Tensile Test Report
Tensile Test Report
Tensile Test Report
Done by:
1- Abdulmalek Mohammed Al-shameri
(36/20140)
2- Hesham Fuad Al-qataberi
(71/2014)
3- Mohammed M. Ahmed Al-sanabani
(73/2014)
4- Tameem Rasheed Al-absi
(281/2014)
5- Saif Saleh Ali
(42/2014)
6- Yousif Abdo Qasim Al-helaly
(69/2014)
7- Hashem Fuad Anam
(72/2014)
8- Ammar Al-mehrabi
9- Waleed Hatem
Instructor: Prof. Khalil Al-hatab
Objectives:
To gain the principle of a uniaxial tensile testing and gain their practices on operating the tensile testing
machine to achieve the required tensile properties.
The tensile testing is carried out by applying longitudinal or axial load at a specific extension rate to a standard
tensile specimen with known dimensions (gauge length and cross sectional area perpendicular to the load direction) till
failure. The applied tensile load and extension are recorded during the test for the calculation of stress and strain. A range
of universal standards provided by Professional societies such as American Society of Testing and Materials (ASTM),
British standard, JIS standard and DIN standard provides testing are selected based on preferential uses. Each standard may
contain a variety of test standards suitable for different materials, dimensions and fabrication history.
A standard specimen is prepared in a round or a square section along the gauge length as shown in figures 1 a)
and b) respectively, depending on the standard used. Both ends of the specimens should have sufficient length and a
surface condition such that they are firmly gripped during testing. The initial gauge length Lo is standardized (in several
countries) and varies with the diameter (Do) or the cross-sectional area (Ao) of the specimen. This is because if the gauge
length is too long, the % elongation might be underestimated in this case. Any heat treatments should be applied on to the
specimen prior to machining to produce the final specimen readily for testing. This has been done to prevent surface oxide
scales that might act as stress concentration which might subsequently affect the final tensile properties due to premature
failure.