Service Manual Minisplits GOOD R410
Service Manual Minisplits GOOD R410
Service Manual Minisplits GOOD R410
Models
Indoor unit Outdoor unit
4MWW1512A9000AA 4TWK1512A9000AA
4MWW1512A1000AA 4TWK1512A1000AA
4MWW1518A1000AA 4TWK1518A1000AA
4MWW1524A1000AA 4TWK1524A1000AA
4MWW1530A1000AA 4TWK1530A1000AA
CONTENTS
1. IMPORTANT NOTICE
2. PRODUCT DIMENSIONS
3. REFRIGERATION CYCLE DIAGRAM
4. OPERATION DETAILS
5. WIRING DIAGRAM
6. EXPLOSION VIEW AND PART LISTS
7. PRECAUTION
8. NAMES OF PARTS
9. INSTALLATION
10. TROUBLE SHOOTING
Air Conditioner Service Manual
1. IMPORTANT NOTICE
This service manual is intended for use by individuals possessing adequate
backgrounds of electrical, electronic and mechanical experience. Any
attempt to repair the appliance may result in personal injury and property
damage. The manufacturer or seller cannot be responsible for the
interpretation of this information, nor can it assume any liability in
connection with its use.
The information, specifications and parameters are subject to change due to
technical modification or improvement without any prior notice. The
accurate specifications are presented on the nameplate label.
How to order spare parts
To have your order filled promptly and correctly, please finish the following
information:
6 Model No. with Indoor or Outdoor
7 Part No. in the Explosion View
8 Part Name
9 The quantity you needed
1
Air Conditioner Service Manual
2. PRODUCT DIMENSIONS
Indoor Unit:
Model A B C
2
Air Conditioner Service Manual
Outdoor Unit:
Model D E F G H I J K
3
Air Conditioner Service Manual
Liquid side
Gas side
3-way valve
Accumulator
Compressor
Heat pump
2-way valve
Capillary Assembly
Gas side
3-way valve
4-way valve
Accumulator Heating
Compressor Cooling
4
Air Conditioner Service Manual
4.Operation Details
Remote controller
The outlooking and some function of remote control may vary according
to the model.
The shape and position of buttons and indicators may vary according to
the model, but their function is the same.
The unit confirms the correct reception of each press button with a beep.
Functions of horizontal swing and health are optional.
5
Air Conditioner Service Manual
In cooling mode,press this button ,the temperature will increase 2 on the base of
setting temperature
10 ECO
In heating mode, press this button, the temperature will decrease 2 on the base of
setting temperature
Press this button to activate / deactivate the Super function which enables the unit to
reach the preset temperature in the shortest time.
12 TURBO In COOL mode, the unit will give the maximum cooling temperature with 16 ,high fan
speed.
In HEAT ode, the unit will give the maximum heating temperature with 31 ,high fan
speed.
To switch active /deactive "I FEEL" function.The air conditioner will regulate the room
13 I FEEL temperature based on the temperature(0 ~50 ) around the remote controller.This
function will terminate 2 hours later once it's active.
When you press the buttons "MODE" and "TIMER" at the same time, the remote
14 LOCK/UNLOCK controller will be locked, all buttons of the remote controller will be deactive
and it displays "Lo" .You can operate again as the same way to unlock the remote
contoller.
6
Air Conditioner Service Manual
Electronic controller
NOTES:
RT-------Room Temperature.
IPT------Indoor Pipe Temperature.
ST------indoor Setting Temperature.
OPT---Outdoor Pipe Temperature.
CRT---Compensated Room Temperature
1. Automatic mode
1) The initial RT determines A/C working mode and the setting temperature (ST), the mode is
determined effective only once unless A/C shut-down and then re-started. If from other mode
switches to automatic mode (including mode conversion after shutdown), it should be that the
compress stop more than 3 min then temperature judgment and automatic mode are conducted (it
can conduct immediately from fan mode switched to automatic, the indoor fan stops, three minutes
later the response is made and start up). Within 3 min, the output as: Showing the room
temperature, indoor fans starts (or anti-cold airflow), the outdoor fan stops;
With auto re‐start controller, once being turned off or in case of an accidently power cut, the A/C is able to
retain and restore the original mode when being turned on or the power supply is resumed, if the auto
restart function activated. power‐off after power‐on; while if the auto restart function isn’t activated,
the A/C enters standby state.
