THERMO FISHER- BENGALURU- 3rd FLOOR- COMMAND CENTER- BILL OF

QUANTITIES- SUMMARY

SR. NO. DESCRIPTION OF ITEM AMOUNT


1 CIVIl & INTERIORS 1,082,580
2 ELECTRICAL WORKS 321,320
3 UPS 205,000
4 HVAC WORKS 639,553
5 SAFETY & SECURITY 272,821
TOTAL - EXCLUDING TAXES 2,521,274
BOQ- CIVIL & INTERIOR WORKS

SR.NO
. DESCRIPTION QTY. BOQ UNIT RATE (Rs.) AMOUNT (Rs.)

1 STORAGES

a) LOW HT. STORAGES IN LAMINATE WITH PLY SHELVES 128 SFT 1,200 153,600
1’-6” DEPTH x 2’-6” HEIGHT

2 Partition work

SINGLE GYPSUM BOARD PARTITIONS WITH Aluminum


FRAMEWORK WITH ACCOUSTICAL INSULATION TILL 2800
MM HT 1022 SFT 265

4 RAISED FLOORING
300 mm wide step with 150 mm high riser made out of
19mm thick ply wood 700 Sft 300 210,000

5 SOLID SHUTTERS ON HINGES WITH MORTICE LOCK AND DOOR CLOSER DOOR
75mm X 50mm Ply Door Frame Sutaible for solid door
with door closer 2 Nos 28000 56,000

6 Pannelling work

Providing & Fixing of Laquered glass panelling surrounding


the TV panel with 12mm ply wood backing 180 SFT 900 162,000

Providing & Fixing of Laminate finished wall paneling with


12mm thick ply panelling on the gypsum partition 300 Sft 300 90,000
Basic Price of Laminate: Rs. 50

3LAYERS OF 6MM FLEXI PLY PANELING WITH HI-GLOSS


347 Sft 500
LAMINATE FINISH ON Aluminum FRAMEWORK
173,500

7 MODULAR CEILING (2'-0" X 2'-0") MINERAL FIBRE.Grid Ceiling work

PROVIDING AND FIXING MODULAR CEILING TILE IN 2’ X 2’ (


0.5 NRC ARMSTRONG/ AMF MAKE WITH SILLHOUETE RFT
GRID) 0

8 Work Station
Command Center Workstation- Desking System
8 Nos 9,500
(1200MMX750MM) 76,000

BLACK OUT BLINDS FOR WINDOWS/ GLAZING (Artlite/


9 842 S.FT. 125
softline) 105,250

10 PROVIDING & FIXING OF SUN CONTROL FILM. BASIC PRICE 842 SFT 65
OF FILM- Rs. 50 PER SFT (GARVARE ) 54,730

11 Centralized Dust bins 1 No 1500 1,500

GRAND TOTAL 1,082,580


ELECTRICAL BOQ
Part A Description
Supply Installation
Amount in INR Amount in INR
AS BUILT AMOUNT

1 LT PANELS 15,840 840 16,680

3 LT CABLES & ENDTERMINATIONS 40,928 13,200 54,128

4 MCB DISTRIBUTION BOARDS 5,400 720 6,120

5 CIRCUITMAINS 32,470 7,990 40,460

6 POINT WIRING 14,667 2,732 19,641

7 POWER RECEPTACLES 23,191 4,710 27,901

8 LIGHT FIXTURES 66,444 4,360 6,760

CABLE TRAYS & RACEWAYS FOR


9 25,064 4,695 49,184
POWER

CABLE TRAYS & RACEWAYS FOR


10 25,475 4,466 10,500
NETWORKING

11 EARTHING 21,108 5,820 28,188

12 MISCELLANEOUS ITEMS 900 300 0

271,487 49,833 259,562


TOTAL FOR LOW SIDE
321,320
UPS BOQ
Qty Supply Installatio Supply Amount Installation
Sl.No Description Unit Rate in n Rate in in INR Amount in
INR INR INR

1.0 UPS & ASSOCIATED WORKS

Note :
Scope of work covers supply, unloading ,Storing ,
installation, testing and commissioning of the system
as per the technical specification & technical data
sheet, installation cost shall include testing &
commissioning also.

Necessary Copper cabling between UPS and batteries /


battery breaker etc., shall be a part of UPS tender.

Necessary Copper cabling between UPS and Isolation


transformer shall be a part of UPS tender.

UPS input & output cable from UPS power shall be


supplied & terminated by other vendors.
Necessary control cabling between different units of
UPS shall be a part of UPS offer (If required).

UPS installation cost shall include necessary MS angle


iron for UPS for bottom cable terminations as per
specfication. The angle frame shall be powder coated
with shade same as UPS.

Vendor to submit dimensional GA drawing of UPS /


Batteries along with offer.

The technical specification shall be captured in all


respect irrespective of whether it is captured in below
BOQ or not

The cost for AMC for 3 years after warranty period of 3


years of UPS shall be included in the supply cost of
UPS

Prices of Module & Frame should be fixed for Five


years
The offer to include the battery bank testing at site for
the full load
Local Annunciator for each room needs to be
considered for each UPS at BMS Room. Necessary
cabling needs to be considered in the offer

Battery Monitoring system needs to considered in the


offer

1.1 COMMAND CENTER UPS

10KVA (3phase in 1 phase out) UPS System complete


with : Rectifier / Charger, Static inverter, Static switch
& bypass changeover switch Controls, Switchgear, and
all accessories with earthing as per the broad power
scheme

12Volts batteries for 10kVA UPS with 15Mins back-up,


Sealed maintenance free, Valve regulated type.
No. 1 195000 10000 195000 10000
No. 1 195000 10000 195000 10000

Battery cabinet with suitable ventilators, copper


cables/buslinks between batteries, copper cables
between UPS & batteries, DC MCCB Box, DC isolator
panel for battery strings (DC Isolator box shall be
individual for each UPS / Battery string).

