Chapter 10 - Special Hazards

Download as pdf or txt
Download as pdf or txt
You are on page 1of 28

FIRE_Ch10_Special_Hazards:Layout 1 19/12/2013 16:20 Page 1

Chapter 10 - Special Hazards

Special Hazards

Introduction
Tyco Fire Protection Products manufacturers and provides a
wide range of equipment suitable for use in hazardous
areas both onshore and offshore where normal equipment
cannot be safely used.

The range includes Instrinsically Safe point detectors for


use on conventional and Digital Addressable systems and
extends to Flameproof and I.S. flame detectors with
multiple interface options for use in the most demanding of
environments.

A complete range of Barriers, Housings, Callpoints and


Sounders are available to fully support the product range.

12/13 Fire Catalogue Chapter 10 Page 1


FIRE_Ch10_Special_Hazards:Layout 1 19/12/2013 16:20 Page 2

Chapter 10 - Special Hazards

Special Hazard Flame Detectors


Features
• Reliability Choice of IR array or enhanced Triple IR solar blind
technologies allow users to tailor their systems to provide
reliable and fast fire detection.
• Fast Acting FLAMEVision reacts to minimise the effect of fire
and improve life safety through detection with less disruption
and downtime.
• Accuracy Event location information will pin point fire using
the IR array to allow targeted shutdown and suppression.
• Operator verification The optional built-in video camera
assists operator verification and ensures optimum actions are
taken. Additional benefit of post event analysis and to aid and
verify alignment.
• Optimum protection in all weather conditions FLAMEVision
maintains sensitivity using the enhanced IR sensors through
heavy rain, snow, fog and morning dew.
• Use in Hazardous explosive atmospheres FLAMEVision
is approved for protection regardless of area classifications
for all applications throughout the facility.
• Reduced spares inventory and simpler maintenance
Intrinsically safe, low cost and easy to use test equipment
simplifies maintenance and reduces service costs. Universal
mechanical mounting and cabling arrangements makes
FLAMEVision installation friendly.
• Easy integration FLAMEVision interconnects to site control
and safety systems via a range of standard industrial
interfaces.
• Dynamic masking FLAMEVision maintains detection
coverage even when a flame is part of the process being
protected.
• Complete piece of mind FLAMEVision detectors continually
monitor all electronics and perform regular optical window
tests.

FLAMEVision Flame Detectors


The FLAMEVision flame detectors use patented IR array and
triple IR solar blind technologies to provide reliable and cost
effective fire detection solutions. FLAMEVision can be
trusted in high dependency situations where fast acting and
accurate flame detection is essential. FLAMEVision
detectors offer superior performance in all weather
conditions and all lighting situations with the added benefit
of fire event location information provided by the IR array.

FLAMEVision can protect all hydrocarbon risks in classified


hazardous explosive and non hazardous atmospheres.
There is a wide range of system design options available
with flexible monitoring and control interfaces and integrated
video camera for verification purposes. Installation and
maintenance procedures are easy and efficient, minimising
the lifetime cost of ownership and reducing the need for
complex test equipment and high level operator training.

Chapter 10 Page 2 Fire Catalogue 12/13


FIRE_Ch10_Special_Hazards:Layout 1 19/12/2013 16:20 Page 3

Chapter 10 - Special Hazards


FLAMEVision FV300 FLAMEVision FV400
FLAMEVision FV300 uses Infra-Red Array based sensing FLAMEVision FV400 uses Triple IR Solar Blind technology
technology to provide the ultimate programmable flame for flame detection. This provides a reliable and cost
detector. An array of 256 infra-red sensors plus two optical effective solution in standard flame detection applications
channels view the protected area. Powerful algorithms especially where there is a single hazard in the field of view.
running on a Digital Signal Processor (DSP) are tuned to the The FV400 FLAMEVision detectors use Triple IR Solar Blind
characteristics of a fire and analyse the signals from these sensing technology and flame detection algorithms to
provide high performance sensing capabilities for
channels to quickly and reliably identify fires. A key hydrocarbon fires. This includes the ability to reliably sense
advantage of using an array is that the detector can flames through high densities of solvent vapours and black
accurately identify the location of the flame within the field of smoke, increasing the probability of early detection with
view. The location information is used to overlay a marker on consistent high sensitivity to flame throughout the whole
the live video output to highlight the fire location. The user field of view. They also ensure consistent detection of many
can quickly see the location of one fire or multiple fires and different types of hydrocarbon fuels from alcohol to aviation
decide on the appropriate action. The location information is fuel. Multiple interfaces are provided with the option of an
also available on the field network interface. User defined integral CCTV camera to provide a visual means of operator
areas within the field of view can be masked and un-masked verification.
dynamically to improve reliability and maintain maximum
coverage at all times. The detector can be supplied with an Features
optional integral colour video camera to display a live image
• Triple IR solar blind sensing technology
of the field of view, this is in addition to the alarm location
• Multiple Field Interfaces
and status information which is available as standard on the
• Detection range: Up to 65m for 0.1m2 n-heptane pan fire
video output.
• Automatic optical path monitoring,
• Integral flame simulation and remote walk test help
Features reduce the on going life time cost of the flame detecti
• Advanced array based detector installation
• Powerful signal processing on DSP with algorithms to give • Video verification via the integrated optional flameproo
reliable flame detection camera
• Detection range: Over 50m for 0.1m2 n-heptane pan fire
• Field of view: 90° horizontal, 85° vertical with full range
maintained
• High immunity to false alarms
• Solar blind
• Masking of areas in field of view
• Automatic optical path monitoring
• Advanced self test and service features
• Built-in video camera (option): View protected area with
alarm location and status overlay
• IEC 61508 Approved (SIL2)

12/13 Fire Catalogue Chapter 10 Page 3


FIRE_Ch10_Special_Hazards:Layout 1 19/12/2013 16:20 Page 4

Chapter 10 - Special Hazards


Technical Specifications FV400
Mechanical - Detector Modbus
Dimension: 155.5mm (6.1”) H x 153mm (6”) 4-20mA Sink or source
W x 92mm (3.6”) D Conventional detector I/F
Weight : 4 kg 8.8 Lb Tyco MZX Digital
Gland entry: 2 x M20 Fire & fault relay contacts NO or NC
Material: Stainless steel 316L, ANC4BFCLC Composite Video o/p (Camera option only)
to BS3146: Part 2 Hart interface *
Guard/label plate:Stainless steel 316S16 to BS
1449: Part 2 Electrical
Screws external: Stainless steel 316 A4 FV300
Detection window:Sapphire Supply voltage: 20 to 30 Vdc
Camera window: Toughened glass Current consumption (max):
196mA quiescent, 205mA Alarm
Mechanical - Bracket (24 Vdc)
Dimension: 181mm (7.2”) H x 125mm (5”) W Heater: 90mA@24vdc
x 95mm (3.75”) D Connections: 2.5mm2 (14AWG) Terminals
Material: Stainless steel 316S16 to BS
1449: Part 2 FV400
Weight: 1.54 kg 3.2 Lb Supply voltage: 15 to 30 Vdc
Current consumption:
Environmental 12mA quiescent 22mA Alarm
Operating temp: -40°C to +80°C (24Vdc - interface dependant)
Storage temp: -40°C to + 80°C Camera: 185mA @24vdc
Operating temp of camera: Heater: 90mA@24vdc
-10°C to +50°C External supply required only for camera, heater or MOD-
Storage temp with camera: BUS options
-20°C to + 70°C Connections: 2.5mm2 (14AWG) Terminals
(operating temperature is reduced for T5
* - Feature implemented by future field software update
risks)
Relative humidity :99% (non condensing)
Enclosure: IP 66 Product Codes
516.300.006 FV311S Infrared array flame detector
Flameproof certification: 516.300.008 FV311SC Infrared array flame detector -
ATEX Ex II 2 G D , IECEx & FM (FV400 pending FM PAL camera
approval) 516.300.007 FV311SC-N Infrared array flame detector -
NTSC camera
EN54 Approval 516.300.411 FV411f Triple infrared flame detector
CPD EN54-10:2002 + A1:2005 516.300.412 FV412f Triple infrared flame detector
FV400 is classified as Class 1 on the Extended and Normal with PAL camera
range settings. 516.300.413 FV413f Triple infrared flame detector
FV400 is certified as Class 3 on the Half range setting. with NTSC camera
FV300 is classified as Class 1
Ancillary equipment
Camera Specification 517.300.001 MB300 FLAMEVision mounting
Composite video: (1V p-p) into 75 Ohm via twisted bracket
pair balum 517.300.002 WH300 FLAMEVision weather hood
Horizontal resolution: Standard 450 TVL 517.300.021 WT300 FLAMEVision walk test tool
Light sensitivity (-30 IRE): 0.3 Lux 517.300.022 CTI300 FLAMEVision off-line
configuration tool
Detector performance 517.300.024 CTI400 FLAMEVision off-line
Range (0.1m² n heptane): configuration tool
FV400 65m, FV300 50m 517.300.006 MK300 FLAMEVision field spares kit
Field of view: 90° horizontal, 85° vertical 517.300.003 ADP300 Adaptor plate to mount
FlameVision device to existing
Interfaces S200 mounting bracket
FV300
Modbus
4-20mA Sink or source
Fire & fault relay contacts NO or NC
Composite video o/p