Heat pump
Mode Initial RT Initial ST
Cooling RT≥26°C 23°C
Dry 26°C>RT≥20°C 7°C
Heating RT<20°C 23°C
Cooling-only
Mode Initial RT Initial ST
Cooling RT≥26°C 23°C
Dry 26°C>RT≥20°C 7°C
Ventilating RT<20°C -
Under automatic mode (including from automatic converted into Dry mode), when A/C received the
temperature UP or DOWN signals from the remote controller, the setting temperature (ST) adjusts
correspondingly to the current room temperature plus or minus 1°C, the automatic regulating
temperature range is ± 2°C.
2. Cooling mode
1) The control of the compressor
a. When RT-ST≥1°C,the compressor is running.
b. When RT-ST<-1°C,the compressor stops.
c. When-1°C≤RT-ST<1°C, the compressor keeps its original state.
2) Outdoor fan motor and the compressor run simultaneously (except for defrosting).
3) The control of indoor fan motor:
a. Indoor fan motor can operate by automatic, low, middle, or high airflow speed circularly.
7
Air Conditioner Service Manual
b. Indoor fan motor automatic airflow speed control, it works as shown in Figure 1:
Hi
Mid
Lo
RT-ST
1°C 2°C 4°C
Figure 1 Cooling automatic airflow
When the temperature changing leads the fan speed variation, the switch can only be made orderly,
and in every grade of air flow speed should run 1 minute at least.
3. Dry mode
While select to this mode, the air conditioner operates for 3 minutes according to cooling mode firstly
(ST set at 7°C), and then takes the detected backflow air temperature minus 2°C as a new set
temperature (the lowest temperature: 5°C) and runs according to cooling mode, indoor fan operates at
low-speed, at this moment the setting operation of fan speed invalid but Swing adjustable.
4. Heating mode
On the Heating mode, the room temperature (RT) is compensated (CRT), a fter that, the room
temperature displayed on the LED is CRT=RT-3°C.
1) The control of the compressor
a. When ST-CRT≥1°C,the compressor is running.
b. When ST-CRT<-1°C,the compressor stops.
c. When -1°C≤ST-CRT<1°C, the compressor keeps its original state
2) Outdoor fan motor and the compressor run simultaneously (except for defrosting)
3) The control of indoor fan motor:
a. Indoor fan motor can operate by automatic, low, middle, or high airflow speed circularly.
b. Indoor fan motor automatic airflow speed control, it works as shown in Figure 2:
Hi
Mid
Lo
ST-CRT 1°C 2°C 4°C
When the temperature changing leads the fan speed variation, the switch can only be made orderly,
and every grade of air flow speed should run 1 minute at least.
4) Vane motor control: run as set state.
5) 4-way valve control:
a. Under heating mode, the four-way valve maintains well-connected status (including the
compressor stops on set condition, except for the defrosting process)
b. When the mode switches into the heating mode or A/C start-up, four-way valves will open 5
Seconds before the compressor starts; while the mode exits from the heating mode or A/C turn off,
the four-way valve will close 2min later after shut-down the compressor.
8
Air Conditioner Service Manual
6) Defrosting function:
During defrosting, once mode changing, economic operation or temperature setting signals received, the
buzzer and display will make response immediately, but the other operations won’t implement until
defrosting finished;
During defrosting, the signals of On-Off, Timing, Sleep, Fan speed and/or Swing can respond, but the
Fan speed and/or Swing should be in accordance with operation for Cold Air Prevention.
Except the above signal processing during defrosting, no other signals will deal with, only a voice of
buzz for response.
During defrosting, electrical heating (optional function) stops compulsively.
Figure 3
Condition 2: When running time is more than or equal to 120 min (compressor is running
accumulatively), the indoor temperature is less than 35°C for 2 min sustained. Running into defrosting
under condition 2, defrosting time set is 8 min.
Condition 3: After the compressor is operating for 20min continuously, the indoor pipe temperature is
less than 23°C (cold air prevention wind temperature) when the fan stops running (including
temperature dropping when compressor operating, not including the compressor’s starting up course),
and the machine runs into defrosting according to any one condition as below.
9
Air Conditioner Service Manual
Outdoor Fan
ON ON
OFF
4-way Valve
ON ON
OFF
10
Air Conditioner Service Manual
5. Fan mode
1) Indoor fan motor is running at setting speed (the speed same as heating mode).
2) Vane motor control: running according to the setting condition.
3) The outdoor unit doesn’t work under fan mode.
6. Sleeping mode
1) Under sleep mode, the indoor fan motor running at low speed, except the power light and sleep light
are ON, timer lights ON/OFF according to the setting state, running light OFF. LED will be OFF after
displaying 30S.