GRAND TOTAL 195000 10000


205,000
ELECTRICAL BOQ - COMMAND CENTER

Sl. No. DESCRIPTION Unit QTY Cost in INR Cost in INR

Installation Supply Installation


3F TOTAL Supply Rate
Rate Amount Amount

1.0 LT PANELS :

Panels as per technical specifications & schematic diagram.


Supply, Installation, Testing and Commissioning of Indoor type LT
Switchboards, Floor mounting type, Bottom/Top entry. Refer
enclosed SLD for component details.
Enclosure: Compartmentalized Single front CRGO (Cold rolled
grain oriented sheet steel)

Doors:2mm Body:2mm Gland:3mm covers and partitions:1.6mm

IP class:IP52 for Indoor/IP55 with weather proof enclosure for


outdoor

Bus bars: Electrolytic grade conductivity as per standard IS 5082

Bus bar Material: As per SLD


Bus bar supports: DMC/FRP/SMC
Bus bar joints: Shrouded/Tinned
Protection releases: As per SLD (Adjustable over current & short
circuit unless otherwise specified)
Ics=Icu for all breakers

Utilization category: All MCCB/ACB's shall be Cat: A except ACB's


for Ltg & raw power input distribution panel shall be with Cat: B .

Loovers: Busbar chamber shall have louvers with fine mesh inside

Shade: Epoxy powder coated RAL 7032


Design: Modular type
Cable entry: As per site condition
Bus bar insulation: Aluminum bus bars shall be bare with color
coding at the ends/Copper shall be bare with color coding at the
ends/For Humidified areas the copper bus bars shall be coated
with tin.
Note:
1. The Panel shall be fully as per the requirement of Electrical
Inspectorate/ EB authorities.
2. Auxilliary contactor to be provided along with auto-manual
switch where ever required.
3. All Breakers both Incoming & Outgoing shall have LED 'ON /
OFF / TRIP' indications without fail.
4. CTs shall be of cast resin type only.
5. All doors to have double rubber gasket with shutter assembly &
door seating frame.
6. All AC feeders will have time delays of 0-60 Seconds.
7. All MCCBs of 250A and above for non-ups loads will be
microprocessor based only and for UPS panels shall be with
thermal releases.

8. All DLMs to be of dual source meters unless otherwise specified

9. The current density for Aluminium busbars shall be 0.8 only.

10. The current density for Copper busbars shall be 1.3 only.
11. All UPS outgoing panels shall have neutral busbars double the
size of phase.
12. All MCCB's shall have plug setting from (70 -100%) for < 250A
& (40 - 100%) for > 250A
13. All Lighting / RP and Lift panels shall have ELR for incomer of
Prok. Dvs. Make only.
14. All test certificates must be provided immediately after
commissioning.
15. SAFETY CERTIFICATE FOR THE PANELS SHALL BE PRODUCED
FROM CEIG.
16. All meters shall be Digital type only.
17. FRLS PVC copper wires shall be used for control wiring

1.1 63A, 4P COS for Command Center UDB.

Incommer 1 - From 10KVA UPS in First floor No. 1 1 12,600 600 12,600 600
Incommer 2 - From UPS SMSB in First floor

2.0 4P MCB ISOLATOR with enclosures


2.1 63A Weather proof No. 1 1 3,240 240 3,240 240

Total for LT Panels 15,840 840

3 LT CABLES & ENDTERMINATIONS

Supply, Laying, Testing and Commissioning of stranded XLPE/PVC


insulated, Armoured/Unarmoured/Flexible, Aluminum / Copper
conductor, laid in tray / hume pipe / in ready made trenches, with
nylon cable ties / MS Clamps @ 600mm interval etc., as required.
The cost of the nylon tie and overlapping GI strip shall be
included in the cost of installation.

Supply, Installation, Testing and Commissioning of Compression


type cable gland, aluminum lugs for aluminum cables / copper
lugs for copper cables, insulation tape, anti corrosive paste, brass
clamps for gland earthing with 14 SWG copper wire to connect to
nearest earth flat.

Insulation: XLPE above 25Sqmm and Class A PVC below 25Sqmm

Inner sheath: Extruded PVC only for Multicore

Outer sheath: Extruded Type ST2 PVC with FLAME RETARDANT

Voltage grade:1100Volts
Armoure: Galvanized Steel strip/Wire for multicore
Non Magnetic Aluminum Wire/Strip for Single core
Gland type : Brass with nickel plated
Compression : Double compression above 35 Sq.mm

Sealing Ring : Natural rubber for indoor, Neoprene for Outdoor

3.1a 4 Core x 16 Sq. mm Mts 280 280 140 42 39,200 11,760


3.1b Endterminations Nos. 8 8 216 180 1,728 1,440

3.2a 4 Core x 10 Sq. mm Mts RO 132 46


3.2b Endterminations Nos. RO 240 115

3.3a 4 Core x 6 Sq. mm Mts RO 108 40


3.3b Endterminations Nos. RO 230 115

Total for LT Cables and Endterminations 40928 13200

4 MCB DISTRIBUTION BOARDS (DB)

Supply, Installation, Testing and Commissioning of MCB


Distribution board as per approved installation dwgs.

Wall mounted MCB DBs with MS wire way box on top / bottom &
on sides. MCBs shall be rated for 10kA with current limiting
feature. Dummy ways to be covered with blank plates. All out
going ways shall be labelled & laminated.

Enclosure:1.2mm CRCA Sheet Steel, Powder Coated


Door : Double Door
Protection : IP 42
Cable Entry : Top & Bottom

For UPS distribution ELCB's shall be harmonic resistant (SI Series)

Bus bar : Shall be tinned Copper and 200% rating for UPS DB
Neutral Link
MCB's : 10kA 'B' Curve for Lighting & Raw power, 10kA 'D' Curve
for UPS Distribution
1) Separate Earth bus/Neutral bus for each phase

2) Each Circuit shall have yellow ferrules with circuit number.

