at 1310 nm ≤ 0,34 dB /km
Attenuation at 1383 nm ± 3 nm ≤ 0,33 dB /km
(Uncabled) at 1550 nm ≤ 0,20 dB /km
at 1625 nm ≤ 0,23 dB /km
at 1285-1330 nm ≤ 3,5 ps/nm•km
at 1550 nm ≤ 17,0 ps/nm•km
at 1625 nm ≤ 22,0 ps/nm•km
Chromatic Dispersion (CD)
Zero Dispersion Slope (S 0 ) ≤ 0,092 ps/nm2•km
Zero Dispersion Wavelength 1300-1324 nm
(λ 0 )
at 1310 nm 1.466
Index of Refraction (IOR)
at 1550 nm 1.467
at 1310 nm 9,2 ± 0,4 µm
Mode Field Diameter (MFD)
at 1550 nm 10,4 ± 0,5 µm
Polarization Mode Dispersion (PMD) Uncabled Fiber PMD Coefficient ≤ 0,20 ps/ √km
Cut-off Wavelength (λ CC ) ≤ 1260 nm

ITU-T G.653 (Dispersion Singlemode Fiber - DSF)


Characteristics Typical Value
Cladding Diameter 125 ± 1,0 µm
Attenuation at 1550 nm ≤ 0,22 dB / km
1525-1575 nm ≤ 3,5 ps/nm•km
Chromatic Dispersion (CD) Zero Dispersion Siope ≤ 0,085 ps/nm2•km
Zero Dispersion wavelength 1525-1575 nm
Mode Field Diameter (MFD) at 1550 nm 8,0 ± 0,5 µm
Polarization Mode Dispersion PMD) Uncabled Fiber PMD Coefficient ≤ 0,20 ps/ √km
Cut-off Wavelength (λ CC ) ≤ 1270 nm

FC.14.r1 - p.23
www.bmetenergy.com
ANNEX-1: OPTICAL FIBER DATASHEETS
ITU-T G.655 (Non-Zero Dispersion Shifted Singlemode Fiber - NZDSF)
Characteristics Typical Value
Application Bands C-L S-C-L
Cladding Diameter 125 ± 1,0 µm
Coating Diameter(Colored/Uncolored) 250 ± 15 µm / 245 ± 10 µm
Effective Area (A eff ) 72 mm2 95 mm2
at 1550 nm ≤ 0,22 dB/km
Attenuation
at 1625 nm ≤ 0,25 dB/km
at 1530-1565 nm 2,0 ~ 6,0 ps/nm•km 6,5 ~ 13,0 ps/nm•km
at 1565-1625 nm 4,5 ~ 11,2 ps/nm•km
Chromatic Dispersion
at 1460-1625 nm 2,0 ~ 16,5 ps/nm•km
2
Zero Dispersion Slope 0,09 ps/nm •km 0,07 ps/nm2•km
Index of Refraction (IOR) at 1550 nm 1470
Mode Field Diameter at 1550 nm 9,6 ± 0,4 µm
Uncabled Fiber PMD ≤ 0,20 ps/√km
Polarization Mode Dispersion (PMD)
Coefficient
Cut-off-Wavelength (cc) ≤ 1450 nm

ITU-T G.656
CWDM and DWDM throughout the region 1450-1625 nm (S-C-L Bands)
Characteristics Typical Value
Cladding Diameter 125 ± 1,0 µm
Coating Diameter 250 ± 15 µm
Effective Area (A eff ) 45 mm2
at 1460 nm ≤ 0,28 dB/km
Attenuation at 1550 nm ≤ 0,22 dB/km
at 1625 nm ≤ 0,25 dB/km
1460 - 1625 nm 2.0 ~ 8,0 ps/nm•km
Chromatic Dispersion 1530-1565 nm 40 ~ 7,0 p s/nm•km
Dispersion Slope at 1550 nm 0,092 ps/nm2•km
Polarization Mode Dispersion (PMD) ≤ 0,10 dB/km
Index of Refraction (IOR) at 1550 nm 1470
Mode Field Diameter at 1550 nm 7,7 ± 0,4 µm
Polarization Mode Dispersion (PMD) Uncabled Fiber PMD Coefficient ≤ 0,20 ps/ √km
Cut-off Wavelength (λ CC ) ≤ 1450 nm

