Location via proxy:   [ UP ]  
[Report a bug]   [Manage cookies]                
Download as pdf or txt
Download as pdf or txt
You are on page 1of 34

Warewashing

Hood-type dishwashers
Ecomax / Ecomax+
H 604 / 614 / 615
Installation and EN
Operation Manual
(Original Operation Manual)

DSN: AM-14-02 / AMB-14-03


From: 865730001 / 865770001 28. Nov. 2019
EN Ecomax / Ecomax+ Installation and Operation Manual

Table of Contents

1 Notes on the documentation 4


1.1 Application 4
1.2 Layout of the documentation 4
1.3 Symbols used 4

2 Safety instructions and regulations 5


2.1 Hazard levels 5
2.2 Layout of safety instructions 5
2.3 Basic safety instructions 5
2.4 Property damage 7

3 Product description 7
3.1 Intended purpose 7
3.2 Designation 8
3.3 Technical specifications 8

4 Controls 8

5 Installation 9
5.1 Personnel qualification 9
5.2 Special safety instructions 9
5.3 Transporting to the installation location 10
5.4 Removing the packaging 10
5.5 Installing the machine 10
5.6 Connecting to the power supply 11
5.7 Connecting the water 11
5.8 Connecting the drain 12
5.9 Connecting the dispenser 12

6 Commissioning 14
6.1 Personnel qualification 14
6.2 Special safety instructions 14
6.3 Setting the water hardness (optional) 14
6.4 Filling the salt reservoir (optional) 14
6.5 Filling chemical hoses 15

7 Operation 16
7.1 Personnel qualification 16
7.2 Special safety instructions 16
7.3 Preparations for washing 16
7.4 Displaying and selecting the program 17
7.5 Washing 18
7.6 Switch off machine 18
7.7 Executing daily cleaning 19

2 0000000286-001-EN / 28. Nov. 2019 HOBART


Installation and Operation Manual
Ecomax / Ecomax+ EN

7.8 Executing weekly cleaning 19


7.9 Top up salt reservoir 19

8 Settings 19
8.1 Overview of operator menu 19
8.2 Opening the operator menu 19
8.3 Detergent/dosage amount 20
8.4 Rinse aid/dosage amount 20
8.5 Setting the water hardness (optional) 21
8.6 Wash cycles 21
8.7 Hose filling detergent 22
8.8 Hose filling rinse aid 23
8.9 External water treatment 23
8.10 Temperatures 26
8.11 Displaying the temperatures 27

9 Display of faults and information 28


9.1 Error 28
9.2 Information 29

10 Troubleshooting guide 29
10.1 Poor wash result 29
10.2 Other faults 30

11 Maintenance 30

12 Disposal 31

13 Product disclaimer 31

14 Conformity 32

HOBART 0000000286-001-EN / 28. Nov. 2019 3


EN Ecomax / Ecomax+ Installation and Operation Manual

Notes on the documentation

1 Notes on the documentation

1.1 Application
This document contains the most important information for the installation and commissioning of the machine by
qualified personnel, as well as the information required for day-to-day operation by the operator.
▶ Keep the operation manual and all referenced documents in a safe and accessible place.
▶ Store the operation manual in a suitable container protected from humidity and dirt deposits.
▶ If you sell the machine, pass on the installation and operation manual.

1.2 Layout of the documentation


Referenced documents are all instructions that describe the installation, operation, maintenance and repair of the
device, as well as additional instructions for all accessories used.
For the operator:
‒ Operating instructions
For the specialised tradesman:
‒ Installation instructions
‒ Circuit diagram
‒ Spare Parts Catalogue

1.3 Symbols used


Symbol Meaning
Warning of hazardous electrical voltage

Beware of explosion
EX

Warning of risk of crushing

Beware of hazardous substances

Beware of hand injuries

Beware of slipping

Beware of hazard area

Useful additional information and tips

4 0000000286-001-EN / 28. Nov. 2019 HOBART


Installation and Operation Manual
Ecomax / Ecomax+ EN
Safety instructions and regulations

2 Safety instructions and regulations

2.1 Hazard levels


The hazard level is part of the safety instructions and is denoted by the signal word.
Potential consequences are differentiated by the choice of signal word.

imminent danger:
DANGER results in serious physical injury or death

potentially hazardous situation:


WARNING can cause serious physical injury or death

potentially hazardous situation:


CAUTION can cause minor physical injury

potentially harmful situation:


NOTICE can cause damage to the product or other objects

2.2 Layout of safety instructions


These warning notices are depicted with warning symbols and signal words in the corresponding safety colours.

CAUTION!
Nature and source of the hazard
Explanation on the nature and source of the hazard
▶ Measures for averting the hazard
▶ Additional measures for averting the hazard, where applicable

2.3 Basic safety instructions


2.3.1 Product safety
The machine conforms to state-of-the-art technology and the recognised safety regulations. Nonetheless, hazards
may occur.
▶ Operate the machine only in compliance with the operation manual.
▶ During machine handling, observe the safety instructions and warning notices that precede each action.
All modifications and alterations to the product are reserved for persons authorised by HOBART.

2.3.2 Personnel qualification


▶ Observe the regulations on occupational health and safety.
▶ Carefully read through the Operation Manual before use.

Activity User group Qualification/training


Installation Qualified personnel Hobart Service or an electrically qualified person trained by
Hobart or a competent person acc. to the German technical
regulations for occupational safety (TRBS 1203) trained by
Hobart

HOBART 0000000286-001-EN / 28. Nov. 2019 5


EN Ecomax / Ecomax+ Installation and Operation Manual

Safety instructions and regulations

Activity User group Qualification/training


Trainees Only under professional supervision and examination
Commissioning Qualified personnel Hobart Service or an electrically qualified person trained by
Hobart or a competent person acc. to the German technical
regulations for occupational safety (TRBS 1203) trained by
Hobart
Trainees Only under professional supervision and examination
Work on electrical sys- Qualified personnel Hobart Service or an electrically qualified person trained by
tem Hobart or a competent person acc. to the German technical
regulations for occupational safety (TRBS 1203) trained by
Hobart
Work on refrigeration Qualified personnel Category 1 expert certified in accordance with:
systems - Ordinance (EU) No. 517/2014 Article 10
- Implementing regulation (EU) 2015/2067
- German Chemicals Climate Protection Ordinance §5
Operation Operating personnel Only under supervision and after instruction by the operator on
and persons over the the basis of the operating instructions, instructions on dangers
age of 14
Disabled persons The suitability must be assessed by the operator on an individ-
ual basis
Persons up to the age Persons up to the age of 13 are not suited for machine opera-
of 13 tion
Maintenance, repair Qualified personnel Hobart Service or an electrically qualified person trained by
Hobart or a competent person acc. to the German technical
regulations for occupational safety (TRBS 1203) trained by
Hobart
Trainees Only under professional supervision and examination

2.3.3 Product-specific hazards


Avoid body parts being crushed or knocked:
▶ Observe the instructions on the packaging for storage, lifting or transporting.
Avoid risk of explosion:
▶ Do not install machine in a potentially-explosive location.
Avoid electric shock, fire risk:
▶ Do not allow water to flow under live components.
‒ Make sure the machine is correctly stored (see frost damage section 2.4).
‒ Make sure that the machine does not overflow when being filled.
▶ Do not damage the connection cable while unpacking.
▶ Have the machine connected to the power supply by qualified personnel.
▶ Have all modifications to the machine carried out by qualified personnel.
▶ Have additional feed tanks mounted by qualified personnel.
▶ Do not operate the machine unsupervised.
Avoid fire risk:
▶ Do not allow water to flow under live components.
‒ Make sure the machine is correctly stored (see frost damage section 2.4).
‒ Make sure that the machine does not overflow when being filled.