3) Accessories required for installation of DB's on


Wall/Column/Gyp Board shall be considered
4) DB's shall be covered with powder coated (paint should match
with DB Color) wire ways all around and up to ceiling to receive
incoming circuits
5) Laminated A3 OR A4 size SLD copy shall be pasted inside DB
door
6) Safe shroud for Neutral link shall be provided

Outgoing : 12Nos. 16A SP MCB of 'D' curve No. 1 1 5,400 720 5,400 720

Total for MCB Distribution boards 5400 720

5 CIRCUIT MAINS

Circuit mains using 1.1kV grade PVC insulated copper conductor


(MSCC) FRLS wires / PVC insulated PVC sheathed single core
cables drawn in 2mm thick PVC FRLS conduit or in existing
raceway. Rates quoted shall include supply of conduits, wires &
other conduiting accessories.Circuit mains shall be measured from
respective DB to the nearest point. All circuit terminations shall be
provided with solder less crimping type copper sockets / lugs,
ferrules indicating source code on load side & load code on source
side. There shall not be any joints in the circuits, only looping is
allowed in terminal blocks & at points.

1) Conduits running above false ceiling in multiples shall be


supported by Slotted GI 'C' channel at distance not more than
0.5mtrs intervals. OR else with spacers & saddles at an intervals of
0.5mtrs
2) Accessories shall includes Bends, Collars, junction boxes,
Spacers, saddles, screws, Flexibles
3) Conduits shall be ISI marked
4) The number of wires drawn in each conduit shall be as per IS
694 code.
5) No different phases shall be drawn in same conduit
6) Conduit joints shall be done with threading proper accessories
only
7) White colour conduit is required

5.1 Lighting Circuit

To wiring using 2X2.5 + 1X1.5 sqmm PVC insulated FRLS wire


drawn in 20mm dia rigid PVC conduit as lighting circuit. The
circuit main shall be measured in running metres from respective
distribution board upto first switch point and looping between Mts. 85 85 102 33 8,670 2,805
the switches (further onwards, it shall be deemed to be included
in point wiring).

5.2 Emergency Lighting Circuit :

To wiring using 3 X1.5 sqmm PVC insulated FRLS wire drawn in


20mm dia rigid PVC conduit as lighting circuit. The circuit main
shall be measured in running metres from respective distribution
board upto first switch point and looping between the Mts. 40 40 80 27 3,200 1,080
switches ( further onwards, it shall be deemed to be included in
point wiring).

5.3 Raw power & UPS power Circuit - First point


Supply & Installation of 3 C x 4 Sqmm FRLS 1100V unarmoured
double insulated flexible multicore cable in white and black Mts. 150 150 107 20 16,050 3,000
colour for UPS circuit.

5.4 Raw power & UPS power Circuit - Looping


Supply & Installation of 3 C x 2.5 Sqmm FRLS 1100V unarmoured
double insulated flexible multicore cable in white and black Mts. 65 65 70 17 4,550 1,105
colour for UPS circuit.
Total for Circuitmains 32470 7990

6 POINT WIRING

6.1 PRIMARY LIGHT POINT


Ceiling flexible conduit shall be included at the drop of light
fixture. Nos. 3 3 705 130 2,115 390

6.2 SECONDARY LIGHT POINT

` Ceiling flexible conduit shall be included at the drop of light Nos. 2 2 486 86 972 172
fixture.

6.3 PRIMARY LIGHT POINT

I. Primary light point means extending the wiring till the light
fixture with ceiling rose & complete accessories (wiring from
the DB to first light is covered under circuit mains)

II. Ceiling flexible conduit shall be included at the drop of light Nos. 5 5 756 140 3,780 700
fixture.

6.4 SECONDARY LIGHT POINT

I. Secondary light point means extention of light outlet from


existing primary point with ceiling rose & complete
accessories. Same to be controlled by the existing MCB in DB

II. Ceiling flexible conduit shall be included at the drop of light


Nos. 15 15 520 98 7,800 1,470
fixture.

Total for Point wiring 14,667 2,732

7 POWER RECEPTACLES

Supply, Installation, Testing and Commissioning of the following


Modular/Industrial Switch, sockets with modular front plate, and
accessories as per the site conditions.
The quoted rate for power socket outlets shall include
a. Socket outlets - 5pin combi/intel sockets
b. Switches
c. 14SWG metal boxes with knockout on all
sides d. Front plate of
required colours with accessories

Industrial type sockets shall be of Polycarbonate body with plug


top. All switch / sockets shall be provided with printed labels /
stickers indicating source code. Colour code for UPS socket
plates : White/ as per architect. Colour code for RP socket plates :
Black/Grey/ as per architect. All switch / sockets including front
plate & frame which will be mounted on the metal boxes shall
have removable film coat to protect from scraches & paint during
installation. - Including Cabling with 3C x 2.5 Sqmm FRLS 1100V
unarmoured double insulated flexible multicore cable of white /
Black colour

Note: Safety shutters to prevent accidental contact with live parts


shall be provided. No indicator shall be provided for switches

7.3 2x13A socket controlled by 16A switch Nos. 35 35 540 108 18,900 3,780
7.4 3x13A socket controlled by 16A switch Nos. 3 3 702 130 2,106 390
7.5 1x6/16A socket controlled by 16A switch Nos. 5 5 437 108 2,185 540
Total for Power Receptacles 23191 4710

8.0 LIGHTING

Supply, Installation, Testing and Commissioning of Light fixtures and


lamps with all accessories, fixing on the wall / ceiling/false ceiling
with wooden blocks, screws ,hardware's ,suspended chain hooks as
required as per the site conditions (including the earthing of fixture)

Light fixtures complete with accessories like control gear, low loss
(<5W ) HF Electronic ballast , HPF condensor (PF shall be >0.85 lag. ) ,
energy efficient high lumen output fluorescent tubes / CFL lamps etc.,
Note : The make & the catalogue no. mentioned here is only indicative
& any of the make mentioned in recommended list of makes is
preferred.
The electronic / Digital ballast shall be with THD < 5%. & low loss
copper ballast.