Chapter 10 Page 4 Fire Catalogue 12/13


FIRE_Ch10_Special_Hazards:Layout 1 19/12/2013 16:20 Page 5

Chapter 10 - Special Hazards


Features
• Triple waveband infrared solar blind flame detection for
optimum false alarm immunity
• Unrivalled black body rejection over a wide range of
source temperatures
• Range adjustable to 50 metres for a 0.1m2 petrol pan fire
• Discrimination of optical faults (dirty windows) from other
faults by the built-in self test feature
• Housing designed for easy installation of cabling
• Models also available with relay or 4-20mA outputs
• Patented dual filter for complete solar blindness
• 100° field of view on IS versions
• 90° field of view on Flameproof versions
• ATEX, IECEX & FM Approval

S200 Plus Triple IR Solar Blind Flame Detector-IEC 61580 Approved (SIL2)
Unlike other flame detectors on the market the MINERVA The flameproof models are suffixed by the letter " f " and are
S200 PLUS is available in both Intrinsically Safe (EEx ia) and ATEX Certified EEx d IIC T6. The detectors are suitable for
Flameproof (EEx d) models. zones 1 and 2 where group IIC gases or lesser hazards can
be intermittently present in explosive concentrations.
The intrinsically safe models are suffixed by the letter " i "
and are ATEX Certified EEx ia IIC T5. As part of an
intrinsically safe circuit, it is suitable for zones 0,1 and 2
where group IIC gases or lesser hazards can be
continuously present in explosive concentrations.

Technical Specification Product Codes


Detector Material: Stainless Steel 316L/316 517.001.266 S200+ Spares Kit & Sealant
Dimensions: 167H x 167W x 89D MM 517.001.263 S200+ Weather Protection Assembly
Weight: 4.5Kg 517.001.184 S200+ Detector Mounting Bracket
Gland Entry: 2 x 20mm
Range: 0.1m2 petrol at 50m Datasheet - Product Code PSF102U “Minerva S200 Plus Series”
0.4m2 petrol at 60m
Operating Temp:
Intrinsically Safe= - 40o c to +80o c (IECEX & ATEX)
Flame Proof= - 20o c to +60o c/+80o c
(IECEX/ATEX)
Response Time: Field Selectable 3, 6 and 12s
Sensitivity: 3 range settings
Relative Humidity: 95% (100% intermittent)
Enclosure: IP 66 and IP 67

Approvals
Various models are certified by a number of approval
bodies including those listed below.

ATEX Approved models have a suffix ‘1’ as the third digit.


FM Approved models have a suffix ‘2’ as the third digit.

12/13 Fire Catalogue Chapter 10 Page 5


FIRE_Ch10_Special_Hazards:Layout 1 19/12/2013 16:20 Page 6

Chapter 10 - Special Hazards

S200 Plus Triple IR Solar Blind Flame Detector

Additional Features
• Flexible mounting and angular adjustment
• 2 x 20mm field cable entries
• IP66/67 housing designed for external use
• Rugged 316 stainless steel housing and mounting bracket
• Variable response times and sensitivity settings
• Remote self test and range setting
• True window test in detection area (i.e. not in the edge of the
window)
• Terminals provided for Remote LED connection where relevant
• BASEEFA (CENELEC) certified
• Approved to EN54 Pt 10 (Except FV282F)
• IEC 61508 Approved (SIL2)
• FM, DNV and LRS certified
• Very low power consumption (0.35mA)
• Models available with Conventional or Analogue Addressable
interface (requires 2 core cable only)

Approvals
Interface ATEX FM Product Codes
Conventional 4-20mA MZX Addressable Relay Ex ‘ia’ Ex ‘d’ Ex ‘d’
S231i+ 4 4 516.037.004
S231f+ 4 4 516.037.003
S232f+ 4 4 516.037.015
S241i+ 4 4 516.038.004
S241f+ 4 4 516.038.003
S261f+ 4 4 516.040.002
S271i+ 4 4 516.041.004
S271f+ 4 4 516.041.003
FV282F+ 4 4 4 516.040.014

Chapter 10 Page 6 Fire Catalogue 12/13


FIRE_Ch10_Special_Hazards:Layout 1 19/12/2013 16:20 Page 7

Chapter 10 - Special Hazards

System 800 Fire Detection for Hazardous Areas


Features
• Addressable I.S. MX Technology
• Compatible with S271i+ flame detector
• Compatible I.S. callpoint.
• ATEX certified intrinsically safe Ex II 1 GD System
• Suitable for use in Zone 0, 1, 2, 20, 21 & 22

System 800 Fire Detection for Hazardous Areas


A complete range of ATEX and ICEX certified detectors suitable In order that an Installation will comply with the ATEX
for use in Zone 0, 1, 2, 20, 21 & 22 Areas. MX digital certification designated for each system, it is essential that
addressable for use on Minerva MX Fire Controllers. the certified devices are connected with cables of the
specified limits. These limits have been certified for specific
There is a risk of fire or explosion in all areas containing classifications of hazard in order that energy storage is
flammable substances in the form of liquids, gasses, dust or limited.
materials. Where these combustible materials are mixed with air
in sufficient concentration they form a flammable atmosphere The number of devices connected to the barrier and located
and the areas containing them are designated Hazardous in the Hazardous Area must always be limited to not more
Areas. When a source of ignition, such as a spark, is applied in than the listed maximum.
a hazardous area, an explosion could take place. Electrical
equipment supplied for use in Hazardous Areas must comply The use of the MX designer Software tool will ensure correct
with requirements to ensure that its introduction into the area loop loading and it’s use is essential to the design process.
does not increase the existing risk. System 800 is an MX
TechnologyTM Intrinsically Safe (I.S) system for use in Hazardous System 800 is for use in MX Technology Addressable Fire
Areas which can be connected to the MX Fire Detection detection circuits.
Systems installed in the Safe Areas.
Datasheet PSF129U
The System designer must be familiar with ATEX certification Manual 17A-02-DETEx
and have successfully completed an appropriate recognised
course in Intrinsic Safety. Design of the system requires that
the designer has all the information concerning the
installation correctly documented. The nature of the hazard
must be defined by the customer and a survey carried out to
determine the proximity of the safe area to establish cable
runs.

The probability of a flammable mixture being present is


defined by a zone number. Flammable gasses are classified
in Groups and their minimum spontaneous ignition
temperature is categorised by Class. Tyco Fire Protection
Products supplied equipment marked EEx ia IIC T5 would
be suitable for use in worst case conditions. E.G. Zone 0
(ia), Hydrogen (IIc), T5 (100 deg C). The Fire Alarm
Equipment and Safety Barriers should be placed as near as
possible to the containment wall of the Hazardous Area.
This minimises the cable lengths between the barrier and
the Hazardous Area and thus the capacity to store energy.

12/13 Fire Catalogue Chapter 10 Page 7


FIRE_Ch10_Special_Hazards:Layout 1 19/12/2013 16:20 Page 8

Chapter 10 - Special Hazards


801PHEx/811PHExn Smoke and Heat Detector
The 801PHEx/811PHExn Optical or Low) combined with heat fixed Storage Temp:
Smoke & Heat Detectors form part of temperature 60°C (A2S) -40°C to +70°C
the 800Ex Series of MX Addressable • HPO (sensitivity - High, Normal or Relative Humidity:
Fire Detectors. The detector plugs Low) combined with heat fixed 95% non- condensing
into the 5BEX base. temperature 60°C (A2S)
Product Codes
Technical Specification 516.800.530
The mode of detector may be:
• Optical smoke only detector ATEX Code: 801PHEx Optical Smoke + Heat
(sensitivity - High, Normal or Low) Ex ia EX II 1GD Detector
• HPO smoke detector (sensitivity - Exn EX II 3G 516.800.534
High, Normal or Low) Cenelec Code: 811PHExn Marine Optical Smoke +
• Heat only rate-of-rise (A1R) Ex ia IIC T5/Ex iaD 20 T100°C/ Heat Detector
detector (no sensitivity selection) EExnA II T4 Manual Vol 17A-02-PHExn
• Heat fixed temperature 60°C (A2S Weight: 17A-02-PHEx
no sensitivity selection) 0.2Kg detector and base (approx)
• Optical (sensitivity - High, Normal Operating Temp. Range:
-25°C to +70°C