FC.14.r1 - p.24
www.bmetenergy.com
ANNEX-1: OPTICAL FIBER DATASHEETS

ITU-T G.657 A/B


A B
Mode Field Diameter Wavelength 1350 nm 1310 nm
Range of nominal values 8,6 ~ 9,5 µm ± 0,4 µm 6,3 ~ 9,5 µm ± 0,4 µm
Cladding Diameter Nomial 1250 µm ± 0,7 ± µm 125,0 µm ± 0,7 ± µm
Core Concentricity Error Maximum ≤ 0,5 µm ≤ 0,5 µm
Cladding Non-Circularity Maximum ≤ 1,0 % ≤ 1,0 %
Cable Cut-off Wavelength Maximum 1260 nm 1260 nm
A1 A2 B2 B3
Radius (mm) 15 10 15 10 7,5 15 10 7,5 10 7,5 5
Uncabled Fiber
Number of turns 10 1 10 1 1 10 1 1 1 1 1
Macrobending Loss
Max. At 1550nm (dB) 0,25 0,75 0,03 0,1 0,5 0,03 0,1 0,5 0,03 0,08 0.15
Max. At 1620nm (dB) 1.0 1,5 0,1 0,2 1,0 0,1 0,2 1,0 0,1 0,25 0,45
Proof Stress Minimum 0,69 Gpa
λ 0min 1300 nm 1250 nm
Chromatic Dispersion
λ 0max 1324 nm 1350 nm
Coefficient 2 2
S 0max 0,092 ps/nm x km 0,11 ps/nm x km
≤ 0,4 dB/km
≤ 0,4 dB/km Max. At 1310nm
Max. from 1310nm to 1625 nm
≤ 0,4 dB/km
Auttenuation Coefficient ≤ 0,4 dB/km Max. At 1550nm
Max. at 1383nm ± 3nm
≤ 0,3 dB/km
≤ 0,3 dB/km Max. At 1625nm
Max.at 1550nm
Pmd Coefficient Maximum PMD Q 0,20 ps/√km 0,50 √km
at 1310 nm 1.466
Index of Refraction (IOR)
at 1550 nm 1.467

FC.14.r1 - p.25
www.bmetenergy.com
ANNEX-1: OPTICAL FIBER DATASHEETS

MM62.5 (OM 1)
Parameters Typical Value
Core Diameter 62,5 ± 3,0 µm
Cladding Diameter 125 ± 2,0 µm
Coating Diameter 250 ± 15 µm
Core Concentricity Error ≤ 3 µm
Cladding Non-Circularity ≤2%
Numerical Aperture 0,275 ± 0,015
at 850 nm ≤ 3,0 dB / km
Attenuation
at 1300 nm ≤ 0,7 dB / km
at 850 nm ≥ 200 MHz•km
Bandwidth
at 1300 nm ≥ 500 MHz•km
at 850 nm 1.496
Index of Refraction (IOR)
at 1300 nm 1.491

MM50 (OM 2)
Parameters Typical Value
Core Diameter 50 ± 3.0 µm
Cladding Diameter 125 ± 2,0 µm
Coating Diameter 250 ± 15 µm
Core Concentricity Error ≤ 3 µm
Cladding Non-Circularity ≤2%
Numerical Aperture 0,20 ± 0,015 µm
at 850 nm ≤ 2,5 dB / km
Attenuation
at 1300 nm ≤ 0.7 dB / km
at 850 nm ≥ 500 MHz•km
Bandwidth
at 1300 nm ≥ 500 MHz•km
at 850 nm 1.483
Index of Refraction (IOR)
at 1300 nm 1.479

MM50 (OM 2+)


Parameters Typical Value
Core Diameter 50 ± 3,0 µm
Cladding Diameter 125 ± 2,0 µm
Coating Diameter 250 ± 15 µm
Core Concentricity Error ≤ 3 µm
Cladding Non-Circularity ≤2%
Numerical Aperture 0,20 ± 0,015 µm
at 850 nm ≤ 2,5 dB / km
Attenuation
at 1300 nm ≤ 0,7 dB / km
at 850 nm ≥ 700 MHz•km
Bandwidth
at 1300 nm ≥ 500 MHz•km
at 850 nm ≥ 950 MHz•km
Effective Modal Bandwidth (EMB)
at 1300 nm ≥ 500 MHz•km
at 850 nm 1.483
Index of Refraction (IOR)
at 1300 nm 1.479