The rate shall include for fittings along with transformers where
required, diffuser, chokes, starter, power factor improvement
capacitors, wires, downrods etc., complete with all accessories to
complete the installation as required.

Lamp colour to be warm white 4500K


Driver-5 Years Warranty.
Lamps-5 Years Warranty.
Diffuser-5 Years Warranty.
Lux level calculation to be submitted along with the tender.

2 x 2 recess mounted luminaire with LED (Light Emitting Diode) 32W,


8.1 240V, white powder coated housing & frame in CRCA sheet,high Nos 20 20 3,180 200 63,600 4,000
efficiency translucence diffuser & electronic driver

21W Wall Mounted / Suspended Type LED Light fixtures for Service
8.2 Rooms. Nos 3 3 948 120 2,844 360

Total for Light Fixtures 66,444 4,360

9.0 CABLE TRAYS & RACEWAYS FOR POWER

Slotted angle GI ready made cable trays of 14SWG. Pre galvanised,


Quoted rates for installation shall include necessary anchor
fasteners / 'Slotted channel' supports @ 600mm interval etc., to
suit site conditions.

9.1a Ladder Type

100 x 50mm Size tray with support @ every 1000mm Mts. 25 25 400 50 10,000 1,250

9.1b Floor Raceway


150x 40mm Size Mts. 5 5 529 65 2,645 325

100 x 40mm Size Mts. 10 10 388 54 3,880 540

9.3 GI - Junction boxes


Junction boxes to be provided with enough supports inside the
box. Supplied height of the floor junction box to be such as to
match to the surface of the floor. Minimum height as mentioned
is 50mm and maximum may vary to suit site condition & the
screed height

200 x 200 x 50mm Size Nos. 3 3 313 75 939 225

150 x 150 x 50mm Size Nos. 5 5 270 65 1,350 325

25mm dia - Ceiling Mts. 50 50 45 15 2,250 750

25mm dia - Floor Mts. 40 40 100 32 4,000 1,280

Total for Cable trays & Raceways - Power 25064 4695

10.0 CABLE TRAYS & RACEWAYS FOR NETWORKING

Slotted angle GI ready made cable trays of 14SWG. Pre galvanised,


Quoted rates for installation shall include necessary anchor
fasteners / 'Slotted Channel' supports @ 600mm interval etc., to
suit site conditions.

Floor raceways
150 x 40mm Size Mts. 5 5 425 50 2,125 250
100 x 40mm Size Mts. 20 20 350 50 7,000 1,000

Ceiling raceways

150 x 60mm Size with support @ every 800mm Mts. 25 25 450 75 11,250 1,875

200 x 200 x 50mm Size Nos. 3 3 348 75 1,044 225

150 x 150 x 50mm Size Nos. 8 8 312 72 2,496 576


10.4.2 25mm dia - Ceiling Mts. 10 10 48 18 480 180

10.4.3 25mm dia - Floor Mts. 10 10 108 36 1,080 360

Total for Cable trays & Raceways - Networking 25475 4466

11.0 EARTHING

11.1 EARTH STRIPS


GI/Cu earth strips on cable tray or below ground as per site
condition. All Cu. Strips shall be run in pvc heat shrinkable sleeve
& mounted on insulation mounts. Cost of civil works shall be
included for strips laid below ground.

11.3.1 8 SWG GI Wire Mts. 10 10 30 15 300 150

11.3.3 25 x 6mm GI Earth flat Mts. 30 30 150 32 4,500 960

11.3.6 8 SWG Cu Wire Mts. 10 92 22 920 220

11.4.2a 1 Core x 10 Sq. mm Mts. 50 50 92 22 4,600 1,100

11.4.2b Endterminations Nos. 4 4 72 60 288 240

11.4.3 1 Core x 6Sq. mm including Terminations Mts. 50 50 78 18 3,900 900

11.4.4 1 Core x 4Sq. mm including Terminations Mts. 150 150 44 15 6,600 2,250

Total for Earthing 21108 5820

12.0 MISCELLANEOUS ITEMS

All the items shall be of IS certified


All the items shal be in line with CEIG requirement

12.13 MS Fabricated Items Kgs 10 90 30 900 300

Professional charges towards filing application, preparation of


drawings in necessary formats for approval, follow up and
arranging approval of drawings, scheme by Local electricity LS 1 - - -
authority / Electrical Inspectorate, obtaining clearance from
electricity authority / Electrical Inspectorate. CEIG approval to be
along with 4th floor

12.16 As built drawings:

Preparation and Submission of as built drawings of total work LS - -


executed (5 Sets hard and 5 Sets soft copy)