801CHEx/811CHExn CO & Heat Detector

The 801CHEx/811CHExn Carbon Technical Specification Product Codes


Monoxide plus Heat Detector form ATEX Code: 516.800.531
part of the 800Ex Series of MX Ex ia EX II 1GD 801CHEx Carbon Monoxide + Heat
Addressable Fire Detectors. The Exn EX II 3G Detector
detector plugs into the 5BEX base. Cenelec Code: 516.800.535
Ex ia IIC T5/Ex iaD 20 T100°C/ 811CHExn Marine Carbon Monoxide
The mode of detector may be: EExnA II T4 + Heat Detector
• Heat only detector (A1R or A2S) Weight:
(sensitivity: - High, Normal or Low) 0.2Kg detector and base (approx) Manual Vol 17A-02-CHExn
• Compensated Carbon Monoxide Operating Temp. Range: 17A-02-CHEx
detector (sensitivity: - High, Normal 0°C to +55°C/-20°C to +40°C
or Low) Storage Temp:
• Compensated Carbon Monoxide -20°C to +55°C
detector (sensitivity: - High or
Relative Humidity:
Normal) combined with heat (A1R)
95% non condensing

801HEx/811HExn Heat Detector


The 801HEx/811HExn Heat Technical Specification Product Codes
Detectors form part of the 800Ex ATEX Code: 516.800.532
Series of MX Addressable Fire Ex ia EX II 1GD 801HEx Heat Detector
Detectors. The detector plugs into Exn EX II 3G 516.800.536
the 5BEX base. Cenelec Code: 811HExn Marine Heat Detector
Ex ia IIC T5/Ex iaD 20 T100°C/
The mode of detector may be: EExnA II T4 Manual Vol 17A-02-HExn
• EN54-5 A1R, rate-of- rise normal Weight: 17A-02-HEx
ambient 0.2Kg detector and base (approx)
• EN54-5 A2S, fixed 60°C Operating Temp. Range:
• EN54-5 CR, rate-of-rise high -25°C to +70°C
ambient Storage Temp:
-40°C to +70°C/-40°C to +80°C
Relative Humidity:
95% non-condensing

801FEx Flame Detector

The 801FEx point type flame Technical Specification Product Codes


detector forms part of the MX ATEX Code: Ex II 1GD 516.800.066
Technology®range of digital Cenelec Code: Ex ia IIC T4/ 801FEx I.R. Flame Detector
addressable fire detectors. The Ex iaD 20 T135°C 516.800.067
detector plugs into the 5BEX base. Weight: 811FEx Marine I.R. Flame Detector
0.2Kg detector and base (approx)
The 801FEx is a full featured solar Operating Temp.Range: Manual Vol 17A-02-FEX
blind flame detector and can detect -20°C to +70°C
a 0.1m2 fire at a range of 20m. Storage Temp:
-40°C to +80°C
Relative Humidity:
90% non-condensing

Chapter 10 Page 8 Fire Catalogue 12/13


FIRE_Ch10_Special_Hazards:Layout 1 19/12/2013 16:20 Page 9

Chapter 10 - Special Hazards


IS28 Mark 5 Banshee Electronic Sounder

The IS28 Mark 5 Banshee Electronic Please Note:- Technical Specification


Sounder is the industry standard 1.The IS28 Mark 5 Banshee • Intrinsically Safe for use in
intrinsically safe sounder for use in Electronic Sounder must only be hazardous gas and dust
hazardous gas and dust used with the MTL5525 Sounder environments
environments. This traditional high Driver (517.001.304) and not be • ATEX Approved: Ex II 1GD
profile Banshee Electronic Sounder connected to any other type of (Certificate Number
has 32 tones providing ultimate Sounder Driver (barrier) new or ITS10ATEX27151X)
flexibility and is designed to be existing on the system.
• IECEX Approved: Certificate
connected directly to the 24Vdc
Number IECEX ITS 10.0050X
sounder circuit of an addressable 2.Nothing else must be connected to
Fire Alarm Control Panel via an the MTL5525 except IS28 Mark 5 • Gas Code: Ex ia IIC T5
MTL5525 Safety Barrier. Banshee Electronic Sounders • Dust Code: Ex ia IIIC T100oC
(maximum of 3 per barrier, • Ingress Protection to IP66
irrespective of the selected tone). • Choice of 32 Selectable Tones
• Choice of 3 Volume Settings
• 2 x 20mm Cable Entry Knockouts

Product Code
576.501.017
IS28 Mark 5 Banshee Sounder

CP840Ex Break Glass Call Point


The CP840Ex Weatherproof Break Technical Specification Product Code
Glass Call Point is designed to ATEX Code: Ex II 1GD
514.800.513
monitor and signal the condition of a Cenelec Code: Ex ia IIC T5/Ex iaD
switch contact associated with the 20 T100°C CP840Ex MX Digital Addressable
break glass. Operating Temp Range: Break Glass Call Point
-25°C to +70°C
Storage Temp: -30°C to +70°C Manual Vol 17A-02-CPEx
Relative Humidity: Up to 95% RH
non condensing

CP830Exn Break Glass Call Point


The CP830Exn Weatherproof Break Technical Specification Product Code
Glass Call Point is designed to ATEX Code: Ex II 3G 514.800.514
monitor and signal the condition of a Cenelec Code: EEx nL IIC T4
CP830Exn Marine MX Digital
switch contact associated with the (-20oc ≤ Ta ≤
Addressable Break Glass Call Point
break glass. +40oc)
Operating Temp Range:
-25°C to +70°C Manual Vol 17A-02-CP830Exn
Storage Temp: -40°C to +80°C
Relative Humidity:
Up to 95% RH
non condensing

IF800Ex Interface Module

The Intrinsically Safe IF800EX Technical Specification Product Code


Interface Module is designed to ATEX Code: Ex II 1GD 514.001.062
monitor fire contacts such as Cenelec Code: EEx ia IIC T5
IF800Ex MX Digital Addressable
sprinkler flow switches. The IF800Ex Interface Module Assembly
is contained within a grey
compression moulded glass filled Manual Vol 17A-02-IFEX
polyester box with 2 x 20mm cable
gland holes.

The electronic components are


mounted on a double sided printed
circuit board built into a potted
module formed from a plastic
moulding. Connectivity is via two
terminal blocks fitted to the PCB.

12/13 Fire Catalogue Chapter 10 Page 9


FIRE_Ch10_Special_Hazards:Layout 1 19/12/2013 16:20 Page 10

Chapter 10 - Special Hazards


EXI800 Interface Module & Galvanic Isolators
The EXI800 Interface Module when The IS loop output of the EXI800 Product Codes
used with a galvanic isolator, provides interfaces with the Pepperl & Fuchs 514.001.063
a path for an MX panel to KFDO-CS-Ex1.54 Galvanic Isolator EXI800 Interface Module
transparently communicate to slave supplying loop voltage and signalling 517.001.306
devices (800Ex Detectors, IF800Ex currents to the Intrinsically Safe Loop. Pepperl & Fuchs KFDO-CS-
Interface Module or CP840Ex The EXI800 is supplied complete with EX1.54 Galvanic Isolator
Addressable Break Glass Call Point) a service tool EX dongle that is 517.001.304
connected to the Intrinsically Safe required to activate the address MTL5525 I.S. Sounder Driver
Loop. The EXI800 interface reduces programming when using the
the standard MX loop supply voltage standard MX service tool. The
and signalling currents to levels that MTL5525 Isolating Sounder Driver Manual Vol 17A-02-EXI
are acceptable for hazardous areas. enables an intrinsically safe sounder
The EXI800 can detect a short circuit located in the hazardous area, to be
on the left-loop, the right-loop, or the controlled from the safe area. The
IS spur and will isolate the offending MTL5525 has one channel and is
circuit from the other loop suitable for connecting certified loads
connections. in Zone 0, IIC, T4-T6 hazardous
areas.

IS Barrier Enclosure
The MTL ’DX’ Series enclosures will Product Codes
house the EXI800 (20mm pitch), 517.001.248
Pepperl & Fuchs KFDO-CS-Ex1.54 DX070 Enclosure
Galvanic Isolator (20mm pitch) and 517.001.247
the MTL5525 I.S. Sounder Driver DX170 Enclosure
(16.2mm pitch). The units are DIN
rail mounted with 70mm of rail
supplied with the DX070 and 170mm
of rail with the DX170. The
enclosures are usually selected on
the number of units they will
accommodate. The following table
shows the capacity of each of the
enclosure types.

Enclosure MTL5500 isolators 16.2mm Pitch MTL7700 barriers 7.5mm Pitch

DX070 4 (2*) 9 (5*)


DX170 10 (8*) 22 (18*)
* Use these figures when two IMB57 mounting brackets for tagging/earth rail accessories are included.