6 0000000286-001-EN / 28. Nov. 2019 HOBART


Installation and Operation Manual
Ecomax / Ecomax+ EN
Product description

▶ Have the machine connected to the power supply by qualified personnel.


▶ Have all modifications to the machine carried out by qualified personnel.
Avoid chemical burns, sensitisation of the skin, poisoning:
▶ Wear protective equipment (gloves, safety goggles, protective clothing) when handling chemicals.
▶ Use only suitable chemicals. Observe the manufacturer`s data.
▶ Have chemical sensor system set by authorised trained service technicians.
▶ Do not open the machine during operation, wait for the program to finish.
▶ Disconnect the machine from the mains prior to cleaning.
▶ For cleaning, wear protective equipment (gloves, safety goggles, protective clothing) when touching parts conta-
minated by detergent.
Avoid burns, scalds (to the hands):
▶ Do not open the machine during operation or the evaporation phase, wait for the programme to finish.
Otherwise, hot water could spray out.
▶ Disconnect the machine from the mains prior to cleaning.
Avoid slipping:
Moisture can build up on the machine floor.
▶ Provide a floor covering that is guaranteed to be non-slip in case of moisture.
Residues on the washware, hygiene regulations not maintained.
▶ Hygiene regulations must be maintained and/or demonstrated in accordance with the national provisions.

2.3.4 Additional hazards


Potential hazards caused by operating resources to be used can be found in the enclosed safety datasheets. Work-
places must be signed accordingly.

2.4 Property damage


Avoid frost damage:
Temperatures below 0°C lead to functional damage.
▶ Before storing below 0°C, empty residual water in hoses, tank and boiler.
▶ Prior to restart, store the machine at room temperature (min. 15°C) for 24h.
Avoid water damage:
▶ Do not operate the machine without supervision.
▶ Close on-site shut-off valves at the end of operation.

3 Product description

3.1 Intended purpose


The machine is an item of technical equipment intended solely for commercial dishwashing.
The machine is designed solely for cleaning crockery (porcelain, glass, ceramic, temperature-resistant plastics or
stainless steel or similar) from the food industry.
Not for washing:
‒ Containers that do not come into contact with foodstuffs, such as ashtrays, candlesticks, electric appliances etc.
‒ Animals or textiles
‒ Foodstuffs intended for further consumption

HOBART 0000000286-001-EN / 28. Nov. 2019 7


EN Ecomax / Ecomax+ Installation and Operation Manual

Controls

3.2 Designation
The rating plate is located at the side of the machine and contains the following information: model, serial number,
date of manufacture, country of manufacture, voltage, connection rating, design-state number and CE mark.

3.3 Technical specifications


Dimensions (H x W x D) 1480 x 635 x 742 mm
Water consumption per basket 2.3 l
Flow pressure 2-6 bar (models with booster pump: 0.5 – 10 bar, min. 0.8 bar with
integrated softener)
Cold or hot water connection max. 60°C
Voltage see rating plate
Total connected load
Fuse protection
Tank capacity (l) 23
Rack height 440
Noise emission dB (A) (workplace-related 67
emission value)
Weight (kg) 100

4 Controls

3 2 5 4 1

① ON/Escape key Pressing this key switches the machine on.


In case of operating error or faults, the machine can be switched off immedi-
ately without prior pump out by pressing this key.
After switch off, however, the machine is not voltage free.
② Programme selection key Press the key to choose between 3 different programmes.
③ Programme start key With the standard setting, the wash programme is started by closing the
hood. Alternatively by pressing the key.
④ OFF/Drain key Pressing and holding (3 seconds) this key activates the automatic self-clean-
ing cycle and then switches off the machine automatically. On machines with
drain pump, the tank is emptied.
After switch off, however, the machine is not voltage free.
⑤ Temperature display, rinsing Standard setting shows the maximum temperature achieved during the last
wash programme.
⑥ Temperature display, washing

8 0000000286-001-EN / 28. Nov. 2019 HOBART


Installation and Operation Manual
Ecomax / Ecomax+ EN
Installation

5 Installation

5.1 Personnel qualification


Installation must only be carried out by qualified personnel (see section 2.3.2).

5.2 Special safety instructions

WARNING!
Risk of electric shock, fire hazard
Water (frost damage, machine overflow) flowing over live components can cause injury from elec-
tric shock or fire.
▶ Do not allow water to flow under live components.
▶ Make sure the machine is correctly stored (see frost damage section 2.4).
▶ Make sure that the machine does not overflow when being filled.

CAUTION!
Risk of being crushed or knocked
When being lifted or transported, the machine can overturn or fall and cause injury.
▶ Observe the instructions on the packaging for storage, lifting or transporting.

WARNING!
Risk of explosion
Installing the machine in a potentially explosive location can cause explosion and serious injury
EX from ejected parts.
▶ Do not install machine in a potentially-explosive location.

NOTICE!
Frost damage
Temperatures below 0°C during transport/storage cause function impairments.
▶ Prior to installation, store the machine at room temperature (min. 15°C) for 24h.

HOBART 0000000286-001-EN / 28. Nov. 2019 9


EN Ecomax / Ecomax+ Installation and Operation Manual

Installation

5.3 Transporting to the installation location


▶ If possible, transport the machine in its packaging and on the
pallet.

▶ Use suitable transport means (elevating truck, crane etc.).


▶ If using a forklift, shim the machine with wooden trusses.

5.4 Removing the packaging

CAUTION!
Risk of electric shock, fire hazard
When the machine is unpacked, the connection cable can become damaged and cause injury from
electric shock or fire.
▶ Do not damage the connection cable while unpacking the machine.
▶ Take cable measurement DGUV V3.

▶ Remove packaging materials and accessories from the machine.


▶ Inspect the machine for possible transport damage.

5.5 Installing the machine

WARNING!
Risk of electric shock, fire hazard
Water ingress can cause short circuit and mortal danger from electric shock and fire.
▶ As a protection against penetrating water, the rear side of the machine must be sealed.
▶ If this cannot be guaranteed, a back covering must be also ordered.

▶ Seal the machine against the wall, or attach the optionally-available back covering.
▶ Cut-outs in the rear machine frame for supply lines etc., must also be sealed (sealing kit 01-539610-001 option-
ally available).
▶ Align machine by turning the adjusting feet by using a spirit level.
Installing the machine in the corner:
▶ Maintain a side wall clearance of 107 mm.
Installing the machine in a room:
▶ Attach the optionally-available back covering.
Converting to corner operation:
▶ Modify the basket guide rails in accordance with the pass-through direction (see arrows).

10 0000000286-001-EN / 28. Nov. 2019 HOBART


Installation and Operation Manual
Ecomax / Ecomax+ EN
Installation

Remove the front side guides by loosening the screws.

▶ Re-mount the side guide in accordance with the pass-through direc-


tion.

5.6 Connecting to the power supply

WARNING!
Risk of electric shock
Failure to connect properly to the power supply can cause mortal danger from electric shock.
▶ Have the machine connected to the power supply only by qualified personnel.

