Command Center - As Built 7 AUG 2018
Command Center - As Built 7 AUG 2018
Command Center - As Built 7 AUG 2018
QUANTITIES- SUMMARY
SR.NO
. DESCRIPTION QTY. BOQ UNIT RATE (Rs.) AMOUNT (Rs.)
1 STORAGES
a) LOW HT. STORAGES IN LAMINATE WITH PLY SHELVES 128 SFT 1,200 153,600
1’-6” DEPTH x 2’-6” HEIGHT
2 Partition work
4 RAISED FLOORING
300 mm wide step with 150 mm high riser made out of
19mm thick ply wood 700 Sft 300 210,000
5 SOLID SHUTTERS ON HINGES WITH MORTICE LOCK AND DOOR CLOSER DOOR
75mm X 50mm Ply Door Frame Sutaible for solid door
with door closer 2 Nos 28000 56,000
6 Pannelling work
8 Work Station
Command Center Workstation- Desking System
8 Nos 9,500
(1200MMX750MM) 76,000
10 PROVIDING & FIXING OF SUN CONTROL FILM. BASIC PRICE 842 SFT 65
OF FILM- Rs. 50 PER SFT (GARVARE ) 54,730
Note :
Scope of work covers supply, unloading ,Storing ,
installation, testing and commissioning of the system
as per the technical specification & technical data
sheet, installation cost shall include testing &
commissioning also.
1.0 LT PANELS :
Loovers: Busbar chamber shall have louvers with fine mesh inside
10. The current density for Copper busbars shall be 1.3 only.
11. All UPS outgoing panels shall have neutral busbars double the
size of phase.
12. All MCCB's shall have plug setting from (70 -100%) for < 250A
& (40 - 100%) for > 250A
13. All Lighting / RP and Lift panels shall have ELR for incomer of
Prok. Dvs. Make only.
14. All test certificates must be provided immediately after
commissioning.
15. SAFETY CERTIFICATE FOR THE PANELS SHALL BE PRODUCED
FROM CEIG.
16. All meters shall be Digital type only.
17. FRLS PVC copper wires shall be used for control wiring
Incommer 1 - From 10KVA UPS in First floor No. 1 1 12,600 600 12,600 600
Incommer 2 - From UPS SMSB in First floor
Voltage grade:1100Volts
Armoure: Galvanized Steel strip/Wire for multicore
Non Magnetic Aluminum Wire/Strip for Single core
Gland type : Brass with nickel plated
Compression : Double compression above 35 Sq.mm
Wall mounted MCB DBs with MS wire way box on top / bottom &
on sides. MCBs shall be rated for 10kA with current limiting
feature. Dummy ways to be covered with blank plates. All out
going ways shall be labelled & laminated.
Bus bar : Shall be tinned Copper and 200% rating for UPS DB
Neutral Link
MCB's : 10kA 'B' Curve for Lighting & Raw power, 10kA 'D' Curve
for UPS Distribution
1) Separate Earth bus/Neutral bus for each phase
Outgoing : 12Nos. 16A SP MCB of 'D' curve No. 1 1 5,400 720 5,400 720
5 CIRCUIT MAINS
6 POINT WIRING
` Ceiling flexible conduit shall be included at the drop of light Nos. 2 2 486 86 972 172
fixture.
I. Primary light point means extending the wiring till the light
fixture with ceiling rose & complete accessories (wiring from
the DB to first light is covered under circuit mains)
II. Ceiling flexible conduit shall be included at the drop of light Nos. 5 5 756 140 3,780 700
fixture.
7 POWER RECEPTACLES
7.3 2x13A socket controlled by 16A switch Nos. 35 35 540 108 18,900 3,780
7.4 3x13A socket controlled by 16A switch Nos. 3 3 702 130 2,106 390
7.5 1x6/16A socket controlled by 16A switch Nos. 5 5 437 108 2,185 540
Total for Power Receptacles 23191 4710
8.0 LIGHTING
Light fixtures complete with accessories like control gear, low loss
(<5W ) HF Electronic ballast , HPF condensor (PF shall be >0.85 lag. ) ,
energy efficient high lumen output fluorescent tubes / CFL lamps etc.,
Note : The make & the catalogue no. mentioned here is only indicative
& any of the make mentioned in recommended list of makes is
preferred.