2) Temperature control:
6 (1) While changing from Cool mode to Sleep mode, one hour later, the operation Temp.=ST+1°C,
another one hour later, the operation Temp.=ST+2°C,after then the temperature has no changed
anymore.
7(2) When changing from Heating mode to Sleep mode, one hour later, the operation Temp.= ST‐1°C,
another one hour later, the operation Temp.=ST‐2°C,after then no changed anymore.
3) The machine will automatically shut up after running 10 hours under sleep mode.
When Timer ON and Sleep mode are implemented at the same time, the Sleep mode can not be
functioned.
7. Timer function
The timer can preset between 10min to 24h, when the time set less than “10” hours, the displayed time
shown by 0.5 hour as the unit, when the time set more than or equal to “10” hours, the displayed time
shown by 1 hour as the unit.
11
Air Conditioner Service Manual
9. Auto-restart function
1) The PCB retains the setting parameters in case of power off. When the power supply is resumed,
the machine, which has been started up the power-off memory function, is able to restore into the
original running state automatically.
To press the emergency button and power on the unit, and hold on for10 seconds, The buzzer
2) will ring three times, after this operation, the auto restart function activated.
3) To close auto restart function while it is activated, repeat process as above 2), the buzzer will ring
four times.
10.1 Protection
1) Compressor’s protection:
a. The PCB which with Auto-restart function, once it is activated, the compressor goes along 3min
delay protection when power on, otherwise the compressor without this protection even when the PCB
is power-on.
b . The compressor’s 3 min interval protection: the compressor can’t start-up until it stops 3 min later.
(except for the defrosting process).
c. .After the compressor started, it’s operation state remains the same within 3 min even when ST, RT variation.
b. When the indoor fan motor running at a low-speed under cold air prevention operation, once
12
Air Conditioner Service Manual
auxiliary electric heating works, the vane immediately withdraws from the cold air prevention location
and turn back to normal vane angle. While auxiliary electric heating stops, indoor fan motor goes on to
run at low-speed accordingly, the vane turns to cold air prevention location
Temperature dropping
34°C 32°
Temperature rising
27°
25°C
23°C
Stop the fan motor Stop the fan motor
While failure happens, the code displayed statically, if there are several failure codes reported at the
same time, then failure codes appears by turns every eight seconds correspondingly.
6 a. Sensor’s failure protection: when the sensor tested temperature out of the range ---
50°C≤T≤110°C, sensor failure is determined.
Once RT and/or IPT sensor failure appears, the compressor stops, and indoor and outdoor fan motors
shut off. Remote controller doesn’t response to any signal except for shutdown. During failure the
machine can run in fan mode. After the failure is settled, the PCB restores to standby status.
7 b. Failure protection of Indoor PG fan motor: If there is no feedback signal of rotated speed within 5s,
the indoor fan motor stops, meanwhile, the compressor, outdoor fan motor, four-way valve and/or
auxiliary electric heater etc. also cut down.
The indoor fan motor restarts again 10 seconds later, if still there is no feedback signal of rotated speed
within 5 seconds, the A/C stops and goes into indoor fan motor failure protection, buzzer rings three
times, and running light flashes at 6 times per 8 seconds. Once there is feedback signal while the failure
recovery, the failure will relieve automatically.
13
Air Conditioner Service Manual
5. WIRING DIAGRAM
INDOOR UNIT: 4MWW1512A9000AA 4MWW1512A1000AA
4MWW1518A1000AA
14
Air Conditioner Service Manual
OUTDOOR UNIT: 4TWK1524A1000AA
15
Air Conditioner Service Manual
FM
MDC
FM
SM SM SM
OUTDOOR UNIT: 4TWK1530A1000AA
16
Air Conditioner Service Manual
17
Air Conditioner Service Manual
18
Air Conditioner Service Manual
1
2
3 23
4
5 22
6 21
7
8 20
9
19
10
18
11
17
12
16
15
14
13
19
Air Conditioner Service Manual
20
Air Conditioner Service Manual
7 6 5 4 3 2 1
27
26
25
24
23
22
21
20
19
18
17
10 11 12 13 14 15 16
21
Air Conditioner Service Manual
2 Top Cover 1
3 Condenser 1
4 Outdoor Motor Supporter 1
5 Outdoor Motor 1
6 Propeller Fan 1
7 Left Grille Supporter 1
8 Front Plate 1
9 Fan Guard 1
10 Compressor 1
11 4-way Valve 1
12 4-way Valve Assembly 1
13 Base 1
14 Right Plate 1
15 Two-way Valve 1
16 Valve Supporter 1
17 Three-way Valve 1
18 Electrical Box Cover 1
19 Cable Clamp(φ6) 1
20 Cable Clamp(φ8) 1
21 Terminal 1
22 Fan Motor Capacitor 1
23 Compressor Capacitor 1
24 Capacitor Strip 1
25 Electrical Parts Box 1
26 Capillary Assembly 1
27 Partition plate 1
28 Base Carton 1
29 Base Forming 1 Not shown in the
Explosion view.