NOTE: To guarantee the electrical safety of the machine, it must be connected to a protective earthing
equipment conductor installed as specified. In addition, the machine must be connected on site to the
equipotential bonding connection. The connecting screw ( ) provided for this purpose is located next to
the cable inlet.
These fundamental safety requirements and the professional design of the on-site installation must be
verified by a qualified electrician.
Hobart does not accept any liability for damage caused by improper installation! Any applicable local
installation instructions must be observed!
The mains cable must be connected via a cut-out device (main switch or accessible plug device).
Modification to an alternative power supply is possible as per the variants on the circuit diagram. Connection dia-
grams are located adjacent to the connection terminals.

5.7 Connecting the water

NOTICE!
Property damage
The use of old hose sets for connection to the water supply facility can cause water damage.
▶ The included connection hose must be used for connection to the water supply facility.
▶ Old hose sets cannot be reused.

NOTE: The machine must be operated with potable water.


▶ If possible, connect to warm water (max. 60 °C).
Water hardness:
‒ Machines without softener: max. 1 °d = 0.18 mmol/l.
‒ Machines with softener: max. 30 °d = 5.3 mmol/l.

HOBART 0000000286-001-EN / 28. Nov. 2019 11


EN Ecomax / Ecomax+ Installation and Operation Manual

Installation

Flow pressure:
‒ Machines without softener: 2 - 6 bar (for models with booster pump 0.5 – 10 bar)
‒ Machines with softener: 0.8 – 10 bar
‒ If the flow pressure is higher: provide pressure reducing valve.

▶ Connect the union nut "A" (3/4" thread) of the water supply hose to
the site shut off valve.
A

▶ Do not kink or cut the water supply hose.


▶ Any required extension must be executed using a suitable pressure hose, e.g. 324088-1.

5.8 Connecting the drain


Machines with drain pump
▶ Do not kink or lay the drain hose loose on the ground.

max. 750 mm

The connection between machine and site drain must not exceed the max. height of 0.75 m.

Machines without drain pump


▶ Ensure gravity drain.
▶ Do not kink drain hose.
max. 100 mm

For these machine types, a floor drain is mandatory as the drain hose exits the machine at approx. 100 mm above
floor level. Otherwise, residual water may remain in the tank and hose.

5.9 Connecting the dispenser


Some model variants are factory-equipped with integrated dispensers. When converting or installing different dis-
pensers, make the connection as follows.

12 0000000286-001-EN / 28. Nov. 2019 HOBART


Installation and Operation Manual
Ecomax / Ecomax+ EN
Installation

▶ Drain tank.
▶ Turn off on site main switch or remove the plug.
▶ Remove frontal covering.

Connecting the liquid dispenser:


▶ A metering nipple is available on top of the boiler for dispensing rinse aid.
▶ For detergent dosing, connect the hose (PVC / Ø 6 mm outside × Ø 4
mm inside) between the pressure side of the dispenser and the
metering nipple (A) on the wash tank, secure with hose clamp.

▶ Install dispenser or mount externally.


To connect a powder or solid detergent dispenser:
▶ Remove the side cover (depending on left or right connection).
▶ Break out sheet perforation on the sheet outer jacket.

▶ Drill out the inner tank wall behind according to the required connec-
tion diameter.

▶ Screw the dosing connection tightly to the tank wall.


▶ Connect the plug of the cable harness to the dispenser (max. 100 VA).
Installing the connectivity probe:
▶ Conductivity probe should be installed at the flat part of tank bottom.
▶ Drill out the tank according to the probe diameter.

▶ Replace cover(s).

HOBART 0000000286-001-EN / 28. Nov. 2019 13


EN Ecomax / Ecomax+ Installation and Operation Manual

Commissioning

▶ Turn on site main switch or insert the plug.


▶ Set the dispenser and the sensor system.

6 Commissioning

6.1 Personnel qualification


Commissioning must only be carried out by qualified personnel (see section 2.3.2).

6.2 Special safety instructions


NOTE: Before commissioning the machine, the relevant electrical safety checks must be performed
according to the locally applicable regulations!

6.3 Setting the water hardness (optional)


Machines with integrated softener have a water hardness setting.
NOTE: The softener must be set to the existing water hardness (ask at the local water works).
▶ Set hardness range according to section 8.5.

6.4 Filling the salt reservoir (optional)

NOTICE!
Property damage
Accidentally filling the salt reservoir with detergent will damage the water softener.
▶ Do not fill the salt reservoir with detergent.

Unlike the regular salt fill, additional water has to be added during the commissioning procedure.

▶ Open the door.


▶ Unscrew the salt reservoir lid and add approx. 1 kg of
granular (2-8 mm) regenerating salt (do not use salt tab-
lets).

▶ Fill up the reservoir with potable water (only at commissioning).


▶ Make sure the lid seal is free of dirt and salt.
▶ Screw lid back on and tighten.

14 0000000286-001-EN / 28. Nov. 2019 HOBART


Installation and Operation Manual
Ecomax / Ecomax+ EN
Commissioning

NOTICE!
Property damage
Salt residues on the tank floor cause corrosion damage.
▶ Remove salt residues by hand.
▶ On completion of the commissioning procedure, start a wash cycle to remove all traces of salt
if necessary.

▶ If salt deficiency occurs during operation, the top display


shows "SA", the bottom display shows "Lt".

▶ To pump out water in the tank, see section 7.6.


▶ Top up salt (see above). It then takes a few minutes until the display disappears.

6.5 Filling chemical hoses


NOTE: Only for installed dosing units

We recommend the use of HOBART Hyline detergent and rinse aid.

NOTE: Mixing chemicals in the hose when exchanging chemicals can lead to crystallisation and damage to
the hoses and dosing units. This is prevented by intermediary rinsing with water (see section 8.7). Failure
to comply with this information will invalidate the guarantee and product liability.

CAUTION!
Chemical burns, sensitisation of the skin, poisoning
The use of unsuitable chemicals can cause injury.
▶ Use only commercial detergent and rinse aid.
▶ Observe the manufacturer's application and safety instructions.

WARNING!
Chemical burns, sensitisation of the skin, poisoning
Incorrect handling of detergent or rinse can lead to serious injuries.
▶ Wear protective equipment (gloves, safety goggles, protective clothing) when handling chemi-
cals.

6.5.1 Provisioning external chemical canisters


Preparing the detergent:
Suction height of dosing pump: max. 1.5 m.

HOBART 0000000286-001-EN / 28. Nov. 2019 15


EN Ecomax / Ecomax+ Installation and Operation Manual

Operation

▶ Place suction hose without colour marking at the suction valve at the bottom of
the external reservoir.

Preparing the rinse aid:


Suction height of dosing pump: max. 1.5 m.
▶ Place suction hose with blue marking at the suction valve at the bottom of the external reservoir.

7 Operation

7.1 Personnel qualification


The machine must be operated by instructed personnel (see section 2.3.2).

7.2 Special safety instructions

CAUTION!
Chemical burns, sensitisation of the skin, poisoning, burning
If the Hood is opened during operation, vapour can escape and/or wash water can spurt out and
cause injury.
▶ Do not open the Hood during operation, wait for the program to finish.

WARNING!
Danger of slipping
Moisture can build up on the machine floor and cause slipping.
▶ Provide a floor covering that is guaranteed to be non-slip in case of moisture.

7.3 Preparations for washing


7.3.1 Preparing the machine
▶ Check correct position of wash/rinse arms, strainers and if fitted stand pipe.
▶ Open site shut-off valve.
▶ Turn on main switch or insert the plug.
▶ Check level of detergent and rinse aid container.

16 0000000286-001-EN / 28. Nov. 2019 HOBART


Installation and Operation Manual
Ecomax / Ecomax+ EN
Operation

(See section 6.5).

▶ Close Hood.
▶ Press the ON/Escape key .