Chapter 10 Page 10 Fire Catalogue 12/13


FIRE_Ch10_Special_Hazards:Layout 1 19/12/2013 16:20 Page 11

Chapter 10 - Special Hazards


Features
• Glass Reinforced Polyester Enclosure – light, strong and
not subject to corrosion.
• Resettable Element.
• Explosion protected EExe (ATEX Approved).
• In line and end of line resistors.
• Red Epoxy Finish.
• 7 x terminals.
• Lift flap for extra protection against inadvertent operation.
• 1 x changeover switch.
• Captive cover screws.
• Key operated test facility – simple but secure.
• 1 x M20 bottom cable entry.

BG MIM800 Callpoint EX II 2 GD
An Ex II 2 GD Dust Approved & Increased Safety (EExemd)
Resettable Manual Alarm Call Point for use with the EExd
Flameproof MIM800 input module in EExd housing on an
Addressable Detection & Releasing System in gas and dust
explosive risks.

Please note that the above part is only compatible with


Consys Version 17.0 and above when used with
577.800.067.
Technical Specification Product Code
Protection: Explosion Protected 514.001.107 EX II 2 GD Dust Approved & Increased
EExed(Increased Safety) Safety (EExemd) Resettable Manual
Certification: ATEX approved Ex II 2 GD Alarm Callpoint
BAS02ATEX2105X
EExemdIICT4
CENELEC EN50014
EN50019
EN50018
EN50028
Suitable for use in Zones 1 & 2
Voltage: Up to 250V
Certified Temperature: -20oC to +50oC
Ingress Protection: IP66 & 67
Terminals: 7 x 2.5mm²
Switch Ratings(1 x Changeover):
DC 0-30V 5A (Resistive) or 3A
(Inductive)
DC 30-50V 1A Resistive or Inductive
AC 0-254V 5A Resistive or Inductive
Cable Entries: 1 x M20 Bottom
Weight: 1.2Kg
Material: Anti Static U.V. Resistant Glass
Reinforced Polyester
Finish: Red Epoxy Paint
Resistors: Alarm: 100 Ohm
EOL: 250 Ohm
Labelling: Burning House Symbol
Dimensions (W X H X D):
120mm x 126mm x 75mm

12/13 Fire Catalogue Chapter 10 Page 11


FIRE_Ch10_Special_Hazards:Layout 1 19/12/2013 16:20 Page 12

Chapter 10 - Special Hazards


Features
• Copper Free Metal Alloy Aluminium Housing
• Explosion Protected to EExd (ATEX Approved)
• 9 x Terminals
• 3 x M20 Cable Entries
• Fast Interrupt Mode for Call Points

MIM800 Input Module in EExd Housing


An EExd Flameproof MIM800 Addressable Module for
extending the monitoring of Call Points and other Alarm
Inputs on an MX, ZX and MZX Addressable System in gas
and dust explosive risks.

Please note that the above part is only compatible with


Consys Version 17.0 and above when used with
514.001.107.

Technical Specification Product Code


Protection: Explosion Protected EExd 577.800.067 MIM800 Input Module in EExd Housing
(Flameproof)
Certification: Ex II 2 GD LOM02ATEX2037
EExdIICT6
CENELEC EN50014
EN50018
EN50019
EN50281-1-1
EN60439-1
Suitable for use in Zones 1 and 2
to IEC 60079-10
Suitable for use in Zones 21 and 22
to EN50281-3
Voltage: 40Vdc
Certified Temperature: -20oC to +55oC
Ingress Protection: IP67
Terminals: 9 x 2.5mm²
Cable Entries: 3 x M20 (No Blanking Plugs)
Weight: 0.8 Kg
Material: Metal Alloy Aluminium - Copper
Free
Dimensions
(W X H X D): 108mm x 98mm x 90mm

Chapter 10 Page 12 Fire Catalogue 12/13


FIRE_Ch10_Special_Hazards:Layout 1 19/12/2013 16:20 Page 13

Chapter 10 - Special Hazards


Features
• Allows the DDM800 to be mounted in a Hazardous Area.
• Allows the monitoring of Call Points and other Alarm
Inputs (including 4-20mA devices) designed for use in
Hazardous Areas on an MX, ZX and MZX Addressable
System in gas and dust explosive risks.
• Approved for use in Gas Zone 1 and 2.
• Approved for use in Dust Zone 21 and 22.
• Copper Free Metal Alloy Aluminium Housing.
• Explosion Protected to EExd (ATEX Approved).
• 5 x M20 Cable Entries (3 x bottom and one each side).

DDM800 Fire & Gas Detector Module in EExd Housing


A DDM800 Fire and Gas Detector Module in a EExd The DDM800 is supported by MXConsys® Version 15 and
Housing for use in special hazardous area applications. above and Issue 6 MXDesigner. It is recommended that
MXDesigner is used for all system designs using DDM800
The DDM800 Universal Fire and Gas Detection Module is a modules. For detailed design and application details,
detector module designed to interface a wide range of please refer to document "DDM800 Universal Fire & Gas
conventional fire detectors to MZX Technology® control Detector Module Product Application and Design
panels. Information" reference 17A-02-DDM.

Additionally the option is available to connect two 4 to


20mA devices and to configure the alarm thresholds within
the control panel.

Technical Specification Product Code


Protection: Explosion Protected EExd 577.800.066 DDM800 Fire & Gas Detector Module in
(Flameproof) EExd Housing
Certification: Ex II 2 GD LOM02ATEX2037
EExdIICT6
CENELEC EN50014
EN50018
EN50019
EN50281-1-1
EN60439-1
Suitable for use in Zones 1 and 2 to
IEC 60079-10
Suitable for use in Zones 21 and 22
to EN50281-3
Voltage: 40Vdc
Certified Temperature: -20oC to +55oC
Ingress Protection: IP67
Terminals: 12 x 2.5mm²
Cable Entries: 5 x M20 (3 Blanking Plugs Supplied)
Weight: 1.3 Kg
Material: Metal Alloy Aluminium - Copper Free
Dimensions
(W X H X D): 150mm x 150mm x 104mm

12/13 Fire Catalogue Chapter 10 Page 13


FIRE_Ch10_Special_Hazards:Layout 1 19/12/2013 16:20 Page 14

Chapter 10 - Special Hazards


Features
• Allows the SIO800 to be mounted in a Hazardous Area.
• Allows the status of a normally open contact to be
monitored and/or a volt free change over relay output in
a Hazardous Area to be interfaced onto an MX, ZX and
MZX Addressable System in a gas and dust explosive
risk.
• Approved for use in Gas Zone 1 and 2.
• Approved for use in Dust Zone 21 and 22.
• Copper Free Metal Alloy Aluminium Housing.
• Explosion Protected to EExd (ATEX Approved).
• 5 x M20 Cable Entries (3 x bottom fitted with blanking
plugs and one each side supplied open).

SIO800 I/O Module in EExd Housing


The SIO800 Single Input/Output Module is designed to
monitor a normally open contact input and provide a volt
free changeover relay output. This enables inputs and out-
puts from hazardous area devices to be easily interfaced to
the MX, MZX, MX2, T2000 and ZX Range of Control Panels.

Technical Specification Product Code


Protection: Explosion Protected EExd 555.800.072 SIO800 Single Input/Output Module in
(Flameproof) EExd Housing
Certification: Ex II 2 GD KEMA 09ATEX0110
EExdIICT6
CENELEC EN50014
EN50018
EN50019
EN50281-1-1
EN60439-1
Suitable for use in Zones 1 and 2 to
IEC 60079-10
Suitable for use in Zones 21 and 22
to EN50281-3
Voltage: 40Vdc
Certified Temperature: -20oC to +55oC
Ingress Protection: IP67
Terminals: 9 x 2.5mm²
Cable Entries: 5 x M20
Weight: 1.64 Kg
Material: Metal Alloy Aluminium - Copper
Free
Dimensions
(W X H X D): 150mm x 150mm x 104mm

Chapter 10 Page 14 Fire Catalogue 12/13


FIRE_Ch10_Special_Hazards:Layout 1 19/12/2013 16:20 Page 15

Chapter 10 - Special Hazards

System 620 Fire Detection for Hazardous Areas


Features
• Conventional I.S. system
• Suitable for worst case (EEx ia IIC T5)
• High Performance Optical (HPO) smoke detector
• Compatible with S231i+ flame detector
• Compatible I.S. callpoint
• Suitable for use in Zone 0,1,2,20,21& 22

System 620 Fire Detection


A complete range of ATEX and ICEX certified detectors The number of devices connected to the barrier and located
suitable for use in Zones 0,1,2,20,21 & 22 areas for use on in the Hazardous Area must always be limited to not more
conventional panels. There is a risk of fire or explosion in all than the listed maximum.
areas containing flammable substances in the form of
liquids, gasses, dust or materials. Where these combustible When a mixture of devices is connected to any one zone the
materials are mixed with air in sufficient concentration they numbers must be reduced in proportion to the ratio of the
form a flammable atmosphere and the areas containing load presented to the barrier. When a System includes the
them are designated Hazardous Areas. When a source of use of an S231i+, it must be remembered that the load it
ignition, such as a spark, is applied in a hazardous area, an presents to the circuit is twice that of a detector. A mixture of
explosion could take place. Electrical equipment supplied large and small load devices connected to a zone will
for use in Hazardous Areas must comply with requirements require a calculation for the number of allowed detectors.
to ensure that its introduction into the area does not
increase the existing risk. System 620 is an Intrinsically Safe System 620
(I.S.) system for use in Hazardous Areas which can be System 620 is for use in conventional fire detection circuits.
connected to a conventional fire Alarm Controller installed in Two Sounder Systems, (one earthed and one isolated), are
the Safe Area. available and either can be used with System 620.