Total for Miscellaneous items 900 300


AS
AS BUILT AS BUILT AS BUILT BUILT
QTY SUPPLY INSTALL AMOU
NT
1 12600 600 13200

1 3240 240 3480

15,840 840 16,680

280 39200 11760 50960


8 1728 1440 3168

40928 13200 54128


1 5400 720 6120

5400 720 6120

85.00 8670 2805 11475

40.00 3200 1080 4280

150.00 16050 3000 19050

65.00 4550 1105 5655


32470 7990 40460

5 3525 650 4175

3 1458 258 1716

5 3780 700 4480

15 7800 1470 9270

16,563 3,078 19,641

35 18900 3780 22680


3 2106 3902496
5 2185 540 2725
23191 4710 27901
2 6360 400 6760 Board
Room

0 0 0

6,360 400 6,760

25 10000 1250 11250

12 6348 780 7128

22 8536 1188 9724

4 1252 300 1552

6 1620 390 2010

72 3240 1080 4320

100 10000 3200 13200

40996 8188 49184

12 5100 600 5700


12 4200 600 4800

0 0 0

0 0 0

0 0 0
0 0 0

0 0 0

9300 1200 10500

10 300 150 450

30 4500 960 5460

0 0 0

50 4600 1100 5700

4 288 240 528

75 5850 1350 7200

150 6600 2250 8850

22138 6050 28188

0 0 0

Included
in
OFFICE
AREA
BOQ

Included
in
OFFICE
AREA
BOQ

0 0 0
SUMMARY FOR HVAC WORKS

SNO DESCRIPTION SUPPLY INSTALLATION

1 HVAC LOW SIDE WORKS 527,402 112,151

TOTAL 527,402 112,151


GRAND TOTAL WITHOUT TAX 639,553
AS BUILT

SUPPLY INSTALLATION

211,316 87,490
298,806
BILL OF QUANTITIES -LOW SIDE WORKS

TOTAL RATE AMOUNT-INR


SNO DESCRIPTION UNIT QTY
SUPPLY INSTALLATION SUPPLY INSTALLATION
AIR CONDITIONING WORKS

Supply, Installation, Testing & Commissioning & Handing over of the following:

SHEET METAL DUCTING & ASSOCIATED WORKS

1 Sheet Metal Work using Rolastar Make with Ductmate(TDF) Flanges for all sizes
of the duct. Fabrication as per SMACNA Standards

Galvanizing shall be Class VIII – light coating of zinc, nominal 120 gm / sqm
surface area and Lock Forming Quality prime material alongwith mill test
certificates. In addition, if deemed necessary, samples of raw material, selected
at random by owner’s site representative shall be subject to approval and tested
for thickness and zinc coating at contractor’s expense.

All duct construction and installation shall be in accordance with SMACNA


standards. In addition ducts shall be factory fabricated utilizing the following
machines to provide the requisite quality of ducts.

All ducts shall be fabricated and installed in workmanlike manner, conforming to


relevant SMACNA codes.
The Duct shall be supported with specified Supports at regular intervalas as
mentioned in the technical specifications.
Ducts supports should be consider within 2 meters with slotted/MS angles
Rectangular ducting
Sheet Metal Ducting As per Specification. Pressure 500 Pa
a 26 G Ducting with Rotamate/ ductmate flanges(up to 250mm width ducts C-
Cleats can used)(0-550mm) Sqm 60 530 215 31,800 12,900
b 24 G Ducting with TDF flanges(551-900mm) Sqm 50 635 215 31,750 10,750
c 22 G Ducting with TDF flanges(901-1200mm) Sqm 30 750 215 22,500 6,450
Note:Cross talk attinuator duct quantity is added in 26 Guage duct quantity

2 Air Terminal Devices


a Powder coated, extruded aluminium, removable center core type, supply air
diffusers without volume control dampers of aluminium construction of the
following neck sizes. The diffuser shall be mounted in the GI box (not in scope),
with inlet connector suitable for flexible duct. GI Box & Flexible duct quantified
seperately

(All are of 600 x 600 MM Outer to Outer Size)


450 x 450 MM (Neck Size) Nos 12 1,566 216 18,792 2,592

b Powder coated, extruded aluminium, removable center core type, Return air
diffusers without volume control dampers of aluminium construction of the
following neck sizes.

(All are of 600 x 600 MM Outer to Outer Size)


450 x 450 MM (Neck Size) Nos 12 1,350 162 16,200 1,944

c Powder Coated grilles for supply and return distribution ( colour for the grill to b
conifremed by Arch/ PMC team before placing the order)0/15/30/45 deflection
should be considered as per GFC/ shop dwg Sqm 1 6,804 2,160 6,804 2,160

d Collar Dampers of opposed blade type made out of Aluminium alloy extrusion
with anodised matt black finish (quantity including for diffusers & grills) Sqm 0.5 4,860 2,160 2,430 1,080

e Volume Control Dampers made out of 100 x 40 x 1.55 mm thick galavanised


steel frame and blades of 1.2 mm galavanised sheet steel. Sqm 1 3,780 1,620 3,780 1,620

250 mm dia Rmt 18


300 mm dia Rmt 1
250 mm dia Nos 12
300 mm dia Nos 2

f Rigid round ducts fabricated out of 24 G/22 G sheets to be used as extention


pieces at the diffuser boxes.

250mm dia/300mm dia Rmt 1 1,836 702 1,836 702

g SPILL AIR BOXES


Supply,installation,testing & comissioning of 525 x 525 x 450 mm High Sheet
Metal Spill air boxes made out of 26 GI sheet for connecting the diffuser outlet & Nos 12 700 324 8,400 3,888
flexible connection from the main duct.

h Firesealent for AHU Room closure 3M /Hilti make passive fire protection
material-( supply & return air ducts.) Sqm 1 5,400 2,160 5,400 2,160

4 DUCT INSULATION MATERIALS


a Supply and installation of (Accoustic) Duct liner (Insulation) of specified thickness
of Elastromeric Rubber Insulation manafactured as per ASTM E 84 test & which
should also meet NFPA 90A supplementary materials for air distribution system
which should not absorbs less 0.2% water by volume (ASTM c 209), should not
support microbial growth (ASTM C1071, G21, G22) and should emit objectionable
odors (ASTM C 665) and should have thermal conductivity of 0.27 ( R - 2.78 in
3.4" thickness) and water vapor permeance of 0.10. - Class "1" Material-.All
joints of the Insulation material should be further covered with 50 mm wide 3
mm thick self adhesive tape made of similar material & Black Cotton Tape shall
not be used.