During the filling and heating processes, the key LED flashes. This process can take several minutes.
As soon as the LED is permanently lit, the machine is ready for operation and displays the current wash tem-
perature in the lower display.

7.3.2 Preparing the washware


▶ Remove any food residue.
▶ Place wash ware face down in the rack.

▶ Rinse off wash ware.

7.4 Displaying and selecting the program


Press the programme selection key to show the current programme in the display. Press the key continuously to
choose between 3 programmes (P1 = short, P2 = standard, P3 intensive). This is not possible if an error is dis-
played and while the programme is running.

HOBART 0000000286-001-EN / 28. Nov. 2019 17


EN Ecomax / Ecomax+ Installation and Operation Manual

Operation

7.5 Washing
▶ Slide rack into the machine and close the hood.

While the program is running, the program key LED flashes.


As soon as the LED lights up permanently, the rinsing process is complete.
▶ Open the hood and remove the rack.
▶ Allow the wash ware enough time to dry.
▶ Until the next wash process, place the hood in the stand-by position
(engaged position just before closing), to prevent cooling down.

7.6 Switch off machine


▶ Versions with stand pipe: Pull.

▶ Close Hood.
▶ Press and hold the Drain key (min. 3 seconds).

During pump out, the Drain key LED flashes.

During pump out, the machine interior is cleaned automatically. On machines with drain pump, the
tank is emptied. At the end of the program, the machine switches off automatically. Then remove
any coarse food residues.

When the machine has switched off:


▶ Turn off main switch or remove the plug.
▶ Close on-site shut-off valve.

18 0000000286-001-EN / 28. Nov. 2019 HOBART


Installation and Operation Manual
Ecomax / Ecomax+ EN
Settings

7.7 Executing daily cleaning

NOTICE!
Property damage
The use of unsuitable agents can cause corrosion or damage to the surfaces.
▶ Do not use any chlorine-containing, acidic or metal-containing additives to clean the machine.
▶ Do not use metal sponges.

▶ Open hood.
▶ Remove sieves and clean. Make sure that food debris does not enter pump intake!
▶ Clean machine areas that cannot be reached by the water circulation of the self cleaner (hood labyrinth, rear
side riser pipe, etc.).
▶ Replace strainer.
▶ Leave the hood open for ventilation.

7.8 Executing weekly cleaning


▶ Release the screw fastener on the wash and rinse arms, remove the wash and rinse arms and clean.
▶ Replace the wash and rinse arms.

7.9 Top up salt reservoir


The salt deficiency display flashes during operation.
▶ Top up salt reservoir, see 6.4.
The display takes a few minutes to extinguish.

8 Settings

8.1 Overview of operator menu


Submenu Function
Detergent/dosage amount Setting
Rinse aid/dosage amount Setting
Water hardness Setting
Wash cycles Display
Hose filling detergent For commissioning and replacement of the canister.
Hose filling rinse aid For commissioning and replacement of the canister.
External water treatment Resetting
Remaining capacity
Activate/deactivate
Output capacity
Temperatures Standard / Thermolabel 71°
Display

8.2 Opening the operator menu


NOTE: Possible only when the machine is switched off.

HOBART 0000000286-001-EN / 28. Nov. 2019 19


EN Ecomax / Ecomax+ Installation and Operation Manual

Settings

▶ Open Hood.
▶ Press the Short programme key (1) and the Standard
programme key (2) at the same time.

The menu opens, key LEDs illuminate.


The first submenu item "1" appears as soon as the door is closed.

If the menu is opened again, the display switches off and the entered settings are saved.
The setting sequence described below can therefore be interrupted at any time.
▶ Press the Short programme key (1) to scroll through the menus.

8.3 Detergent/dosage amount


Only relevant for integrated detergent/dosing units.
▶ Top display shows "01"
▶ The bottom display shows the current dosage value,
default setting: 2.5 g/l

▶ To adjust the detergent/dosing quantity, increase using


the Standard programme key (2) or reduce using the
Drain key. The selected value (0-9.5 g/l) will be saved
automatically.

▶ Make settings according to the recommendations of the detergent supplier.


▶ Open the hood to escape and exit the menu.

8.4 Rinse aid/dosage amount


▶ Open menu (see section 8.2).
▶ Press the Short programme key (1) until the top display shows "02".
▶ The bottom display shows the current dosage value,
default setting: 0.3 g/l.

20 0000000286-001-EN / 28. Nov. 2019 HOBART


Installation and Operation Manual
Ecomax / Ecomax+ EN
Settings

▶ To adjust the rinse aid/dosage quantity, increase using


the Standard programme key (2) or reduce using the
Drain key. The selected value (0-2 g/l) is automatically
saved.

▶ Making settings according to the instructions of the rinse aid supplier.


▶ Open the hood to escape and exit the menu.

8.5 Setting the water hardness (optional)


Only relevant with integrated softener.
NOTE: The softener must be set to the existing water hardness (ask at the local water works).
▶ Open menu (see section 8.2).
▶ Press the Short programme key (1) until the top display
shows "03".

▶ The bottom display indicates the set degree of hardness in °d.


▶ To adjust the degree of hardness, increase using the
Standard programme key (2) or reduce using the Drain
key. The selected value (1-30) is automatically saved.

▶ Open the hood to escape and exit the menu.

8.6 Wash cycles


▶ Open menu (see section 8.2).
▶ Press the Short programme key (1) until the top display
shows "04".

Due to the bottom display being limited to 2 places, the value (max. 6 places) is shown as follows:
e.g. for wash programmes 003456.

HOBART 0000000286-001-EN / 28. Nov. 2019 21


EN Ecomax / Ecomax+ Installation and Operation Manual

Settings

▶ Pressing the Standard programme key (2) displays the


first two places.

▶ The next two places are shown when the Standard pro-
gramme key (2) is pressed.

▶ The last two places are shown by pressing the Standard


programme key (2).

▶ If the key is pressed again, the first display reappears, etc.


▶ Open the hood to escape and exit the menu.

8.7 Hose filling detergent


▶ Open menu (see section 8.2).
▶ Press the Short programme key (1) until the top display
shows "05".

Bottom display shows "0".


▶ Using the Standard programme key (2) to set the bottom
display to "1".

▶ Press the Drain key.

Hose filling starts for approx. 60 seconds.


Item in bottom display flashes.
▶ Filling is completed when the flashing stops.
▶ Open the hood to escape and exit the menu.

22 0000000286-001-EN / 28. Nov. 2019 HOBART


Installation and Operation Manual
Ecomax / Ecomax+ EN
Settings

There is no need to wait until the end once the filling process has been activated. The filling of the rinse aid hose
can also start in parallel.

8.8 Hose filling rinse aid


▶ Open the Settings menu (see section 8.2).
▶ Press the Short programme key (1) until the top display
shows "06".

Bottom display shows "0".


▶ Using the Standard programme key (2) to set the bottom
display to "1".

▶ Press the Drain key.

Hose filling starts for approx. 120 seconds.


Item in bottom display flashes.
▶ Filling is completed when the flashing stops.
▶ Open the hood to escape and exit the menu.

8.9 External water treatment


Relevant only when activated (see section 8.9.3)
This can be used to monitor the capacity of an external water treatment or a pre-filter on the basis of the calculated
water flow.

8.9.1 Resetting
Reset the remaining capacity to the output capacity value.
▶ Open menu (see section 8.2).
▶ Press the Short programme key (1) until the top display
shows "07".

Bottom display shows "0".