The electronic / Digital ballast shall be with THD < 5%. & low loss
copper ballast.
The rate shall include for fittings along with transformers where
required, diffuser, chokes, starter, power factor improvement
capacitors, wires, downrods etc., complete with all accessories to
complete the installation as required.
21W Wall Mounted / Suspended Type LED Light fixtures for Service
8.2 Rooms. Nos 3 3 948 120 2,844 360
100 x 50mm Size tray with support @ every 1000mm Mts. 25 25 400 50 10,000 1,250
Floor raceways
150 x 40mm Size Mts. 5 5 425 50 2,125 250
100 x 40mm Size Mts. 20 20 350 50 7,000 1,000
Ceiling raceways
150 x 60mm Size with support @ every 800mm Mts. 25 25 450 75 11,250 1,875
11.0 EARTHING
11.4.4 1 Core x 4Sq. mm including Terminations Mts. 150 150 44 15 6,600 2,250
0 0 0
0 0 0
0 0 0
0 0 0
0 0 0
0 0 0
0 0 0
0 0 0
Included
in
OFFICE
AREA
BOQ
Included
in
OFFICE
AREA
BOQ
0 0 0
SUMMARY FOR HVAC WORKS
SUPPLY INSTALLATION
211,316 87,490
298,806
BILL OF QUANTITIES -LOW SIDE WORKS
Supply, Installation, Testing & Commissioning & Handing over of the following:
1 Sheet Metal Work using Rolastar Make with Ductmate(TDF) Flanges for all sizes
of the duct. Fabrication as per SMACNA Standards
Galvanizing shall be Class VIII – light coating of zinc, nominal 120 gm / sqm
surface area and Lock Forming Quality prime material alongwith mill test
certificates. In addition, if deemed necessary, samples of raw material, selected
at random by owner’s site representative shall be subject to approval and tested
for thickness and zinc coating at contractor’s expense.
b Powder coated, extruded aluminium, removable center core type, Return air
diffusers without volume control dampers of aluminium construction of the
following neck sizes.
c Powder Coated grilles for supply and return distribution ( colour for the grill to b
conifremed by Arch/ PMC team before placing the order)0/15/30/45 deflection
should be considered as per GFC/ shop dwg Sqm 1 6,804 2,160 6,804 2,160
d Collar Dampers of opposed blade type made out of Aluminium alloy extrusion
with anodised matt black finish (quantity including for diffusers & grills) Sqm 0.5 4,860 2,160 2,430 1,080
h Firesealent for AHU Room closure 3M /Hilti make passive fire protection
material-( supply & return air ducts.) Sqm 1 5,400 2,160 5,400 2,160
10 mm thick- Qunatity included for Cross talk attinuators also Sqm 10 864 324 8,640 3,240
b Supply and installation Thermal (Insulation) of specified thickness of Elastromeric
Rubber Insulation manafactured as per ASTM E 84 test & which should also meet
NFPA 90A supplementary materials for air distribution system which should not
absorbs less 0.2% water by volume (ASTM c 209), should not support microbial
growth (ASTM C1071, G21, G22) and should emit objectionable odors (ASTM C
665) and should have thermal conductivity of 0.27 ( R - 2.78 in 3.4" thickness) and
water vapor permeance of 0.10. Joints should be sealed with 50 mm wide 3 mm
thick self adhesive tape (Black Cotton Tape not acceptable). Class "O" Material-
5 CBRI certified Motorized fire dampers for AHU supply & return air ducts and all
critical rooms. For further details refer technical specs. Sleevs should be consider Sqm 1 7,340 1,625 7,340 1,625
for all fire dampers
6 Actuators with Control Panel forabove Motorized fire dampers- 10 Nm Nos 1 16,000 2,700 16,000 2,700
a Supply & Lying of 3 runs of 2.5 sq.mm HFLS Cu Wire in 19 mm dia MS Conduit
for panel to Fire dampers inside floor Rmt 20 150 55 3,000 1,100
b Supply & laying of 3 runs of 2.5 sq.mm HFLS Cu Wire in 19 mm dia MS Conduit
for Fire panel to Fire damper Rmt 40 150 55 6,000 2,200
8 Back draft damper with spol piece for all room dual units Sqm 1 5,400 2,640 5,400 2,640
9 Supply & installation of Canvas for CSU's Critical AC VRF/DX units, etc Sqm 2 12,240 2,400 24,480 4,800
Chipping, chassing & Plastering the wall openings in cement mortor 1:6 of 15 mm
thick finishing to line and level with sand faced finshing at all levels, including all
leads & lifts, scaffolding, curing etc complete (for SA & RA openings in ahu rooms, sqm 2 - -
opgs for CHW pipes etc)
AS BUILT QTY
SUPPLY ERECTION
S.NO DESCRIPTION MAKES UNIT QTY
RATE INR AMOUNT INR RATE INR AMOUNT INR
FIRE PROTECTION SYSTEM
Note
1.Existing header pipes are retained as it is.