FC.14.r1 - p.26
www.bmetenergy.com
ANNEX-1: OPTICAL FIBER DATASHEETS

MM50 (OM 3)
Parameters Typical Value
Core Diameter 50 ± 3,0 µm
Cladding Diameter 125 ± 2,0 µm
Coating Diameter 250 ± 15 µm
Core Concentricity Error ≤ 3 µm
Cladding Non-Circularity ≤2%
Numerical Aperture 0,20 ± 0,015 µm
at 850 nm ≤ 2,5 dB / km
Attenuation
at 1300 nm ≤ 0,7 dB / km
at 850 nm ≥ 1500 MHz•km
Bandwidth
at 1300 nm ≥ 500 MHz•km
at 850 nm ≥ 2000 MHz•km
Effective Modal Bandwidth (EMB)
at 1300 nm ≥ 500 MHz•km
at 850 nm 1.483
Index of Refraction (IOR)
at 1300 nm 1.479

MM50 (OM 4)
Parameters Typical Value
Core Diameter 50 ± 3,0 µm
Cladding Diameter 125 ± 2,0 µm
Coating Diameter 250 ± 15 µm
Core Concentricity Error ≤ 3 µm
Cladding Non-Circularity ≤2%
Numerical Aperture 0,20 ± 0,015 µm
at 850 nm ≤ 2,5 dB / km
Attenuation
at 1300 nm ≤ 0,7 dB / km
at 850 nm ≥ 3500 MHz•km
Bandwidth
at 1300 nm ≥ 500 MHz•km
at 850 nm ≥ 4700 MHz•km
Effective Modal Bandwidth (EMB)
at 1300 nm ≥ 500 MHz•km
at 850 nm 1.483
Index of Refraction (IOR)
at 1300 nm 1.479

FC.14.r1 - p.27
www.bmetenergy.com
ANNEX-2: COLOR CODE

FIBER AND BUFFER TUBE COLOR CODE ACCORDING TO IEC 304


Fiber Fiber Ral Nr. Buffer Buffer Type Buffer Color Ral Nr. Type Of Fiber
Number Color Number
1 Red 3000 1 Counter Buffer Red 3020
2 Green 6018 2 Direction Buffer Green 6018
3 Blue 5015 3 Following Buffers White 9016 For SM Fibres
4 Yellow 1021 Bright Green 6019 For MM 50/125
5 White 9010 Bule 5015 For MM62,5/125
6 Grey 7000 Filler Black 9005
7 Brown 8003
8 Violet 4005
9 Turquoise 6027
10 Black 9005
11 Orange 2008
12 Pink 3015

FIBER AND BUFFER TUBE COLOR CODE ACCORDING TO (ANSI / TIA / EIA598-A)
Fiber / Buffer Fiber / Buffer Fiber / Buffer Fiber / Buffer
Number Color Number Color and Tracer
1 Blue 13 Blue with Black Tracer
2 Orange 14 Orange with Black Tracer
3 Green 15 Green with Black Tracer
4 Brown 16 Brown with Black Tracer
5 Slate 17 Slate with Black Tracer
6 White 18 White with Black Tracer
7 Red 19 Red with Black Tracer
8 Black 20 Black with YellowTracer
9 Yellow 21 Yellow with Black Tracer
10 Violet 22 Violet with Black Tracer
11 Rose 23 Rose with Black Tracer
12 Aqua 24 Aqua with Black Tracer

FC.14.r1 - p.28
www.bmetenergy.com
ANNEX-3: OPTICAL BANDS

O E S C L U

0,7 0,8 0,9 1,0 1,1 1,2 1,3 1,4 1,5 1,6 1,7

OPTICAL BANDS
BAND WAVELENGTH
WINDOW
NAME (µm)
0,82 – 0,88 1 st
O Original Band 1,26 – 1,36 2 nd
E Extended Band 1,36 – 1,46
S Short Band 1,46 – 1,53
C Convensional Band 1,53 – 1,565 3 rd
L Long Band 1,65 – 1,625
U Ultra Long Band 1,625 – 1,675

FC.14.r1 - p.29
www.bmetenergy.com
FC.14.r1 - p.30
www.bmetenergy.com

You might also like