HOBART 0000000286-001-EN / 28. Nov. 2019 23


EN Ecomax / Ecomax+ Installation and Operation Manual

Settings

▶ Set the bottom display to "1" by pressing the Standard


programme key (2).

The ON/Escape key LED flashes.


▶ The total capacity is reset again by pressing the ON/
Escape key for 3 sec.

The ON/Escape key LED illuminates for 3 sec.


▶ Open the hood to escape and exit the menu.

8.9.2 Remaining capacity


The remaining capacity counts backwards from the set output capacity value and can be shown as follows:
▶ Open menu (see section 8.2).
▶ Press the Short programme key (1) until the top display
shows "08".

Due to the bottom display being limited to 2 places, the value (max. 6 places) is shown as follows:
▶ Pressing the Standard programme key (2) displays the
first two places.

▶ The next two places are shown when the Standard pro-
gramme key (2) is pressed.

▶ The last two places are shown by pressing the Standard


programme key (2).

▶ If the key is pressed again, the first display reappears, etc.


▶ Open the hood to escape and exit the menu.

24 0000000286-001-EN / 28. Nov. 2019 HOBART


Installation and Operation Manual
Ecomax / Ecomax+ EN
Settings

If necessary, the value can also be set as shown in section 8.9.4.

8.9.3 Activate/deactivate
This must be deactivated to use the capacity monitoring.
▶ Open menu (see section 8.2).
▶ Press the Short programme key (1) until the top display
shows "09".

Bottom display shows the current setting:


"0" = deactivated
"1" = demineralisation cartridge (assumption: 3 l/min)
"2" = reverse osmosis system (assumption = 1.5 l/min)
▶ Set using the Standard programme key (2) or Drain key.

The ON/Escape key LED flashes.


▶ The value is saved by pressing the ON/Escape key for 3
sec.

The ON/Escape key LED illuminates for 3 sec.


▶ Open the hood to escape and exit the menu.

8.9.4 Output capacity


Value is preset to 14000 l.
To display or change:
▶ Open menu (see section 8.2).
▶ Press the Short programme key (1) until the top display
shows "10".

Due to the bottom display being limited to 2 places, the value (max. 6 places) is shown as follows:

HOBART 0000000286-001-EN / 28. Nov. 2019 25


EN Ecomax / Ecomax+ Installation and Operation Manual

Settings

▶ The first two places are shown in the lower display by


pressing the ON/Escape key.

▶ To adjust the first two places, use the Standard pro-


gramme key (2) to increase or the Drain key to reduce.

The ON/Escape key LED flashes


▶ The next two places are shown when the Short pro-
gramme key (1) is pressed.

▶ Set the first two places in the same way as required.


▶ The last two places are shown by pressing the Short pro-
gramme key (1).

▶ Set the first places in the same way as required.


▶ Press the ON/Escape key for 3 sec. to exit the menu list
or to save a changed value.

If the value is changed, the ON/Escape key LED illuminates for 3 sec.
▶ The first display is shown again when the Short programme key (1) is re-pressed.
▶ Open the hood to escape and exit the menu.

8.10 Temperatures
Here, it is possible to change from standard temperatures complying to DIN 10534 to elevated temperatures com-
plying to NSF (Thermolabel 71° C). As a result, the program run times are extended.
▶ Open menu (see section 8.2).
▶ Press the Short programme key (1) until the top display
shows "11".

26 0000000286-001-EN / 28. Nov. 2019 HOBART


Installation and Operation Manual
Ecomax / Ecomax+ EN
Settings

Bottom display shows the current setting:


"0" = standard temperatures
"1" = increased temperatures
▶ Set using the Standard programme key (2) or Drain key.

The ON/Escape key LED flashes.


▶ The value is saved by pressing the ON/Escape key for 3
sec.

The ON/Escape key LED illuminates for 3 sec.


▶ Open the hood to escape and exit the menu.

8.11 Displaying the temperatures


▶ Open menu (see section 8.2).
▶ Press the Short programme key (1) until the top display
shows "12".

Bottom display shows the current setting:


"0" = no display of temperatures.
"1" = display shows the maximum temperature reached during the last wash programme.
"2" = display shows the current boiler and wash tank temperatures.
▶ Set using the Standard programme key (2) or Drain key.

▶ Open the hood to escape and exit the menu.

HOBART 0000000286-001-EN / 28. Nov. 2019 27


EN Ecomax / Ecomax+ Installation and Operation Manual

Display of faults and information

9 Display of faults and information

9.1 Error
▶ "Er" appears in the top display.

▶ The error code is shown in the bottom display (see table).

Error code Reason Remedy


01 Temperature boiler sensor exceeded. Contact your HOBART Service Partner.
02 Temperature boiler sensor undercut. Contact your HOBART Service Partner.
03 Hot water tank thermostop in wash programme. Contact your HOBART Service Partner.
05 Temperature tank sensor exceeded. Contact your HOBART Service Partner.
06 Temperature tank sensor undercut. Contact your HOBART Service Partner.
07 Upper limit of pressure sensor for boiler excee- Contact your HOBART Service Partner.
ded.
08 Total value pressure sensor boiler undercut. Contact your HOBART Service Partner.
09 Total value of pressure sensor for tank excee- Contact your HOBART Service Partner.
ded.
10 Total value pressure sensor tank undercut. Contact your HOBART Service Partner.
12 Water level regulation in wash tank failed. Contact your HOBART Service Partner.
13 Filling programme monitor pressure sensor tank. Pump out machine.
14 Wash tank draining in pump out programme for Clean the drain hose if necessary and pump-out
tank pressure sensor. the machine again.
17 Filling monitoring by impeller sensor. Check water supply.
18 Filling monitoring by measuring the water level Check water supply.
in the boiler.
28 Fill level of wash tank too low at programme The machine refills automatically and starts the
start. programme. If the error is permanently dis-
played, contact your HOBART Service Partner.
29 Capacity of external water treatment unit deple- Replace part or full desalination cartridge.
ted.
31 Filling monitoring Check water supply.
Contact your HOBART Service Partner.

28 0000000286-001-EN / 28. Nov. 2019 HOBART


Installation and Operation Manual
Ecomax / Ecomax+ EN
Troubleshooting guide

9.2 Information
▶ The following instructions are shown with a letter combi-
nation in the display.

Display Reason Remedy


SA Lt Regenerating salt depleted. Refill regenerating salt (see section 6.4).
do or Filling, washing or pump-out programme inter- Close the hood
rupted

10 Troubleshooting guide

10.1 Poor wash result


Fault type Possible cause Remedy
Washware not clean. Wash arm stiff (must rotate easily by hand). Remove wash arms and clean them thor-
oughly.
Also check water outlet from machine to
wash arm is clear.
Wash arm nozzles are clogged (visual Remove wash arm, remove cleaning caps
check). and rinse wash arm thoroughly until all soil-
ing is removed.
Replace cleaning caps.
Rinse nozzles clogged (usually by lime Remove rinse arms and descale them in
deposit). separate container.
Check site softening system for function.
Detergent concentration is too low or too Check detergent concentration setting.
high.
Coarse strainer clogged. Remove, empty and clean strainer.
Fine strainer clogged or obstructed by lime Remove fine strainer. If heavily soiled, soak
deposits. in a vinegar solution. Then clean it thor-
oughly with a brush until the pores are free.
The fine strainer should generally be
cleaned daily.
Wrong programme selected for heavily Select programme with longer wash cycle.
soiled washware.
Washware or glasses Rinse aid dosing too low. Increase dosage.
dry poorly. Washware still greasy. Detergent concentration too low: increase
dosage.
Check if detergent is appropriate. If not,
choose a stronger one.
Drain contaminated water and refill
machine. Improve the preliminary cleaning
of the washware.