The System Designer must be familiar with ATEX Datasheet - PSF122U


certification and have successfully completed an
appropriate recognised course in Intrinsic Safety. Design
of the system requires that the designer has all the
information concerning the installation correctly
documented. The nature of the hazard must be defined by
the customer and a survey carried out to determine the
proximity of the safe area to establish cable runs.

The probability of a flammable mixture being present is


defined by a Zone Number. Flammable gases are classified
in Groups and their minimum spontaneous ignition
temperature is categorised by Class. Tyco Fire Protection
Products supplied equipment marked EEx ia IIC T5 would
be suitable for use in worst case conditions. Eg. Zone 0 (ia),
Hydrogen (IIc), T5 (100 deg C). The Fire Alarm Equipment
and Safety Barriers should be placed as near as possible to
the containment wall of the Hazardous Area. This minimises
the cable lengths between the barrier and the Hazardous
Area and thus the capacity to store energy.

In order that an Installation will comply with the ATEX


certification designated for each system it is essential that
the certified devices are connected with cables of the
specified limits. These limits have been certified for specific
classifications of hazard in order that energy storage is
limited.

12/13 Fire Catalogue Chapter 10 Page 15


FIRE_Ch10_Special_Hazards:Layout 1 19/12/2013 16:20 Page 16

Chapter 10 - Special Hazards


High Performance Optical Smoke

The MR601TEX has been developed burning liquids which do not Product Code
to overcome the slower response of generate smoke particles. 516.054.011.Y (Vol 01B-04-D12)
the optical detectors to hot burning
MR601TEX Conventional High
fires, by increasing the sensitivity of
ATEX Code: Ex II 1GD Performance Optical Smoke Detector
the optical detector when it is
Cenelec Code: Ex ia IIC T5/
associated with a rapid change in
Ex iaD 20
temperature. In this way it is intended
T100°C
to become a detector which can
Operating Temp Range:
cover some of the risks currently
-20°C to +70°C
covered by ion chamber detectors.
Storage Temp: -25°C to +80°C
Smoke detectors will not detect
Relative Humidity: 95% non-
burning alcohol or other clean
condensing

Heat Detectors
If environmental conditions rule out er rooms, sudden, large changes in Product Codes
the use of smoke detectors, then a temperature are considered 'normal'. 516.052.051.Y (Vol 01B-04-D11)
heat detector of the type Rate-of-rise detectors are generally
MD601EX Conventional Rate of Rise
MD601Ex/MD611Ex may provide an not suitable in these cases and fixed
Heat Detector
acceptable, though less sensitive, temperature [static] types should be
alternative. For general use, and par- 516.052.041.Y (Vol 01B-04-D11)
used.
ticularly where the ambient tempera- MD611EX Conventional Fixed
ture may be low, a 'Rate-of-Rise' heat ATEX Code : Ex II 1GD Temperature Heat Detector
sensor is to be preferred. This type of Cenelec Code: Ex ia IIC T5/
sensor reacts to abnormally high Ex iaD 20
rates of change of temperature and T100°C
provides the fastest response over a Operating Temp Range:
wide range of ambient temperatures. -20°C to +70°C
A fixed temperature limit is also incor- Storage Temp: -25°C to +80°C
porated in these detectors. In many Relative Humidity: 95% non-
environments, e.g. kitchens and boil- condensing

Flame Detectors

Flame detectors, unlike smoke and clean-burning fuels such as alcohol ATEX Code: Ex II 1GD
heat detectors, do not rely on or methane, i.e. fires which would not Cenelec Code: Ex ia IIC T4/
convection to transport the fire be detected by smoke detectors. The Ex iaD 20
products to the detector nor do they 601FEx Flame Sensor, by virtue of its T135°C
rely on a ceiling to trap the products. operating wavelength and flicker Operating Temp Range:
They can therefore be used to discrimination is insensitive to normal -20°C to +70°C
protect large open areas without environmental influences. For Storage Temp: -40°C to +80°C
sacrificing speed of response to outdoor use a solar-blind detector Relative Humidity: 90% non-
flaming fires. In order to ensure full [e.g. the S200 Plus] should be used. condensing
coverage however, flame detectors The 601FEx Flame detector should,
Product Codes
do require direct line of sight to all normally, only be used inside
parts of the protected area. buildings to supplement heat and 516.600.066 (Vol 01C-02-D10)
smoke detectors. 601FEx Infra-Red Flame Detector
Infra-red flame detectors such as the
601FEx are designed to respond 516.600.067 (Vol 01C-02-D10)
rapidly to fires which involve 601FEx-M Infra-Red Flame Detector
(Marine)

Enhanced Carbon Monoxide Fire & Heat Detector

The MDU601EX detector is a Cenelec Code: Ex ia IIC T5/ Product Code


combined CO and Rate of Rise Heat Ex iaD 20 516.061.001.Y (Vol 01B-04-D14)
Detector where the sensitivity of the T100°C MDU 601EX Enhanced Carbon
CO detector is enhanced in response Operating Temp Range: Monoxide Fire & Heat Detector
to a fast rate of change of
-10°C to +55°C
temperature.
Storage Temp: -20°C to +55°C
ATEX Code: Ex II 1GD
Relative Humidity: 90% non-
condensing

5BEX Detector Base and Ancillaries

ATEX Code: Ex II 1GD Product Codes


Cenelec Code: Ex ia IIC T5/ 517.050.023
Ex iaD 20 5BEX 5” Universal Ex Base
T100°C 517.050.603
Operating Temp Range: DHM-5B deckhead mounting
-25°C to +70°C 517.001.120
Storage Temp: -40°C to +80°C System 601 EOL Unit (Pk 10)
Relative Humidity: 95% non-
condensing

Chapter 10 Page 16 Fire Catalogue 12/13


FIRE_Ch10_Special_Hazards:Layout 1 19/12/2013 16:20 Page 17

Chapter 10 - Special Hazards


Features
• Intrinsically Safe
• Weatherproof to IP67
• Compatible with System 620

Intrinsically Safe Callpoint - ATEX Approved


The MCP220Ex is a conventional callpoint for use on the
ATEX Certified System.

Technical Specification Product Code


Dimensions: 93H x 98W x 66Dmm 514.001.109 MCP220Ex Red Callpoint intrinsically safe
Weight: 270g for use with ATEX certified conventional
Material: PC/ABS system 620.
Colour: Red
ATEX Code: Ex II 1GD
Cenelec Code: EX ia IIC T4 Ga
/EX iaD T135°c Da
ATEX Cert: SIRA 06ATEX2131X
IP Rating: IP67

Features
• Intrinsically safe
• Weatherproof to IP66/IP67
• Robust GRP Housing

BG3 Intrinsically Safe Conventional Callpoint -Atex Approved


This manual fire alarm call point is designed in accordance Units are supplied in self coloured GRP with a ‘Burning
with the latest European Callpoint Standard (EN54-11). House’ duty label as standard.

Weatherproof to IP66/IP67 and available certified


intrinsically safe, simple apparatus manufactured from
glass reinforced polyester (GRP) which provides a robust,
corrosion free construction and ensures effective and
reliable operation in harsh industrial and offshore
environments.

Technical Specification European Standard


Model: BG3I for Callpoints: EN54-11
Protection: Explosion Protected EExia Terminals: 6 X 4.0mm2
(Intrinsically Safe) Cable Entries: 2 X M20 Bottom
Certification: CENELEC EN50014, 020 Weight: 0.5Kg
BASEEFA EExia IIC T4 Material: UV resistant glass reinforced polyester
Cert No. BAS00ATEX1067X Finish: Natural Red GRP
Suitable for use in Zones 0,1 & 2
Voltage: Up to 28V (IS)
Certified Temp: -55°C to +55°C
Product Code
Ingress Protection: IP66 & IP67 514.001.059 Intrinsically Safe Callpoint (BG3I4NBN)

12/13 Fire Catalogue Chapter 10 Page 17


FIRE_Ch10_Special_Hazards:Layout 1 19/12/2013 16:20 Page 18

Chapter 10 - Special Hazards


Features
• Polyester Enclosure – light, strong and not subject to
corrosion.
• Break Glass.
• Explosion protected EExe (ATEX Approved).
• In line and end of line resistors.
• Red.
• 9 x terminals.
• Lift flap for extra protection against inadvertent operation.
• 1 x changeover switch.
• Captive cover screws.
• No hammer required – the glass is covered by a
membrane thus protecting the operator from glass
fragments.
• Key operated test facility – simple but secure.
• 2 x M20 bottom cable entries.