10 mm thick- Qunatity included for Cross talk attinuators also Sqm 10 864 324 8,640 3,240
b Supply and installation Thermal (Insulation) of specified thickness of Elastromeric
Rubber Insulation manafactured as per ASTM E 84 test & which should also meet
NFPA 90A supplementary materials for air distribution system which should not
absorbs less 0.2% water by volume (ASTM c 209), should not support microbial
growth (ASTM C1071, G21, G22) and should emit objectionable odors (ASTM C
665) and should have thermal conductivity of 0.27 ( R - 2.78 in 3.4" thickness) and
water vapor permeance of 0.10. Joints should be sealed with 50 mm wide 3 mm
thick self adhesive tape (Black Cotton Tape not acceptable). Class "O" Material-

9 mm thick Sqm 125 378 216 47,250 27,000


Note: Exposed duct insulation to be done at inside.

5 CBRI certified Motorized fire dampers for AHU supply & return air ducts and all
critical rooms. For further details refer technical specs. Sleevs should be consider Sqm 1 7,340 1,625 7,340 1,625
for all fire dampers

6 Actuators with Control Panel forabove Motorized fire dampers- 10 Nm Nos 1 16,000 2,700 16,000 2,700

7 CABLES and END TERMINATIONS.


Supply, laying, testing & commissioning of MS insulated MS sheathed, steel
armoured ,aluminium conductors 1100 V grade power cables. The cables shall be
laid in tray built up trench etc., Rate shall exclude the cost of tray

a Supply & Lying of 3 runs of 2.5 sq.mm HFLS Cu Wire in 19 mm dia MS Conduit
for panel to Fire dampers inside floor Rmt 20 150 55 3,000 1,100
b Supply & laying of 3 runs of 2.5 sq.mm HFLS Cu Wire in 19 mm dia MS Conduit
for Fire panel to Fire damper Rmt 40 150 55 6,000 2,200

8 Back draft damper with spol piece for all room dual units Sqm 1 5,400 2,640 5,400 2,640

9 Supply & installation of Canvas for CSU's Critical AC VRF/DX units, etc Sqm 2 12,240 2,400 24,480 4,800

10 DX SPLIT DUCTABLE UNITS - Inverter type (for command center)


Supply, Installation and commissioning of DX Type ductable ceiling mounted unit
of below mentioned capacities with indoor unit and out door unit. The indoor
unit shall comprise of forward curved fan section, motor,DX-coil, thermostatic
expansion valve, thermostat etc. The out door unit shall comprise of one or two
Inverter Compressor, one or two condenser coil with fan, necessary controls like
HP/LP cut out, drier, starters for the compressors and fan in built electrical
controls First charge of gas and oil mounting frame made out of suitable thick
M.S angle, rubber pads etc. The package should also consist of Control panels for
on/off operation. Noise level shall note exceed 55 db at 1 mtr distance from the
unit.

a SITC of 8.5 TR-3400CFM- Dx Type Ceiling Suspende Unit with R407C/R410A


refrigerant-Unit should supplied with Inverter compressor Nos 1 175,000 9,500 175,000 9,500
b SITC of Hard drawn copper pipe with 11/8" dia suction line &5/8" dia liquid line
pipe. The suction & liquid line shall be insulated with 9mm thick sleeveless nitrile
rubber insulation.The rate shall be inclusive of Electrical & Control cable
between IDU & ODU & MCB to ODU etc).Both the refrigerant lines should Rmt 30 1,300 270 39,000 8,100
provide with 2 Coates of Enamel paint.

Sequential controllers for above units 1 45,600 3,000 45,600 3,000


A/C units should be able to restart automatically after power failure/Interruption
Fire dampers shall be on/off based on respective unit operation
Automatic fault chnageover in case working unit fault
Sequential changeover of operating units with specified timings
Monitoring of high and low temperature conditions
The panel should be provided with potential free contact for fire integration
c nos
it Should generate an alarm if the unit trips or the room temperature goes
beyond the set point ,power fail,HP,LP trip
The panel should be provided with Rs 485/modbus connectivity for BMS
integration
Panel should be SMS module option
Panel should be compatible for 2 Nos of MCB's status
It should give Alarm in form of audible buzzer and indication light and SMS
This controller should monitor low pressure and high pressure of Units

11 Associated Civil Works

Chipping, chassing & Plastering the wall openings in cement mortor 1:6 of 15 mm
thick finishing to line and level with sand faced finshing at all levels, including all
leads & lifts, scaffolding, curing etc complete (for SA & RA openings in ahu rooms, sqm 2 - -
opgs for CHW pipes etc)

GRAND TOTAL 527,402 112,151


DOCUMENT : SAFETY AND SECURITY SYSTEM SUMMARY
SUPPLY ERECTION AS BUILT AMOUNT
S.NO DESCRIPTION
AMOUNT INR AMOUNT INR
1 FIRE PROTECTION SYSTEM 60,230 23,239 46845
2 FIRE ALARM SYSTEM 20,696 8,168 28864.00
3 PUBLIC ADDRESS SYSTEM 7,168 3,180 10348
4 FIRE XTINGUISHER SYSTEM
5 SIGANGE'S SYSTEM
6 ACCESS CONTROL SYSTEM 121,740 11,654 133394
7 CCTV SYSTEM 14,094 2,652 16746
SUB TOTAL 223,928 48,893 236,197
TOTAL 272,821
FIRE PROTECTION SYSTEM BOQ

AS BUILT QTY
SUPPLY ERECTION
S.NO DESCRIPTION MAKES UNIT QTY
RATE INR AMOUNT INR RATE INR AMOUNT INR
FIRE PROTECTION SYSTEM