30 Cabinet Carton 1
31 Cover Forming 1
22
Air Conditioner Service Manual
OUTOOR UNIT: 4TWK1524A1000AA 4TWK1530A1000AA
6 5 3 2 1
27
26
25
24
23
22
21
20
19
18
17
10 11 12 13 14 15 16
23
Air Conditioner Service Manual
OUTOOR UNIT: 4TWK1524A1000AA 4TWK1530A1000AA
No. Part No. Part Name Q’ty Remark
1 Grille 1 Optional
2 Top Cover 1
3 Condenser 1
4 Outdoor Motor Supporter 1
5 Outdoor Motor 1
6 Propeller Fan 1
7 Left Grille Supporter 1
8 Front Plate 1
9 Fan Guad 1
10 Compressor 1
11 4-way Valve 1
12 4-way Valve Assembly 1
13 Base 1
14 Right Plate 1
15 Two-way Valve 1
16 Valve Supporter 1
17 Three-way Valve 1
18 Electrical Box Cover 1
19 Cable Clamp 2
20 Terminal 1
21 Fan Motor Capacitor 1
22 Compressor Capacitor 1
23 Capacitor Strip 1
24 Electrical Parts Box 1
25 AC Contactor 1
26 Capillary Assembly 1
27 Partition plate 1
28 Base Carton 1
29 Lower Foaming 1 Not show in the
30 Cabinet Carton 1 explosion
31 Upper Cover 1
24
Air Conditioner Service Manual
7.Precaution
7.1 SAFETY RULES AND RECOMMENDATIONS FOR THE INSTALLATION
Read this guide before installing and using the appliance.
During the installation of the indoor and outdoor units the access to the working area should
be forbidden to children.
Unforeseeable accidents could happen.
Make sure that the base of the outdoor unit is firmly fixed.
Check that air cannot enter the refrigerant system and check for refrigerant leaks when
moving the air conditioner.
Check that air cannot enter the refrigerant system and check for refrigerant leaks when
moving the air conditioner.
The ratings of the fuse installed in the built in-control unit are T 5A / 250V.
The user must protect the indoor unit with a fuse of suitable capacity for the maximum input
current or with another overload protection device.
Ensure that the mains voltage corresponds to that stamped on the rating plate. Keep the switch or
power plug clean. Insert the power plug correctly and firmly into the socket, thereby avoiding the
risk of electric shock or fire due to insufficient contact.
Check that the socket is suitable for the plug, otherwise have the socket changed.
The appliance must be fitted with means for disconnection from the supply mains having a contact
separation in all poles that provide full disconnection under over voltage category III conditions, and
these means must be incorporated in the fixed wiring in accordance with the wiring rules.
The air conditioner must be installed by professional or qualified persons. Do not install the appliance
at a distance of less than 50 cm from inflammable substances (alcohol, etc.) Or from pressurized
containers (e.g. spray cans).
If the appliance is used in areas without the possibility of ventilation, precautions must be taken to
prevent any leaks of refrigerant gas from remaining in the environment and creating a danger of fire.
The packaging materials are recyclable and should be disposed of in the separate waste bins .Take
the air conditioner at the end of its useful life to a special waste collection center for disposal.
Only use the air conditioner as instructed in this booklet. These instructions are not intended to cover every
possible condition and situation. As with any electrical household appliance, common sense and caution are
therefore always recommended for installation, operation and maintenance.
The appliance must be installed in accordance with applicable national regulations.
Before accessing the terminals, all the power circuits must be disconnected from the power supply.
25
Air Conditioner Service Manual
Have repairs carried out only by an authoritative Service Centre of the manufacturer. Incorrect
repair could expose the user to the risk of electric shock, etc.
Unhook the automatic switch if you foresee not to use the device for a long
time. The airflow direction must be properly adjusted.
The flaps must be directed downwards in the heating mode and upwards in the cooling mode.