Existing branches are modified as per the layout.
2.Existing pendent sprinklers to be removed and refixed as per the proposed layout.
3.Upright sprinklers to be considered for above false ceiling areas wherever the FC height
is ≥800mm
4.Request vendor to visit the site & quote accordingly
0 0 0
0 0 0
0 0 0
0 0 0
SUPPLY ERECTION
AS BUILT SUPPLY AMOUNT INSTALL TOTAL
S.NO DESCRIPTION MAKES UNIT QTY QTY ATION
RATE INR AMOUNT INR RATE INR AMOUNT INR AMOUN
T
SITC of 6W RMS False Ceiling Mount Speakers with inbuilt 100V Line
Matching Transformer, wide opening angle, optimized for music &
speech applications with mounting clamps as per specifications
BOSCH/AHUJA/
1 - Max Power: 8W,Rated Power: 6Watts, Power Tapping: 6/3/1.5W HONEYWELL Nos
- Effective frequency range(-10 dB) : 150 Hz to 15KHz
- SPL at rated power (1Khz at 1 m) 108 dB
- Opening Angle 1 KHz / 4 KHz (-6 dB): 180/45
SUPPLY ERECTION
AS BUILT SUPPLY
TOTAL QTY QTY AMOUN
RATE INR AMOUNT INR RATE INR AMOUNT INR T
4 2848
60 4320
60 72 4320 34 2040
1140 3988
2040 6360
3180 10348
CCTV SYSTEM BOQ
SUPPLY ERECTION
AS BUILT SUPPLY
SI.No Descriptions Makes Unit Total Qty QTY AMOUN
RATE INR AMOUNT INR RATE INR AMOUNT INR T
CCTV SYSTEM
Note
1. Software must run on either window 8 or 10. No older versions accepted
2. Consider necessary software, accessories as required for CCTV
1 10944
IP Dome camera 2 MP HD 1080P with 1/3" CCD/CMOS, Progressive/De-interlace,
Very High Definition resolution (1920x1080), Dual streaming, 25 FPS, min one H.264
stream & one H.264/MPEG 4 stream compression support, 2.7-12mm lens, 0.1 lux,
Tamper detection with built in WDR & automatic back light compensation circuitry Hikvision/Dahua/UN Nos
1 with camera manufacturer's power supply unit. The camera shall be capable of 1 10,944 10,944 627 627
operating on both POE and an UPS power source . Camera shall be along with V/Honeywell
Suitable adaptor with 3 meter cable.
The camera shall be equipped with in built 32GB memory card
Camera shall be along with camera mounting pole/back box and accessories
Supply and laying of CAT6 cable in already laid PVC FRLS Conduits 45 1260
2 (this item inclusive of necessary patch cords,I/O's & terminations for connecting AMP/KEI/POLYCAB/ Mts 45 28 1,260 17 765
camera with network switch) VARSHA
Supply and laying of 1" - 2 mm thick FRLS - PVC Conduits,JB's in wall, columns, VIP/PRECISION/AST Mts 45 1890
3 45 42 1,890 28 1,260
ceiling etc., including associated civil works. RA/ANCHOR
627 11571
765 2025
1260 3150
2,652 16,746
ACCESS CONTROL SYSTEM BOQ
KAC,EUROPL
8 Supply installation, testing, commissioning of EDR EX, Nos 1
(EMERGENCY BREAK GLASS ) SENTROL,
RAVEL
TOTAL
M BOQ
SUPPLY ERECTION
AS BUILT SUPPLY INSTALL TOTAL
QTY AMOUNT ATION
RATE INR AMOUNT INR RATE INR AMOUNT INR AMOUN
T