Note
1.Existing header pipes are retained as it is.
Existing branches are modified as per the layout.
2.Existing pendent sprinklers to be removed and refixed as per the proposed layout.
3.Upright sprinklers to be considered for above false ceiling areas wherever the FC height
is ≥800mm
4.Request vendor to visit the site & quote accordingly

Supplying, installing,hydroulic testing and commissioning of Heavy grade M.S. Pipes


confirming to IS :1239 part - I with malleable specials confirming to IS:1239 part - II, such
as Tees, elbows, check nuts, unions, flanges, nipples etc. Including cutting, Welding, fixing
in / on walls / on Floors, ceiling by using suitable supports such as MS channels
1 ,angles,flats,roads as required at site with anchor fasteners,clamps,threaded TATA / JINDAL
roads,nuts,bolts,washers etc...complete. Painting the exposed with one coat of metal zinc
chromate primer with two coats of synthetic enamel paint of approved colour / shade etc.,
complete.The pipe shall be socket weld type up to 50 mm dia and butt weld type for 65
mm dia& above.

a 25mm nominal dia Rmt 34 458 15,572 195 6,630


b 32mm nominal dia Rmt 4 585 2,340 242 968
c 40mm nominal dia Rmt 6 685 4,110 292 1,752
d 50mm nominal dia Rmt 4 927 3,708 386 1,544
e 65mm nominal dia Rmt 0 - -
a) Pendent type Nos 15 320 4,800 168 2,520 15
The Rosette shall be fabricated by M.S. plate of 2mm thick and the finish shall be powder 15
a REPUTED Nos 15 105 1,575 55 825
coated and color shall be as approved by architects / clients.
Stainless steel corrugated flexible pipe(hose) for dropping sprinklers below false ceiling, 15
11 pipe shall be UL Listed, 16 bar pressure rating and 1500 mm long 25 mm dia with union / TYCO / EASY FLEX / Nos 15 1,875 28,125 600 9,000
VIKING
reducer collar, clamps etc. as required. (BRAIDED)
TOTAL WITHOUT TAX 60,230 23,239
SUPPLY AMOUNT INSTALLATION TOTAL
AMOUNT

0 0 0
0 0 0
0 0 0
0 0 0

4800 2520 7320


1575 825 2400

28125 9000 37125

34,500 12,345 46,845


DOCUMENT : FIRE ALARM SYSTEM BOQ

SUPPLY ERECTION
AS BUILT SUPPLY AMOUNT INSTALL TOTAL
S.NO DESCRIPTION MAKES UNIT QTY QTY ATION
RATE INR AMOUNT INR RATE INR AMOUNT INR AMOUN
T

SITC OF CONVENTIONAL FIRE ALARM SYSTEM


Note
1. Existing Fire alarm panel,detectors,Response indicator,modules and
devices are already available at site.
2. Vendor to visit the site and check the availability and quote
accordingly.

Supply,Installation,Testing and Commissioning of Conventional 4 3992 1140 5132


1 Photoelectric Smoke Detector with Standard base, powder coated Ravel Nos 4 998 3992.00 285 1140.00
backbox and other accessories as required and Detectors shall be UL
Listed. (ABOVE FALSE CEILING)

Supply,Installation,Testing and Commissioning of Conventional 4 3992 1140 5132


2 Photoelectric Smoke Detector with Standard base, powder coated Ravel Nos 4 998 3992.00 285 1140.00
backbox and other accessories as required and Detectors shall be UL
Listed. (BELOW FALSE CEILING)
3 SITC of Response indicator Ravel Nos 4 86 344.00 57 228.00 4 344 228 572
Supply,Installation,Testing and Commissioning of Conventional Hooter 1 741 285 1026
4 with Flasher, LED based, built in ABS housing and other accessories as Ravel Nos 1 741 741.00 285 285.00
required.
1 627 285 912
Supply,Installation,Testing and Commissioning of Conventional Manual
call point,front glass protection glass cover, SINGLE blinking and push
5 Ravel Nos 1 627 627.00 285 285.00
switch resettable type, built in ABS
housing with back box.(12-26V DC ) and other accessories as required.

150 10800 4950 15750


2C x 1.5 mm2, Stranded Copper conductor,Type A ST1 PVC POLYCAB /
6 insulated,Armoured FRLS CU Cable 650 V as per IS 1554, with GI saddle VARSHA/ Rmt 150 72 10800.00 33 4950.00
spacers every 0.3 mtr with Single compression Cable Glands,ABS Junction
Boxes (wherever required), terminals,Ferruling complete. KEI/DATA FLEX

7 25 mm dia. Rmt 5 40 200.00 28 140.00 5 200 140 340


TOTAL 20696.00 8168.00 20696.00 8168.00 28864.00
PUBLIC ADDRESS SYSTEM BOQ

S.NO DESCRIPTION MAKES UNIT

SITC OF PUBLIC ADDRESS SYSTEM

SITC of 6W RMS False Ceiling Mount Speakers with inbuilt 100V Line
Matching Transformer, wide opening angle, optimized for music &
speech applications with mounting clamps as per specifications
BOSCH/AHUJA/
1 - Max Power: 8W,Rated Power: 6Watts, Power Tapping: 6/3/1.5W HONEYWELL Nos
- Effective frequency range(-10 dB) : 150 Hz to 15KHz
- SPL at rated power (1Khz at 1 m) 108 dB
- Opening Angle 1 KHz / 4 KHz (-6 dB): 180/45

Supply and laying of 2C x 1.5 mm2, Stranded Copper conductor,Type


A ST1 PVC insulated,Armoured FRLS Cable 650 V as per IS 1554, with POLYCAB /
2 GI saddle spacers every 0.3 mtr with Single compression Cable VARSHA/ Rmt.
Glands,ABS Junction Boxes (wherever required), terminals,Ferruling KEI/DATA FLEX
complete.
TOTAL WITHOUT TAX
SYSTEM BOQ