HOBART 0000000286-001-EN / 28. Nov. 2019 29


EN Ecomax / Ecomax+ Installation and Operation Manual

Maintenance

Fault type Possible cause Remedy


Rack is not suitable for type of dishes (slop- Use appropriate racks to create a sloping
ing). position which allows water to drain away
from cavities.
Washware remains in the machine too long Remove washware as soon as cycle is
at the end of wash cycle. completed to enable it to dry.
Streaks and spots on Rinse aid concentration too high (stripe or Reduce dosage.
washware or glasses. bubble formation).
Hard water or high mineral content. Check water quality.
Every local water works holds data on the
composition of the water they supply and
will provide these on request.
Reference values: Ideal calcium value: 0 –
3°d (total hardness). Ideal mineral content
value: for glasses, max. conductivity 100
µS/cm, for dishes, still viable to max. 400
µS/cm.
Rack is not suitable for type of dishes (slop- Use appropriate racks to create a sloping
ing). position which allows water to drain away
from cavities.
Inadequate rinse aid dosing causes stains. Increase rinse aid dosing.
Machines with integrated softener: use of Do not use salt tablets.
wrong salt (e.g. tablets).

10.2 Other faults


Fault type Potential causes Remedy
Glasses are totally or Surface of glasses is rough and porous, Use new glasses, this is not caused by a
partially cloudy. this is called glass corrosion. malfunction on the machine.
Glass/dish breakage. Use of unsuitable dish or glass racks. Use suitable racks.

11 Maintenance

▶ In order to maintain the warranty, as well as a permanently safe, efficient,


and trouble-free operation of the machine(s), the required maintenance
must be carried out by authorized service technicians. We therefore rec-
ommend the conclusion of an inspection and maintenance contract,
which guarantees qualified support by specially trained service techni-
cians according to a time schedule based on the operating conditions.

Genuine spare parts must be used for repairs and wearing part replacements. Wearing parts include dosing
hoses, rinse arm bearings, etc. In Germany, your HOBART machines are governed by the Ordinance on Indus-

30 0000000286-001-EN / 28. Nov. 2019 HOBART


Installation and Operation Manual
Ecomax / Ecomax+ EN
Disposal

trial Health and Safety and must be inspected by a qualified electrician in accordance with the intervals specified
by the Institute for Work and Health of the German Social Accident Insurance [DGUV V3 (BGV A3)].

12 Disposal

▶ The machine operator is responsible for disposing of the machine and its
operating materials correctly and in accordance with environmental regu-
lations. Observe the national and local legal provisions and regulations.

13 Product disclaimer

Product disclaimer
Installations and repairs carried out by non-authorized technicians or using non-genuine spare parts, and any tech-
nical alterations to the machine not approved by the manufacturer will invalidate the manufacturer's warranty and
product liability.
HOBART reserves the right to make changes or improvements to its products without prior notice.
© HOBART GmbH, Offenburg 2019

HOBART 0000000286-001-EN / 28. Nov. 2019 31


EN Ecomax / Ecomax+ Installation and Operation Manual

Conformity

14 Conformity

Original

EG-Konformitätserklärung
Declaration of Conformity / Déclaration de Conformité / Declaración de Conformidad / Dichiarazione di conformitá / Conformiteitsverklaring / Deklaracja zgodności / Декларация соответствия /
Uygunluk beyanı / Deklarcija o sukladnosti / Izjava o skladnosti / Declaração de Conformidade / Prohlášení o shodě

Hersteller / Dokumentationsbevollmächtigter: HOBART GMBH / Verena Wiedenhöfer


Manufacturer / authorized to compile the technical file: Robert-Bosch-Straße 17
Fabricant / autorisée à constituer le dossier technique: 77656 Offenburg / Germany
Fabricante / autorizado para unificar la información técnica:
Fabbricante / Responsabile della documentazione:
Fabrikant / Geautoriseerd om de technische documentatie samen te stellen:
Producent / autoryzowany przedstawiciel:
Изготовитель / ответственный за составление документации:
Üretici / Dokümantasyon yetkilisi:
Proizvođač / ovlašten za sastavljanje tehničkog spisa:
Proizvajalec / pooblaščeni za dokumentacijo:
Fabricante / Responsável pela documentação:
Výrobce / osoba zplnomocněná sestavením dokumentace:

Maschine: Geschirrspülmaschine
Machine: Dishwasher
Machine: Machine à laver la vaisselle
Máquina: Lavavajillas
Macchina: Lavastoviglie
Machine: Vaatwasmachine
Urządzenie: Zmywarka do naczyń
Машина: Посудомоечная машина
Makine: Giotin Typ Bulasik Makinasi
Stroj: Perilica posuđa
Stroj: Stroj za pomivanje posode
Máquina: Máquina lava-loiça
Stroj: Myčka na nádobí

Marke: ecomax by HOBART


Trade mark / Marque / Marca
comercial / Marchio / Merk /
Marka / Марка / Marka / Zaštitni
znak / Znamka / Marca / Značka

Type: EcomaxH604 - Serie Design State: AM-14-02 Serial No.: 86 57 3XXXX


EcomaxH614 - Serie
C-H604 - Serie
Max-H604 - Serie

Hiermit bestätigen wir, dass die genannte Maschine entsprechend den nachfolgend aufgeführten Normen gefertigt und geprüft worden ist.
Herewith our confirmation that the named machine has been manufactured and tested in accordance with the following standards.
Par la présente, nous déclarons que la machine citée ci-dessus a été fabriquée et testée en conformité aux normes.
Por la siguiente confirmamos que la máquina mencionada ha sido fabricada conforme a las siguientes normas.
Con la presente confermiamo che la macchina indicata è stata costruita in conformità alle norme di seguito riportate.
Hierbij bevestigen wij dat de genoemde machine is gefabriceerd en getest volgens de hiervolgende voorwaarden.
Niniejszym deklarujemy, że wymieniony produkt spełnia wymogi następujących norm.
Настоящим мы подтверждаем, что указанная машина изготовлена в соответствии с приведенными ниже нормами.
İşbu belge ile belirtilen makinenin aşağıda listelenen normlar doğrultusunda hazırlandığını beyan ederiz.
Ovime potvrđujemo da je gore navedeni stroj proizveden i testiran sukladno sljedećim standardima.
S tem izjavljamo, da je naveden stroj izdelan in preizkušen v skladu s spodaj navedenimi standardi.
Com a presente declaramos que a máquina supracitada foi construída e inspecionada segundo as normas referidas a seguir.
Tímto potvrzujeme, že uvedený stroj byl vyroben a zkontrolován podle následujících norem.