BG Conventional Callpoint EX II 2 GD
This EX II 2 GD Dust Approved & Increased Safety It is also fitted with a removable link which allows it to be
(EExemd) Conventional Break Glass Manual Alarm Call connected on its own or with other Conventional Devices to
Point is fitted with a 470 ohm Alarm Level Resistor and a a Tyco Conventional Detection Circuit.
4K7 ohm EOL Resistor for use with Tyco Conventional
Detection Circuits including the DIM800 and DDM800 MX
Modules.

Technical Specification Product Code


Protection: Explosion Protected EExed 514.001.108 EX II 2 GD Dust Approved & Increased
(Increased Safety) Safety (EExemd) Conventional Break
Certification: ATEX approved Ex II 2 GD Glass Manual Alarm Callpoint
BAS02ATEX2105X
EExedmIICT4
CENELEC EN50014
EN50019
EN50018
EN50028
Suitable for use in Zones 1 & 2
Voltage: Up to 250V
Certified Temperature: -20oC to +50oC
Ingress Protection: IP66 & 67
Terminals: 9 x 2.5mm – up to 60V
Switch Ratings(1 x Changeover):
DC 0-30V 5A (Resistive) or 3A
(Inductive)
30-50 1A Resistive or Inductive
AC 0-254V 5A Resistive or
Inductive
Cable Entries: 2 x M20 Bottom
Weight: 1.2Kg
Material: Anti Static U.V. Resistant Glass
Reinforced Polyester
Finish: Red Epoxy Paint
Resistors: Alarm: 470 Ohm
EOL: 4K7 Ohm
Labelling: Burning House Symbol

Chapter 10 Page 18 Fire Catalogue 12/13


FIRE_Ch10_Special_Hazards:Layout 1 19/12/2013 16:20 Page 19

Chapter 10 - Special Hazards

IS28 Mark 5 Banshee Electronic Sounder


The IS28 Mark 5 Banshee Electronic Sounder is the Please Note:-
industry standard intrinsically safe sounder for use in 1.The IS28 Mark 5 Banshee Electronic Sounder must only
hazardous gas and dust environments. This traditional high be used with the MTL5525 Sounder Driver (517.001.304)
profile Banshee Electronic Sounder has 32 tones providing and not be connected to any other type of Sounder Driver
ultimate flexibility and is designed to be connected directly (barrier) new or existing on the system.
to the 24Vdc sounder circuit of a conventional Fire Alarm
Control Panel via an MTL5525 Safety Barrier. 2.Nothing else must be connected to the MTL5525 except
IS28 Mark 5 Banshee Electronic Sounders (maximum of 3
per barrier, irrespective of the selected tone).

Technical Specification Product Code


• Intrinsically Safe for use in hazardous gas and dust 576.501.017 IS28 Mark 5 Banshee Sounder
environments
• ATEX Approved: Ex II 1GD (Certificate Number
ITS10ATEX27151X)
• IECEX Approved: Certificate Number IECEX ITS
10.0050X
• Gas Code: Ex ia IIC T5
• Dust Code: Ex ia IIIC T100oC
• Ingress Protection to IP66
• Choice of 32 Selectable Tones
• Choice of 3 Volume Settings
• 2 x 20mm Cable Entry Knockouts

12/13 Fire Catalogue Chapter 10 Page 19


FIRE_Ch10_Special_Hazards:Layout 1 19/12/2013 16:20 Page 20

Chapter 10 - Special Hazards


Features
• Robust GRP Body
• Suitable for offshore and petrochem
• Certificated Intrinsically Safe

XB8 Intrinsically Safe Beacon


This ruggedised, intrinsically safe and weatherproof Please refer to MEDC for guidance on cable capacitance
beacon is intended for use in potentially explosive and barriers.
atmospheres, and has been designed with high ingress
protection to cope with the harsh environmental conditions
found offshore and onshore in the oil, gas and
petrochemical industries.

Technical Specification Product Code


Certification: CENELEC EN50014, 20 & 39 540.001.038 Intrinsically Safe Xenon Beacon
BAS02ATEX1258X (XB8BB024CNR)
EExia IIB T4
Zones 0,1 & 2
Material: UV stable glass reinforced
polyester body. Clear
polycarbonate cover/lens.
Retained stainless steel cover
screws.
Finish: Painted Red
Tube Type: Xenon discharge
Lens Colour: Clear
Terminals: 8 x 2.5mm2
Flash Rate: 1 flash per second
Cable Entries: Up to 3 x M20 via knockouts
Tube Energy: 0.5 Joules
Weight: 1.4kg
Certified Temperature: -55°C to + 60°C
Ingress Protection: IP66 & IP67
Tube Life: >1 x 106 Flashes
Voltage: 24V via suitable barrier
Current Consumption: 71mA max nominal

Chapter 10 Page 20 Fire Catalogue 12/13


FIRE_Ch10_Special_Hazards:Layout 1 19/12/2013 16:20 Page 21

Chapter 10 - Special Hazards


Features
• For use in hazardous areas
• Robust GRP construction
• Powerful Output, up to 118dBA

DB3 Flameproof Horn Sounder


This lightweight all GRP flameproof sounder is intended for The flamepaths, flare and body, are manufactured
use in potentially explosive gas and dust atmospheres and completely from a UV stable glass reinforced polyester.
has been designed with high ingress protection to cope Stainless steel screws and sinter are incorporated thus
with the harsh environmental conditions found offshore and ensuring a corrosion free product. A tapered flamepath is
onshore in the oil, gas and petrochemical industries. used to overcome the problems of assembly of parallel
spigot flamepaths.

Technical Specification
Terminals: 6 x 2.5mm2 *Output measured with 24VDC input voltage. Tone set to
Mounting: Stainless steel bracket with ratchet 970Hz continuous.
facility
Cable Entries: 2 x 20mm EExd. Weight: 6.0kg approx
Tone Selection: 27 user selectable tones. Ingress Protection: IP66 / IP67
Certification: CENELEC EN50014,18,19 Voltage: 12VDC to 48VDC
BASEEFA Cert. No. Certified Temperature: -20o C to +70o C
BAS00ATEX2097X, EExd IIC.
Zones 1 and 2.
Material: Body & horn in anti-static, UV
stable, glass reinforced polyester.
Swivel bracket & captive cover
screws in stainless steel.

Nominal Output (dBA) Input Current (mA)*


93 50
105 100
108 150
111 200 Product Code
112 250 576.501.049 Flameproof Horn Sounder
114 300 (DB3D048N2BNR)
115 350
118 380

12/13 Fire Catalogue Chapter 10 Page 21


FIRE_Ch10_Special_Hazards:Layout 1 19/12/2013 16:20 Page 22

Chapter 10 - Special Hazards


Features
• Robust Corrosion Resistant GRP body
• High Power (5 Joule)
• Certificated Flameproof

XB11 Flameproof Xenon Beacon


These certified beacons have been designed for use in The beacon housing is manufactured completely from a
potentially explosive gas and dust atmospheres and harsh U.V. stable, glass reinforced polyester. Stainless steel
environmental conditions. The glass reinforced polyester screws and mounting bracket are incorporated ensuring a
enclosures are suitable for use offshore or onshore, where totally corrosion free product.
light weight combined with corrosion resistance is required.

Technical Specification Product Code


Voltage: 24Vdc 540.001.039 Flameproof Xenon Beacon
Tube Energy: 5 Joules (XB11B02406RNBNNNR)
Peak Current
Consumption (mA): 320
Effective Intensity (Cd): 29
Peak Intensity (Cd): 22213
Power Consumption
(Watts): 8
Note: The Cd figures are for a clear
lens @ 1Hz flash rate. For red
lens multiple by 0.15
Weight: 2.5Kg
Certified Temperature: EExd -55°C to + 70°C (T4)
-55°C to + 55°C (T5)
-55°C to + 40°C (T6)
Ingress Protection: IP66 & IP67
Terminals: 6 x 2.5mm2
Entries: 2 x 20mm ISO EExd.