SUPPLY ERECTION
AS BUILT SUPPLY
TOTAL QTY QTY AMOUN
RATE INR AMOUNT INR RATE INR AMOUNT INR T

4 2848

4 712 2848 285 1140

60 4320

60 72 4320 34 2040

7168 3180 7168


INSTALL TOTAL
ATION
AMOUN
T

1140 3988

2040 6360

3180 10348
CCTV SYSTEM BOQ

SUPPLY ERECTION
AS BUILT SUPPLY
SI.No Descriptions Makes Unit Total Qty QTY AMOUN
RATE INR AMOUNT INR RATE INR AMOUNT INR T

CCTV SYSTEM

Note
1. Software must run on either window 8 or 10. No older versions accepted
2. Consider necessary software, accessories as required for CCTV

1 10944
IP Dome camera 2 MP HD 1080P with 1/3" CCD/CMOS, Progressive/De-interlace,
Very High Definition resolution (1920x1080), Dual streaming, 25 FPS, min one H.264
stream & one H.264/MPEG 4 stream compression support, 2.7-12mm lens, 0.1 lux,
Tamper detection with built in WDR & automatic back light compensation circuitry Hikvision/Dahua/UN Nos
1 with camera manufacturer's power supply unit. The camera shall be capable of 1 10,944 10,944 627 627
operating on both POE and an UPS power source . Camera shall be along with V/Honeywell
Suitable adaptor with 3 meter cable.
The camera shall be equipped with in built 32GB memory card
Camera shall be along with camera mounting pole/back box and accessories

Supply and laying of CAT6 cable in already laid PVC FRLS Conduits 45 1260
2 (this item inclusive of necessary patch cords,I/O's & terminations for connecting AMP/KEI/POLYCAB/ Mts 45 28 1,260 17 765
camera with network switch) VARSHA

Supply and laying of 1" - 2 mm thick FRLS - PVC Conduits,JB's in wall, columns, VIP/PRECISION/AST Mts 45 1890
3 45 42 1,890 28 1,260
ceiling etc., including associated civil works. RA/ANCHOR

TOTAL 14,094 2,652 14,094


INSTALL TOTAL
ATION
AMOUN
T

627 11571

765 2025

1260 3150

2,652 16,746
ACCESS CONTROL SYSTEM BOQ

S.NO DESCRIPTION MAKES UNIT QTY

ACCESS CONTROL SYSTEM - LENEL MAKE

Supply, Installation, Testing and Commssioining of


2 reader controller, power supply unit, TCP IP
connectivity with tamper detection provision as
per the tender specifications.Cost should inclusive LENEL
1 of enclosure and power supply unit for controller 1320 Nos 1
& EM lock (power supply unit shall inclusive of
battery backup for 12 hrs).

Supply, installation, testing & commissioning of


proximity card readers with 2.5mm thick SS front
plate as per specification suitable for mounting
2 HID Nos 2
on metal surface/metal frames or wooden frames
wall or as required based on site conditions
including all accessories.

Supply, Installation, Testing and Commssioining of


3 Electromagnetic Lock with required mounting Bell, SDC, Nos 1
brackets for single door as per the tender ASSA ABLOY
specifications

Supply, Installation, Testing and Commssioining of


surface / flush mounted (as required at site) Sentrol,
4 Magnetic Contact (Door position sensor) for Secoalarm, Nos 1
access controlled doors as per the tender Ademco
specifications

Supply and laying of 4 core 1.0 Sq mm Un


Armoured Shielded FRLS, Multistanded Copper
Conductor, PVC sheathed Cable for connecting
controller to Lock & door position sensors,
Buzzer,BGU,Pushbutton as per the tender
5 Cables - Mts 80
specifications
Rate shall inclusive of 2mm thick suitable dia FRLS Polycab/Var
PVC conduits with ,JB's in wall, columns, ceiling sha /
etc., including associated civil works. (conduits & Deepanjan /
cables - blue color) V-Cables
/RAJANIGHA
NDA / Power
flex
Conduit -
BEC / VIP /
Precision/Bh
arat
sha /
Deepanjan /
V-Cables
/RAJANIGHA
NDA / Power
flex
Supply and laying of 8 core x 1 Sq mm Un Conduit -
Armoured Shielded FRLS, Multistanded Copper BEC / VIP /
Conductor, PVC sheathed Cable Precision/Bh
for connecting controller to readers as per the arat
6 tender specifications Mts 80
Rate shall inclusive of 2mm thick suitable dia FRLS
PVC conduits with ,JB's in wall, columns, ceiling
etc., including associated civil works. (conduits &
cables - blue color)

Supply, Installation, Testing and Commissioning of VAISHNO /


7 Buzzer for access controlled doors as specified Nos 1
in the Tender Specifications EQUIVALENT

KAC,EUROPL
8 Supply installation, testing, commissioning of EDR EX, Nos 1
(EMERGENCY BREAK GLASS ) SENTROL,
RAVEL
TOTAL
M BOQ
SUPPLY ERECTION
AS BUILT SUPPLY INSTALL TOTAL
QTY AMOUNT ATION
RATE INR AMOUNT INR RATE INR AMOUNT INR AMOUN
T

82,080 82,080 1,710 1,710 1 82,080 1,710 83,790

7,809 15,618 399 798 2 15,618 798 16,416

5,130 5,130 627 627 1 5,130 627 5,757

400 400 171 171 1 400 171 571

90 7,200 50 4,000 80 7,200 4,000 11,200


130 10,400 50 4,000 80 10,400 4,000 14,400

171 171 63 63 1 171 63 234

741 741 285 285 1 741 285 1,026

121,740 11,654 121,740 11,654 133,394