DIN SPEC 10534:2019-02


EN 55014-1:2006 + A1:2009 + A2:2011
EN 55014-2:2015
EN 60335-2-58:2005 + Corr. 2007 + A1:2008 + A11:2010 + A2:2015 + A12:2016
EN 61000-6-2:2005
EN 61000-6-3:2007 + A1:2011
EN ISO 12100:2010

Die Maschine stimmt mit den folgenden Richtlinien überein:


The product complies with the following directives:
La machine est conforme aux directives fixées:
La máquina armoniza con las siguientes Directivas:
La macchina è conforme alle direttive seguenti:
Het product voldoet aan de volgende richtlijnen:
Urządzenie spełnia wymogi następujących dyrektyw:
Машина соответствует требованиям следующих директив:
Makine, aşağıdaki yönetmelikler ile uyumludur:
Ovaj stroj je u skladu sa sljedećim direktivama:
Stroj ustreza zahtevam sledečih direktiv:
A máquina está em conformidade com as seguintes diretivas:
Stroj je v souladu s ustanoveními následujících směrnic:

2006/42/EC (Maschinenrichtlinie, Machinery-Directive)


2014/30/EU (EMV-Richtlinie, EMC-Directive)
2011/65/EU (RoHS Richtlinie, RoHS Directive)

Die Schutzziele der Niederspannungsrichtlinie 2014/35/EU wurden gemäß Anhang I Nr. 1.5.1 der Maschinenrichtlinie 2006/42/EC eingehalten.
Protective Goals of the Low Voltage Directive 2014/35/EU are in compliance with Appendix I No 1.5.1 of the Machinery Directive 2006/42/EC.
Les objectifs de protection de la directive sur les basses tensions 2014/35/EU ont été respectés conforme à l’annexe I Nr. 1.5.1 der de la directive relative aux machines 2006/42/EC.
Directiva de protecciones de baja tension 2014/35/EU estan en acuerdo con el apendice I No 1.5.1. de la directiva de maquinaria 2006/42/EC.
Gli obiettivi di protezione della direttiva per basse tensioni 2014/35/EU è stata rispettata secondo allegato I n. 1.5.1 della Direttiva per macchine 2006/42/EC.
De veiligheidsdoelstellingen van de laagspanningsrichtlijn 2014/35/EU zijn nageleefd in overeenstemming met nr. 1.5.1 van bijlage I van de machine richtlijn 2006/42/EC.
Produkt spełnia wymogi bezpieczeństwa dyrektywy niskonapięciowej 2014/35/EU, zgodnie z załącznikiem I nr. 1.5.1 dyrektywy maszynowej 2006/42/EC.
Цели, охраняемые Директивой по высоковольтному оборудованию 2014/35/EU, соблюдены в соответствии с приложением № 1.5.1 Директивы по машинному
оборудованию 2006/42/ЕС.
Alçak Gerilim Yönetmeliği 2014/35/EU'nin koruyucu hedeflerine, Makine Yönetmeliği 2006/42/EC, ek I no. 1.5.1'e göre uyulmuştur.
Sigurnosni ciljevi direktive o niskom naponu 2014/35/EU udovoljavaju dodatku i br. 1.5.1. Direktive o strojevima 2006/42/EC
Upoštevani so zaščitni cilji Direktive o nizki napetosti 2014/35/EU v skladu s prilogo I, št. 1.5.1 Direktive o strojih 2006/42/EC.
Os objetivos de proteção da Diretiva de Baixa Tensão 2014/35/EU foram cumpridos de acordo com o Apêndice I, n.º 1.5.1 da Diretiva de Máquinas 2006/42/EC.
Cíle ochrany dle nízkonapěťové směrnice 2014/95/ES byly splněny dle přílohy I č. 1.5.1 směrnice o strojních zařízeních 2006/42/ES.

Bestätigt durch:
Confirmed by: Offenburg, 04.09.2019 ppa.

Harald Disch
Direktor Produktentwicklung Europa
Director Warewash Engineering Europe

32 0000000286-001-EN / 28. Nov. 2019 HOBART


Installation and Operation Manual
Ecomax / Ecomax+ EN
Conformity

Original

EG-Konformitätserklärung
Declaration of Conformity / Déclaration de Conformité / Declaración de Conformidad / Dichiarazione di conformitá / Conformiteitsverklaring / Deklaracja zgodności / Декларация соответствия /
Uygunluk beyanı / Deklarcija o sukladnosti / Izjava o skladnosti / Declaração de Conformidade / Prohlášení o shodě

Hersteller / Dokumentationsbevollmächtigter: HOBART GMBH / Verena Wiedenhöfer


Manufacturer / authorized to compile the technical file: Robert-Bosch-Straße 17
Fabricant / autorisée à constituer le dossier technique: 77656 Offenburg / Germany
Fabricante / autorizado para unificar la información técnica:
Fabbricante / Responsabile della documentazione:
Fabrikant / Geautoriseerd om de technische documentatie samen te stellen:
Producent / autoryzowany przedstawiciel:
Изготовитель / ответственный за составление документации:
Üretici / Dokümantasyon yetkilisi:
Proizvođač / ovlašten za sastavljanje tehničkog spisa:
Proizvajalec / pooblaščeni za dokumentacijo:
Fabricante / Responsável pela documentação:
Výrobce / osoba zplnomocněná sestavením dokumentace:

Maschine: Geschirrspülmaschine
Machine: Dishwasher
Machine: Machine à laver la vaisselle
Máquina: Lavavajillas
Macchina: Lavastoviglie
Machine: Vaatwasmachine
Urządzenie: Zmywarka do naczyń
Машина: Посудомоечная машина
Makine: Giotin Typ Bulasik Makinasi
Stroj: Perilica posuđa
Stroj: Stroj za pomivanje posode
Máquina: Máquina lava-loiça
Stroj: Myčka na nádobí

Marke: ecomax by HOBART


Trade mark / Marque / Marca
comercial / Marchio / Merk /
Marka / Марка / Marka / Zaštitni
znak / Znamka / Marca / Značka

Type: Eco+H615 - Serie Design State: AMB-14-03 Serial No.: 86 57 7XXXX


HOBART615 - Serie

Hiermit bestätigen wir, dass die genannte Maschine entsprechend den nachfolgend aufgeführten Normen gefertigt und geprüft worden ist.
Herewith our confirmation that the named machine has been manufactured and tested in accordance with the following standards.
Par la présente, nous déclarons que la machine citée ci-dessus a été fabriquée et testée en conformité aux normes.
Por la siguiente confirmamos que la máquina mencionada ha sido fabricada conforme a las siguientes normas.
Con la presente confermiamo che la macchina indicata è stata costruita in conformità alle norme di seguito riportate.
Hierbij bevestigen wij dat de genoemde machine is gefabriceerd en getest volgens de hiervolgende voorwaarden.
Niniejszym deklarujemy, że wymieniony produkt spełnia wymogi następujących norm.
Настоящим мы подтверждаем, что указанная машина изготовлена в соответствии с приведенными ниже нормами.
İşbu belge ile belirtilen makinenin aşağıda listelenen normlar doğrultusunda hazırlandığını beyan ederiz.
Ovime potvrđujemo da je gore navedeni stroj proizveden i testiran sukladno sljedećim standardima.
S tem izjavljamo, da je naveden stroj izdelan in preizkušen v skladu s spodaj navedenimi standardi.
Com a presente declaramos que a máquina supracitada foi construída e inspecionada segundo as normas referidas a seguir.
Tímto potvrzujeme, že uvedený stroj byl vyroben a zkontrolován podle následujících norem.