Certification: BASEEFA EExd IIB


135°C (-55 to AMB +70°C)T4
100°C (-55 to AMB + 55°C)T5
85°C (-55 to AMB + 40°C)T6
Cert. No. 99 ATEX 2195X.
CENELEC EN50014 and
EN50018
Material
Body: Glass reinforced polyester
Lens: Glass
Cover Screws + Backstrap:
Stainless steel 316
Finish: Red

Chapter 10 Page 22 Fire Catalogue 12/13


FIRE_Ch10_Special_Hazards:Layout 1 19/12/2013 16:20 Page 23

Chapter 10 - Special Hazards

Intrinsically Safe Barriers - Atex Approved


The following section relates to a range of intrinsically safe barrier and isolator equipment for use with Tyco Fire
Protection Products manufactured fire detection systems. It essentially encompasses the relevant MTL5500 and
MTL7700 series barriers plus the associated housing options as an alternative to existing MTL700 series equipment.

On all issues of intrinsically safe system design, please refer to Manual 26A for guidance.

Galvanic Isolators - MTL5500

The MTL5561 is a two channel The MTL5525 Isolating Sounder When designing new systems or
interface for use with conventional Driver enables an intrinsically safe upgrading existing MTL3000 series
detectors located in hazardous areas. sounder located in the hazardous systems to MTL5500 series, please
This galvanic isolator is CE marked, area, to be controlled from the safe use the appropriate MTL “DX” series
and replaces the MTL3043 barrier area. The MTL5525 barrier is enclosure equipment (16.2mm
option. It is suitable for connecting designed as a CE marked pitch).
loads in Zone 0, IIC, T4-T6 hazardous replacement for the existing Product Codes
areas if suitably certified. MTL3021 barrier. It has one channel 517.001.302
and is suitable for connecting loads
MTL5561 2 Channel Galvanic Isolator
in Zone 0, IIC, T4-T6 hazardous
517.001.304
areas if suitably certified.
MTL5525 I.S. Sounder Driver

Zener Barriers - MTL7700

The MTL7700 Series intrinsically safe One secondary replaceable fuse for Please note that this barrier is a
shunt-diode safety barriers are each barrier channel is provided and direct alternative for the MTL728+
innovative devices designed to is lower in value than the safety barrier.
provide exceptionally high packing related fuse. Fuses are packaged in
densities, straightforward installation small mouldings which can be
and simplified connection, latched in a disconnect position to Product Code
commissioning and maintenance break the safe and hazardous areas
517.001.301
facilities. The MTL7700 Series during commissioning, maintenance
include secondary replaceable and fault finding, thus avoiding the MTL7728 + Zener Safety Barrier for
fuses. These are useful where there need for additional disconnect conventional detection circuits
is the possibility of faults occurring terminals. designed in accordance with System
during commissioning, which would 601
otherwise blow the barriers’ internal
safety fuses.

Zener Barriers - MTL700

The MTL700 series are 1 or 2 Product Codes


channel devices which pass the 517.001.201
electrical signal from fire detectors to
the control panel or from the control MTL728 Single Channel Zener
panel to the output device. The Safety Barrier
barriers limit the amount of energy 517.001.202
to a level that cannot ignite explosive MTL788 Dual Channel Zener Safety
atmospheres. The over-voltage Barrier
protection provided by a Shunt- 546.004.005
Diode Safety Barrier is with
reference to the safety barrier earth Intrinsically safe sounder circuit
connection. It is therefore imperative interface module
that a HIGH INTEGRITY EARTH is
used for this type of barrier
(14.2mm pitch).

12/13 Fire Catalogue Chapter 10 Page 23


FIRE_Ch10_Special_Hazards:Layout 1 19/12/2013 16:20 Page 24

Chapter 10 - Special Hazards

Safety Enclosures
UC Series Enclosures

The UC series of enclosures Product Code


provides a simple but effective 517.001.196
means of mounting and protecting
UC2 4 Way Barrier Housing
the MTL3000 series units, in safe
areas. A standard lightweight
enclosure with transparent lid, which
can accommodate 4 units. The
polycarbonate enclosure is impact
resistant, flame retardant and
dustproof to IP65.

MT Series Enclosures

The MT series of enclosures Product Codes


provides a simple, effective means 517.001.198
of mounting and protecting MTL700
MT2 2 Way Zener Barrier Housing
Series barriers in safe areas or
low-risk hazardous areas. Three 517.001.199
lightweight polycarbonate enclosures MT5 5 Way Zener Barrier Housing
with see through lids accommodate 517.001.200
up to 2, 5 and 12 barriers in the safe
MT12 12 Way Zener Barrier Housing
area. All the enclosures are supplied
ready fitted with a nickel plated brass
busbar mount, so barriers can be
installed and wired up immediately
without special tools.

Ancillaries
The ERL7 earth rail is a nickel plated Product Codes
3 x 10mm rail (1 metre long), 517.001.205
suitable for a do-it-your self
ERL7 Earth rail for I.S. systems
mounting arrangement. It will
accommodate up to 2.5 ETM7 earth 517.001.206
terminals per barrier location for ETM7 Earth termination connection
terminating earth returns and cable system
screens from the hazardous area. 517.001.207
IMB7 Insulating mounting block
The IMB7 mounts on a flat surface or
top hat rail (35mm) or G-profile rail
and acts as a convenient method for
mounting the earth busbar.

Chapter 10 Page 24 Fire Catalogue 12/13


FIRE_Ch10_Special_Hazards:Layout 1 19/12/2013 16:20 Page 25

Chapter 10 - Special Hazards


Features
• Continuous detection despite extremely large monitoring
area.
• Easy and rapid installation of the maintenance free sensor
cable.
• Very high resistance to extreme ambient influences
(immune against heat, cold, humidity, corrosion, strong
winds and draft).
• Undiminished operation under electromagnetic
interference.
• Unprecedented security against false alarms.
• Very high sensor cable service life of up to 30 years.
• Temperature profile over the complete measurement
range delivers exact information of location, size and
spread of fire.
• Very low maintenance costs as maintenance and trouble
shooting can be done from the control unit.
• VdS certified to EN 54 part 5
• One controller unit will drive up two 8 km spurs or one 8
km loop.
• Easy integration into existing installations.
• Each sensor cable divided into up to 256 zones.
• Individual configuration of 5 alarm criteria per zone.
• Network connection through Modbus, TCP/IP, FTP and
SCPI interfaces.

MZX SensorLaser™ Plus Fibre Optic Linear Heat Detection System


The MZX SensorLaser™ Plus guarantees fast and The MZX SensorLaser™ Plus enables a measuring range of
continuous fire detection even in difficult and varying up to 8 km per sensor cable. Up to 2 spurs each with an 8
ambient conditions. This linear heat detection system km measurement range, or 1 loop with an 8 km range can
enables long and heavily fragmented facilities such as traffic be connected. Since the ambient conditions in a monitoring
and supply tunnels, cable routes and conveyor belts as well area of this size can vary enormously, each sensor cable
as large scale buildings such as production halls, cold can be divided into up to 256 zones. Several alarm criteria
stores and multi storey car parks to be monitored at all can be freely defined in each zone. This level of precision
times. The MZX SensorLaser™ Plus is ideal for use in areas adjustment allows the MZX SensorLaser™ Plus to provide a
that are hard or impossible to access after installation, e.g. high level of resistance to false alarms and precise fire
false floors, since maintenance and troubleshooting can be detection despite contrary and variable ambient conditions.
carried out from the control unit.
The accessible laser radiation emitted by the Class 1M laser
The fibre optic sensor cable itself is maintenance free and, is not hazardous to the eyes (provided there are no other
thanks to its particularly robust characteristics, offers a high optical instruments in the path of the beam), while operation
level of security against false alarms. The sensor cable is is absolutely fail-safe even in the event of a break in the
insensitive to dust, dirt, moisture, high temperatures (up to cable. In addition, the sensor cable can be used in
approx. 90 °C), pressure and the action of vibration and explosive atmospheres (ATEX zones) up to zone 0 without
wind as well as corrosive atmospheres. Because of its any additional measures being required. In contrast to
purely passive, optical analysis process, the MZX conventional fibre optic systems, the low laser output of <
SensorLaser™ Plus is even immune from electromagnetic 20mW ensures that the measuring system has a long
interference caused by generators, energy routes, cables or service life.
electric motors.
Zone Configuration
The MZX SensorLaser™ Plus delivers precise information Ambient conditions (temperatures) can fluctuate sharply
about the location, size and spread of a fire even under over a measuring range of many hundreds of metres. This
ambient conditions that would cause other fire detection makes it essential to divide the measuring range into zones
systems to fail. that can be adapted optimally to the ambient conditions on
the basis of differing alarm criteria. This ensures high
detection reliability and also security against false alarms.

The MZX SensorLaser™ Plus allows the measuring range to


be very finely divided into zones. Up to 256 zones can be
defined for each sensor cable, with up to 5 alarm criteria
configurable in each zone. Another 2 alarm criteria respond
when there is a temperature drop, enabling them to be used
e.g. in tunnels to warn of black ice.