Only use the air conditioner as instructed in this booklet. These instructions are not in ended to cover
every possible condition and situation. As with any electrical household appliance, common sense and
caution are therefore always recommended for installation, operation and maintenance.
26
Air Conditioner Service Manual
8.Names of parts
INDOOR UNIT
Indoor unit
1 2-3 4 No. Na
1 Front panel
2 Air filter
3 Special filter(option)
4 Display PCB
5 Vertical vane
6 Horizontal vane
6 5 7 Remote controller
7
8
Outdoor unit
No. Name
8 Air outlet grille
9 Electronic box cover
9
10 2-way valve
11 3-way valve
10
11
OUTD OOR UNIT
27
Air Conditioner Service Manual
9. Installation manual
9.1 Installation Details
Connecting pipe length
Pipe size(Inch)
Model
Liquid Gas
4MWW1512A9000AA/4TWK1512A9000AA 1/4 3/8
4MWW1512A1000AA/4TWK1512A1000AA 1/4 3/8
4MWW1518A1000AA/4TWK1518A1000AA 1/4 1/2
4MWW1524A1000AA/4TWK1524A1000AA 1/4 5/8
4MWW1530A1000AA/4TWK1530A1000AA 1/4 5/8
Pipe l ength is
Pi pe length is 15 meters Max.
15 meters Max.
be l ess than 5m
Indoor unit
Height should
be less tha n 5m
Height sh ould
Outdoor unit
;
Refrigerant piping
Max. length: m Additional refrigerant
Model Standard length: m
Calculation: ×g=20g/m(A-5m)
A
4MWW1512A9000AA/4TWK1512A9000AA 3.5 15 20g/m
4MWW1512A1000AA/4TWK1512A1000AA 3.5 15 20g/m
4MWW1518A1000AA/4TWK1518A1000AA 5.0 15 30g/m
4MWW1524A1000AA/4TWK1524A1000AA 5.0 15 30g/m
4MWW1530A1000AA/4TWK1530A1000AA 5.0 15 30g/m
Connecting cables
The power cord should be selected according to the following specifications sheet.
Appliance Amps Wire Size
5 AWG21/0.75 mm2
10 AWG18/1.0 mm2
13 AWG15 /1. 5 mm2
18 AWG14/1.6 mm2
25 AWG12/2.0 mm2
30 AWG10/2.5 mm2
28
Air Conditioner Service Manual
150mm
over the room. Mounting plate
Do not install the unit near a source of heat,
150mm
heat, steam or flammable gas.
Do not install the unit in too windy or dusty 150mm
places.
Do not install the unit where people often
pass. Select a place where the air condensed water drain pip e
discharge and operating sound level will Sleeve
not disturb the neighbors. insulatin g covering
Install the unit where connection between electrica l cable
indoor and outdoor unit is as easy as
possible. water dra in pipe
Install the unit where it is easy to drain the
condensed water.
Check the machine operation regularly and
leave the necessary spaces as shown in the
picture.
Install the indoor unit where the filter can
Minimum space to be left (mm) showing in the
be easily accessible.
picture.
OUTDOOR UNIT
Do not install the outdoor unit near sources of
heat, steam or flammable gas.
Do not install the unit in too windy or dusty
500mm
places.
Do not install the unit where people often
pass. Select a place where the air
discharge and operating sound level will
not disturb the neighbors.
Avoid installing the unit where it will be
exposed to direct sunlight (other wise use a
300mm
protection, if necessary, that should not 300
interfere with the air flow). mm
Leave the spaces as shown in the picture
for
The air to circulate freely. 500
200 mm
Install the outdoor unit in a safe and solid 0 mm
place.
If the outdoor unit is subject to vibration,
place rubber gaskets onto the feet of the
unit.
29
Air Conditioner Service Manual
30
Air Conditioner Service Manual
3).Do not bend the drain hose or leave it
protruding or twisted and do not put the end
of it in water. If an extension is connected to
the drain hose, ensure that it is lagged when
it passes into the indoor unit.
NO NO
31
Air Conditioner Service Manual
4).If the piping is installed to the right, the pipes,
power cable and drain hose must be lagged and
secured onto the rear of the unit with a pipe
connection.
Insert the pipe connection into the relative
slot.
Press to join the pipe connection to the
base.
9.2.8 Electronic connections Wiring diagram on the back of the cover
1. Take the cover away.
2. Connect the cable wires to the terminal
board using the same numbering as in the
32
Air Conditioner Service Manual
36