DIN SPEC 10534:2019-02


EN 55014-1:2006 + A1:2009 + A2:2011
EN 55014-2:2015
EN 60335-2-58:2005 + Corr. 2007 + A1:2008 + A11:2010 + A2:2015 + A12:2016
EN 61000-6-2:2005
EN 61000-6-3:2007 + A1:2011
EN ISO 12100:2010

Die Maschine stimmt mit den folgenden Richtlinien überein:


The product complies with the following directives:
La machine est conforme aux directives fixées:
La máquina armoniza con las siguientes Directivas:
La macchina è conforme alle direttive seguenti:
Het product voldoet aan de volgende richtlijnen:
Urządzenie spełnia wymogi następujących dyrektyw:
Машина соответствует требованиям следующих директив:
Makine, aşağıdaki yönetmelikler ile uyumludur:
Ovaj stroj je u skladu sa sljedećim direktivama:
Stroj ustreza zahtevam sledečih direktiv:
A máquina está em conformidade com as seguintes diretivas:
Stroj je v souladu s ustanoveními následujících směrnic:

2006/42/EC (Maschinenrichtlinie, Machinery-Directive)


2014/30/EU (EMV-Richtlinie, EMC-Directive)
2011/65/EU (RoHS Richtlinie, RoHS Directive)

Die Schutzziele der Niederspannungsrichtlinie 2014/35/EU wurden gemäß Anhang I Nr. 1.5.1 der Maschinenrichtlinie 2006/42/EC eingehalten.
Protective Goals of the Low Voltage Directive 2014/35/EU are in compliance with Appendix I No 1.5.1 of the Machinery Directive 2006/42/EC.
Les objectifs de protection de la directive sur les basses tensions 2014/35/EU ont été respectés conforme à l’annexe I Nr. 1.5.1 der de la directive relative aux machines 2006/42/EC.
Directiva de protecciones de baja tension 2014/35/EU estan en acuerdo con el apendice I No 1.5.1. de la directiva de maquinaria 2006/42/EC.
Gli obiettivi di protezione della direttiva per basse tensioni 2014/35/EU è stata rispettata secondo allegato I n. 1.5.1 della Direttiva per macchine 2006/42/EC.
De veiligheidsdoelstellingen van de laagspanningsrichtlijn 2014/35/EU zijn nageleefd in overeenstemming met nr. 1.5.1 van bijlage I van de machine richtlijn 2006/42/EC.
Produkt spełnia wymogi bezpieczeństwa dyrektywy niskonapięciowej 2014/35/EU, zgodnie z załącznikiem I nr. 1.5.1 dyrektywy maszynowej 2006/42/EC.
Цели, охраняемые Директивой по высоковольтному оборудованию 2014/35/EU, соблюдены в соответствии с приложением № 1.5.1 Директивы по машинному
оборудованию 2006/42/ЕС.
Alçak Gerilim Yönetmeliği 2014/35/EU'nin koruyucu hedeflerine, Makine Yönetmeliği 2006/42/EC, ek I no. 1.5.1'e göre uyulmuştur.
Sigurnosni ciljevi direktive o niskom naponu 2014/35/EU udovoljavaju dodatku i br. 1.5.1. Direktive o strojevima 2006/42/EC
Upoštevani so zaščitni cilji Direktive o nizki napetosti 2014/35/EU v skladu s prilogo I, št. 1.5.1 Direktive o strojih 2006/42/EC.
Os objetivos de proteção da Diretiva de Baixa Tensão 2014/35/EU foram cumpridos de acordo com o Apêndice I, n.º 1.5.1 da Diretiva de Máquinas 2006/42/EC.
Cíle ochrany dle nízkonapěťové směrnice 2014/95/ES byly splněny dle přílohy I č. 1.5.1 směrnice o strojních zařízeních 2006/42/ES.

Bestätigt durch:
Confirmed by: Offenburg, 04.09.2019 ppa.

Harald Disch
Direktor Produktentwicklung Europa
Director Warewash Engineering Europe

HOBART 0000000286-001-EN / 28. Nov. 2019 33


HOBART GmbH Hobart Norge Hobart International (S) Pte Ltd
ecomax by HOBART Gamle Drammenvei 120 158, Kallang Way, #06-03/05
Robert-Bosch-Str. 17 N-1363 Høvik Singapore 349245
77656 Offenburg Tlf.: +47-67109800 Telephone: +65 6846 7117
Deutschland Fax.: +47-67109801 Fax: +65 6846 0991
Tel.: +49 (0)1803 66 29 E-post: post@hobart.no E-mail: enquiry@hobart.com.sg
Fax: +49 (0)1803 63 29.600-23 19 Hjemmeside: www.hobart.no Internet: http://www.hobart.com.sg
E-Mail: info@ecomaxbyhobart.de
Internet: www.ecomaxbyhobart.de Hobart Scandinavia ApS Hobart Thailand
Håndværkerbyen 27 43 Thai CC Tower Building,
HOBART Export 2670 Greve 31st FL, Room No. 310-311,
Robert-Bosch-Str. 17 Danmark South Sathorn Rd., Yannawa,
77656 Offenburg Tlf.: +45 4390 5012 Sathorn, Bangkok, 10120
Germany Fax.: +45 4390 5002 Thailand
Phone: +49 (0)781.600-2820 E-mail: salg@hobart.dk Telephone: +66(0)2-675-6279-81
Fax: +49 (0)781.600-2819 Internet: www.hobart.dk Fax: +66(0)2-675-6282
E-Mail: info-export@hobart.de E-mail: enquiry@hobartthailand.com
Internet: www.hobart-export.com Hobart Sweden/Finland Internet: http://www.hobartthailand.com
Tel: +46 8 584 50 920
Hobart UK. E-mail: info@hobart.se ITW India Pvt Ltd.
Southgate Way, Internet: www.hobart.se 501-502 Vipul Trade Centre
Orton Southgate, Sector 48 Sohna Road
Peterborough Australia Gurgaon 122001”
PE2 6GN Hobart Food Equipment Telephone: +91 124 4245430
United Kingdom Unit 1 / 2 Picken Street, Fax: +91 124 4245432
Tel.: +44 (0)844 888 7777 Silverwater NSW, 2128
Republic of Ireland: +353 (0)1246 0248 Tel: +61 1800 462 278
Fax: +44 (0)1733 361 347 Fax: +61 02 9714 0222
E-mail: sales@hobartuk.com E-mail: sales@hobartfood.com.au
Internet: www.hobartuk.com Internet: www.hobartfood.com.au

Compagnie HOBART SAS HOBART China


Allée du 1er mai 15th Floor, Building A
77183 Croissy Beaubourg New Caohejing International Business
FRANCE Center
Tel: +33 (0)1 64 11 60 00 391 Gui Ping Road
Fax: +33 (0)1 64 11 60 10 Shanghai, 200233
E-mail: contact@hobart.fr Telephone: +86 (0)21 34612000
Internet: www.hobart.fr Fax: +86 (0)21 34617166
Internet: www.hobartchina.com
Hobart Nederland BV
Pompmolenlaan 12 HOBART Korea LLC
3447 GK Woerden 7th Floor, Woonsan Bldg, 108, Bangi-dong
Telefoon +31 (0)348 462626 Songpa-gu, Seoul 138-050
Fax: +31 (0)348 430117 Korea
E-mail: info@hobartnederland.nl Telephone: +82 2 34 43 69 01
Internet: www.hobartnederland.nl Fax: +82 2 34 43 69 05
E-mail: contact@hobart.co.kr
Hobart Foster Belgium bvba/sprl Internet: www.hobart.co.kr
Industriestraat 6
1910 Kampenhout HOBART (Japan) K.K.
Telefoon +32 (0) 16.60.60.40 6-16-16 Minami-Oi, Shinagawa-ku,
Fax +32 (0) 16.60.59.88 Tokyo 140-0013
E-mail: info@hobart.be Japan
Internet: www.hobart.be Telephone: +81 3 5767 8670
Fax: +81 3 5767 8675
E-mail: info@hobart.co.jp
Internet: www.hobart.co.jp

Printed in Germany

34 0000000286-001-EN / 28. Nov. 2019 HOBART

You might also like