12/13 Fire Catalogue Chapter 10 Page 25


FIRE_Ch10_Special_Hazards:Layout 1 19/12/2013 16:20 Page 26

Chapter 10 - Special Hazards


MZX SensorLaser™ Plus Fibre Optic Linear Heat Detection System Con’t.
Control Unit Plastic Clamps
With ten product variants, permitting measuring ranges of 1 The plastic of these clamps is UV resistant, halogen free
to 8 km, the MZX SensorLaser™ Plus can be configured to and particularly robust in ambient conditions.
suit the particular project.
Steel Clamps
Sensor Cable The clamps in these sets are made of stainless steel or zinc
The sensor cables offered are optimised for a rapid plated steel and are rubber protected. The rubber
response time. The sheathing is flame retardant, halogen protection guarantees that the sensor cable is not damaged
free and resistant to dust, dirt, moisture, corrosive if friction occurs. For every clamp 2 x nuts are included for
atmospheres and most organic solvents. Both types of fixing to the anchor.
sensor cable offer adequate protection against rodents and
are designed for a service life of 30 years. Connection Cable
Connection to the MZX Fire Alarm Panel is by means of the
There are two different types of sensor cable for differing MZX SensorLaser™ Plus Connection Set. This set consists
project requirements. The MZX SensorLaser™ Plus Safety of 3 x cables. For connection of the Fire Alarm Panel to one
cable can be used under normal ambient conditions. It is end of the sensor cable a D-Sub connector is included. The
particularly flexible and extremely versatile. other end of the sensor cable is desoldered which provides
a quick connection into the MZX System without any
Where the sensor cable is expected to be exposed to high soldering effort.
mechanical stresses, we recommend that the MZX
SensorLaser™ Plus Steel Wire Armoured cable be used. Enhanced Communication
This sensor cable, which was specifically developed for The MZX SensorLaser™ Plus iBox allows the 20 relay
heavy duty applications, is particularly suitable where high outputs supplied as standard to be expanded up to 2 x 256
tensile forces and high lateral pressures can occur. outputs so that each zone can be assigned its own relay
output. This could, for instance, be used to control fire
The cable length will be individually cut to the customer extinguishing systems. The iBox also enables connection to
specified length and 2 connectors are fitted for easy SCADA or process control systems via Modbus TCP or
handling. The cable should be commissioned in multiples Modbus RTU.
of one metre and therefore the order for the cable has to be
placed per metre. The number of relays can be extended using the MZX
SensorLaser™ Plus Relay Controller Set. This set consists
Every order for sensor cable must include the of a pre-programmed field bus controller, one Digital Output
corresponding connectors, which will be assembled by the Module and an End module. It also comes with 8 x relays
supplier. The cable with pre assembled connectors offers and accessories for easy wiring.
fast commissioning of the system without any additional
splicing.

Mounting Materials
For professional mounting of the sensor cables four
different types of mounting sets are available. These sets
are designed for different applications. They can be used
for the mounting of the sensor cable to the wall and the
ceiling. Every set contains 100 x clamps, 100 x anchors and
1 x SDS drill bit.

LAN (10/100M)
Modbus / TCP/IP SCPI/FTP Modbus/TCP/IP/SCPI/FPT SCPI

SCADA
System
Controller Unit
Supervisory Control
and Data Acquisition
Interface Box 20 Relay Outputs
1 Fault
PC Work Station 19 Alarms

MZX Panel

Relay Controller
Set Relay Extension
Set
By means of the Relay Controller Set and the Relay Extension Set an
additional 256 relays per sensor cable can be connected.

Chapter 10 Page 26 Fire Catalogue 12/13


FIRE_Ch10_Special_Hazards:Layout 1 19/12/2013 16:20 Page 27

Chapter 10 - Special Hazards


MZX SensorLaser™ Plus Fibre Optic Linear Heat Detection System Con’t.
Complies with the essential requirements of the following SAFETY
applicable European Directives and carries the CE marking IEC61010-1:2001/EN61010-1:2001
accordingly: IEC60825-1:2001/EN60825-1:1994+A11:1996+A2:2001
Canada:CAN/CSA-C22.2No.61010-1:2004
• The Low Voltage Directive 73/23/EEC amended by USA:UL61010-1:2004;FDA21CFR1040.10+Laser Notice
93/68/EEC No.50
• The EMC Directive 2004/108/EC
Conforms with the following product standards:
EMC
IEC61326:1997+A1:1998+A2:2000
EN61326:1997+A1:1998+A2:2001
CISPR11:1997+A1:1999 / EN55011:1998+A1:1999
IEC61000-4-2:2001/EN61000-4-2:1995+A1:1998+A2:2001
IEC61000-4-3:2002/EN61000-4-3:2002
IEC61000-4-4:2001/EN61000-4-4:1995+A1:2001+A2:2001
IEC61000-4-5:2001/EN61000-4-5:1995+A1:2001
IEC61000-4-6:1995+A1:2000 /EN61000-4-6:1996+A1:2001
IEC61000-4-8:2001/EN61000-4-8:1993+A1:2001
IEC61000-4-11:1994+A1:2000
EN61000-4-11:1994+A1:2001
Canada: ICES-001:1998 Product Codes
516.016.310 MZX SensorLaser™ Plus 1/1 – 1 km
Technical Specification range, 1 sensor cable.
516.016.311 MZX SensorLaser™ Plus 1/2 – 1 km
Operating temperature range: range, 2 sensor cables.
-10°C to +60°C (2 channel 516.016.312 MZX SensorLaser™ Plus 2/1 – 2 km
options: from -5°C) range, 1 sensor cable.
Storage temperature range: 516.016.313 MZX SensorLaser™ Plus 2/2 – 2 km
-40°C to +80°C range, 2 sensor cables.
Operating humidity range: 516.016.333 MZX SensorLaser™ Plus 3/1 – 3 km
0% to 95% RH (2 channel options: range, 1 sensor cable.
15% to 85% RH) non condensing 516.016.334 MZX SensorLaser™ Plus 3/2 – 3 km
Dimensions (H x W x D): range, 2 sensor cables.
88 x 448 x 364 mm (19” rack) 516.016.314 MZX SensorLaser™ Plus 4/1 – 4 km
Weight: 9 kg range, 1 sensor cable.
Fibre types: MM 50/125 μm graded index MM 516.016.315 MZX SensorLaser™ Plus 4/2 – 4 km
62.5/125 μm graded index range, 2 sensor cables.
Dynamic range: 30 dB (2-way loss) 516.016.316 MZX SensorLaser™ Plus 8/1 – 8 km
Sensing temperature range: range, 1 sensor cable.
-273°C to +700°C depending on 516.016.317 MZX SensorLaser™ Plus 8/2 – 8 km
sensor coating range, 2 sensor cables.
Optical connector: E2000; 8° angled 516.016.318 MZX SensorLaser™ Plus Connection Set.
Number of channels: 1, 2 depending on channel option 516.016.319 MZX SensorLaser™ Plus iBox
Computer interface: USB, LAN 516.016.320 MZX SensorLaser™ Plus Relay Controller
Relay board: 4 inputs / 20 outputs Set.
Power supply: 10 V to 30 Vdc 516.016.321 MZX SensorLaser™ Plus Power Supply.
Power consumption: 15 W typically, at 20°C ambient 516.016.322 MZX SensorLaser™ Plus Safety Cable
temperature < 40 W (entire (per metre).
operating conditions) 516.016.322.C MZX SensorLaser™ Plus Safety
Measurement times: from 10s to 30s Connector.
Available spatial resolution settings: 516.016.323 MZX Steel Wire Armoured SensorLaser™
1 m; 1.5 m; 3 m; 5 m; 8 m Plus Cable (per metre).
Available measurement modes: 516.016.323.C MZX SensorLaser™ Plus Steel Connector.
Single ended/Dual ended; 516.016.324 MZX SensorLaser™ Plus Setting Tool.
including fibre break recovery 516.016.325 MZX SensorLaser™ Plus Relay Extension
Internal data storage capability: Set.
150 traces total 516.016.326 MZX SensorLaser™ Plus Zinc Plastic
Power Supply (option) operating conditions: Clamp Set. (PK 100)
0°C to +50°C; non condensing; 516.016.327 MZX SensorLaser™ Plus Steel Plastic
indoor use only Clamp Set. (PK 100)
Laser class (IEC 60825-1: 2001):1M 516.016.328 MZX SensorLaser™ Plus Steel Zinc Clamp
Set. (PK 100)
516.016.329 MZX SensorLaser™ Plus Stainless Steel
Clamp Set. (PK 100)
516.016.330 MZX SensorLaser™ Plus Spare Unit.
516.016.331 MZX SensorLaser™ Plus Demo Unit.
516.016.332 MZX SensorLaser™ Plus Demo Box.
12/13 Fire Catalogue Chapter 10 Page 27